{"id":5173,"date":"2026-09-02T09:38:13","date_gmt":"2026-09-02T01:38:13","guid":{"rendered":"https:\/\/www.solidess.com\/?p=5173"},"modified":"2026-09-02T09:38:13","modified_gmt":"2026-09-02T01:38:13","slug":"mexico-fabriek-bess-cenace-vinnige-studieleer","status":"publish","type":"post","link":"https:\/\/www.solidess.com\/af\/mexico-factory-bess-cenace-quick-study-file\/","title":{"rendered":"Mexico Fabrieks-BESS: CENACE Vinnestudie-l\u00eaer"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"5173\" class=\"elementor elementor-5173\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-bf4793c e-con-full auto-article-root e-flex e-con e-parent\" data-id=\"bf4793c\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c888831e auto-p elementor-widget elementor-widget-heading\" data-id=\"c888831e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Die toevoeging van BESS by 'n bestaande fabriek in Mexiko begin met 'n beoordeling van tegniese wysigings. CENACE besluit dan of die verandering nuwe aansluitingsstudies vereis.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0f93d0ee auto-p elementor-widget elementor-widget-heading\" data-id=\"0f93d0ee\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\"><strong>Wat die koper moet weet:<\/strong><\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a9fe2aa2 elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"a9fe2aa2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>Route:<\/strong> CENACE ken die studie toe nadat die tegniese wysiging hersien is.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>Laaibeperking:<\/strong> Fabrieksvraag plus BESS-laai moet binne die gekontrakteerde las bly.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>Uitvoerlimiet:<\/strong> SAEE-CC-afvoer bly agter die aansluitpunt en volg die lewendige fabrieksvraag.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>Vrystellingshek:<\/strong> die finale kas en PCS bly oop totdat die roete, kW\/kVA-limiete en hersiene SLD ooreenstem.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-25407fd3 auto-image elementor-widget elementor-widget-image\" data-id=\"25407fd3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"920\" height=\"920\" src=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Mexico-Factory-BESS-CENACE-Technical-Modification.png\" class=\"attachment-1536x1536 size-1536x1536 wp-image-5170\" alt=\"MegSolid ESSA0100B-0215 by &#039;n elektriese terrein van &#039;n fabriek in Mexiko met &#039;n CENACE-tegniese wysigingsl\u00eaer en PCC-toerusting\" srcset=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Mexico-Factory-BESS-CENACE-Technical-Modification.png 920w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Mexico-Factory-BESS-CENACE-Technical-Modification-300x300.png 300w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Mexico-Factory-BESS-CENACE-Technical-Modification-150x150.png 150w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Mexico-Factory-BESS-CENACE-Technical-Modification-768x768.png 768w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Mexico-Factory-BESS-CENACE-Technical-Modification-12x12.png 12w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Mexico-Factory-BESS-CENACE-Technical-Modification-600x600.png 600w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Mexico-Factory-BESS-CENACE-Technical-Modification-100x100.png 100w\" sizes=\"(max-width: 920px) 100vw, 920px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e3cccb22 auto-p elementor-widget elementor-widget-heading\" data-id=\"e3cccb22\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Produkontrolling kan steeds voortgaan. Begin met die <strong><a href=\"https:\/\/www.solidess.com\/af\/battery-energy-storage-system-design-ci-sites\/\" target=\"_blank\" style=\"color:#61ce70\">C&amp;I-battery-energie-opbergstelselontwerp<\/a><\/strong>, kontroleer die werklike <strong><a href=\"https:\/\/www.solidess.com\/af\/400-v-bss-verbinding-bestaande-skakelbord\/\" target=\"_blank\" style=\"color:#61ce70\">400 V-skakelbordverbinding<\/a><\/strong>, en herstel die <strong><a href=\"https:\/\/www.solidess.com\/af\/hoe-om-bess-nul-uitvoerbeheer-by-die-pcc-te-spesifiseer\/\" target=\"_blank\" style=\"color:#61ce70\">nul-uitvoerkontrolepunt<\/a><\/strong> op die SLD.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-bc046b9e auto-p elementor-widget elementor-widget-heading\" data-id=\"bc046b9e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Die regsverwysing is die <a href=\"https:\/\/dof.gob.mx\/nota_detalle_popup.php?codigo=5785045\" target=\"_blank\" rel=\"noopener\">CNE-ooreenkoms gepubliseer in die Diario Oficial de la Federaci\u00f3n op 16 April 2026<\/a>. Dit gebruik SAEE-CC vir berging wat verband hou met 'n lasentrum. Sommige regeringsskerms vertoon steeds SAE-CC, dus moet die indieningspan die etiket gebruik wat deur die huidige indieningsportaal vertoon word, terwyl die regsterm in die tegniese rekord behou word.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-feb77b88 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"feb77b88\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Tegniese wysiging kom voor die studienaam<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-41a5b4e4 auto-p elementor-widget elementor-widget-heading\" data-id=\"41a5b4e4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Artikel 4.6.5 stuur 'n bestaande lasentrum wat stoorruimte byvoeg deur die tegniese wysigingsproses. 'n Nuwe lasentrum wat met stoorruimte ontwerp is, vereis 'n impakstudie en 'n installasiestudie. Vir 'n bestaande lasentrum wat aan die RNT gekoppel is, beveel artikel 4.5 sy verteenwoordiger aan om CENACE in kennis te stel, wat dan die behoefte aan nuwe studies beoordeel.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-fb2e7437 auto-table elementor-widget elementor-widget-text-editor\" data-id=\"fb2e7437\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"cea-table-wrap\"><table><thead><tr><th>Fabriekstoestand<\/th><th>Regulerende beginpunt<\/th><th>Wat die koper kan vrylaat<\/th><\/tr><\/thead><tbody><tr><td>Bestaande bedryfslasentrum voeg SAEE-CC by<\/td><td>Kennisgewing van tegniese wysiging en CENACE-evaluering<\/td><td>Voorlopige produkfamilie en beheerde tegniese data; belowe nie 'n studie-uitsondering nie<\/td><\/tr><tr><td>Nuwe lasentrum met berging in die oorspronklike ontwerp<\/td><td>Impakstudie plus installasiestudie<\/td><td>Studieontwerpbasis, voorgestelde toerustingband en verbindingsdata<\/td><\/tr><tr><td>Bedryfswerf wat ook die gekontrakteerde vraag verhoog<\/td><td>Tegniese wysiging plus die toepaslike aanvraagwysigingsproses<\/td><td>Vrystelling van toerusting slegs nadat die nuwe aanvraaggrondslag en die verbindingspad bevestig is.<\/td><\/tr><tr><td>Groepeer bestaande lasentrums wat berging integreer<\/td><td>Die 2026-ooreenkoms identifiseer 'n Estudio R\u00e1pido-roete vir die gegroepeerde saak.<\/td><td>Projekspesifieke roete en aansluitpunt deur CENACE bevestig<\/td><\/tr><\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c3db66b4 auto-image elementor-widget elementor-widget-image\" data-id=\"c3db66b4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"1100\" height=\"825\" src=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/CENACE-Route-for-an-Existing-Load-Center.png\" class=\"attachment-1536x1536 size-1536x1536 wp-image-5171\" alt=\"CENACE-besluitpad vir &#039;n bestaande Mexikaanse lasentrum wat SAEE-CC byvoeg, vanaf tegniese wysiging tot studie-oorsig\" srcset=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/CENACE-Route-for-an-Existing-Load-Center.png 1100w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/CENACE-Route-for-an-Existing-Load-Center-300x225.png 300w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/CENACE-Route-for-an-Existing-Load-Center-1024x768.png 1024w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/CENACE-Route-for-an-Existing-Load-Center-768x576.png 768w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/CENACE-Route-for-an-Existing-Load-Center-16x12.png 16w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/CENACE-Route-for-an-Existing-Load-Center-600x450.png 600w\" sizes=\"(max-width: 1100px) 100vw, 1100px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-aa9c77e8 auto-p elementor-widget elementor-widget-heading\" data-id=\"aa9c77e8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Die ooreenkoms ken uitdruklik 'n Estudio R\u00e1pido toe aan die geval van 'n gegroepeerde bestaande-lasentrum. 'n Enkele fabriek kan daardie roete nie in sy program kopieer sonder bevestiging deur CENACE nie.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-af83a1a7 auto-p elementor-widget elementor-widget-heading\" data-id=\"af83a1a7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">SIASIC lys aanduidende, impak-, installasie-, kragkwaliteit-, validasie- en vinnige impakstudies. Hierdie name beskryf die ontleding wat CENACE n\u00e1 roetebepaling uitvoer. Hou een houpunt in die projekskedule: <strong>CENACE-studievereiste en -roete per skrywe bevestig.<\/strong><\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7abed6a8 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"7abed6a8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Bepaal die bedryfsomvang voordat jy die kabinet benoem.<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4d50309e auto-p elementor-widget elementor-widget-heading\" data-id=\"4d50309e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Gebruik dieselfde vier waardes op die SLD, bedryfsnarratief en EMS-instellingsblad:<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8c973b66 elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"8c973b66\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">die gekontrakteerde las by die aansluitpunt;<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">die laagste geloofwaardige fasiliteitsvraag gedurende 'n laaivenster;<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">die maksimum SAEE-laaivermo\u00eb;<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">die maksimum SAEE-ontladingsbevel wat steeds uitvoer voorkom.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d3cfb611 auto-p elementor-widget elementor-widget-heading\" data-id=\"d3cfb611\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Die April 2026-re\u00ebls bepaal dat SAEE-CC-krag nie die vraag by die lasentrum mag oorskry nie, dat die eenheid vanaf die aansluitpunt gelaai word, en dat laai nie die lasentrum bo sy gekontrakteerde las mag stoot nie. Dieselfde re\u00ebls verbied inspuiting in die RNT of RGD by die aansluitpunt.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-10fac3fe auto-p elementor-widget elementor-widget-heading\" data-id=\"10fac3fe\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\"><strong>Laaiplafon<\/strong><\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0bab06f6 auto-p elementor-widget elementor-widget-heading\" data-id=\"0bab06f6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\"><strong>Aanlegvraag + SAEE-afrekeningskrag \u2264 gekontrakteerde las by die aansluitpunt<\/strong><\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-45f3f2de auto-p elementor-widget elementor-widget-heading\" data-id=\"45f3f2de\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\"><strong>Ontslagplafon<\/strong><\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-010ecb9f auto-p elementor-widget elementor-widget-heading\" data-id=\"010ecb9f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\"><strong>SAEE-aflaaibedrag \u2264 gemeet fasiliteitsvraag minus die ooreengekome invoer-bias<\/strong><\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6b0a13ff auto-p elementor-widget elementor-widget-heading\" data-id=\"6b0a13ff\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Die invoervoorkeur gee die beheerder ruimte vir meterlatensie, lasstappe en PCS-reaksie. Die projekingenieur stel daardie waarde vas op grond van die meteropdateringsnelheid, die beheerdooieband en die netwerkvereiste. 'n Brosjure kan dit nie verskaf nie.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0e239748 auto-p elementor-widget elementor-widget-heading\" data-id=\"0e239748\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Kragtekens het ook een konvensie nodig. Byvoorbeeld kan positiewe PCC-krag invoer beteken en negatiewe krag uitvoer beteken. Die EMS-puntelys, studiemodel, FAT-prosedure en SAT-neiging moet almal dieselfde teken volg. Om een CT om te keer, kan 'n korrekte beheergelyking in volgehoue uitvoer verander.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b1381879 auto-image elementor-widget elementor-widget-image\" data-id=\"b1381879\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"1080\" height=\"810\" src=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Mexico-BESS-Operating-Envelope-at-the-PCC.png\" class=\"attachment-1536x1536 size-1536x1536 wp-image-5172\" alt=\"MegSolid ESSA0100B-0215 met BESS-laaiplafon, ontlaaiplafon en SAT-kontroles by &#039;n PCC in &#039;n fabriek in Mexiko\" srcset=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Mexico-BESS-Operating-Envelope-at-the-PCC.png 1080w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Mexico-BESS-Operating-Envelope-at-the-PCC-300x225.png 300w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Mexico-BESS-Operating-Envelope-at-the-PCC-1024x768.png 1024w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Mexico-BESS-Operating-Envelope-at-the-PCC-768x576.png 768w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Mexico-BESS-Operating-Envelope-at-the-PCC-16x12.png 16w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Mexico-BESS-Operating-Envelope-at-the-PCC-600x450.png 600w\" sizes=\"(max-width: 1080px) 100vw, 1080px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c0ba6462 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"c0ba6462\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Monterrey-fabrieksvoorbeeld: Die 80 kW-marge dek slegs die eerste skerm.<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-28a9bbf6 auto-p elementor-widget elementor-widget-heading\" data-id=\"28a9bbf6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Oorweeg 'n hipotetiese Monterrey-fabriek met 'n gekontrakteerde las van 1 200 kW. Die geverifieerde naglas daal gedurende die beplande laaiperiode tot 620 kW. Die voorlopige ontwerp gebruik vyf ESSA0100B-0215-kaste, wat 'n gekombineerde gepubliseerde beoordeling van 500 kW \/ 1 075,2 kWh by 400 V gee.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9ca4eea4 auto-p elementor-widget elementor-widget-heading\" data-id=\"9ca4eea4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">By die voorgestelde 500 kW-laaibeveling:<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-50dc64e3 auto-p elementor-widget elementor-widget-heading\" data-id=\"50dc64e3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\"><strong>620 kW fasiliteitsvraag + 500 kW laai = 1 120 kW totale invoer<\/strong><\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6b8aaa2b auto-p elementor-widget elementor-widget-heading\" data-id=\"6b8aaa2b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\"><strong>Voorlopige laaivergelyking = 1 200 kW \u2212 1 120 kW = 80 kW<\/strong><\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-beb4d3b7 auto-p elementor-widget elementor-widget-heading\" data-id=\"beb4d3b7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Die 80 kW-syfer kom van een bedryfs punt. 'n Chiller-start of 'n verlengde produksielopie kan dit verbruik voordat die beheerunit die volgende meteropdatering ontvang. Die EMS trek dus laadkrag af van die lewendige PCC-vraag en laat 'n alarm afgaan as die battery nie sy teikenenergie binne die toegelaatde venster kan herstel nie.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9b1e9d46 auto-p elementor-widget elementor-widget-heading\" data-id=\"9b1e9d46\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Die fabriek stel ook 'n 450 kW piekverminderingbevel voor. Op 'n oomblik wanneer die terreinvraag tot 300 kW daal, kan die PCS nie voortgaan om teen 450 kW te ontlaai sonder om te uitvoer nie. Geslote-lusbeheer moet die uitset vinnig genoeg verminder om die ooreengekome invoer-neiging te handhaaf. Die studiemodel benodig die metervertraging, beheerder-skandeer tyd, PCS-hellingslimiet en kommunikasieverlies-aksie om daardie geval te toets.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0e6ac5ee auto-p elementor-widget elementor-widget-heading\" data-id=\"0e6ac5ee\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Vyf 100 kW-kaste vertoon in hierdie voorbeeld die aktiewe krag-naambordskerm. Die transformator, skakelbord, foutvlak, beskermingsinstellings en geleierroete benodig nog projekberekeninge. Gelyktydige werking van al vyf eenhede hang ook af van temperatuur, hoogte, kragfaktor, beskikbaarheid en die beheerde modeldata.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a58ec679 auto-p elementor-widget elementor-widget-heading\" data-id=\"a58ec679\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\"><strong>Kontroleer die bedryfsomvang van Mexico SAEE-CC<\/strong><\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-be657d4d auto-p elementor-widget elementor-widget-heading\" data-id=\"be657d4d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Verskaf die gekontrakteerde las, minimum- en maksimumfasiliteitsvraag, die voorgestelde BESS kW\/kVA\/kWh, die PCC-ligging en die laaivenster. Die hersiening lewer 'n voorlopige laadlimiet, 'n geen-uitvoer-grens en die ontbrekende data wat die vrystelling van toerusting verhinder.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-415056b5 elementor-tablet-align-center elementor-align-center auto-cta elementor-widget elementor-widget-button\" data-id=\"415056b5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"#elementor-action%3Aaction%3Dpopup%3Aopen%26settings%3DeyJpZCI6Ijk0OCIsInRvZ2dsZSI6ZmFsc2V9\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Oorsien die bedryfsomvang van Mexiko<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f382072a auto-h2 elementor-widget elementor-widget-heading\" data-id=\"f382072a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Bou die l\u00eaer rondom die vrae wat CENACE moet toets.<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-79786802 auto-p elementor-widget elementor-widget-heading\" data-id=\"79786802\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">'n Tegniese wysigingsl\u00eaer moet die fabriek voor en n\u00e1 die byvoeging van die battery wys. 'n Katalogus, 'n elektriese rekening en 'n ou enkellynskema laat die hersiener die verandering rekonstrueer en lei gewoonlik tot 'n ander dokumentsversoek.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5773a1f6 auto-table elementor-widget elementor-widget-text-editor\" data-id=\"5773a1f6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"cea-table-wrap\"><table><thead><tr><th>L\u00eaeritem<\/th><th>Ingenieursvraag wat dit beantwoord<\/th><th>Normale bron<\/th><\/tr><\/thead><tbody><tr><td>Bestaande aansluiting en gekontrakteerde lasrekord<\/td><td>Watter elektriese grens funksioneer reeds, en watter vraag is aanvaar?<\/td><td>Eienaar, verskaffer of verteenwoordiger van 'n gekwalifiseerde gebruiker<\/td><\/tr><tr><td>Bestaande en voorgestelde enkellynskemas<\/td><td>Waar koppel die SAEE aan, en wat verander by die aansluitingspunt?<\/td><td>Plaaslike elektriese ingenieur of EPC<\/td><\/tr><tr><td>Minimum-, medium- en maksimumvraaggevalle<\/td><td>Kan die SAEE laai en ontlaai sonder om die goedgekeurde netwerkgrens te verander?<\/td><td>Intervalmeterdata en die eienaar se produksieplan<\/td><\/tr><tr><td>SAEE-graderingblad<\/td><td>Watter aktiewe krag, skynbare krag, energie, spanning en kragfaktorbereik kom in die model voor?<\/td><td>MegSolid beheerde datablad en PCS-skedule<\/td><\/tr><tr><td>Laaigrafiek, ontlaaigrafiek en SOC-skedule<\/td><td>Wanneer onttrek die stelsel krag, hoe lank ontlaai dit en watter reserwe bly oor?<\/td><td>Eienaar se bedryfsinstruksies en funksionele beskrywing van die EMS<\/td><\/tr><tr><td>Rampa- en beheergegewens<\/td><td>Hoe vinnig kan die uitset verander na 'n lasstap of 'n CENACE-instruksie?<\/td><td>PCS-data en EMS-beheerspesifikasie<\/td><\/tr><tr><td>Kortsluit- en beskermingsmodel<\/td><td>Watter huidige bydrae en reisdraai bereik die bestaande installasie?<\/td><td>PCS-model, EPC-studie en beskermingsingenieur<\/td><\/tr><tr><td>Meet-, kommunikasie- en beheersdiagram<\/td><td>Watter CT's, meters en seine sluit die lus, en wat gebeur wanneer een faal?<\/td><td>EPC, EMS-integrator en <strong><a href=\"https:\/\/www.solidess.com\/af\/bess-scada-puntelys-wat-jou-ems-moet-stuur\/\" target=\"_blank\" style=\"color:#61ce70\">BESS SCADA-puntlys<\/a><\/strong><\/td><\/tr><tr><td>Kommisseringstoetskaart<\/td><td>Watter webwerftoetse bewys die aannames wat in die indiening gebruik is?<\/td><td>Eienaar, EPC en toerustingverskaffer<\/td><\/tr><\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6e470d37 auto-p elementor-widget elementor-widget-heading\" data-id=\"6e470d37\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Die 2026-ooreenkoms vereis minimum-, medium- en maksimum-aanvraag-basisscenario's. Die oorgangsbepalings sluit kragvloei, kortsluiting, bergingskrag, ontladingsduur en helling in by die moontlike ontledings van 'n Aanwysingsstudie. 'n Impakstudie kan die werk uitbrei na kortsluitingsverhouding en transi\u00ebntstabiliteit, insluitend implementering van roostervorming. Die Installasiestudie handel oor die gevolglike beskermings-, kommunikasie-, beheer- en meetvereistes.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1508eb88 auto-p elementor-widget elementor-widget-heading\" data-id=\"1508eb88\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">CENACE besluit of 'n addisionele studie van toepassing is of in aanmerking kom vir vrystelling. Selfs 'n projek wat 'n ligter roete verwag, moet die lasgevalle, toerustingsmodel en beheergedrag indien wat nodig is om daardie besluit te ondersteun.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2c87e64a auto-h2 elementor-widget elementor-widget-heading\" data-id=\"2c87e64a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Gebruik Quick Impact slegs nadat CENACE die roete toegeken het.<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-aaebbf69 auto-p elementor-widget elementor-widget-heading\" data-id=\"aaebbf69\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Die <a href=\"https:\/\/siasic.apps.cloud.cenace.gob.mx\/Home\/InfoSIASIC\" target=\"_blank\" rel=\"noopener\">CENACE SIASIC inligtingsbladsy<\/a> ly Quick Impact onder sy studietipes. Kwalifikasie hang steeds af van CENACE se klassifikasie van die spesifieke versoek.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-333729a2 auto-p elementor-widget elementor-widget-heading\" data-id=\"333729a2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Om die roete te vroeg te roep, kan daar 'n volledige kaste op bestelling geplaas word voordat CENACE die voorgestelde kW aanvaar het. 'n Ander fout voeg battery kWh by terwyl die PCS-model, reaktiewe-kragvermo\u00eb, helling en beskermingsdata onopgelos bly. CENACE bestudeer netwerkgedrag, dus s\u00ea battery kWh op sigself min oor die impak op die aansluitpunt.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-bddf853a auto-p elementor-widget elementor-widget-heading\" data-id=\"bddf853a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Die studienaam moet voorlopig bly totdat die verteenwoordiger die kennisgewing van tegniese wysiging ingedien en instruksies ontvang het. Op daardie stadium kan die skedule 'n vereiste dokument, betaling en reaksietydperk aan die korrekte roete koppel. Vanaf September 2026, die federale <a href=\"https:\/\/ventanilla.energia.gob.mx\/detalle_tramite\/MzA=\" target=\"_blank\" rel=\"noopener\">Ventanilla Energ\u00eda-bladsy vir SAE-CC<\/a> toon steeds vereistes, reaksietyd en koste as \u201cPOR DEFINIR.\u201d Inskrywingspanne moet SIASIC en die verantwoordelike owerheid op die werklike indieningsdatum nagaan. 'n Ou vormpak kan nie as 'n huidige indieningsgarantie dien nie.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ec144036 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"ec144036\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Beskik 500 kVA na Projek kW voor produkvrystelling<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9102c6ed auto-p elementor-widget elementor-widget-heading\" data-id=\"9102c6ed\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">MegSolid se <strong><a href=\"https:\/\/www.solidess.com\/af\/product\/buitekas-energiebergingstelsel\/\" target=\"_blank\" style=\"color:#61ce70\">ESSA0100B-0215 buite-kas<\/a><\/strong> Het 'n gepubliseerde 100 kW \/ 215,04 kWh beoordeling by 400 V. Vyf eenhede gee 'n eenvoudige voorlopige 500 kW \/ 1 075,2 kWh naamplaat-kombinasie. Die openbare bladsy identifiseer intelligente lugafkoeling, IP54-beskerming en 'n maksimum laai-\/ontlaaikoers van 0,5 C by 25 \u00b0C vir daardie model.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-54d84d17 auto-p elementor-widget elementor-widget-heading\" data-id=\"54d84d17\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Die <strong><a href=\"https:\/\/www.solidess.com\/af\/product\/megasoliede-soliede-vloeibare-energieberging\/\" target=\"_blank\" style=\"color:#61ce70\">Energon 261.24 vloeistofgekoelde kas<\/a><\/strong> word gepubliseer as 125 kVA \/ 261,24 kWh, met 'n 400 V- of 480 V-koppelvlak en 'n verstelbare kragfaktor. Vier eenhede beloop in totaal 500 kVA, nie outomaties 500 kW nie. By 'n bedryfs-kragfaktor van 0,90 sou die aktiewe-kraggrens wees:<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-07f6c1bb auto-p elementor-widget elementor-widget-heading\" data-id=\"07f6c1bb\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\"><strong>Aktiewe krag = 500 kVA \u00d7 0,90 = 450 kW<\/strong><\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-204dcf8f auto-p elementor-widget elementor-widget-heading\" data-id=\"204dcf8f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Die finale model moet die gewaarborgde aktiewe kragvermo\u00eb by die projekspanning, temperatuur, hoogte en kragfaktor gebruik. Energon se openbare 90%-syfer is aangewys as maksimum stelseldoeltreffendheid; dit behoort nie hernoem te word na rondritdoeltreffendheid sonder 'n beheerde toetsdefinisie nie.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7eeef3a9 auto-p elementor-widget elementor-widget-heading\" data-id=\"7eeef3a9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Vir die CENACE-l\u00eaer noem 'n bruikbare produkinsending die PCS en gee sy kW, kVA, kragfaktorbereik en ramplimiete aan. Dit identifiseer ook die beheerinterface, alarmtoestande en firmware-revisie wat by die fabriek sal aankom. Koelargitektuur en kasenergie bly belangrik vir terreinontwerp; die netwerkmodel benodig steeds die PCS-data.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-89f9dd95 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"89f9dd95\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Nul-uitvoer benodig 'n foutmodus in die model<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b22a8d06 auto-p elementor-widget elementor-widget-heading\" data-id=\"b22a8d06\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">'n Nul-uitvoerverklaring beskryf die vereiste uitkoms. Die tegniese l\u00eaer moet ook beskryf hoe die beheerapparaat dit bereik en wat die plant doen wanneer 'n sein verdwyn.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-bfe3f83b auto-p elementor-widget elementor-widget-heading\" data-id=\"bfe3f83b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Neem die PCC-meter, CT-verhouding en polariteit, monsternemingsnelheid, kommunikasieroete, invoerdoelwit, uitvoerdrempel, doodband, PCS-helling en ou-datatimer op. Die goedgekeurde skema kan die BESS na nul afbult, 'n beperkte invoer-geori\u00ebnteerde uitset handhaaf of die betrokke sekering laat afskakel. Voer die gekose aksie in beide die instellingsblad en die SAT-prosedure in.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b3d2b195 auto-p elementor-widget elementor-widget-heading\" data-id=\"b3d2b195\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Die hersiene enkellijnskets moet elke parallelle bron aandui. Bestaande PV of 'n generator verander die stroom wat by die PCC gemeet word en kan die verwagte reaksie van die bergingsbeheerder verander. Generatorbedryf benodig ook 'n gedefinieerde <strong><a href=\"https:\/\/www.solidess.com\/af\/bess-en-dieselopwekkerbeheer-sonder-omgekeerde-kraguitbrake\/\" target=\"_blank\" style=\"color:#61ce70\">BESS en dieselgenerator-beheersequentie<\/a><\/strong> indien eiland- of standby-modusse deel uitmaak van die projek.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c025e064 auto-p elementor-widget elementor-widget-heading\" data-id=\"c025e064\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Die nul-uitvoer-toets behoort \u201cn lasdaling, \u201dn meter-kommunikasie-onderbreking en -herstel vas te l\u00ea. 'n Skermkiekie wat by konstante las \"0 kW uitvoer\" wys, kan nie die dinamiese geval bewys wat gewoonlik die oortreding veroorsaak nie.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-92a852d8 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"92a852d8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Beweeg studie-aannames na SAT-rekords<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5622d5dd auto-p elementor-widget elementor-widget-heading\" data-id=\"5622d5dd\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Plaaslike toetse moet die invoer by die aansluitpunt tydens maksimum laai en die minimum invoer n\u00e1 'n vinnige laai-afname aanteken. Dieselfde neiging behoort die PCS-reaksietyd, aktiewe en reaktiewe krag, beskermingswerking en die foutveilige toestand n\u00e1 kommunikasieverlies te toon.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9f750cd4 auto-p elementor-widget elementor-widget-heading\" data-id=\"9f750cd4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Die fabriekstoets kontroleer die vervaardigde konfigurasie, serienommers, firmware, alarems en ooreengekome beheerfunksies. 'n projekspesifieke <strong><a href=\"https:\/\/www.solidess.com\/af\/bess-factory-acceptance-test-guide\/\" target=\"_blank\" style=\"color:#61ce70\">BESS-fabrieksaanvaardingstoets<\/a><\/strong> Kan ook voor versending die registerkaarte en bevelsgrense bevestig. Die terreintoetsing gebruik dan die ge\u00efnstalleerde CT's, meter, skakelaar, transformator en die werklike netwerkgrens.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4be8781f auto-p elementor-widget elementor-widget-heading\" data-id=\"4be8781f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Kopieer die aanvaarde perke vanaf die CENACE-insending of die rekord van tegniese wysiging na die EMS-instellingsblad. SAT neem dan dieselfde perke op die ondertekende tendens- en uitslaettafel op.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4626d1e0 auto-p elementor-widget elementor-widget-heading\" data-id=\"4626d1e0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">As die indiening s\u00ea dat die laai by 500 kW stop, maar die EMS 600 kW toelaat, het die fabriek die bedryfsomvang verander. As die studie nul uitvoer aanneem, maar die kommunikasieverlies-toestand die laaste ontladingsopdrag vries, bly die foutmodus oop. Dit is inbedryfstellingsgebreke, nie woordingkwessies nie.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-83dc22ca auto-h2 elementor-widget elementor-widget-heading\" data-id=\"83dc22ca\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Wat hou die finale aankoopvrystelling in<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b2e0a895 auto-p elementor-widget elementor-widget-heading\" data-id=\"b2e0a895\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Die aankoopskedule kan vroeg 'n voorlopige kabinetfamilie noem. Die finale vrystelling wag vir vyf kontroles:<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9609ab67 elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"9609ab67\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">CENACE het die roete bevestig;<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">die kontrakladingsgrens stem ooreen met die aanvraagdata;<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">die bevel noem die kabinet, PCS en beheerde hersiening;<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">die SLD bepaal die aansluitpunt;<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Die EMS-instellings en SAT-prosedure dra die veldbedryfsgrense oor.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-94dc6702 auto-p elementor-widget elementor-widget-heading\" data-id=\"94dc6702\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Die toerustingverskaffer moet die modelspesifieke beoordelingsblad, koppelvlakke, beheersdata en die ooreengekome fabriekbewyse lewer. Die plaaslike EPC besit die opname van die bestaande aanleg, die hersiene SLD, kabel- en beskermingsontwerp, CT-installasie en terreintoetse. Die verteenwoordiger van die lassentrum hanteer die CENACE-kennisgewing en -inhandiging. Die eienaar beheer die bedryfsdata en aanvaar enige produksiebeperking wat gebruik word om laadbeperkings onder die gekontrakteerde las te hou.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-51557d36 auto-p elementor-widget elementor-widget-heading\" data-id=\"51557d36\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Moenie die model sluit wanneer die laaiskedule in enige aanvraaggeval die gekontrakteerde vraglimiet oorskry nie. Om batteryeenergie by te voeg, sal die oorskryding nie regstel nie. Die eienaar moet eers die laaivenster, die PCS-opdrag of die produksieskedule verander.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b8866924 auto-p elementor-widget elementor-widget-heading\" data-id=\"b8866924\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\"><strong>Kaart die CENACE-tegniese wysigingsl\u00eaer<\/strong><\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d6cf1305 auto-p elementor-widget elementor-widget-heading\" data-id=\"d6cf1305\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Stuur die bestaande en voorgestelde SLD, gekontrakteerde las, intervalvraag, BESS-gradering, bedryfsmodusse, PCS-model en beplande inbedryfstellingsdatum. Die dokumentkaart skei die MegSolid-data, EPC-studies, eienaarsrekords en CENACE-roetebesluite wat benodig word voordat die finale toerusting vrygestel word.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-cdf767b5 elementor-tablet-align-center elementor-align-center auto-cta elementor-widget elementor-widget-button\" data-id=\"cdf767b5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"#elementor-action%3Aaction%3Dpopup%3Aopen%26settings%3DeyJpZCI6Ijk0OCIsInRvZ2dsZSI6ZmFsc2V9\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Kaart die Mexico CENACE-l\u00eaer<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-79b6d78f auto-faq e-flex e-con-boxed e-con e-child\" data-id=\"79b6d78f\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-5a4ab36d elementor-widget elementor-widget-heading\" data-id=\"5a4ab36d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">VGV<\/h2>\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-95e7d545 e-con-full e-flex e-con e-child\" data-id=\"95e7d545\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-fc27d778 elementor-widget elementor-widget-n-accordion\" data-id=\"fc27d778\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;default_state&quot;:&quot;all_collapsed&quot;,&quot;max_items_expended&quot;:&quot;one&quot;,&quot;n_accordion_animation_duration&quot;:{&quot;unit&quot;:&quot;ms&quot;,&quot;size&quot;:400,&quot;sizes&quot;:[]}}\" data-widget_type=\"nested-accordion.default\">\n\t\t\t\t\t\t\t<div class=\"e-n-accordion\" aria-label=\"Blokkiemusiekspelers. Maak skakels oop met Enter of Spasie, maak toe met Escape, en navigeer met Pyltjiesleutels\">\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-4230\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"1\" tabindex=\"0\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-4230\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> 1. Benodig 'n bestaande fabriek in Mexiko outomaties 'n CENACE-snellimpakstudie vir BESS? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-4230\" class=\"elementor-element elementor-element-eaaafc65 e-con-full e-flex e-con e-child\" data-id=\"eaaafc65\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-4230\" class=\"elementor-element elementor-element-444a5091 e-con-full e-flex e-con e-child\" data-id=\"444a5091\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-484f625f elementor-widget elementor-widget-heading\" data-id=\"484f625f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Nee. Die April 2026-ooreenkoms begin 'n bestaande lasentrum op die tegniese wysigingsroete, waarna CENACE besluit of bykomende studies van toepassing is. Die uitdruklike Estudio R\u00e1pido-bepaling dek gegroepeerde bestaande lasentrums, nie elke individuele fabriek nie.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-4231\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"2\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-4231\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> 2. Wat beteken SAEE-CC? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-4231\" class=\"elementor-element elementor-element-f26ad1c2 e-con-full e-flex e-con e-child\" data-id=\"f26ad1c2\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-4231\" class=\"elementor-element elementor-element-4c60b163 e-con-full e-flex e-con e-child\" data-id=\"4c60b163\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-42b9dbdf elementor-widget elementor-widget-heading\" data-id=\"42b9dbdf\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">SAEE-CC beteken 'n elektriese energie-opbergstelsel wat met 'n lasentrum geassosieer word en dieselfde aansluitpunt deel. Die 2026-ooreenkoms gebruik hierdie term, alhoewel sommige portaalskerms nog steeds SAE-CC wys. Volg die huidige vormetiket en behou SAEE-CC in die regs- en tegniese rekord.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-4232\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"3\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-4232\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> 3. Het 'n SAEE-CC 'n aparte bergingspermit nodig? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-4232\" class=\"elementor-element elementor-element-589efef3 e-con-full e-flex e-con e-child\" data-id=\"589efef3\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-4232\" class=\"elementor-element elementor-element-dc0a3503 e-con-full e-flex e-con e-child\" data-id=\"dc0a3503\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-0bc50089 elementor-widget elementor-widget-heading\" data-id=\"0bc50089\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Artikel 4.1 beskou die berging as deel van die lasentrum se installasies en toerusting, sodat SAEE-CC nie 'n afsonderlike energiebesparingspermit benodig nie. Daardie bepaling kanselleer nie die projek se aansluitings-, konstruksie- of plaaslike elektriese verpligtinge nie.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-4233\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"4\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-4233\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> 4. Kan 'n BESS-aanleg in 'n fabriek in Mexiko energie na die netwerk uitvoer? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-4233\" class=\"elementor-element elementor-element-9ffa09c6 e-con-full e-flex e-con e-child\" data-id=\"9ffa09c6\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-4233\" class=\"elementor-element elementor-element-317d4213 e-con-full e-flex e-con e-child\" data-id=\"317d4213\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ecb8ab70 elementor-widget elementor-widget-heading\" data-id=\"ecb8ab70\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">SAEE-CC-energie bedien die las op die perseel; inspuiting by die aansluitpunt is verbode. Die EMS sny daarom die ontlading uit lewendige PCC-metings en skakel oor na die goedgekeurde fal-veilig-toestand indien die meter sein verdwyn.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-4234\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"5\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-4234\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> 5. Kan die BESS-laai vir 'n kort tydperk die fabriek se gekontrakteerde las oorskry? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-4234\" class=\"elementor-element elementor-element-770df07f e-con-full e-flex e-con e-child\" data-id=\"770df07f\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-4234\" class=\"elementor-element elementor-element-8b0ba305 e-con-full e-flex e-con e-child\" data-id=\"8b0ba305\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-d6edfc1d elementor-widget elementor-widget-heading\" data-id=\"d6edfc1d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Nee. Gelyktydige fabrieksvraag tel by die kontrakteerladinglimiet. 'n 500 kW-laaibedrag moet val terwyl produksie- of bylas die beskikbare invoermargin verbruik.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-4235\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"6\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-4235\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> 6. Watter aanvraaggevalle behoort in die CENACE-l\u00eaer te wees? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-4235\" class=\"elementor-element elementor-element-c2d6e682 e-con-full e-flex e-con e-child\" data-id=\"c2d6e682\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-4235\" class=\"elementor-element elementor-element-b1f9efa2 e-con-full e-flex e-con e-child\" data-id=\"b1f9efa2\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-aae28a95 elementor-widget elementor-widget-heading\" data-id=\"aae28a95\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Gebruik minimum-, medium- en maksimum-vraagbasisgevalle. Koppel elke geval aan intervaldata en die voorgestelde tariefure sodat CENACE die werklike aansluitingspunt-effek kan sien.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-4236\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"7\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-4236\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> 7. Is die battery-kWh genoeg vir die CENACE-model? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-4236\" class=\"elementor-element elementor-element-b36561d3 e-con-full e-flex e-con e-child\" data-id=\"b36561d3\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-4236\" class=\"elementor-element elementor-element-6b53a372 e-con-full e-flex e-con e-child\" data-id=\"6b53a372\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-1064784d elementor-widget elementor-widget-heading\" data-id=\"1064784d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">kWh dek duur. Die CENACE-model benodig ook kW, kVA, spanning, kragfaktorbereik, laai- en ontlaaiprofiele, helling, kortsluitgedrag, beskermings- en beheergegewens.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-4237\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"8\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-4237\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> 8. Waarom moet die l\u00eaer beide kW en kVA aandui? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-4237\" class=\"elementor-element elementor-element-0d744840 e-con-full e-flex e-con e-child\" data-id=\"0d744840\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-4237\" class=\"elementor-element elementor-element-361d0b8d e-con-full e-flex e-con e-child\" data-id=\"361d0b8d\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-d8c2bdb0 elementor-widget elementor-widget-heading\" data-id=\"d8c2bdb0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">kW dui aktiewe krag aan. kVA, spanning en kragfaktor bepaal die grens vir wisselstroomstroom en reaktiewe krag. By 'n kragfaktor van 0,90 bereik 'n 125 kVA PCS 112,5 kW wanneer dit by die volle limiet van die skynbare krag werk.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-4238\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"9\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-4238\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> 9. Verwyder nuluitvoer die behoefte aan 'n hersiene SLD? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-4238\" class=\"elementor-element elementor-element-02adb411 e-con-full e-flex e-con e-child\" data-id=\"02adb411\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-4238\" class=\"elementor-element elementor-element-0ec565eb e-con-full e-flex e-con e-child\" data-id=\"0ec565eb\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a09fd900 elementor-widget elementor-widget-heading\" data-id=\"a09fd900\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Nee. Nul-eksport is 'n beheermodus, terwyl die BESS steeds die fabrieksinstallasie verander. Die hersiene SLD moet sy toevoer, aansluitpunt, transformator, ander bronne, CT's, meter, beskerming en afskakelpad aandui.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-4239\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"10\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-4239\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> 10. Wat gebeur as die Ventanilla Energ\u00eda-bladsy steeds s\u00ea dat die vereistes onbepaald is? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-4239\" class=\"elementor-element elementor-element-1469beaa e-con-full e-flex e-con e-child\" data-id=\"1469beaa\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-4239\" class=\"elementor-element elementor-element-1c73640f e-con-full e-flex e-con e-child\" data-id=\"1c73640f\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-917894bc elementor-widget elementor-widget-heading\" data-id=\"917894bc\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Bevestig die huidige SIASIC-roete by die verantwoordelike CENACE-kanaal voordat die indieningskalender vasgestel word. Vanaf September 2026 merk die SAE-CC-bladsy steeds verskeie administratiewe velde as \u201cPOR DEFINIR\u201d; 'n vroe\u00ebre kontrolelys kan nie die huidige indieningspakket waarborg nie.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-42310\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"11\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-42310\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> 11. Kan vyf 100 kW-kaste as 'n 500 kW BESS verklaar word? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-42310\" class=\"elementor-element elementor-element-c96174cb e-con-full e-flex e-con e-child\" data-id=\"c96174cb\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-42310\" class=\"elementor-element elementor-element-783f1abd e-con-full e-flex e-con e-child\" data-id=\"783f1abd\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-30e4a462 elementor-widget elementor-widget-heading\" data-id=\"30e4a462\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Vyf ESSA0100B-0215-kaste het 'n totale 500 kW op die gepubliseerde naamplaat. Die finale verklaring hang steeds af van die gelewerde PCS-konfigurasie, gelyktydige bedryfsbeperkings, bykomstighede, kragfaktor, temperatuur, hoogte en goedgekeurde behearakitektuur.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-42311\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"12\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-42311\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> 12. Watter toetse moet die CENACE-bedryfsveronderstellings herhaal? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-42311\" class=\"elementor-element elementor-element-0121e4e1 e-con-full e-flex e-con e-child\" data-id=\"0121e4e1\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-42311\" class=\"elementor-element elementor-element-ec8c74cd e-con-full e-flex e-con e-child\" data-id=\"ec8c74cd\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-810aa0d9 elementor-widget elementor-widget-heading\" data-id=\"810aa0d9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">SAT moet die ingediende bedryfsgrense herhaal: maksimum laaistroom, vinnige lasafname, nul-uitvoersrespons, meetkommunikasieversaking, aktiewe en reaktiewe krag, beskermingswerking en herstel. Die ondertekende neiging moet ooreenstem met die finale EMS-instellings.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-42312\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"13\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-42312\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> 13. Wat moet gereed wees voordat die BESS-aankoopbestelling uitgereik word? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-42312\" class=\"elementor-element elementor-element-1029717c e-con-full e-flex e-con e-child\" data-id=\"1029717c\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-42312\" class=\"elementor-element elementor-element-667dd34e e-con-full e-flex e-con e-child\" data-id=\"667dd34e\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a6cc7b26 elementor-widget elementor-widget-heading\" data-id=\"a6cc7b26\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Vry die bestelling nadat die l\u00eaer die voorlopige CENACE-roete, die kontrakladingrekord, die aanvraaggevalle, die hersiene SLD, die produk- en PCS-skedule, die bedryfsgrense, die nul-uitvoermetode en die oorsig van die aanvaardingstoets bevat. Gee elke oop aanname 'n eienaar en 'n sluitingsdatum.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>'n Aangif- en ingenieursgids vir 'n bestaande fabriek in Mexiko wat batterystoor by sy lasentrum voeg, vanaf CENACE-roete-klassifikasie tot die bedryfsomvang, studie-model en terrein-aanvaardingrekord.<\/p>","protected":false},"author":4,"featured_media":5170,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"_joinchat":[],"footnotes":""},"categories":[27,1],"tags":[535,260,531,530,532,534,533,493],"class_list":["post-5173","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-news","category-bess","tag-bess-connection-study","tag-ci-battery-storage","tag-cenace","tag-mexico-bess","tag-saee-cc","tag-siasic","tag-technical-modification","tag-zero-export"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.solidess.com\/af\/wp-json\/wp\/v2\/posts\/5173","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.solidess.com\/af\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.solidess.com\/af\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.solidess.com\/af\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/www.solidess.com\/af\/wp-json\/wp\/v2\/comments?post=5173"}],"version-history":[{"count":1,"href":"https:\/\/www.solidess.com\/af\/wp-json\/wp\/v2\/posts\/5173\/revisions"}],"predecessor-version":[{"id":5176,"href":"https:\/\/www.solidess.com\/af\/wp-json\/wp\/v2\/posts\/5173\/revisions\/5176"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.solidess.com\/af\/wp-json\/wp\/v2\/media\/5170"}],"wp:attachment":[{"href":"https:\/\/www.solidess.com\/af\/wp-json\/wp\/v2\/media?parent=5173"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.solidess.com\/af\/wp-json\/wp\/v2\/categories?post=5173"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.solidess.com\/af\/wp-json\/wp\/v2\/tags?post=5173"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}