{"id":4479,"date":"2026-08-03T11:47:12","date_gmt":"2026-08-03T03:47:12","guid":{"rendered":"https:\/\/www.solidess.com\/?p=4479"},"modified":"2026-10-13T17:53:57","modified_gmt":"2026-10-13T09:53:57","slug":"dimensionnement-dusine-de-stockage-de-batteries-commerciales-en-afrique-du-sud","status":"publish","type":"post","link":"https:\/\/www.solidess.com\/fr\/commercial-battery-storage-south-africa-factory-sizing\/","title":{"rendered":"Comment d\u00e9terminer la capacit\u00e9 d'un syst\u00e8me de stockage par batterie \u00e0 usage commercial pour une usine sud-africaine"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"4479\" class=\"elementor elementor-4479\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-bf4793c e-con-full auto-article-root e-flex e-con e-parent\" data-id=\"bf4793c\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-2c7b05a8 auto-p elementor-widget elementor-widget-heading\" data-id=\"2c7b05a8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Dimensions MegSolid <strong>stockage commercial par batterie en Afrique du Sud<\/strong> en fonction de la charge d'exploitation de l'usine, et non pas uniquement sur la base de la consommation mensuelle en kWh. Le moyen le plus rapide d'aboutir \u00e0 une \u00e9tude pr\u00e9liminaire viable sur le plan financier consiste \u00e0 d\u00e9finir quatre param\u00e8tres : le d\u00e9ficit de puissance en kW, la plage d'\u00e9nergie utilisable en kWh, la priorit\u00e9 de contr\u00f4le du syst\u00e8me de gestion de l'\u00e9nergie (EMS) et le point de livraison du courant alternatif que l'EPC ou le prestataire de services \u00e9nerg\u00e9tiques doit garantir.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-616e8ba5 auto-image elementor-widget elementor-widget-image\" data-id=\"616e8ba5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"800\" height=\"800\" src=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/Commercial-Battery-Storage-for-South-African-Factories.png\" class=\"attachment-1536x1536 size-1536x1536 wp-image-4476\" alt=\"Le syst\u00e8me commercial de stockage d&#039;\u00e9nergie par batterie MegSolid accompagne une usine sud-africaine en lui fournissant de l&#039;\u00e9nergie solaire, en assurant la r\u00e9duction des pics de consommation et en offrant une alimentation de secours\" srcset=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/Commercial-Battery-Storage-for-South-African-Factories.png 800w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/Commercial-Battery-Storage-for-South-African-Factories-300x300.png 300w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/Commercial-Battery-Storage-for-South-African-Factories-150x150.png 150w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/Commercial-Battery-Storage-for-South-African-Factories-768x768.png 768w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/Commercial-Battery-Storage-for-South-African-Factories-600x600.png 600w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/Commercial-Battery-Storage-for-South-African-Factories-100x100.png 100w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-45436710 elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"45436710\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">\u26a1 <strong>La puissance avant tout :<\/strong> D\u00e9terminer la puissance en kW \u00e0 partir de l'\u00e9cart de charge simultan\u00e9e le plus important, de l'objectif d'\u00e9cr\u00eatement des pics ou du seuil de charge critique.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">\u23f1\ufe0f <strong>Dur\u00e9e d'ex\u00e9cution en secondes :<\/strong> Convertir la plage de puissance requise en kWh CA utilisables, puis tenir compte des limites de fonctionnement et des pertes.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">\ud83e\udde0 <strong>EMS, troisi\u00e8me :<\/strong> D\u00e9terminez quel objectif pr\u00e9vaut lorsque la r\u00e9serve de secours, la recharge solaire et l'\u00e9cr\u00eatement des pics se disputent le m\u00eame niveau de charge (SOC).<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">\ud83d\udccd <strong>Lieu de livraison :<\/strong> Pr\u00e9cisez si les performances sont mesur\u00e9es au niveau des bornes CC de la batterie, \u00e0 la sortie du PCS, au niveau du tableau principal BT ou au point de couplage commun.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">\ud83d\udcc4 <strong>Justificatifs de l'appel d'offres :<\/strong> Fournir \u00e0 chaque soumissionnaire les m\u00eames donn\u00e9es de charge, le m\u00eame tarif, le m\u00eame SLD, les m\u00eames conditions sur site et les m\u00eames tests de r\u00e9ception.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0e5d8451 elementor-tablet-align-center elementor-align-center auto-cta elementor-widget elementor-widget-button\" data-id=\"0e5d8451\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"#elementor-action%3Aaction%3Dpopup%3Aopen%26settings%3DeyJpZCI6Ijk0OCIsInRvZ2dsZSI6ZmFsc2V9\" target=\"_blank\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Obtenir une estimation pr\u00e9liminaire de la taille de mon syst\u00e8me BESS d'usine<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-79174efb auto-h2 elementor-widget elementor-widget-heading\" data-id=\"79174efb\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">La r\u00e9ponse directe : choisir la puissance du chargeur avant celle de la batterie<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4a933e06 auto-p elementor-widget elementor-widget-heading\" data-id=\"4a933e06\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Pour une usine sud-africaine, utilisez des donn\u00e9es \u00e0 intervalles de 15 ou 30 minutes afin d\u2019\u00e9tablir le profil de charge normal, puis obtenez des donn\u00e9es \u00e0 plus haute r\u00e9solution pour les d\u00e9marrages de moteurs ou les \u00e9tapes rapides du processus. La puissance requise pour le syst\u00e8me de stockage d\u2019\u00e9nergie par batterie (BESS) correspond \u00e0 l\u2019\u00e9cart maximal de charge contr\u00f4l\u00e9. L\u2019\u00e9nergie requise correspond \u00e0 l\u2019aire sous cet \u00e9cart pour la plage de fonctionnement garantie, ajust\u00e9e au point de mesure CA convenu.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5526380f auto-table elementor-widget elementor-widget-text-editor\" data-id=\"5526380f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"cea-table-wrap\"><table><thead><tr><th>Objectif de l'usine<\/th><th>Variable principale de dimensionnement<\/th><th>Justificatifs requis<\/th><th>Erreur courante<\/th><\/tr><\/thead><tbody><tr><td>\u00c9galisation de la charge<\/td><td>la diff\u00e9rence en kW par rapport \u00e0 l'objectif d'importation et la dur\u00e9e de chaque \u00e9v\u00e9nement<\/td><td>Donn\u00e9es de charge par intervalle, tarif, NMD et r\u00e8gles relatives aux p\u00e9riodes de pointe<\/td><td>Calcul de la taille \u00e0 partir de la valeur nominale la plus \u00e9lev\u00e9e d'un billet, sans tenir compte de sa dur\u00e9e<\/td><\/tr><tr><td>Sauvegarde en cas de charge critique<\/td><td>Puissance critique en kW, charges par paliers et plage d'autonomie<\/td><td>Calendrier des charges critiques, caract\u00e9ristiques du moteur et s\u00e9quence d'arr\u00eat<\/td><td>En partant du principe que l'ensemble de l'usine doit continuer \u00e0 fonctionner sans changement<\/td><\/tr><tr><td>Autoconsommation solaire<\/td><td>Exc\u00e9dent d'\u00e9nergie photovolta\u00efque et fen\u00eatre de charge ult\u00e9rieure<\/td><td>Profil de production photovolta\u00efque, limite d'exportation et historique des restrictions de production<\/td><td>Adapter la capacit\u00e9 en kWh de la batterie \u00e0 la puissance nominale en kWp de l'installation photovolta\u00efque<\/td><\/tr><tr><td>Optimisation des g\u00e9n\u00e9rateurs<\/td><td>Charge minimale du g\u00e9n\u00e9rateur et soutien transitoire<\/td><td>Caract\u00e9ristiques techniques du g\u00e9n\u00e9rateur, commandes, courbe de consommation de carburant et s\u00e9quence de d\u00e9marrage<\/td><td>Raccordement de deux sources de formation de r\u00e9seau sans \u00e9tude de contr\u00f4le<\/td><\/tr><tr><td>Prestation de services \u00e9nerg\u00e9tiques ou fourniture dans le cadre d'un contrat d'achat d'\u00e9lectricit\u00e9 (PPA)<\/td><td>Puissance et \u00e9nergie garanties au compteur de r\u00e8glement<\/td><td>D\u00e9lai de livraison, r\u00e8gles relatives au compteur, exclusions et recours<\/td><td>Utilisation de la capacit\u00e9 nominale de la batterie comme valeur de livraison contractuelle<\/td><\/tr><\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2bd7b16e auto-p elementor-widget elementor-widget-heading\" data-id=\"2bd7b16e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">En Afrique du Sud, les structures tarifaires varient selon les sites. Eskom publie les tarifs urbains destin\u00e9s aux grands consommateurs industriels et commerciaux, tandis que les tarifs municipaux et les r\u00e8gles relatives \u00e0 la production int\u00e9gr\u00e9e diff\u00e8rent selon les distributeurs. Consultez le bar\u00e8me applicable pour 2026\/27 sur le site <strong><a href=\"https:\/\/www.eskom.co.za\/distribution\/tariffs-and-charges\/\" target=\"_blank\" style=\"color:#61CE70\" rel=\"noopener\">Page consacr\u00e9e aux tarifs et aux frais d'Eskom<\/a><\/strong> et v\u00e9rifier la facture r\u00e9elle de l'usine avant d'attribuer les \u00e9conomies r\u00e9alis\u00e9es \u00e0 un syst\u00e8me de stockage d'\u00e9nergie par batterie (BESS).<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-008b7e2f auto-h2 elementor-widget elementor-widget-heading\" data-id=\"008b7e2f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">\u00c9tape 1 : R\u00e9partir la charge d'usine en trois couches<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-230f60fc auto-p elementor-widget elementor-widget-heading\" data-id=\"230f60fc\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Un mod\u00e8le de charge utile pour une centrale ne se r\u00e9sume pas \u00e0 une simple moyenne. Il convient de distinguer les charges critiques pour la production, qui doivent rester sous tension, des charges diff\u00e9r\u00e9es, dont l'activation peut \u00eatre programm\u00e9e, et des charges transitoires de courte dur\u00e9e, susceptibles d'entra\u00eener une surcharge du PCS ou une interaction avec le g\u00e9n\u00e9rateur. Cette distinction permet souvent de r\u00e9duire les besoins en r\u00e9serve sans compromettre la r\u00e9silience op\u00e9rationnelle.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1b0ea402 elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"1b0ea402\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">\ud83c\udfed <strong>Essentiel pour la production :<\/strong> Syst\u00e8mes de commande, \u00e9quipements de processus essentiels, syst\u00e8mes de r\u00e9frig\u00e9ration, syst\u00e8mes de s\u00e9curit\u00e9, syst\u00e8mes de communication et lignes de production homologu\u00e9es.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">\ud83d\udd00 <strong>S\u00e9quen\u00e7able :<\/strong> Compresseurs, pompes, \u00e9tages de climatisation, chargeurs et conduites non essentielles pouvant \u00eatre remis en service par \u00e9tapes contr\u00f4l\u00e9es.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">\ud83d\udcc8 <strong>Transitoire :<\/strong> Courants d'appel des moteurs, postes \u00e0 souder, presses, ascenseurs et autres charges dont les pics de courte dur\u00e9e peuvent d\u00e9passer la moyenne des donn\u00e9es d'intervalle.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">\ud83d\udeab <strong>Sont exclus :<\/strong> Charges d\u00e9lib\u00e9r\u00e9ment d\u00e9lest\u00e9es lors d\u2019une coupure de courant ou d\u2019une intervention de r\u00e9gulation tarifaire.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-16ba4ebd auto-p elementor-widget elementor-widget-heading\" data-id=\"16ba4ebd\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Si le d\u00e9marrage du moteur pose probl\u00e8me, ne le r\u00e9solvez pas en vous contentant d'ajouter de l'\u00e9nergie provenant de la batterie. V\u00e9rifiez la capacit\u00e9 de surcharge du PCS, les chutes de tension, la puissance r\u00e9active, l'imp\u00e9dance du transformateur et la s\u00e9quence de red\u00e9marrage. Le <strong><a href=\"https:\/\/www.solidess.com\/fr\/ideal-pour-le-demarrage-de-gros-moteurs\/\" target=\"_blank\" style=\"color:#61CE70\">Guide technique BESS pour les moteurs de grande puissance<\/a><\/strong> explique pourquoi un devis bas\u00e9 uniquement sur le kWh peut s'av\u00e9rer insuffisant lors de la mise en service.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-fe8b3619 auto-image elementor-widget elementor-widget-image\" data-id=\"fe8b3619\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"1200\" height=\"900\" src=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/South-Africa-Factory-BESS-Power-and-Runtime-Sizing.png\" class=\"attachment-1536x1536 size-1536x1536 wp-image-4477\" alt=\"Sch\u00e9ma de dimensionnement de l&#039;usine BESS pour l&#039;Afrique du Sud, indiquant le profil de charge, la puissance de pointe, l&#039;autonomie de charge critique et l&#039;\u00e9nergie CA utilisable\" srcset=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/South-Africa-Factory-BESS-Power-and-Runtime-Sizing.png 1200w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/South-Africa-Factory-BESS-Power-and-Runtime-Sizing-300x225.png 300w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/South-Africa-Factory-BESS-Power-and-Runtime-Sizing-1024x768.png 1024w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/South-Africa-Factory-BESS-Power-and-Runtime-Sizing-768x576.png 768w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/South-Africa-Factory-BESS-Power-and-Runtime-Sizing-600x450.png 600w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e1ae92c1 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"e1ae92c1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">\u00c9tape 2 : Calculer la puissance, l'autonomie et l'\u00e9nergie nominale<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-914b662f auto-p elementor-widget elementor-widget-heading\" data-id=\"914b662f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Pour l'\u00e9cr\u00eatement des pointes, la puissance pr\u00e9liminaire correspond \u00e0 la charge maximale sup\u00e9rieure \u00e0 la limite d'injection dans le r\u00e9seau choisie. Pour le secours, elle correspond \u00e0 la charge critique simultan\u00e9e apr\u00e8s application des mesures de d\u00e9lestage et de s\u00e9quencement approuv\u00e9es. Utilisez la valeur la plus \u00e9lev\u00e9e lorsqu'un PCS doit prendre en charge les deux modes, puis testez les transitoires s\u00e9par\u00e9ment.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-83bb5d82 auto-table elementor-widget elementor-widget-text-editor\" data-id=\"83bb5d82\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"cea-table-wrap\"><table><thead><tr><th>Calcul<\/th><th>Formule pr\u00e9liminaire<\/th><th>\u00c9l\u00e9ments \u00e0 pr\u00e9ciser dans l'appel d'offres<\/th><\/tr><\/thead><tbody><tr><td>\u00c9lectricit\u00e9 destin\u00e9e \u00e0 l'\u00e9cr\u00eatement des pics de consommation<\/td><td>Charge maximale du site \u2212 objectif d'importation du r\u00e9seau<\/td><td>Point de comptage, intervalle de calcul de la moyenne et calendrier cible<\/td><\/tr><tr><td>Alimentation de secours<\/td><td>Somme des charges critiques simultan\u00e9es<\/td><td>S\u00e9quence de d\u00e9lestage, \u00e9v\u00e9nements d\u00e9clencheurs et facteur de puissance<\/td><\/tr><tr><td>\u00c9nergie CA exploitable<\/td><td>Puissance CA requise \u00d7 dur\u00e9e de fonctionnement<\/td><td>Si la charge varie d'un c\u00f4t\u00e9 \u00e0 l'autre de la fen\u00eatre<\/td><\/tr><tr><td>\u00c9nergie nominale de la batterie<\/td><td>\u00c9nergie CA utilisable \u00f7 facteur d'utilisation du syst\u00e8me<\/td><td>DOD autoris\u00e9, pertes de conversion, services auxiliaires, vieillissement et r\u00e9serve<\/td><\/tr><\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ddd377ef auto-h3 elementor-widget elementor-widget-heading\" data-id=\"ddd377ef\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Exemple de calcul en usine<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f2b8c0b0 auto-p elementor-widget elementor-widget-heading\" data-id=\"f2b8c0b0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Supposons qu\u2019une usine souhaite limiter ses pr\u00e9l\u00e8vements sur le r\u00e9seau \u00e0 90 kW pendant 1,5 heure. Les besoins c\u00f4t\u00e9 charge s\u2019\u00e9l\u00e8vent \u00e0 135 kWh. Si le facteur de rendement pr\u00e9liminaire du syst\u00e8me est de 0,80, la valeur de r\u00e9f\u00e9rence est de 168,75 kWh nominaux. La valeur de 0,80 est une hypoth\u00e8se du projet \u2014 et non une sp\u00e9cification du produit MegSolid \u2014 et doit \u00eatre remplac\u00e9e par le DOD autoris\u00e9, les pertes pr\u00e9vues, la r\u00e9serve et les conditions de garantie de la configuration choisie.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4bc5dc23 auto-p elementor-widget elementor-widget-heading\" data-id=\"4bc5dc23\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Ce r\u00e9sultat de pr\u00e9s\u00e9lection permet \u00e0 une armoire de la cat\u00e9gorie 100 kW \/ 215,04 kWh d'acc\u00e9der \u00e0 la premi\u00e8re \u00e9tape d'examen technique, mais cela ne signifie pas pour autant que la conception soit finalis\u00e9e. Le <strong><a href=\"https:\/\/www.solidess.com\/fr\/comment-selectionner-un-systeme-de-stockage-denergie-par-batterie-bess-exterieur-de-100-kw-215-kwh-pour-un-site-commercial-et-industriel-ci\/\" target=\"_blank\" style=\"color:#61CE70\">Guide de s\u00e9lection d'un syst\u00e8me de stockage d'\u00e9nergie (BESS) ext\u00e9rieur de 100 kW \/ 215 kWh<\/a><\/strong> doit servir \u00e0 v\u00e9rifier l'interface CA, la fen\u00eatre de fonctionnement, l'environnement et les limites de contr\u00f4le. Si le lissage des pics et la r\u00e9serve de secours sont requis le m\u00eame jour, le syst\u00e8me de gestion de l'\u00e9nergie (EMS) doit emp\u00eacher qu'un service ne consomme l'\u00e9nergie promise \u00e0 l'autre.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b60844a7 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"b60844a7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">\u00c9tape 3 : Transformer l'EMS en contrat d'exploitation<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-82c7f32a auto-p elementor-widget elementor-widget-heading\" data-id=\"82c7f32a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Un syst\u00e8me de gestion de l'\u00e9nergie (EMS) ne tire pas sa valeur du simple fait qu'il dispose d'un tableau de bord. Il doit prendre des d\u00e9cisions reproductibles au point de couplage commun, tout en respectant les contraintes li\u00e9es \u00e0 la batterie, au syst\u00e8me de contr\u00f4le de puissance (PCS), au r\u00e9seau, au g\u00e9n\u00e9rateur et au processus. Pr\u00e9cisez dans l'appel d'offres l'ordre de priorit\u00e9, la source de mesure, la logique de r\u00e9ponse, l'\u00e9tat de secours et les autorisations accord\u00e9es aux op\u00e9rateurs.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-21fb33ff elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"21fb33ff\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">\ud83d\udee1\ufe0f <strong>Consignes de s\u00e9curit\u00e9 et limites de l'\u00e9quipement :<\/strong> Les limites BMS et PCS pr\u00e9valent sur les commandes de r\u00e9partition commerciales.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">\ud83d\udd0b <strong>R\u00e9serve de s\u00e9curit\u00e9 :<\/strong> Maintenir une bande SOC minimale pendant la plage horaire convenue pour les charges critiques.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">\ud83d\udcc9 <strong>Objectif maximal :<\/strong> Ne proc\u00e9der \u00e0 la d\u00e9charge que lorsque l'importation de PCC mesur\u00e9e approche de la limite pr\u00e9vue.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">\u2600\ufe0f <strong>Utilisation de l'\u00e9nergie solaire :<\/strong> Pr\u00e9voir une marge de man\u0153uvre en mati\u00e8re de tarification avant l\u2019exc\u00e9dent pr\u00e9vu, sans pour autant compromettre la r\u00e9serve.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">\u26fd <strong>Coordination des g\u00e9n\u00e9rateurs :<\/strong> D\u00e9finir la logique de d\u00e9marrage, de synchronisation, de charge minimale, d'autorisation de charge et d'arr\u00eat.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">\ud83d\udea6 <strong>Mode de d\u00e9faillance :<\/strong> D\u00e9finir l'\u00e9tat de fonctionnement s\u00e9curis\u00e9 en cas de d\u00e9faillance d'un compteur, du syst\u00e8me de communication ou d'un r\u00e9gulateur.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a2cef117 auto-p elementor-widget elementor-widget-heading\" data-id=\"a2cef117\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">La plateforme ESSA de MegSolid propose des fonctions EMS int\u00e9gr\u00e9es, un acc\u00e8s simultan\u00e9 \u00e0 la charge, \u00e0 la batterie, au r\u00e9seau, au g\u00e9n\u00e9rateur diesel et au syst\u00e8me photovolta\u00efque, ainsi que la pr\u00e9vision de la capacit\u00e9 de la batterie et de son autonomie. Les protocoles de communication mentionn\u00e9s sont RS485 et TCP\/IP. Ces fonctionnalit\u00e9s n\u00e9cessitent toutefois une carte des registres sp\u00e9cifique au projet, un cahier des charges de contr\u00f4le et un test de r\u00e9ception en pr\u00e9sence d\u2019un t\u00e9moin ; le simple fait de citer un nom de protocole ne suffit pas \u00e0 prouver l\u2019interop\u00e9rabilit\u00e9.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9ab156d8 auto-image elementor-widget elementor-widget-image\" data-id=\"9ab156d8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"1200\" height=\"900\" src=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/Factory-BESS-EMS-Control-and-RFQ-Boundary.png\" class=\"attachment-1536x1536 size-1536x1536 wp-image-4478\" alt=\"Syst\u00e8me de contr\u00f4le BESS EMS de MegSolid et appel d&#039;offres EPC pour un r\u00e9seau reliant le r\u00e9seau \u00e9lectrique, les installations solaires, les groupes \u00e9lectrog\u00e8nes, les charges critiques et le stockage par batterie\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c200075a auto-h2 elementor-widget elementor-widget-heading\" data-id=\"c200075a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">\u00c9tape 4 : Associer la fonction pr\u00e9liminaire \u00e0 une plateforme MegSolid<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-165ca6ad auto-p elementor-widget elementor-widget-heading\" data-id=\"165ca6ad\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Le choix du mod\u00e8le MegSolid le plus adapt\u00e9 d\u00e9pend de la puissance, de la consommation d'\u00e9nergie, du refroidissement, des conditions du site et de l'int\u00e9gration \u2014 et pas uniquement du nombre de kWh. Utilisez le <strong><a href=\"https:\/\/www.solidess.com\/fr\/systemes-de-stockage-denergie-a-letat-solide\/\" target=\"_blank\" style=\"color:#61CE70\">Pr\u00e9sentation des syst\u00e8mes de stockage d'\u00e9nergie \u00e0 l'\u00e9tat solide MegSolid<\/a><\/strong> pour discuter des architectures disponibles, puis demander la fiche technique du mod\u00e8le certifi\u00e9 et la nomenclature du projet correspondant \u00e0 la configuration propos\u00e9e.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-abdc92e5 auto-table elementor-widget elementor-widget-text-editor\" data-id=\"abdc92e5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"cea-table-wrap\"><table><thead><tr><th>Plateforme MegSolid certifi\u00e9e<\/th><th>Note publi\u00e9e<\/th><th>Montage pr\u00e9liminaire en usine<\/th><th>R\u00e9serve essentielle<\/th><\/tr><\/thead><tbody><tr><td>S\u00e9rie d'armoires d'ext\u00e9rieur ESSA<\/td><td>30 \u00e0 100 kW \/ 55,296 \u00e0 215,04 kWh<\/td><td>Syst\u00e8me modulaire C&amp;I assurant des fonctions de lissage des pics de consommation, d'alimentation de secours et de stockage d'\u00e9nergie solaire<\/td><td>Refroidissement par air intelligent ; 0\u201345 \u00b0C ; IP54 ; puissance et consommation sp\u00e9cifiques au mod\u00e8le<\/td><\/tr><tr><td>ESSA0100B-0215<\/td><td>100 kW \/ 215,04 kWh (valeur nominale)<\/td><td>Contr\u00f4le de deux heures pour les charges inf\u00e9rieures \u00e0 la puissance nominale, sous r\u00e9serve de l'\u00e9nergie disponible<\/td><td>Le tableau standard indique une capacit\u00e9 de 280 Ah pour les batteries LFP ; les cellules \u00e0 semi-conducteurs constituent une option sp\u00e9cifique au projet.<\/td><\/tr><tr><td>Syst\u00e8me Meg-Solid Energon C&amp;I<\/td><td>125 kVA \/ 261,24 kWh (valeur nominale)<\/td><td>Fonctionnement C&amp;I \u00e0 haute \u00e9nergie et s\u00e9lection de sites chauds<\/td><td>314 Ah LFP, refroidissement par liquide ; la valeur en kVA ne doit pas \u00eatre consid\u00e9r\u00e9e comme une valeur garantie en kW sans v\u00e9rification du facteur de puissance<\/td><\/tr><tr><td>S\u00e9rie de conteneurs ESSC<\/td><td>500 kW \/ 1,0752 MWh ou 1 MW \/ 2,1504 MWh<\/td><td>Grands sites industriels ou missions modulaires de plusieurs heures<\/td><td>LFP, refroidissement par air \u00e0 r\u00e9gulation intelligente de la temp\u00e9rature et int\u00e9gration au niveau du projet<\/td><\/tr><\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0fa86a8e auto-p elementor-widget elementor-widget-heading\" data-id=\"0fa86a8e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Le <strong><a href=\"https:\/\/www.solidess.com\/fr\/guide-des-rfq-pour-le-systeme-de-stockage-denergie-refroidi-par-liquide-de-261-kwh\/\" target=\"_blank\" style=\"color:#61CE70\">Guide d'appel d'offres pour un syst\u00e8me de refroidissement par liquide de 261,24 kWh<\/a><\/strong> permet aux acheteurs de comparer cette plateforme avec des armoires \u00e0 refroidissement par air sur la base des m\u00eames mesures. Ne qualifiez pas le rendement maximal du syst\u00e8me 90% indiqu\u00e9 sur sa page produit de \u00ab rendement aller-retour \u00bb ; demandez la d\u00e9finition exacte du rendement ainsi que les conditions d'essai.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4f5e5306 auto-h3 elementor-widget elementor-widget-heading\" data-id=\"4f5e5306\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Quand une configuration \u00e0 semi-conducteurs apporte une valeur ajout\u00e9e en mati\u00e8re d'approvisionnement<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-13bd03a9 auto-p elementor-widget elementor-widget-heading\" data-id=\"13bd03a9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Une option de cellule \u00e0 semi-conducteurs sp\u00e9cifique \u00e0 un projet peut permettre de r\u00e9duire les stocks de liquides inflammables et d\u2019am\u00e9liorer la r\u00e9sistance \u00e0 certains m\u00e9canismes d\u2019utilisation abusive ou de propagation, \u00e0 condition qu\u2019elle s\u2019appuie sur des donn\u00e9es issues de la mod\u00e9lisation. Elle ne doit en aucun cas \u00eatre pr\u00e9sent\u00e9e comme un moyen d\u2019\u00e9liminer l\u2019emballement thermique, de rendre l\u2019armoire ignifuge ou de rendre superflus les limiteurs du syst\u00e8me de gestion de batterie (BMS), la gestion thermique, la d\u00e9tection, l\u2019extinction et la s\u00e9paration des sites.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d25dc7e5 auto-p elementor-widget elementor-widget-heading\" data-id=\"d25dc7e5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Pour toute d\u00e9cision d'achat en usine, exigez que le devis et la nomenclature pr\u00e9cisent le mod\u00e8le de cellule, la composition chimique de la cathode, l'architecture de l'\u00e9lectrolyte, l'\u00e9nergie nominale, l'\u00e9tendue des essais et les conditions de garantie. C'est ainsi que l'option ESSA \u00e0 \u00e9tat solide de MegSolid, sp\u00e9cifique \u00e0 chaque projet, peut \u00eatre \u00e9valu\u00e9e sans transposer les arguments marketing relatifs \u00e0 la cellule \u00e0 l'ensemble du syst\u00e8me de stockage d'\u00e9nergie par batterie (BESS).<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-580fe568 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"580fe568\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">\u00c9tape 5 : Pr\u00e9ciser le PPA ou la fourniture de services \u00e9nerg\u00e9tiques au PCC<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e54b1cd1 auto-p elementor-widget elementor-widget-heading\" data-id=\"e54b1cd1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Un syst\u00e8me de stockage d'\u00e9nergie par batterie (BESS) financ\u00e9 ou fourni dans le cadre d'un contrat de services \u00e9nerg\u00e9tiques doit fournir un service, et non pas simplement \u00eatre pr\u00e9sent sur site. Il convient de d\u00e9finir par contrat la plage horaire d'exploitation et les limites de r\u00e8glement : importation maximale vers le r\u00e9seau, puissance de d\u00e9charge disponible, \u00e9nergie livrable, r\u00e9serve de secours, source de charge autoris\u00e9e et \u00e9v\u00e9nements exclus. L'\u00e9talonnage des compteurs, l'acc\u00e8s aux donn\u00e9es et la m\u00e9thode de calcul de la disponibilit\u00e9 doivent \u00eatre convenus avant la conclusion de l'accord commercial.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d4c518f1 elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"d4c518f1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">\ud83d\udccc <strong>D\u00e9finition du service :<\/strong> Limitation des pics de consommation, fen\u00eatre de secours, d\u00e9calage de la consommation solaire ou une combinaison de ces mesures.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">\ud83e\uddee <strong>Indicateur de r\u00e8glement :<\/strong> kW et kWh au compteur convenu, avec intervalle et fuseau horaire.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">\ud83d\udd12 <strong>SOC r\u00e9serv\u00e9 :<\/strong> \u00c9nergie r\u00e9serv\u00e9e en cas de coupure de courant par rapport \u00e0 l'\u00e9nergie disponible pour l'optimisation tarifaire.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">\ud83d\udcc5 <strong>Disponibilit\u00e9 :<\/strong> Heures incluses, maintenance programm\u00e9e, coupures du r\u00e9seau, d\u00e9clenchements dus au site et cas de force majeure.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">\ud83e\uddfe <strong>Solution :<\/strong> D\u00e9lai de rectification, nouveau contr\u00f4le, augmentation, cr\u00e9dit de service ou toute autre mesure convenue.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">\ud83d\udd04 <strong>Contr\u00f4le des modifications :<\/strong> Prise en compte des charges suppl\u00e9mentaires, de l'augmentation de la puissance photovolta\u00efque, des modifications tarifaires et des nouveaux modes de fonctionnement.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-bda31200 auto-p elementor-widget elementor-widget-heading\" data-id=\"bda31200\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">GreenCape consid\u00e8re le stockage par batterie \u00ab derri\u00e8re le compteur \u00bb comme une opportunit\u00e9 pour les secteurs commercial, industriel et agricole sud-africains, la cr\u00e9ation de valeur ajout\u00e9e et la s\u00e9curit\u00e9 \u00e9nerg\u00e9tique constituant des facteurs d\u00e9terminants. Utilisez le <strong><a href=\"https:\/\/greencape.co.za\/wp-content\/uploads\/2025\/04\/Energy-Services-2025.pdf\" target=\"_blank\" style=\"color:#61CE70\" rel=\"noopener\">Rapport d'analyse du march\u00e9 des services \u00e9nerg\u00e9tiques 2025<\/a><\/strong> pour le contexte du march\u00e9, mais calculez l'analyse de rentabilit\u00e9 \u00e0 partir du tarif actuel de l'usine, de la charge mesur\u00e9e et des contraintes r\u00e9elles de r\u00e9partition.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-fe367e11 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"fe367e11\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Param\u00e8tres de l'appel d'offres EPC permettant d'obtenir des devis comparables<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-fba45eee auto-p elementor-widget elementor-widget-heading\" data-id=\"fba45eee\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Un appel d'offres de grande valeur d\u00e9finit clairement les hypoth\u00e8ses, de sorte que les fournisseurs ne puissent pas remporter le march\u00e9 en excluant les obligations en mati\u00e8re de protection, de contr\u00f4les, de mise en service ou d'\u00e9nergie utilisable. Envoyez un dossier d'information unique et exigez un calendrier de mise en conformit\u00e9 r\u00e9pertoriant chaque \u00e9cart. Le <strong><a href=\"https:\/\/www.solidess.com\/fr\/afrique-du-sud-citations-erronees-de-bess\/\" target=\"_blank\" style=\"color:#61CE70\">Guide en cas d'\u00e9chec de la cotation BESS en Afrique du Sud<\/a><\/strong> comble les lacunes commerciales qui apparaissent souvent apr\u00e8s la fixation des prix de r\u00e9f\u00e9rence.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-95c5780c auto-table elementor-widget elementor-widget-text-editor\" data-id=\"95c5780c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"cea-table-wrap\"><table><thead><tr><th>Rubrique \u00ab Appel d'offres \u00bb<\/th><th>Contribution minimale de l'acheteur<\/th><th>R\u00e9ponse du fournisseur requise<\/th><\/tr><\/thead><tbody><tr><td>Charge et tarif<\/td><td>12 mois de donn\u00e9es d'intervalle, de factures, de NMD, de p\u00e9riodes tarifaires et de plan d'extension<\/td><td>Mod\u00e8le de dimensionnement, \u00e9v\u00e9nements exclus et profil de r\u00e9partition pr\u00e9vu<\/td><\/tr><tr><td>Interface \u00e9lectrique<\/td><td>SLD, tension, fr\u00e9quence, transformateur, niveau de d\u00e9faut, mise \u00e0 la terre et protection<\/td><td>Indice PCS, appareillage de commutation, p\u00e9rim\u00e8tre d'\u00e9tude de protection et pertes<\/td><\/tr><tr><td>Service op\u00e9rationnel<\/td><td>Pointe de consommation, charges de secours, dur\u00e9e de fonctionnement, \u00e9nergie photovolta\u00efque, groupe \u00e9lectrog\u00e8ne et limite d'exportation<\/td><td>Puissance garantie, \u00e9nergie utilisable, r\u00e9serve SOC et hi\u00e9rarchie des modes<\/td><\/tr><tr><td>Environnement<\/td><td>Conditions ambiantes, altitude, poussi\u00e8re, corrosion, risque d'inondation, acc\u00e8s et limites acoustiques<\/td><td>D\u00e9classement, enceinte, refroidissement, agencement et espaces libres pour l'entretien<\/td><\/tr><tr><td>Commandes et donn\u00e9es<\/td><td>Compteur PCC, propri\u00e9taire du syst\u00e8me EMS, protocole SCADA, cybers\u00e9curit\u00e9 et conservation des donn\u00e9es<\/td><td>Narration de contr\u00f4le, carte des registres, liste des alarmes et comportement de s\u00e9curit\u00e9 int\u00e9gr\u00e9e<\/td><\/tr><tr><td>S\u00e9curit\u00e9 et conformit\u00e9<\/td><td>Autorit\u00e9 comp\u00e9tente, strat\u00e9gie de lutte contre les incendies et \u00e9tendue des documents requis<\/td><td>Rapports relatifs aux cellules et aux syst\u00e8mes, d\u00e9tection, suppression, interventions d'urgence et \u00e9carts<\/td><\/tr><tr><td>R\u00e9ception et garantie<\/td><td>FAT, SAT, test de capacit\u00e9, disponibilit\u00e9, d\u00e9bit et objectif de fin de vie (EOL)<\/td><td>Proc\u00e9dures d'essai, seuils de conformit\u00e9, mesures correctives, exclusions et pi\u00e8ces de rechange<\/td><\/tr><tr><td>Livraison commerciale<\/td><td>Lieu, Incoterm, date de livraison, r\u00e9partition des travaux d'installation et assistance locale<\/td><td>\u00c9tapes cl\u00e9s relatives aux \u00e9l\u00e9ments inclus, aux d\u00e9lais de livraison, \u00e0 la mise en service, \u00e0 la formation et au paiement<\/td><\/tr><\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-dc9cd897 auto-p elementor-widget elementor-widget-heading\" data-id=\"dc9cd897\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Avant de lancer les travaux, v\u00e9rifiez les exigences locales en mati\u00e8re de raccordement ainsi que la proc\u00e9dure d'autorisation du distributeur comp\u00e9tent. Le <strong><a href=\"https:\/\/www.solidess.com\/fr\/reglementation-relative-au-bess-en-afrique-du-sud\/\" target=\"_blank\" style=\"color:#61CE70\">Guide sur la r\u00e9glementation sud-africaine relative aux syst\u00e8mes de stockage d'\u00e9nergie par batterie (BESS)<\/a><\/strong> Il s'agit d'une liste de contr\u00f4le initiale qui ne saurait se substituer \u00e0 des conseils juridiques, techniques ou d'ing\u00e9nierie sp\u00e9cifiques au projet.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ace760b4 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"ace760b4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Informations \u00e0 fournir \u00e0 MegSolid pour obtenir une estimation pr\u00e9liminaire de la taille du syst\u00e8me BESS<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-df515b15 elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"df515b15\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">\ud83d\udcca Douze mois de donn\u00e9es de charge (par tranches de 15 ou 30 minutes) au format tableur.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">\ud83e\uddfe Factures r\u00e9centes indiquant le tarif, le NMD, la consommation et les frais li\u00e9s aux tranches horaires.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">\u2699\ufe0f Liste des charges critiques, s\u00e9quence de fonctionnement, caract\u00e9ristiques nominales des moteurs et plage de secours requise.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">\u2600\ufe0f Puissance photovolta\u00efque existante ou pr\u00e9vue, profil, caract\u00e9ristiques des onduleurs et limite d'injection.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">\u26fd Mod\u00e8le du g\u00e9n\u00e9rateur, puissance nominale, interface de commande et contraintes de charge minimale.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">\ud83d\udd0c Sch\u00e9ma unifilaire actuel, tension d'alimentation, emplacement du transformateur et du compteur PCC.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">\ud83c\udf21\ufe0f Altitude du site, plage de temp\u00e9rature ambiante, conditions de poussi\u00e8re et de corrosion, et encombrement disponible.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">\ud83d\udcc5 Date de livraison pr\u00e9vue, Incoterm, r\u00e9partition des co\u00fbts de mise en service et dur\u00e9e de garantie requise.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-19756322 auto-p elementor-widget elementor-widget-heading\" data-id=\"19756322\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">MegSolid can use this pack to return a preliminary kW\/kWh range, suitable product direction, EMS boundary and missing-data list. Final selection remains subject to load validation, protection and power-quality studies, local approvals, project-specific datasheets, commercial terms and the approved single-line diagram. Start the equipment screen with the <a href=\"https:\/\/www.solidess.com\/fr\/product\/systeme-de-stockage-denergie-en-armoire-exterieure\/\">ESSA outdoor cabinet specifications<\/a>, then compare the required power and discharge window with the model returned in your sizing review.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6259cbce elementor-tablet-align-center elementor-align-center auto-cta elementor-widget elementor-widget-button\" data-id=\"6259cbce\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"#elementor-action%3Aaction%3Dpopup%3Aopen%26settings%3DeyJpZCI6Ijk0OCIsInRvZ2dsZSI6ZmFsc2V9\" target=\"_blank\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Obtenir une estimation pr\u00e9liminaire de la taille de mon syst\u00e8me BESS d'usine<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-93643999 auto-p elementor-widget elementor-widget-heading\" data-id=\"93643999\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Cet article ne fournit qu'un cadre pr\u00e9liminaire de dimensionnement. Pour obtenir l'outil Excel complet de dimensionnement BESS, les limites pr\u00e9liminaires du sch\u00e9ma unifilaire et la matrice de demande de devis pour le syst\u00e8me de gestion de l'\u00e9nergie (EMS), envoyez un e-mail \u00e0 <strong><a href=\"mailto:sfhq2008@gmail.com\" style=\"color:#61CE70\">sfhq2008@gmail.com<\/a><\/strong>.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ea63e2f2 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"ea63e2f2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Factory Sizing and Procurement Questions<\/h2>\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-bcb39722 auto-faq e-flex e-con-boxed e-con e-child\" data-id=\"bcb39722\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-4dbcac74 elementor-widget elementor-widget-heading\" data-id=\"4dbcac74\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">FAQ<\/h2>\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-fac9d9d2 e-con-full e-flex e-con e-child\" data-id=\"fac9d9d2\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-e1ca1f27 elementor-widget elementor-widget-n-accordion\" data-id=\"e1ca1f27\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;default_state&quot;:&quot;all_collapsed&quot;,&quot;max_items_expended&quot;:&quot;one&quot;,&quot;n_accordion_animation_duration&quot;:{&quot;unit&quot;:&quot;ms&quot;,&quot;size&quot;:400,&quot;sizes&quot;:[]}}\" data-widget_type=\"nested-accordion.default\">\n\t\t\t\t\t\t\t<div class=\"e-n-accordion\" aria-label=\"Accord\u00e9on. Ouvrez les liens \u00e0 l&#039;aide de la touche Entr\u00e9e ou de la barre d&#039;espace, fermez-les avec la touche \u00c9chap et naviguez \u00e0 l&#039;aide des touches fl\u00e9ch\u00e9es.\">\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-3780\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"1\" tabindex=\"0\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-3780\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Quelles sont les donn\u00e9es n\u00e9cessaires pour d\u00e9terminer la capacit\u00e9 d'un syst\u00e8me de stockage par batterie \u00e0 usage commercial destin\u00e9 \u00e0 une usine ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3780\" class=\"elementor-element elementor-element-8e35f71a e-con-full e-flex e-con e-child\" data-id=\"8e35f71a\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3780\" class=\"elementor-element elementor-element-1c4a0aa0 e-con-full e-flex e-con e-child\" data-id=\"1c4a0aa0\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-533ee4bd elementor-widget elementor-widget-heading\" data-id=\"533ee4bd\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Veuillez fournir au moins 12 mois de donn\u00e9es de charge par intervalle, les factures r\u00e9centes et le tarif applicable, les plannings des charges critiques, les caract\u00e9ristiques des moteurs, les informations relatives aux installations photovolta\u00efques et aux g\u00e9n\u00e9rateurs, un sch\u00e9ma unifilaire, les conditions du site et les modes de fonctionnement requis.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-3781\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"2\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-3781\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Quelle est la diff\u00e9rence entre les kW et les kWh du syst\u00e8me BESS ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3781\" class=\"elementor-element elementor-element-e2fcbde2 e-con-full e-flex e-con e-child\" data-id=\"e2fcbde2\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3781\" class=\"elementor-element elementor-element-4b9b2efe e-con-full e-flex e-con e-child\" data-id=\"4b9b2efe\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-3a4cecf9 elementor-widget elementor-widget-heading\" data-id=\"3a4cecf9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Le kW correspond \u00e0 la puissance alternative instantan\u00e9e que le syst\u00e8me peut fournir ou absorber. Le kWh correspond \u00e0 l'\u00e9nergie consomm\u00e9e au fil du temps. Une usine a besoin d'une puissance en kW suffisante pour couvrir le plus grand \u00e9cart de charge contr\u00f4l\u00e9 et d'une quantit\u00e9 suffisante de kWh utilisables pour maintenir ce niveau de fonctionnement pendant la dur\u00e9e pr\u00e9vue.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-3782\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"3\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-3782\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Comment calcule-t-on l'autonomie de la batterie de secours d'usine ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3782\" class=\"elementor-element elementor-element-db60357d e-con-full e-flex e-con e-child\" data-id=\"db60357d\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3782\" class=\"elementor-element elementor-element-37b6b805 e-con-full e-flex e-con e-child\" data-id=\"37b6b805\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a4073629 elementor-widget elementor-widget-heading\" data-id=\"a4073629\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Multipliez la charge critique variable dans le temps par le nombre d'heures n\u00e9cessaires pour obtenir l'\u00e9nergie CA utilisable, puis divisez le r\u00e9sultat par un facteur sp\u00e9cifique au projet tenant compte de la profondeur de d\u00e9charge (DOD) autoris\u00e9e, des pertes, des \u00e9quipements auxiliaires, de la r\u00e9serve et des hypoth\u00e8ses relatives au vieillissement.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-3783\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"4\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-3783\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Un m\u00eame syst\u00e8me de stockage d'\u00e9nergie par batterie (BESS) peut-il assurer \u00e0 la fois l'\u00e9cr\u00eatement des pics de consommation et la fonction de secours ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3783\" class=\"elementor-element elementor-element-4157809b e-con-full e-flex e-con e-child\" data-id=\"4157809b\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3783\" class=\"elementor-element elementor-element-aeadae8e e-con-full e-flex e-con e-child\" data-id=\"aeadae8e\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-f3218c58 elementor-widget elementor-widget-heading\" data-id=\"f3218c58\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Oui, \u00e0 condition que l'alimentation PCS et l'\u00e9nergie de la batterie puissent prendre en charge les deux fonctions et que le syst\u00e8me EMS prot\u00e8ge la r\u00e9serve SOC de secours. L'appel d'offres doit pr\u00e9ciser quel service a la priorit\u00e9 lorsque les deux ont besoin d'\u00e9nergie.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-3784\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"5\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-3784\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> La capacit\u00e9 de la batterie doit-elle correspondre \u00e0 la capacit\u00e9 photovolta\u00efque de l'usine ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3784\" class=\"elementor-element elementor-element-2e7474a3 e-con-full e-flex e-con e-child\" data-id=\"2e7474a3\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3784\" class=\"elementor-element elementor-element-44aa9670 e-con-full e-flex e-con e-child\" data-id=\"44aa9670\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-247e7673 elementor-widget elementor-widget-heading\" data-id=\"247e7673\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Non. La capacit\u00e9 de stockage d\u00e9pend de l\u2019exc\u00e9dent photovolta\u00efque mesur\u00e9, de la charge ult\u00e9rieure, des contraintes d\u2019exportation et de la fen\u00eatre de r\u00e9gulation. La puissance nominale photovolta\u00efque en kWp ne suffit pas \u00e0 elle seule \u00e0 d\u00e9terminer la capacit\u00e9 requise de la batterie en kW ou en kWh.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-3785\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"6\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-3785\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Un syst\u00e8me BESS d'usine peut-il fonctionner avec un groupe \u00e9lectrog\u00e8ne diesel ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3785\" class=\"elementor-element elementor-element-ab638597 e-con-full e-flex e-con e-child\" data-id=\"ab638597\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3785\" class=\"elementor-element elementor-element-98f93821 e-con-full e-flex e-con e-child\" data-id=\"98f93821\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-3c0f2b6b elementor-widget elementor-widget-heading\" data-id=\"3c0f2b6b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">C'est possible lorsque l'architecture \u00e9lectrique et les commandes sont con\u00e7ues \u00e0 cet effet. Il convient de d\u00e9finir les responsabilit\u00e9s en mati\u00e8re de formation du r\u00e9seau, la logique de d\u00e9marrage et d'arr\u00eat du g\u00e9n\u00e9rateur, la charge minimale, l'autorisation de charge, la synchronisation et la protection.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-3786\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"7\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-3786\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Est-ce que toutes les armoires MegSolid ESSA sont des syst\u00e8mes de stockage d'\u00e9nergie \u00e0 semi-conducteurs (BESS) ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3786\" class=\"elementor-element elementor-element-3f753a66 e-con-full e-flex e-con e-child\" data-id=\"3f753a66\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3786\" class=\"elementor-element elementor-element-38e089fb e-con-full e-flex e-con e-child\" data-id=\"38e089fb\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-acbbdb80 elementor-widget elementor-widget-heading\" data-id=\"acbbdb80\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Non. Le tableau ESSA publi\u00e9 r\u00e9pertorie les cellules LFP. MegSolid confirme que des configurations de cellules \u00e0 l'\u00e9tat solide sp\u00e9cifiques \u00e0 chaque projet sont disponibles, mais le mod\u00e8le de cellule command\u00e9, l'architecture de l'\u00e9lectrolyte, la nomenclature et la garantie doivent pr\u00e9ciser ce qui est fourni.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-3787\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"8\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-3787\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Une batterie \u00e0 \u00e9tat solide \u00e9limine-t-elle le risque d'emballement thermique ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3787\" class=\"elementor-element elementor-element-65edfba9 e-con-full e-flex e-con e-child\" data-id=\"65edfba9\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3787\" class=\"elementor-element elementor-element-9e45d776 e-con-full e-flex e-con e-child\" data-id=\"9e45d776\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-d39267f1 elementor-widget elementor-widget-heading\" data-id=\"d39267f1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Aucun fournisseur responsable ne devrait faire une affirmation aussi cat\u00e9gorique. Une architecture \u00e0 semi-conducteurs certifi\u00e9e peut certes r\u00e9duire certains risques, mais la s\u00e9curit\u00e9 globale du syst\u00e8me d\u00e9pend toujours des cellules, du syst\u00e8me de gestion de la batterie (BMS), du syst\u00e8me de contr\u00f4le de puissance (PCS), de la gestion thermique, des dispositifs de d\u00e9tection et d'extinction, ainsi que de l'installation et de l'exploitation.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-3788\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"9\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-3788\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Une usine devrait-elle opter pour un syst\u00e8me MegSolid de 215,04 kWh ou de 261,24 kWh ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3788\" class=\"elementor-element elementor-element-e7b4babb e-con-full e-flex e-con e-child\" data-id=\"e7b4babb\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3788\" class=\"elementor-element elementor-element-d3fb9286 e-con-full e-flex e-con e-child\" data-id=\"d3fb9286\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-2f01d49c elementor-widget elementor-widget-heading\" data-id=\"2f01d49c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Comparez la puissance \u00e9lectrique CA requise, l'\u00e9nergie utilisable, le refroidissement, la temp\u00e9rature du site, l'encombrement et l'int\u00e9gration. Le mod\u00e8le ESSA0100B-0215 a une puissance nominale de 100 kW \/ 215,04 kWh avec refroidissement par air intelligent ; le syst\u00e8me de 261,24 kWh a une puissance nominale de 125 kVA avec refroidissement par liquide. Le choix final n\u00e9cessite les donn\u00e9es du projet.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-3789\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"10\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-3789\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Que doit comporter un devis EPC BESS ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3789\" class=\"elementor-element elementor-element-4416ddf6 e-con-full e-flex e-con e-child\" data-id=\"4416ddf6\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3789\" class=\"elementor-element elementor-element-eb9d515c e-con-full e-flex e-con e-child\" data-id=\"eb9d515c\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-d1fa959b elementor-widget elementor-widget-heading\" data-id=\"d1fa959b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Exiger la description compl\u00e8te du champ d'application CA et CC, la base d'\u00e9nergie utilisable, le syst\u00e8me de conversion d'\u00e9nergie (PCS), la batterie, le syst\u00e8me de gestion de l'\u00e9nergie (EMS), l'appareillage de commutation, les dispositifs de protection, le refroidissement, la strat\u00e9gie de lutte contre l'incendie, les communications, les essais d'acceptation sur site (FAT) et sur site chez le client (SAT), la mise en service, la garantie, les pi\u00e8ces de rechange, les exclusions, les Incoterms et le calendrier de livraison.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-37810\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"11\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-37810\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> De quelle capacit\u00e9 de stockage par batterie \u00e0 usage commercial une usine sud-africaine a-t-elle besoin ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-37810\" class=\"elementor-element elementor-element-fd8414b4 e-con-full e-flex e-con e-child\" data-id=\"fd8414b4\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-37810\" class=\"elementor-element elementor-element-c1d31a15 e-con-full e-flex e-con e-child\" data-id=\"c1d31a15\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-7cd0312a elementor-widget elementor-widget-heading\" data-id=\"7cd0312a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Il n'existe pas de estimation fiable de la puissance n\u00e9cessaire bas\u00e9e uniquement sur la consommation mensuelle. Il convient de calculer l'\u00e9cart de puissance maximal contr\u00f4l\u00e9 (en kW) et la plage de fonctionnement requise, puis de prendre en compte les pertes, la r\u00e9serve, les transitoires, les r\u00e8gles tarifaires, les conditions du site et les extensions futures.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-37811\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"12\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-37811\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Quel est le meilleur syst\u00e8me de stockage par batterie pour une usine sud-africaine ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-37811\" class=\"elementor-element elementor-element-ad9987a7 e-con-full e-flex e-con e-child\" data-id=\"ad9987a7\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-37811\" class=\"elementor-element elementor-element-687b0133 e-con-full e-flex e-con e-child\" data-id=\"687b0133\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-2c9fc29d elementor-widget elementor-widget-heading\" data-id=\"2c9fc29d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Le meilleur syst\u00e8me est celui qui r\u00e9pond aux exigences v\u00e9rifi\u00e9es de la centrale en mati\u00e8re de puissance, d'\u00e9nergie utile, d'environnement, de s\u00e9curit\u00e9, de contr\u00f4le et de fourniture commerciale au point de mesure convenu. Les justificatifs fournis par le fournisseur et le p\u00e9rim\u00e8tre du contrat EPC ont autant d'importance que la puissance nominale.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-37812\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"13\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-37812\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Comment une usine sud-africaine peut-elle demander un devis pour le syst\u00e8me MegSolid BESS ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-37812\" class=\"elementor-element elementor-element-42644d02 e-con-full e-flex e-con e-child\" data-id=\"42644d02\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-37812\" class=\"elementor-element elementor-element-38c55c77 e-con-full e-flex e-con e-child\" data-id=\"38c55c77\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-790fb49f elementor-widget elementor-widget-heading\" data-id=\"790fb49f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Envoyez les donn\u00e9es relatives aux intervalles de charge, les factures et les tarifs, le calendrier des charges critiques, la dur\u00e9e de l'alimentation de secours, les informations sur les installations photovolta\u00efques et les g\u00e9n\u00e9rateurs, le SLD, les conditions du site, la date de livraison et les limites commerciales \u00e0 l'adresse sfhq2008@gmail.com ou utilisez la page de contact de MegSolid.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Guide pratique sud-africain pour le dimensionnement des syst\u00e8mes BESS, couvrant les kW, les kWh, l'autonomie de secours, l'\u00e9cr\u00eatement des pics de consommation, les priorit\u00e9s du syst\u00e8me de gestion de l'\u00e9nergie (EMS), l'ad\u00e9quation des produits et les informations n\u00e9cessaires pour les appels d'offres (RFQ) conformes aux normes EPC.<\/p>","protected":false},"author":4,"featured_media":4476,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"_joinchat":[],"footnotes":""},"categories":[1],"tags":[218,217,213,216,214,215,212],"class_list":["post-4479","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-bess","tag-bess-ems","tag-ci-bess-sizing","tag-commercial-battery-storage-south-africa","tag-factory-battery-backup-system","tag-factory-battery-storage-system","tag-industrial-battery-storage-south-africa","tag-megsolid-bess"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/posts\/4479","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/comments?post=4479"}],"version-history":[{"count":6,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/posts\/4479\/revisions"}],"predecessor-version":[{"id":6104,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/posts\/4479\/revisions\/6104"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/media\/4476"}],"wp:attachment":[{"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/media?parent=4479"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/categories?post=4479"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/tags?post=4479"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}