{"id":4516,"date":"2026-08-04T14:41:41","date_gmt":"2026-08-04T06:41:41","guid":{"rendered":"https:\/\/www.solidess.com\/?p=4516"},"modified":"2026-08-04T14:42:45","modified_gmt":"2026-08-04T06:42:45","slug":"waarom-n-bess-sy-kapasiteitstoets-sonder-n-alarm-druip","status":"publish","type":"post","link":"https:\/\/www.solidess.com\/af\/why-a-bess-fails-its-capacity-test-without-an-alarm\/","title":{"rendered":"Waarom 'n BESS sonder 'n alarm sy kapasiteitstoets misluk"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"4516\" class=\"elementor elementor-4516\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-bf4793c e-con-full auto-article-root e-flex e-con e-parent\" data-id=\"bf4793c\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c19f9202 auto-image elementor-widget elementor-widget-image\" data-id=\"c19f9202\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"1000\" height=\"1000\" src=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/Why-a-BESS-Fails-Its-Capacity-Test-Without-an-Alarm.png\" class=\"attachment-1536x1536 size-1536x1536 wp-image-4513\" alt=\"MegSolid-ingenieur ondersoek &#039;n mislukking van &#039;n BESS-kapasiteitstoets tydens terrein-aanvaardingstoetsing\" srcset=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/Why-a-BESS-Fails-Its-Capacity-Test-Without-an-Alarm.png 1000w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/Why-a-BESS-Fails-Its-Capacity-Test-Without-an-Alarm-300x300.png 300w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/Why-a-BESS-Fails-Its-Capacity-Test-Without-an-Alarm-150x150.png 150w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/Why-a-BESS-Fails-Its-Capacity-Test-Without-an-Alarm-768x768.png 768w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/Why-a-BESS-Fails-Its-Capacity-Test-Without-an-Alarm-600x600.png 600w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/Why-a-BESS-Fails-Its-Capacity-Test-Without-an-Alarm-100x100.png 100w\" sizes=\"(max-width: 1000px) 100vw, 1000px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-98a8953a auto-p elementor-widget elementor-widget-heading\" data-id=\"98a8953a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">A <strong>Mislukking van die BESS-kapasiteitstoets<\/strong> Sonder 'n aktiewe alarm bewys dit nie outomaties dat die battery gebrekkig is nie. MegSolid begin deur die gekontrakteerde energiedefinisie, begin- en stoptoestande, toetskrag, bylaste, meterligging en onbeskikbare toerusting met die opgeneemde BMS-, PCS- en inkomstemeterdata te vergelyk.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0afc020a auto-p elementor-widget elementor-widget-heading\" data-id=\"0afc020a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">'n Alarm bevestig dat 'n gekonfigureerde drempel of beskermingsre\u00ebl oortree is. Dit bevestig nie dat die stelsel die gewaarborgde wisselstroomenergie gelewer het nie. 'n Gesond uitziende HMI kan dus saam bestaan met 'n mislukte terrein-aanvaardingstoets wanneer die kontraktuele toetsgrense en bedryfsvoorwaardes nie in lyn is nie.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-acb74567 auto-p elementor-widget elementor-widget-heading\" data-id=\"acb74567\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\"><strong>In hierdie gids sal jy leer:<\/strong> hoe om die getoetste kWh-grens te definieer, sewe nie-alarm tekort oorsake te diagnoseer, die bewyse wat nodig is vir 'n verdedigbare hertoets te bewaar en die aanvaardingmetode in vergelykbare EPC RFQ-velde om te skakel.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-fa69fc29 elementor-tablet-align-center elementor-align-center auto-cta elementor-widget elementor-widget-button\" data-id=\"fa69fc29\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"#elementor-action%3Aaction%3Dpopup%3Aopen%26settings%3DeyJpZCI6Ijk0OCIsInRvZ2dsZSI6ZmFsc2V9\" target=\"_blank\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Versoek 'n BESS-kapasiteitstekort-oorsig<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1aa6aedd auto-h2 elementor-widget elementor-widget-heading\" data-id=\"1aa6aedd\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Die direkte antwoord: Geen alarm beteken nie volle kapasiteit nie<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0953a767 auto-p elementor-widget elementor-widget-heading\" data-id=\"0953a767\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Die toets kan sy energiedoelwit misloop, selfs wanneer elke komponent binne sy plaaslike bedryfsgrense bly.  Kapasiteit is 'n ge\u00efntegreerde resultaat oor tyd; alarms beskryf gewoonlik onmiddellike toestande. 'n Klein verskil in SOC-eindpunte, deurlopende HVAC-vraag of 'n meetgrens aan die verkeerde kant van die transformator kan ophoop tot 'n materi\u00eble tekort sonder om 'n enkele fout te veroorsaak.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6b6c3122 elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"6b6c3122\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">\ud83c\udfaf <strong>SOC eindpunte:<\/strong> Die toets het nie by die goedgekeurde boonste toestand begin nie of by die ooreengekome onderste toestand gestop nie.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">\u26a1 <strong>Meetgrens:<\/strong> Die energie van die DC-naamplaat is vergelyk met die netto AC-energie by die PCS, die transformator of die PCC-meter.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">\ud83c\udf21\ufe0f <strong>Bedryfsvoorwaardes:<\/strong> Temperatuur, kragvlak, spanningsgrense of terreinontrekking het die beskikbare venster verminder.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">\ud83c\udf00 <strong>Bykomende vraag:<\/strong> Afkoeling, pompe, beheerstelsels, brandbeskermingsisteme en transformators het energie binne die toetsgrense verbruik.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">\ud83d\udd0c <strong>Beskikbaarheid van toerusting:<\/strong> 'n string, rack, PCS-blok of bykomstigheidsubsisteem was voldoende beskikbaar om 'n reis te vermy, maar nie ten volle beskikbaar vir die toets nie.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">\u23f1\ufe0f <strong>Dataintegriteit:<\/strong> Meter-skaling, tekenkonvensie, monsternemingsinterval of klokafstemming het die ge\u00efntegreerde resultaat vervorm.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">\ud83e\uddea <strong>Toetsvoorbereiding:<\/strong> Balansering, termiese stabilisering, russtyd of volledige laai is nie voor ontlading bereik nie.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1266d940 auto-p elementor-widget elementor-widget-heading\" data-id=\"1266d940\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Kommissie moet verifieer en dokumenteer dat die ge\u00efnstalleerde stelsel aan die gedefinieerde doelwitte voldoen, nie net bevestig dat dit aangeskakel kan word nie. Daardie beginsel is ooreenkomstig met die <strong><a href=\"https:\/\/www.sandia.gov\/app\/uploads\/sites\/163\/2021\/09\/ESHB_Ch21_Commissioning_Schoenung.pdf\" target=\"_blank\" style=\"color:#61CE70\" rel=\"noopener\">DOE-handboek vir energiestoring: inbedryfstellingsriglyne<\/a><\/strong>, wat opdraggewing beskou as 'n beheerde bewyseproses wat gekoppel is aan projekvereistes.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-efb85088 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"efb85088\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Bepaal in watter kapasiteit die kontrak getoets word.<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-88a780ee auto-p elementor-widget elementor-widget-heading\" data-id=\"88a780ee\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Die woord kapasiteit is te vaag vir 'n slaag-\/mislukklausule. Die EPC moet die elektriese grens, energierigting, tydinterval, goedgekeurde SOC- of spannings-eindpunte, bykomende behandeling en omgewingsvoorwaardes definieer. Vir 'n wisselstroomleweringstoets is die gemeete energie die tydsintegraal van werklike krag by die genoemde meter; die meter en die tekenkonvensie moet voor die toets aangedui word.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f36e278a auto-table elementor-widget elementor-widget-text-editor\" data-id=\"f36e278a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"cea-table-wrap\"><table><thead><tr><th>Kapasiteitsgrens<\/th><th>Wat dit verteenwoordig<\/th><th>Waarom die waarde verander<\/th><\/tr><\/thead><tbody><tr><td>Sel- of rak-gelykstroomenergie<\/td><td>Energie binne die batterygrens<\/td><td>Sluit PCS, transformator en sommige bykomstigheidsverliese uit<\/td><\/tr><tr><td>PCS AC-terminale<\/td><td>Energie omgeskakel deur die PCS<\/td><td>Sluit battery en PCS-gedrag in, maar kan transformer en terrein-hulpmiddels uitsluit.<\/td><\/tr><tr><td>BESS-transformatormeter<\/td><td>Energie n\u00e1 omskakeling en transformator-effekte<\/td><td>Veranderings met transformatorverlies en die bykomstige aansluitpunt<\/td><\/tr><tr><td>Punt van gemeenskaplike koppeling<\/td><td>Netto-energie gelewer aan die terrein of netwerkgrens<\/td><td>Kan terreinlas, PV, bykomstighede en ander toerusting insluit, tensy ge\u00efsoleer<\/td><\/tr><tr><td>Naamplaatenergie<\/td><td>Gepubliseerde nominale of beoordeelde bergingswaarde<\/td><td>Nie outomaties gelyk aan bruikbare of gewaarborgde AC-aflewering nie<\/td><\/tr><\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6c03d841 auto-image elementor-widget elementor-widget-image\" data-id=\"6c03d841\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"1000\" height=\"750\" src=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/BESS-Capacity-Test-Measurement-Boundary.png\" class=\"attachment-1536x1536 size-1536x1536 wp-image-4514\" alt=\"BESS-kapasiteitstoets meetgrens vanaf battery-DC-energie deur PCS-transformatorbykomstighede en PCC-meter\" srcset=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/BESS-Capacity-Test-Measurement-Boundary.png 1000w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/BESS-Capacity-Test-Measurement-Boundary-300x225.png 300w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/BESS-Capacity-Test-Measurement-Boundary-768x576.png 768w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/BESS-Capacity-Test-Measurement-Boundary-600x450.png 600w\" sizes=\"(max-width: 1000px) 100vw, 1000px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-fd5ee868 auto-p elementor-widget elementor-widget-heading\" data-id=\"fd5ee868\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Voordat jy aanbiedings vergelyk, gebruik die <strong><a href=\"https:\/\/www.solidess.com\/af\/commercial-energy-storage-procurement\/\" target=\"_blank\" style=\"color:#61ce70\">Aanbestedingsgids vir kommersi\u00eble energieberging<\/a><\/strong> om elke bieder op dieselfde krag-, energie- en verantwoordelikheidsgrens te dwing. 'n Prysvergeliking is nie geldig wanneer een verskaffer nominale gelykstroomenergie kwoteer en 'n ander netto wisselstroomaflewering by die PCC aanvaar nie.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-52b71a3f auto-h2 elementor-widget elementor-widget-heading\" data-id=\"52b71a3f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Sewe oorsake van 'n BESS-kapasiteitstekort<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-63f9b961 auto-h3 elementor-widget elementor-widget-heading\" data-id=\"63f9b961\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">1. Die SOC-eindpunte was nie ekwivalent nie<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-37b4e189 auto-p elementor-widget elementor-widget-heading\" data-id=\"37b4e189\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Die vertoonde 100% SOC is 'n skatting wat deur die BMS-algoritme en goedgekeurde bedryfsgrense beheer word; dit is nie 'n bewys dat elke string 'n identiese elektrochemiese toestand bereik het nie. Net so kan die ontlading stop omdat een string sy spannings- of temperatuurlimiet bereik het voordat die werfskerm die nominale laer SOC bereik het. Vergelyk pak- en stringspannings, SOC, laaivoltooiingsstatus, balanstoestand en die eerste aktiewe limiet by albei eindpunte.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3af85149 auto-h3 elementor-widget elementor-widget-heading\" data-id=\"3af85149\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">2. Hulpbelasting is anders getel<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f7844d6e auto-p elementor-widget elementor-widget-heading\" data-id=\"f7844d6e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Lugversorging, vloeistofkoelpompe, beheerkrag, verwarmers, vragte van die brandstofstelsel en transformator-nulbelastingverliese kan binne of buite die gekose meetgrense val. Die kapasiteitsresultaat moet aandui of bruto BESS-uitset of netto gelewerde energie aanvaar word. Neem bykomstigheids-kW's deurgaans tydens die toets op in plaas daarvan om daarna 'n onbevestigde persentasie toe te pas.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-61d6e0f9 auto-h3 elementor-widget elementor-widget-heading\" data-id=\"61d6e0f9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">3. Toetskrag het die beskikbare energie verander<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8c43468a auto-p elementor-widget elementor-widget-heading\" data-id=\"8c43468a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">'n Kapasiteitstoets by een kragvlak kan nie as verteenwoordigend van elke afleweringsplig beskou word nie. 'n Ho\u00ebr stroom kan omskakelings- en weerstandsverliese verhoog, terwyl 'n toets by baie lae krag die blootstelling van statiese bykomstighede kan verleng. Spesifiseer 'n konstante kragprofiel, toleransieband, hellingsbehandeling en hoe periodes buite die band hanteer word.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2365a8c0 auto-h3 elementor-widget elementor-widget-heading\" data-id=\"2365a8c0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">4. Temperatuur- of termiese beheer het die venster verminder<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-25c3eec2 auto-p elementor-widget elementor-widget-heading\" data-id=\"25c3eec2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Die stelsel kan die laai- en ontlaaibeperkings versag of verskerp voordat 'n temperatuur ernstig genoeg raak om 'n afskakeling te veroorsaak. Neem die omgewingstemperatuur, verteenwoordigende sel- en koelmiddeltemperatuur of kas-temperatuur, die status van die termiese stelsel en die kragbeperkings van die BMS\/PCS op. 'n Toets wat begin is voordat die stelsel stabiele toestande bereik, is moeilik om te herhaal of te verdedig.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-787faaf1 auto-h3 elementor-widget elementor-widget-heading\" data-id=\"787faaf1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">5. 'n tou of kragblok was gedeeltelik onbeskikbaar<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1aae94e1 auto-p elementor-widget elementor-widget-heading\" data-id=\"1aae94e1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">'n losgekoppelde kabel, kontaktoestand, kommunikasie-uitsluiting of onderhoudsombypassing kan die beskikbare energie verminder sonder om die hele aanleg af te skakel. Die aanvaardingrekord moet die ge\u00efnstalleerde konfigurasie met die aanlynkonfigurasie in ooreenstemming bring aan die begin, gedurende die beperkende gebeurtenis en aan die einde van die ontlading.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-bef15759 auto-h3 elementor-widget elementor-widget-heading\" data-id=\"bef15759\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">6. Metering of tyd-uitlyning was verkeerd<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-299cdee3 auto-p elementor-widget elementor-widget-heading\" data-id=\"299cdee3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">'n Seinomkeer, 'n skaalingsfout tussen kW en W, 'n wanpas CT-verhouding, 'n datagaping of klokverskuiwing kan 'n geldige ontlading in 'n skynbare mislukking omskep. Vergelyk die inkomstramer met PCS- en EMS-neigings by 'n gemeenskaplike tydstempel. Die <strong><a href=\"https:\/\/www.solidess.com\/af\/bess-factory-acceptance-test-guide\/\" target=\"_blank\" style=\"color:#61ce70\">BESS-fabrieksaanvaardingstoets-getuienisgids<\/a><\/strong> Help om skaalvorming, handtekening en data-kettingkontroles voor terreintoetsing te verskuif.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-072dcff3 auto-h3 elementor-widget elementor-widget-heading\" data-id=\"072dcff3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">7. Voorvoorwaardeling en toetsvolgorde was onvolledig<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2ce1684c auto-p elementor-widget elementor-widget-heading\" data-id=\"2ce1684c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Die goedgekeurde prosedure moet die laaimetode, voltooiingskriteria, balanseringsgeleentheid, rusperiode, termiese stabilisering en voorafgaande diens definieer. As die stelsel na 'n onbeheerde uitstuur of onvolledige lading vir die toets aangebied word, is die resultaat nie direk vergelykbaar met die gekontrakteerde verwysingstoestand nie.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f1a58ff9 auto-image elementor-widget elementor-widget-image\" data-id=\"f1a58ff9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"1000\" height=\"750\" src=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/BESS-Capacity-Shortfall-Diagnostic-Matrix.png\" class=\"attachment-1536x1536 size-1536x1536 wp-image-4515\" alt=\"BESS-kapasiteitstekortdiagnostiese matriks wat simptome koppel aan meter, BMS, PCS en bykomstigheidsbewyse\" srcset=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/BESS-Capacity-Shortfall-Diagnostic-Matrix.png 1000w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/BESS-Capacity-Shortfall-Diagnostic-Matrix-300x225.png 300w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/BESS-Capacity-Shortfall-Diagnostic-Matrix-768x576.png 768w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/BESS-Capacity-Shortfall-Diagnostic-Matrix-600x450.png 600w\" sizes=\"(max-width: 1000px) 100vw, 1000px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0da5860e auto-h2 elementor-widget elementor-widget-heading\" data-id=\"0da5860e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Gebruik bewyse om toetsfoute van stelselbeperkings te onderskei<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-61ceb9d5 auto-p elementor-widget elementor-widget-heading\" data-id=\"61ceb9d5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Moenie begin deur SOC-limiete te verander, alarems te herstel of modules te vervang nie. Bewaar die oorspronklike l\u00eaers en identifiseer die eerste gebeurtenis wat krag, beskikbaarheid of die energie-venster verander het. Die minimum datastel is versoekte en gemeete AC-krag, die kontraktuele meter, BESS-SOC, battery spanning en stroom, stringbeskikbaarheid, BMS-laai-\/ontlaaibeperkings, PCS-beperkings, verteenwoordigende temperature, bykomstigheidsenergie en gesinchroniseerde gebeurtenislogboeke.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-544a133c auto-table elementor-widget elementor-widget-text-editor\" data-id=\"544a133c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"cea-table-wrap\"><table><thead><tr><th>Waargenome patroon<\/th><th>Bewyse om eers te kontroleer<\/th><th>Waarskynlike besluit<\/th><\/tr><\/thead><tbody><tr><td>Stabiele krag, vroe\u00eb ontladingstop<\/td><td>Eerste stringspanningslimiet, SOC-eindpunt, onbeskikbare strings<\/td><td>Bevestig dat die venster en die string bruikbaar is voordat weer getoets word.<\/td><\/tr><tr><td>Bruto PCS-energie slaag; PCC-energie misluk<\/td><td>Transformatorverlies, bykomstigheidsmeter en gelyktydige werklading op die terrein<\/td><td>Bepaal die meetgrens en netto-leweringsklousule<\/td><\/tr><tr><td>Krag neem geleidelik af<\/td><td>Sel-temperatuurverspreiding, koelmiddel- of lugvloei-status, BMS\/PCS-grense<\/td><td>Korrigeer die termiese toestand en herhaal in 'n goedgekeurde omgewing.<\/td><\/tr><tr><td>Meter totaal stem nie ooreen met EMS-neiging nie<\/td><td>CT-verhouding, teken, tydsone, steekproefgaps en meterkalibrasie<\/td><td>Valideer die instrumentasie voordat jy batteryfout verklaar.<\/td><\/tr><tr><td>Herhaalde toetse verskil na verskillende vorige pligte.<\/td><td>Voorvoorbereiding, rus tyd, laaivoltooiing en balanstoestand<\/td><td>Standaardiseer die volgorde en stel 'n reproduceerbare basislyn vas.<\/td><\/tr><\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-42e01286 auto-p elementor-widget elementor-widget-heading\" data-id=\"42e01286\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Prestasietoetsdata behoort die krag wat met die netwerk uitgewissel word, die aangevraagde krag en die SOC te identifiseer; bykomende AC\/DC-meting, bykomstigheidsverbruik en temperatuurdata verbeter die oplossing van die worteloorsaak. Hierdie bewyse-kategorie\u00eb word ook weerspie\u00ebl in die <strong><a href=\"https:\/\/www.cooperative.com\/programs-services\/bts\/access\/Documents\/NRECA-Advisory-BESS-Test-Performance-Guide-March-2022.pdf\" target=\"_blank\" style=\"color:#61CE70\" rel=\"noopener\">NRECA BESS prestasietoetsgids<\/a><\/strong>.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c61459e1 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"c61459e1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Neem die kapasiteitstoets op in die RFQ voordat die toekenning gemaak word.<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5663d6d2 auto-p elementor-widget elementor-widget-heading\" data-id=\"5663d6d2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">'n Aankoopspan het meer hefboomkrag voor die aankoopbestelling as n\u00e1 'n betwiste SAT. Heg 'n kapasiteitstoetskedule aan die RFQ vas en vereis dat elke bieder insluitinge, afwykings en aannames aandui. Die <strong><a href=\"https:\/\/www.solidess.com\/af\/ci-bess-inkooplys-2026\/\" target=\"_blank\" style=\"color:#61ce70\">C&amp;I BESS-inkoopkontrolelys<\/a><\/strong> kan gebruik word vir die bre\u00ebr kommersi\u00eble hersiening, terwyl die toetskedule hierdie spesifieke aanvaardinggrens besit.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-36de0098 elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"36de0098\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">\ud83d\udccd <strong>Meetpunt:<\/strong> Meeternaam, SLD-ligging, akkuraatheidsklas, CT\/PT-verhouding, kalibrasie en tekenkonvensie.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">\ud83d\udd0b <strong>Energiegrondslag:<\/strong> Nominal DC, bruikbare DC, bruto AC of netto AC gelewerde energie; begin van die lewensduur of 'n ander aangeduide toestand.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">\u2b06\ufe0f <strong>Beginvoorwaarde:<\/strong> Lading voltooiing, ho\u00eb SOC of spanningskriteria, balansering, stabilisering en toelaatbare rus tyd.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">\u2b07\ufe0f <strong>Stop-toestand:<\/strong> Laer SOC- of spanningskriteria, eerste beperkingsgebeurtenis, veiligheidsgrens en hantering van handmatige onderbreking.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">\u2699\ufe0f <strong>Kragprofiel:<\/strong> Bevelde kW, toleransie, hellings, pouses, reaktiewe kragtoestand en uitgeslote intervalle.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">\ud83c\udf21\ufe0f <strong>Omgewing:<\/strong> Omgewing- en batterytemperatuurbereik, hoogte, HVAC-toestand en goedgekeurde afgradere\u00ebls.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">\ud83c\udf00 <strong>Hulpverenigings:<\/strong> Ingeslote laste, aparte meter, bruto\/netto-berekening en stilstandbehandeling.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">\ud83d\udcca <strong>Datapakket:<\/strong> Raw-meterl\u00eaer, BMS\/PCS\/EMS-trends, gebeurtenislog, monsternemingsnelheid, tydstempels en verslag sjabloon.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">\u2705 <strong>Aanvaardingre\u00ebl:<\/strong> Teiken, toleransie, korreksiemetode, herexamenregte, verantwoordelike party en tekortaanvulling.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ba06b18e auto-h2 elementor-widget elementor-widget-heading\" data-id=\"ba06b18e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Pas die toetsgrens toe op MegSolid C&amp;I BESS-modelle<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-28c4cd14 auto-p elementor-widget elementor-widget-heading\" data-id=\"28c4cd14\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">MegSolid-produkbeoordelings verskaf die toerusting se beginpunt; hulle vervang nie 'n projekspesifieke bruikbare-energie-waarborg nie. Die bestelde kwotasie, die ondertekende datablad, BOM, SLD, beheerverklaring, waarborg en aanvaardingplan moet ooreenstem oor die presiese konfigurasie en toetsvoorwaardes.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7eae8be6 auto-table elementor-widget elementor-widget-text-editor\" data-id=\"7eae8be6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"cea-table-wrap\"><table><thead><tr><th>MegSolid verwysing<\/th><th>Geverifieerde gepubliseerde data<\/th><th>Kapasiteitstoets RFQ-aksie<\/th><\/tr><\/thead><tbody><tr><td>ESSA0100B-0215 buite-kas<\/td><td>100 kW beoordeelde AC-krag; 215,04 kWh nominale kapasiteit; 0,5C by 25\u00b0C; LFP-sel tipe<\/td><td>Moenie 215,04 kWh by die PCC belowe nie; definieer die bruikbare SOC-venster, bykomstighede, toetskrag en AC-metergrense.<\/td><\/tr><tr><td>261.24 kWh vloeistofgekoelde stelsel<\/td><td>261,24 kWh beoordeelde energie; 125 kVA beoordeelde wisselstroomkrag; hibriede vaste-toestand LFP-314Ah; maksimum stelseldoeltreffendheid 90%<\/td><td>Moenie maksimum stelseldoeltreffendheid as gewaarborgde RTE heretiketteer nie; versoek die projekaanvaardingwaarde en -voorwaardes<\/td><\/tr><tr><td>ESSA0050B-0100 buite-kas<\/td><td>50 kW beoordeelde wisselstroomkrag; 100,352 kWh nominale kapasiteit; 0,5C by 25\u00b0C; LFP-sel tipe<\/td><td>Gebruik dieselfde maatstaf en bykomstige grens wanneer die nominale twee-uurklas met die vereiste terreinlewering vergelyk word.<\/td><\/tr><\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5b075abc auto-p elementor-widget elementor-widget-heading\" data-id=\"5b075abc\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Vir die buitelugplatform, hersien die <strong><a href=\"https:\/\/www.solidess.com\/af\/product\/buitekas-energiebergingstelsel\/\" target=\"_blank\" style=\"color:#61ce70\">MegSolid ESSA-kastepesifikasies<\/a><\/strong> saam met die <strong><a href=\"https:\/\/www.solidess.com\/af\/hoe-om-n-100-kw-215-kwh-buitelug-bess-vir-n-kommersiele-en-industriele-ki-terrein-te-kies\/\" target=\"_blank\" style=\"color:#61ce70\">100 kW \/ 215 kWh BESS keuse-gids<\/a><\/strong>. Vir 'n vloeistofgekoelde alternatief, die <strong><a href=\"https:\/\/www.solidess.com\/af\/261kwh-vloeistofgekoelde-energiebergingstelsel-rvk-gids\/\" target=\"_blank\" style=\"color:#61ce70\">261.24 kWh vloeistofgekoelde BESS RFQ-gids<\/a><\/strong> hou stelseldoeltreffendheid, krag en aanvaardingveronderstellings geskei.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-64064676 auto-p elementor-widget elementor-widget-heading\" data-id=\"64064676\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Waar die projek 'n geverifieerde hibriede vaste-toestand-konfigurasie vereis, kan MegSolid die vereiste sel- en stelselbewyse hersien. Hibriede vaste-toestandargitektuur kan die blootstelling aan brandbare vloeistowwe verminder en die weerstand teen sommige interne foutverspreidingsmeganismes verbeter wanneer dit deur toetstoelewens van die bestelde konfigurasie ondersteun word. Dit maak nie die BESS brandbestand nie en verwyder nie die behoefte aan BMS-limiete, termiese beheermaatre\u00ebls, opsporing, onderdrukking en noodprosedures nie. Hersien die <strong><a href=\"https:\/\/www.solidess.com\/af\/vastestof-energibergingstelsels\/\" target=\"_blank\" style=\"color:#61ce70\">MegSolid-vasttoestand-energiebergingstelsels<\/a><\/strong> en die <strong><a href=\"https:\/\/www.solidess.com\/af\/solid-state-battery-thermal-runaway-12-checks-before-you-approve-a-bess\/\" target=\"_blank\" style=\"color:#61ce70\">12 termiese-ontsnapping-verifikasiekontroles<\/a><\/strong> sonder om soliede-toestand-eise na standaard LFP-modelle oor te dra.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-65a7ed6e auto-h2 elementor-widget elementor-widget-heading\" data-id=\"65a7ed6e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Stuur die regte bewyse vir 'n verdedigbare hertoetsing<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4ba4d426 auto-p elementor-widget elementor-widget-heading\" data-id=\"4ba4d426\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Stuur aan MegSolid die ondertekende kapasiteitsklousule, SLD, meterligging, bestelde model en BOM, inbedryfstellingsplan, rou meter-uitvoer, BMS\/PCS\/EMS-neigings, alarm- en gebeurtenislogboeke, bykomstigheids-kragdata, omgewings- en batterytemperature, aanvang- en stoptoestande, bevol\u00eb kW, waargenome tekort en vorige hertoetsgeskiedenis. Dit stel die ingenieursbeoordeling in staat om 'n kontraktuele wanpassing, instrumentasieprobleem, terreintoestand en toerustingbeperking te onderskei voordat korreksiewerk aanbeveel word.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b387a5ed elementor-tablet-align-center elementor-align-center auto-cta elementor-widget elementor-widget-button\" data-id=\"b387a5ed\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"#elementor-action%3Aaction%3Dpopup%3Aopen%26settings%3DeyJpZCI6Ijk0OCIsInRvZ2dsZSI6ZmFsc2V9\" target=\"_blank\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Stuur toetsdata na MegSolid<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-fe2f00e7 auto-p elementor-widget elementor-widget-heading\" data-id=\"fe2f00e7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Hierdie artikel verskaf 'n basiese diagnostiese en aanskaffingsraamwerk. Om die wysigbare BESS-kapasiteitstoets-aanvaardingwerkboek te ontvang\u2014insluitend die meetgrensskedule, energie-integrasievakke, gesinchroniseerde datalist, hertoetsrekord en RFQ-verantwoordelikheidsmatrix\u2014stuur 'n e-pos. <strong>sfhq2008@gmail.com<\/strong>. Sluit die projekland, BESS-krag en -energie, die gekose model, die kontraktuele meetpunt en die verwagte afleweringsdatum in.<\/p>\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-d2d015fa auto-faq e-flex e-con-boxed e-con e-child\" data-id=\"d2d015fa\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-10e57346 elementor-widget elementor-widget-heading\" data-id=\"10e57346\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">VGV<\/h2>\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-f03a4f50 e-con-full e-flex e-con e-child\" data-id=\"f03a4f50\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-d2e182f6 elementor-widget elementor-widget-n-accordion\" data-id=\"d2e182f6\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;default_state&quot;:&quot;all_collapsed&quot;,&quot;max_items_expended&quot;:&quot;one&quot;,&quot;n_accordion_animation_duration&quot;:{&quot;unit&quot;:&quot;ms&quot;,&quot;size&quot;:400,&quot;sizes&quot;:[]}}\" data-widget_type=\"nested-accordion.default\">\n\t\t\t\t\t\t\t<div class=\"e-n-accordion\" aria-label=\"Blokkiemusiekspelers. Maak skakels oop met Enter of Spasie, maak toe met Escape, en navigeer met Pyltjiesleutels\">\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-3530\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"1\" tabindex=\"0\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-3530\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Wat behoort 'n BESS-kapasiteitstoetskontrak te definieer? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3530\" class=\"elementor-element elementor-element-a8bcb8b2 e-con-full e-flex e-con e-child\" data-id=\"a8bcb8b2\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3530\" class=\"elementor-element elementor-element-6f1fcd74 e-con-full e-flex e-con e-child\" data-id=\"6f1fcd74\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-958c26b9 elementor-widget elementor-widget-heading\" data-id=\"958c26b9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Definieer die energiegrondslag, meter en SLD-ligging, begin- en stoptoestande, konstante-kragprofiel, temperatuurbereik, bykomende behandeling, datal\u00eaers, pasverdraagsaamheid, korreksiemetode, hertoetsregte en kommersi\u00eble remedie.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-3531\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"2\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-3531\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Kan 'n BESS sy kapasiteitstoets misluk sonder 'n aktiewe alarm? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3531\" class=\"elementor-element elementor-element-1f843441 e-con-full e-flex e-con e-child\" data-id=\"1f843441\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3531\" class=\"elementor-element elementor-element-0219d8b3 e-con-full e-flex e-con e-child\" data-id=\"0219d8b3\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-228368e2 elementor-widget elementor-widget-heading\" data-id=\"228368e2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Ja. SOC-eindpunte, netto bykomstigheidsverbruik, meterposisie, afgradering, onbeskikbare stringe, kalibrasie of onvolledige voorvoorwaardering kan die gemeete energie verminder sonder om 'n gekonfigureerde foutdrempel te oorskry.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-3532\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"3\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-3532\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Moet kapasiteit op die gelykstroom- of wisselstroomkant gemeet word? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3532\" class=\"elementor-element elementor-element-7af34d79 e-con-full e-flex e-con e-child\" data-id=\"7af34d79\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3532\" class=\"elementor-element elementor-element-1d96ffe4 e-con-full e-flex e-con e-child\" data-id=\"1d96ffe4\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-912b6f39 elementor-widget elementor-widget-heading\" data-id=\"912b6f39\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Gebruik die grens wat in die kontrak genoem word. 'n terreinleweringsgarantie benodig gewoonlik 'n ge\u00efdentifiseerde AC-meter, terwyl diagnostiese toetse ook DC-battery- en PCS-metings kan gebruik om verliese en beperkings te onderskei.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-3533\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"4\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-3533\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Moet die bykomstige krag van BESS van die gelewerde energie afgetrek word? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3533\" class=\"elementor-element elementor-element-af9a2bd9 e-con-full e-flex e-con e-child\" data-id=\"af9a2bd9\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3533\" class=\"elementor-element elementor-element-1dd983ac e-con-full e-flex e-con e-child\" data-id=\"1dd983ac\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-40d92cfd elementor-widget elementor-widget-heading\" data-id=\"40d92cfd\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Slegs volgens die goedgekeurde bruto- of netto-grens. Gee aan watter verkoeling-, beheer-, brandbeskermingsstelsel-, verwarmer-, pomp- en transformatorlaste in die berekening ingesluit is en meet hulle tydens die toets waar dit prakties moontlik is.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-3534\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"5\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-3534\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Is die vertoonde SOC voldoende om die kapasiteitstoets-eindpunte te bewys? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3534\" class=\"elementor-element elementor-element-957fcc64 e-con-full e-flex e-con e-child\" data-id=\"957fcc64\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3534\" class=\"elementor-element elementor-element-a5dc833e e-con-full e-flex e-con e-child\" data-id=\"a5dc833e\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-922c016e elementor-widget elementor-widget-heading\" data-id=\"922c016e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Neen. Dokumenteer SOC saam met pakket- en stringspanning, stroom, laaivoltooiingsstaat, eerste beperkingsvoorwaarde, balansstatus en aktiewe BMS- of PCS-limiete by albei eindpunte.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-3535\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"6\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-3535\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Watter data moet n\u00e1 'n mislukte kapasiteitstoets bewaar word? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3535\" class=\"elementor-element elementor-element-c85db0c5 e-con-full e-flex e-con e-child\" data-id=\"c85db0c5\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3535\" class=\"elementor-element elementor-element-03772c61 e-con-full e-flex e-con e-child\" data-id=\"03772c61\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-237b4c5c elementor-widget elementor-widget-heading\" data-id=\"237b4c5c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Bewaar die rou kontraktuele meter-uitvoer, die aangevraagde en gemete krag, BMS- en PCS-grense, SOC, battery spanning en stroom, stringbeskikbaarheid, temperature, bykomstigheidsmag, alarms, gebeure en gesinchroniseerde tydstempels.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-3536\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"7\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-3536\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Wanneer moet 'n EPC 'n BESS-kapasiteitstoets herhaal? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3536\" class=\"elementor-element elementor-element-d6d27e26 e-con-full e-flex e-con e-child\" data-id=\"d6d27e26\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3536\" class=\"elementor-element elementor-element-8e06363d e-con-full e-flex e-con e-child\" data-id=\"8e06363d\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-126301d0 elementor-widget elementor-widget-heading\" data-id=\"126301d0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Herhaal dit nadat die oorsaak van die ongeldige of mislukte resultaat gedokumenteer is, die korrektiewe aksie voltooi is, die instrumentering geverifieer is en die goedgekeurde voorsorg- en omgewingsvereistes gereproduseer kan word.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-3537\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"8\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-3537\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Is nominale kWh gelyk aan bruikbare AC-energie? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3537\" class=\"elementor-element elementor-element-d978133b e-con-full e-flex e-con e-child\" data-id=\"d978133b\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3537\" class=\"elementor-element elementor-element-0ad05aa4 e-con-full e-flex e-con e-child\" data-id=\"0ad05aa4\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-3814d4c7 elementor-widget elementor-widget-heading\" data-id=\"3814d4c7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Nee. Nominale batterystroomenergie sluit nie outomaties die goedgekeurde SOC-venster, omskakeling- en transformatoreffekte, bykomstighede, reserwe, temperatuurtoestande, beskikbaarheid of einde-van-leeftydvereiste in nie.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-3538\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"9\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-3538\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Garanteer die ESSA0100B-0215 215,04 kWh by die PCC? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3538\" class=\"elementor-element elementor-element-69bc41fd e-con-full e-flex e-con e-child\" data-id=\"69bc41fd\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3538\" class=\"elementor-element elementor-element-fff99bb3 e-con-full e-flex e-con e-child\" data-id=\"fff99bb3\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-14166a50 elementor-widget elementor-widget-heading\" data-id=\"14166a50\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Nee. Die gepubliseerde 215,04 kWh-waarde is die nominale kapasiteit. Enige gewaarborgde PCC-lewering moet afsonderlik aangedui word met die metergrens, SOC-venster, toetskrag, bykomstigheidsbehandeling, voorwaardes en toleransie.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-3539\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"10\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-3539\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Wat moet 'n koper aan MegSolid stuur vir 'n oorsig van kapasiteitstekort? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3539\" class=\"elementor-element elementor-element-3a2b1d54 e-con-full e-flex e-con e-child\" data-id=\"3a2b1d54\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3539\" class=\"elementor-element elementor-element-d2174c79 e-con-full e-flex e-con e-child\" data-id=\"d2174c79\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-d0ce8a94 elementor-widget elementor-widget-heading\" data-id=\"d0ce8a94\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Stuur die ondertekende toeklousule, SLD, bestelde model en BOM, meterbesonderhede, rou tendense, bykomstigheidsdata, temperature, begin- en stoprekords, bevol\u00eb krag, waargenome energie en hertoetsgeskiedenis.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-35310\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"11\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-35310\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Wat is 'n BESS-kapasiteitstoetsmislukking? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-35310\" class=\"elementor-element elementor-element-1ee043c9 e-con-full e-flex e-con e-child\" data-id=\"1ee043c9\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-35310\" class=\"elementor-element elementor-element-c20ec83e e-con-full e-flex e-con e-child\" data-id=\"c20ec83e\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-cd323b89 elementor-widget elementor-widget-heading\" data-id=\"cd323b89\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">'n BESS-kapasiteitstoetsfout vind plaas wanneer die gemeete energie onder die goedgekeurde prosedure en grense nie aan die kontraktuele teiken of toleransie voldoen nie, selfs al bly die stelsel operasioneel en wys geen foutalarm nie.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-35311\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"12\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-35311\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Waarom kan die bruikbare BESS-energie laer wees as die naamplaatkapasiteit? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-35311\" class=\"elementor-element elementor-element-026f2cd3 e-con-full e-flex e-con e-child\" data-id=\"026f2cd3\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-35311\" class=\"elementor-element elementor-element-c1315a46 e-con-full e-flex e-con e-child\" data-id=\"c1315a46\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-4740853f elementor-widget elementor-widget-heading\" data-id=\"4740853f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Gebruikbare energie kan laer wees omdat die naamplaatkapasiteit verminder word deur die goedgekeurde SOC-venster, omskakeling- en transformatoreffekte, bykomstigheidsverbruik, reserwe-vereistes, temperatuurbeperkings, onbeskikbare toerusting en die gekose meetgrens.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-35312\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"13\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-35312\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Hoe ondersoek MegSolid 'n tekort aan BESS-kapasiteit? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-35312\" class=\"elementor-element elementor-element-195c7bb6 e-con-full e-flex e-con e-child\" data-id=\"195c7bb6\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-35312\" class=\"elementor-element elementor-element-3e87db52 e-con-full e-flex e-con e-child\" data-id=\"3e87db52\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-de408edd elementor-widget elementor-widget-heading\" data-id=\"de408edd\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">MegSolid versoen die kontrak en SLD met gesinchroniseerde meter-, BMS-, PCS-, EMS-, temperatuur-, bykomstigheids- en beskikbaarheidsdata, identifiseer die eerste beperkende gebeurtenis en definieer die bewyse wat nodig is vir korrektiewe optrede of 'n beheerde hertoets.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Diagnoseer 'n BESS-kapasiteitstoetsfout deur SOC-eindpunte, bykomstigheidslaste, temperatuur, kragvlak, onbeskikbare stringe en meetgrense te skei voordat die stelsel aanvaar of verwerp word.<\/p>","protected":false},"author":4,"featured_media":4513,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"_joinchat":[],"footnotes":""},"categories":[27,1],"tags":[239,236,235,224,234,237,31,36,238],"class_list":["post-4516","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-news","category-bess","tag-battery-capacity-testing","tag-bess-capacity-shortfall","tag-bess-capacity-test-failure","tag-bess-commissioning","tag-bess-sat","tag-bess-site-acceptance-test","tag-ci-energy-storage","tag-MegSolid","tag-usable-ac-energy"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.solidess.com\/af\/wp-json\/wp\/v2\/posts\/4516","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.solidess.com\/af\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.solidess.com\/af\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.solidess.com\/af\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/www.solidess.com\/af\/wp-json\/wp\/v2\/comments?post=4516"}],"version-history":[{"count":7,"href":"https:\/\/www.solidess.com\/af\/wp-json\/wp\/v2\/posts\/4516\/revisions"}],"predecessor-version":[{"id":4523,"href":"https:\/\/www.solidess.com\/af\/wp-json\/wp\/v2\/posts\/4516\/revisions\/4523"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.solidess.com\/af\/wp-json\/wp\/v2\/media\/4513"}],"wp:attachment":[{"href":"https:\/\/www.solidess.com\/af\/wp-json\/wp\/v2\/media?parent=4516"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.solidess.com\/af\/wp-json\/wp\/v2\/categories?post=4516"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.solidess.com\/af\/wp-json\/wp\/v2\/tags?post=4516"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}