{"id":5289,"date":"2026-09-09T09:30:51","date_gmt":"2026-09-09T01:30:51","guid":{"rendered":"https:\/\/www.solidess.com\/?p=5289"},"modified":"2026-09-09T09:30:51","modified_gmt":"2026-09-09T01:30:51","slug":"kommersiele-sonkragbatteryberging-in-die-vk","status":"publish","type":"post","link":"https:\/\/www.solidess.com\/af\/commercial-solar-battery-storage-uk\/","title":{"rendered":"Kommersi\u00eble sonkragbatterystoor in die VK: grootte volgens DNO-limiete, sonkragoverschot en halfuurlikse vraag"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"5289\" class=\"elementor elementor-5289\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-bf4793c e-con-full auto-article-root e-flex e-con e-parent\" data-id=\"bf4793c\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-84f7319d auto-image elementor-widget elementor-widget-image\" data-id=\"84f7319d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"1254\" height=\"1254\" src=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Commercial-Solar-Battery-Storage-UK-Sizing-at-an-Industrial-Site.jpg\" class=\"attachment-1536x1536 size-1536x1536 wp-image-5286\" alt=\"MegSolid kommersi\u00eble sonkragbatterystoor agter die meter by &#039;n fabriek in die VK met dak-PV, DNO-beperkings en halfuurlikse aanvraagdata\" srcset=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Commercial-Solar-Battery-Storage-UK-Sizing-at-an-Industrial-Site.jpg 1254w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Commercial-Solar-Battery-Storage-UK-Sizing-at-an-Industrial-Site-300x300.jpg 300w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Commercial-Solar-Battery-Storage-UK-Sizing-at-an-Industrial-Site-1024x1024.jpg 1024w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Commercial-Solar-Battery-Storage-UK-Sizing-at-an-Industrial-Site-150x150.jpg 150w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Commercial-Solar-Battery-Storage-UK-Sizing-at-an-Industrial-Site-768x768.jpg 768w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Commercial-Solar-Battery-Storage-UK-Sizing-at-an-Industrial-Site-12x12.jpg 12w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Commercial-Solar-Battery-Storage-UK-Sizing-at-an-Industrial-Site-600x600.jpg 600w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Commercial-Solar-Battery-Storage-UK-Sizing-at-an-Industrial-Site-100x100.jpg 100w\" sizes=\"(max-width: 1254px) 100vw, 1254px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9ef09784 auto-p elementor-widget elementor-widget-heading\" data-id=\"9ef09784\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Moenie die grootte van kommersi\u00eble sonbatterystoor in die VK bepaal deur dak-PV kWp met 'n vaste batteryratio te vermenigvuldig nie. Begin by die netwerkgrens, die sonenergie wat oor is nadat die gebou dit gebruik het, en die halfuurse aanvraagvenster wat die battery moet dek.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-913affce auto-p elementor-widget elementor-widget-heading\" data-id=\"913affce\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Drie rekords beheer die eerste groottebepalingspas:<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5707929b elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"5707929b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>DNO-grens:<\/strong> Toegelate invoer en uitvoer by die aansluitingspunt<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>Son-oorskot:<\/strong> die elektrisiteit wat oorbly nadat die gebou sy dagtydse PV-opwekking gebruik het<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>Halfuurse vraag:<\/strong> die herhaalde piek- of aandtydperk wat die battery moet dek<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-68714463 auto-p elementor-widget elementor-widget-heading\" data-id=\"68714463\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Groot dakke het nie outomaties groot batterye nodig nie. Die kasgrootte volg die gemeet gaping tussen daardie drie rekords, nie 'n kWh-per-kWp-afkorting nie.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-629d9b4e auto-h2 elementor-widget elementor-widget-heading\" data-id=\"629d9b4e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Batterygrootte kom van drie afsonderlike terreinrekords<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0b1a710b auto-p elementor-widget elementor-widget-heading\" data-id=\"0b1a710b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Verenigde Koninkryk kommersi\u00eble sonkragstoor het twee groottebepalende take. Die kragomvormer moet genoeg krag verskuif wanneer die gebeurtenis plaasvind, terwyl die battery genoeg energie moet berg om daardie gebeurtenis vir die vereiste tydperk te onderhou.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-301a98c5 auto-table elementor-widget elementor-widget-text-editor\" data-id=\"301a98c5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"cea-table-wrap\"><table><thead><tr><th>Perseelsrekord<\/th><th>Wat dit stel<\/th><th>Wat dit voorkom<\/th><\/tr><\/thead><tbody><tr><td>DNO-verbindingsooreenkoms en goedgekeurde perke<\/td><td>Maximum invoer en uitvoer by die aansluitpunt<\/td><td>'n PCS-konfigurasie wat nie onder die ooreengekome verbinding kan funksioneer nie<\/td><\/tr><tr><td>PV-opwekking en terreinlasdata wat op dieselfde interval aangeteken is<\/td><td>Faktureerbare son-oorskot in kWh<\/td><td>Koop kapasiteit wat die dak selde benut<\/td><\/tr><tr><td>Twaalf maande van halfuur-vraag<\/td><td>Benodigde aflaaivermo\u00eb in kW en die duur van elke gebeurtenis<\/td><td>'n battery wat halverwege die teikenperiode opraak<\/td><\/tr><\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-acb57b23 auto-p elementor-widget elementor-widget-heading\" data-id=\"acb57b23\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Die roostergrens, die betaalde son-oorskot en die teiken-halfuur-vraagvenster moet almal ooreenstem. Stelsels wat slegs een of twee van daardie kontroles slaag, is nie gereed vir toerustingkeuse nie.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b71d0753 auto-p elementor-widget elementor-widget-heading\" data-id=\"b71d0753\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Bestaande PV kan op sy huidige omvormer bly terwyl 'n aparte <strong><a href=\"https:\/\/www.solidess.com\/af\/product\/megsolid-kragomskakelingstelsel\/\" target=\"_blank\" style=\"color:#61ce70\">MEGA TS PCS<\/a><\/strong> gee die battery sy eie AC-gekoppelde pad, onderhewig aan skakelbord-, transformator-, beskermings- en DNO-kontroles.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b4c23425 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"b4c23425\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">PCS-krag begin by die DNO-grens.<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1b38664c auto-p elementor-widget elementor-widget-heading\" data-id=\"1b38664c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Die DNO sien die wisselstroomkrag wat die aansluitpunt kan oorsteek, nie die batterystel se energielabel nie. Dieselfde 500 kWh-batterystel vertoon 'n ander netwerkgeval agter 'n 100 kW-PCS as agter 'n 250 kW-PCS. Bestaande PV-opwekking tel ook wanneer die DNO die geaggregeerde opstelling beoordeel.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-997d92dc auto-h3 elementor-widget elementor-widget-heading\" data-id=\"997d92dc\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Skei die verbindingskapasiteit van die beheerstellingspunt<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0eb530c5 auto-p elementor-widget elementor-widget-heading\" data-id=\"0eb530c5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">VK-verbindingsdokumente kan 'n maksimum invoerkapasiteit en 'n maksimum uitvoerkapasiteit aandui. Dit is terreingrense, nie batterybevele nie. Die kli\u00ebnt se beperkingskema gebruik dan 'n maksimum invoerlimiet, 'n maksimum uitvoerlimiet of gelykwaardige goedgekeurde instellings om die gemete krag binne die ooreengekome grens te hou.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d7936b6c auto-p elementor-widget elementor-widget-heading\" data-id=\"d7936b6c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Laai maak daardie onderskeid duidelik. Die battery is 'n elektriese las terwyl dit gelaai word, so 'n EMS wat slegs op uitvoer fokus, kan toelaat dat die gekombineerde fabriekslas en battery die toegelaat ingevoerde krag oorskry. Tydens ontlading kan dieselfde terrein sy uitvoerlimiet oorskry as die fabrieksvraag skielik daal of die dakopbrengs styg.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-009b5dc3 auto-p elementor-widget elementor-widget-heading\" data-id=\"009b5dc3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Die beheerpunt sit by die terreingrens. Sy meter en CT's moet die netwerkinvoer, netwerkuitvoer, PV, batteryaksies en veranderinge in die fabriekslas waarneem. Die <strong><a href=\"https:\/\/www.solidess.com\/af\/hoe-om-bess-nul-uitvoerbeheer-by-die-pcc-te-spesifiseer\/\" target=\"_blank\" style=\"color:#61ce70\">PCC geen-uitvoerkontrolemetode<\/a><\/strong> gaan dieper in daardie meetgrens, terwyl die <strong><a href=\"https:\/\/www.solidess.com\/af\/battery-peak-shaving-control-pcc\/\" target=\"_blank\" style=\"color:#61ce70\">PCC-piekversagartikels<\/a><\/strong> Dek invoerbeheer teen 'n vraagteiken.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d2c1b340 auto-h3 elementor-widget elementor-widget-heading\" data-id=\"d2c1b340\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">G98: Die mikrogenerasie-kennisgewingsgrens<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ba7e7bec auto-p elementor-widget elementor-widget-heading\" data-id=\"ba7e7bec\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">G98 dek mikrogenereringsaanlegte wie se gesamentlike nominale stroom nie meer as 16 A per fase oorskry nie. By 230 V is dit ongeveer 3,68 kW op een fase; 'n driefase-installasie pas die stroomlimiet op elke fase toe. Dit is nie die normale roete vir 'n fabriekskaalbattery nie.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-badb8050 auto-h3 elementor-widget elementor-widget-heading\" data-id=\"badb8050\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">G99: Die roete vir goedkeuring van verbindings<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e2a40f39 auto-p elementor-widget elementor-widget-heading\" data-id=\"e2a40f39\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Kommersi\u00eble PV en berging bo die G98-grens gaan gewoonlik deur G99 voordat hulle gekoppel word, in plaas daarvan om n\u00e1 installasie kennis te gee. Die DNO beoordeel die aggregategreling, insluitend bestaande PV en die beoogde battery-PCS. Die <a href=\"https:\/\/www.energynetworks.org\/assets\/images\/Resource%20library\/G99%20Types%20B-D%20Full%20Guide.pdf\" target=\"_blank\" rel=\"noopener\">Energie Netwerke Vereniging se verbindingsgids<\/a> Stel die huidige definisies en aansoekroetes uiteen.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-141c0d33 auto-p elementor-widget elementor-widget-heading\" data-id=\"141c0d33\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Die 50 kW-drempel wat deur 'n DNO aangedui word, kan 'n toepassingsdiensgrens wees in plaas van 'n nasionale G98\/G99-re\u00ebl. <a href=\"https:\/\/www.ukpowernetworks.co.uk\/low-carbon-technology-commercial\/solar-and-storage-at-my-business-whats-involved\" target=\"_blank\" rel=\"noopener\">VK Kragnetwerke<\/a>, byvoorbeeld, skei sy 5\u201350 kW geoutomatiseerde roete af van projekte van 50 kW of meer.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6790519e auto-h3 elementor-widget elementor-widget-heading\" data-id=\"6790519e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">G100: Invoer- en uitvoerbeperking<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ccbcb825 auto-p elementor-widget elementor-widget-heading\" data-id=\"ccbcb825\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">G100 stel die tegniese vereistes vir kli\u00ebnt-invoer- en uitvoerbeperkingskemas. Dit bepaal hoe die terrein die aansluitpunt meet, beheerde toestelle beperk en veilig faal wanneer 'n meter, beheerder of kommunikasieroete verlore gaan.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-72d373a2 auto-p elementor-widget elementor-widget-heading\" data-id=\"72d373a2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\"><strong>Moenie \u201cG100 reageer binne 15 sekondes\u201d as die kontrolespesifikasie skryf nie.<\/strong> G100 Uitgawe 2 wysiging 2 behandel kort uitstappies, die terugkeers-tot-limietperiode en faalveilige tydsberekening as afsonderlike vereistes; die aanvaarde projekinstellings moet steeds gedefinieer en getoets word.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6aad7454 auto-table elementor-widget elementor-widget-text-editor\" data-id=\"6aad7454\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"cea-table-wrap\"><table><thead><tr><th>Re\u00ebl of grens<\/th><th>Wat dit regeer<\/th><th>Wie moet dit deur die VK-projek voer<\/th><\/tr><\/thead><tbody><tr><td>G98<\/td><td>Kennisgewingsroete vir gekwalifiseerde mikrogenerering<\/td><td>Installateur en toepaslike DNO<\/td><\/tr><tr><td>G99<\/td><td>Aansluiting van opwekking en berging bo die G98-roete<\/td><td>Aansoeker \/ VK-elektriese projekparty en relevante DNO<\/td><\/tr><tr><td>G100<\/td><td>Goedgekeurde invoer-\/uitvoerverminderingskema, meting, reaksie en foutveilige gedrag<\/td><td>VK-beheerders \/ elektriese projekparty, toerustingverskaffer en relevante DNO<\/td><\/tr><tr><td>Lid van die Provinsiale Wetgewende Raad \/ Provinsiale Minister<\/td><td>Kontrakteerde of ooreengekome terrein-invoer- en uitvoerkapasiteit<\/td><td>Webwerf-eienaar, verskaffer \/ netwerkpartye soos van toepassing<\/td><\/tr><tr><td>MIL \/ MEL of goedgekeurde stelpunte<\/td><td>Bedryfsgrense afgedwing deur die beheerskema<\/td><td>Plaaslike EMS \/ beperkingsbeheerder volgens die goedgekeurde ontwerp<\/td><\/tr><\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ea96d618 auto-p elementor-widget elementor-widget-heading\" data-id=\"ea96d618\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">MegSolid kan toerustingsdata, PCS-konfigurasie-inligting en beheer-koppelvlakondersteuning verskaf. Die in die VK aangestelde EPC, elektriese kontrakteur, ICP of ander verantwoordelike projekparty moet benoem word vir die G99-insending, G100-skema-integrasie, energisering\/inbedryfstelling en foutreaksie-oordrag; die betrokke DNO bly die netwerkgoedkeuringsowerheid.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f14bdc28 auto-h3 elementor-widget elementor-widget-heading\" data-id=\"f14bdc28\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Beperkte roosterkrag kan 'n langerduursame battery ondersteun.<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-317f36fa auto-p elementor-widget elementor-widget-heading\" data-id=\"317f36fa\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Invoerbeperkings beperk hoofsaaklik hoe vinnig die battery gelaai kan word; hulle bepaal nie die gestoor energie op dieselfde waarde nie. Plekke met oornag oortollige kapasiteit kan 'n 215 kWh- of 261,24 kWh-kas stadig laai, en dan daardie energie tydens 'n korter dagpiek gebruik. Die berekening moet bewys dat die beskikbare laaivenster die vereiste laadtoestand voor die volgende gebeurtenis kan herstel.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f1828879 auto-p elementor-widget elementor-widget-heading\" data-id=\"f1828879\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Die toerustingskedule moet nie gevries word totdat die DNO die voorgestelde opwekkingskapasiteit, bedryfsgrense en beheersre\u00eblings aanvaar het nie. MegSolid-kraggraderinge beskryf wat die toerusting kan doen; dit is nie bewys dat 'n bepaalde PCS of beperkingskema VK-aansluitingsgoedkeuring het nie.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-726869c0 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"726869c0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Daaglikse laaienergie kom van gemeete sonenergie-oorskot<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-35baee10 auto-p elementor-widget elementor-widget-heading\" data-id=\"35baee10\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Die beoordeling van die sonpaneelreeks beskryf die gelykstroomuitset onder toetsomstandighede, nie die energie wat werklik die battery bereik nie. Die gebou neem eers sy deel, en slegs die oorblywende krag is beskikbaar vir laai.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-47256a1d auto-p elementor-widget elementor-widget-heading\" data-id=\"47256a1d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Elke halfuurinterval gebruik:<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-37987705 auto-p elementor-widget elementor-widget-heading\" data-id=\"37987705\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\"><code>Son-oorskot_i = max(PV-opbrengs_i - terreinlas_i,0) \u00d7 0,5 h<\/code><\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3ae9c242 auto-p elementor-widget elementor-widget-heading\" data-id=\"3ae9c242\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Voeg daardie intervalle oor elke dag by, en skei dan werkdae, naweke en seisoene. Die jaarlikse opwekkings totaal kan die ure verberg wanneer die dak en die battery werklik kan ontmoet.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6dbb9e12 auto-p elementor-widget elementor-widget-heading\" data-id=\"6dbb9e12\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Die netmeter mag dalk nie albei waardes openbaar nie, omdat agter-die-meter PV reeds die geregistreerde invoer verminder het.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9f806814 auto-table elementor-widget elementor-widget-text-editor\" data-id=\"9f806814\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"cea-table-wrap\"><table><thead><tr><th>Dieselfde halfuurinterval<\/th><th>Krag<\/th><\/tr><\/thead><tbody><tr><td>Roosterinvoer gesien by die PCC<\/td><td>100 kW<\/td><\/tr><tr><td>PV op die dak wat die gebou van krag voorsien<\/td><td>50 kW<\/td><\/tr><tr><td>Eigentlike werklading van die terrein<\/td><td>150 kW<\/td><\/tr><\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8fd3bd9b auto-p elementor-widget elementor-widget-heading\" data-id=\"8fd3bd9b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">PV-inverteropnames of 'n korrek geplaasde terreinmeter is nodig om die gelyktydige las te rekonstrueer; deur 100 kW invoer as 100 kW fabrieksvraag te beskou, verberg dit 50 kW terreinverbruik.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3814fe5c auto-table elementor-widget elementor-widget-text-editor\" data-id=\"3814fe5c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"cea-table-wrap\"><table><thead><tr><th>Webwerfprofiel<\/th><th>Wat dieselfde PV-reeks vir berging kan produseer<\/th><\/tr><\/thead><tbody><tr><td>Standaardure-pakhuis<\/td><td>Min oortollige energie gedurende weeksdae as konveyers, ventilasie- en hanteertoerusting die sonenergie gebruik soos dit opgewek word.<\/td><\/tr><tr><td>Kantoor of skool<\/td><td>Meer oortollige voorraad oor naweke en vakansiedae, maar minder aanvraag op die perseel om dit later te verbruik.<\/td><\/tr><tr><td>Koue berging of twee-skof-fabriek<\/td><td>'n Meer konstante las kan sonenergie direk absorbeer; berging is nuttig waar 'n herhaalbare surplus vir die aandskof oorbly.<\/td><\/tr><tr><td>Boerdery of seisoenale verwerker<\/td><td>Oorskot kan maandeliks skerp verander, so jaarlikse gemiddeldes kan na die verkeerde kasgrootte wys.<\/td><\/tr><\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7491c7d2 auto-image elementor-widget elementor-widget-image\" data-id=\"7491c7d2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"1448\" height=\"1086\" src=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Same-UK-Commercial-Solar-Array-Different-Battery-Capacity.jpg\" class=\"attachment-1536x1536 size-1536x1536 wp-image-5287\" alt=\"Halfuurdiagramme wat wys hoe dieselfde kommersi\u00eble sonpaneelinstallasie in die VK by &#039;n pakhuis, kantoor en &#039;n fabriek met twee skofte verskillende oortollige batterylaaivermo\u00eb lewer.\" srcset=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Same-UK-Commercial-Solar-Array-Different-Battery-Capacity.jpg 1448w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Same-UK-Commercial-Solar-Array-Different-Battery-Capacity-300x225.jpg 300w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Same-UK-Commercial-Solar-Array-Different-Battery-Capacity-1024x768.jpg 1024w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Same-UK-Commercial-Solar-Array-Different-Battery-Capacity-768x576.jpg 768w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Same-UK-Commercial-Solar-Array-Different-Battery-Capacity-16x12.jpg 16w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Same-UK-Commercial-Solar-Array-Different-Battery-Capacity-600x450.jpg 600w\" sizes=\"(max-width: 1448px) 100vw, 1448px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-764c6ce2 auto-p elementor-widget elementor-widget-heading\" data-id=\"764c6ce2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Die eerste energiedoelwit is die kleiner herhaalbare hoeveelheid: oortollige dagsonenergie of die latere las wat beskikbaar is om dit te verbruik. Gedetailleerde groottebepaling moet dan voorsiening maak vir omskakelingsverliese, beskermde staat-van-laaibeperkings en die bruikbare energie wat by die vereiste lewenspunt belowe is.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-fa7d3cc3 auto-p elementor-widget elementor-widget-heading\" data-id=\"fa7d3cc3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Skermverhoudings soos 0,4\u20130,8 kWh berging per kWp sonkrag kan help om vroe\u00eb konsepte te vergelyk. Hulle kan nie 'n aankooporder uitreik nie. Die 500 kWp-dak met 60 kWh herhaalbare weeksurplus het geen gereelde gebruik vir 'n 400 kWh son-slegs laaidoelwit nie, terwyl dieselfde dak bo 'n stille naweekterrein 'n ander bedryfsplan kan regverdig.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b03a70f1 auto-p elementor-widget elementor-widget-heading\" data-id=\"b03a70f1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Die <strong><a href=\"https:\/\/www.solidess.com\/af\/pv-charging-priority-ci-bess\/\" target=\"_blank\" style=\"color:#61ce70\">PV-laaiprioriteit<\/a><\/strong> Dit behoort eers ingestel te word nadat hierdie surplus sigbaar is. Anders kan die battery van die netwerk af gelaai word voordat die sterkste sonure aanbreek, wat geen plek laat vir die elektrisiteit wat die projek beoog het om te behou nie.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-152555a5 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"152555a5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Halfuurse aanvraag skei PCS kW van battery-kWh<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b55f4841 auto-p elementor-widget elementor-widget-heading\" data-id=\"b55f4841\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Halfuursdata toon die deel van die laskurf wat die battery van die netmeter moet verwyder. Kies eers 'n invoerdoelwit, en bereken dan die gaping bo daardie doelwit in elke afrekeninterval:<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-074332bd auto-p elementor-widget elementor-widget-heading\" data-id=\"074332bd\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\"><code>Batterykrag_i=maksimum(terreinvraag_i-invoersdoelwit,0)<\/code><\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-10143ee2 auto-p elementor-widget elementor-widget-heading\" data-id=\"10143ee2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Die hoogste herhaalde gaping bepaal die begin-PCS-krag; die area onder daardie gebeurtenis bepaal die energievereiste:<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-50feabfd auto-p elementor-widget elementor-widget-heading\" data-id=\"50feabfd\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\"><code>Geleentheidsenergie=\u03a3(batterystroom_i\u00d70,5 h)<\/code><\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7f92ef8a auto-p elementor-widget elementor-widget-heading\" data-id=\"7f92ef8a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Stel jou voor 'n fabriek bereik 420 kW teenoor 'n teiken van 300 kW. Die battery moet 120 kW by die aansluitpunt voorsien. As daardie gaping vir 'n halfuur duur, verteenwoordig dit 60 kWh.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-61af8625 auto-p elementor-widget elementor-widget-heading\" data-id=\"61af8625\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">As dit vir vier halfuurintervalle aanbly, verteenwoordig dit 240 kWh. Albei gebeure vra vir dieselfde ontladingskrag; die tweede benodig vier keer soveel energie.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9a01e670 auto-p elementor-widget elementor-widget-heading\" data-id=\"9a01e670\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Daardie syfers openbaar twee slegte kortpaaie. Die 100 kW \/ 215,04 kWh-kas het genoeg naamplaatenergie vir die eerste gebeurtenis, maar kan nie die volle 120 kW-gaping op eie houtjie uitvee nie. 'n Groter battery agter dieselfde 100 kW PCS sou langer duur, maar sou steeds minstens 20 kW bo die teiken laat terwyl die piek voortduur.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9cb81e0b auto-p elementor-widget elementor-widget-heading\" data-id=\"9cb81e0b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Voer dieselfde berekening oor die hele jaar uit. Een toevallige piek mag nie meer PCS regverdig nie, terwyl 'n laer piek wat elke weeksdag voorkom, die besparings kan oorheers. Ondersoek hierdie patrone afsonderlik:<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-bf7f36e4 elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"bf7f36e4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">die hoogste gemeete invoer;<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">die piek wat dikwels genoeg herhaal om saak te maak;<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">die aantal agtereenvolgende halfure bo die gekose teiken;<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">die aand- of tariefvenster wat vir losmaking geskeduleer is;<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">die laagste las wat uitvoer kan veroorsaak terwyl die battery ontlaai.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-34cd350f auto-p elementor-widget elementor-widget-heading\" data-id=\"34cd350f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Piekvlakking beheer steeds die meting van krag by die aansluitpunt. As 'n motor binne 'n halfuurinterval begin, kan die afrekeningsopname sy faktureringsuitwerking wys, maar die subsekonde-elektriese gebeurtenis verberg. Spanningsondersteuning en motorstart vereis 'n aparte ho\u00eb-resolusie-ondersoek; dit kan nie uit die halfuur-energie-model afgelei word nie.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0c28162e auto-p elementor-widget elementor-widget-heading\" data-id=\"0c28162e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Die naamplaat-kWh is nie dieselfde as die energie wat beskikbaar is vir die teikenlas nie. Die reservelaadtoestand, bedryfsbeperkings, verouderingsveronderstellings en die kontraktuele meetgrens verminder almal die hoeveelheid wat geskeduleer kan word. Die finale vergelyking moet die gewaarborgde bruikbare energie by 'n ooreengekome grens en lewenspunt gebruik, nie slegs die nominale batterykapasiteit nie.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b7437980 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"b7437980\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">'n VK-fabrieksvoorbeeld plaas die drie rekords op een tydlyn<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9a166032 auto-p elementor-widget elementor-widget-heading\" data-id=\"9a166032\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Oorweeg 'n fabriek met 500 kWp bestaande dak-PV, 'n ooreengekome invoerkapasiteit van 450 kW en 'n uitvoerlimiet van 50 kW. Produksie loop van 06:00 tot 22:00. Die energiebestuurder wil die netwerkinvoer gedurende 'n herhalende laatmiddag-produksieperiode onder 350 kW hou. Dit is 'n handrekenaartoetsmaatstaf, nie 'n voorkeur MegSolid-projekgrootte nie: 'n 200 kW-terrein en 'n 500 kW-terrein gebruik dieselfde halfuurmetode teen hul eie PCC-teiken.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a101db1f auto-p elementor-widget elementor-widget-heading\" data-id=\"a101db1f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Twaalf maande se halfuur-opnames lewer die volgende uitskakelingsresultaat:<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c7c4a727 auto-table elementor-widget elementor-widget-text-editor\" data-id=\"c7c4a727\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"cea-table-wrap\"><table><thead><tr><th>Opname<\/th><th>Gemeten resultaat<\/th><th>Effek op die batterijbesluit<\/th><\/tr><\/thead><tbody><tr><td>Hoogste herhaalde aanvraag bo die 350 kW-teiken<\/td><td>95 kW<\/td><td>PCS moet by die PCC ten minste 95 kW lewer.<\/td><\/tr><tr><td>Energie bo die teiken oor die geselekteerde gebeurtenis<\/td><td>165 kWh<\/td><td>Geskeduleerde bruikbare energie moet na toepaslike perke en reserwe 165 kWh oorskry.<\/td><\/tr><tr><td>Mediane PV-oorskot op weeksdae van April tot September<\/td><td>210 kWh<\/td><td>Gewoonlik is genoeg sonkrag beskikbaar om die gebeurtenis te dek voordat verliese en bedryfsmarge toegepas word.<\/td><\/tr><tr><td>Mediane PV-oorskot op weeksdae van November tot Februarie<\/td><td>65 kWh<\/td><td>Sonnkrag alleen kan nie die beplande afvoer elke winterdag herstel nie.<\/td><\/tr><tr><td>Laagste webwerf-lading terwyl volle PV-uitset moontlik is<\/td><td>140 kW<\/td><td>Uitvoerkontrole moet steeds reageer as produksie onverwags daal.<\/td><\/tr><\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1300bbc5 auto-p elementor-widget elementor-widget-heading\" data-id=\"1300bbc5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Die 500 kWp-dak regverdig op sigself nie 200\u2013400 kWh berging nie. Die eerste toerustingdoelwit is ongeveer 100 kW PCS-krag en meer as 165 kWh skeduleerbare energie. Die presiese batterykapasiteit hang af van die waarborg vir bruikbare energie, die staat-van-laadreserwe, verwagte agteruitgang en of die operateur 'n kleiner winterontlading aanvaar.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-15f5bd8e auto-p elementor-widget elementor-widget-heading\" data-id=\"15f5bd8e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">ESSA0100B-0215 lewer 100 kW beoordeelde wisselstroomkrag en 215,04 kWh nominale kapasiteit, wat dit naby die gemeete vereiste bring sonder om die projek na 'n megawattuur-houer te skuif. Dit benodig steeds 'n bruikbare-energie-ondersoek: 215,04 kWh op die naamplaat bewys nie dat 165 kWh beskikbaar sal wees by die vereiste wisselstroomgrens gedurende die gekontrakteerde lewensduur nie.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d0f13848 auto-p elementor-widget elementor-widget-heading\" data-id=\"d0f13848\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Die 261,24 kWh MegSolid vloeistofgekoelde stelsel verhoog die energie-reserwe en het 'n 125 kVA-gegradeerde wisselstroomuitset. Daardie 125 kVA mag nie as 125 kW beskou word sonder die projek se kragfaktor en bedryfsgrense nie. Dit word die sterker kandidaat as die fabriek 'n langer aandvenster, 'n groter reserve of minder sensitiwiteit vir veroudering wil h\u00ea, mits die kragstudie die vereiste werklike kraguitset bevestig.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-747987fc auto-h3 elementor-widget elementor-widget-heading\" data-id=\"747987fc\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Winter verander die skedule, nie die groottebepalingsmetode nie<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6006a255 auto-p elementor-widget elementor-widget-heading\" data-id=\"6006a255\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Winter verander die bedryfsrooster, nie die groottegrondslag nie. Die fabriek kan die geskeduleerde aflewering verminder, vrye invoerkapasiteit gebruik vir beheerde buite-piek-laai, of kapasiteit slegs byvoeg wanneer die ekstra energie 'n tweede herhaalbare taak het. Die EMS moet ophou om die netwerk te laai voordat die gekombineerde vraag van die terrein die goedgekeurde invoergrens bereik.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-251848f9 auto-p elementor-widget elementor-widget-heading\" data-id=\"251848f9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">As die fabriek later 'n tweede produksielyn byvoeg, kan die oorspronklike halfuurberekening weer uitgevoer word teen die nuwe teiken. Daardie bewyse wys of nog 'n kas, meer PCS-krag of 'n skuif na die 500 kW \/ 1.0752 MWh-klas geregverdig is.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-daaa6d28 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"daaa6d28\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Produkseleksie begin nadat die terreinnommers bekend is.<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8c74d981 auto-p elementor-widget elementor-widget-heading\" data-id=\"8c74d981\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">MegSolid bied verskeie krag-na-energie-kombinasies aan. Die gemeete las, die DNO-grens en die bedryfsvenster bepaal watter klas relevant is.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-617cb146 auto-table elementor-widget elementor-widget-text-editor\" data-id=\"617cb146\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"cea-table-wrap\"><table><thead><tr><th>Webwerf-resultaat<\/th><th>MegSolid produkpad<\/th><th>Wat dit op die terrein kan doen<\/th><th>Grense om te bevestig<\/th><\/tr><\/thead><tbody><tr><td>Bestaande kommersi\u00eble PV bly in diens<\/td><td><strong><a href=\"https:\/\/www.solidess.com\/af\/product\/megsolid-kragomskakelingstelsel\/\" target=\"_blank\" style=\"color:#61ce70\">MEGA TS PCS, 30\u2013500 kW<\/a><\/strong><\/td><td>Gee die battery 'n aparte AC-gekoppelde kragpad en stel in staat dat PCS-krag onafhanklik van battery-energie gekies kan word.<\/td><td>Gekombineerde G99-kapasiteit, goedgekeurde G100-beheer, battery-DC-ooreenstemming en skakelbordgradering<\/td><\/tr><tr><td>Tot 100 kW met 'n nominale energieverhouding van ongeveer twee uur<\/td><td><strong><a href=\"https:\/\/www.solidess.com\/af\/product\/buitekas-energiebergingstelsel\/\" target=\"_blank\" style=\"color:#61ce70\">ESSA0100B-0215, 100 kW \/ 215,04 kWh<\/a><\/strong><\/td><td>Bedek herhaalde piekvlakverwydering of skuif die gemeete sonoverschuss na 'n latere bedryfsvenster.<\/td><td>Gegarandeerde bruikbare energie, seisoenale herlaai, PCC-beheer en IP54-plasing<\/td><\/tr><tr><td>'n langer energie-venster rondom die 100 kW-klas<\/td><td><strong><a href=\"https:\/\/www.solidess.com\/af\/product\/megasoliede-soliede-vloeibare-energieberging\/\" target=\"_blank\" style=\"color:#61ce70\">MegSolid 261.24 kWh vloeistofgekoelde stelsel<\/a><\/strong><\/td><td>Voeg nominale energie-reserwe by en gebruik beheerde vloeistofafkoeling; gepubliseerde stelsels kan parallel werk.<\/td><td>125 kVA werklike kragvermo\u00eb, bylas, definisie van bruikbare energie en parallelle beheer<\/td><\/tr><tr><td>Kampus of nywerheidsentrum nader aan 500 kW<\/td><td><strong><a href=\"https:\/\/www.solidess.com\/af\/product\/gekonteineerde-energiebergingsisteem\/\" target=\"_blank\" style=\"color:#61ce70\">ESSC0500B-1075, 500 kW \/ 1.0752 MWh<\/a><\/strong><\/td><td>Skuif die projek in 'n enkele gekontaineriseerde krag- en energieblok.<\/td><td>Ongeveer 6 m en 21 t toerusting, transformatorkapasiteit, 400 V-stroom, beskerming en DNO-studie<\/td><\/tr><\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ee0cef78 auto-image elementor-widget elementor-widget-image\" data-id=\"ee0cef78\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"1448\" height=\"1086\" src=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/UK-Factory-95-kW-Peak-Gap-Matched-to-a-100-kW-Battery-Cabinet.jpg\" class=\"attachment-1536x1536 size-1536x1536 wp-image-5288\" alt=\"Verenigde Koninkryk-fabrieks halfuur-aanvraaggrafiek wat &#039;n herhaalde 95 kW-gaping bo die invoerdoelwit wys, gekoppel aan &#039;n 100 kW MegSolid ESSA-kas, met 165 kWh gebeurtenisenergie wat afsonderlik getoon word\" srcset=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/UK-Factory-95-kW-Peak-Gap-Matched-to-a-100-kW-Battery-Cabinet.jpg 1448w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/UK-Factory-95-kW-Peak-Gap-Matched-to-a-100-kW-Battery-Cabinet-300x225.jpg 300w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/UK-Factory-95-kW-Peak-Gap-Matched-to-a-100-kW-Battery-Cabinet-1024x768.jpg 1024w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/UK-Factory-95-kW-Peak-Gap-Matched-to-a-100-kW-Battery-Cabinet-768x576.jpg 768w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/UK-Factory-95-kW-Peak-Gap-Matched-to-a-100-kW-Battery-Cabinet-16x12.jpg 16w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/UK-Factory-95-kW-Peak-Gap-Matched-to-a-100-kW-Battery-Cabinet-600x450.jpg 600w\" sizes=\"(max-width: 1448px) 100vw, 1448px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-238d1494 auto-p elementor-widget elementor-widget-heading\" data-id=\"238d1494\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">ESSA is die naaste ooreenkoms wanneer die terrein\u00addata op 'n 100 kW-plafon en ongeveer twee uur nominale berging dui. Energon word nuttig wanneer die kragvereiste in 'n soortgelyke klas bly, maar die ontlaaivenster, reserwe of toekomstige verouderingsvoorsiening meer energie benodig. ESSC behoort tot 'n ander elektriese en siviele skaal; dit behoort nie verskeie klein kaste te vervang net omdat die koste per nominale kWh laer blyk te wees nie.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-869ea4a3 auto-p elementor-widget elementor-widget-heading\" data-id=\"869ea4a3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">MEGA TS laat die projek toe om batteryeenergie by te voeg sonder om 'n diensbare soninverter te vervang. Daardie buigsaamheid skep ook 'n ander koppelvlak: die DNO sal die gekombineerde opwekkingsre\u00eblings beoordeel, en die terreinbeheerder moet die ou PV-inverter by die aansluitpunt met die nuwe batterye-PCS ko\u00f6rdineer.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-18bf5452 auto-p elementor-widget elementor-widget-heading\" data-id=\"18bf5452\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Produktgraderinge verleen nie G99-aanvaarding nie. Die gekose PCS-variant, tipe-toetsbewyse, beskermingsinstellings en kli\u00ebntbeperkingskema moet teen die huidige DNO-toepassing nagekyk word voordat die toerustingskedule vrygestel word.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-76db090b auto-p elementor-widget elementor-widget-heading\" data-id=\"76db090b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Wanneer die gemeete vereiste tussen 215,04 en 261,24 kWh l\u00ea, vergelyk albei konfigurasies teen dieselfde PCC-kragdoelwit en bedryfsvenster.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c8de9e48 auto-h3 elementor-widget elementor-widget-heading\" data-id=\"c8de9e48\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Stuur een grens-ooreenstemmende datapakket<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e9e4d3df auto-p elementor-widget elementor-widget-heading\" data-id=\"e9e4d3df\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">'n Nuttige eerste e-pos het nie 'n webvorm nodig nie. Heg die drie rekords aan wat die battery bepaal:<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c29403b6 elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"c29403b6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>DNO:<\/strong> goedgekeurde invoer- en uitvoer-kW, plus die huidige G99 \/ G100-posisie;<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>12 maande se halfuurlikse data:<\/strong> PCC-invoer\/uitvoer in lyn met PV-uitset oor dieselfde tydintervalle;<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>Bedryfsvenster:<\/strong> piekvlakdoelwit in kW, opeenvolgende halfure wat gedek moet word, en of beheerde buitepiek-netlaaiing toegelaat word.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0b47e379 auto-p elementor-widget elementor-widget-heading\" data-id=\"0b47e379\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Vra vir die ESSA 100 kW \/ 215,04 kWh-roete, die 125 kVA \/ 261,24 kWh vloeistofgekoelde roete en enige afsonderlike MEGA TS PCS-vereiste om teen dieselfde grens vergelyk te word. in die fabrieksvoorbeeld hierbo moet die antwoord ook wys hoe die 65 kWh-mediane wintersol\u00eare surplus die bedryfsskedule verander in plaas daarvan om dit binne 'n jaarlikse gemiddelde te verberg.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d5ac86fa elementor-tablet-align-center elementor-align-center auto-cta elementor-widget elementor-widget-button\" data-id=\"d5ac86fa\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"#elementor-action%3Aaction%3Dpopup%3Aopen%26settings%3DeyJpZCI6Ijk0OCIsInRvZ2dsZSI6ZmFsc2V9\" target=\"_blank\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Ontvang 'n voorlopige BESS-grootte en die aanbevole produkroete<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f520b9cc auto-h2 elementor-widget elementor-widget-heading\" data-id=\"f520b9cc\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">EMS Control sit agter die DNO-grens.<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1855963f auto-p elementor-widget elementor-widget-heading\" data-id=\"1855963f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Tariefoptimalisering moet binne die DNO-limiete bly. Weekdagbeheer kan hierdie volgorde volg:<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-51986683 elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"51986683\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">1. Voorsien die gebou direk van daksolpaneel-PV.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">2. Laai vanaf die gemeet son-oorskotte terwyl die invoerreserwe behou word.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">3. Handhaaf genoeg laaivlak vir die geselekteerde laatmiddaggeleentheid.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">4. Ontlading wanneer die PCC-invoer die gekose teiken naderkom.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">5. Verminder die aflewering indien dalende fabrieksvraag of stygende PV die terrein na sy uitvoerlimiet sou stoot.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ed4d212f auto-p elementor-widget elementor-widget-heading\" data-id=\"ed4d212f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Die beheerder het 'n regstreekse PCC-meting nodig omdat die batterystroom binne die kas nie wys wat die DNO sien nadat PV en fabrieksvraag gekombineer is nie.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-938214cf auto-p elementor-widget elementor-widget-heading\" data-id=\"938214cf\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\"><strong>CT-waarskuwing:<\/strong> Omgekeerde polariteit of 'n verkeerde fase-toewysing kan daartoe lei dat die EMS die invoer- of uitvoerlek wat dit veronderstel is om reg te stel, verhoog. Die <strong><a href=\"https:\/\/www.solidess.com\/af\/bess-ct-polarity-metering-commissioning\/\" target=\"_blank\" style=\"color:#61ce70\">Metering en CT-poolriglyn<\/a><\/strong> dek die inbedingskontrole.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-26873c87 auto-p elementor-widget elementor-widget-heading\" data-id=\"26873c87\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">G100-logika neem voorrang bo die gewone tariefskedule. Met slegs 35 kW invoercapaciteit moet 'n versoekte 100 kW-laai verminder word; as 'n produksielyn tydens ontlading afskakel, moet die battery-uitset daal voordat die terrein die goedgekeurde uitvoerlimiet oorskry. Verlies aan meting, beheerderkrag of kommunikasie moet die veiligheidsreaksie wat deur die DNO aanvaar is, aktiveer.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-85935de4 auto-p elementor-widget elementor-widget-heading\" data-id=\"85935de4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Die staat-van-laaiprioriteit bepaal dan hoeveel energie oor is vir die geselekteerde gebeurtenis. Die <strong><a href=\"https:\/\/www.solidess.com\/af\/bess-ems-priority-logic\/\" target=\"_blank\" style=\"color:#61ce70\">EMS-prioriteitslogika<\/a><\/strong> dek die konflik tussen PV-laai, piekvermindering en reserwe.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e1a123f3 auto-p elementor-widget elementor-widget-heading\" data-id=\"e1a123f3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Roostergekoppelde piekvermindering en rugsteun is afsonderlike bedryfsgevalle. Om fabriekslaste tydens 'n onderbreking te handhaaf, benodig 'n goedgekeurde eilandvormingsre\u00ebl, 'n gedefinieerde rugsteunbord, omskakeling en 'n PCS-bedryfsmodus wat spanning sonder die rooster kan vestig. Die onderskeid word behandel in die <strong><a href=\"https:\/\/www.solidess.com\/af\/netgekoppelde-batterypakket-waarom-bess-afskakel-by-kragonderbreking\/\" target=\"_blank\" style=\"color:#61ce70\">Gids vir grid-aangeslote battery-ondersteuning<\/a><\/strong> en mag nie by die spaarkas gevoeg word nie, tensy die elektriese ontwerp dit insluit.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6a9c5898 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"6a9c5898\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Spaargeld hang af van die faktuuritem wat die battery eintlik verander<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-073749d6 auto-p elementor-widget elementor-widget-heading\" data-id=\"073749d6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Elke afgelewerde kilowattuur het slegs waarde deur die laaibron en die rekeningspost wat dit werklik verander. Om elke gestoor eenheid as 'n vermyde piekpryisinvoer te beskou, oorskat die resultaat.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9a2e81dd auto-p elementor-widget elementor-widget-heading\" data-id=\"9a2e81dd\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Sonlaai begin met:<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-44a45fc7 auto-p elementor-widget elementor-widget-heading\" data-id=\"44a45fc7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\"><code>Bruto waarde per uitgereikte kWh = vermyde invoerprys - opgeofferde uitvoerwaarde<\/code><\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-080aa5fa auto-p elementor-widget elementor-widget-heading\" data-id=\"080aa5fa\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Omskakelingsverliese, bykomstigheidsverbruik, battery-slijtage en onderhoud moet nog afgetrek word. As 'n terrein vermy om elektrisiteit teen 28 p\/kWh te koop, maar gee 'n uitvoerbetaling van 8 p\/kWh op, is die beginverspreiding 20 p\/kWh, nie 28 p\/kWh nie. Daardie syfers illustreer die berekening; die model moet die terrein se huidige invoercontract en uitvoerooreenkoms gebruik.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-780c8615 auto-p elementor-widget elementor-widget-heading\" data-id=\"780c8615\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Roosterlaai gebruik 'n ander waardeberekening. Die waarde begin by die invoerprys vir die ontladingsperiode minus die koste van die aankoop van ekstra laaienergie gedurende die gekose lae-prysperiode. Die laaiskedule moet ook binne die toegelate invoerpas bly en genoeg speling vir die fabriek oorlaat.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7a846c60 auto-h3 elementor-widget elementor-widget-heading\" data-id=\"7a846c60\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Netwerkfooie benodig die terrein se tariefskedule.<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-62e71e1b auto-table elementor-widget elementor-widget-text-editor\" data-id=\"62e71e1b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"cea-table-wrap\"><table><thead><tr><th>Laai<\/th><th>Bewyse om te gebruik<\/th><th>Algemene modelleringfout<\/th><\/tr><\/thead><tbody><tr><td>DUoS<\/td><td>Huidige verskafferrekening, DNO-gebied, spanningsvlak, tariefklas en afrekeningsjaar<\/td><td>Om die rooi\/amber\/groen periodes van 'n ander webwerf na te boots of aan te neem dat elke komponent tydens batteryontlading val<\/td><\/tr><tr><td>TNUoS<\/td><td>Behandeling van verskaffers en die huidige NESO-tariefmetode<\/td><td>Om 'n vermindering met die helfte van 'n uur as die verwydering van die hele TNUoS-wetsontwerp te beskou.<\/td><\/tr><tr><td>Triad blootstelling<\/td><td>Wintervoorspelling, werklike drie afrekeningsperiodes en beskikbare battery-SOC<\/td><td>Bespreek die waarde as gewaarborgde inkomste voordat die werklike Triades bekend is.<\/td><\/tr><\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a653d008 auto-p elementor-widget elementor-widget-heading\" data-id=\"a653d008\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">DUoS kan tydgebonde, kapasiteitsgebonde en vaste komponente bevat, en die verskaffer kan dit verskillend saamgroepeer of deurgee. Gebruik die webwerf se huidige tariefskedule in plaas van 'n generiese Britse aanname.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1a590605 auto-p elementor-widget elementor-widget-heading\" data-id=\"1a590605\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Die <a href=\"https:\/\/www.neso.energy\/industry-information\/charging\/tnuos-charges\" target=\"_blank\" rel=\"noopener\">Nasionale energiestelseloperateur<\/a> Definieer Triade as die drie halfuur-nedersettingsperiodes met die hoogste stelselaanvraag. 'n Batery wat vir die verkeerde winteraand gereserveer word, verdien geen Triad-voordeel nie, en een wat reeds aan 'n fabriekspiek toegewys is, mag nie genoeg SOC h\u00ea vir albei take nie. Beskou Triad-ontwyking as 'n terreinspesifieke scenario, nie as 'n gewaarborgde jaarlikse inkomste nie.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d6ef36d5 auto-table elementor-widget elementor-widget-text-editor\" data-id=\"d6ef36d5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"cea-table-wrap\"><table><thead><tr><th>Waarde-stroom<\/th><th>Bewys vereis<\/th><th>Hoofrede waarom die skatting verander<\/th><\/tr><\/thead><tbody><tr><td>Son-selfverbruik<\/td><td>Gelyktydige PV- en lasdata, invoerprys, uitvoerbetaal<\/td><td>Die dak mag minder surplus h\u00ea as wat sy jaarlikse opbrengs aandui.<\/td><\/tr><tr><td>Tydverskuiwing<\/td><td>Energietariewe elke halfuur en laaigeleentheid<\/td><td>Pryisverspreidings en bedryfsure verander<\/td><\/tr><tr><td>Piekvermindering<\/td><td>Halfuurse vraag en die presiese gefaktureerde tarief<\/td><td>'n Kort maksimum mag nie die veronderstelde rekeningspost beheer nie.<\/td><\/tr><tr><td>Bestuur van verbindingskapasiteit<\/td><td>Aansluitingsooreenkoms, voorgestelde nuwe las en versterkingsopsie<\/td><td>Die battery kan werk uitstel sonder om die uiteindelike behoefte te verwyder.<\/td><\/tr><tr><td>Triad blootstelling<\/td><td>Behandeling van verskaffers, wintervoorspelling en beskikbare SOC<\/td><td>Slegs die werklike drie tydperke bepaal die lokasiefooi.<\/td><\/tr><tr><td>Buigsame dienste<\/td><td>Aggregatorvoorwaardes, meetwerk, beskikbaarheid en uitstuurkonflikte<\/td><td>Inkomste en toegang kan gedurende die projeklewe verander.<\/td><\/tr><\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e8dc583f auto-p elementor-widget elementor-widget-heading\" data-id=\"e8dc583f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Die ge\u00efnstalleerde koste kan nie tot een UK-wye \u00a3\/kWh-syfer verminder word nie. Die 215 kWh-buitekas en die 1 MWh-houer dra verskillende siviele werke, bekabeling, transformator, skakelherstel, brandstrategie, kommunikasie en DNO-studie-koste. Vergelyk volledige gelewerde omvang by dieselfde wisselstroomkrag, bruikbare-energie-definisie en bedryfsplig voordat terugverdientyd bereken word. Die <strong><a href=\"https:\/\/www.solidess.com\/af\/bess-lcos-lifetime-cost-per-delivered-kwh\/\" target=\"_blank\" style=\"color:#61ce70\">BESS lewensiklus-koste metode<\/a><\/strong> kan dan toets of 'n laer toerustingprys werklik goedkoper gelewerde energie oplewer.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ff0b5d6e auto-h2 elementor-widget elementor-widget-heading\" data-id=\"ff0b5d6e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Vier insette wat gewoonlik die koopbesluit vervorm<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-55ef42d1 auto-h3 elementor-widget elementor-widget-heading\" data-id=\"55ef42d1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">1. Vermenigvuldiging van son-kWp met 'n vaste batteryverhouding<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c4cfe48f auto-p elementor-widget elementor-widget-heading\" data-id=\"c4cfe48f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Vaste verhoudings ignoreer wanneer die fabriek sonkrag verbruik. Die resultaat kan oor somerweekends heeltemal vol wees, deur die winter deels leeg bly en steeds tydens die aandgeleentheid, waarvoor dit gekoop is om te dek, opraak.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1efcdb88 auto-p elementor-widget elementor-widget-heading\" data-id=\"1efcdb88\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\"><strong>Gebruik eerder:<\/strong> herhaalbare halfuur-oorskot in vergelyking met die latere las wat dit kan verbruik.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1238fc9a auto-h3 elementor-widget elementor-widget-heading\" data-id=\"1238fc9a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">2. Gebruik Grid Invoer as die totale geboubelasting<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-88d56043 auto-p elementor-widget elementor-widget-heading\" data-id=\"88d56043\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Agter-die-meter PV verminder die invoer wat by die netwerkmeter aangedui word. As daardie waarde as die totale terreinbehoefte gelees word, lyk beide die las en die middagsonbydrae kleiner as wat hulle werklik is. Dit kan ook die daling in vraag verberg wat die ontlading van die battery in uitvoer sou omskep.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e7297869 auto-p elementor-widget elementor-widget-heading\" data-id=\"e7297869\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\"><strong>Gebruik eerder:<\/strong> geallineerde PV-omsetterdata, aansluitpuntdata en die relevante interne meter.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-28d2b258 auto-h3 elementor-widget elementor-widget-heading\" data-id=\"28d2b258\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">3. Kies kWh voordat jy die PCS kW nagaan<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d040d0d2 auto-p elementor-widget elementor-widget-heading\" data-id=\"d040d0d2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Deur 400 kWh agter 'n 100 kW-PCS te sit, bly 'n 150 kW-piek steeds deur die PCS beperk. Die battery mag genoeg energie h\u00ea om die gebeurtenis te dek, maar die netwerkmeter sal steeds ten minste 50 kW bo die teiken aanmeld solank daardie gaping voortbestaan.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2639c98f auto-p elementor-widget elementor-widget-heading\" data-id=\"2639c98f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\"><strong>Gebruik eerder:<\/strong> eerstens die maksimum herhaalde kW-gaping, dan die halfuur-gebeurtenisenergie.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5eb10e49 auto-h3 elementor-widget elementor-widget-heading\" data-id=\"5eb10e49\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">4. Bevriesing van die toerusting voordat die DNO-posisie bekend is<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a84b9ba5 auto-p elementor-widget elementor-widget-heading\" data-id=\"a84b9ba5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Die DNO kan die nuwe PCS saam met bestaande PV beoordeel en versoek verskillende uitvoerinstellings, beskerming, studies of versterking. 'n Toerustingbestelling gebaseer op onbeperkte werking kan die stelsel permanent beperk laat of 'n laat herontwerp dwing.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4e793524 auto-p elementor-widget elementor-widget-heading\" data-id=\"4e793524\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\"><strong>Gebruik eerder:<\/strong> Voer die voorgestelde PCS-gradering, bedryfsmodus en beperkingskema deur die koppeling hersiening voordat die sluitingshoeveelhede vasgel\u00ea word. Waar 'n battery bedoel is om 'n onmiddellike transformatorverhoging te vermy, die <strong><a href=\"https:\/\/www.solidess.com\/af\/bess-avoid-transformer-upgrade\/\" target=\"_blank\" style=\"color:#61ce70\">transformator-opgradering beoordeling<\/a><\/strong> verduidelik die bewyslas wat nodig is om die eis te bewys.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3d2150e1 auto-p elementor-widget elementor-widget-heading\" data-id=\"3d2150e1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Verkeerde insette kan die battery bruikbaar laat terwyl die kommersi\u00eble uitslag onvoorspelbaar gemaak word. Kleiner stelsels wat gebaseer is op gemeet perke kan 'n duideliker uitslag lewer as groter kaste wat gekoop is op grond van 'n sonratio of 'n opskrifterugbetalingssyfer.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-717b05a8 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"717b05a8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Die finale produkkeuse volg dieselfde vyf terreinrekords.<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-30bccfc6 auto-p elementor-widget elementor-widget-heading\" data-id=\"30bccfc6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">ESSA0100B-0215 is die direkte kandidaat wanneer die herhaalde PCC-gaping binne 100 kW bly, die geskeduleerde energie in die gewaarborgde bruikbare venster pas en die kas voor die volgende gebeurtenis kan herlaai. Die alles-in-een buiteformaat is geskik vir 'n fabriek wat een gedefinieerde piekvermindering of sonverskuiwingstaak by 400 V benodig.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-187b7390 auto-p elementor-widget elementor-widget-heading\" data-id=\"187b7390\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Die 261,24 kWh vloeistofgekoelde stelsel pas in dieselfde algemene kragklas wanneer die terrein meer energie-reserwe, 'n langer ontladingsperiode of 'n groter voorraad benodig. Die 125 kVA-gradering moet teen werklike krag en kragfaktor nagegaan word. Parallelle uitbreiding is beskikbaar, maar die byvoeging van kaste los 'n energiegebrek slegs op wanneer die PCS-pad, beheerstelsels en aansluitpunt ook die vereiste krag kan dra.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ec076607 auto-p elementor-widget elementor-widget-heading\" data-id=\"ec076607\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">ESSC0500B-1075 behoort te wees waar herhaalde vraag reeds in die enkele honderde kilowatt-reeks is en die elektriese infrastruktuur die blok kan ondersteun. By 400 V verteenwoordig 500 kW ongeveer 722 A by eenheidsmagfaktor voor projekspesifieke toelaes.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3edf3271 auto-p elementor-widget elementor-widget-heading\" data-id=\"3edf3271\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Die ooreenstemmende spanningsetiket op die skakelbord bewys nie dat sy busbane, transformator, beskerming of foutvlak daardie stroom kan hanteer nie. As die bestaande paneel en transformator nie ontwerp is om die bykomende stroom en foutbelasting te dra nie, is die 500 kW-opsie nie aansluitingsgereed nie, selfs al dui beide kante 400 V aan. Gedetailleerde 400 V-integrasie word behandel in die <strong><a href=\"https:\/\/www.solidess.com\/af\/400-v-bss-verbinding-bestaande-skakelbord\/\" target=\"_blank\" style=\"color:#61ce70\">gids vir bestaande sentrale-verbinding<\/a><\/strong>.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-90b06252 auto-p elementor-widget elementor-widget-heading\" data-id=\"90b06252\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Plaas vyf rekords op dieselfde tydlyn voor die keuse van die finale produk:<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d52381d1 elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"d52381d1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">goedgekeurde of voorgestelde invoer- en uitvoerbeperkings;<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">verbindingpuntvraag in halfuurintervalle;<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">PV-uitset oor dieselfde tydintervalle;<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">die bedryfsvenster wat die battery sal bedien;<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Genoeg laaityd en speling om die skedule te herhaal.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-acb454aa auto-p elementor-widget elementor-widget-heading\" data-id=\"acb454aa\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Sodra daardie rekords ooreenstem, is die produkkeuse bewysgebaseerd. MegSolid kan die battery- en PCS-pad voorsien wat die gemeete krag- en energievereiste volg, terwyl die VK-verbindingontwerp steeds die projekspesifieke DNO-aansoek, beskerming, skakelherstel, siviele werke en inbedryfstellingsbewyse benodig.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ed4de27d auto-p elementor-widget elementor-widget-heading\" data-id=\"ed4de27d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">As die resultaat op twee geloofwaardige konfigurasies dui, vergelyk hulle teen dieselfde grense van bruikbare energie, seisoenale skedule en DNO-bedryfslimiet voordat jy die groter stelsel kies.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1d01c741 elementor-tablet-align-center elementor-align-center auto-cta elementor-widget elementor-widget-button\" data-id=\"1d01c741\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"#elementor-action%3Aaction%3Dpopup%3Aopen%26settings%3DeyJpZCI6Ijk0OCIsInRvZ2dsZSI6ZmFsc2V9\" target=\"_blank\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Sien watter 215,04 kWh- of 261,24 kWh-konfigurasie beter by die terrein pas<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-4389bc8d auto-faq e-flex e-con-boxed e-con e-child\" data-id=\"4389bc8d\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-afee4fb4 elementor-widget elementor-widget-heading\" data-id=\"afee4fb4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">VGV<\/h2>\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-ddf857a9 e-con-full e-flex e-con e-child\" data-id=\"ddf857a9\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-63ae01c5 elementor-widget elementor-widget-n-accordion\" data-id=\"63ae01c5\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;default_state&quot;:&quot;all_collapsed&quot;,&quot;max_items_expended&quot;:&quot;one&quot;,&quot;n_accordion_animation_duration&quot;:{&quot;unit&quot;:&quot;ms&quot;,&quot;size&quot;:400,&quot;sizes&quot;:[]}}\" data-widget_type=\"nested-accordion.default\">\n\t\t\t\t\t\t\t<div class=\"e-n-accordion\" aria-label=\"Blokkiemusiekspelers. Maak skakels oop met Enter of Spasie, maak toe met Escape, en navigeer met Pyltjiesleutels\">\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-1670\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"1\" tabindex=\"0\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-1670\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Hoe bepaal jy die grootte van kommersi\u00eble sonkragbatterystoor in die VK? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-1670\" class=\"elementor-element elementor-element-54a53f15 e-con-full e-flex e-con e-child\" data-id=\"54a53f15\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-1670\" class=\"elementor-element elementor-element-33d9c34b e-con-full e-flex e-con e-child\" data-id=\"33d9c34b\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-f2bb719f elementor-widget elementor-widget-heading\" data-id=\"f2bb719f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Gebruik die DNO-invoer- en uitvoergrens om PCS-krag te beperk, bereken die halfuurlike son-oorskot n\u00e1 terreinverbruik, en meet die kW en duur van die lasvenster wat die battery sal dek. Kontroleer of die gekose stelsel voor die volgende geskeduleerde ontlading kan herlaai.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-1671\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"2\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-1671\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Kan batterykapasiteit bereken word op grond van kommersi\u00eble son-kWp? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-1671\" class=\"elementor-element elementor-element-51e44ec8 e-con-full e-flex e-con e-child\" data-id=\"51e44ec8\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-1671\" class=\"elementor-element elementor-element-86b8cfd3 e-con-full e-flex e-con e-child\" data-id=\"86b8cfd3\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-758ec568 elementor-widget elementor-widget-heading\" data-id=\"758ec568\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Son-kWp kan 'n vroe\u00eb skatting van die benodigde kapasiteit ondersteun, maar dit kan nie die aankoopgrootte bepaal nie. Twee persele met dieselfde dak kan baie verskillende daaglikse verbruik, naweekbedryf en wintersurplus h\u00ea. Gelyktydige PV- en lasdata openbaar hoeveel energie werklik beskikbaar is vir berging.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-1672\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"3\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-1672\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Watter halfuurlikse data word benodig vir 'n kommersi\u00eble battery in die VK? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-1672\" class=\"elementor-element elementor-element-0590a9bd e-con-full e-flex e-con e-child\" data-id=\"0590a9bd\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-1672\" class=\"elementor-element elementor-element-304b4933 e-con-full e-flex e-con e-child\" data-id=\"304b4933\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-2f5476c8 elementor-widget elementor-widget-heading\" data-id=\"2f5476c8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Gebruik ten minste 12 maande se invoer- en uitvoeropnames by die aansluitingspunt, in lyn met die PV-inverter-uitset oor dieselfde tydperke. Merk afsluitings, vakansiedae, seisoenale produksie en beplande nuwe laste, sodat 'n abnormale maand nie die grootte van die toerusting bepaal nie.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-1673\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"4\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-1673\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Het 'n kommersi\u00eble battery 'n G99-aansoek nodig? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-1673\" class=\"elementor-element elementor-element-632ac98d e-con-full e-flex e-con e-child\" data-id=\"632ac98d\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-1673\" class=\"elementor-element elementor-element-b8fd4b50 e-con-full e-flex e-con e-child\" data-id=\"b8fd4b50\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-59b065b1 elementor-widget elementor-widget-heading\" data-id=\"59b065b1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Kommersi\u00eble opwekking en berging bo die G98-limiet van 16 A per fase volg gewoonlik G99. Die DNO beoordeel die aggregatie-installasie, insluitend bestaande PV en die beoogde battery-PCS. Aansoekbesonderhede hang af van die stelselgrootte, die aansluitingsspanning en die netwerkoperateur.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-1674\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"5\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-1674\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Wat doen G100 vir batterystoor? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-1674\" class=\"elementor-element elementor-element-33653d0b e-con-full e-flex e-con e-child\" data-id=\"33653d0b\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-1674\" class=\"elementor-element elementor-element-2e182e38 e-con-full e-flex e-con e-child\" data-id=\"2e182e38\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-55fd16fc elementor-widget elementor-widget-heading\" data-id=\"55fd16fc\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">G100 stel vereistes vir kli\u00ebntinvoer- en uitvoerbeperkingskemas. Dit dek meting, beheertoestande, reaksie, foutveilige gedrag, toetsing en rekords. Dit vervang nie G99-goedkeuring nie, en die installering van 'n EMS met 'n uitvoerstelling bewys op sigself nie G100-nakoming nie.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-1675\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"6\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-1675\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Kan 'n battery 'n fabriek onder sy maksimum invoer\u00adkapasiteit hou? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-1675\" class=\"elementor-element elementor-element-4d745d76 e-con-full e-flex e-con e-child\" data-id=\"4d745d76\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-1675\" class=\"elementor-element elementor-element-600ded4e e-con-full e-flex e-con e-child\" data-id=\"600ded4e\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-1d156ad0 elementor-widget elementor-widget-heading\" data-id=\"1d156ad0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Dit kan die gemeete invoer verminder wanneer sy PCS-krag, beskikbare energie en beheerreaksie die las bo die teiken dek. Die ontwerp benodig ook 'n laaivenster onder die invoergrens. Die battery verander nie die kontraktuele kapasiteit nie, tensy die betrokke partye daardie verandering goedkeur.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-1676\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"7\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-1676\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Kan kommersi\u00eble batterystoor sonder uitvoer funksioneer? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-1676\" class=\"elementor-element elementor-element-ee22155a e-con-full e-flex e-con e-child\" data-id=\"ee22155a\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-1676\" class=\"elementor-element elementor-element-161e0182 e-con-full e-flex e-con e-child\" data-id=\"161e0182\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-197bba77 elementor-widget elementor-widget-heading\" data-id=\"197bba77\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Ja, mits die goedgekeurde beheemsem die aansluitpunt meet en die PV- of battery-uitset verminder voordat die uitvoer die ooreengekome limiet oorskry. Die reaksie moet ook veilig bly wanneer die terreinvraag daal, 'n CT misluk of kommunikasie verlore gaan.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-1677\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"8\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-1677\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Is AC-koppeling geskik vir 'n bestaande kommersi\u00eble sonkragstelsel? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-1677\" class=\"elementor-element elementor-element-d66de7c9 e-con-full e-flex e-con e-child\" data-id=\"d66de7c9\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-1677\" class=\"elementor-element elementor-element-aff9e187 e-con-full e-flex e-con e-child\" data-id=\"aff9e187\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-cc3b3c86 elementor-widget elementor-widget-heading\" data-id=\"cc3b3c86\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">AC-koppeling laat dikwels 'n bruikbare PV-omsetter op sy plek bly, terwyl die battery 'n aparte kragstelsel (PCS) gebruik. Die DNO beoordeel steeds die aggregategenerasie- en beperkingsre\u00ebling. Skakelbordkapasiteit, transformatorbelasting, beskerming en beheersko\u00f6rdinering bepaal of die opgradering prakties is.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-1678\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"9\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-1678\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Is 'n 100 kW \/ 215,04 kWh-battery genoeg vir 'n fabriek? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-1678\" class=\"elementor-element elementor-element-5daba49e e-con-full e-flex e-con e-child\" data-id=\"5daba49e\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-1678\" class=\"elementor-element elementor-element-8da41958 e-con-full e-flex e-con e-child\" data-id=\"8da41958\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-4654925d elementor-widget elementor-widget-heading\" data-id=\"4654925d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Dit is 'n kandidaat wanneer die herhaalde kragnet-gaping binne 100 kW bly en die geskeduleerde vereiste vir bruikbare energie binne die produk se gewaarborgde bedryfsvenster val. Langer gebeure, 'n groter reserve of onvoldoende herlaaityd kan 'n ander konfigurasie vereis.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-1679\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"10\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-1679\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Hoe moet 'n Britse besigheid die terugverdientyd van 'n battery skat? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-1679\" class=\"elementor-element elementor-element-b7ce1226 e-con-full e-flex e-con e-child\" data-id=\"b7ce1226\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-1679\" class=\"elementor-element elementor-element-bd9106da e-con-full e-flex e-con e-child\" data-id=\"bd9106da\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-e64b32ff elementor-widget elementor-widget-heading\" data-id=\"e64b32ff\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Modelleer son-selfverbruik, tydsverskuiwing en piekvermindering afsonderlik. Trek opgeofferde uitvoerinkomste, laaikoste, omskakelingsverliese, bykomstigheidsgebruik, onderhoud en battery-slijtage af. Voeg netwerkheffing of buigsaamheidswaarde slegs by waar die terrein se kontrak en bedryfsre\u00ebls dit ondersteun.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-16710\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"11\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-16710\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Wat bepaal die batterystroom in 'n VK C&amp;I-projek? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-16710\" class=\"elementor-element elementor-element-2cae6819 e-con-full e-flex e-con e-child\" data-id=\"2cae6819\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-16710\" class=\"elementor-element elementor-element-95cee0c6 e-con-full e-flex e-con e-child\" data-id=\"95cee0c6\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-d5ae6ab5 elementor-widget elementor-widget-heading\" data-id=\"d5ae6ab5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Batterykrag word verkry uit die grootste herhaalde verskil tussen die gemeet terreinvraag en die gekose invoerdoelwit, onderhewig aan die deur DNO goedgekeurde bedryfsgrense. Die PCS moet daardie kW-gaping dek terwyl dit aan die terrein se spanning-, stroom- en beheervereistes voldoen.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-16711\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"12\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-16711\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Wat bepaal die batterye\u00adenergie in 'n kommersi\u00eble sonkragprojek? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-16711\" class=\"elementor-element elementor-element-d1a4d0e8 e-con-full e-flex e-con e-child\" data-id=\"d1a4d0e8\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-16711\" class=\"elementor-element elementor-element-f0274e60 e-con-full e-flex e-con e-child\" data-id=\"f0274e60\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-32d56231 elementor-widget elementor-widget-heading\" data-id=\"32d56231\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Battery-energie kom van die opgehoopte kWh oor die ontlaaivenster, beperk deur die herhaalbare son- of netwerklaaienergie wat vooraf beskikbaar is. Reserwe, bedryfsgrense en veroudering moet ingesluit word voordat die nominale kapasiteit in skeduleerbare energie omgeskakel word.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-16712\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"13\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-16712\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Watter MegSolid-stelsel is geskik vir kommersi\u00eble sonkragstoor in die VK? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-16712\" class=\"elementor-element elementor-element-f822f9dc e-con-full e-flex e-con e-child\" data-id=\"f822f9dc\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-16712\" class=\"elementor-element elementor-element-67ed2f7a e-con-full e-flex e-con e-child\" data-id=\"67ed2f7a\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-57479c29 elementor-widget elementor-widget-heading\" data-id=\"57479c29\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">ESSA0100B-0215 pas by gemeet vereistes naby 100 kW en 215 kWh nominaal, terwyl die 261,24 kWh vloeistofgekoelde stelsel energie-reserwe in 'n soortgelyke kragklas toevoeg. ESSC0500B-1075 bedien groter terreine slegs nadat die DNO en terreininfrastruktuur 'n 500 kW-blok kan ondersteun.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Bepaal die grootte van 'n VK-kommersi\u00eble sonbatterystoorstelsel deur DNO-invoer- en uitvoerbeperkings, gemeet PV-oorskot en halfuurlikse vraag, en pas dan die resultaat by 'n C&amp;I BESS.<\/p>","protected":false},"author":4,"featured_media":5286,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"_joinchat":[],"footnotes":""},"categories":[27,1],"tags":[609,610,606,605,604,603,607,608],"class_list":["post-5289","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-news","category-bess","tag-battery-storage-export-limitation-uk","tag-battery-storage-for-peak-shaving-uk","tag-behind-the-meter-battery-storage-uk","tag-ci-battery-storage-uk","tag-commercial-battery-storage-uk","tag-commercial-solar-battery-storage-uk","tag-dno-battery-storage-connection","tag-g99-battery-storage-uk"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.solidess.com\/af\/wp-json\/wp\/v2\/posts\/5289","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.solidess.com\/af\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.solidess.com\/af\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.solidess.com\/af\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/www.solidess.com\/af\/wp-json\/wp\/v2\/comments?post=5289"}],"version-history":[{"count":4,"href":"https:\/\/www.solidess.com\/af\/wp-json\/wp\/v2\/posts\/5289\/revisions"}],"predecessor-version":[{"id":5296,"href":"https:\/\/www.solidess.com\/af\/wp-json\/wp\/v2\/posts\/5289\/revisions\/5296"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.solidess.com\/af\/wp-json\/wp\/v2\/media\/5286"}],"wp:attachment":[{"href":"https:\/\/www.solidess.com\/af\/wp-json\/wp\/v2\/media?parent=5289"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.solidess.com\/af\/wp-json\/wp\/v2\/categories?post=5289"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.solidess.com\/af\/wp-json\/wp\/v2\/tags?post=5289"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}