{"id":4335,"date":"2026-07-31T11:48:18","date_gmt":"2026-07-31T03:48:18","guid":{"rendered":"https:\/\/www.solidess.com\/?p=4335"},"modified":"2026-10-14T02:49:59","modified_gmt":"2026-10-13T18:49:59","slug":"emportement-thermique-dune-batterie-a-semi-conducteurs-12-points-a-verifier-avant-de-valider-un-bess","status":"publish","type":"post","link":"https:\/\/www.solidess.com\/fr\/solid-state-battery-thermal-runaway-12-checks-before-you-approve-a-bess\/","title":{"rendered":"Emballement thermique des batteries \u00e0 l\u2019\u00e9tat solide : 12 points \u00e0 v\u00e9rifier avant d\u2019approuver un BESS"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"4335\" class=\"elementor elementor-4335\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-bf4793c e-con-full auto-article-root e-flex e-con e-parent\" data-id=\"bf4793c\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-91f29a55 auto-p elementor-widget elementor-widget-heading\" data-id=\"91f29a55\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">L\u2019achat d\u2019un BESS peut \u00eatre bloqu\u00e9 \u00e0 l\u2019\u00e9tape de l\u2019approbation si le fournisseur pr\u00e9sente un slogan de s\u00e9curit\u00e9 au lieu de preuves portant sur l\u2019\u00e9quipement command\u00e9. Tenez compte de <strong>l\u2019emballement thermique des batteries \u00e0 l\u2019\u00e9tat solide<\/strong> dans la d\u00e9cision d\u2019achat. V\u00e9rifiez la cellule, le module, le rack et le syst\u00e8me, puis rattachez au mod\u00e8le la nomenclature (BOM) approuv\u00e9e, les preuves des essais de propagation, la logique de protection et les r\u00e9sultats des essais FAT r\u00e9alis\u00e9s en pr\u00e9sence de t\u00e9moins. MegSolid peut \u00eatre \u00e9valu\u00e9 sur la m\u00eame base. Ces v\u00e9rifications aident votre entreprise EPC \u00e0 combler les lacunes dans les justificatifs avant qu\u2019un acompte n\u2019engage l\u2019achat d\u2019une armoire qui ne pourrait pas \u00eatre r\u00e9ceptionn\u00e9e.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-61af48a9 elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"61af48a9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Distinguer les all\u00e9gations relatives \u00e0 la chimie des preuves issues de l'ensemble du syst\u00e8me.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Rattachez chaque rapport au mod\u00e8le du devis, \u00e0 la version de la nomenclature et \u00e0 la configuration d\u2019installation.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Assistez aux essais FAT et observez les r\u00e9actions du BMS, des dispositifs de d\u00e9tection et d\u2019arr\u00eat et des liaisons de communication.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Reprenez les m\u00eames hypoth\u00e8ses de s\u00e9curit\u00e9 dans la conception du site, les essais de r\u00e9ception sur site (SAT) et la remise de l\u2019installation.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-075565f0 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"075565f0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">La chimie annonc\u00e9e ne suffit pas pour approuver un BESS<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6024f78d auto-p elementor-widget elementor-widget-heading\" data-id=\"6024f78d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Les cellules \u00e0 l\u2019\u00e9tat solide et les cellules hybrides \u00e0 l\u2019\u00e9tat solide sont con\u00e7ues pour r\u00e9duire la d\u00e9pendance \u00e0 l\u2019\u00e9lectrolyte liquide inflammable et am\u00e9liorer la s\u00e9curit\u00e9 intrins\u00e8que. Un BESS commercial contient toujours des connexions \u00e9lectriques, des conducteurs, des composants \u00e9lectroniques de commande, des isolants, des composants de refroidissement et de l\u2019\u00e9nergie stock\u00e9e. La <a href=\"https:\/\/www.solidess.com\/fr\/batterie-solide-hybride-pour-le-stockage-denergie-ci\/\">pr\u00e9sentation technique de MegSolid sur les batteries hybrides \u00e0 l\u2019\u00e9tat solide<\/a> explique les enjeux \u00e0 l\u2019\u00e9chelle de la cellule. Cette liste de contr\u00f4le aide l\u2019acheteur \u00e0 d\u00e9terminer si les justificatifs tra\u00e7ables sur le syst\u00e8me livr\u00e9 suffisent pour l\u2019approuver.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3db80370 auto-p elementor-widget elementor-widget-heading\" data-id=\"3db80370\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\"><strong>D\u00e9cision d'achat :<\/strong> \u00c9valuez la chimie des cellules comme un niveau de protection parmi d\u2019autres. Elle ne remplace pas l\u2019\u00e9tude technique du syst\u00e8me. Le <a href=\"https:\/\/www.energy.gov\/sites\/default\/files\/2024-05\/EED_2827_FIG_SafetyStrategy%20240505v2.pdf\" target=\"_blank\" rel=\"noopener\">plan strat\u00e9gique pour la s\u00e9curit\u00e9 du stockage d\u2019\u00e9nergie du d\u00e9partement de l\u2019\u00c9nergie des \u00c9tats-Unis<\/a> aborde la s\u00e9curit\u00e9 dans la recherche, les codes et normes, la fabrication, la mise en service, l\u2019exploitation et la r\u00e9ponse aux incidents. Une demande de devis d\u00e9fendable devrait couvrir ces m\u00eames aspects tout au long du cycle de vie du projet.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3b701971 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"3b701971\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Emballement thermique des batteries \u00e0 l\u2019\u00e9tat solide : rattacher chaque all\u00e9gation \u00e0 ses justificatifs<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3f52fc6f auto-p elementor-widget elementor-widget-heading\" data-id=\"3f52fc6f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Commencez par reformuler chaque affirmation relative \u00e0 la s\u00e9curit\u00e9 figurant dans le devis sous la forme d'une all\u00e9gation v\u00e9rifiable. Des termes tels que \u201c s\u00fbr \u201d, \u201c ininflammable \u201d ou \u201c sans propagation \u201d n'ont gu\u00e8re de valeur sur le plan des achats, \u00e0 moins que le fournisseur ne pr\u00e9cise l'objet test\u00e9, la m\u00e9thode utilis\u00e9e, les conditions d'essai, le r\u00e9sultat, le num\u00e9ro du rapport et la version du produit.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-cb2cc6ad auto-table elementor-widget elementor-widget-text-editor\" data-id=\"cb2cc6ad\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"cea-table-wrap\"><table><thead><tr><th>All\u00e9gation du fournisseur<\/th><th>Justificatifs \u00e0 demander<\/th><th>Question relative \u00e0 l'approbation<\/th><\/tr><\/thead><tbody><tr><td>Une chimie des cellules plus s\u00fbre<\/td><td>Description de la construction de la cellule et rapport d\u2019essais applicable en conditions abusives<\/td><td>La cellule test\u00e9e correspond-elle au fabricant, au mod\u00e8le, \u00e0 la capacit\u00e9 et \u00e0 la version indiqu\u00e9s dans la nomenclature propos\u00e9e ?<\/td><\/tr><tr><td>L'emballement thermique ne se propage pas<\/td><td>Rapport d\u2019essai de propagation \u00e0 l\u2019\u00e9chelle du module, du rack ou du syst\u00e8me, avec le montage d\u2019essai et les observations<\/td><td>Le montage d\u2019essai correspond-il \u00e0 l\u2019espacement, \u00e0 l\u2019enveloppe, \u00e0 la ventilation et \u00e0 l\u2019\u00e9tat de charge pr\u00e9vus pour le projet ?<\/td><\/tr><tr><td>Alerte pr\u00e9coce<\/td><td>Liste des capteurs, seuils d'alarme, matrice de cause \u00e0 effet du BMS et journaux d'\u00e9v\u00e9nements<\/td><td>Le syst\u00e8me d\u00e9tectera-t-il le pr\u00e9curseur concern\u00e9 et d\u00e9clenchera-t-il une r\u00e9ponse d\u00e9finie ?<\/td><\/tr><tr><td>Protection incendie automatique<\/td><td>Plans de d\u00e9tection et d\u2019extinction, interfaces, logique de d\u00e9clenchement de l\u2019extinction et plan de maintenance<\/td><td>La conception a-t-elle \u00e9t\u00e9 accept\u00e9e par l\u2019ing\u00e9nieur local en protection incendie et par l\u2019autorit\u00e9 comp\u00e9tente ?<\/td><\/tr><tr><td>Syst\u00e8me certifi\u00e9<\/td><td>Certificat, champ d'application, r\u00e9f\u00e9rence du mod\u00e8le, r\u00e9f\u00e9rence du rapport, \u00e9metteur et dur\u00e9e de validit\u00e9<\/td><td>Le certificat couvre-t-il exactement l'ensemble du syst\u00e8me achet\u00e9 ?<\/td><\/tr><\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ad2101c6 auto-p elementor-widget elementor-widget-heading\" data-id=\"ad2101c6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\"><strong>Avant de verser un acompte :<\/strong> Int\u00e9grez cette matrice au cahier des charges technique et attribuez \u00e0 chaque ligne le statut \u00ab Approuv\u00e9 \u00bb, \u00ab Sous conditions \u00bb ou \u00ab Ouvert \u00bb. Vous \u00e9viterez qu\u2019une all\u00e9gation de brochure devienne implicitement un crit\u00e8re de r\u00e9ception contractuel qu\u2019aucune des deux parties ne peut mesurer.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ba1c503c auto-h2 elementor-widget elementor-widget-heading\" data-id=\"ba1c503c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Lisez le nom du test avant de consulter le r\u00e9sultat<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7484f3ff auto-p elementor-widget elementor-widget-heading\" data-id=\"7484f3ff\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Chaque document r\u00e9pond \u00e0 une question diff\u00e9rente. <a href=\"https:\/\/unece.org\/transport\/dangerous-goods\/rev8-files\" target=\"_blank\" rel=\"noopener\">UN 38.3<\/a> traite des essais de transport des cellules et batteries au lithium ; il ne s'agit pas d'une \u00e9valuation compl\u00e8te des risques d'incendie li\u00e9s aux syst\u00e8mes fixes. <a href=\"https:\/\/www.ul.com\/services\/energy-storage-system-testing-and-certification\" target=\"_blank\" rel=\"noopener\">UL 9540<\/a> traite du processus de certification des syst\u00e8mes et \u00e9quipements de stockage d\u2019\u00e9nergie, tandis que <a href=\"https:\/\/www.ul.com\/services\/ul-9540a-test-method\" target=\"_blank\" rel=\"noopener\">UL 9540A<\/a> est une m\u00e9thode d\u2019essai qui sert \u00e0 \u00e9valuer les caract\u00e9ristiques de propagation d\u2019un incendie d\u00fb \u00e0 l\u2019emballement thermique. Relevez l\u2019\u00e9dition du rapport, le niveau auquel l\u2019essai a \u00e9t\u00e9 men\u00e9 et la r\u00e9vision du produit, puis comparez la configuration d\u2019essai et les limites d\u2019installation \u00e0 la nomenclature propos\u00e9e et \u00e0 l\u2019implantation sur site. Examinez s\u00e9par\u00e9ment le certificat du syst\u00e8me complet et le rapport d\u2019essai de propagation.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-cf7e6f38 auto-p elementor-widget elementor-widget-heading\" data-id=\"cf7e6f38\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Pour les projets fixes, il convient \u00e9galement de d\u00e9terminer quelle version des r\u00e8gles d'installation et de s\u00e9curit\u00e9 sera appliqu\u00e9e par les autorit\u00e9s locales. <a href=\"https:\/\/link.nfpa.org\/all-publications\/855\/2023\" target=\"_blank\" rel=\"noopener\">NFPA 855<\/a> et <a href=\"https:\/\/webstore.iec.ch\/en\/publication\/68297\" target=\"_blank\" rel=\"noopener\">IEC 62933-5-2:2025<\/a> peuvent \u00e9clairer le cahier des charges du projet, mais l\u2019entreprise EPC et le sp\u00e9cialiste de la s\u00e9curit\u00e9 incendie doivent d\u00e9terminer comment les exigences applicables se rapportent au pays, au site, \u00e0 l\u2019occupation des locaux et au code adopt\u00e9.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7f428b4f elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"7f428b4f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">V\u00e9rifiez si l'objet test\u00e9 \u00e9tait une cellule, un module, un rack, une armoire ou un conteneur complet.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Noter l'\u00e9tat de charge \u00e0 l'essai, la m\u00e9thode de d\u00e9clenchement, l'espacement, la ventilation et l'\u00e9tat de l'enceinte.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">V\u00e9rifiez si les portes, les panneaux, les conduits, les installations de chauffage, de ventilation et de climatisation ainsi que les syst\u00e8mes d'extinction correspondent \u00e0 la conception propos\u00e9e.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Demandez le rapport complet ou un extrait technique autoris\u00e9. Une image du certificat seule ne suffit pas.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Exigez que l\u2019entreprise EPC consigne quels r\u00e9sultats modifient l\u2019implantation, les distances de s\u00e9paration ou le plan d\u2019urgence.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8c751602 elementor-tablet-align-center elementor-align-center auto-cta elementor-widget elementor-widget-button\" data-id=\"8c751602\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"#elementor-action%3Aaction%3Dpopup%3Aopen%26settings%3DeyJpZCI6Ijk0OCIsInRvZ2dsZSI6ZmFsc2V9\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Demander un examen de s\u00e9curit\u00e9 du syst\u00e8me BESS sp\u00e9cifique \u00e0 un mod\u00e8le<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-859c0326 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"859c0326\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Verrouillez la nomenclature avant d'accepter tout rapport<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-be2bb512 auto-p elementor-widget elementor-widget-heading\" data-id=\"be2bb512\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Un rapport qui semble valable peut s\u2019av\u00e9rer non pertinent si l\u2019unit\u00e9 de s\u00e9rie utilise une cellule, un cadre de module, un jeu de barres, un fusible, un connecteur, un isolant, un circuit de liquide de refroidissement, un capteur ou un micrologiciel diff\u00e9rent. L\u2019acheteur devrait \u00e9tablir une r\u00e9f\u00e9rence ma\u00eetris\u00e9e reliant le devis, le plan d\u2019ensemble, le sch\u00e9ma unifilaire, la nomenclature, la version du logiciel et les justificatifs d\u2019essai.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-546a1d74 auto-p elementor-widget elementor-widget-heading\" data-id=\"546a1d74\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\"><strong>R\u00e8gle de contr\u00f4le des modifications :<\/strong> Une substitution qui touche \u00e0 la s\u00e9curit\u00e9 ne devrait pas \u00eatre accept\u00e9e sur la seule base d\u2019un courriel d\u2019achat. Exigez une notification d\u2019\u00e9cart technique qui pr\u00e9cise le motif du changement, les dangers r\u00e9\u00e9valu\u00e9s, les essais qui restent applicables et la n\u00e9cessit\u00e9 \u00e9ventuelle d\u2019un nouvel essai.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-15dba31a elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"15dba31a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Fabricant de la cellule, mod\u00e8le, description de la composition chimique, capacit\u00e9 et version de production<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Configuration des modules et des racks, espacement m\u00e9canique et m\u00e9thode d'interconnexion<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Mat\u00e9riel BMS, version du micrologiciel, types de capteurs et plages de mesure \u00e9talonn\u00e9es<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Protections c\u00f4t\u00e9 courant continu, contacteurs, fusibles, surveillance de l\u2019isolement et cha\u00eene d\u2019arr\u00eat d\u2019urgence<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Architecture de refroidissement et d\u00e9tection des d\u00e9faillances propres au mod\u00e8le : ventilateurs, filtres et circuits d\u2019air pour le refroidissement par air, et, lorsqu\u2019un circuit liquide est fourni, liquide de refroidissement, pompes et d\u00e9tection du d\u00e9bit et des fuites.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Composants de d\u00e9tection d'incendie, d'alarme, de ventilation, d'extinction et d'interface externe<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-697e76f6 auto-image elementor-widget elementor-widget-image\" data-id=\"697e76f6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"1536\" height=\"864\" src=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/07\/bess-thermal-runaway-safety-layers-1536x864.jpg\" class=\"attachment-1536x1536 size-1536x1536 wp-image-4333\" alt=\"Vue en coupe des dispositifs de s\u00e9curit\u00e9 \u00e0 plusieurs niveaux contre l&#039;emballement thermique \u00e0 l&#039;int\u00e9rieur d&#039;une armoire BESS\" srcset=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/07\/bess-thermal-runaway-safety-layers-1536x864.jpg 1536w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/07\/bess-thermal-runaway-safety-layers-300x169.jpg 300w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/07\/bess-thermal-runaway-safety-layers-1024x576.jpg 1024w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/07\/bess-thermal-runaway-safety-layers-768x432.jpg 768w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/07\/bess-thermal-runaway-safety-layers-600x338.jpg 600w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/07\/bess-thermal-runaway-safety-layers.jpg 1672w\" sizes=\"(max-width: 1536px) 100vw, 1536px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ba7580db auto-p elementor-widget elementor-widget-heading\" data-id=\"ba7580db\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">L\u2019illustration des niveaux de protection montre pourquoi la demande de devis doit relier la cellule, les voies de transfert thermique, la d\u00e9tection, l\u2019isolement \u00e9lectrique, l\u2019enveloppe et la r\u00e9ponse d\u2019urgence. Un acheteur qui compare les architectures peut consulter la <a href=\"https:\/\/www.solidess.com\/fr\/systemes-de-stockage-denergie-a-letat-solide\/\">pr\u00e9sentation g\u00e9n\u00e9rale des syst\u00e8mes de stockage d\u2019\u00e9nergie \u00e0 l\u2019\u00e9tat solide<\/a> pour orienter son choix, puis exiger des justificatifs propres au mod\u00e8le pour chaque niveau de protection de la conception finale.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1ce9c215 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"1ce9c215\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">V\u00e9rifier si la chaleur et les gaz peuvent atteindre l\u2019unit\u00e9 voisine<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-449af03d auto-p elementor-widget elementor-widget-heading\" data-id=\"449af03d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">La question pertinente ne se limite pas \u00e0 savoir si une cellule peut entrer en \u00e9tat d\u2019emballement thermique dans des conditions de sollicitation abusive. L\u2019\u00e9quipe du projet doit savoir ce qui se passe ensuite : o\u00f9 se propagent la chaleur, les flammes, les particules et les gaz ; si les cellules ou modules adjacents sont touch\u00e9s ; et comment le bo\u00eetier influe sur la pression et l\u2019exposition.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-209b7cb6 auto-p elementor-widget elementor-widget-heading\" data-id=\"209b7cb6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Confrontez le r\u00e9sultat \u00e0 l\u2019implantation r\u00e9elle, notamment \u00e0 l\u2019espacement des racks, aux travers\u00e9es de c\u00e2bles, \u00e0 la distance entre les armoires et aux zones occup\u00e9es \u00e0 proximit\u00e9. Pour les installations plus grandes, les principes du guide sur la <a href=\"https:\/\/www.solidess.com\/fr\/conception-du-bess-de-5-mwh\/\">conception d\u2019un BESS de 5 MWh<\/a> peuvent aider \u00e0 cadrer l\u2019int\u00e9gration du syst\u00e8me. L\u2019analyse des risques d\u2019incendie et d\u2019explosion doit rester propre \u00e0 la configuration du projet.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-38d7a491 elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"38d7a491\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">O\u00f9 les gaz chauds sont-ils cens\u00e9s \u00eatre \u00e9vacu\u00e9s, et peuvent-ils atteindre une prise d'air ou une issue de secours ?<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Qu\u2019est-ce qui emp\u00eache un incident au niveau d\u2019une seule cellule de provoquer l\u2019\u00e9chauffement des cellules, modules ou armoires adjacents ?<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Comment d\u00e9tecter la fum\u00e9e, mesurer la temp\u00e9rature et relever les indicateurs pertinents li\u00e9s aux gaz avant que la situation ne s\u2019aggrave ?<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Quelle isolation \u00e9lectrique est mise en place lors des phases d'alarme, de d\u00e9clenchement et d'arr\u00eat d'urgence ?<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Quels acc\u00e8s, quelle alimentation en eau et quelle distance de s\u00e9curit\u00e9 faut-il pr\u00e9voir, et quelles informations faut-il fournir aux services de secours ?<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1af3146d auto-h2 elementor-widget elementor-widget-heading\" data-id=\"1af3146d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Observer la logique de protection du BMS pendant les essais, au-del\u00e0 des affichages du tableau de bord<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c0373800 auto-p elementor-widget elementor-widget-heading\" data-id=\"c0373800\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Un \u00e9cran affichant des temp\u00e9ratures normales ne prouve pas que la protection fonctionnera en cas de d\u00e9faillance. Les syst\u00e8mes BMS, PCS, EMS, CVC et de lutte contre l'incendie doivent \u00e9changer les signaux appropri\u00e9s, attribuer correctement les priorit\u00e9s et mettre les \u00e9quipements dans un \u00e9tat de s\u00e9curit\u00e9 d\u00e9fini lorsqu'un capteur tombe en panne ou qu'une limite est d\u00e9pass\u00e9e.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8af03041 auto-table elementor-widget elementor-widget-text-editor\" data-id=\"8af03041\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"cea-table-wrap\"><table><thead><tr><th>Sc\u00e9nario observ\u00e9<\/th><th>\u00c9l\u00e9ments de preuve attendus<\/th><th>Point d'acceptation par l'acheteur<\/th><\/tr><\/thead><tbody><tr><td>Avertissement concernant la temp\u00e9rature de la cellule<\/td><td>Valeur en temps r\u00e9el, alarme horodat\u00e9e, emplacement concern\u00e9 et notification \u00e0 l'op\u00e9rateur<\/td><td>Le seuil d'alarme et le d\u00e9lai correspondent \u00e0 la matrice de causes et d'effets approuv\u00e9e<\/td><\/tr><tr><td>D\u00e9clenchement sur temp\u00e9rature<\/td><td>Restriction de charge\/d\u00e9charge suivie de la s\u00e9quence d\u2019isolation sp\u00e9cifi\u00e9e<\/td><td>Les contacteurs et le PCS r\u00e9agissent sans n\u00e9cessiter d'intervention manuelle sur le tableau de bord<\/td><\/tr><tr><td>Circuit ouvert\/court-circuit du capteur<\/td><td>Alarme de diagnostic, r\u00e8gle de fonctionnement en mode d\u00e9grad\u00e9 et consignes de maintenance<\/td><td>Une d\u00e9faillance du capteur ne doit pas \u00eatre interpr\u00e9t\u00e9e comme une mesure de temp\u00e9rature sans danger.<\/td><\/tr><tr><td>Perte de la fonction de refroidissement<\/td><td>Alarme applicable de ventilateur, de circuit d\u2019air, de d\u00e9bit, de pression ou de temp\u00e9rature, avec r\u00e9duction de puissance ou d\u00e9clenchement selon la r\u00e9ponse sp\u00e9cifi\u00e9e et \u00e9v\u00e9nement horodat\u00e9<\/td><td>Cette mesure prot\u00e8ge la batterie avant que la limite de temp\u00e9rature ne soit d\u00e9pass\u00e9e<\/td><\/tr><tr><td>Interruption des communications<\/td><td>Comportement de repli s\u00fbr du syst\u00e8me de gestion de la batterie (BMS), du syst\u00e8me de conversion de puissance (PCS) et des commandes de supervision<\/td><td>Chaque contr\u00f4leur dispose d\u2019un \u00e9tat de repli et d\u2019une proc\u00e9dure de reprise convenus.<\/td><\/tr><tr><td>Arr\u00eat d'urgence<\/td><td>Isolement d\u00e9fini des circuits CC et CA, maintien des services de s\u00e9curit\u00e9 et commande de r\u00e9armement<\/td><td>L'arr\u00eat d'urgence ne d\u00e9sactive pas les syst\u00e8mes de d\u00e9tection essentiels ni les communications d'urgence<\/td><\/tr><\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-eb5fe398 auto-p elementor-widget elementor-widget-heading\" data-id=\"eb5fe398\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Demandez au fournisseur d\u2019exporter le journal des \u00e9v\u00e9nements apr\u00e8s chaque signal d\u2019entr\u00e9e simul\u00e9 approuv\u00e9 et de le joindre au dossier FAT. Utilisez le <a href=\"https:\/\/www.solidess.com\/fr\/guide-dessai-de-reception-en-usine-de-bess\/\">Guide des essais de r\u00e9ception en usine BESS<\/a> pour consigner la configuration test\u00e9e, les points d\u2019essai que les t\u00e9moins doivent observer, les \u00e9v\u00e9nements horodat\u00e9s et les limites de r\u00e9ussite ou d\u2019\u00e9chec convenues. Classez s\u00e9par\u00e9ment les rapports applicables d\u2019emballement thermique et de propagation d\u2019incendie. Les simulations de la commande r\u00e9alis\u00e9es en pr\u00e9sence de t\u00e9moins ne remplacent pas ces rapports. Les acheteurs qui \u00e9valuent des armoires peuvent comparer cette logique de commande \u00e0 celle de la <a href=\"https:\/\/www.solidess.com\/fr\/product\/systeme-de-stockage-denergie-en-armoire-exterieure\/\">gamme ESS en armoire ext\u00e9rieure<\/a>, en rattachant les limites de r\u00e9ception finales au mod\u00e8le effectivement propos\u00e9 dans le devis.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2533bcd6 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"2533bcd6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">V\u00e9rifier la gestion thermique dans le cadre d'un profil de fonctionnement r\u00e9el<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-47f4079d auto-p elementor-widget elementor-widget-heading\" data-id=\"47f4079d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Une armoire qui atteint l\u2019objectif \u00e9nerg\u00e9tique mais perd sa marge de refroidissement pendant la pointe de production est inadapt\u00e9e. V\u00e9rifiez le mod\u00e8le propos\u00e9 au regard des conditions ambiantes du site, de l\u2019exposition solaire, de l\u2019altitude, de la poussi\u00e8re et de l\u2019acc\u00e8s pour la maintenance. L\u2019ESSA0100B-0215 de MegSolid indique des valeurs nominales de 100 kW et 215,04 kWh, avec refroidissement par air et fonctionnement de 0 \u00e0 45 \u00b0C. La r\u00e9f\u00e9rence Energon ci-dessous indique 261,24 kWh et 125 kVA, avec refroidissement liquide, fonctionnement de \u221220 \u00e0 55 \u00b0C et r\u00e9duction de puissance au-del\u00e0 de 45 \u00b0C. Communiquez le r\u00e9gime de fonctionnement et les conditions locales pour que le devis pr\u00e9cise le mod\u00e8le applicable, la plage d\u2019\u00e9nergie utilisable et les limites thermiques avant tout engagement sur le mat\u00e9riel. Une br\u00e8ve d\u00e9monstration \u00e0 vide ne suffit pas \u00e0 \u00e9tablir les performances en charge ou en d\u00e9charge soutenues.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-386eba51 auto-p elementor-widget elementor-widget-heading\" data-id=\"386eba51\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default translation-block\">L\u2019<a href=\"https:\/\/www.solidess.com\/fr\/product\/stockage-denergie-solide-liquide-megasolide\/\" target=\"_self\">ESS Energon de MegSolid \u00e0 refroidissement liquide de 261,24 kWh<\/a> donne \u00e0 votre entreprise EPC une configuration pr\u00e9cise \u00e0 examiner : 125 kVA de puissance apparente nominale c\u00f4t\u00e9 courant alternatif, des cellules LFP de 314 Ah et un refroidissement liquide intelligent. La page produit actuelle indique un fonctionnement de \u221220 \u00e0 55 \u00b0C, avec r\u00e9duction de puissance au-del\u00e0 de 45 \u00b0C. Les conditions ambiantes doivent donc entrer dans le dimensionnement. Demandez la configuration propos\u00e9e de refroidissement, de d\u00e9tection et de protection, accompagn\u00e9e des preuves de propagation propres au mod\u00e8le et de l\u2019\u00e9tude thermique du site. Si votre projet exige des cellules hybrides \u00e0 l\u2019\u00e9tat solide, pr\u00e9cisez cette option fournie dans le devis sign\u00e9 et la nomenclature (BOM).<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-27a039fc elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"27a039fc\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Transmettez le profil de charge et de d\u00e9charge \u00e0 pas horaire ou infra-horaire, ainsi que le r\u00e9gime maximal de charge et de d\u00e9charge pr\u00e9vu (C-rate).<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Indiquez les temp\u00e9ratures ambiantes minimale, normale et maximale \u00e0 l'emplacement de l'\u00e9quipement.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">V\u00e9rifier la capacit\u00e9 du syst\u00e8me CVC ou de refroidissement par liquide, l'alimentation auxiliaire et les interfaces d'alarme.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Mesurez l\u2019\u00e9cart de temp\u00e9rature entre les cellules ou entre les modules pendant le cycle de fonctionnement convenu pour les essais FAT.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">D\u00e9finissez les t\u00e2ches de maintenance propres \u00e0 l\u2019architecture fournie : circuits d\u2019air, filtres et ventilateurs, ainsi que liquide de refroidissement, pompes et \u00e9changeurs thermiques lorsque ces \u00e9l\u00e9ments sont pr\u00e9sents.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-cfdc06b5 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"cfdc06b5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Documenter les engagements de conception par les essais de r\u00e9ception en usine (FAT)<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-cca72592 auto-image elementor-widget elementor-widget-image\" data-id=\"cca72592\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"1536\" height=\"864\" src=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/07\/bess-factory-acceptance-test-1536x864.jpg\" class=\"attachment-1536x1536 size-1536x1536 wp-image-4334\" alt=\"Des ing\u00e9nieurs effectuant des essais de r\u00e9ception en usine sur une armoire de stockage d&#039;\u00e9nergie par batterie\" srcset=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/07\/bess-factory-acceptance-test-1536x864.jpg 1536w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/07\/bess-factory-acceptance-test-300x169.jpg 300w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/07\/bess-factory-acceptance-test-1024x576.jpg 1024w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/07\/bess-factory-acceptance-test-768x432.jpg 768w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/07\/bess-factory-acceptance-test-600x338.jpg 600w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/07\/bess-factory-acceptance-test.jpg 1672w\" sizes=\"(max-width: 1536px) 100vw, 1536px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5bd97054 auto-p elementor-widget elementor-widget-heading\" data-id=\"5bd97054\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Les essais de r\u00e9ception en usine devraient produire des justificatifs tra\u00e7ables au-del\u00e0 d\u2019une mise sous tension de d\u00e9monstration. L\u2019acheteur, l\u2019entreprise EPC ou un t\u00e9moin ind\u00e9pendant devrait approuver le protocole avant le d\u00e9placement, identifier les signaux d\u2019entr\u00e9e simul\u00e9s, fixer les crit\u00e8res de r\u00e9ussite et d\u2019\u00e9chec, et consigner les num\u00e9ros de s\u00e9rie ainsi que les versions du micrologiciel le jour des essais.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-663e09d2 elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"663e09d2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">V\u00e9rifiez les plaques signal\u00e9tiques, les num\u00e9ros de s\u00e9rie et la nomenclature approuv\u00e9e par rapport au bon de commande.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Examinez les relev\u00e9s des couples de serrage, le cheminement des c\u00e2bles, l\u2019isolement, la mise \u00e0 la terre, les joints d\u2019\u00e9tanch\u00e9it\u00e9 de l\u2019enveloppe et les circuits de liquide de refroidissement.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Tester la logique des alarmes, des d\u00e9clenchements, des verrouillages et des arr\u00eats d'urgence \u00e0 l'aide d'une injection contr\u00f4l\u00e9e de signaux.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">D\u00e9montrez les sc\u00e9narios de perte d\u2019alimentation auxiliaire, de communication et de refroidissement conform\u00e9ment au protocole.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">V\u00e9rifier les limites de fonctionnement du PCS et la cha\u00eene d'autorisations du BMS \u00e0 une puissance d'essai s\u00fbre.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Exporter les journaux d'\u00e9v\u00e9nements, les photographies, les rapports d'\u00e9talonnage, les non-conformit\u00e9s et les justificatifs de cl\u00f4ture.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Ne valider l'exp\u00e9dition qu'une fois que les \u00e9carts critiques auront \u00e9t\u00e9 corrig\u00e9s ou ma\u00eetris\u00e9s conform\u00e9ment au contrat.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-66920619 auto-p elementor-widget elementor-widget-heading\" data-id=\"66920619\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default translation-block\">Le <a href=\"https:\/\/www.solidess.com\/fr\/guide-des-rfq-pour-le-systeme-de-stockage-denergie-refroidi-par-liquide-de-261-kwh\/\" target=\"_self\">guide d\u00e9taill\u00e9 de demande de devis pour le BESS de 261 kWh \u00e0 refroidissement liquide<\/a> peut aider \u00e0 structurer l\u2019\u00e9change de donn\u00e9es avant le FAT. Pour l\u2019achat d\u2019une solution de taille conteneuris\u00e9e, appliquez la m\u00eame rigueur documentaire en examinant l\u2019<a href=\"https:\/\/www.solidess.com\/fr\/product\/systeme-de-stockage-denergie-conteneurise-megasolid-5000intl\/\" target=\"_self\">ESS conteneuris\u00e9 5000INTL<\/a>, car une enceinte plus grande soul\u00e8ve des questions suppl\u00e9mentaires d\u2019int\u00e9gration et d\u2019interfaces avec le site.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2e709a1f auto-h2 elementor-widget elementor-widget-heading\" data-id=\"2e709a1f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Reproduire les sc\u00e9narios de risque du site r\u00e9el lors des essais SAT<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9360809d auto-p elementor-widget elementor-widget-heading\" data-id=\"9360809d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Les essais de r\u00e9ception sur site confirment que les \u00e9quipements test\u00e9s en usine fonctionnent toujours correctement apr\u00e8s le transport, l\u2019installation et l\u2019int\u00e9gration. Ils doivent couvrir les r\u00e9glages finaux des protections, les adresses r\u00e9seau, les terminaisons de c\u00e2bles, les alimentations auxiliaires, les interfaces du syst\u00e8me incendie, les postes d\u2019arr\u00eat d\u2019urgence et les notifications \u00e0 distance.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a6f1a907 auto-p elementor-widget elementor-widget-heading\" data-id=\"a6f1a907\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\"><strong>Projets en Afrique du Sud :<\/strong> l\u2019entreprise EPC locale doit coordonner la conformit\u00e9 \u00e9lectrique, la conception incendie, l\u2019implantation du g\u00e9nie civil, les exigences du gestionnaire de r\u00e9seau et les proc\u00e9dures d\u2019exploitation avec les autorit\u00e9s et les professionnels concern\u00e9s. Les acheteurs qui recherchent un <a href=\"https:\/\/www.solidess.com\/fr\/ou-acheter-un-bess-a-semi-conducteurs-fiable-en-afrique-du-sud\/\">syst\u00e8me de stockage d'\u00e9nergie par batterie \u00e0 l'\u00e9tat solide fiable en Afrique du Sud<\/a> devraient donc \u00e9valuer le fournisseur du mat\u00e9riel et l\u2019\u00e9quipe d\u2019int\u00e9gration locale comme une seule cha\u00eene de r\u00e9alisation.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-da091000 elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"da091000\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">V\u00e9rifiez que le mod\u00e8le install\u00e9, les num\u00e9ros de s\u00e9rie, le micrologiciel et les r\u00e9glages des protections correspondent aux relev\u00e9s FAT.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Tester les alarmes locales et \u00e0 distance, les coupures de communication, les arr\u00eats d'urgence et les proc\u00e9dures de r\u00e9initialisation autoris\u00e9es.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">V\u00e9rifiez la ventilation, le drainage, le contr\u00f4le d'acc\u00e8s, la signalisation, les d\u00e9gagements et l'acc\u00e8s des intervenants.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">V\u00e9rifiez le dossier de passation, la liste des pi\u00e8ces de rechange, les relev\u00e9s de pr\u00e9sence aux formations et le calendrier d'entretien.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Organisez un exercice d'urgence document\u00e9 en pr\u00e9sence du propri\u00e9taire, de l'exploitant, du ma\u00eetre d'\u0153uvre (EPC) et des responsables de la s\u00e9curit\u00e9.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e502f611 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"e502f611\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">\u00c9valuez vos fournisseurs en fonction de la tra\u00e7abilit\u00e9, et non en fonction de l\u2019adjectif le plus percutant<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-31a85521 auto-p elementor-widget elementor-widget-heading\" data-id=\"31a85521\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Une fiche d'\u00e9valuation des appels d'offres permet de comparer les donn\u00e9es relatives \u00e0 la s\u00e9curit\u00e9 entre les diff\u00e9rentes offres. Elle met \u00e9galement en \u00e9vidence la diff\u00e9rence entre un fabricant capable de discuter de la technologie cellulaire et une \u00e9quipe de mise en \u0153uvre capable de prendre en charge les obligations li\u00e9es au syst\u00e8me, \u00e0 l'installation et au cycle de vie.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7b2aac50 auto-table elementor-widget elementor-widget-text-editor\" data-id=\"7b2aac50\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"cea-table-wrap\"><table><thead><tr><th>Domaine de d\u00e9cision<\/th><th>Une proposition convaincante<\/th><th>Signal d\u2019alerte<\/th><\/tr><\/thead><tbody><tr><td>Tra\u00e7abilit\u00e9 des mod\u00e8les<\/td><td>Les rapports, les dessins et les nomenclatures utilisent des identifiants de mod\u00e8le et de r\u00e9vision coh\u00e9rents<\/td><td>Certificats g\u00e9n\u00e9riques sans lien avec le produit mentionn\u00e9<\/td><\/tr><tr><td>Justificatifs relatifs \u00e0 l\u2019emballement thermique<\/td><td>Le p\u00e9rim\u00e8tre complet des tests, la configuration, les observations et les limites sont disponibles<\/td><td>Une phrase promotionnelle remplace les conditions du rapport<\/td><\/tr><tr><td>Logique de protection<\/td><td>Les r\u00e9ponses d\u00e9finies dans la matrice cause-effet approuv\u00e9e sont observ\u00e9es en pr\u00e9sence de t\u00e9moins et consign\u00e9es pendant les FAT.<\/td><td>Seule une d\u00e9monstration du tableau de bord en mode de fonctionnement normal est propos\u00e9e<\/td><\/tr><tr><td>Contr\u00f4le des modifications<\/td><td>Les substitutions ayant une incidence sur la s\u00e9curit\u00e9 doivent faire l'objet d'une \u00e9valuation technique et \u00eatre approuv\u00e9es par l'acheteur.<\/td><td>Le fournisseur se r\u00e9serve le droit, sans aucune restriction, de remplacer des composants.<\/td><\/tr><tr><td>Int\u00e9gration locale<\/td><td>Les responsabilit\u00e9s attribu\u00e9es \u00e0 l\u2019entreprise EPC, les interfaces avec le site et les crit\u00e8res des essais SAT sont document\u00e9s.<\/td><td>Le p\u00e9rim\u00e8tre du fabricant s\u2019arr\u00eate sans attribution claire des responsabilit\u00e9s locales.<\/td><\/tr><tr><td>Transfert et cycle de vie<\/td><td>La formation, les pi\u00e8ces de rechange, la maintenance, les donn\u00e9es relatives aux incidents et les mises \u00e0 jour des documents sont d\u00e9finies<\/td><td>La r\u00e9ception se termine \u00e0 la livraison sans dossier de remise ma\u00eetris\u00e9.<\/td><\/tr><\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d1c0fb97 auto-p elementor-widget elementor-widget-heading\" data-id=\"d1c0fb97\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Les listes de fabricants peuvent faciliter un premier rep\u00e9rage, notamment ce guide qui pr\u00e9sente les <a href=\"https:\/\/www.solidess.com\/fr\/top-10-solid-state-battery-manufacturers-in-china-for-ess-buyers\/\">fabricants de batteries \u00e0 l\u2019\u00e9tat solide en Chine<\/a>, mais elles ne remplacent pas les v\u00e9rifications propres au projet. Utilisez le <a href=\"https:\/\/www.solidess.com\/fr\/guide-sur-le-stockage-denergie-a-letat-solide-ci-2026\/\">Guide sur le stockage d'\u00e9nergie \u00e0 l'\u00e9tat solide C&amp;I<\/a> pour pr\u00e9s\u00e9lectionner les architectures, puis appliquez la grille des justificatifs \u00e0 l\u2019offre pr\u00e9cise.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8edb021a auto-h2 elementor-widget elementor-widget-heading\" data-id=\"8edb021a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Joindre un dossier complet de donn\u00e9es de s\u00e9curit\u00e9 \u00e0 la demande de devis<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6382614b auto-p elementor-widget elementor-widget-heading\" data-id=\"6382614b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">La capacit\u00e9 de la batterie ne suffit pas au fournisseur pour concevoir une r\u00e9ponse de s\u00e9curit\u00e9 adapt\u00e9e. Transmettez le profil de fonctionnement, le plan du site, les limites des conditions ambiantes, la configuration du r\u00e9seau, la strat\u00e9gie incendie, les exigences de communication et les contraintes impos\u00e9es par les autorit\u00e9s avant de demander une offre technique ferme.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b805bd67 elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"b805bd67\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">\u00c9nergie utilisable requise, puissance c\u00f4t\u00e9 courant alternatif, r\u00e9gime de surcharge et profil de charge et de d\u00e9charge<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Sch\u00e9ma unifilaire, point de raccordement, principe de mise \u00e0 la terre et niveau de courant de d\u00e9faut disponible<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Coordonn\u00e9es du site, altitude, conditions environnementales, poussi\u00e8re, corrosion et risque d'inondation<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Local technique ou am\u00e9nagement ext\u00e9rieur, distances de s\u00e9paration et interfaces avec les zones occup\u00e9es<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Normes applicables, proc\u00e9dure d'autorisation et autorit\u00e9 comp\u00e9tente<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Exigences de d\u00e9tection incendie, d\u2019alarme, d\u2019extinction, d\u2019alimentation en eau, de ventilation et d\u2019intervention des secours<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Protocole SCADA\/EMS, destinations des alarmes \u00e0 distance et responsabilit\u00e9s en mati\u00e8re de cybers\u00e9curit\u00e9<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Rapports requis, points d\u2019essai \u00e0 observer en pr\u00e9sence de t\u00e9moins lors des FAT et SAT, formation, pi\u00e8ces de rechange et langue des documents<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-158a7acd auto-p elementor-widget elementor-widget-heading\" data-id=\"158a7acd\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Indiquez, pour le mod\u00e8le MegSolid propos\u00e9, le r\u00e9gime de fonctionnement requis et les documents de s\u00e9curit\u00e9 qui restent \u00e0 fournir. Demandez une offre unique couvrant les \u00e9quipements et leurs justificatifs. L\u2019entreprise EPC dispose ainsi d\u2019un dossier \u00e0 examiner, et l\u2019acheteur d\u2019un p\u00e9rim\u00e8tre \u00e0 chiffrer. Le <a href=\"https:\/\/www.solidess.com\/fr\/ressource\/\">Centre de ressources MegSolid<\/a> et <a href=\"https:\/\/www.solidess.com\/fr\/a-propos-de-megsolid\/\">la pr\u00e9sentation de l\u2019entreprise<\/a> donnent des informations g\u00e9n\u00e9rales. Votre demande devrait pr\u00e9ciser les proc\u00e8s-verbaux d\u2019essai, les interfaces du syst\u00e8me incendie et les responsabilit\u00e9s de mise en service n\u00e9cessaires au projet. La prochaine \u00e9tape consiste \u00e0 obtenir une offre propre au mod\u00e8le, au-del\u00e0 d\u2019une nouvelle brochure sur la chimie.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7f2282d6 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"7f2282d6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Approuver le dossier de justificatifs avant d\u2019approuver le mat\u00e9riel<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3160470a auto-p elementor-widget elementor-widget-heading\" data-id=\"3160470a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Face au risque d\u2019emballement thermique des batteries \u00e0 l\u2019\u00e9tat solide, \u00e9vitez aussi bien la confiance aveugle que le rejet syst\u00e9matique. Approuvez le BESS lorsque l\u2019all\u00e9gation de chimie plus s\u00fbre, la nomenclature exacte, les justificatifs d\u2019essai applicables, la logique de protection, la conception thermique, les interfaces du syst\u00e8me incendie et les relev\u00e9s FAT\/SAT forment un dossier tra\u00e7able qui \u00e9nonce clairement les limites.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-62e360b5 auto-p elementor-widget elementor-widget-heading\" data-id=\"62e360b5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Cette m\u00e9thode tient compte des aspects commerciaux et techniques. Les justificatifs manquants deviennent des clarifications du devis, des points d\u2019arr\u00eat contractuels ou des risques chiffr\u00e9s, au lieu de provoquer des litiges au stade de la mise en service. Elle permet aussi \u00e0 MegSolid et \u00e0 l\u2019entreprise EPC locale de r\u00e9pondre \u00e0 une exigence d\u00e9finie, sans devoir deviner ce que signifie \u00ab batterie \u00e0 l\u2019\u00e9tat solide s\u00fbre \u00bb pour le site de l\u2019acheteur.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a5803ee6 elementor-tablet-align-center elementor-align-center auto-cta elementor-widget elementor-widget-button\" data-id=\"a5803ee6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"#elementor-action%3Aaction%3Dpopup%3Aopen%26settings%3DeyJpZCI6Ijk0OCIsInRvZ2dsZSI6ZmFsc2V9\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Transmettez votre profil de fonctionnement et votre liste de contr\u00f4le de s\u00e9curit\u00e9<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-020b03d1 auto-faq e-flex e-con-boxed e-con e-child\" data-id=\"020b03d1\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-22c872c4 elementor-widget elementor-widget-heading\" data-id=\"22c872c4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">FAQ<\/h2>\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-f5d9cca9 e-con-full e-flex e-con e-child\" data-id=\"f5d9cca9\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ee8ff4fd elementor-widget elementor-widget-n-accordion\" data-id=\"ee8ff4fd\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;default_state&quot;:&quot;all_collapsed&quot;,&quot;max_items_expended&quot;:&quot;one&quot;,&quot;n_accordion_animation_duration&quot;:{&quot;unit&quot;:&quot;ms&quot;,&quot;size&quot;:400,&quot;sizes&quot;:[]}}\" data-widget_type=\"nested-accordion.default\">\n\t\t\t\t\t\t\t<div class=\"e-n-accordion\" aria-label=\"Accord\u00e9on. Ouvrez les liens \u00e0 l&#039;aide de la touche Entr\u00e9e ou de la barre d&#039;espace, fermez-les avec la touche \u00c9chap et naviguez \u00e0 l&#039;aide des touches fl\u00e9ch\u00e9es.\">\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-4000\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"1\" tabindex=\"0\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-4000\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Une batterie \u00e0 l'\u00e9tat solide peut-elle subir un emballement thermique ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-4000\" class=\"elementor-element elementor-element-f7e0fd92 e-con-full e-flex e-con e-child\" data-id=\"f7e0fd92\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-4000\" class=\"elementor-element elementor-element-52915fce e-con-full e-flex e-con e-child\" data-id=\"52915fce\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-bb940d2b elementor-widget elementor-widget-heading\" data-id=\"bb940d2b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Une conception \u00e0 l'\u00e9tat solide ou hybride \u00e0 l'\u00e9tat solide peut r\u00e9duire le risque d\u2019emballement thermique, mais les acheteurs ne doivent pas consid\u00e9rer que ce risque est nul. Les d\u00e9fauts \u00e9lectriques, les dommages m\u00e9caniques, les d\u00e9fauts de fabrication, la charge excessive de la batterie, l\u2019\u00e9chauffement externe et l\u2019int\u00e9gration au syst\u00e8me n\u00e9cessitent toujours des essais sp\u00e9cifiques au mod\u00e8le et une protection \u00e0 plusieurs niveaux.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-4001\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"2\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-4001\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> La m\u00e9thode d\u2019essai UL 9540A prouve-t-elle qu\u2019un BESS ne peut pas prendre feu ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-4001\" class=\"elementor-element elementor-element-bab165ce e-con-full e-flex e-con e-child\" data-id=\"bab165ce\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-4001\" class=\"elementor-element elementor-element-36e148a0 e-con-full e-flex e-con e-child\" data-id=\"36e148a0\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-b56b0801 elementor-widget elementor-widget-heading\" data-id=\"b56b0801\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Non. UL 9540A est une m\u00e9thode d\u2019essai qui \u00e9value les caract\u00e9ristiques de propagation d\u2019un incendie d\u00fb \u00e0 l\u2019emballement thermique dans des conditions d\u00e9finies. Examinez le niveau test\u00e9, la configuration, l\u2019\u00e9tat de charge, les observations et les limites, puis comparez-les \u00e0 l\u2019installation propos\u00e9e.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-4002\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"3\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-4002\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Les essais UN 38.3 suffisent-ils pour approuver un BESS stationnaire \u00e0 l\u2019\u00e9tat solide ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-4002\" class=\"elementor-element elementor-element-25c3dcb2 e-con-full e-flex e-con e-child\" data-id=\"25c3dcb2\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-4002\" class=\"elementor-element elementor-element-0ac6e2cc e-con-full e-flex e-con e-child\" data-id=\"0ac6e2cc\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-aee2feba elementor-widget elementor-widget-heading\" data-id=\"aee2feba\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Non. UN 38.3 traite des essais de transport des cellules et batteries au lithium. L\u2019approbation d\u2019un syst\u00e8me fixe exige aussi des justificatifs applicables au produit, \u00e0 l\u2019installation et au projet, notamment pour la logique de protection, les interfaces du syst\u00e8me incendie, les FAT\/SAT et l\u2019acceptation au titre du code local.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-4003\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"4\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-4003\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Quels \u00e9l\u00e9ments un rapport d'essai d'emballement thermique doit-il contenir ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-4003\" class=\"elementor-element elementor-element-eef49a75 e-con-full e-flex e-con e-child\" data-id=\"eef49a75\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-4003\" class=\"elementor-element elementor-element-5fe64f24 e-con-full e-flex e-con e-child\" data-id=\"5fe64f24\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-9fb6da00 elementor-widget elementor-widget-heading\" data-id=\"9fb6da00\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Il doit pr\u00e9ciser la m\u00e9thode d'essai, le mod\u00e8le de cellule ou de syst\u00e8me, la r\u00e9vision, le niveau d'essai, l'\u00e9tat de charge, la m\u00e9thode de d\u00e9clenchement, la configuration physique, la ventilation, les mesures, les observations et les r\u00e9sultats. L'acheteur doit pouvoir faire correspondre ces d\u00e9tails \u00e0 la nomenclature propos\u00e9e.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-4004\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"5\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-4004\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Pourquoi la nomenclature doit-elle correspondre au rapport de s\u00e9curit\u00e9 ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-4004\" class=\"elementor-element elementor-element-9595431c e-con-full e-flex e-con e-child\" data-id=\"9595431c\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-4004\" class=\"elementor-element elementor-element-dcef4cd6 e-con-full e-flex e-con e-child\" data-id=\"dcef4cd6\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-2c4486f9 elementor-widget elementor-widget-heading\" data-id=\"2c4486f9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Toute modification apport\u00e9e aux cellules, au mat\u00e9riel des modules, \u00e0 l'espacement, \u00e0 l'isolation, au refroidissement, aux capteurs, au micrologiciel ou aux composants de s\u00e9curit\u00e9 incendie peut modifier le comportement du syst\u00e8me. Une nomenclature (BOM) contr\u00f4l\u00e9e et un processus de gestion des \u00e9carts permettent de v\u00e9rifier si les donn\u00e9es existantes restent valables apr\u00e8s un remplacement.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-4005\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"6\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-4005\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Quelles fonctions du BMS faut-il observer pendant les essais de r\u00e9ception en usine (FAT) ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-4005\" class=\"elementor-element elementor-element-93e647d3 e-con-full e-flex e-con e-child\" data-id=\"93e647d3\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-4005\" class=\"elementor-element elementor-element-b23cc6f5 e-con-full e-flex e-con e-child\" data-id=\"b23cc6f5\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-49486849 elementor-widget elementor-widget-heading\" data-id=\"49486849\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Observez l\u2019alerte de temp\u00e9rature et le d\u00e9clenchement sur temp\u00e9rature, la d\u00e9tection des d\u00e9fauts de capteurs, la perte de refroidissement, la perte de communication, la limitation de la charge et de la d\u00e9charge, l\u2019isolement assur\u00e9 par les contacteurs, l\u2019arr\u00eat d\u2019urgence et l\u2019enregistrement des \u00e9v\u00e9nements. Utilisez les seuils approuv\u00e9s et les crit\u00e8res de r\u00e9ussite ou d\u2019\u00e9chec plut\u00f4t qu\u2019une d\u00e9monstration informelle.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-4006\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"7\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-4006\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Un syst\u00e8me de stockage d'\u00e9nergie par batterie (BESS) \u00e0 refroidissement liquide \u00e9limine-t-il le risque d'emballement thermique ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-4006\" class=\"elementor-element elementor-element-9f663190 e-con-full e-flex e-con e-child\" data-id=\"9f663190\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-4006\" class=\"elementor-element elementor-element-8d2d73c8 e-con-full e-flex e-con e-child\" data-id=\"8d2d73c8\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-05b673f0 elementor-widget elementor-widget-heading\" data-id=\"05b673f0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Non. Le refroidissement liquide peut am\u00e9liorer la r\u00e9gulation de temp\u00e9rature, mais il n\u2019\u00e9limine pas tous les d\u00e9fauts internes ou externes. V\u00e9rifiez les performances thermiques, la surveillance du d\u00e9bit et la d\u00e9tection des fuites, la logique d\u2019alarme, les t\u00e2ches de maintenance et la r\u00e9action \u00e0 une perte de refroidissement.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-4007\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"8\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-4007\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Un acheteur doit-il demander le rapport complet UL 9540A ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-4007\" class=\"elementor-element elementor-element-bea39b36 e-con-full e-flex e-con e-child\" data-id=\"bea39b36\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-4007\" class=\"elementor-element elementor-element-ccffef0e e-con-full e-flex e-con e-child\" data-id=\"ccffef0e\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-e1d7afec elementor-widget elementor-widget-heading\" data-id=\"e1d7afec\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Demandez suffisamment d\u2019informations techniques autoris\u00e9es pour comprendre la configuration test\u00e9e, les conditions, les r\u00e9sultats et les limites. Une image du certificat ou un r\u00e9sum\u00e9 promotionnel peut ne pas suffire \u00e0 montrer la pertinence de l\u2019essai pour l\u2019installation propos\u00e9e.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-4008\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"9\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-4008\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Pour la s\u00e9curit\u00e9 du BESS, quelle diff\u00e9rence y a-t-il entre les essais de r\u00e9ception en usine (FAT) et les essais de r\u00e9ception sur site (SAT) ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-4008\" class=\"elementor-element elementor-element-4944a78b e-con-full e-flex e-con e-child\" data-id=\"4944a78b\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-4008\" class=\"elementor-element elementor-element-5636e61c e-con-full e-flex e-con e-child\" data-id=\"5636e61c\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-3de1440c elementor-widget elementor-widget-heading\" data-id=\"3de1440c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Les essais FAT v\u00e9rifient le mat\u00e9riel fabriqu\u00e9, la logique de protection et les relev\u00e9s avant l\u2019exp\u00e9dition. Les essais SAT v\u00e9rifient le syst\u00e8me install\u00e9, les r\u00e9glages d\u00e9finitifs, les interfaces du site, les commandes d\u2019urgence, les communications et la remise de l\u2019installation apr\u00e8s le transport et l\u2019int\u00e9gration.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-4009\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"10\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-4009\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Qui devrait approuver la strat\u00e9gie de protection incendie du BESS ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-4009\" class=\"elementor-element elementor-element-0394c0ce e-con-full e-flex e-con e-child\" data-id=\"0394c0ce\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-4009\" class=\"elementor-element elementor-element-d18ef92a e-con-full e-flex e-con e-child\" data-id=\"d18ef92a\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-5182d578 elementor-widget elementor-widget-heading\" data-id=\"5182d578\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">L\u2019\u00e9quipe du projet devrait d\u00e9signer un sp\u00e9cialiste local qualifi\u00e9 de la s\u00e9curit\u00e9 incendie et une entreprise EPC pour mettre en relation les donn\u00e9es du fabricant avec le site, l\u2019occupation des locaux, le code applicable et les exigences de l\u2019autorit\u00e9 comp\u00e9tente. Un plan g\u00e9n\u00e9rique du fournisseur de batteries ne devrait pas \u00eatre consid\u00e9r\u00e9 comme une approbation locale.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-40010\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"11\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-40010\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Quelles donn\u00e9es relatives au site ont une incidence sur la s\u00fbret\u00e9 thermique ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-40010\" class=\"elementor-element elementor-element-5bc4237a e-con-full e-flex e-con e-child\" data-id=\"5bc4237a\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-40010\" class=\"elementor-element elementor-element-6353f333 e-con-full e-flex e-con e-child\" data-id=\"6353f333\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-636b82eb elementor-widget elementor-widget-heading\" data-id=\"636b82eb\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Parmi les param\u00e8tres importants, on peut citer la temp\u00e9rature ambiante, l\u2019altitude, l\u2019exposition au soleil, la ventilation, la disposition des enceintes, les distances de s\u00e9paration, l\u2019occupation des locaux et des zones \u00e0 proximit\u00e9, l\u2019exposition aux inondations et \u00e0 la corrosion, le profil d\u2019utilisation, l\u2019\u00e9tat du r\u00e9seau \u00e9lectrique et les voies d\u2019acc\u00e8s d\u2019urgence.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-40011\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"12\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-40011\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Comment comparer les fournisseurs lorsque leurs all\u00e9gations en mati\u00e8re de s\u00e9curit\u00e9 divergent ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-40011\" class=\"elementor-element elementor-element-3ca1ead8 e-con-full e-flex e-con e-child\" data-id=\"3ca1ead8\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-40011\" class=\"elementor-element elementor-element-36bda5cb e-con-full e-flex e-con e-child\" data-id=\"36bda5cb\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-7a0516ed elementor-widget elementor-widget-heading\" data-id=\"7a0516ed\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Utilisez une matrice commune \u00ab affirmation-preuve \u00bb. \u00c9valuez la tra\u00e7abilit\u00e9 du mod\u00e8le, la pertinence des rapports, les donn\u00e9es de propagation, la logique de protection, le contr\u00f4le des modifications, l'int\u00e9gration locale, les tests FAT\/SAT et le soutien tout au long du cycle de vie, plut\u00f4t que de classer les fournisseurs en fonction de leurs arguments promotionnels.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-40012\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"13\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-40012\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Que dois-je envoyer \u00e0 MegSolid pour une \u00e9valuation sp\u00e9cifique \u00e0 un mod\u00e8le ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-40012\" class=\"elementor-element elementor-element-2cfb95a8 e-con-full e-flex e-con e-child\" data-id=\"2cfb95a8\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-40012\" class=\"elementor-element elementor-element-4d6df9bc e-con-full e-flex e-con e-child\" data-id=\"4d6df9bc\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-3a6edf58 elementor-widget elementor-widget-heading\" data-id=\"3a6edf58\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Transmettez l\u2019\u00e9nergie utilisable requise, la puissance requise c\u00f4t\u00e9 courant alternatif, le profil de charge et de d\u00e9charge, le sch\u00e9ma unifilaire, les conditions du site, les contraintes d\u2019implantation, les normes applicables, les interfaces du syst\u00e8me incendie, les besoins de communication et les points d\u2019essai \u00e0 observer en pr\u00e9sence de t\u00e9moins lors des FAT et SAT.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Liste de contr\u00f4le des achats destin\u00e9e \u00e0 v\u00e9rifier les rapports d'essai des syst\u00e8mes de stockage d'\u00e9nergie par batterie \u00e0 semi-conducteurs (BESS), le contr\u00f4le de la nomenclature, la logique de protection, les preuves relatives aux essais d'acceptation en usine (FAT) et l'acceptation sur site avant validation.<\/p>","protected":false},"author":4,"featured_media":4332,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"_joinchat":[],"footnotes":""},"categories":[1,711],"tags":[167,166,168,165],"class_list":["post-4335","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-bess","category-solid-state-battery-technology","tag-battery-procurement","tag-bess-safety","tag-fat-and-sat","tag-solid-state-battery-thermal-runaway"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/posts\/4335","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/comments?post=4335"}],"version-history":[{"count":18,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/posts\/4335\/revisions"}],"predecessor-version":[{"id":6283,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/posts\/4335\/revisions\/6283"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/media\/4332"}],"wp:attachment":[{"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/media?parent=4335"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/categories?post=4335"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/tags?post=4335"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}