{"id":4445,"date":"2026-08-03T16:58:34","date_gmt":"2026-08-03T08:58:34","guid":{"rendered":"https:\/\/www.solidess.com\/?p=4445"},"modified":"2026-11-09T18:20:34","modified_gmt":"2026-11-09T10:20:34","slug":"comment-evaluer-un-systeme-de-stockage-denergie-par-batterie-bess-dun-equipementier-oem-pour-les-usines-bresiliennes","status":"publish","type":"post","link":"https:\/\/www.solidess.com\/fr\/how-to-evaluate-an-oem-battery-energy-storage-system-bess-for-brazilian-factories\/","title":{"rendered":"Comment \u00e9valuer un syst\u00e8me de stockage d\u2019\u00e9nergie par batterie (BESS) OEM pour les usines br\u00e9siliennes"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"4445\" class=\"elementor elementor-4445\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-bf4793c e-con-full auto-article-root e-flex e-con e-parent\" data-id=\"bf4793c\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-2032ed01 auto-p elementor-widget elementor-widget-heading\" data-id=\"2032ed01\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Dans l\u2019industrie manufacturi\u00e8re br\u00e9silienne, votre usine peut obtenir un prix bas pour un BESS et devoir encore payer, apr\u00e8s livraison, le PCS, l\u2019appareillage \u00e9lectrique et l\u2019int\u00e9gration qui manquent. Comparez l\u2019armoire ESSA MegSolid de 100 kW \/ 215,04 kWh \u00e0 une solution conteneuris\u00e9e con\u00e7ue pour le projet, au m\u00eame point de livraison c\u00f4t\u00e9 courant alternatif. Communiquez le mode de fonctionnement et le p\u00e9rim\u00e8tre de l\u2019entreprise EPC locale afin que l\u2019offre pr\u00e9cise les \u00e9quipements et les responsabilit\u00e9s compris dans l\u2019achat. Utilisez le <strong><a href=\"https:\/\/www.solidess.com\/fr\/achat-de-stockage-denergie-commercial\/\" target=\"_blank\" style=\"color:#61CE70\">guide d\u2019achat de syst\u00e8mes de stockage d\u2019\u00e9nergie \u00e0 usage commercial<\/a><\/strong> pour d\u00e9finir le p\u00e9rim\u00e8tre du fournisseur et de l\u2019entreprise EPC locale, puis comparez la <strong><a href=\"https:\/\/www.solidess.com\/fr\/piles\/stockage-denergie-ci\/\" target=\"_blank\" style=\"color:#61CE70\">gamme de stockage d'\u00e9nergie C&amp;I de MegSolid<\/a><\/strong> \u00e0 ce p\u00e9rim\u00e8tre.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3810785c elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"3810785c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>D\u00e9finissez les charges critiques et le mode de fonctionnement requis avant d\u2019envoyer une demande de devis.<\/strong><\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>D\u00e9terminez la puissance nominale et la puissance de pointe c\u00f4t\u00e9 courant alternatif avant de comparer les \u00e9nergies nominales des batteries.<\/strong><\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>Attribuez les responsabilit\u00e9s relatives au syst\u00e8me de conversion de puissance (PCS), aux commandes, au transformateur, \u00e0 l\u2019appareillage \u00e9lectrique, \u00e0 l\u2019installation et \u00e0 la mise en service.<\/strong><\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>Demandez les documents sp\u00e9cifiques au mod\u00e8le, les certificats, les conditions de garantie et les justificatifs des tests FAT\/SAT avant de valider le bon de commande.<\/strong><\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-60106d08 auto-p elementor-widget elementor-widget-heading\" data-id=\"60106d08\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Donnez \u00e0 l\u2019usine br\u00e9silienne et \u00e0 l\u2019entreprise EPC locale un m\u00eame p\u00e9rim\u00e8tre \u00e0 chiffrer : le r\u00e9gime de production mesur\u00e9, la batterie et le PCS retenus, la plage d\u2019\u00e9nergie utilisable c\u00f4t\u00e9 courant alternatif, les interfaces de raccordement et de protection et les responsabilit\u00e9s de r\u00e9ception. L\u2019\u00e9quipe locale d\u00e9finit la proc\u00e9dure d\u2019approbation du site et le p\u00e9rim\u00e8tre des travaux \u00e9lectriques et de g\u00e9nie civil \u00e0 r\u00e9aliser. L\u2019offre du fournisseur devrait pr\u00e9ciser exactement les \u00e9quipements, les documents, la livraison et l\u2019assistance dont il se chargera.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9368a056 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"9368a056\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">D\u00e9finir le besoin de production avant de demander un devis BESS<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7928716c auto-image elementor-widget elementor-widget-image\" data-id=\"7928716c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"1254\" height=\"1254\" src=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/oem-bess-system-scope.jpg\" class=\"attachment-1536x1536 size-1536x1536 wp-image-4443\" alt=\"Sch\u00e9ma illustrant les interfaces de stockage par batterie entre une usine, un syst\u00e8me de conversion d&#039;\u00e9nergie, le r\u00e9seau \u00e9lectrique, une installation solaire et un groupe \u00e9lectrog\u00e8ne.\" srcset=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/oem-bess-system-scope.jpg 1254w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/oem-bess-system-scope-300x300.jpg 300w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/oem-bess-system-scope-1024x1024.jpg 1024w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/oem-bess-system-scope-150x150.jpg 150w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/oem-bess-system-scope-768x768.jpg 768w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/oem-bess-system-scope-600x600.jpg 600w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/oem-bess-system-scope-100x100.jpg 100w\" sizes=\"(max-width: 1254px) 100vw, 1254px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-59e08f9 elementor-tablet-align-center elementor-align-center auto-cta elementor-widget elementor-widget-button\" data-id=\"59e08f9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"#elementor-action%3Aaction%3Dpopup%3Aopen%26settings%3DeyJpZCI6Ijk0OCIsInRvZ2dsZSI6ZmFsc2V9\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Construire le p\u00e9rim\u00e8tre BESS de mon usine<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-97093b22 auto-p elementor-widget elementor-widget-heading\" data-id=\"97093b22\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Un syst\u00e8me de stockage d'\u00e9nergie par batterie peut \u00eatre envisag\u00e9 pour plusieurs objectifs d'exploitation, notamment le soutien de certaines charges, la coordination avec la production sur site, la coordination avec les groupes \u00e9lectrog\u00e8nes ou une strat\u00e9gie planifi\u00e9e de gestion de la charge. Ces objectifs ne sont pas interchangeables. Chacun d'entre eux modifie la puissance et l'\u00e9nergie requises, les commandes, les dispositifs de protection et les crit\u00e8res d'acceptation du site.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-84a00013 auto-p elementor-widget elementor-widget-heading\" data-id=\"84a00013\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Avant de contacter un fabricant de BESS ou un fournisseur OEM de BESS, r\u00e9partissez les charges de l\u2019usine en groupes de fonctionnement distincts. L\u2019\u00e9quipe du projet devrait identifier les charges qui doivent rester sous tension, celles qui peuvent fonctionner pendant une dur\u00e9e d\u00e9finie et celles qui peuvent \u00eatre d\u00e9lest\u00e9es ou reprogramm\u00e9es. Cette classification d\u00e9finit un p\u00e9rim\u00e8tre \u00e9lectrique concret et \u00e9vite d\u2019\u00e9valuer un devis uniquement \u00e0 partir d\u2019une valeur nominale en kWh.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8e0e98df auto-p elementor-widget elementor-widget-heading\" data-id=\"8e0e98df\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Demandez d\u2019abord le meilleur profil de charge disponible pour l\u2019usine, de pr\u00e9f\u00e9rence relev\u00e9 par intervalles de 15 ou 30 minutes, ainsi que les pointes de courte dur\u00e9e connues et les changements de proc\u00e9d\u00e9 pr\u00e9vus. Une valeur mensuelle de consommation ne suffit pas \u00e0 \u00e9tablir le profil de puissance requis par un syst\u00e8me de stockage d\u2019\u00e9nergie commercial ou industriel. L\u2019acheteur devrait aussi pr\u00e9ciser si le syst\u00e8me doit fonctionner avec le r\u00e9seau, le photovolta\u00efque, un groupe \u00e9lectrog\u00e8ne, un contr\u00f4leur de micror\u00e9seau ou un tableau d\u00e9fini pour les charges critiques.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-faf3e61b auto-p elementor-widget elementor-widget-heading\" data-id=\"faf3e61b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default translation-block\">Le <strong><a href=\"https:\/\/www.solidess.com\/fr\/bess\/\" target=\"_blank\" style=\"color:#61CE70\">portail des solutions BESS<\/a><\/strong> de MegSolid est un point de d\u00e9part pour examiner les cat\u00e9gories de stockage d\u2019\u00e9nergie de l\u2019entreprise. Les informations sur ces cat\u00e9gories peuvent faciliter les premi\u00e8res discussions, mais elles ne remplacent ni une \u00e9tude sur site, ni un sch\u00e9ma unifilaire, ni une \u00e9tude de charge, ni un examen de la conception propre au projet.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-91e599fa auto-table elementor-widget elementor-widget-text-editor\" data-id=\"91e599fa\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"cea-table-wrap\"><table><tbody><\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5bec4c5a auto-h2 elementor-widget elementor-widget-heading\" data-id=\"5bec4c5a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">D\u00e9terminer la puissance c\u00f4t\u00e9 courant alternatif avant de comparer l\u2019\u00e9nergie des batteries<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-593d357c auto-image elementor-widget elementor-widget-image\" data-id=\"593d357c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"1254\" height=\"1254\" src=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/outdoor-ci-energy-storage-cabinet.jpg\" class=\"attachment-1536x1536 size-1536x1536 wp-image-4444\" alt=\"Armoire g\u00e9n\u00e9rique de stockage d&#039;\u00e9nergie \u00e0 usage commercial, destin\u00e9e \u00e0 une installation en ext\u00e9rieur dans une zone de services industriels.\" srcset=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/outdoor-ci-energy-storage-cabinet.jpg 1254w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/outdoor-ci-energy-storage-cabinet-300x300.jpg 300w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/outdoor-ci-energy-storage-cabinet-1024x1024.jpg 1024w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/outdoor-ci-energy-storage-cabinet-150x150.jpg 150w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/outdoor-ci-energy-storage-cabinet-768x768.jpg 768w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/outdoor-ci-energy-storage-cabinet-600x600.jpg 600w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/outdoor-ci-energy-storage-cabinet-100x100.jpg 100w\" sizes=\"(max-width: 1254px) 100vw, 1254px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-de4ac97f auto-p elementor-widget elementor-widget-heading\" data-id=\"de4ac97f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\"><strong>La puissance nominale et la puissance de pointe c\u00f4t\u00e9 courant alternatif devraient constituer le premier crit\u00e8re de comparaison technique.<\/strong> Une proposition peut inclure une \u00e9nergie nominale en courant continu (CC) importante, mais ne pas pour autant permettre de prendre en charge la charge requise en usine si la conversion de puissance et la configuration c\u00f4t\u00e9 courant alternatif (CA) ne sont pas adapt\u00e9es aux conditions d'exploitation. L'inverse peut \u00e9galement se produire : une offre peut r\u00e9pondre aux exigences de puissance, mais ne pas fournir l'\u00e9nergie utilisable n\u00e9cessaire pendant la dur\u00e9e requise.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-bfb2e530 auto-p elementor-widget elementor-widget-heading\" data-id=\"bfb2e530\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">La demande de devis devrait pr\u00e9ciser le p\u00e9rim\u00e8tre de mesure de la puissance et de l\u2019\u00e9nergie. L\u2019acheteur devrait notamment indiquer si l\u2019exigence s\u2019applique aux bornes du PCS, \u00e0 un tableau basse tension ou \u00e0 un tableau d\u00e9fini pour les charges critiques. En pr\u00e9sentant l\u2019\u00e9nergie utilisable, les fournisseurs devraient indiquer comment leur offre tient compte de la consommation des auxiliaires, de la r\u00e9serve d\u2019\u00e9tat de charge, de la profondeur de d\u00e9charge, des pertes de conversion et des \u00e9ventuelles hypoth\u00e8ses de fin de vie.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-35fef6ac auto-p elementor-widget elementor-widget-heading\" data-id=\"35fef6ac\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Il ne s'agit pas l\u00e0 de d\u00e9tails commerciaux mineurs. Ce sont les hypoth\u00e8ses qui d\u00e9terminent si deux devis peuvent \u00eatre compar\u00e9s de mani\u00e8re \u00e9quitable. Si un fournisseur indique l'\u00e9nergie nominale de la batterie tandis qu'un autre fournit un chiffre correspondant \u00e0 l'\u00e9nergie utilisable c\u00f4t\u00e9 courant alternatif dans les conditions sp\u00e9cifi\u00e9es, l'acheteur ne doit pas consid\u00e9rer ces chiffres comme \u00e9quivalents.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-83a9ebfc auto-p elementor-widget elementor-widget-heading\" data-id=\"83a9ebfc\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Pour choisir un produit de sa gamme, MegSolid d\u00e9finit la puissance c\u00f4t\u00e9 courant alternatif \u00e0 partir de la charge et du mode de fonctionnement avant de comparer l\u2019\u00e9nergie des batteries. Elle valide ensuite l\u2019\u00e9nergie utilisable, la compatibilit\u00e9 des tensions, le r\u00e9gime de charge et de d\u00e9charge (C-rate), la temp\u00e9rature, l\u2019interface r\u00e9seau, le transformateur, les protections, le p\u00e9rim\u00e8tre des certificats et les responsabilit\u00e9s de l\u2019entreprise EPC locale. Le <strong><a href=\"https:\/\/www.solidess.com\/fr\/guide-sur-le-stockage-denergie-a-letat-solide-ci-2026\/\" target=\"_blank\" style=\"color:#61CE70\">Guide C&amp;I sur le stockage d'\u00e9nergie \u00e0 l'\u00e9tat solide<\/a><\/strong> est une ressource de MegSolid pour cadrer ces questions de projet.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-12f41e3f auto-h2 elementor-widget elementor-widget-heading\" data-id=\"12f41e3f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">D\u00e9finir le p\u00e9rim\u00e8tre associ\u00e9 \u00e0 l\u2019expression \u00ab syst\u00e8me de stockage d\u2019\u00e9nergie par batterie (BESS) OEM \u00bb<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-aaf611d9 auto-p elementor-widget elementor-widget-heading\" data-id=\"aaf611d9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">L'expression <strong>\u00ab syst\u00e8me de stockage d\u2019\u00e9nergie par batterie (BESS) OEM \u00bb<\/strong> ne d\u00e9finit pas \u00e0 elle seule le p\u00e9rim\u00e8tre de livraison. Elle peut d\u00e9signer un syst\u00e8me int\u00e9gr\u00e9 fourni dans le cadre d\u2019un accord commercial particulier, un syst\u00e8me configur\u00e9 pour une entreprise EPC ou un distributeur, ou la fourniture de sous-syst\u00e8mes qu\u2019un autre intervenant int\u00e9grera. L\u2019acheteur ne devrait pas pr\u00e9sumer que la mention OEM couvre toutes les obligations en mati\u00e8re de travaux \u00e9lectriques, de g\u00e9nie civil, de commande, de documentation ou d\u2019intervention sur site.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8f9360fe auto-p elementor-widget elementor-widget-heading\" data-id=\"8f9360fe\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">\u00c9tablissez une matrice du p\u00e9rim\u00e8tre qui identifie chaque livrable et le responsable correspondant. Elle devrait couvrir le syst\u00e8me de batteries, le BMS, le PCS, l\u2019EMS, le transformateur, l\u2019appareillage \u00e9lectrique, le comptage, les \u00e9quipements de communication, les interfaces de c\u00e2blage, les protections, les mat\u00e9riaux d\u2019installation, le g\u00e9nie civil, la mise en service, la formation, la garantie et le service. Si aucun responsable n\u2019est d\u00e9sign\u00e9 pour un \u00e9l\u00e9ment, traitez-le comme un risque non r\u00e9solu du projet, sans pr\u00e9sumer qu\u2019il est inclus.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6f335d8a auto-p elementor-widget elementor-widget-heading\" data-id=\"6f335d8a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default translation-block\">Consultez la page <a href=\"https:\/\/www.solidess.com\/fr\/a-propos-de-megsolid\/\" target=\"_blank\" style=\"color:#61CE70\">\u00c0 propos de MegSolid<\/a> pour comprendre les modalit\u00e9s de fourniture, puis transmettez le dossier technique de l\u2019usine par la page <a href=\"https:\/\/www.solidess.com\/fr\/contacter-megsolid\/\" target=\"_blank\" style=\"color:#61CE70\">Contacter MegSolid<\/a>. Demandez que l\u2019offre commerciale pr\u00e9cise les \u00e9quipements, la configuration, ainsi que le p\u00e9rim\u00e8tre de l\u2019int\u00e9gration et de l\u2019assistance. L\u2019acheteur pourra comparer une fourniture et une mise en \u0153uvre d\u00e9finies au lieu de s\u2019appuyer sur une pr\u00e9sentation g\u00e9n\u00e9rale de l\u2019entreprise.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-97d817d8 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"97d817d8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Adapter l'architecture du syst\u00e8me au site et aux contraintes \u00e9lectriques<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-527f1c47 auto-p elementor-widget elementor-widget-heading\" data-id=\"527f1c47\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Une armoire ext\u00e9rieure et un syst\u00e8me en conteneur constituent deux architectures de projet diff\u00e9rentes. Le choix de l'option appropri\u00e9e d\u00e9pend de la puissance requise et de la dur\u00e9e d'exploitation, de l'espace disponible, des restrictions d'acc\u00e8s, des conditions d'acc\u00e8s pour la maintenance, des interfaces \u00e9lectriques, de la disposition du transformateur et de l'appareillage de commutation, de la m\u00e9thode de refroidissement et de la r\u00e9partition des responsabilit\u00e9s au titre du contrat EPC. Pour faire un choix \u00e9clair\u00e9, il est n\u00e9cessaire de disposer des donn\u00e9es sp\u00e9cifiques au projet plut\u00f4t que de se fonder sur une pr\u00e9f\u00e9rence g\u00e9n\u00e9rique pour un type d'enceinte particulier.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5e7fdc00 auto-p elementor-widget elementor-widget-heading\" data-id=\"5e7fdc00\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default translation-block\">Les options de <a href=\"https:\/\/www.solidess.com\/fr\/systeme-de-stockage-denergie-pour-armoire-dexterieur-megsolid\/\" target=\"_blank\" style=\"color:#61CE70\">stockage d\u2019\u00e9nergie en armoire ext\u00e9rieure<\/a> et de <a href=\"https:\/\/www.solidess.com\/fr\/stockage-denergie-par-conteneur\/\" target=\"_blank\" style=\"color:#61CE70\">stockage d\u2019\u00e9nergie en conteneur<\/a> s\u2019appuient sur des ensembles d\u2019\u00e9quipements diff\u00e9rents pour un projet d\u2019usine. L\u2019ESSA0100B-0215 affiche des valeurs nominales de 100 kW et 215,04 kWh. L\u2019ESSC0500B-1075 affiche 500 kW et 1,0752 MWh, et l\u2019ESSC1000B-2150 affiche 1 MW et 2,1504 MWh. Comparez ces valeurs \u00e0 la puissance, \u00e0 la dur\u00e9e, \u00e0 l\u2019\u00e9nergie utilisable et aux conditions d\u2019acc\u00e8s r\u00e9ellement requises avant de choisir l\u2019architecture \u00e0 installer.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1ed29b0e auto-p elementor-widget elementor-widget-heading\" data-id=\"1ed29b0e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Donnez \u00e0 l\u2019\u00e9quipe technique une base de d\u00e9part pr\u00e9cise : <a href=\"https:\/\/www.solidess.com\/fr\/product\/systeme-de-stockage-denergie-en-armoire-exterieure\/\">ESSA0100B-0215<\/a> offre des valeurs nominales de 100 kW et 215,04 kWh, un refroidissement par air et une plage de fonctionnement de 0 \u00e0 45 \u00b0C ; <a href=\"https:\/\/www.solidess.com\/fr\/product\/stockage-denergie-solide-liquide-megasolide\/\">SolidESS 261kWh C&amp;I ESS<\/a> offre 261,24 kWh et 125 kVA, avec refroidissement liquide et r\u00e9duction de puissance au-del\u00e0 de 45 \u00b0C. Une cathode de chimie LFP peut coexister avec un \u00e9lectrolyte semi-solide. La nomenclature (BOM) de l\u2019offre identifie cette architecture. Le devis doit pr\u00e9ciser l\u2019\u00e9nergie utilisable c\u00f4t\u00e9 courant alternatif, le facteur de puissance, les limites environnementales et les obligations d\u2019int\u00e9gration pour l\u2019usine concern\u00e9e.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d508a2e elementor-tablet-align-center elementor-align-center auto-cta elementor-widget elementor-widget-button\" data-id=\"d508a2e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"#\" id=\"my_pdf\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Remplissez le formulaire de contact pour t\u00e9l\u00e9charger le PDF technique complet<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-42fab4ff auto-h2 elementor-widget elementor-widget-heading\" data-id=\"42fab4ff\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">V\u00e9rifier la compatibilit\u00e9 de la batterie, du PCS et des commandes avant de valider la nomenclature<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5c271ef9 auto-p elementor-widget elementor-widget-heading\" data-id=\"5c271ef9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\"><strong>La batterie et le PCS doivent \u00eatre \u00e9valu\u00e9s comme un seul syst\u00e8me en fonctionnement.<\/strong> Demandez au fournisseur d\u2019indiquer les mod\u00e8les exacts de la batterie et du PCS, leurs plages de fonctionnement compatibles, l\u2019architecture des protections, l\u2019interface de communication et le responsable des commandes du syst\u00e8me. La compatibilit\u00e9 devrait \u00eatre d\u00e9montr\u00e9e pour la configuration propos\u00e9e, au-del\u00e0 des informations g\u00e9n\u00e9rales des pages de cat\u00e9gorie ou des valeurs nominales.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3b0e5a56 auto-p elementor-widget elementor-widget-heading\" data-id=\"3b0e5a56\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Si un transformateur d\u2019isolement ou un dispositif de conversion d\u00e9di\u00e9 est propos\u00e9, il devrait figurer sur le sch\u00e9ma unifilaire et dans la nomenclature. MegSolid pr\u00e9sente une option qui repose sur un <strong><a href=\"https:\/\/www.solidess.com\/fr\/product\/systeme-de-conversion-denergie-megsolid\/\" target=\"_blank\" style=\"color:#61CE70\">syst\u00e8me de conversion de puissance avec transformateur d\u2019isolement<\/a><\/strong> . La conception du site doit \u00e9tablir, pour l\u2019usine concern\u00e9e, si cette solution est n\u00e9cessaire, incluse dans l\u2019offre ou adapt\u00e9e techniquement. L\u2019offre de projet doit le pr\u00e9ciser.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-505f8686 auto-p elementor-widget elementor-widget-heading\" data-id=\"505f8686\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Les commandes exigent le m\u00eame niveau de d\u00e9finition que le mat\u00e9riel. La proposition technique devrait d\u00e9crire les \u00e9tats de fonctionnement pr\u00e9vus, les sources de commande, les points de comptage, les alarmes, les interverrouillages et le responsable du d\u00e9lestage. Si l\u2019usine pr\u00e9voit une coordination avec le photovolta\u00efque, des groupes \u00e9lectrog\u00e8nes ou la gestion technique des b\u00e2timents existante, l\u2019examen de la conception devrait couvrir le p\u00e9rim\u00e8tre des communications et des commandes au lieu de laisser ce p\u00e9rim\u00e8tre \u00e0 l\u2019\u00e9tat d\u2019hypoth\u00e8se apr\u00e8s l\u2019attribution du contrat.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-691a0a74 auto-p elementor-widget elementor-widget-heading\" data-id=\"691a0a74\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default translation-block\">La page <strong><a href=\"https:\/\/www.solidess.com\/fr\/systemes-de-stockage-denergie-a-letat-solide\/\" target=\"_blank\" style=\"color:#61CE70\">Syst\u00e8mes de stockage d\u2019\u00e9nergie \u00e0 l\u2019\u00e9tat solide<\/a><\/strong> de MegSolid pr\u00e9sente cette cat\u00e9gorie de technologies du point de vue de l\u2019entreprise. Elle ne devrait pas se substituer \u00e0 une d\u00e9claration de compatibilit\u00e9 \u00e9lectrique propre au mod\u00e8le, \u00e0 un dossier de certification ou \u00e0 la description fonctionnelle de la commande du projet.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f5110453 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"f5110453\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Int\u00e9grer dans le contrat les exigences de conformit\u00e9 br\u00e9siliennes et le p\u00e9rim\u00e8tre local des travaux d'EPC<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ba87fb10 auto-p elementor-widget elementor-widget-heading\" data-id=\"ba87fb10\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\"><strong>La conformit\u00e9 aux exigences locales ne peut \u00eatre pr\u00e9sum\u00e9e sur la base d'une d\u00e9claration g\u00e9n\u00e9rale relative au produit ou d'une r\u00e9f\u00e9rence \u00e0 un certificat g\u00e9n\u00e9rique.<\/strong> Le propri\u00e9taire de l\u2019usine devrait communiquer \u00e0 l\u2019entreprise EPC locale et au fournisseur pressenti l\u2019emplacement pr\u00e9vu, les conditions du r\u00e9seau, les exigences applicables au site, la proc\u00e9dure d\u2019approbation et les contraintes de construction. L\u2019entreprise EPC locale devrait d\u00e9finir et documenter, dans le cadre de son contrat, les responsabilit\u00e9s propres au site pour les travaux \u00e9lectriques, le g\u00e9nie civil, les protections, la s\u00e9curit\u00e9, l\u2019installation et la mise en service.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8eb17811 auto-p elementor-widget elementor-widget-heading\" data-id=\"8eb17811\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Les certificats sont sp\u00e9cifiques \u00e0 un mod\u00e8le, \u00e0 une configuration et \u00e0 un march\u00e9. Avant de se fonder sur un certificat pour prendre une d\u00e9cision relative \u00e0 un appel d'offres, une homologation, une exp\u00e9dition ou une installation, il convient de se procurer le document correspondant et de v\u00e9rifier le num\u00e9ro de mod\u00e8le exact, la norme applicable, l'organisme \u00e9metteur, le num\u00e9ro de rapport, la dur\u00e9e de validit\u00e9 et les configurations couvertes. Une simple r\u00e9f\u00e9rence g\u00e9n\u00e9rale \u00e0 une certification ne doit pas \u00eatre consid\u00e9r\u00e9e comme la preuve qu'un syst\u00e8me propos\u00e9 r\u00e9pond aux exigences d'un site ou d'un march\u00e9.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a7b1a667 auto-p elementor-widget elementor-widget-heading\" data-id=\"a7b1a667\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Faites de la proc\u00e9dure d\u2019approbation et du programme des travaux sur site au Br\u00e9sil un livrable assorti d\u2019une \u00e9ch\u00e9ance. L\u2019entreprise EPC locale devrait d\u00e9finir les exigences r\u00e9elles du gestionnaire de r\u00e9seau et de l\u2019installation, ainsi que le calendrier de remise des documents. L\u2019offre de MegSolid devrait indiquer quels documents propres au mod\u00e8le fourni elle remettra et qui r\u00e9glera chaque interface encore ouverte avant l\u2019exp\u00e9dition et la mise en service sur site.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-70e1dac7 auto-p elementor-widget elementor-widget-heading\" data-id=\"70e1dac7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default translation-block\">Les <strong><a href=\"https:\/\/www.solidess.com\/fr\/bess\/cas-dapplication\/\" target=\"_blank\" style=\"color:#61CE70\">cas d\u2019application du stockage d\u2019\u00e9nergie<\/a><\/strong> de MegSolid peuvent \u00e9clairer le contexte d\u2019utilisation. Une r\u00e9f\u00e9rence ou une description de cas ne prouve toutefois pas que la conception \u00e9lectrique, les approbations, les hypoth\u00e8ses de fonctionnement ou les crit\u00e8res de r\u00e9ception d\u2019un autre projet s\u2019appliquent \u00e0 un nouveau site de production.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3e75d836 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"3e75d836\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Comparer les devis d\u2019apr\u00e8s les justificatifs, au-del\u00e0 de la capacit\u00e9 annonc\u00e9e<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7c59b7b6 auto-p elementor-widget elementor-widget-heading\" data-id=\"7c59b7b6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Un devis pour un syst\u00e8me de stockage d'\u00e9nergie C&amp;I n'est comparable que lorsque chaque fournisseur r\u00e9pond au m\u00eame cahier des charges technique. La comparaison doit normaliser le mod\u00e8le propos\u00e9, la puissance nominale en courant alternatif, les bases d'\u00e9nergie nominale et utilisable, les limites du syst\u00e8me, les hypoth\u00e8ses d'exploitation, le p\u00e9rim\u00e8tre d'int\u00e9gration, le plan d'essai, les conditions de garantie, les exclusions et les travaux requis sur site. Le prix ne doit \u00eatre \u00e9valu\u00e9 qu'une fois ces diff\u00e9rences mises en \u00e9vidence.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-63b7f490 auto-table elementor-widget elementor-widget-text-editor\" data-id=\"63b7f490\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"cea-table-wrap\"><table><tbody><\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2686b452 auto-p elementor-widget elementor-widget-heading\" data-id=\"2686b452\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Si une valeur ou une obligation influe sur la d\u00e9cision de l\u2019usine, exigez qu\u2019elle figure dans l\u2019offre et puisse \u00eatre rattach\u00e9e au mod\u00e8le retenu, \u00e0 la condition indiqu\u00e9e ou \u00e0 un livrable contractuel. Si le fournisseur ne peut pas encore donner l\u2019information, consignez-la comme un point ouvert, avec un responsable et une \u00e9ch\u00e9ance, plut\u00f4t que d\u2019en faire une hypoth\u00e8se implicite.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5077195b auto-h2 elementor-widget elementor-widget-heading\" data-id=\"5077195b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Utiliser les essais FAT et SAT pour v\u00e9rifier la configuration command\u00e9e<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-57e29540 auto-p elementor-widget elementor-widget-heading\" data-id=\"57e29540\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">L\u2019essai de r\u00e9ception en usine devrait v\u00e9rifier la configuration command\u00e9e selon un protocole approuv\u00e9. Une d\u00e9monstration g\u00e9n\u00e9rique du produit ne suffit pas. Le protocole devrait pr\u00e9ciser le mod\u00e8le et la configuration propos\u00e9s, les documents applicables, les v\u00e9rifications de fonctionnement et de protection, les points de communication, les alarmes, les \u00e9tats de commande et les preuves n\u00e9cessaires \u00e0 la remise de l\u2019installation. Toute exigence d\u00e9pendant du site devrait \u00eatre clairement attribu\u00e9e aux essais de r\u00e9ception sur site.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-379c7536 auto-p elementor-widget elementor-widget-heading\" data-id=\"379c7536\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">L\u2019essai de r\u00e9ception sur site devrait couvrir les interfaces propres \u00e0 l\u2019installation qui ne peuvent pas \u00eatre enti\u00e8rement v\u00e9rifi\u00e9es en usine. Selon le p\u00e9rim\u00e8tre du projet, il peut s\u2019agir du c\u00e2blage sur site, du comptage, des ordres de commande, de la coordination des protections, des communications et du p\u00e9rim\u00e8tre convenu des charges critiques. L\u2019entreprise EPC locale responsable et le fournisseur devraient convenir de qui dirige chaque essai, de qui y assiste, des donn\u00e9es \u00e0 consigner et des crit\u00e8res de r\u00e9ception.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-26b9a4e3 auto-p elementor-widget elementor-widget-heading\" data-id=\"26b9a4e3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Pour leurs premi\u00e8res recherches, les acheteurs peuvent consulter le <strong><a href=\"https:\/\/www.solidess.com\/fr\/ressource\/\" target=\"_blank\" style=\"color:#61CE70\">centre de ressources de MegSolid<\/a><\/strong> et <strong><a href=\"https:\/\/www.solidess.com\/fr\/bess\/actualites\/\" target=\"_blank\" style=\"color:#61CE70\">les actualit\u00e9s et analyses sur les BESS<\/a><\/strong>. Ces ressources ne remplacent pas les protocoles d'essai sign\u00e9s, la documentation sp\u00e9cifique aux mod\u00e8les ni le plan de mise en service du projet.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ea415bd7 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"ea415bd7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Envoyer une demande de devis qui permette une comparaison technique<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9e33b91c auto-p elementor-widget elementor-widget-heading\" data-id=\"9e33b91c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\"><strong>Une demande de devis compl\u00e8te permet d\u2019obtenir une r\u00e9ponse technique plus utile et de rep\u00e9rer t\u00f4t les lacunes aux interfaces.<\/strong> Transmettez le m\u00eame dossier d\u2019entr\u00e9e \u00e0 MegSolid, \u00e0 l\u2019entreprise EPC locale et aux autres fournisseurs pressentis. Exigez que chacun indique les hypoth\u00e8ses, les \u00e9carts, les exclusions et les informations encore n\u00e9cessaires \u00e0 la conception finale.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e91839d1 elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"e91839d1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Profil de charge de l'usine et planning des charges critiques.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Modes de fonctionnement requis et dur\u00e9e de l'alimentation de secours.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Sch\u00e9ma unifilaire, informations sur la tension disponible sur site et d\u00e9tails relatifs au transformateur.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Informations relatives aux installations photovolta\u00efques, aux groupes \u00e9lectrog\u00e8nes, au r\u00e9seau \u00e9lectrique et aux syst\u00e8mes de contr\u00f4le existants.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Surface disponible, emplacement d'installation, contraintes d'acc\u00e8s et conditions du site.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Autorisations locales requises, normes applicables et exigences en mati\u00e8re de documentation de conformit\u00e9.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">R\u00e9partition souhait\u00e9e des responsabilit\u00e9s pour la fourniture des \u00e9quipements, l\u2019installation, la mise en service, la formation, la garantie et le service.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Dispositions requises concernant le FAT, le SAT, la remise des documents et la pr\u00e9sence de t\u00e9moins lors de la r\u00e9ception.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e4530f5a auto-p elementor-widget elementor-widget-heading\" data-id=\"e4530f5a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Si une proposition nomme G-REIC ou une autre soci\u00e9t\u00e9 de projet, d\u00e9finissez son r\u00f4le contractuel r\u00e9el et son autorisation avant d'attribuer une responsabilit\u00e9 technique ou commerciale. Le nom d'une partie n'\u00e9tablit pas sa relation avec MegSolid ni avec le projet d'usine.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-640ba7d3 auto-p elementor-widget elementor-widget-heading\" data-id=\"640ba7d3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Un devis de batterie moins cher ne permet pas de maintenir une p\u00e9riode de production que le syst\u00e8me de stockage ne peut pas couvrir. Transmettez la charge mesur\u00e9e de l\u2019usine, les besoins en kW, kVA et heures, le sch\u00e9ma unifilaire, les conditions du site et les exigences documentaires locales par le <a href=\"https:\/\/www.solidess.com\/fr\/contacter-megsolid\/\" target=\"_blank\" style=\"color:#61CE70\">canal de contact de MegSolid<\/a>. Demandez \u00e0 MegSolid la configuration propos\u00e9e pour l\u2019armoire ou le conteneur et le PCS, les hypoth\u00e8ses d\u2019\u00e9nergie utilisable et de commande, le chiffrage du p\u00e9rim\u00e8tre respectif de la fourniture et de l\u2019entreprise EPC, les livrables FAT\/SAT, les \u00e9tapes de livraison et les modalit\u00e9s de garantie et d\u2019assistance. Ces \u00e9l\u00e9ments donnent \u00e0 l\u2019usine une offre comparable et \u00e0 l\u2019entreprise EPC un dossier pr\u00eat \u00e0 \u00eatre approuv\u00e9.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0da8102 elementor-tablet-align-center elementor-align-center auto-cta elementor-widget elementor-widget-button\" data-id=\"0da8102\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"#elementor-action%3Aaction%3Dpopup%3Aopen%26settings%3DeyJpZCI6Ijk0OCIsInRvZ2dsZSI6ZmFsc2V9\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Demander un devis pour le syst\u00e8me ESS \u00e0 l'\u00e9tat solide MegSolid<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-5e1951cc auto-faq e-flex e-con-boxed e-con e-child\" data-id=\"5e1951cc\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-1a0f863f elementor-widget elementor-widget-heading\" data-id=\"1a0f863f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">FAQ<\/h2>\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-87d6547f e-con-full e-flex e-con e-child\" data-id=\"87d6547f\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-851d30bd elementor-widget elementor-widget-n-accordion\" data-id=\"851d30bd\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;default_state&quot;:&quot;all_collapsed&quot;,&quot;max_items_expended&quot;:&quot;one&quot;,&quot;n_accordion_animation_duration&quot;:{&quot;unit&quot;:&quot;ms&quot;,&quot;size&quot;:400,&quot;sizes&quot;:[]}}\" data-widget_type=\"nested-accordion.default\">\n\t\t\t\t\t\t\t<div class=\"e-n-accordion\" aria-label=\"Accord\u00e9on. Ouvrez les liens \u00e0 l&#039;aide de la touche Entr\u00e9e ou de la barre d&#039;espace, fermez-les avec la touche \u00c9chap et naviguez \u00e0 l&#039;aide des touches fl\u00e9ch\u00e9es.\">\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2230\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"1\" tabindex=\"0\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2230\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Quel est le premier \u00e9l\u00e9ment \u00e0 dimensionner pour un syst\u00e8me de stockage d'\u00e9nergie C&amp;I ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2230\" class=\"elementor-element elementor-element-5b4c98ba e-con-full e-flex e-con e-child\" data-id=\"5b4c98ba\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2230\" class=\"elementor-element elementor-element-63e85dd0 e-con-full e-flex e-con e-child\" data-id=\"63e85dd0\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-1914bc8b elementor-widget elementor-widget-heading\" data-id=\"1914bc8b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Dimensionnez d\u2019abord la puissance nominale et la puissance de pointe c\u00f4t\u00e9 courant alternatif \u00e0 partir du profil de charge de l\u2019usine et du mode de fonctionnement pr\u00e9vu. D\u00e9finissez ensuite la dur\u00e9e requise et demandez sur quelle base l\u2019\u00e9nergie utilisable sera calcul\u00e9e au point de mesure convenu c\u00f4t\u00e9 courant alternatif.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2231\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"2\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2231\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Pourquoi la capacit\u00e9 nominale de la batterie en kWh ne suffit-elle pas pour comparer les offres de syst\u00e8mes de stockage d'\u00e9nergie par batterie (BESS) ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2231\" class=\"elementor-element elementor-element-b6e5b480 e-con-full e-flex e-con e-child\" data-id=\"b6e5b480\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2231\" class=\"elementor-element elementor-element-c35c16ad e-con-full e-flex e-con e-child\" data-id=\"c35c16ad\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-f4ceba37 elementor-widget elementor-widget-heading\" data-id=\"f4ceba37\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">La valeur nominale en kWh n\u2019\u00e9tablit ni la charge c\u00f4t\u00e9 courant alternatif que le syst\u00e8me peut alimenter, ni la base de calcul de l\u2019\u00e9nergie utilisable, ni la plage d\u2019\u00e9tat de charge (SOC), ni la profondeur de d\u00e9charge retenue, ni la consommation des auxiliaires, ni la prise en compte des pertes de conversion, ni les hypoth\u00e8ses de fin de vie. Les fournisseurs devraient d\u00e9clarer ces conditions de fa\u00e7on coh\u00e9rente.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2232\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"3\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2232\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Que signifie l\u2019expression \u00ab syst\u00e8me de stockage d\u2019\u00e9nergie par batterie (BESS) OEM \u00bb dans un achat ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2232\" class=\"elementor-element elementor-element-cb7dcd6c e-con-full e-flex e-con e-child\" data-id=\"cb7dcd6c\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2232\" class=\"elementor-element elementor-element-47144993 e-con-full e-flex e-con e-child\" data-id=\"47144993\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-9aaa67ba elementor-widget elementor-widget-heading\" data-id=\"9aaa67ba\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Cette expression peut d\u00e9signer diff\u00e9rentes modalit\u00e9s de fourniture, dont un syst\u00e8me int\u00e9gr\u00e9 ou des \u00e9quipements fournis pour une solution d\u2019une entreprise EPC ou d\u2019un distributeur. D\u00e9finissez la nomenclature, les responsabilit\u00e9s de conception, les essais, la mise en service, la garantie et les exclusions avant de vous appuyer sur l\u2019appellation OEM.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2233\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"4\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2233\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Une usine doit-elle opter pour une armoire d'ext\u00e9rieur ou un syst\u00e8me de stockage d'\u00e9nergie par batterie (BESS) en conteneur ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2233\" class=\"elementor-element elementor-element-381ce8b8 e-con-full e-flex e-con e-child\" data-id=\"381ce8b8\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2233\" class=\"elementor-element elementor-element-6a3e8566 e-con-full e-flex e-con e-child\" data-id=\"6a3e8566\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-02208975 elementor-widget elementor-widget-heading\" data-id=\"02208975\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Le choix d\u00e9pend de la puissance requise et de la dur\u00e9e d'utilisation, de l'encombrement, de l'acc\u00e8s au site, des interfaces \u00e9lectriques, de l'acc\u00e8s pour la maintenance, du mode de refroidissement et du p\u00e9rim\u00e8tre du contrat EPC. Une \u00e9tude sur site et un sch\u00e9ma unifilaire du projet doivent servir de base \u00e0 cette d\u00e9cision.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2234\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"5\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2234\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Quelles informations relatives au PCS un acheteur industriel doit-il demander ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2234\" class=\"elementor-element elementor-element-aa3d30ed e-con-full e-flex e-con e-child\" data-id=\"aa3d30ed\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2234\" class=\"elementor-element elementor-element-71b7045d e-con-full e-flex e-con e-child\" data-id=\"71b7045d\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-01993b98 elementor-widget elementor-widget-heading\" data-id=\"01993b98\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Demandez la r\u00e9f\u00e9rence exacte du PCS, les donn\u00e9es de r\u00e9f\u00e9rence pour la puissance c\u00f4t\u00e9 courant alternatif, la plage de fonctionnement c\u00f4t\u00e9 courant continu, les dispositifs de protection, la configuration du transformateur, l\u2019interface r\u00e9seau, les points de communication et la r\u00e9partition des responsabilit\u00e9s dans le syst\u00e8me. Confirmez la compatibilit\u00e9 avec la configuration de batterie propos\u00e9e.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2235\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"6\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2235\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Quelles informations faut-il fournir avant de demander un devis pour un BESS ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2235\" class=\"elementor-element elementor-element-ac7bc095 e-con-full e-flex e-con e-child\" data-id=\"ac7bc095\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2235\" class=\"elementor-element elementor-element-4a62e462 e-con-full e-flex e-con e-child\" data-id=\"4a62e462\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a70af5c7 elementor-widget elementor-widget-heading\" data-id=\"a70af5c7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Fournissez le profil de charge, la liste des charges critiques, la dur\u00e9e requise, les caract\u00e9ristiques du photovolta\u00efque et des groupes \u00e9lectrog\u00e8nes existants, le sch\u00e9ma unifilaire, les donn\u00e9es du transformateur, les conditions du site, la surface disponible et les documents de conformit\u00e9 requis. Les fournisseurs devraient traiter les donn\u00e9es manquantes comme des hypoth\u00e8ses restant \u00e0 confirmer.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2236\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"7\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2236\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Que doivent couvrir les essais de r\u00e9ception en usine d\u2019un BESS ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2236\" class=\"elementor-element elementor-element-9bf3b2dd e-con-full e-flex e-con e-child\" data-id=\"9bf3b2dd\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2236\" class=\"elementor-element elementor-element-6aaa78f3 e-con-full e-flex e-con e-child\" data-id=\"6aaa78f3\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-51422620 elementor-widget elementor-widget-heading\" data-id=\"51422620\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Les essais de r\u00e9ception en usine (FAT) devraient identifier la configuration command\u00e9e et v\u00e9rifier, selon un protocole approuv\u00e9, les \u00e9l\u00e9ments convenus en mati\u00e8re de fonctionnement, de protection, de communication, de documentation et de tra\u00e7abilit\u00e9. Les interfaces propres au site devraient relever des essais de r\u00e9ception sur site (SAT).<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2237\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"8\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2237\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Une d\u00e9claration g\u00e9n\u00e9rale relative \u00e0 la certification suffit-elle \u00e0 prouver la conformit\u00e9 d\u2019un projet au Br\u00e9sil ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2237\" class=\"elementor-element elementor-element-9453398f e-con-full e-flex e-con e-child\" data-id=\"9453398f\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2237\" class=\"elementor-element elementor-element-93290749 e-con-full e-flex e-con e-child\" data-id=\"93290749\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-df22b1ee elementor-widget elementor-widget-heading\" data-id=\"df22b1ee\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Non. Obtenez le certificat ou le rapport lui-m\u00eame et v\u00e9rifiez le mod\u00e8le et la configuration exacts, la norme, l\u2019organisme \u00e9metteur, le num\u00e9ro du rapport, la validit\u00e9 et la pertinence pour le march\u00e9 et l\u2019installation vis\u00e9s.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2238\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"9\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2238\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Quelles donn\u00e9es relatives au produit faut-il demander pour le syst\u00e8me MegSolid s\u00e9lectionn\u00e9 ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2238\" class=\"elementor-element elementor-element-3eedd490 e-con-full e-flex e-con e-child\" data-id=\"3eedd490\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2238\" class=\"elementor-element elementor-element-818ebcfe e-con-full e-flex e-con e-child\" data-id=\"818ebcfe\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-f195cc6b elementor-widget elementor-widget-heading\" data-id=\"f195cc6b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Demandez la fiche technique \u00e0 jour propre au mod\u00e8le, la description de la configuration, la nomenclature du devis, les certificats applicables, les conditions de garantie, les manuels, les informations sur les interfaces \u00e9lectriques et le p\u00e9rim\u00e8tre des essais FAT\/SAT. N\u2019utilisez pas les param\u00e8tres d\u2019un autre mod\u00e8le ou d\u2019une autre cat\u00e9gorie de produits.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2239\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"10\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2239\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Qui est responsable de l'int\u00e9gration du syst\u00e8me de stockage d'\u00e9nergie par batterie (BESS) dans une usine ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2239\" class=\"elementor-element elementor-element-75731c6f e-con-full e-flex e-con e-child\" data-id=\"75731c6f\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2239\" class=\"elementor-element elementor-element-75a6fa8c e-con-full e-flex e-con e-child\" data-id=\"75a6fa8c\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-582e28d3 elementor-widget elementor-widget-heading\" data-id=\"582e28d3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Le contrat doit attribuer les responsabilit\u00e9s. Le fournisseur, l\u2019entreprise EPC et le propri\u00e9taire du site devraient r\u00e9partir explicitement la fourniture des \u00e9quipements, les travaux de g\u00e9nie civil, l\u2019installation \u00e9lectrique, la coordination des protections, l\u2019int\u00e9gration des commandes, la mise en service, les approbations et l\u2019assistance apr\u00e8s-vente.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-22310\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"11\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-22310\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Existe-t-il un d\u00e9ploiement confirm\u00e9 du syst\u00e8me MegSolid BESS dans l'industrie manufacturi\u00e8re br\u00e9silienne ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-22310\" class=\"elementor-element elementor-element-f2d621da e-con-full e-flex e-con e-child\" data-id=\"f2d621da\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-22310\" class=\"elementor-element elementor-element-88d7ba07 e-con-full e-flex e-con e-child\" data-id=\"88d7ba07\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a09a56d4 elementor-widget elementor-widget-heading\" data-id=\"a09a56d4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Demandez des r\u00e9f\u00e9rences de projets approuv\u00e9es par le propri\u00e9taire qui correspondent au mode de fonctionnement, \u00e0 la configuration et \u00e0 l'environnement propos\u00e9s. V\u00e9rifiez ce qui a \u00e9t\u00e9 fourni, mesur\u00e9 et accept\u00e9 avant d'utiliser une autre installation pour justifier la conception de cette usine ; aucune r\u00e9f\u00e9rence br\u00e9silienne sp\u00e9cifique n'est \u00e9tablie dans cette revue.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-22311\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"12\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-22311\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Quels \u00e9l\u00e9ments un fabricant br\u00e9silien doit-il v\u00e9rifier aupr\u00e8s de son EPC local avant de commander un syst\u00e8me de stockage d'\u00e9nergie par batterie (BESS) ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-22311\" class=\"elementor-element elementor-element-f9ccba6c e-con-full e-flex e-con e-child\" data-id=\"f9ccba6c\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-22311\" class=\"elementor-element elementor-element-72bd97ba e-con-full e-flex e-con e-child\" data-id=\"72bd97ba\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-cf6ad336 elementor-widget elementor-widget-heading\" data-id=\"cf6ad336\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Confirmez la conception \u00e9lectrique du site, les obligations aux interfaces du r\u00e9seau, les exigences applicables, la proc\u00e9dure d\u2019approbation, la m\u00e9thode d\u2019installation, la coordination des protections, le plan de mise en service et les responsabilit\u00e9s de r\u00e9ception. Ces \u00e9l\u00e9ments sont propres au site et ne peuvent pas \u00eatre d\u00e9duits d\u2019une page produit.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-22312\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"13\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-22312\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> G-REIC Energy Real Estate R.E.I.C. est-elle li\u00e9e \u00e0 MegSolid ou \u00e0 cette pr\u00e9sentation pour pr\u00e9parer l\u2019achat ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-22312\" class=\"elementor-element elementor-element-5b4620de e-con-full e-flex e-con e-child\" data-id=\"5b4620de\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-22312\" class=\"elementor-element elementor-element-82f98ed8 e-con-full e-flex e-con e-child\" data-id=\"82f98ed8\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-f0f69e4c elementor-widget elementor-widget-heading\" data-id=\"f0f69e4c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Aucune affiliation de G-REIC \u00e0 MegSolid ni aucun r\u00f4le dans le projet ne sont v\u00e9rifi\u00e9s ici. Demandez \u00e0 la partie contractante de pr\u00e9ciser sa responsabilit\u00e9 r\u00e9elle et son habilitation avant de la consid\u00e9rer comme un fournisseur, une autorit\u00e9 d\u2019approbation ou un partenaire du projet.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-22313\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"14\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-22313\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Quelles responsabilit\u00e9s d'approvisionnement un devis BESS OEM doit-il rendre explicites ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-22313\" class=\"elementor-element elementor-element-0f7c4ec1 e-con-full e-flex e-con e-child\" data-id=\"0f7c4ec1\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-22313\" class=\"elementor-element elementor-element-eeba49fe e-con-full e-flex e-con e-child\" data-id=\"eeba49fe\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-114a5520 elementor-widget elementor-widget-heading\" data-id=\"114a5520\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Cette expression peut d\u00e9signer diff\u00e9rentes modalit\u00e9s de fourniture, dont un syst\u00e8me int\u00e9gr\u00e9 ou des \u00e9quipements fournis pour une solution d\u2019une entreprise EPC ou d\u2019un distributeur. D\u00e9finissez la nomenclature, les responsabilit\u00e9s de conception, les essais, la mise en service, la garantie et les exclusions avant de vous appuyer sur l\u2019appellation OEM.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-22314\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"15\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-22314\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Comment les acheteurs br\u00e9siliens doivent-ils v\u00e9rifier le certificat joint \u00e0 une offre BESS ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-22314\" class=\"elementor-element elementor-element-6389ebc1 e-con-full e-flex e-con e-child\" data-id=\"6389ebc1\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-22314\" class=\"elementor-element elementor-element-c6249961 e-con-full e-flex e-con e-child\" data-id=\"c6249961\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-b91520c1 elementor-widget elementor-widget-heading\" data-id=\"b91520c1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Non. Obtenez le certificat ou le rapport lui-m\u00eame et v\u00e9rifiez le mod\u00e8le et la configuration exacts, la norme, l\u2019organisme \u00e9metteur, le num\u00e9ro du rapport, la validit\u00e9 et la pertinence pour le march\u00e9 et l\u2019installation vis\u00e9s.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-22315\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"16\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-22315\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Quelles responsabilit\u00e9s de site et de r\u00e9ception doivent \u00eatre convenues avant une commande BESS au Br\u00e9sil ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-22315\" class=\"elementor-element elementor-element-396574ec e-con-full e-flex e-con e-child\" data-id=\"396574ec\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-22315\" class=\"elementor-element elementor-element-c54741f0 e-con-full e-flex e-con e-child\" data-id=\"c54741f0\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-14d9a683 elementor-widget elementor-widget-heading\" data-id=\"14d9a683\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Confirmez la conception \u00e9lectrique du site, les obligations aux interfaces du r\u00e9seau, les exigences applicables, la proc\u00e9dure d\u2019approbation, la m\u00e9thode d\u2019installation, la coordination des protections, le plan de mise en service et les responsabilit\u00e9s de r\u00e9ception. Ces \u00e9l\u00e9ments sont propres au site et ne peuvent pas \u00eatre d\u00e9duits d\u2019une page produit.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Comparez les offres de syst\u00e8mes de stockage d'\u00e9nergie par batterie (BESS) propos\u00e9s par les \u00e9quipementiers aux usines br\u00e9siliennes en fonction de la puissance en courant alternatif, de l'\u00e9nergie utilisable, de l'\u00e9tendue de la fourniture\/du contrat EPC et des responsabilit\u00e9s li\u00e9es aux tests FAT\/SAT. Envoyez \u00e0 MegSolid la charge de votre usine et votre cahier des charges techniques pour obtenir une proposition adapt\u00e9e \u00e0 votre mod\u00e8le, un devis, les modalit\u00e9s de livraison et l'\u00e9tendue de l'assistance.<\/p>","protected":false},"author":4,"featured_media":4446,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"_joinchat":[],"footnotes":""},"categories":[1,713],"tags":[197,195,31,198,196],"class_list":["post-4445","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-bess","category-bess-procurement-economics","tag-bess-acceptance-testing","tag-brazilian-factory-bess","tag-ci-energy-storage","tag-epc-scope-management","tag-oem-bess-procurement"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/posts\/4445","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/comments?post=4445"}],"version-history":[{"count":11,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/posts\/4445\/revisions"}],"predecessor-version":[{"id":8191,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/posts\/4445\/revisions\/8191"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/media\/4446"}],"wp:attachment":[{"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/media?parent=4445"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/categories?post=4445"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/tags?post=4445"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}