{"id":5540,"date":"2026-09-25T09:55:24","date_gmt":"2026-09-25T01:55:24","guid":{"rendered":"https:\/\/www.solidess.com\/?p=5540"},"modified":"2026-10-08T15:44:01","modified_gmt":"2026-10-08T07:44:01","slug":"ci-battery-bergingsplastiekinspuitgietmasjiene","status":"publish","type":"post","link":"https:\/\/www.solidess.com\/af\/ci-battery-storage-plastic-injection-molding-machines\/","title":{"rendered":"Hou op om kapasiteitsboetes te betaal: C&amp;I-batterystoor vir plastiekinspuitgietmasjiene"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"5540\" class=\"elementor elementor-5540\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-bf4793c e-con-full auto-article-root e-flex e-con e-parent\" data-id=\"bf4793c\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-75b027d7 auto-image elementor-widget elementor-widget-image\" data-id=\"75b027d7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"1254\" height=\"1254\" src=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Injection-Molding-Capacity-Fines-Cover.jpg\" class=\"attachment-1536x1536 size-1536x1536 wp-image-5537\" alt=\"MegSolid C&amp;I-batteryberging vir plastiekinspuitgietmasjiene wat PCC-vraagspitssny van 680 kW tot &#039;n gekontrakteerde limiet van 500 kW toon, met &#039;n 180 kW BESS-ontlaaiverpligting.\" srcset=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Injection-Molding-Capacity-Fines-Cover.jpg 1254w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Injection-Molding-Capacity-Fines-Cover-300x300.jpg 300w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Injection-Molding-Capacity-Fines-Cover-1024x1024.jpg 1024w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Injection-Molding-Capacity-Fines-Cover-150x150.jpg 150w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Injection-Molding-Capacity-Fines-Cover-768x768.jpg 768w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Injection-Molding-Capacity-Fines-Cover-12x12.jpg 12w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Injection-Molding-Capacity-Fines-Cover-600x600.jpg 600w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Injection-Molding-Capacity-Fines-Cover-100x100.jpg 100w\" sizes=\"(max-width: 1254px) 100vw, 1254px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c1f619fd auto-p elementor-widget elementor-widget-heading\" data-id=\"c1f619fd\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Fabrieke vir plastiekinspuitgiet kan lank voor hulle produksieruimte opraak 'n elektriese kapasiteitslimiet bereik. Verskeie vormmasjiene, hidrouliese pompe, silinderverwarmers, verkoelers, droogmiddels en kompressors kan oorvleuel gedurende dieselfde produksietydperk, wat die PCC-vraag bo die gekontrakteerde kapasiteit stoot, selfs wanneer die gemiddelde verbruik hanteerbaar bly. Dit kan lei tot boetes vir oortreding van kapasiteit, ho\u00ebr fooie vir maksimumvraag, of druk om die transformator en nutsverbinding op te gradeer vir pieke wat net 'n deel van die skof duur.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7a541560 auto-p elementor-widget elementor-widget-heading\" data-id=\"7a541560\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">MegSolid C&amp;I-batterystoorvoorsiening dek daardie tydelike gaping agter die meter.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c8183a9a auto-h3 elementor-widget elementor-widget-heading\" data-id=\"c8183a9a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Bereken die kapasiteitsgaping by die PCC<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8ef2b35c auto-p elementor-widget elementor-widget-heading\" data-id=\"8ef2b35c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">As die fabriek 680 kW bereik teenoor 'n gekontrakteerde limiet van 500 kW, het dit 'n <strong>180 kW kapasiteitsoorskrydingprobleem<\/strong>:<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-cb6417ec auto-p elementor-widget elementor-widget-heading\" data-id=\"cb6417ec\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\"><strong>680 kW \u2212 500 kW = 180 kW BESS-ontladingsvereiste<\/strong><\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b8beabe2 auto-p elementor-widget elementor-widget-heading\" data-id=\"b8beabe2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Pas die MegSolid-produkklas by die gemeet gaping: <a href=\"https:\/\/www.solidess.com\/af\/100-kw-215-kwh-buite-kaste-ess\/\" style=\"color:#61ce70\">ESSA0100B-0215<\/a> vir tot 100 kW piekvermindering, <a href=\"https:\/\/www.solidess.com\/af\/product\/megasoliede-soliede-vloeibare-energieberging\/\" style=\"color:#61ce70\">Energon 261<\/a> vir ho\u00ebr kabinetvlak-energie, <a href=\"https:\/\/www.solidess.com\/af\/product\/megsolid-kragomskakelingstelsel\/\" style=\"color:#61ce70\">MEGA PCS<\/a> vir 150\u2013500 kW-pligte, en <a href=\"https:\/\/www.solidess.com\/af\/product\/gekonteineerde-energiebergingsisteem\/\" style=\"color:#61ce70\">ESSC-konteneriseerde BESS<\/a> vir 500 kW\u20131 MW-fabriekswye pieke.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b31be8ac auto-h2 elementor-widget elementor-widget-heading\" data-id=\"b31be8ac\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Kapasiteitsboetes begin met gelyktydige produksieladinge<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2989977c auto-p elementor-widget elementor-widget-heading\" data-id=\"2989977c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Spuitgietmasjiene trek nie deurgaans konstante krag deur elke produksiesiklus nie. Klembeweging, inspuiting, houdruk, skroefherwinning, silinderverhitting, hidrouliese pompe, servostelsels, verkoelers, droogmiddels en kompressors veroorsaak herhalende pieke. Die werklike koste verskyn wanneer verskeie van daardie pieke oorvleuel en die totale fabrieksvraag bo die PCC-limiet stoot.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f4e3ebbb auto-h3 elementor-widget elementor-widget-heading\" data-id=\"f4e3ebbb\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Meet die kragprofiel van die inspuitgietingsiklus<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9c1b2f4a auto-p elementor-widget elementor-widget-heading\" data-id=\"9c1b2f4a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Slegs masjientonnage is nie genoeg om 'n BESS te dimensioner nie. Hidrouliese, servo-hidrouliese en heeltemal elektriese masjiene kan verskillende elektriese profiele h\u00ea, selfs by soortgelyke klemkrag.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4c65624b auto-p elementor-widget elementor-widget-heading\" data-id=\"4c65624b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\"><strong>Groottevolgorde:<\/strong> masjieniklus \u2192 gekombineerde aanlegbelasting \u2192 PCC-piek \u2192 gekontrakteerde kapasiteitsgaping \u2192 vereiste BESS-krag.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-60b231cf auto-p elementor-widget elementor-widget-heading\" data-id=\"60b231cf\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">As die aanleg van 450 kW na 610 kW styg teen 'n 500 kW-limiet, moet die BESS ongeveer 110 kW verwyder. Ho\u00ebrresolusiedata kan wys watter masjiene of bykomstighede die piek veroorsaak het.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a36952be auto-h3 elementor-widget elementor-widget-heading\" data-id=\"a36952be\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Skei motorstarttransi\u00ebnte van vraag- en kapasiteitsfooie<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b399df09 auto-p elementor-widget elementor-widget-heading\" data-id=\"b399df09\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Energieheffings word bereken op grond van kWh, terwyl vraagheffings gebaseer is op die hoogste gemeete kW of kVA oor die nutsmaatskappy se faktureringsinterval. Oortredingsheffings vir kapasiteit geld slegs waar die tarief of aansluitingsooreenkoms 'n boete opl\u00ea vir vraag wat die gekontrakteerde limiet oorskry.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b4c90e42 auto-p elementor-widget elementor-widget-heading\" data-id=\"b4c90e42\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Kort motor-inloop is nie outomaties 'n 15-minuut-vraaggebeurtenis nie. Die kommersi\u00eble probleem is volgehoue of herhaalde ho\u00eb las. As die aanleg 620 kW bereik teen 'n 500 kW-limiet, moet die BESS ongeveer 120 kW voorsien.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ff9ee081 auto-p elementor-widget elementor-widget-heading\" data-id=\"ff9ee081\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">MegSolid <a href=\"https:\/\/www.solidess.com\/af\/battery-peak-shaving-control-pcc\/\" style=\"color:#61ce70\">PCC piekvlakbeheer<\/a> Rig op daardie presiese verskil in plaas daarvan om by 'n arbitr\u00eare vaste krag af te vuur.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2e1878d4 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"2e1878d4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Gebruik C&amp;I-batterystoor om die PCC-invoer onder die gekontrakteerde limiet te hou<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7371b209 auto-image elementor-widget elementor-widget-image\" data-id=\"7371b209\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"1448\" height=\"1086\" src=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Injection-Molding-Peak-Shaving-Engineering-Proof.jpg\" class=\"attachment-1536x1536 size-1536x1536 wp-image-5539\" alt=\"MegSolid-produkroeteringsbesluit vir inspuitgieterye deur ESSA0100B-0215, Energon 261, MEGA PCS en ESSC-konteneriseerde BESS te vergelyk op grond van gemeet piekvermindering, kVA-diens, gebeurtenisduur en herlaaivenster.\" srcset=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Injection-Molding-Peak-Shaving-Engineering-Proof.jpg 1448w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Injection-Molding-Peak-Shaving-Engineering-Proof-300x225.jpg 300w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Injection-Molding-Peak-Shaving-Engineering-Proof-1024x768.jpg 1024w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Injection-Molding-Peak-Shaving-Engineering-Proof-768x576.jpg 768w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Injection-Molding-Peak-Shaving-Engineering-Proof-16x12.jpg 16w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Injection-Molding-Peak-Shaving-Engineering-Proof-600x450.jpg 600w\" sizes=\"(max-width: 1448px) 100vw, 1448px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f4d8a4aa auto-p elementor-widget elementor-widget-heading\" data-id=\"f4d8a4aa\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Die BESS sit agter die meter en voorsien die gedeelte van die fabrieksvraag wat bo die gekose net-invoerlimiet l\u00ea. Die oortollige krag word dan 'n beheerste kragdoelwit by die PCC.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-978faa0d auto-h3 elementor-widget elementor-widget-heading\" data-id=\"978faa0d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Beheer piekvlakafname vanaf die PCC<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c722567d auto-p elementor-widget elementor-widget-heading\" data-id=\"c722567d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\"><strong>Beheerketting:<\/strong> PCC-meter \u2192 EMS \u2192 PCS \u2192 batteryontlading \u2192 laer netinvoer.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4a4e6331 auto-p elementor-widget elementor-widget-heading\" data-id=\"4a4e6331\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">As die vraag die plafon nader, verhoog die PCS die afvoer; as die vraag daal, daal die uitset. Herlaai moet binne die beskikbare hoofruimte van die netwerk bly.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3a2c679a auto-p elementor-widget elementor-widget-heading\" data-id=\"3a2c679a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">PCS-krag van 100 kW kan nie 'n volgehoue oortreding van 170 kW verwyder nie. MegSolid MEGA PCS-krag moet ooreenstem met die werklike fabriekstekort, terwyl <a href=\"https:\/\/www.solidess.com\/af\/bess-ems-prioriteitslogika\/\" style=\"color:#61ce70\">EMS-prioriteitslogika<\/a> ko\u00f6rdineer piekvlakverwydering, laai, SOC en ander bedryfsbeperkings.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-15cdba13 auto-h3 elementor-widget elementor-widget-heading\" data-id=\"15cdba13\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Gebruik BESS as 'n tydelike kapasiteitsbuffer voordat die netwerk opgegradeer word.<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-96e8afbf auto-p elementor-widget elementor-widget-heading\" data-id=\"96e8afbf\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Stel jou voor dat 'n bestaande aanleg 'n piek van 720 kW bereik, 'n gekontrakteerde limiet van 800 kW het, en dat 'n nuwe vormmasjien gedurende die kritieke produksietydperk 160 kW byvoeg.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-80628382 auto-p elementor-widget elementor-widget-heading\" data-id=\"80628382\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\"><strong>720kW + 160kW = 880kW<\/strong><\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7ded2d49 auto-p elementor-widget elementor-widget-heading\" data-id=\"7ded2d49\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\"><strong>Resulterende kapasiteitsgaping:<\/strong> 880kW \u2212 800kW = <strong>80kW<\/strong>.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d606328b auto-p elementor-widget elementor-widget-heading\" data-id=\"d606328b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">BESS-ontlading wat daardie 80 kW kan voorsien om PCC-invoer tydens die gebeurtenis by ongeveer 800 kW te hou en 'n nutsside-opgradering uit te stel.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-75b3b0e1 auto-p elementor-widget elementor-widget-heading\" data-id=\"75b3b0e1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">BESS verminder die invoer vanaf die netwerk. Interne kabels, busbane, skakelaars en transformators moet steeds die werklike fabriekslas kan dra.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-04789535 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"04789535\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Grootte PCS-krag, kVA en batteryenergie van die fabriek afduty<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-06ae5f1c auto-h3 elementor-widget elementor-widget-heading\" data-id=\"06ae5f1c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Begin met AC-belasting voor battery-kWh<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3645cad8 auto-p elementor-widget elementor-widget-heading\" data-id=\"3645cad8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Begin met vier insette: vereiste kW, vereiste kVA, piekduur en herlaaivenster. Die battery-naamplaat-kWh kom n\u00e1 daardie waardes.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-68406e43 auto-p elementor-widget elementor-widget-heading\" data-id=\"68406e43\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">MegSolid se <a href=\"https:\/\/www.solidess.com\/af\/batterye\/ci-energieberging\/\" style=\"color:#61ce70\">C&amp;I-energiebergingsportefeulje<\/a> Dek kabinet-, PCS- en gekontainerde kragvlakke vir hierdie verskillende pligte.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e2d138a3 auto-h3 elementor-widget elementor-widget-heading\" data-id=\"e2d138a3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Skei piekvlakvermindering van gebeurtenisenergie<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-123f6914 auto-p elementor-widget elementor-widget-heading\" data-id=\"123f6914\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Krag bepaal hoeveel van die piek die BESS kan verwyder; energie bepaal hoe lank dit daardie vermindering kan handhaaf.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4e2d49a3 auto-p elementor-widget elementor-widget-heading\" data-id=\"4e2d49a3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">'n Piekvermindering van 90 kW vir 20 minute benodig ongeveer 30 kWh voor marge; dieselfde vermindering van 90 kW vir twee uur benodig ongeveer 180 kWh.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e6c1da12 auto-table elementor-widget elementor-widget-text-editor\" data-id=\"e6c1da12\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"cea-table-wrap\"><table><thead><tr><th>Kaste<\/th><th>Geopenbaarde krag \/ energie<\/th><th>Battery \/ verkoeling<\/th><th>Kiesnota<\/th><\/tr><\/thead><tbody><tr><td>ESSA0100B-0215<\/td><td>100kW \/ 215,04kWh<\/td><td>280Ah LFP, 768V nominaal gelykstroom, 0,5C by 25\u00b0C, lugafkoeling, IP54<\/td><td>Direkte kasklas vir pligte tot 100 kW wanneer bruikbare energie die gebeurtenistoets slaag<\/td><\/tr><tr><td>Energon 261<\/td><td>125kVA \/ 261,24kWh<\/td><td>314Ah LFP, 832V nominale gelykstroom, vloeibare verkoeling, IP54<\/td><td>125 kVA moet nie as 'n vaste 125 kW-uitset beskou word nie.<\/td><\/tr><\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a51d13f8 auto-h3 elementor-widget elementor-widget-heading\" data-id=\"a51d13f8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Grootte PCS kW en kVA vir motorbelasting<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1bddbadc auto-p elementor-widget elementor-widget-heading\" data-id=\"1bddbadc\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Spuitgietaanlegte sluit motors, pompe, verkoelers en kompressors in, dus moet die PCS-grootte beide kW en kVA in ag neem.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9b96ff5f auto-p elementor-widget elementor-widget-heading\" data-id=\"9b96ff5f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">MEGA PCS-omslag <strong>30\u2013500kW<\/strong>, met 'n 400 V wisselstroomkoppelvlak, aktiewe\/reaktiewe kragbeheer, ingeboude isolasie-transformator en 'n op-net THDi onder 3%.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-bb7d8600 auto-p elementor-widget elementor-widget-heading\" data-id=\"bb7d8600\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Aanlegte wat 180 kW aan volgehoue piekvermindering benodig, beweeg verby 'n 100 kW PCS na 'n groter, ingenieursgewys ontwerpte kragstadium. Batery-kWh kan nie onvoldoende PCS-krag of kVA kompenseer nie.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-196e7bd6 auto-h3 elementor-widget elementor-widget-heading\" data-id=\"196e7bd6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Pas termiese bestuur en veiligheidsargitektuur by die gekose produk aan.<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-80be5795 auto-p elementor-widget elementor-widget-heading\" data-id=\"80be5795\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">ESSA0100B-0215 gebruik lugafkoeling, Energon 261 gebruik vloeistofafkoeling, en ESSC-gekonteneriseerde stelsels gebruik temperatuurbeheerde lugafkoeling.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-de3cfdf3 auto-p elementor-widget elementor-widget-heading\" data-id=\"de3cfdf3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">ESSC0500B-1075 verskaf <strong>500kW \/ 1.0752MWh<\/strong>, terwyl ESSC1000B-2150 verskaf <strong>1MW \/ 2,1504MWh<\/strong>.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7ac08957 auto-p elementor-widget elementor-widget-heading\" data-id=\"7ac08957\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Projekveiligheid kan, waar van toepassing op die bestemmingsmark en die bevoegde owerheid, verwys na IEC 62619, UL 9540, UL 9540A en NFPA 855.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-20c1f644 elementor-tablet-align-center elementor-align-center auto-cta elementor-widget elementor-widget-button\" data-id=\"20c1f644\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"#elementor-action%3Aaction%3Dpopup%3Aopen%26settings%3DeyJpZCI6Ijk0OCIsInRvZ2dsZSI6ZmFsc2V9\" target=\"_blank\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Stuur 15-minuut fabriekslasdata vir 'n gratis laskrommes-analise en BESS-groottebeoordeling<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-58b10724 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"58b10724\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Bou die finansi\u00eble saak op grond van die werklike tarief en opgraderingskoste<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-01a8d291 auto-p elementor-widget elementor-widget-heading\" data-id=\"01a8d291\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Die finansi\u00eble saak moet begin met 'n factureerbare piek en die werklike tarief.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f0823523 auto-h3 elementor-widget elementor-widget-heading\" data-id=\"f0823523\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Bereken besparings op aanvraagfooi vanaf die gemeteerde piek<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c7212650 auto-p elementor-widget elementor-widget-heading\" data-id=\"c7212650\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">As 'n aanleg 'n gefaktureerde piek van 500 kW met 300 kW verminder by 'n vraagkoers van $20\/kW, is die berekende resultaat:<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-053e865b elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"053e865b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>Maandelikse:<\/strong> 300kW \u00d7 $20\/kW = <strong>$6,000<\/strong><\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>Twaalf vergelykbare faktureringsperiodes:<\/strong> $6,000 \u00d7 12 = <strong>$72,000 per jaar<\/strong><\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-216d581b auto-p elementor-widget elementor-widget-heading\" data-id=\"216d581b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Die syfer van $72,000 dek slegs die vermindering van aanvraagheffings. Voeg kapasiteitsoverschrijdingsheffings of uitgestelde netwerkwerk afsonderlik by waar dit werklik van toepassing is, deur die werklike tarief en faktureringsinterval te gebruik.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-cedcb702 auto-h3 elementor-widget elementor-widget-heading\" data-id=\"cedcb702\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Pas aansporings toe nadat die elektriese stelsel grootte bepaal is.<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7ba5cdd0 auto-p elementor-widget elementor-widget-heading\" data-id=\"7ba5cdd0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">In aanmerking komende Amerikaanse projekte kan die belastingkrediet vir skoon elektrisiteit ingevolge Artikel 48E en versnelde afskrywing in die finansi\u00eble model insluit.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-609e4b31 auto-p elementor-widget elementor-widget-heading\" data-id=\"609e4b31\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\"><strong>Finansi\u00eble volgorde:<\/strong> kapasiteitsprobleem \u2192 PCS-krag \u2192 batterye-energie \u2192 ge\u00efnstalleerde koste \u2192 bedryfsbesparings \u2192 aansporings.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7897e86c auto-p elementor-widget elementor-widget-heading\" data-id=\"7897e86c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Hierdie bevel verhoed dat die finansi\u00eble model die aanleg na 'n oorgroot battery dryf.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f4755364 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"f4755364\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Gebruik sekond\u00eare dienste slegs nadat piekvlakvermindering voltooi is en die SOC beskerm is.<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-fb4e0fb8 auto-p elementor-widget elementor-widget-heading\" data-id=\"fb4e0fb8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Piekvlakvermindering bly die prim\u00eare taak. Rugsteun- en sonkrag moet dit ondersteun, nie die krag of die SOC verbruik wat nodig is om die kapasiteitslimiet te beheer nie.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-11c82826 auto-h3 elementor-widget elementor-widget-heading\" data-id=\"11c82826\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Kragkwaliteit en beskerming teen mikro-onderbrekings<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-854f6ddf auto-p elementor-widget elementor-widget-heading\" data-id=\"854f6ddf\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Kort onderbrekings kan PLC's, pompe, verkoeling, materiaalhantering en prosesbeheer ontwrig, wat stilstand veroorsaak wat baie langer duur as die ontwrigting self.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ed849c1b auto-p elementor-widget elementor-widget-heading\" data-id=\"ed849c1b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Backingup vereis doelbewuste roosterseparasie, oordragtoerusting, 'n beskermde-lasbus, geskikte PCS-bedryf, voldoende kVA en 'n gereserveerde SOC.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c3515f63 auto-p elementor-widget elementor-widget-heading\" data-id=\"c3515f63\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Die beskerming van beheerstelsels, verkoeling en beheerde afsluitingslaste kan meer doeltreffend wees as om elke vormmasjien te rugsteun. MegSolid se <a href=\"https:\/\/www.solidess.com\/af\/netgekoppelde-batterypakket-waarom-bess-afskakel-by-kragonderbreking\/\" style=\"color:#61ce70\">Uitvalgids vir roostergekoppelde BESS<\/a> verduidelik hierdie grens.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a0131c0e auto-h3 elementor-widget elementor-widget-heading\" data-id=\"a0131c0e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Sinergi\u00eb met daksonpaneelstelsels<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-50a403c3 auto-p elementor-widget elementor-widget-heading\" data-id=\"50a403c3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Dak-PV kan die dagtydse inkoop van die netwerk verminder, terwyl die BESS oortollige opwekking stoor of energie bewaar vir die produksiepiek.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6e844fe4 auto-p elementor-widget elementor-widget-heading\" data-id=\"6e844fe4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Sonlading mag nie die PCC bo die gekontrakteerde limiet stoot nie, en die groottebepaling van BESS moet steeds die werklike kapasiteitstekort volg. <a href=\"https:\/\/www.solidess.com\/af\/hoe-om-bess-nul-uitvoerbeheer-by-die-pcc-te-spesifiseer\/\" style=\"color:#61ce70\">PCC geen-uitvoerkontrole<\/a> Kan PV- en batterybedryf ko\u00f6rdineer waar uitvoer beperk is.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-50ef23e1 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"50ef23e1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Pas die MegSolid-platform aan by die gemeet kapasiteitsgaping<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-440c2906 auto-image elementor-widget elementor-widget-image\" data-id=\"440c2906\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"1448\" height=\"1086\" src=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Injection-Molding-MegSolid-Product-Route-Decision.jpg\" class=\"attachment-1536x1536 size-1536x1536 wp-image-5538\" alt=\"Ingenieursbewys vir piekvyl by inspuitgiet, wat die groottevolgorde, PCC-beheer, piekvyl-beheerketting, krag teenoor gebeurtenisenergie en &#039;n voorbeeld van &#039;n 80 kW tydelike kapasiteitsbuffer toon.\" srcset=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Injection-Molding-MegSolid-Product-Route-Decision.jpg 1448w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Injection-Molding-MegSolid-Product-Route-Decision-300x225.jpg 300w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Injection-Molding-MegSolid-Product-Route-Decision-1024x768.jpg 1024w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Injection-Molding-MegSolid-Product-Route-Decision-768x576.jpg 768w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Injection-Molding-MegSolid-Product-Route-Decision-16x12.jpg 16w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Injection-Molding-MegSolid-Product-Route-Decision-600x450.jpg 600w\" sizes=\"(max-width: 1448px) 100vw, 1448px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f3de1921 auto-p elementor-widget elementor-widget-heading\" data-id=\"f3de1921\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Plastiekinspuitgieterye behoort nie voort te gaan om boetes vir betaalvermo\u00eb te betaal of masjienuitbreiding te vertraag nie omdat kort produksiepieke die roostersgrens oorskry.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-873d2578 auto-p elementor-widget elementor-widget-heading\" data-id=\"873d2578\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\"><strong>Groottebepalingspad:<\/strong> Meet die PCC \u2192 identifiseer die gekontrakteerde limiet \u2192 bereken die oortollige kW\/kVA \u2192 meet die duur \u2192 verifieer die herlaai \u2192 kies die MegSolid-stelsel.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-29fa5140 auto-h3 elementor-widget elementor-widget-heading\" data-id=\"29fa5140\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Produkgrens volgens gemeet piekvermindering<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4bcbfdd5 elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"4bcbfdd5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>Tot 100 kW:<\/strong> ESSA0100B-0215 wanneer bruikbare energie die gebeurtenis dek.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>Ho\u00ebr kabinetvlak-energie \/ 125 kVA vloeistofgekoelde platform:<\/strong> Energon 261.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>150\u2013500 kW ingenieurspligte:<\/strong> MEGA PCS met afsonderlik groottebepaalde batterye-energie.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>500 kW\u20131 MW-fabriekswye pieke:<\/strong> ESSC-konteneriseerde stelsels.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f5d3dc51 auto-h3 elementor-widget elementor-widget-heading\" data-id=\"f5d3dc51\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Kontak MegSolid met die fabriekslaaigegewys<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7ba3b8fd auto-p elementor-widget elementor-widget-heading\" data-id=\"7ba3b8fd\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Stuur die intervalbelastingdata, gekontrakteerde kapasiteit, PCC-piek, kragfaktor, masjienklassifikasies, produksieskedule, beplande byvoegings en enkellynskets om die PCS-krag, batteryeenergie, herlaai en produkroete te bepaal.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5428f55a elementor-tablet-align-center elementor-align-center auto-cta elementor-widget elementor-widget-button\" data-id=\"5428f55a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"#elementor-action%3Aaction%3Dpopup%3Aopen%26settings%3DeyJpZCI6Ijk0OCIsInRvZ2dsZSI6ZmFsc2V9\" target=\"_blank\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Dien die 15-minuut vragprofiel in \u2014 ontvang 'n gratis vragkrommes-analise en 'n BESS-keuse ROI-verslag<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-050b0a88 auto-faq e-flex e-con-boxed e-con e-child\" data-id=\"050b0a88\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-6eb7b8d7 elementor-widget elementor-widget-heading\" data-id=\"6eb7b8d7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">VGV<\/h2>\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-5d7d85bf e-con-full e-flex e-con e-child\" data-id=\"5d7d85bf\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-95db2bcf elementor-widget elementor-widget-n-accordion\" data-id=\"95db2bcf\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;default_state&quot;:&quot;all_collapsed&quot;,&quot;max_items_expended&quot;:&quot;one&quot;,&quot;n_accordion_animation_duration&quot;:{&quot;unit&quot;:&quot;ms&quot;,&quot;size&quot;:400,&quot;sizes&quot;:[]}}\" data-widget_type=\"nested-accordion.default\">\n\t\t\t\t\t\t\t<div class=\"e-n-accordion\" aria-label=\"Blokkiemusiekspelers. Maak skakels oop met Enter of Spasie, maak toe met Escape, en navigeer met Pyltjiesleutels\">\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2510\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"1\" tabindex=\"0\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2510\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Kan C&amp;I-batterystoor kapasiteitsboetes in 'n plastiekinspuitgietfabriek verminder? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2510\" class=\"elementor-element elementor-element-e1bc1b1c e-con-full e-flex e-con e-child\" data-id=\"e1bc1b1c\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2510\" class=\"elementor-element elementor-element-37515529 e-con-full e-flex e-con e-child\" data-id=\"37515529\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-9c78a7d9 elementor-widget elementor-widget-heading\" data-id=\"9c78a7d9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Ja. PCC-beheerde BESS-bedryf kan die netwerkinvoer onder die gekontrakteerde limiet hou wanneer die stelsel ontwerp is om die gemeete oortredingsgaping te dek.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2511\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"2\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2511\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Is 'n 100 kW BESS genoeg vir 'n inspuitgietaanleg? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2511\" class=\"elementor-element elementor-element-831be53a e-con-full e-flex e-con e-child\" data-id=\"831be53a\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2511\" class=\"elementor-element elementor-element-ccd9a73a e-con-full e-flex e-con e-child\" data-id=\"ccd9a73a\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-df8756e2 elementor-widget elementor-widget-heading\" data-id=\"df8756e2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Ja, wanneer die vereiste piekvermindering binne 100 kW bly en die bruikbare batteryeenergie die gebeurtenis kan handhaaf.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2512\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"3\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2512\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Moet 'n inspuitgietaanleg ESSA0100B-0215 of Energon 261 gebruik? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2512\" class=\"elementor-element elementor-element-952237b2 e-con-full e-flex e-con e-child\" data-id=\"952237b2\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2512\" class=\"elementor-element elementor-element-35620f92 e-con-full e-flex e-con e-child\" data-id=\"35620f92\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-46425882 elementor-widget elementor-widget-heading\" data-id=\"46425882\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Gebruik ESSA0100B-0215 vir 'n piekvermindering tot 100 kW. Gebruik Energon 261 wanneer meer kasvlakenergie, 125 kVA wisselstroomuitset en vloeibare verkoeling benodig word.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2513\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"4\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2513\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Kan batterystoor 'n transformator- of netwerkkapasiteitsopgradering vermy? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2513\" class=\"elementor-element elementor-element-0f0095e8 e-con-full e-flex e-con e-child\" data-id=\"0f0095e8\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2513\" class=\"elementor-element elementor-element-0c6bca0d e-con-full e-flex e-con e-child\" data-id=\"0c6bca0d\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-4dc18aa3 elementor-widget elementor-widget-heading\" data-id=\"4dc18aa3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Ja, wanneer die probleem 'n kortstondige PCC-piek is eerder as 'n voortdurende tekort aan elektriese kapasiteit.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2514\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"5\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2514\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Watter data benodig MegSolid om BESS vir inspuitgietmasjiene te dimensioneren? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2514\" class=\"elementor-element elementor-element-019cca0b e-con-full e-flex e-con e-child\" data-id=\"019cca0b\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2514\" class=\"elementor-element elementor-element-3fc67037 e-con-full e-flex e-con e-child\" data-id=\"3fc67037\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-f2e6bc19 elementor-widget elementor-widget-heading\" data-id=\"f2e6bc19\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Stuur intervalbelastingdata, gekontrakteerde kW of kVA, maksimum PCC-vraag, kragfaktor, hoofmasjienspesifikasies, produksieskedule, beplande uitbreiding en die elektriese enkellynskema.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Stop kapasiteitsboetes en vraagtariefpieke van plastiekinspuitgietmasjiene met MegSolid C&amp;I-batterystoorruimte wat afgestem is op werklike fabrieks-kW, kVA en produksiesiklusse.<\/p>","protected":false},"author":4,"featured_media":5537,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"_joinchat":[],"footnotes":""},"categories":[1,714],"tags":[715,718,721,717,298,720,719,688,716],"class_list":["post-5540","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-bess","category-ci-battery-storage-solutions","tag-ci-battery-storage-for-plastic-injection-molding-machines","tag-capacity-fines-bess","tag-essc-containerized-bess","tag-injection-molding-peak-shaving","tag-mega-pcs","tag-megsolid-energon-261","tag-megsolid-essa0100b-0215","tag-pcc-peak-shaving","tag-plastic-injection-molding-battery-storage"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.solidess.com\/af\/wp-json\/wp\/v2\/posts\/5540","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.solidess.com\/af\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.solidess.com\/af\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.solidess.com\/af\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/www.solidess.com\/af\/wp-json\/wp\/v2\/comments?post=5540"}],"version-history":[{"count":4,"href":"https:\/\/www.solidess.com\/af\/wp-json\/wp\/v2\/posts\/5540\/revisions"}],"predecessor-version":[{"id":5560,"href":"https:\/\/www.solidess.com\/af\/wp-json\/wp\/v2\/posts\/5540\/revisions\/5560"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.solidess.com\/af\/wp-json\/wp\/v2\/media\/5537"}],"wp:attachment":[{"href":"https:\/\/www.solidess.com\/af\/wp-json\/wp\/v2\/media?parent=5540"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.solidess.com\/af\/wp-json\/wp\/v2\/categories?post=5540"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.solidess.com\/af\/wp-json\/wp\/v2\/tags?post=5540"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}