{"id":4445,"date":"2026-08-03T16:58:34","date_gmt":"2026-08-03T08:58:34","guid":{"rendered":"https:\/\/www.solidess.com\/?p=4445"},"modified":"2026-10-08T17:59:34","modified_gmt":"2026-10-08T09:59:34","slug":"comment-evaluer-un-systeme-de-stockage-denergie-par-batterie-bess-dun-equipementier-oem-pour-les-usines-bresiliennes","status":"publish","type":"post","link":"https:\/\/www.solidess.com\/fr\/how-to-evaluate-an-oem-battery-energy-storage-system-bess-for-brazilian-factories\/","title":{"rendered":"Comment \u00e9valuer un syst\u00e8me de stockage d'\u00e9nergie par batterie (BESS) d'origine pour les usines br\u00e9siliennes"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"4445\" class=\"elementor elementor-4445\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-bf4793c e-con-full auto-article-root e-flex e-con e-parent\" data-id=\"bf4793c\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-2032ed01 auto-p elementor-widget elementor-widget-heading\" data-id=\"2032ed01\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\"><strong>En ce qui concerne les syst\u00e8mes de stockage d'\u00e9nergie par batterie (BESS) dans l'industrie manufacturi\u00e8re br\u00e9silienne, il convient de commencer par d\u00e9terminer la charge mesur\u00e9e de l'usine, la puissance CA requise, le mode de fonctionnement et le p\u00e9rim\u00e8tre de mise en \u0153uvre local avant de comparer la capacit\u00e9 ou le prix des batteries.<\/strong> MegSolid propose des solutions de stockage d'\u00e9nergie \u00e0 usage commercial et industriel, des \u00e9quipements de conversion d'\u00e9nergie, ainsi qu'une technologie hybride de stockage d'\u00e9nergie \u00e0 l'\u00e9tat solide. Toutefois, un projet d'usine ne doit \u00eatre lanc\u00e9 que lorsque la configuration choisie, la nomenclature contractuelle (BOM), les exigences d'essai et les responsabilit\u00e9s locales de l'EPC ont \u00e9t\u00e9 formalis\u00e9es pour le site concern\u00e9.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3810785c elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"3810785c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>D\u00e9finissez les charges critiques et le mode de fonctionnement requis avant de lancer un appel d'offres.<\/strong><\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>S\u00e9lectionnez la puissance alternative nominale et la puissance de cr\u00eate avant de comparer l'\u00e9nergie nominale de la batterie.<\/strong><\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>Attribuer les responsabilit\u00e9s relatives aux syst\u00e8mes de contr\u00f4le et de commande (PCS), aux dispositifs de contr\u00f4le, aux transformateurs, aux appareillages de commutation, \u00e0 l'installation et \u00e0 la mise en service.<\/strong><\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>Demandez les documents sp\u00e9cifiques au mod\u00e8le, les certificats, les conditions de garantie et les justificatifs des tests FAT\/SAT avant de valider le bon de commande.<\/strong><\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-60106d08 auto-p elementor-widget elementor-widget-heading\" data-id=\"60106d08\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Il s'agit d'un cadre d'approvisionnement fond\u00e9 sur des donn\u00e9es factuelles destin\u00e9 aux propri\u00e9taires d'installations industrielles, aux ma\u00eetres d'\u0153uvre EPC, aux distributeurs et aux \u00e9quipes d'ing\u00e9nierie. Il ne s'agit pas d'une conception \u00e9lectrique br\u00e9silienne, d'une \u00e9valuation tarifaire, d'une autorisation de raccordement ni d'un avis r\u00e9glementaire. Les informations relatives aux exigences des services publics br\u00e9siliens, aux proc\u00e9dures d'autorisation locales, \u00e0 l'acceptation des certificats et aux normes d'installation sp\u00e9cifiques au site ne sont pas disponibles dans les fichiers sources actuels de MegSolid et doivent \u00eatre confirm\u00e9es pour l'installation effective par le ma\u00eetre d'\u0153uvre local (EPC), le service public concern\u00e9 et les parties prenantes du projet.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9368a056 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"9368a056\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">D\u00e9finissez le probl\u00e8me de fabrication avant de demander un devis BESS<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7928716c auto-image elementor-widget elementor-widget-image\" data-id=\"7928716c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"1254\" height=\"1254\" src=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/oem-bess-system-scope.jpg\" class=\"attachment-1536x1536 size-1536x1536 wp-image-4443\" alt=\"Sch\u00e9ma illustrant les interfaces de stockage par batterie entre une usine, un syst\u00e8me de conversion d&#039;\u00e9nergie, le r\u00e9seau \u00e9lectrique, une installation solaire et un groupe \u00e9lectrog\u00e8ne.\" srcset=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/oem-bess-system-scope.jpg 1254w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/oem-bess-system-scope-300x300.jpg 300w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/oem-bess-system-scope-1024x1024.jpg 1024w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/oem-bess-system-scope-150x150.jpg 150w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/oem-bess-system-scope-768x768.jpg 768w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/oem-bess-system-scope-600x600.jpg 600w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/oem-bess-system-scope-100x100.jpg 100w\" sizes=\"(max-width: 1254px) 100vw, 1254px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-59e08f9 elementor-tablet-align-center elementor-align-center auto-cta elementor-widget elementor-widget-button\" data-id=\"59e08f9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"#elementor-action%3Aaction%3Dpopup%3Aopen%26settings%3DeyJpZCI6Ijk0OCIsInRvZ2dsZSI6ZmFsc2V9\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Obtenez d\u00e8s maintenant votre solution sur mesure de stockage d'\u00e9nergie C&amp;I<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-97093b22 auto-p elementor-widget elementor-widget-heading\" data-id=\"97093b22\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Un syst\u00e8me de stockage d'\u00e9nergie par batterie peut \u00eatre envisag\u00e9 pour plusieurs objectifs d'exploitation, notamment le soutien de certaines charges, la coordination avec la production sur site, la coordination avec les groupes \u00e9lectrog\u00e8nes ou une strat\u00e9gie planifi\u00e9e de gestion de la charge. Ces objectifs ne sont pas interchangeables. Chacun d'entre eux modifie la puissance et l'\u00e9nergie requises, les commandes, les dispositifs de protection et les crit\u00e8res d'acceptation du site.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-84a00013 auto-p elementor-widget elementor-widget-heading\" data-id=\"84a00013\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Avant de contacter un fabricant ou un \u00e9quipementier de syst\u00e8mes de stockage d'\u00e9nergie par batterie (BESS), il convient de r\u00e9partir la charge de l'installation en groupes d'exploitation bien distincts. L'\u00e9quipe charg\u00e9e du projet doit identifier les charges qui doivent rester aliment\u00e9es, celles qui peuvent fonctionner pendant une p\u00e9riode d\u00e9finie et celles qui peuvent \u00eatre coup\u00e9es ou reprogramm\u00e9es. Cette classification \u00e9tablit une d\u00e9limitation \u00e9lectrique concr\u00e8te et \u00e9vite qu'un devis ne soit \u00e9valu\u00e9 uniquement sur la base d'un chiffre nominal en kWh.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8e0e98df auto-p elementor-widget elementor-widget-heading\" data-id=\"8e0e98df\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">La premi\u00e8re demande de donn\u00e9es doit porter sur le meilleur profil de charge de l'usine disponible, de pr\u00e9f\u00e9rence \u00e0 des intervalles de 15 ou 30 minutes, ainsi que sur les pics de courte dur\u00e9e connus et les changements de processus pr\u00e9vus. Un simple chiffre de consommation mensuel ne permet pas de d\u00e9terminer le profil de puissance requis par un syst\u00e8me de stockage d\u2019\u00e9nergie C&amp;I. L\u2019acheteur doit \u00e9galement pr\u00e9ciser si le syst\u00e8me envisag\u00e9 est destin\u00e9 \u00e0 fonctionner avec le r\u00e9seau, une installation photovolta\u00efque, un g\u00e9n\u00e9rateur, un contr\u00f4leur de micro-r\u00e9seau ou un panneau de charges critiques d\u00e9fini.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-faf3e61b auto-p elementor-widget elementor-widget-heading\" data-id=\"faf3e61b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">MegSolid <strong><a href=\"https:\/\/www.solidess.com\/fr\/bess\/\" target=\"_blank\" style=\"color:#61CE70\">P\u00f4le de solutions BESS<\/a><\/strong> constitue un point de d\u00e9part pour passer en revue les diff\u00e9rentes cat\u00e9gories de syst\u00e8mes de stockage d'\u00e9nergie de l'entreprise. Les informations relatives \u00e0 ces cat\u00e9gories peuvent faciliter les premi\u00e8res discussions, mais elles ne sauraient se substituer \u00e0 une \u00e9tude sur site, \u00e0 un sch\u00e9ma unifilaire, \u00e0 une \u00e9tude de charge ou \u00e0 une analyse de conception sp\u00e9cifique au projet.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-91e599fa auto-table elementor-widget elementor-widget-text-editor\" data-id=\"91e599fa\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"cea-table-wrap\"><table><tbody><\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5bec4c5a auto-h2 elementor-widget elementor-widget-heading\" data-id=\"5bec4c5a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Optez pour l'alimentation secteur avant de comparer l'\u00e9nergie fournie par la batterie<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-593d357c auto-image elementor-widget elementor-widget-image\" data-id=\"593d357c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"1254\" height=\"1254\" src=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/outdoor-ci-energy-storage-cabinet.jpg\" class=\"attachment-1536x1536 size-1536x1536 wp-image-4444\" alt=\"Armoire g\u00e9n\u00e9rique de stockage d&#039;\u00e9nergie \u00e0 usage commercial, destin\u00e9e \u00e0 une installation en ext\u00e9rieur dans une zone de services industriels.\" srcset=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/outdoor-ci-energy-storage-cabinet.jpg 1254w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/outdoor-ci-energy-storage-cabinet-300x300.jpg 300w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/outdoor-ci-energy-storage-cabinet-1024x1024.jpg 1024w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/outdoor-ci-energy-storage-cabinet-150x150.jpg 150w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/outdoor-ci-energy-storage-cabinet-768x768.jpg 768w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/outdoor-ci-energy-storage-cabinet-600x600.jpg 600w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/outdoor-ci-energy-storage-cabinet-100x100.jpg 100w\" sizes=\"(max-width: 1254px) 100vw, 1254px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-de4ac97f auto-p elementor-widget elementor-widget-heading\" data-id=\"de4ac97f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\"><strong>La puissance nominale et la puissance de cr\u00eate en courant alternatif doivent constituer le premier crit\u00e8re de comparaison technique.<\/strong> Une proposition peut inclure une \u00e9nergie nominale en courant continu (CC) importante, mais ne pas pour autant permettre de prendre en charge la charge requise en usine si la conversion de puissance et la configuration c\u00f4t\u00e9 courant alternatif (CA) ne sont pas adapt\u00e9es aux conditions d'exploitation. L'inverse peut \u00e9galement se produire : une offre peut r\u00e9pondre aux exigences de puissance, mais ne pas fournir l'\u00e9nergie utilisable n\u00e9cessaire pendant la dur\u00e9e requise.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-bfb2e530 auto-p elementor-widget elementor-widget-heading\" data-id=\"bfb2e530\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">L'appel d'offres doit pr\u00e9ciser les limites de mesure tant pour la puissance que pour l'\u00e9nergie. Par exemple, l\u2019acheteur doit pr\u00e9ciser si l\u2019exigence s\u2019applique aux bornes du PCS, \u00e0 un tableau basse tension ou \u00e0 un panneau de charge critique d\u00e9fini. Les fournisseurs doivent ensuite indiquer, lorsqu\u2019ils pr\u00e9sentent les informations relatives \u00e0 l\u2019\u00e9nergie utilisable, comment leur proposition prend en compte la consommation auxiliaire, l\u2019\u00e9tat de charge de r\u00e9serve, la profondeur de d\u00e9charge, les pertes de conversion et toute hypoth\u00e8se relative \u00e0 la fin de vie.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-35fef6ac auto-p elementor-widget elementor-widget-heading\" data-id=\"35fef6ac\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Il ne s'agit pas l\u00e0 de d\u00e9tails commerciaux mineurs. Ce sont les hypoth\u00e8ses qui d\u00e9terminent si deux devis peuvent \u00eatre compar\u00e9s de mani\u00e8re \u00e9quitable. Si un fournisseur indique l'\u00e9nergie nominale de la batterie tandis qu'un autre fournit un chiffre correspondant \u00e0 l'\u00e9nergie utilisable c\u00f4t\u00e9 courant alternatif dans les conditions sp\u00e9cifi\u00e9es, l'acheteur ne doit pas consid\u00e9rer ces chiffres comme \u00e9quivalents.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-83a9ebfc auto-p elementor-widget elementor-widget-heading\" data-id=\"83a9ebfc\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Le principe de s\u00e9lection de la gamme de produits MegSolid consiste \u00e0 d\u00e9terminer l'alimentation en courant alternatif en fonction de la charge et du mode de fonctionnement avant de comparer l'\u00e9nergie des batteries, puis \u00e0 valider l'\u00e9nergie utilisable, la compatibilit\u00e9 de tension, le taux de d\u00e9charge (C-rate), la temp\u00e9rature, l'interface avec le r\u00e9seau, le transformateur, la protection, le champ d'application des certificats et la responsabilit\u00e9 locale de l'EPC. Le <strong><a href=\"https:\/\/www.solidess.com\/fr\/guide-sur-le-stockage-denergie-a-letat-solide-ci-2026\/\" target=\"_blank\" style=\"color:#61CE70\">Guide C&amp;I sur le stockage d'\u00e9nergie \u00e0 semi-conducteurs<\/a><\/strong> constitue une ressource utile au sein de l'entreprise pour d\u00e9finir ces questions relatives au projet.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-12f41e3f auto-h2 elementor-widget elementor-widget-heading\" data-id=\"12f41e3f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Consid\u00e9rer le \u201c syst\u00e8me de stockage d\u2019\u00e9nergie par batterie OEM (BESS) \u201d comme une d\u00e9cision relative au champ d\u2019application<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-aaf611d9 auto-p elementor-widget elementor-widget-heading\" data-id=\"aaf611d9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">L'expression <strong>Syst\u00e8me de stockage d'\u00e9nergie par batterie (BESS) d'origine (OEM)<\/strong> ne d\u00e9finit pas, en soi, le p\u00e9rim\u00e8tre de la livraison. Il peut s'agir d'un syst\u00e8me int\u00e9gr\u00e9 fourni dans le cadre d'un accord commercial particulier, d'un syst\u00e8me configur\u00e9 pour un ma\u00eetre d'\u0153uvre (EPC) ou un distributeur, ou encore de la fourniture de sous-syst\u00e8mes qu'une autre partie se chargera d'int\u00e9grer. L'acheteur ne doit pas partir du principe que la mention \u00ab OEM \u00bb englobe l'ensemble des obligations en mati\u00e8re d'\u00e9lectricit\u00e9, de g\u00e9nie civil, de contr\u00f4le-commande, de documentation ou de service apr\u00e8s-vente.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8f9360fe auto-p elementor-widget elementor-widget-heading\" data-id=\"8f9360fe\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">\u00c9laborez plut\u00f4t une matrice de p\u00e9rim\u00e8tre qui identifie chaque livrable et la personne qui en est responsable. Cette matrice doit couvrir le syst\u00e8me de batterie, le BMS, le PCS, l\u2019EMS, le transformateur, l\u2019appareillage de commutation, les compteurs, les \u00e9quipements de communication, les interfaces de c\u00e2blage, les \u00e9quipements de protection, les mat\u00e9riaux d\u2019installation, les travaux de g\u00e9nie civil, la mise en service, la formation, la garantie et le service apr\u00e8s-vente. Lorsqu\u2019un \u00e9l\u00e9ment n\u2019a pas de responsable d\u00e9sign\u00e9, consid\u00e9rez-le comme un risque de projet non r\u00e9solu plut\u00f4t que comme un \u00e9l\u00e9ment implicitement inclus.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6f335d8a auto-p elementor-widget elementor-widget-heading\" data-id=\"6f335d8a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">MegSolid pr\u00e9cise qu\u2019elle se concentre sur l\u2019exploitation et la commercialisation \u00e0 l\u2019\u00e9chelle mondiale de syst\u00e8mes de stockage d\u2019\u00e9nergie destin\u00e9s aux secteurs r\u00e9sidentiel, commercial et industriel, aux micro-r\u00e9seaux et aux grandes installations, gr\u00e2ce \u00e0 sa technologie hybride de batteries \u00e0 l\u2019\u00e9tat solide. Il s\u2019agit l\u00e0 d\u2019un positionnement de l\u2019entreprise et non d\u2019une preuve qu\u2019une configuration de projet particuli\u00e8re est incluse dans un devis. Les acheteurs peuvent consulter <strong><a href=\"https:\/\/www.solidess.com\/fr\/a-propos-de-megsolid\/\" target=\"_blank\" style=\"color:#61CE70\">\u00c0 propos de MegSolid<\/a><\/strong> et utiliser <strong><a href=\"https:\/\/www.solidess.com\/fr\/contacter-megsolid\/\" target=\"_blank\" style=\"color:#61CE70\">Contacter MegSolid<\/a><\/strong> pour soumettre un dossier technique concernant un projet s\u00e9lectionn\u00e9.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-97d817d8 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"97d817d8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Adapter l'architecture du syst\u00e8me au site et aux contraintes \u00e9lectriques<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-527f1c47 auto-p elementor-widget elementor-widget-heading\" data-id=\"527f1c47\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Une armoire ext\u00e9rieure et un syst\u00e8me en conteneur constituent deux architectures de projet diff\u00e9rentes. Le choix de l'option appropri\u00e9e d\u00e9pend de la puissance requise et de la dur\u00e9e d'exploitation, de l'espace disponible, des restrictions d'acc\u00e8s, des conditions d'acc\u00e8s pour la maintenance, des interfaces \u00e9lectriques, de la disposition du transformateur et de l'appareillage de commutation, de la m\u00e9thode de refroidissement et de la r\u00e9partition des responsabilit\u00e9s au titre du contrat EPC. Pour faire un choix \u00e9clair\u00e9, il est n\u00e9cessaire de disposer des donn\u00e9es sp\u00e9cifiques au projet plut\u00f4t que de se fonder sur une pr\u00e9f\u00e9rence g\u00e9n\u00e9rique pour un type d'enceinte particulier.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5e7fdc00 auto-p elementor-widget elementor-widget-heading\" data-id=\"5e7fdc00\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">MegSolid r\u00e9pertorie \u00e0 la fois un <strong><a href=\"https:\/\/www.solidess.com\/fr\/systeme-de-stockage-denergie-pour-armoire-dexterieur-megsolid\/\" target=\"_blank\" style=\"color:#61CE70\">Syst\u00e8me de stockage d'\u00e9nergie en armoire ext\u00e9rieure<\/a><\/strong> et un <strong><a href=\"https:\/\/www.solidess.com\/fr\/stockage-denergie-par-conteneur\/\" target=\"_blank\" style=\"color:#61CE70\">Syst\u00e8me de stockage d'\u00e9nergie en conteneur<\/a><\/strong> parmi ses cat\u00e9gories C&amp;I. Leur mention ne garantit pas leur ad\u00e9quation \u00e0 une usine br\u00e9silienne sp\u00e9cifique. La proposition doit pr\u00e9ciser le mod\u00e8le exact propos\u00e9, sa configuration, les exigences d'acc\u00e8s, les interfaces \u00e9lectriques, la responsabilit\u00e9 relative aux fondations ou au montage, ainsi que les limites entre le p\u00e9rim\u00e8tre du fournisseur et celui de l'EPC.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1ed29b0e auto-p elementor-widget elementor-widget-heading\" data-id=\"1ed29b0e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Ne transf\u00e9rez pas les sp\u00e9cifications d\u2019un composant, d\u2019une famille de produits ou d\u2019un autre syst\u00e8me dans la configuration s\u00e9lectionn\u00e9e. En particulier, la documentation MegSolid actuellement fournie pour cette pr\u00e9sentation ne comprend pas de fiche technique sp\u00e9cifique \u00e0 un mod\u00e8le permettant d\u2019utiliser la capacit\u00e9 d\u2019un syst\u00e8me de stockage d\u2019\u00e9nergie, la puissance CA, la m\u00e9thode de refroidissement, la description des cellules de batterie ou le rendement dans le cadre d\u2019une proposition d\u2019usine. Demandez la fiche technique et la nomenclature de devis actuelles du mod\u00e8le s\u00e9lectionn\u00e9 avant d\u2019utiliser tout param\u00e8tre produit dans un appel d\u2019offres, une comparaison technique, un contrat ou un test de r\u00e9ception.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d508a2e elementor-tablet-align-center elementor-align-center auto-cta elementor-widget elementor-widget-button\" data-id=\"d508a2e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"#\" id=\"my_pdf\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Remplissez le formulaire de contact pour t\u00e9l\u00e9charger le PDF technique complet<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-42fab4ff auto-h2 elementor-widget elementor-widget-heading\" data-id=\"42fab4ff\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">V\u00e9rifier la compatibilit\u00e9 de la batterie, du PCS et des commandes avant de valider la nomenclature<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5c271ef9 auto-p elementor-widget elementor-widget-heading\" data-id=\"5c271ef9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\"><strong>La batterie et le PCS doivent \u00eatre consid\u00e9r\u00e9s comme un seul et m\u00eame syst\u00e8me d'exploitation.<\/strong> Demandez au fournisseur d'indiquer les mod\u00e8les exacts de la batterie et du PCS, leurs plages de fonctionnement compatibles, les dispositifs de protection, l'interface de communication et la r\u00e9partition des responsabilit\u00e9s en mati\u00e8re de contr\u00f4le du syst\u00e8me. La compatibilit\u00e9 doit \u00eatre d\u00e9montr\u00e9e pour la configuration propos\u00e9e, et non d\u00e9duite \u00e0 partir de pages de cat\u00e9gories g\u00e9n\u00e9rales ou de valeurs nominales.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3b0e5a56 auto-p elementor-widget elementor-widget-heading\" data-id=\"3b0e5a56\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Lorsqu'un transformateur d'isolement ou un dispositif de conversion d\u00e9di\u00e9 est propos\u00e9, il doit \u00eatre repr\u00e9sent\u00e9 sur le sch\u00e9ma unifilaire et identifi\u00e9 dans la nomenclature. MegSolid a publi\u00e9 un <strong><a href=\"https:\/\/www.solidess.com\/fr\/product\/systeme-de-conversion-denergie-megsolid\/\" target=\"_blank\" style=\"color:#61CE70\">Syst\u00e8me de conversion de puissance avec transformateur d'isolement<\/a><\/strong> trajet. Il convient de d\u00e9terminer, lors de la conception du site, si cela est n\u00e9cessaire, pr\u00e9vu ou techniquement appropri\u00e9 pour une usine donn\u00e9e, et de le pr\u00e9ciser dans l'offre de projet.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-505f8686 auto-p elementor-widget elementor-widget-heading\" data-id=\"505f8686\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Les commandes doivent \u00eatre d\u00e9finies avec le m\u00eame niveau de pr\u00e9cision que le mat\u00e9riel. La proposition technique doit d\u00e9crire les \u00e9tats de fonctionnement pr\u00e9vus, les sources de commande, les points de mesure, les alarmes, les verrouillages et la responsabilit\u00e9 en mati\u00e8re de d\u00e9lestage. Si l\u2019usine pr\u00e9voit une coordination avec des installations photovolta\u00efques, des g\u00e9n\u00e9rateurs ou des syst\u00e8mes de gestion technique des b\u00e2timents existants, les limites des communications et des commandes doivent \u00eatre incluses dans l\u2019\u00e9tude de conception plut\u00f4t que d\u2019\u00eatre laiss\u00e9es comme une hypoth\u00e8se \u00e0 \u00e9tablir apr\u00e8s l\u2019attribution du march\u00e9.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-691a0a74 auto-p elementor-widget elementor-widget-heading\" data-id=\"691a0a74\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">MegSolid <strong><a href=\"https:\/\/www.solidess.com\/fr\/systemes-de-stockage-denergie-a-letat-solide\/\" target=\"_blank\" style=\"color:#61CE70\">Syst\u00e8mes de stockage d'\u00e9nergie \u00e0 l'\u00e9tat solide<\/a><\/strong> Cette page fournit des informations g\u00e9n\u00e9rales sur la cat\u00e9gorie technologique au niveau de l'entreprise. Elle ne doit pas se substituer \u00e0 une d\u00e9claration de compatibilit\u00e9 \u00e9lectrique sp\u00e9cifique \u00e0 un mod\u00e8le, \u00e0 un dossier de certification ou \u00e0 un document de gestion de projet.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f5110453 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"f5110453\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Int\u00e9grer dans le contrat les exigences de conformit\u00e9 br\u00e9siliennes et le p\u00e9rim\u00e8tre local des travaux d'EPC<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ba87fb10 auto-p elementor-widget elementor-widget-heading\" data-id=\"ba87fb10\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\"><strong>La conformit\u00e9 aux exigences locales ne peut \u00eatre pr\u00e9sum\u00e9e sur la base d'une d\u00e9claration g\u00e9n\u00e9rale relative au produit ou d'une r\u00e9f\u00e9rence \u00e0 un certificat g\u00e9n\u00e9rique.<\/strong> Le propri\u00e9taire de l'installation de production doit communiquer au ma\u00eetre d'\u0153uvre local (EPC) et au fournisseur potentiel l'emplacement pr\u00e9vu, les conditions du r\u00e9seau \u00e9lectrique, les exigences applicables au site, la proc\u00e9dure d'autorisation et les contraintes de construction. Le ma\u00eetre d'\u0153uvre local (EPC) doit d\u00e9finir et consigner par \u00e9crit les responsabilit\u00e9s sp\u00e9cifiques au site en mati\u00e8re d'\u00e9lectricit\u00e9, de g\u00e9nie civil, de protection, de s\u00e9curit\u00e9, d'installation et de mise en service, dans le cadre du p\u00e9rim\u00e8tre de son contrat.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8eb17811 auto-p elementor-widget elementor-widget-heading\" data-id=\"8eb17811\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Les certificats sont sp\u00e9cifiques \u00e0 un mod\u00e8le, \u00e0 une configuration et \u00e0 un march\u00e9. Avant de se fonder sur un certificat pour prendre une d\u00e9cision relative \u00e0 un appel d'offres, une homologation, une exp\u00e9dition ou une installation, il convient de se procurer le document correspondant et de v\u00e9rifier le num\u00e9ro de mod\u00e8le exact, la norme applicable, l'organisme \u00e9metteur, le num\u00e9ro de rapport, la dur\u00e9e de validit\u00e9 et la port\u00e9e de la configuration. Une simple r\u00e9f\u00e9rence g\u00e9n\u00e9rale \u00e0 une certification ne doit pas \u00eatre consid\u00e9r\u00e9e comme la preuve qu'un syst\u00e8me propos\u00e9 r\u00e9pond aux exigences d'un site ou d'un march\u00e9.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a7b1a667 auto-p elementor-widget elementor-widget-heading\" data-id=\"a7b1a667\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Les fichiers sources actuels de MegSolid ne contiennent aucune information concernant les exigences r\u00e9glementaires br\u00e9siliennes, les conditions de raccordement propres \u00e0 chaque fournisseur d'\u00e9nergie, le traitement tarifaire, les mesures incitatives et l'acceptation des certificats au niveau local. Les acheteurs doivent se procurer ces informations dans le cadre du processus de projet local et les int\u00e9grer dans le cahier des charges techniques, le p\u00e9rim\u00e8tre du contrat EPC et la liste des documents \u00e0 fournir par les fournisseurs.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-70e1dac7 auto-p elementor-widget elementor-widget-heading\" data-id=\"70e1dac7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">MegSolid <strong><a href=\"https:\/\/www.solidess.com\/fr\/bess\/cas-dapplication\/\" target=\"_blank\" style=\"color:#61CE70\">Exemples d'applications dans le domaine du stockage d'\u00e9nergie<\/a><\/strong> peut fournir un contexte d'application. Une r\u00e9f\u00e9rence ou une description de cas ne permet toutefois pas d'\u00e9tablir que la conception \u00e9lectrique, les autorisations, les hypoth\u00e8ses d'exploitation ou les crit\u00e8res de r\u00e9ception d'un autre projet s'appliqueront \u00e0 un nouveau site de fabrication.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3e75d836 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"3e75d836\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Comparez les devis en vous basant sur les donn\u00e9es concr\u00e8tes plut\u00f4t que sur la capacit\u00e9 nominale<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7c59b7b6 auto-p elementor-widget elementor-widget-heading\" data-id=\"7c59b7b6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Un devis pour un syst\u00e8me de stockage d'\u00e9nergie C&amp;I n'est comparable que lorsque chaque fournisseur r\u00e9pond au m\u00eame cahier des charges technique. La comparaison doit normaliser le mod\u00e8le propos\u00e9, la puissance nominale en courant alternatif, les bases d'\u00e9nergie nominale et utilisable, les limites du syst\u00e8me, les hypoth\u00e8ses d'exploitation, le p\u00e9rim\u00e8tre d'int\u00e9gration, le plan d'essai, les conditions de garantie, les exclusions et les travaux requis sur site. Le prix ne doit \u00eatre \u00e9valu\u00e9 qu'une fois ces diff\u00e9rences mises en \u00e9vidence.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-63b7f490 auto-table elementor-widget elementor-widget-text-editor\" data-id=\"63b7f490\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"cea-table-wrap\"><table><tbody><\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2686b452 auto-p elementor-widget elementor-widget-heading\" data-id=\"2686b452\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Une r\u00e8gle utile en mati\u00e8re d'achats est simple : si une valeur ou une obligation influe sur la d\u00e9cision de l'usine, exigez qu'elle figure dans la proposition et assurez-vous qu'elle soit bien prise en compte dans le mod\u00e8le s\u00e9lectionn\u00e9, les conditions stipul\u00e9es ou les livrables contractuels. Si le fournisseur n'est pas encore en mesure de fournir cette information, identifiez-la comme un point en suspens en d\u00e9signant un responsable et en fixant une date limite, plut\u00f4t que de la transformer tacitement en hypoth\u00e8se.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5077195b auto-h2 elementor-widget elementor-widget-heading\" data-id=\"5077195b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Utilisez les commandes FAT et SAT pour tester la configuration ordonn\u00e9e<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-57e29540 auto-p elementor-widget elementor-widget-heading\" data-id=\"57e29540\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">L'essai de r\u00e9ception en usine doit permettre de v\u00e9rifier la conformit\u00e9 de la configuration command\u00e9e \u00e0 un protocole approuv\u00e9, et non pas constituer une simple d\u00e9monstration g\u00e9n\u00e9rique du produit. Ce protocole doit pr\u00e9ciser le mod\u00e8le et la configuration propos\u00e9s, la documentation applicable, les contr\u00f4les fonctionnels, les contr\u00f4les de protection, les points de communication, les alarmes, les \u00e9tats de commande, ainsi que les justificatifs requis pour la remise du produit. Toute exigence sp\u00e9cifique au site doit \u00eatre clairement attribu\u00e9e aux essais de r\u00e9ception sur site.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-379c7536 auto-p elementor-widget elementor-widget-heading\" data-id=\"379c7536\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Le test de r\u00e9ception sur site doit porter sur les interfaces sp\u00e9cifiques \u00e0 l'installation qui ne peuvent pas \u00eatre enti\u00e8rement valid\u00e9es en usine. En fonction du p\u00e9rim\u00e8tre d\u00e9fini pour le projet, cela peut inclure le c\u00e2blage sur site, les compteurs, les commandes de contr\u00f4le, la coordination des protections, les communications et la limite de charge critique convenue. L\u2019EPC local responsable et le fournisseur doivent convenir de la personne charg\u00e9e de diriger chaque essai, des personnes pr\u00e9sentes en tant que t\u00e9moins, des donn\u00e9es \u00e0 enregistrer et des crit\u00e8res de r\u00e9ception.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-26b9a4e3 auto-p elementor-widget elementor-widget-heading\" data-id=\"26b9a4e3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Pour effectuer des recherches pr\u00e9liminaires, les acheteurs peuvent utiliser la solution de MegSolid <strong><a href=\"https:\/\/www.solidess.com\/fr\/ressource\/\" target=\"_blank\" style=\"color:#61CE70\">Centre de ressources<\/a><\/strong> et <strong><a href=\"https:\/\/www.solidess.com\/fr\/bess\/actualites\/\" target=\"_blank\" style=\"color:#61CE70\">Actualit\u00e9s et analyses de BESS<\/a><\/strong>. Ces ressources ne remplacent pas les protocoles d'essai sign\u00e9s, la documentation sp\u00e9cifique aux mod\u00e8les ni le plan de mise en service du projet.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ea415bd7 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"ea415bd7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Soumettre un appel d'offres donnant lieu \u00e0 une r\u00e9ponse techniquement comparable<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9e33b91c auto-p elementor-widget elementor-widget-heading\" data-id=\"9e33b91c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\"><strong>Un appel d'offres complet permet d'obtenir une r\u00e9ponse technique plus pertinente et de mettre en \u00e9vidence tr\u00e8s t\u00f4t les lacunes au niveau des interfaces.<\/strong> Envoyez le m\u00eame dossier de consultation \u00e0 MegSolid, l'EPC local, et aux autres fournisseurs candidats. Demandez \u00e0 chaque candidat d'\u00e9num\u00e9rer les hypoth\u00e8ses, les \u00e9carts, les exclusions et les informations encore n\u00e9cessaires \u00e0 la conception finale.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e91839d1 elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"e91839d1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Profil de charge de l'usine et planning des charges critiques.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Modes de fonctionnement requis et dur\u00e9e de l'alimentation de secours.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Sch\u00e9ma unifilaire, informations sur la tension disponible sur site et d\u00e9tails relatifs au transformateur.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Informations relatives aux installations photovolta\u00efques, aux groupes \u00e9lectrog\u00e8nes, au r\u00e9seau \u00e9lectrique et aux syst\u00e8mes de contr\u00f4le existants.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Surface disponible, emplacement d'installation, contraintes d'acc\u00e8s et conditions du site.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Autorisations locales requises, normes applicables et exigences en mati\u00e8re de documentation de conformit\u00e9.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Pr\u00e9f\u00e9rence accord\u00e9e \u00e0 la fourniture, \u00e0 l'installation, \u00e0 la mise en service, \u00e0 la formation, \u00e0 la garantie et \u00e0 l'entretien du mat\u00e9riel.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Dispositions requises concernant le FAT, le SAT, la remise des documents et la pr\u00e9sence de t\u00e9moins lors de la r\u00e9ception.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e4530f5a auto-p elementor-widget elementor-widget-heading\" data-id=\"e4530f5a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">L'expression-cl\u00e9 fournie <strong>g-reic \u00e9nergie immobilier r.e.i.c.<\/strong> n'est pas identifi\u00e9 dans les fichiers source actuels de MegSolid en tant que produit, projet, partenaire, certification ou autorit\u00e9 br\u00e9silienne de MegSolid. Il ne doit pas \u00eatre utilis\u00e9 pour d\u00e9finir le p\u00e9rim\u00e8tre d'intervention d'un fournisseur ou son ad\u00e9quation technique, sauf si une partie contractante fournit une preuve \u00e9crite d'un r\u00f4le sp\u00e9cifique dans le cadre du projet.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-640ba7d3 auto-p elementor-widget elementor-widget-heading\" data-id=\"640ba7d3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Pour passer \u00e0 l'\u00e9tape suivante en vous appuyant sur des donn\u00e9es factuelles, veuillez nous transmettre les informations relatives \u00e0 la charge de l'usine, le sch\u00e9ma unifilaire du site, l'objectif d'exploitation et la liste des documents locaux requis via <strong><a href=\"https:\/\/www.solidess.com\/fr\/contacter-megsolid\/\" target=\"_blank\" style=\"color:#61CE70\">Canal de contact de MegSolid<\/a><\/strong>. Demandez une offre sp\u00e9cifique au mod\u00e8le qui pr\u00e9cise clairement la nomenclature, les interfaces, les points en suspens, le plan de test et le p\u00e9rim\u00e8tre EPC local avant de vous engager commercialement.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0da8102 elementor-tablet-align-center elementor-align-center auto-cta elementor-widget elementor-widget-button\" data-id=\"0da8102\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"#elementor-action%3Aaction%3Dpopup%3Aopen%26settings%3DeyJpZCI6Ijk0OCIsInRvZ2dsZSI6ZmFsc2V9\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Demander un devis pour le syst\u00e8me ESS \u00e0 semi-conducteurs MegSolid<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-5e1951cc auto-faq e-flex e-con-boxed e-con e-child\" data-id=\"5e1951cc\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-1a0f863f elementor-widget elementor-widget-heading\" data-id=\"1a0f863f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">FAQ<\/h2>\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-87d6547f e-con-full e-flex e-con e-child\" data-id=\"87d6547f\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-851d30bd elementor-widget elementor-widget-n-accordion\" data-id=\"851d30bd\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;default_state&quot;:&quot;all_collapsed&quot;,&quot;max_items_expended&quot;:&quot;one&quot;,&quot;n_accordion_animation_duration&quot;:{&quot;unit&quot;:&quot;ms&quot;,&quot;size&quot;:400,&quot;sizes&quot;:[]}}\" data-widget_type=\"nested-accordion.default\">\n\t\t\t\t\t\t\t<div class=\"e-n-accordion\" aria-label=\"Accord\u00e9on. Ouvrez les liens \u00e0 l&#039;aide de la touche Entr\u00e9e ou de la barre d&#039;espace, fermez-les avec la touche \u00c9chap et naviguez \u00e0 l&#039;aide des touches fl\u00e9ch\u00e9es.\">\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2230\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"1\" tabindex=\"0\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2230\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Quel est le premier \u00e9l\u00e9ment \u00e0 dimensionner pour un syst\u00e8me de stockage d'\u00e9nergie C&amp;I ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2230\" class=\"elementor-element elementor-element-5b4c98ba e-con-full e-flex e-con e-child\" data-id=\"5b4c98ba\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2230\" class=\"elementor-element elementor-element-63e85dd0 e-con-full e-flex e-con e-child\" data-id=\"63e85dd0\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-1914bc8b elementor-widget elementor-widget-heading\" data-id=\"1914bc8b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">D\u00e9terminez d\u2019abord la puissance nominale et la puissance de cr\u00eate en courant alternatif \u00e0 partir du profil de charge d\u2019usine et du mode de fonctionnement pr\u00e9vu. D\u00e9finissez ensuite la dur\u00e9e requise et demandez une base d\u2019\u00e9nergie utilisable au niveau de la limite de mesure du courant alternatif convenue.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2231\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"2\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2231\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Pourquoi la capacit\u00e9 nominale de la batterie en kWh ne suffit-elle pas pour comparer les offres de syst\u00e8mes de stockage d'\u00e9nergie par batterie (BESS) ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2231\" class=\"elementor-element elementor-element-b6e5b480 e-con-full e-flex e-con e-child\" data-id=\"b6e5b480\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2231\" class=\"elementor-element elementor-element-c35c16ad e-con-full e-flex e-con e-child\" data-id=\"c35c16ad\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-f4ceba37 elementor-widget elementor-widget-heading\" data-id=\"f4ceba37\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">La valeur nominale en kWh ne pr\u00e9cise pas la charge CA prise en charge, la base d'\u00e9nergie utilisable, la plage de SOC, la base de profondeur de d\u00e9charge, la consommation auxiliaire, le traitement des pertes de conversion ni les hypoth\u00e8ses relatives \u00e0 la fin de vie. Les fournisseurs doivent d\u00e9clarer ces conditions de mani\u00e8re coh\u00e9rente.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2232\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"3\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2232\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Que signifie l'acronyme \u00ab BESS \u00bb (syst\u00e8me de stockage d'\u00e9nergie par batterie OEM) dans le domaine des achats ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2232\" class=\"elementor-element elementor-element-cb7dcd6c e-con-full e-flex e-con e-child\" data-id=\"cb7dcd6c\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2232\" class=\"elementor-element elementor-element-47144993 e-con-full e-flex e-con e-child\" data-id=\"47144993\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-9aaa67ba elementor-widget elementor-widget-heading\" data-id=\"9aaa67ba\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Ce document peut d\u00e9crire diff\u00e9rents modes d'approvisionnement, notamment un syst\u00e8me int\u00e9gr\u00e9 ou des \u00e9quipements fournis dans le cadre d'une solution EPC ou de distribution. Il convient de d\u00e9finir la nomenclature, les responsabilit\u00e9s en mati\u00e8re de conception, les essais, la mise en service, la garantie et les exclusions, plut\u00f4t que de se fier \u00e0 l'\u00e9tiquette du fabricant d'\u00e9quipement d'origine (OEM).<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2233\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"4\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2233\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Une usine doit-elle opter pour une armoire d'ext\u00e9rieur ou un syst\u00e8me de stockage d'\u00e9nergie par batterie (BESS) en conteneur ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2233\" class=\"elementor-element elementor-element-381ce8b8 e-con-full e-flex e-con e-child\" data-id=\"381ce8b8\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2233\" class=\"elementor-element elementor-element-6a3e8566 e-con-full e-flex e-con e-child\" data-id=\"6a3e8566\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-02208975 elementor-widget elementor-widget-heading\" data-id=\"02208975\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Le choix d\u00e9pend de la puissance requise et de la dur\u00e9e d'utilisation, de l'encombrement, de l'acc\u00e8s au site, des interfaces \u00e9lectriques, de l'acc\u00e8s pour la maintenance, du mode de refroidissement et du p\u00e9rim\u00e8tre du contrat EPC. Une \u00e9tude sur site et un sch\u00e9ma unifilaire du projet doivent servir de base \u00e0 cette d\u00e9cision.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2234\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"5\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2234\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Quelles informations relatives au PCS un acheteur industriel doit-il demander ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2234\" class=\"elementor-element elementor-element-aa3d30ed e-con-full e-flex e-con e-child\" data-id=\"aa3d30ed\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2234\" class=\"elementor-element elementor-element-71b7045d e-con-full e-flex e-con e-child\" data-id=\"71b7045d\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-01993b98 elementor-widget elementor-widget-heading\" data-id=\"01993b98\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Pr\u00e9cisez le mod\u00e8le exact du PCS, le mode d'alimentation CA, la plage de fonctionnement CC, le dispositif de protection, la configuration du transformateur, l'interface r\u00e9seau, les points de communication et son r\u00f4le au sein du syst\u00e8me. V\u00e9rifiez la compatibilit\u00e9 avec la configuration de batterie propos\u00e9e.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2235\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"6\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2235\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Quelles informations faut-il fournir avant de demander un devis \u00e0 BESS ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2235\" class=\"elementor-element elementor-element-ac7bc095 e-con-full e-flex e-con e-child\" data-id=\"ac7bc095\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2235\" class=\"elementor-element elementor-element-4a62e462 e-con-full e-flex e-con e-child\" data-id=\"4a62e462\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a70af5c7 elementor-widget elementor-widget-heading\" data-id=\"a70af5c7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Veuillez fournir le profil de charge, la liste des charges critiques, la dur\u00e9e requise, les d\u00e9tails relatifs aux installations photovolta\u00efques et aux g\u00e9n\u00e9rateurs existants, le sch\u00e9ma unifilaire, les informations sur les transformateurs, les conditions du site, l'empreinte disponible et les documents de conformit\u00e9 requis. Les fournisseurs doivent indiquer les donn\u00e9es manquantes en les pr\u00e9sentant comme des hypoth\u00e8ses non v\u00e9rifi\u00e9es.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2236\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"7\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2236\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Que doit contenir un rapport FAT relatif \u00e0 un syst\u00e8me de stockage d'\u00e9nergie par batterie (BESS) ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2236\" class=\"elementor-element elementor-element-9bf3b2dd e-con-full e-flex e-con e-child\" data-id=\"9bf3b2dd\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2236\" class=\"elementor-element elementor-element-6aaa78f3 e-con-full e-flex e-con e-child\" data-id=\"6aaa78f3\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-51422620 elementor-widget elementor-widget-heading\" data-id=\"51422620\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Le FAT doit permettre d'identifier la configuration command\u00e9e et de v\u00e9rifier les \u00e9l\u00e9ments convenus en mati\u00e8re de fonctionnalit\u00e9, de protection, de communication, de documentation et de tra\u00e7abilit\u00e9, conform\u00e9ment \u00e0 un protocole approuv\u00e9. Les interfaces sp\u00e9cifiques au site doivent \u00eatre attribu\u00e9es au SAT.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2237\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"8\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2237\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Une d\u00e9claration de conformit\u00e9 g\u00e9n\u00e9rale peut-elle attester de la conformit\u00e9 d'un projet br\u00e9silien ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2237\" class=\"elementor-element elementor-element-9453398f e-con-full e-flex e-con e-child\" data-id=\"9453398f\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2237\" class=\"elementor-element elementor-element-93290749 e-con-full e-flex e-con e-child\" data-id=\"93290749\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-df22b1ee elementor-widget elementor-widget-heading\" data-id=\"df22b1ee\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Non. Procurez-vous le certificat ou le rapport original et v\u00e9rifiez le mod\u00e8le exact, la configuration, la norme, l'organisme \u00e9metteur, le num\u00e9ro du rapport, la dur\u00e9e de validit\u00e9 ainsi que sa pertinence par rapport au march\u00e9 et \u00e0 l'installation vis\u00e9s.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2238\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"9\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2238\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Quelles donn\u00e9es relatives au produit faut-il demander pour le syst\u00e8me MegSolid s\u00e9lectionn\u00e9 ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2238\" class=\"elementor-element elementor-element-3eedd490 e-con-full e-flex e-con e-child\" data-id=\"3eedd490\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2238\" class=\"elementor-element elementor-element-818ebcfe e-con-full e-flex e-con e-child\" data-id=\"818ebcfe\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-f195cc6b elementor-widget elementor-widget-heading\" data-id=\"f195cc6b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Demandez la fiche technique sp\u00e9cifique au mod\u00e8le actuel, la description de la configuration, la nomenclature pour le devis, les certificats applicables, les conditions de garantie, les manuels, les informations relatives \u00e0 l'interface \u00e9lectrique et le p\u00e9rim\u00e8tre des tests FAT\/SAT. N'utilisez pas les param\u00e8tres d'un autre mod\u00e8le ou d'une autre cat\u00e9gorie de produits.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2239\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"10\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2239\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Qui est responsable de l'int\u00e9gration du syst\u00e8me de stockage d'\u00e9nergie par batterie (BESS) dans une usine ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2239\" class=\"elementor-element elementor-element-75731c6f e-con-full e-flex e-con e-child\" data-id=\"75731c6f\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2239\" class=\"elementor-element elementor-element-75a6fa8c e-con-full e-flex e-con e-child\" data-id=\"75a6fa8c\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-582e28d3 elementor-widget elementor-widget-heading\" data-id=\"582e28d3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Les responsabilit\u00e9s doivent \u00eatre clairement d\u00e9finies dans le contrat. Le fournisseur, l'EPC et le ma\u00eetre d'ouvrage doivent se r\u00e9partir explicitement les t\u00e2ches suivantes : fourniture des \u00e9quipements, travaux de g\u00e9nie civil, installation \u00e9lectrique, coordination des protections, int\u00e9gration des syst\u00e8mes de contr\u00f4le, mise en service, obtention des autorisations et service apr\u00e8s-vente.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-22310\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"11\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-22310\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Existe-t-il un d\u00e9ploiement confirm\u00e9 du syst\u00e8me MegSolid BESS dans l'industrie manufacturi\u00e8re br\u00e9silienne ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-22310\" class=\"elementor-element elementor-element-f2d621da e-con-full e-flex e-con e-child\" data-id=\"f2d621da\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-22310\" class=\"elementor-element elementor-element-88d7ba07 e-con-full e-flex e-con e-child\" data-id=\"88d7ba07\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a09a56d4 elementor-widget elementor-widget-heading\" data-id=\"a09a56d4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Ces informations ne figurent pas dans les fichiers source actuels de MegSolid. L'acheteur doit demander les r\u00e9f\u00e9rences de projets pertinentes directement au fournisseur et v\u00e9rifier leur ad\u00e9quation avec le mode de fonctionnement envisag\u00e9, la configuration du syst\u00e8me et les conditions du site.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-22311\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"12\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-22311\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Quels \u00e9l\u00e9ments un fabricant br\u00e9silien doit-il v\u00e9rifier aupr\u00e8s de son EPC local avant de commander un syst\u00e8me de stockage d'\u00e9nergie par batterie (BESS) ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-22311\" class=\"elementor-element elementor-element-f9ccba6c e-con-full e-flex e-con e-child\" data-id=\"f9ccba6c\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-22311\" class=\"elementor-element elementor-element-72bd97ba e-con-full e-flex e-con e-child\" data-id=\"72bd97ba\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-cf6ad336 elementor-widget elementor-widget-heading\" data-id=\"cf6ad336\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">V\u00e9rifiez la conception \u00e9lectrique du site, les obligations relatives au raccordement au r\u00e9seau, les exigences applicables, la proc\u00e9dure d'homologation, la m\u00e9thode d'installation, la coordination des protections, le plan de mise en service et les responsabilit\u00e9s en mati\u00e8re de r\u00e9ception. Ces \u00e9l\u00e9ments d\u00e9pendent du site et ne peuvent pas \u00eatre d\u00e9duits \u00e0 partir de la fiche produit.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-22312\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"13\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-22312\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> La soci\u00e9t\u00e9 G-Reic Energy Real Estate (REIC) est-elle li\u00e9e \u00e0 MegSolid ou \u00e0 cette s\u00e9ance d'information sur les march\u00e9s publics ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-22312\" class=\"elementor-element elementor-element-5b4620de e-con-full e-flex e-con e-child\" data-id=\"5b4620de\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-22312\" class=\"elementor-element elementor-element-82f98ed8 e-con-full e-flex e-con e-child\" data-id=\"82f98ed8\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-f0f69e4c elementor-widget elementor-widget-heading\" data-id=\"f0f69e4c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Aucun lien n'est identifi\u00e9 dans les fichiers source MegSolid actuels. Consid\u00e9rez cette mention comme sans rapport avec l'\u00e9valuation technique, \u00e0 moins qu'une partie contractante ne fournisse une preuve \u00e9crite d'un r\u00f4le bien d\u00e9fini dans le projet.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-22313\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"14\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-22313\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Que signifie l'acronyme \u00ab BESS \u00bb (syst\u00e8me de stockage d'\u00e9nergie par batterie OEM) dans le domaine des achats ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-22313\" class=\"elementor-element elementor-element-0f7c4ec1 e-con-full e-flex e-con e-child\" data-id=\"0f7c4ec1\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-22313\" class=\"elementor-element elementor-element-eeba49fe e-con-full e-flex e-con e-child\" data-id=\"eeba49fe\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-114a5520 elementor-widget elementor-widget-heading\" data-id=\"114a5520\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Ce document peut d\u00e9crire diff\u00e9rents modes d'approvisionnement, notamment un syst\u00e8me int\u00e9gr\u00e9 ou des \u00e9quipements fournis dans le cadre d'une solution EPC ou de distribution. Il convient de d\u00e9finir la nomenclature, les responsabilit\u00e9s en mati\u00e8re de conception, les essais, la mise en service, la garantie et les exclusions, plut\u00f4t que de se fier \u00e0 l'\u00e9tiquette du fabricant d'\u00e9quipement d'origine (OEM).<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-22314\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"15\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-22314\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Une d\u00e9claration de conformit\u00e9 g\u00e9n\u00e9rale peut-elle attester de la conformit\u00e9 d'un projet br\u00e9silien ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-22314\" class=\"elementor-element elementor-element-6389ebc1 e-con-full e-flex e-con e-child\" data-id=\"6389ebc1\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-22314\" class=\"elementor-element elementor-element-c6249961 e-con-full e-flex e-con e-child\" data-id=\"c6249961\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-b91520c1 elementor-widget elementor-widget-heading\" data-id=\"b91520c1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Non. Procurez-vous le certificat ou le rapport original et v\u00e9rifiez le mod\u00e8le exact, la configuration, la norme, l'organisme \u00e9metteur, le num\u00e9ro du rapport, la dur\u00e9e de validit\u00e9 ainsi que sa pertinence par rapport au march\u00e9 et \u00e0 l'installation vis\u00e9s.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-22315\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"16\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-22315\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Quels \u00e9l\u00e9ments un fabricant br\u00e9silien doit-il v\u00e9rifier aupr\u00e8s de son EPC local avant de commander un syst\u00e8me de stockage d'\u00e9nergie par batterie (BESS) ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-22315\" class=\"elementor-element elementor-element-396574ec e-con-full e-flex e-con e-child\" data-id=\"396574ec\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-22315\" class=\"elementor-element elementor-element-c54741f0 e-con-full e-flex e-con e-child\" data-id=\"c54741f0\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-14d9a683 elementor-widget elementor-widget-heading\" data-id=\"14d9a683\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">V\u00e9rifiez la conception \u00e9lectrique du site, les obligations relatives au raccordement au r\u00e9seau, les exigences applicables, la proc\u00e9dure d'homologation, la m\u00e9thode d'installation, la coordination des protections, le plan de mise en service et les responsabilit\u00e9s en mati\u00e8re de r\u00e9ception. Ces \u00e9l\u00e9ments d\u00e9pendent du site et ne peuvent pas \u00eatre d\u00e9duits \u00e0 partir de la fiche produit.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Une demande de devis concernant un syst\u00e8me de stockage d'\u00e9nergie par batterie (BESS) destin\u00e9 aux \u00e9quipementiers n'est comparable que si tous les fournisseurs re\u00e7oivent le m\u00eame cahier des charges technique. Utilisez ce guide pour d\u00e9finir les charges de l'usine, les limites du syst\u00e8me, les exigences en mati\u00e8re de documentation et les responsabilit\u00e9s en mati\u00e8re de r\u00e9ception avant de demander des devis.<\/p>","protected":false},"author":4,"featured_media":4446,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"_joinchat":[],"footnotes":""},"categories":[1,713],"tags":[197,195,31,198,196],"class_list":["post-4445","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-bess","category-bess-procurement-economics","tag-bess-acceptance-testing","tag-brazilian-factory-bess","tag-ci-energy-storage","tag-epc-scope-management","tag-oem-bess-procurement"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/posts\/4445","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/comments?post=4445"}],"version-history":[{"count":4,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/posts\/4445\/revisions"}],"predecessor-version":[{"id":4450,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/posts\/4445\/revisions\/4450"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/media\/4446"}],"wp:attachment":[{"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/media?parent=4445"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/categories?post=4445"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/tags?post=4445"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}