Laai Tegniese Spesifikasies PDF af

Die MegSolid 80–125kW modulêre energiebergingskragomskakelingstelsel is beskikbaar met 80kW, 105kW en 125kW aangeslane WS-uitset. Dit is ontwerp vir kommersiële en industriële batteryenergiebergingsstelsels en ondersteun bidireksionele laai en ontlaai oor 'n wye GS-bedryfsspanningsbereik.

Met 'n doeltreffendheid van tot 98,71 TP3T, 'n omskakelingsvertraging van minder as 20 ms en ondersteuning vir 1001 TP3T enkelfasie ongelykbalanslading, lewer die stelsel buigsame en betroubare energieomskakeling. RS485-, CAN- en Ethernet-kommunikasie maak gerieflike integrasie met BMS en EMS moontlik, terwyl die modulêre 19-duim-ontwerp installasie en onderhoud vergemaklik.

400

Gegradeerde spanning (V)

98.7%

Max.efficiency

±1%

Voltage accuracy

THDi

<2%

THDV

3% (linear load)

Charge/discharge switching time (ms)

<20

Relative humidity

DC(battery)

Ons Kernwaardes

DC(battery)

Model

PMA080 | PMA0105 | PMA0125

Max. DC power (kW)

96 | 126 | 150

DC voltage range (V)

615~950Vdc(3W+PE)/650~950Vdc(3W+N+PE)

DC full load voltage range (V)

650-950Vdc(3W+PE)/680-950Vdc(3W+N+PE)+230

Max. DC current (A)

±150 | ±195 | ±230

Voltage stabilization accuracy

±1%

Current stabilization accuracy

±2%

AC(on-grid)

Rated AC power (kW)

80 | 105 | 125

Max. AC power (kWA)

96 | 126 | 150

Voltage scale

3W+PE or 3W+N+PE

Gegradeerde spanning (V)

400

Rated AC current (A)

115 | 150 | 180

Max. AC current (A)

138 | 180 | 216

Allowable grid voltage range (V)

400Vac±15%

Allowable grid frequency range (Hz)

50±2Hz/60±2Hz

Power factor adjustment range

-1 ~ +1

AC( off-grid)

Rated AC power (kW)

80 | 105 | 125

Max. output current (A)

138 | 180 | 216

Max. AC power (kWA)

96 | 126 | 150

Gegradeerde spanning (V)

230/400

Rated frequency (Hz)

50Hz/60Hz

Voltage accuracy

±1%

Frequency accuracy

(50Hz/60Hz ±0.1%)Hz

THDV

3% (linear load)

Unbalanced load capacity

Supports 100% single-phase unbalance

Oorlaaivermoë

≤110%,continuous ;≤120%,2min ;>120%,200ms

System

Max. efficiency

98.7%

Charge/discharge switching time (ms)

<20

Indringersbeskerming

IP20 (power compartment) IP6X (control compartment)

Relative humidity

<95%(non-condensing)

Operating temperature range (℃)

-30~+60 (>45 derating)

Max. operating altitude (m)

5000(>3000 derating)

Communication interface

RS485/CAN/Ethernet

BMS/EMS access

Ondersteun

Dimension W*D*H (mm)

483*680*174 19inch 4U 483*680*220 19inch 5U | 483*680*174 19inch 4U 483*680*220 19inch 5U | 483*680*174 19inch 4U 483*680*220 19inch 5U

Gewig (kg)

48(back wiring) 50(front wiring) | 48(back wiring) 50(front wiring) | 48(back wiring) 50(front wiring)

Kry jou MegSolid-energiebergingsoplossing binne 24 uur

Direk van 'n Vastestaat-batteryvervaardiger. Ontvang 'n pasgemaakte ESS-voorstel, ROI-ontleding en stelselaanbeveling van ons ingenieurspan.

Wat jy sal ontvang

Wêreldwyd Vertrou

UL, IEC, UN38.3, China Klassifikasiesamesetting, GB36276-2023, RoHS

Hot Modelle:

Toepassings:

Fabrieke · Sonplase · Mynbou · Eilande · Datasentrums

Vertel ons van jou projek — ons ontwerp die stelsel vir jou.

Seraphinite AcceleratorOptimized by Seraphinite Accelerator
Turns on site high speed to be attractive for people and search engines.