{"id":4988,"date":"2026-08-27T16:48:38","date_gmt":"2026-08-27T08:48:38","guid":{"rendered":"https:\/\/www.solidess.com\/?p=4988"},"modified":"2026-08-27T16:48:38","modified_gmt":"2026-08-27T08:48:38","slug":"supernode-stage-3-bess-sizing","status":"publish","type":"post","link":"https:\/\/www.solidess.com\/ar\/supernode-stage-3-bess-sizing\/","title":{"rendered":"Supernode Stage 3 BESS sizing: Converting 260MW \/ 1,216MWh into an equipment architecture"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"4988\" class=\"elementor elementor-4988\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-bf4793c e-con-full auto-article-root e-flex e-con e-parent\" data-id=\"bf4793c\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-966c6fe4 auto-p elementor-widget elementor-widget-heading\" data-id=\"966c6fe4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Supernode Stage 3 is a clean sizing stress test for Australian buyers. Public figures put it at <strong>260MW \/ 1,216MWh<\/strong>. MegSolid\u2019s standard 5000INTL container lists <strong>2.7MW \/ 5,015.9kWh<\/strong>.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f295c321 auto-p elementor-widget elementor-widget-heading\" data-id=\"f295c321\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Divide both ways and the counts refuse to match. Power-first needs <strong>97<\/strong> standard 5000INTL units. Energy-first needs <strong>243<\/strong>.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-79143e22 auto-p elementor-widget elementor-widget-heading\" data-id=\"79143e22\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">That gap is the point. Split the job into four boundaries before you buy boxes: POI power, delivered energy, installed battery energy and PCS capacity. Then decide whether a standard integrated block fits, whether its AC side would sit idle, or whether the plant needs a different DC\/AC layout.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8b61a926 auto-image elementor-widget elementor-widget-image\" data-id=\"8b61a926\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"960\" height=\"960\" src=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/Supernode-Stage-3-BESS-Sizing-MegSolid-5000INTL.png\" class=\"attachment-1536x1536 size-1536x1536 wp-image-4985\" alt=\"Supernode Stage 3 BESS sizing with the real MegSolid 5000INTL at a Queensland transmission substation\" srcset=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/Supernode-Stage-3-BESS-Sizing-MegSolid-5000INTL.png 960w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/Supernode-Stage-3-BESS-Sizing-MegSolid-5000INTL-300x300.png 300w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/Supernode-Stage-3-BESS-Sizing-MegSolid-5000INTL-150x150.png 150w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/Supernode-Stage-3-BESS-Sizing-MegSolid-5000INTL-768x768.png 768w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/Supernode-Stage-3-BESS-Sizing-MegSolid-5000INTL-12x12.png 12w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/Supernode-Stage-3-BESS-Sizing-MegSolid-5000INTL-600x600.png 600w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/Supernode-Stage-3-BESS-Sizing-MegSolid-5000INTL-100x100.png 100w\" sizes=\"(max-width: 960px) 100vw, 960px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9d222ec0 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"9d222ec0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Fast-scan sizing result<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-cbe7f6b0 auto-table elementor-widget elementor-widget-text-editor\" data-id=\"cbe7f6b0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"cea-table-wrap\"><table><thead><tr><th>Decision input<\/th><th>Published or calculated value<\/th><th>\u0645\u0639\u0646\u0649 \u0645\u0635\u0637\u0644\u062d \u00ab\u0627\u0644\u0645\u0634\u062a\u0631\u064a\u0627\u062a\u00bb<\/th><\/tr><\/thead><tbody><tr><td>Supernode Stage 3 power<\/td><td>260MW<\/td><td>Project-level AC delivery rating reported by GE Vernova<\/td><\/tr><tr><td>Supernode Stage 3 energy<\/td><td>1,216MWh<\/td><td>Published Stage 3 energy; public releases do not define every measurement boundary<\/td><\/tr><tr><td>Nameplate energy-to-power ratio<\/td><td>4.68 hours<\/td><td>More energy than a pure 260MW \u00d7 4h block<\/td><\/tr><tr><td>Exact four-hour delivery energy<\/td><td>1,040MWh<\/td><td>Energy if 260MW is held for exactly four hours<\/td><\/tr><tr><td>Published energy above 1,040MWh<\/td><td>176MWh<\/td><td>Possible margin; allocation needs contract and design evidence<\/td><\/tr><tr><td>5000INTL standard rating<\/td><td>2.7MW \/ 5.0159MWh<\/td><td>About 1.86 hours at nameplate power<\/td><\/tr><tr><td>Power-first 5000INTL count<\/td><td>97 units<\/td><td>About 260MW, only about 486.5MWh of nameplate energy<\/td><\/tr><tr><td>Energy-first 5000INTL count<\/td><td>243 units<\/td><td>About 1,218.9MWh, 656.1MW of listed aggregate AC power<\/td><\/tr><\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0c910a42 auto-p elementor-widget elementor-widget-heading\" data-id=\"0c910a42\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">This is a pre-FEED screen. It is not a Supernode equipment bid. Supernode chose CATL battery systems and GE Vernova for power conversion, plant controls, integration and grid-connection support.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c57551d9 auto-image elementor-widget elementor-widget-image\" data-id=\"c57551d9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/Power-First-vs-Energy-First-BESS-Sizing.png\" class=\"attachment-1536x1536 size-1536x1536 wp-image-4986\" alt=\"Power-first 97-unit and energy-first 243-unit BESS sizing paths for a 260MW 1,216MWh project\" srcset=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/Power-First-vs-Energy-First-BESS-Sizing.png 1024w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/Power-First-vs-Energy-First-BESS-Sizing-300x225.png 300w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/Power-First-vs-Energy-First-BESS-Sizing-768x576.png 768w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/Power-First-vs-Energy-First-BESS-Sizing-16x12.png 16w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/Power-First-vs-Energy-First-BESS-Sizing-600x450.png 600w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5a7e2291 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"5a7e2291\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">What Supernode Stage 3 has publicly confirmed<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-480a8f2b auto-p elementor-widget elementor-widget-heading\" data-id=\"480a8f2b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">GE Vernova\u2019s 21 August 2026 release rates Stage 3 at <strong>260MW \/ 1,216MWh<\/strong> and calls it four-hour storage. The same note puts the finished three-stage campus at <strong>780MW \/ 3,075MWh<\/strong> at Brendale.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-18c13269 auto-p elementor-widget elementor-widget-heading\" data-id=\"18c13269\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Stage 3 has Generator Performance Standards acceptance. GE Vernova supplies PCS, plant controls, integration and grid-connection support, and calls Stage 3 its first grid-forming BESS project in Australia. That is GE Vernova\u2019s Australian record. It is not a claim that this is the first grid-forming battery in the country.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e37d1296 auto-p elementor-widget elementor-widget-heading\" data-id=\"e37d1296\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Primary source for Stage 3 power, energy, GPS and grid-forming wording: <a href=\"https:\/\/www.gevernova.com\/news\/press-releases\/ge-vernova-supports-quinbrook-deliver-all-three-stages-one-australias-largest\" target=\"_blank\" rel=\"noopener\">GE Vernova announcement<\/a>.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1a4f6160 auto-p elementor-widget elementor-widget-heading\" data-id=\"1a4f6160\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">\u0627\u0644\u0640 <a href=\"https:\/\/www.quinbrook.com\/news-insights\/supernode-stage-2-completes-construction-and-commences-operations\/\" target=\"_blank\" rel=\"noopener\">Quinbrook Stage 2 note<\/a> puts Stages 1 and 2 in operation at <strong>520MW \/ 1,858MWh<\/strong>. Stage 3 closed about <strong>AU$469 million<\/strong> of debt and carries a 15-year offtake with Stanwell.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6ba913fb auto-p elementor-widget elementor-widget-heading\" data-id=\"6ba913fb\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\"><a href=\"https:\/\/www.catl.com\/en\/news\/6951.html\" target=\"_blank\" rel=\"noopener\">CATL\u2019s Supernode note<\/a> says EnerC Plus went into Stages 1 and 2 and TENER S into Stage 3, under a long-term service arrangement. CATL lists the three-stage total as <strong>780MW \/ 3,074MWh<\/strong> \u2014 one MWh under the GE Vernova figure.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-079b7adc auto-table elementor-widget elementor-widget-text-editor\" data-id=\"079b7adc\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"cea-table-wrap\"><table><thead><tr><th>Source<\/th><th>Current published total<\/th><th>How to use it<\/th><\/tr><\/thead><tbody><tr><td>GE Vernova, 21 August 2026<\/td><td>780MW \/ 3,075MWh<\/td><td>PCS, controls, GPS, grid-forming scope<\/td><\/tr><tr><td>CATL, 14 August 2026<\/td><td>780MW \/ 3,074MWh<\/td><td>Battery supply and lifecycle service<\/td><\/tr><tr><td>Quinbrook, 28 July 2026<\/td><td>Stage 1+2: 520MW \/ 1,858MWh<\/td><td>Operating status, financing, offtake<\/td><\/tr><tr><td>Supernode project page<\/td><td>760MW \/ 3,096MWh<\/td><td>Older snapshot; keep the page date and do not mix totals<\/td><\/tr><\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3b2fadbf auto-p elementor-widget elementor-widget-heading\" data-id=\"3b2fadbf\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">\u0627\u0644\u0640 <a href=\"https:\/\/supernode.com.au\/project\/metro-dc\/\" target=\"_blank\" rel=\"noopener\">Supernode project page<\/a> also says the site ties to the regional transmission grid at <strong>275kV<\/strong>. Its line that 80% of Queensland electricity flows through South Pine each day stays attributed to that site.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-964bb448 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"964bb448\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Start with the delivery obligation, then look at battery nameplates<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-98ff2e28 auto-p elementor-widget elementor-widget-heading\" data-id=\"98ff2e28\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Contract or grid-connection obligations come first. Container count comes later.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-93dba8fd auto-p elementor-widget elementor-widget-heading\" data-id=\"93dba8fd\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">For a four-hour duty at 260MW:<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1057a964 auto-p elementor-widget elementor-widget-heading\" data-id=\"1057a964\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\"><strong>Required delivered energy = 260MW \u00d7 4h = 1,040MWh<\/strong><\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-77931389 auto-p elementor-widget elementor-widget-heading\" data-id=\"77931389\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Stage 3 publishes 1,216MWh. The gap is 176MWh, about 16.9% above a pure four-hour multiply.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1f922284 auto-p elementor-widget elementor-widget-heading\" data-id=\"1f922284\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">That margin might cover usable SOC, conversion losses, auxiliaries, degradation allowance, reserve policy or something else the project locked in. Public notes do not split the 176MWh. You need the technical schedule, offtake and approved design for that split.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-dbb1e9dc auto-p elementor-widget elementor-widget-heading\" data-id=\"dbb1e9dc\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">So the 4.68-hour nameplate ratio is not a 4.68-hour guaranteed export duration.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d69f9f4d auto-h2 elementor-widget elementor-widget-heading\" data-id=\"d69f9f4d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Four energy boundaries stay separate<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-351cbb53 auto-table elementor-widget elementor-widget-text-editor\" data-id=\"351cbb53\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"cea-table-wrap\"><table><thead><tr><th>\u0627\u0644\u062d\u062f\u0648\u062f<\/th><th>Question<\/th><th>Evidence<\/th><\/tr><\/thead><tbody><tr><td>Installed DC nameplate<\/td><td>How much battery energy is physically installed?<\/td><td>Container datasheets, rack schedules, as-built serials<\/td><\/tr><tr><td>Usable DC energy<\/td><td>How much sits inside the allowed SOC window?<\/td><td>BMS limits, temperature limits, SOH basis, warranty schedule<\/td><\/tr><tr><td>AC energy at the PCS<\/td><td>What remains after battery and conversion losses?<\/td><td>Defined efficiency test, PCS loss data, auxiliary treatment<\/td><\/tr><tr><td>Delivered energy at the POI<\/td><td>What hits the contractual meter?<\/td><td>Revenue meters, transformer losses, collection losses, test records<\/td><\/tr><\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5b3462ce auto-p elementor-widget elementor-widget-heading\" data-id=\"5b3462ce\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">A workable screen:<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ffece69c auto-p elementor-widget elementor-widget-heading\" data-id=\"ffece69c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\"><strong>Delivered POI energy = installed DC energy \u00d7 usable SOC fraction \u00d7 retained-capacity factor \u00d7 discharge-path efficiency \u2212 interval auxiliaries<\/strong><\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c47a149a auto-p elementor-widget elementor-widget-heading\" data-id=\"c47a149a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Each term needs its own boundary. One product-page efficiency number will not close the sum.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0702106c auto-image elementor-widget elementor-widget-image\" data-id=\"0702106c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/Four-Energy-Boundaries-for-Four-Hour-BESS.png\" class=\"attachment-1536x1536 size-1536x1536 wp-image-4987\" alt=\"Four BESS energy boundaries from installed DC and usable DC through PCS AC to POI delivery\" srcset=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/Four-Energy-Boundaries-for-Four-Hour-BESS.png 1024w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/Four-Energy-Boundaries-for-Four-Hour-BESS-300x225.png 300w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/Four-Energy-Boundaries-for-Four-Hour-BESS-768x576.png 768w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/Four-Energy-Boundaries-for-Four-Hour-BESS-16x12.png 16w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/Four-Energy-Boundaries-for-Four-Hour-BESS-600x450.png 600w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7d6f2956 auto-p elementor-widget elementor-widget-heading\" data-id=\"7d6f2956\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Where the package ends: <strong><a href=\"https:\/\/www.solidess.com\/ar\/%d8%ad%d8%af%d9%88%d8%af-%d8%b4%d8%a8%d9%83%d8%a9-%d9%86%d8%b8%d8%a7%d9%85-%d8%aa%d8%ae%d8%b2%d9%8a%d9%86-%d8%a7%d9%84%d8%b7%d8%a7%d9%82%d8%a9-%d8%a7%d9%84%d8%a8%d8%b7%d8%a7%d8%b1%d9%8a-%d8%a7%d9%84\/\" target=\"_blank\" style=\"color:#61ce70\">container, transformer and grid-connection responsibilities<\/a><\/strong>.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-95a3aff8 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"95a3aff8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Why one 5000INTL ratio produces two container counts<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-76591d5e auto-p elementor-widget elementor-widget-heading\" data-id=\"76591d5e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">MegSolid\u2019s 5000INTL page publishes this standard setup:<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-06080ff9 auto-table elementor-widget elementor-widget-text-editor\" data-id=\"06080ff9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"cea-table-wrap\"><table><thead><tr><th>\u0627\u0644\u0645\u0639\u0644\u0645\u0629 \u0627\u0644\u0645\u0646\u0634\u0648\u0631\u0629<\/th><th>\u0627\u0644\u0642\u064a\u0645\u0629 5000INTL<\/th><\/tr><\/thead><tbody><tr><td>\u0627\u0644\u0637\u0627\u0642\u0629 \u0627\u0644\u0645\u0642\u062f\u0631\u0629<\/td><td>5,015.9kWh<\/td><\/tr><tr><td>\u0627\u0644\u0642\u062f\u0631\u0629 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0627\u0644\u0645\u0642\u0646\u0646\u0629 \u0627\u0644\u062a\u064a \u062a\u0639\u0645\u0644 \u0628\u0627\u0644\u062a\u064a\u0627\u0631 \u0627\u0644\u0645\u062a\u0631\u062f\u062f<\/td><td>450kW \u00d7 6 = 2.7MW<\/td><\/tr><tr><td>Nameplate duration<\/td><td>About 1.86 hours<\/td><\/tr><tr><td>Nominal DC voltage<\/td><td>1,331.2Vdc<\/td><\/tr><tr><td>Operating DC range<\/td><td>1,123.2\u20131,497.6Vdc<\/td><\/tr><tr><td>\u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a \u0627\u0644\u0645\u062a\u0631\u062f\u062f \u0627\u0644\u0645\u0642\u0646\u0646<\/td><td>690Vac<\/td><\/tr><tr><td>\u062a\u0628\u0631\u064a\u062f<\/td><td>\u0646\u0638\u0627\u0645 \u0627\u0644\u062a\u0628\u0631\u064a\u062f \u0627\u0644\u0633\u0627\u0626\u0644 \u0627\u0644\u0630\u0643\u064a<\/td><\/tr><tr><td>Protection<\/td><td>\u0622\u064a \u0628\u064a \u0665\u0665<\/td><\/tr><tr><td>\u062f\u0631\u062c\u0629 \u062d\u0631\u0627\u0631\u0629 \u0627\u0644\u062a\u0634\u063a\u064a\u0644<\/td><td>\u221230\u00b0C to 55\u00b0C<\/td><\/tr><tr><td>\u0627\u0644\u0627\u062a\u0635\u0627\u0644\u0627\u062a<\/td><td>\u0625\u064a\u062b\u0631\u0646\u062a \u0648 RS485<\/td><\/tr><tr><td>\u0623\u0642\u0635\u0649 \u0643\u0641\u0627\u0621\u0629<\/td><td>87.5% (confirm measurement boundary)<\/td><\/tr><\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1733e32e elementor-tablet-align-center elementor-align-center auto-cta elementor-widget elementor-widget-button\" data-id=\"1733e32e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"#elementor-action%3Aaction%3Dpopup%3Aopen%26settings%3DeyJpZCI6Ijk0OCIsInRvZ2dsZSI6ZmFsc2V9\" target=\"_blank\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Send MegSolid your MW, delivered MWh, POI voltage and contract-year requirement for an initial sizing check.<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a5c35e0e auto-p elementor-widget elementor-widget-heading\" data-id=\"a5c35e0e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Full sheet: <strong><a href=\"https:\/\/www.solidess.com\/ar\/product\/%d9%86%d8%b8%d8%a7%d9%85-%d8%aa%d8%ae%d8%b2%d9%8a%d9%86-%d8%a7%d9%84%d8%b7%d8%a7%d9%82%d8%a9-%d8%a7%d9%84%d8%ad%d8%a7%d9%88%d9%8a-%d9%85%d9%8a%d8%ba%d8%a7%d8%b3%d9%88%d9%84%d9%8a%d8%af-5000intl\/\" target=\"_blank\" style=\"color:#61ce70\">MegSolid 5000INTL product page<\/a><\/strong>.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-19b9dae3 auto-h3 elementor-widget elementor-widget-heading\" data-id=\"19b9dae3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Power-first calculation<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4fb6298f auto-p elementor-widget elementor-widget-heading\" data-id=\"4fb6298f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\"><strong>260MW \u00f7 2.7MW per unit = 96.3 units<\/strong><\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e33f7a29 auto-p elementor-widget elementor-widget-heading\" data-id=\"e33f7a29\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Round up to <strong>97<\/strong> standard units. Combined nameplate energy:<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6c6c35b3 auto-p elementor-widget elementor-widget-heading\" data-id=\"6c6c35b3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\"><strong>97 \u00d7 5.0159MWh = 486.5MWh<\/strong><\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4c25f0d4 auto-p elementor-widget elementor-widget-heading\" data-id=\"4c25f0d4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">At a 260MW plant limit that is about 1.87 hours before usable-energy cuts. Power is covered at nameplate level. The four-hour energy duty is not.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-da8d0037 auto-h3 elementor-widget elementor-widget-heading\" data-id=\"da8d0037\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Energy-first calculation<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-bc76c2f0 auto-p elementor-widget elementor-widget-heading\" data-id=\"bc76c2f0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\"><strong>1,216MWh \u00f7 5.0159MWh per unit = 242.4 units<\/strong><\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9cd8c97b auto-p elementor-widget elementor-widget-heading\" data-id=\"9cd8c97b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Round up to <strong>243<\/strong> standard units. Listed aggregate AC power:<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3f702f30 auto-p elementor-widget elementor-widget-heading\" data-id=\"3f702f30\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\"><strong>243 \u00d7 2.7MW = 656.1MW<\/strong><\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-58a27c1b auto-p elementor-widget elementor-widget-heading\" data-id=\"58a27c1b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Installed energy reaches published project scale. Catalogue AC capacity sits more than 2.5\u00d7 the 260MW rating.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-85bad7b8 auto-h3 elementor-widget elementor-widget-heading\" data-id=\"85bad7b8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">What 243 energy blocks imply<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e47377a3 auto-p elementor-widget elementor-widget-heading\" data-id=\"e47377a3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">If 243 equal energy blocks share a 260MW plant limit, each block carries only about <strong>1.07MW<\/strong> of project-level AC on average.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-413b86a3 auto-p elementor-widget elementor-widget-heading\" data-id=\"413b86a3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">That does not rewrite the listed 2.7MW rating of a standard 5000INTL. It points to another layout: custom PCS allocation, DC-coupled energy blocks, centralised conversion, or another controlled topology.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3da06fc3 auto-p elementor-widget elementor-widget-heading\" data-id=\"3da06fc3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">MegSolid still has to confirm whether that layout is offered for the job. The standard integrated 5000INTL stays <strong>2.7MW \/ 5.0159MWh<\/strong> until a controlled proposal says otherwise.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-248553f0 auto-p elementor-widget elementor-widget-heading\" data-id=\"248553f0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Same power-vs-energy split shows up on other large delivery jobs: <strong><a href=\"https:\/\/www.solidess.com\/ar\/dispatchable-solar-bess-south-africa-hydra-project\/\" target=\"_blank\" style=\"color:#61ce70\">contracted power and energy drive different container and PCS counts<\/a><\/strong>.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c96420b3 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"c96420b3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">The final container count needs six adjustments<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9fdfdd04 auto-p elementor-widget elementor-widget-heading\" data-id=\"9fdfdd04\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\"><strong>Usable SOC window<\/strong> The BMS may reserve both ends of SOC. The contract should say whether 1,216MWh is gross installed, usable DC or another declared boundary.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c7da0f90 auto-p elementor-widget elementor-widget-heading\" data-id=\"c7da0f90\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\"><strong>End-of-life capacity<\/strong> Four hours at beginning of life, at a later warranty year, or through the whole contract \u2014 each choice changes initial count and augmentation.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-603fdf48 auto-p elementor-widget elementor-widget-heading\" data-id=\"603fdf48\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\"><strong>Conversion and collection losses<\/strong> Battery, PCS, transformers, MV collection and the 275kV tie sit on different sides of the sum. Allocation follows the delivery point.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-443e19c9 auto-p elementor-widget elementor-widget-heading\" data-id=\"443e19c9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\"><strong>\u0627\u0644\u0627\u0633\u062a\u0647\u0644\u0627\u0643 \u0627\u0644\u0645\u0633\u0627\u0639\u062f<\/strong> Liquid cooling, pumps, controls, fire systems, heaters and substation loads all draw energy. Settlement and test methods must say whether auxiliaries sit inside or outside the delivery boundary.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-17ccbb5b auto-p elementor-widget elementor-widget-heading\" data-id=\"17ccbb5b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\"><strong>Availability and maintenance isolation<\/strong> N-1 design, planned outages and forced outages can add blocks beyond a pure energy count. The plant controller needs a defined way to report available MW when one block is offline.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-21fbba14 auto-p elementor-widget elementor-widget-heading\" data-id=\"21fbba14\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\"><strong>Reactive-power duty<\/strong> 260MW of active power is not the full MVA story. GPS studies can demand reactive current in voltage events, which eats PCS headroom and can resize transformers.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f666ad15 auto-p elementor-widget elementor-widget-heading\" data-id=\"f666ad15\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">PCS boundary questions: <strong><a href=\"https:\/\/www.solidess.com\/ar\/pcs-inverter-engineering\/\" target=\"_blank\" style=\"color:#61ce70\">MegSolid PCS engineering framework<\/a><\/strong>. Project grid-forming and reactive-current capability still need approved models and settings.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-dd308a9c auto-h2 elementor-widget elementor-widget-heading\" data-id=\"dd308a9c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">GPS acceptance changes the evidence package<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1b4b14d3 auto-p elementor-widget elementor-widget-heading\" data-id=\"1b4b14d3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">GPS acceptance locks the technical performance standards for connection to the NEM. It does not turn a catalogue rating into an approved plant design.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-acd648fd auto-p elementor-widget elementor-widget-heading\" data-id=\"acd648fd\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\"><a href=\"https:\/\/www.aemo.com.au\/energy-systems\/electricity\/national-electricity-market-nem\/participate-in-the-market\/network-connections\/modelling-requirements\" target=\"_blank\" rel=\"noopener\">AEMO modelling requirements<\/a> ask connection applicants for a model package that matches the structure and performance of the generating plant, under the Power System Model Guidelines and data sheets.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6970ff12 auto-p elementor-widget elementor-widget-heading\" data-id=\"6970ff12\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">For a multi-container BESS the chain usually includes:<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-fe45ef49 elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"fe45ef49\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">RMS and EMT model packages with version control<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">PCS control modes and current-limiting behaviour<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">PPC hierarchy and plant-level active\/reactive limits<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Transformer and collector-network representation<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Protection settings and disturbance response<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Model validation against factory and site tests<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Fallback after communications loss<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">As-built parameter reconciliation<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-71e32c59 auto-p elementor-widget elementor-widget-heading\" data-id=\"71e32c59\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\"><a href=\"https:\/\/www.aemo.com.au\/initiatives\/major-programs\/engineering-roadmap\/engineering-roadmap-execution-reports\" target=\"_blank\" rel=\"noopener\">AEMO\u2019s grid-forming inverter test framework<\/a> checks core capabilities in simulation. It is a test framework, not a universal product certificate.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e1d776ee auto-p elementor-widget elementor-widget-heading\" data-id=\"e1d776ee\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Signal ownership: <strong><a href=\"https:\/\/www.solidess.com\/ar\/%d9%82%d8%a7%d8%a6%d9%85%d8%a9-%d9%86%d9%82%d8%a7%d8%b7-%d8%b3%d9%83%d8%a7%d8%af%d8%a7-%d9%84%d9%86%d8%b8%d8%a7%d9%85-%d8%aa%d8%ae%d8%b2%d9%8a%d9%86-%d8%a7%d9%84%d8%b7%d8%a7%d9%82%d8%a9-%d8%a8%d8%a7\/\" target=\"_blank\" style=\"color:#61ce70\">\u0647\u064a\u0643\u0644 \u0642\u0627\u0626\u0645\u0629 \u0646\u0642\u0627\u0637 \u0646\u0638\u0627\u0645 BESS SCADA<\/a><\/strong>. Command hierarchy: <strong><a href=\"https:\/\/www.solidess.com\/ar\/%d8%a8%d9%86%d9%8a%d8%a9-%d8%a7%d8%aa%d8%b5%d8%a7%d9%84%d8%a7%d8%aa-%d9%86%d8%b8%d8%a7%d9%85-%d8%a5%d8%af%d8%a7%d8%b1%d8%a9-%d8%a7%d9%84%d8%a8%d8%b7%d8%a7%d8%b1%d9%8a%d8%a9-bms-%d9%88%d9%86%d8%b8\/\" target=\"_blank\" style=\"color:#61ce70\">BMS, EMS and PPC command hierarchy<\/a><\/strong>.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-fd6e7af5 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"fd6e7af5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Supernode\u2019s supplier structure versus a MegSolid route<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5042570e auto-p elementor-widget elementor-widget-heading\" data-id=\"5042570e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Supernode Stage 3 pairs CATL battery systems with GE Vernova PCS, controls, integration and grid-connection support. Public material also covers long-term service and offtake.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b3bd784a auto-p elementor-widget elementor-widget-heading\" data-id=\"b3bd784a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">MegSolid\u2019s listed 5000INTL is a different starting point: <strong>5.0159MWh<\/strong> rated energy with <strong>2.7MW<\/strong> rated AC power in one published configuration.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f8167b46 auto-table elementor-widget elementor-widget-text-editor\" data-id=\"f8167b46\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"cea-table-wrap\"><table><thead><tr><th>Procurement factor<\/th><th>Supernode Stage 3 public structure<\/th><th>MegSolid 5000INTL starting point<\/th><\/tr><\/thead><tbody><tr><td>Project scale<\/td><td>260MW \/ 1,216MWh<\/td><td>2.7MW \/ 5.0159MWh per listed unit<\/td><\/tr><tr><td>Battery supplier<\/td><td>CATL TENER S<\/td><td>MegSolid SHS180-314 battery type<\/td><\/tr><tr><td>PCS and integration<\/td><td>GE Vernova project scope<\/td><td>AC rating in the standard product; project scope still needs confirmation<\/td><\/tr><tr><td>Grid-forming statement<\/td><td>GE Vernova\u2019s first Australian grid-forming BESS project<\/td><td>No project-specific Australian GPS or grid-forming approval published for 5000INTL<\/td><\/tr><tr><td>Service evidence<\/td><td>CATL lifecycle support under LTSA<\/td><td>Warranty, spares, monitoring and service scope negotiated per job<\/td><\/tr><tr><td>Best procurement use<\/td><td>Bankable multi-vendor mega-project with accepted GPS<\/td><td>Direct OEM evaluation, phased utility work, custom architecture studies<\/td><\/tr><\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-187363b1 auto-p elementor-widget elementor-widget-heading\" data-id=\"187363b1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">A developer chasing a direct substitute for the contracted Supernode consortium needs equivalent project-level models, controls, service commitments and Australian integration experience.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3d0d52a1 auto-p elementor-widget elementor-widget-heading\" data-id=\"3d0d52a1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">A developer evaluating MegSolid gets a clear 5MWh-class reference block, factory engineering access and room to set the architecture before the EPC price hardens.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-dea492c7 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"dea492c7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Where the 5000INTL can create procurement value<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e1ce6046 auto-p elementor-widget elementor-widget-heading\" data-id=\"e1ce6046\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\"><strong>Transparent nameplate ratio<\/strong> 2.7MW \/ 5.0159MWh shows the duration mismatch at once. Buyers can challenge PCS oversizing before a large container count lands in the commercial proposal.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3c85aa38 auto-p elementor-widget elementor-widget-heading\" data-id=\"3c85aa38\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\"><strong>High-voltage DC architecture<\/strong> 1,331.2Vdc nominal can mean lower DC current for a given power than a lower-voltage alternative, if the PCS, protection and cable system match. Prove it with project loss and thermal calcs.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-15e0fc22 auto-p elementor-widget elementor-widget-heading\" data-id=\"15e0fc22\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\"><strong>Outdoor utility-scale packaging<\/strong> IP55, smart liquid cooling and \u221230\u00b0C to 55\u00b0C give a defined environmental starting line. Site ambient, solar gain, humidity, flood, fire access and noise remain project inputs.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-56677304 auto-p elementor-widget elementor-widget-heading\" data-id=\"56677304\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\"><strong>Factory evidence before shipment<\/strong> Require serial-level configuration records, communication maps, cooling alarms, protection tests and raw FAT data before release. <strong><a href=\"https:\/\/www.solidess.com\/ar\/%d8%af%d9%84%d9%8a%d9%84-%d8%a7%d8%ae%d8%aa%d8%a8%d8%a7%d8%b1-%d8%a7%d9%84%d9%82%d8%a8%d9%88%d9%84-%d9%81%d9%8a-%d8%a7%d9%84%d9%85%d8%b5%d9%86%d8%b9-%d9%84%d8%b4%d8%b1%d9%83%d8%a9-%d8%a8%d9%8a\/\" target=\"_blank\" style=\"color:#61ce70\">BESS FAT witness structure<\/a><\/strong> helps assign ownership.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9db7f32f auto-p elementor-widget elementor-widget-heading\" data-id=\"9db7f32f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\"><strong>Product-scale engineering detail<\/strong> <strong><a href=\"https:\/\/www.solidess.com\/ar\/engineering-the-5mwh-bess\/\" target=\"_blank\" style=\"color:#61ce70\">5000INTL engineering analysis<\/a><\/strong> covers DC voltage, cooling and dense container layout. That supports pre-FEED work. GPS and POI performance stay separate approvals.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9daf6f58 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"9daf6f58\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Minimum sizing schedule for a four-hour Australian BESS<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-47d25df3 auto-table elementor-widget elementor-widget-text-editor\" data-id=\"47d25df3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"cea-table-wrap\"><table><thead><tr><th>Field<\/th><th>\u064a\u062c\u0628 \u0639\u0644\u0649 \u0627\u0644\u0645\u0634\u062a\u0631\u064a \u0623\u0646 \u064a\u0630\u0643\u0631<\/th><th>\u064a\u062c\u0628 \u0639\u0644\u0649 \u0627\u0644\u0645\u0648\u0631\u062f \u0625\u0639\u0627\u062f\u0629<\/th><\/tr><\/thead><tbody><tr><td>POI active power<\/td><td>Export and charge MW, duration, ramp basis<\/td><td>Guaranteed plant MW and limiting equipment<\/td><\/tr><tr><td>Delivery duration<\/td><td>Beginning-of-life or end-of-life requirement<\/td><td>Delivered MWh at the named meter<\/td><\/tr><tr><td>Energy boundary<\/td><td>Gross DC, usable DC, PCS output or POI<\/td><td>Loss map and auxiliary treatment<\/td><\/tr><tr><td>SOC limits<\/td><td>Normal dispatch and emergency reserve<\/td><td>BMS hard limits and EMS operating limits<\/td><\/tr><tr><td>Degradation basis<\/td><td>Contract year, temperature, cycle profile<\/td><td>Retention curve and augmentation schedule<\/td><\/tr><tr><td>\u0627\u0644\u062a\u0648\u0627\u0641\u0631<\/td><td>Planned and forced-outage assumptions<\/td><td>Installed redundancy and available-MW logic<\/td><\/tr><tr><td>Reactive duty<\/td><td>GPS operating points<\/td><td>PCS MVA headroom and P-Q capability<\/td><\/tr><tr><td>Connection voltage<\/td><td>Collector and POI voltages<\/td><td>Transformer, switchgear, protection boundary<\/td><\/tr><tr><td>\u0639\u0646\u0627\u0635\u0631 \u0627\u0644\u062a\u062d\u0643\u0645<\/td><td>AEMO\/NSP, PPC and EMS hierarchy<\/td><td>Point list, command ownership, fallback state<\/td><\/tr><tr><td>Acceptance<\/td><td>Model, FAT, SAT, performance tests<\/td><td>Instruments, raw data, tolerances, signatures<\/td><\/tr><\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3eddfc81 auto-p elementor-widget elementor-widget-heading\" data-id=\"3eddfc81\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Security and remote access belong in the same controls schedule. Starting point: <strong><a href=\"https:\/\/www.solidess.com\/ar\/securing-the-grid\/\" target=\"_blank\" style=\"color:#61ce70\">BESS cybersecurity engineering framework<\/a><\/strong>.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-12c1bc5f auto-h2 elementor-widget elementor-widget-heading\" data-id=\"12c1bc5f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">What to send MegSolid for a preliminary architecture check<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-337d3f16 auto-p elementor-widget elementor-widget-heading\" data-id=\"337d3f16\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Four controlled inputs:<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ba67837e elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"ba67837e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">required MW at the POI<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">required delivered MWh and duration basis<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">beginning-of-life or end-of-life obligation<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">proposed PCS, transformer and connection boundary<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e7c6b55f auto-p elementor-widget elementor-widget-heading\" data-id=\"e7c6b55f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">MegSolid can return a preliminary energy-block count, AC conversion range and a list of open assumptions \u2014 where the standard 5000INTL ratio fits and where custom engineering is required.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f89c2cbb auto-h2 elementor-widget elementor-widget-heading\" data-id=\"f89c2cbb\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Procurement decision<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ab3c52fe auto-p elementor-widget elementor-widget-heading\" data-id=\"ab3c52fe\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Supernode Stage 3 shows a four-hour BESS is defined by its delivery boundary, not by a container label. The public 260MW \/ 1,216MWh figures carry 176MWh more nameplate energy than a pure four-hour multiply; how that margin is spent stays inside project documents.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9767cf2e auto-p elementor-widget elementor-widget-heading\" data-id=\"9767cf2e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">On the standard 5000INTL, power-first selection leaves too little energy for this profile. Energy-first selection buys a large excess of listed AC capacity. A credible MegSolid proposal needs a controlled DC\/AC architecture, an explicit usable-energy equation and a project-specific GPS evidence plan.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c94b5a4c elementor-tablet-align-center elementor-align-center auto-cta elementor-widget elementor-widget-button\" data-id=\"c94b5a4c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"#elementor-action%3Aaction%3Dpopup%3Aopen%26settings%3DeyJpZCI6Ijk0OCIsInRvZ2dsZSI6ZmFsc2V9\" target=\"_blank\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Ask MegSolid to compare the standard 2.7MW \/ 5.0159MWh block with your four-hour POI obligation before you request a firm EPC price.<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-aee04d37 auto-faq e-flex e-con-boxed e-con e-child\" data-id=\"aee04d37\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-8cdd2d00 elementor-widget elementor-widget-heading\" data-id=\"8cdd2d00\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">\u0627\u0644\u0623\u0633\u0626\u0644\u0629 \u0627\u0644\u0634\u0627\u0626\u0639\u0629<\/h2>\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-92aa8216 e-con-full e-flex e-con e-child\" data-id=\"92aa8216\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-e9cb0986 elementor-widget elementor-widget-n-accordion\" data-id=\"e9cb0986\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;default_state&quot;:&quot;all_collapsed&quot;,&quot;max_items_expended&quot;:&quot;one&quot;,&quot;n_accordion_animation_duration&quot;:{&quot;unit&quot;:&quot;ms&quot;,&quot;size&quot;:400,&quot;sizes&quot;:[]}}\" data-widget_type=\"nested-accordion.default\">\n\t\t\t\t\t\t\t<div class=\"e-n-accordion\" aria-label=\"\u0627\u0644\u0623\u0643\u0648\u0631\u062f\u064a\u0648\u0646. \u0627\u0641\u062a\u062d \u0627\u0644\u0631\u0648\u0627\u0628\u0637 \u0628\u0627\u0633\u062a\u062e\u062f\u0627\u0645 \u0645\u0641\u062a\u0627\u062d \u0627\u0644\u0625\u062f\u062e\u0627\u0644 (Enter) \u0623\u0648 \u0627\u0644\u0645\u0633\u0627\u0641\u0629 (Space)\u060c \u0648\u0623\u063a\u0644\u0642 \u0628\u0627\u0633\u062a\u062e\u062f\u0627\u0645 \u0645\u0641\u062a\u0627\u062d \u0627\u0644\u0647\u0631\u0648\u0628 (Escape)\u060c \u0648\u062a\u0648\u0643\u0644 \u0639\u0628\u0631 \u0645\u0641\u0627\u062a\u064a\u062d \u0627\u0644\u0623\u0633\u0647\u0645\">\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-3920\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"1\" tabindex=\"0\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-3920\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> What is the published rating of Supernode Stage 3? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3920\" class=\"elementor-element elementor-element-fe6171e0 e-con-full e-flex e-con e-child\" data-id=\"fe6171e0\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3920\" class=\"elementor-element elementor-element-df47111c e-con-full e-flex e-con e-child\" data-id=\"df47111c\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a470827d elementor-widget elementor-widget-heading\" data-id=\"a470827d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">GE Vernova publishes Stage 3 at 260MW \/ 1,216MWh and describes it as four-hour storage. The ratio of the two nameplate figures is about 4.68 hours.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-3921\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"2\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-3921\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Why is 1,216MWh higher than 260MW \u00d7 four hours? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3921\" class=\"elementor-element elementor-element-1cafe7b3 e-con-full e-flex e-con e-child\" data-id=\"1cafe7b3\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3921\" class=\"elementor-element elementor-element-2d79905c e-con-full e-flex e-con e-child\" data-id=\"2d79905c\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-3bf6ec33 elementor-widget elementor-widget-heading\" data-id=\"3bf6ec33\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Exact four-hour delivery at 260MW equals 1,040MWh. The extra 176MWh may cover usable SOC, losses, degradation, reserve or another design need. Public releases do not allocate that margin.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-3922\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"3\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-3922\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> How many MegSolid 5000INTL units equal 260MW? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3922\" class=\"elementor-element elementor-element-56d43529 e-con-full e-flex e-con e-child\" data-id=\"56d43529\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3922\" class=\"elementor-element elementor-element-5bfaccd4 e-con-full e-flex e-con e-child\" data-id=\"5bfaccd4\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-f1dd1373 elementor-widget elementor-widget-heading\" data-id=\"f1dd1373\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">260MW \u00f7 2.7MW = 96.3, so a nameplate power check rounds up to 97 units. Those units hold only about 486.5MWh of combined rated energy.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-3923\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"4\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-3923\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> How many 5000INTL units equal 1,216MWh? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3923\" class=\"elementor-element elementor-element-f6c870bb e-con-full e-flex e-con e-child\" data-id=\"f6c870bb\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3923\" class=\"elementor-element elementor-element-991130c8 e-con-full e-flex e-con e-child\" data-id=\"991130c8\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-b1df7d57 elementor-widget elementor-widget-heading\" data-id=\"b1df7d57\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">1,216MWh \u00f7 5.0159MWh = 242.4, so a nameplate energy check rounds up to 243 units. Listed aggregate AC rating would be 656.1MW.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-3924\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"5\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-3924\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Can 243 standard 5000INTL units be limited to 260MW? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3924\" class=\"elementor-element elementor-element-eb3b3b26 e-con-full e-flex e-con e-child\" data-id=\"eb3b3b26\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3924\" class=\"elementor-element elementor-element-bdc207fd e-con-full e-flex e-con e-child\" data-id=\"bdc207fd\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-209f4748 elementor-widget elementor-widget-heading\" data-id=\"209f4748\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">A plant controller can impose an export limit, but the project would still buy 656.1MW of listed AC conversion capacity. Commercial design should weigh a customised PCS allocation or another DC\/AC topology.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-3925\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"6\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-3925\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Is the 5000INTL a four-hour BESS block? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3925\" class=\"elementor-element elementor-element-1e4ebdad e-con-full e-flex e-con e-child\" data-id=\"1e4ebdad\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3925\" class=\"elementor-element elementor-element-9920734c e-con-full e-flex e-con e-child\" data-id=\"9920734c\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-eae014d2 elementor-widget elementor-widget-heading\" data-id=\"eae014d2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Published 5.0159MWh and 2.7MW give a nameplate duration of about 1.86 hours. Four-hour projects need a different energy-to-power ratio.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-3926\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"7\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-3926\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Does 87.5% maximum efficiency equal project round-trip efficiency? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3926\" class=\"elementor-element elementor-element-83a8f797 e-con-full e-flex e-con e-child\" data-id=\"83a8f797\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3926\" class=\"elementor-element elementor-element-6232f704 e-con-full e-flex e-con e-child\" data-id=\"6232f704\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-479b26a9 elementor-widget elementor-widget-heading\" data-id=\"479b26a9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">The product page labels 87.5% as maximum efficiency. POI round-trip efficiency needs a defined test boundary covering SOC, power, temperature, auxiliaries, transformers and collection losses.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-3927\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"8\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-3927\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Which energy value should appear in a four-hour BESS contract? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3927\" class=\"elementor-element elementor-element-ef37f7ab e-con-full e-flex e-con e-child\" data-id=\"ef37f7ab\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3927\" class=\"elementor-element elementor-element-55ed6f46 e-con-full e-flex e-con e-child\" data-id=\"55ed6f46\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-27175b88 elementor-widget elementor-widget-heading\" data-id=\"27175b88\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">State delivered MWh at a named meter and the applicable contract year. Gross DC nameplate can sit as a separate design parameter.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-3928\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"9\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-3928\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Why does end-of-life duration change the initial container count? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3928\" class=\"elementor-element elementor-element-ae0188fe e-con-full e-flex e-con e-child\" data-id=\"ae0188fe\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3928\" class=\"elementor-element elementor-element-0feb2090 e-con-full e-flex e-con e-child\" data-id=\"0feb2090\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-8c57f33f elementor-widget elementor-widget-heading\" data-id=\"8c57f33f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Capacity falls with age and use. A four-hour obligation held later in the contract may need initial oversizing, augmentation or both.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-3929\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"10\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-3929\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> What does GPS acceptance mean for a BESS? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3929\" class=\"elementor-element elementor-element-bc4f5b8d e-con-full e-flex e-con e-child\" data-id=\"bc4f5b8d\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3929\" class=\"elementor-element elementor-element-b55d51c3 e-con-full e-flex e-con e-child\" data-id=\"b55d51c3\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-1af52b3e elementor-widget elementor-widget-heading\" data-id=\"1af52b3e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">It sets the agreed technical performance standards for connection to the NEM. It rests on project models, settings and studies \u2014 not one equipment datasheet.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-39210\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"11\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-39210\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Has MegSolid 5000INTL received Supernode-equivalent GPS acceptance? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-39210\" class=\"elementor-element elementor-element-dbfc444c e-con-full e-flex e-con e-child\" data-id=\"dbfc444c\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-39210\" class=\"elementor-element elementor-element-78317dad e-con-full e-flex e-con e-child\" data-id=\"78317dad\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-62c5f8e4 elementor-widget elementor-widget-heading\" data-id=\"62c5f8e4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">No project-specific Australian GPS acceptance has been published for the 5000INTL. Any Australian utility project needs its own connection process, model package and approved plant settings.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-39211\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"12\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-39211\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Is Supernode Stage 3 Australia\u2019s first grid-forming BESS? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-39211\" class=\"elementor-element elementor-element-1820a9f1 e-con-full e-flex e-con e-child\" data-id=\"1820a9f1\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-39211\" class=\"elementor-element elementor-element-f43f5b01 e-con-full e-flex e-con e-child\" data-id=\"f43f5b01\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-cf85b6c7 elementor-widget elementor-widget-heading\" data-id=\"cf85b6c7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">GE Vernova calls it the company\u2019s first grid-forming BESS project in Australia. Do not stretch that into \u201cfirst grid-forming battery in the country.\u201d<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-39212\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"13\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-39212\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> What voltage connects the Supernode site to the transmission grid? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-39212\" class=\"elementor-element elementor-element-9d007a75 e-con-full e-flex e-con e-child\" data-id=\"9d007a75\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-39212\" class=\"elementor-element elementor-element-67de5c42 e-con-full e-flex e-con e-child\" data-id=\"67de5c42\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-9656e133 elementor-widget elementor-widget-heading\" data-id=\"9656e133\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">The Supernode project page states a 275kV connection to the regional transmission grid. Collector voltages and internal transformers are separate design details.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-39213\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"14\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-39213\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Why are reactive-power requirements relevant to container count? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-39213\" class=\"elementor-element elementor-element-aa2f361e e-con-full e-flex e-con e-child\" data-id=\"aa2f361e\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-39213\" class=\"elementor-element elementor-element-6659b724 e-con-full e-flex e-con e-child\" data-id=\"6659b724\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-87d17421 elementor-widget elementor-widget-heading\" data-id=\"87d17421\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Reactive current uses PCS and transformer capacity. GPS operating points can cut active-power headroom under some voltage conditions.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-39214\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"15\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-39214\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> What should FAT verify for a multi-container four-hour BESS? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-39214\" class=\"elementor-element elementor-element-f294c764 e-con-full e-flex e-con e-child\" data-id=\"f294c764\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-39214\" class=\"elementor-element elementor-element-93c5e80f e-con-full e-flex e-con e-child\" data-id=\"93c5e80f\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-37fe0d64 elementor-widget elementor-widget-heading\" data-id=\"37fe0d64\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Container ratings, controls, communications, protection, alarms, cooling behaviour, raw-data capture and model parameters. Site tests then validate the full plant and POI boundary.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-39215\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"16\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-39215\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> What information does MegSolid need for a preliminary four-hour BESS check? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-39215\" class=\"elementor-element elementor-element-54f2b82f e-con-full e-flex e-con e-child\" data-id=\"54f2b82f\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-39215\" class=\"elementor-element elementor-element-32404779 e-con-full e-flex e-con e-child\" data-id=\"32404779\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-31b32af3 elementor-widget elementor-widget-heading\" data-id=\"31b32af3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">POI MW, delivered MWh, duration basis, contract-year requirement, connection voltage and the proposed PCS\/transformer boundary. MegSolid can map preliminary energy-block and AC-conversion ranges from those inputs.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Use Supernode Stage 3 to separate MW, MWh, usable energy and PCS ratio before selecting a four-hour Australian BESS architecture.<\/p>","protected":false},"author":4,"featured_media":4985,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"_joinchat":[],"footnotes":""},"categories":[27,1],"tags":[321,461,460,464,462,463,458,459,131],"class_list":["post-4988","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-news","category-bess","tag-bess-sizing","tag-dc-ac-ratio","tag-four-hour-battery-storage","tag-grid-connection","tag-megsolid-5000intl","tag-nem-battery-storage","tag-queensland-bess","tag-supernode-stage-3","tag-utility-scale-bess"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.solidess.com\/ar\/wp-json\/wp\/v2\/posts\/4988","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.solidess.com\/ar\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.solidess.com\/ar\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.solidess.com\/ar\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/www.solidess.com\/ar\/wp-json\/wp\/v2\/comments?post=4988"}],"version-history":[{"count":4,"href":"https:\/\/www.solidess.com\/ar\/wp-json\/wp\/v2\/posts\/4988\/revisions"}],"predecessor-version":[{"id":5004,"href":"https:\/\/www.solidess.com\/ar\/wp-json\/wp\/v2\/posts\/4988\/revisions\/5004"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.solidess.com\/ar\/wp-json\/wp\/v2\/media\/4985"}],"wp:attachment":[{"href":"https:\/\/www.solidess.com\/ar\/wp-json\/wp\/v2\/media?parent=4988"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.solidess.com\/ar\/wp-json\/wp\/v2\/categories?post=4988"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.solidess.com\/ar\/wp-json\/wp\/v2\/tags?post=4988"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}