{"id":4537,"date":"2026-08-05T15:43:37","date_gmt":"2026-08-05T07:43:37","guid":{"rendered":"https:\/\/www.solidess.com\/?p=4537"},"modified":"2026-10-08T17:57:23","modified_gmt":"2026-10-08T09:57:23","slug":"usine-dimpression-nigeria-fabricant-bess-1000kwh-ddc","status":"publish","type":"post","link":"https:\/\/www.solidess.com\/fr\/nigeria-printing-factory-bess-manufacturer-1000kwh-rfq\/","title":{"rendered":"Guide du fabricant de BESS pour une imprimerie au Nigeria : pr\u00e9parer une demande de devis pour un syst\u00e8me de 1 000 kWh en secours ou hors r\u00e9seau"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"4537\" class=\"elementor elementor-4537\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-bf4793c e-con-full auto-article-root e-flex e-con e-parent\" data-id=\"bf4793c\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-fb8a29a3 auto-p elementor-widget elementor-widget-heading\" data-id=\"fb8a29a3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Une imprimerie nig\u00e9riane qui envisage environ 1 000 kWh de stockage d\u2019\u00e9nergie pour le secours ou le fonctionnement hors r\u00e9seau devrait commencer par constituer un dossier technique avant de choisir d\u00e9finitivement les \u00e9quipements. <strong><a href=\"https:\/\/www.solidess.com\/fr\/a-propos-de-megsolid\/\" target=\"_blank\" style=\"color:#61CE70\">MegSolid Technology Co., Ltd.<\/a><\/strong>, qui exerce ses activit\u00e9s sous la marque SolidESS, fournit des batteries hybrides \u00e0 l\u2019\u00e9tat solide, des syst\u00e8mes de stockage d\u2019\u00e9nergie commerciaux et industriels et des \u00e9quipements de conversion de puissance aux entreprises EPC, aux distributeurs et aux ma\u00eetres d\u2019ouvrage. Avant de demander une configuration compl\u00e8te et un devis usine, il convient d\u2019\u00e9tablir la charge de l\u2019usine, la puissance requise c\u00f4t\u00e9 courant alternatif, le r\u00e9gime de fonctionnement, les \u00e9quipements \u00e9nerg\u00e9tiques existants, les conditions du site et le p\u00e9rim\u00e8tre de livraison.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-bf874e72 elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"bf874e72\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>Confirmer d\u2019abord la puissance requise :<\/strong> La mention \u00ab 1 000 kWh \u00bb ne pr\u00e9cise pas la puissance en kW ou en kVA que l'usine doit pouvoir prendre en charge.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>D\u00e9finir le cycle de fonctionnement :<\/strong> La dur\u00e9e d\u2019alimentation de secours, le fonctionnement quotidien et la priorit\u00e9 des charges critiques influent sur le dimensionnement du syst\u00e8me.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>Veillez \u00e0 ce que les preuves soient sp\u00e9cifiques au mod\u00e8le :<\/strong> Utilisez dans chaque comparaison technique la r\u00e9f\u00e9rence exacte du mod\u00e8le, la valeur indiqu\u00e9e dans la source et la condition \u00e0 laquelle elle s\u2019applique.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>Dissocier l'approvisionnement de la r\u00e9alisation du projet :<\/strong> La fourniture des \u00e9quipements, leur installation, les travaux de g\u00e9nie civil et la mise en service peuvent relever de diff\u00e9rentes entit\u00e9s responsables.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>Demander des justificatifs :<\/strong> Comparez les nomenclatures, les plans, les certificats, les plans d\u2019essai, les conditions de garantie et les exclusions avant de vous engager.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0e7ab35d auto-p elementor-widget elementor-widget-heading\" data-id=\"0e7ab35d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Ce guide sert \u00e0 pr\u00e9parer l\u2019achat et ne constitue pas un compte rendu de mise en service dans l\u2019usine envisag\u00e9e. Le descriptif du projet confirme le pays, l\u2019application d\u2019impression industrielle, l\u2019utilisation pr\u00e9vue en secours ou hors r\u00e9seau et la demande pr\u00e9liminaire de 1 000 kWh de capacit\u00e9. La puissance de pointe, la dur\u00e9e de fonctionnement quotidienne, les caract\u00e9ristiques de l\u2019installation photovolta\u00efque et du groupe \u00e9lectrog\u00e8ne diesel, le lieu d\u2019installation, l\u2019altitude, la configuration du raccordement au r\u00e9seau et les modalit\u00e9s d\u2019injection n\u2019ont pas \u00e9t\u00e9 communiqu\u00e9s. Ces \u00e9l\u00e9ments devraient rester clairement signal\u00e9s comme des donn\u00e9es que l\u2019acheteur doit confirmer.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b61a6c92 elementor-tablet-align-center elementor-align-center auto-cta elementor-widget elementor-widget-button\" data-id=\"b61a6c92\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"#elementor-action%3Aaction%3Dpopup%3Aopen%26settings%3DeyJpZCI6Ijk0OCIsInRvZ2dsZSI6ZmFsc2V9\" target=\"_blank\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Demander au fabricant de BESS une consultation sur le projet<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-610082c9 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"610082c9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">La capacit\u00e9 \u00e9nerg\u00e9tique ne suffit pas \u00e0 elle seule \u00e0 d\u00e9finir le syst\u00e8me des imprimeries<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9311bc23 auto-image elementor-widget elementor-widget-image\" data-id=\"9311bc23\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"1536\" height=\"864\" src=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/07\/bess-factory-acceptance-testing-1536x864.jpg\" class=\"attachment-1536x1536 size-1536x1536 wp-image-4137\" alt=\"Des ing\u00e9nieurs effectuant des essais de r\u00e9ception en usine sur une armoire de stockage de batteries \u00e0 usage commercial\" srcset=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/07\/bess-factory-acceptance-testing-1536x864.jpg 1536w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/07\/bess-factory-acceptance-testing-300x169.jpg 300w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/07\/bess-factory-acceptance-testing-1024x576.jpg 1024w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/07\/bess-factory-acceptance-testing-768x432.jpg 768w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/07\/bess-factory-acceptance-testing-600x338.jpg 600w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/07\/bess-factory-acceptance-testing.jpg 1672w\" sizes=\"(max-width: 1536px) 100vw, 1536px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6d9728b2 auto-p elementor-widget elementor-widget-heading\" data-id=\"6d9728b2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">La capacit\u00e9 \u00e9nerg\u00e9tique s\u2019exprime en kilowattheures, tandis que l\u2019aptitude \u00e0 r\u00e9pondre \u00e0 la demande \u00e9lectrique instantan\u00e9e s\u2019exprime en kilowatts ou en kilovoltamp\u00e8res. Un syst\u00e8me de batteries dont l\u2019objectif \u00e9nerg\u00e9tique est d\u00e9fini peut ne pas convenir si les \u00e9quipements de conversion de puissance ne peuvent pas prendre en charge la charge de fonctionnement, les contraintes de d\u00e9marrage des moteurs ou la s\u00e9quence retenue pour les charges critiques. \u00c0 l\u2019inverse, une puissance \u00e9lev\u00e9e c\u00f4t\u00e9 courant alternatif ne suffit pas \u00e0 d\u00e9terminer la dur\u00e9e pendant laquelle l\u2019usine peut fonctionner lors d\u2019une coupure.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a168f2d3 auto-p elementor-widget elementor-widget-heading\" data-id=\"a168f2d3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Cette distinction est importante dans le domaine de l'impression industrielle. La demande \u00e9lectrique peut varier entre les \u00e9quipements de production, les processus de s\u00e9chage, les compresseurs d'air, l'\u00e9clairage, les charges informatiques, la manutention des mat\u00e9riaux et d'autres services de l'usine. Les informations disponibles sur le projet ne fournissent pas de donn\u00e9es sur les charges par intervalle ni de calendrier des charges critiques. Il serait inappropri\u00e9 de supposer que l'ensemble de l'installation doit fonctionner \u00e0 partir du stockage, ou que seules certaines charges s\u00e9lectionn\u00e9es n\u00e9cessitent une continuit\u00e9 d'alimentation.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b330816d auto-p elementor-widget elementor-widget-heading\" data-id=\"b330816d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">L\u2019\u00e9quipe charg\u00e9e des achats devrait pr\u00e9ciser ce que repr\u00e9sentent les 1 000 kWh. Il peut s\u2019agir d\u2019un objectif pr\u00e9liminaire d\u2019\u00e9nergie nominale de la batterie, d\u2019un objectif d\u2019\u00e9nergie utilisable \u00e0 fournir c\u00f4t\u00e9 courant alternatif ou d\u2019une valeur de planification commerciale. Ces mesures sont diff\u00e9rentes. L\u2019\u00e9nergie d\u00e9livr\u00e9e c\u00f4t\u00e9 courant alternatif peut d\u00e9pendre de l\u2019architecture choisie, des limites de fonctionnement, de la consommation des auxiliaires, de la strat\u00e9gie de commande et des conditions d\u2019exploitation. <strong>Informations non disponibles dans les fichiers source actuels de MegSolid :<\/strong> une valeur garantie d\u2019\u00e9nergie utilisable c\u00f4t\u00e9 courant alternatif pour ce projet pr\u00e9cis d\u2019imprimerie au Nigeria.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8fb70f4d auto-h2 elementor-widget elementor-widget-heading\" data-id=\"8fb70f4d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Utilisez un questionnaire technique en six parties avant de demander un devis d\u00e9finitif<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-942b9f84 auto-image elementor-widget elementor-widget-image\" data-id=\"942b9f84\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"1448\" height=\"1086\" src=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/07\/megsolid-understanding-solid-state-battery-technologies-guide.jpg\" class=\"attachment-1536x1536 size-1536x1536 wp-image-3953\" alt=\"Infographie comparant les technologies de batteries : elle met en \u00e9vidence les diff\u00e9rences entre les structures d&#039;\u00e9lectrolytes conventionnelles au lithium-ion, \u00e0 gel semi-solide, hybrides \u00e0 l&#039;\u00e9tat solide et enti\u00e8rement \u00e0 l&#039;\u00e9tat solide, ainsi que leur maturit\u00e9 commerciale.\" srcset=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/07\/megsolid-understanding-solid-state-battery-technologies-guide.jpg 1448w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/07\/megsolid-understanding-solid-state-battery-technologies-guide-300x225.jpg 300w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/07\/megsolid-understanding-solid-state-battery-technologies-guide-1024x768.jpg 1024w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/07\/megsolid-understanding-solid-state-battery-technologies-guide-768x576.jpg 768w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/07\/megsolid-understanding-solid-state-battery-technologies-guide-600x450.jpg 600w\" sizes=\"(max-width: 1448px) 100vw, 1448px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-404582d7 auto-p elementor-widget elementor-widget-heading\" data-id=\"404582d7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Utilisez le questionnaire en six parties ci-dessous avant de demander \u00e0 un <em>fabricant de BESS<\/em> un devis final complet. Ce questionnaire transforme une demande pr\u00e9liminaire de capacit\u00e9 en dossier technique que peuvent examiner l\u2019usine, une entreprise EPC locale et le fournisseur d\u2019\u00e9quipements pressenti. Il r\u00e9duit aussi le risque que les soumissionnaires chiffrent des p\u00e9rim\u00e8tres diff\u00e9rents tout en affichant des capacit\u00e9s globales similaires.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3540dcfe auto-table elementor-widget elementor-widget-text-editor\" data-id=\"3540dcfe\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"cea-table-wrap\"><table><tbody><\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-21cd6dc8 auto-p elementor-widget elementor-widget-heading\" data-id=\"21cd6dc8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Attachez une attention particuli\u00e8re \u00e0 la liste des charges critiques. L\u2019usine devrait pr\u00e9ciser quelles charges doivent rester imm\u00e9diatement sous tension, lesquelles peuvent \u00eatre r\u00e9tablies par \u00e9tapes et lesquelles peuvent \u00eatre d\u00e9lest\u00e9es. C\u2019est autant une d\u00e9cision d\u2019exploitation qu\u2019un choix d\u2019\u00e9quipements. Elle d\u00e9termine si le syst\u00e8me doit assurer la continuit\u00e9 des activit\u00e9s de production essentielles ou prendre en charge une plus grande partie de l\u2019usine.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-80ad9a58 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"80ad9a58\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">D\u00e9finir la puissance c\u00f4t\u00e9 courant alternatif et la dur\u00e9e avant de comparer les blocs de batteries<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-57e295a5 auto-p elementor-widget elementor-widget-heading\" data-id=\"57e295a5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Commencez par d\u00e9terminer la puissance requise c\u00f4t\u00e9 courant alternatif et la dur\u00e9e n\u00e9cessaire \u00e0 cette charge, puis examinez l\u2019\u00e9nergie de la batterie, la compatibilit\u00e9 du PCS, les commandes et l\u2019implantation. Cet ordre compte, car une demande de 1 000 kWh peut correspondre \u00e0 un fonctionnement prolong\u00e9 \u00e0 faible puissance ou \u00e0 des besoins de production qui exigent une puissance plus \u00e9lev\u00e9e. La seule capacit\u00e9 ne permet de d\u00e9duire ni l\u2019un ni l\u2019autre.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a4c34b17 auto-p elementor-widget elementor-widget-heading\" data-id=\"a4c34b17\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default translation-block\">Pour une premi\u00e8re \u00e9valuation, la documentation technique actuelle de MegSolid indique pour le mod\u00e8le <strong>ESSA0100B-0215<\/strong> <strong>une capacit\u00e9 nominale de 215,04 kWh<\/strong>, <strong>une puissance nominale de 100 kW c\u00f4t\u00e9 courant alternatif<\/strong> et <strong>une plage de tension de batterie de 672 \u00e0 850 V<\/strong>. Cette source indique un syst\u00e8me LFP \u00e0 refroidissement par air. Consultez la <strong><a href=\"https:\/\/www.solidess.com\/fr\/product\/systeme-de-stockage-denergie-en-armoire-exterieure\/\" target=\"_blank\" style=\"color:#61CE70\">page produit de l\u2019armoire ext\u00e9rieure MegSolid<\/a><\/strong> pour r\u00e9unir la documentation \u00e0 jour. Ces valeurs servent \u00e0 pr\u00e9s\u00e9lectionner ce mod\u00e8le et ne d\u00e9finissent pas une configuration pour l\u2019imprimerie nig\u00e9riane.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-325a1221 auto-p elementor-widget elementor-widget-heading\" data-id=\"325a1221\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">L\u2019acheteur ne devrait pas d\u00e9duire par simple division un nombre fixe d\u2019unit\u00e9s d\u2019une demande de 1 000 kWh. Ce calcul ne permet de d\u00e9terminer ni l\u2019\u00e9nergie utilisable, ni la puissance requise c\u00f4t\u00e9 courant alternatif, ni la consommation des auxiliaires, ni la redondance, ni le profil de charge, ni les contraintes impos\u00e9es \u00e0 l\u2019appareillage \u00e9lectrique, ni l\u2019implantation des enveloppes, ni l\u2019architecture des communications, ni l\u2019ad\u00e9quation au site. Une proposition \u00e0 plusieurs unit\u00e9s exige un sch\u00e9ma unifilaire du projet, une strat\u00e9gie de commande d\u00e9finie et un examen de l\u2019ensemble du p\u00e9rim\u00e8tre \u00e9lectrique et d\u2019installation.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6d22b0d6 auto-p elementor-widget elementor-widget-heading\" data-id=\"6d22b0d6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">MegSolid propose \u00e9galement une <strong><a href=\"https:\/\/www.solidess.com\/fr\/systeme-de-stockage-denergie-pour-armoire-dexterieur-megsolid\/\" target=\"_blank\" style=\"color:#61CE70\">cat\u00e9gorie des syst\u00e8mes de stockage d\u2019\u00e9nergie commerciaux en armoire ext\u00e9rieure<\/a><\/strong>. L\u2019armoire, le syst\u00e8me conteneuris\u00e9 ou une autre configuration ne devraient \u00eatre retenus qu\u2019apr\u00e8s avoir \u00e9tabli, dans l\u2019\u00e9tude, la charge r\u00e9elle, les conditions d\u2019acc\u00e8s, l\u2019emprise au sol, le mode de fonctionnement et les contraintes de l\u2019entreprise EPC. La disponibilit\u00e9 d\u2019une cat\u00e9gorie de produits ne prouve pas qu\u2019un syst\u00e8me donn\u00e9 r\u00e9pond aux exigences de cette usine.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-15bf6aeb auto-h2 elementor-widget elementor-widget-heading\" data-id=\"15bf6aeb\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Utiliser correctement les donn\u00e9es v\u00e9rifi\u00e9es de 261,24 kWh<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-58661802 auto-p elementor-widget elementor-widget-heading\" data-id=\"58661802\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default translation-block\">La documentation technique fournie par MegSolid r\u00e9pertorie le <strong><a href=\"https:\/\/www.solidess.com\/fr\/product\/stockage-denergie-solide-liquide-megasolide\/\" target=\"_blank\" style=\"color:#61CE70\">syst\u00e8me de stockage d\u2019\u00e9nergie hybride \u00e0 l\u2019\u00e9tat solide de 261,24 kWh<\/a><\/strong>, dont <strong>l\u2019\u00e9nergie nominale est de 261,24 kWh<\/strong> et <strong>la puissance apparente nominale est de 125 kVA c\u00f4t\u00e9 courant alternatif<\/strong>. La configuration de batterie indiqu\u00e9e est 1P260S avec des cellules LFP hybrides \u00e0 l\u2019\u00e9tat solide de 314 Ah. La source indique une tension nominale de 832 Vcc, une plage de tension de 676 \u00e0 936 Vcc et une tension c\u00f4t\u00e9 courant alternatif de 480 V ou 400 V \u00b115 % \u00e0 50\/60 Hz.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-94b9c8b3 auto-p elementor-widget elementor-widget-heading\" data-id=\"94b9c8b3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Cette m\u00eame source mentionne un rendement maximal du syst\u00e8me de 90%, un indice de protection IP54, un syst\u00e8me de refroidissement par liquide intelligent et la possibilit\u00e9 de faire fonctionner jusqu\u2019\u00e0 10 unit\u00e9s en parall\u00e8le. Elle d\u00e9crit \u00e9galement un syst\u00e8me d\u2019alerte pr\u00e9coce bas\u00e9 sur l\u2019IA, un syst\u00e8me de d\u00e9tection multicapteurs, ainsi que des dispositifs d\u2019extinction d\u2019incendie \u00e0 base de Novec et d\u2019eau. Il s'agit l\u00e0 de d\u00e9clarations relatives au produit provenant de la source cit\u00e9e ; elles ne sauraient se substituer \u00e0 une \u00e9valuation des risques sp\u00e9cifique au site, \u00e0 une strat\u00e9gie de lutte contre l'incendie, \u00e0 une conception des ouvrages de g\u00e9nie civil, \u00e0 une conception d'installation ou \u00e0 la v\u00e9rification des exigences locales.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-71b81f09 auto-p elementor-widget elementor-widget-heading\" data-id=\"71b81f09\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">L\u2019aptitude au fonctionnement en parall\u00e8le ne vaut pas approbation automatique d\u2019une implantation donn\u00e9e dans l\u2019imprimerie. L\u2019\u00e9quipe du projet doit encore confirmer l\u2019architecture du r\u00e9seau collecteur c\u00f4t\u00e9 courant alternatif, les communications, la coordination des protections, le niveau de courant de d\u00e9faut, la m\u00e9thode d\u2019isolement, les proc\u00e9dures d\u2019urgence et les essais de r\u00e9ception. La configuration r\u00e9elle du projet doit rester soumise \u00e0 un examen technique et \u00e0 la confirmation du fabricant.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c7bd6d62 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"c7bd6d62\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Pr\u00e9ciser ce que d\u00e9signe un \u00ab ensemble complet \u00bb dans la demande de devis<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-285bd13a auto-p elementor-widget elementor-widget-heading\" data-id=\"285bd13a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Une demande d\u2019ensemble complet devrait donner lieu \u00e0 un descriptif \u00e9crit du p\u00e9rim\u00e8tre. Dans le domaine de la <em>fabrication de BESS<\/em>, l\u2019ensemble d\u2019\u00e9quipements fourni par le fabricant n\u2019inclut pas n\u00e9cessairement le fret, les formalit\u00e9s douani\u00e8res, le g\u00e9nie civil, l\u2019installation, le raccordement au r\u00e9seau, les permis locaux, la mise en service ou l\u2019assistance \u00e0 l\u2019exploitation \u00e0 long terme. Chaque soumissionnaire devrait pr\u00e9ciser les \u00e9l\u00e9ments inclus, les exclusions, les options et les responsabilit\u00e9s attribu\u00e9es \u00e0 l\u2019entreprise EPC locale.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d8b5c03f auto-p elementor-widget elementor-widget-heading\" data-id=\"d8b5c03f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Au minimum, demandez une nomenclature d\u00e9taill\u00e9e indiquant les syst\u00e8mes de batteries, les PCS, les \u00e9quipements de commande et de gestion thermique, les \u00e9quipements d\u2019extinction d\u2019incendie le cas \u00e9ch\u00e9ant, les armoires ou conteneurs, les transformateurs le cas \u00e9ch\u00e9ant et les accessoires pr\u00e9vus. Demandez aussi des plans d\u2019implantation pr\u00e9liminaires, un sch\u00e9ma unifilaire, des fiches techniques propres \u00e0 chaque mod\u00e8le, une description de l\u2019interface de communication, le p\u00e9rim\u00e8tre du conditionnement pour l\u2019exp\u00e9dition et un registre des exclusions.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c132069c auto-p elementor-widget elementor-widget-heading\" data-id=\"c132069c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Pour les projets qui n\u00e9cessitent des \u00e9quipements de conversion autonomes, MegSolid r\u00e9pertorie une plateforme <strong><a href=\"https:\/\/www.solidess.com\/fr\/product\/systeme-de-conversion-denergie-megsolid\/\" target=\"_blank\" style=\"color:#61CE70\">PCS avec transformateur d\u2019isolement<\/a><\/strong> destin\u00e9e au couplage c\u00f4t\u00e9 courant alternatif en modes raccord\u00e9 au r\u00e9seau et hors r\u00e9seau, avec basculement automatique entre les deux modes. La documentation fournie par MegSolid r\u00e9pertorie des mod\u00e8les d\u2019une puissance nominale de sortie de 30 kW \u00e0 500 kW, avec des plages de tension c\u00f4t\u00e9 courant continu et des rendements propres \u00e0 chaque mod\u00e8le. V\u00e9rifiez, avant de choisir le mod\u00e8le, que la plage de tension de la batterie retenue est compatible avec la plage de tension c\u00f4t\u00e9 courant continu du PCS dans les conditions de fonctionnement d\u00e9finies pour le projet.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c713ddfa auto-h2 elementor-widget elementor-widget-heading\" data-id=\"c713ddfa\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Faire de la preuve technique une condition pr\u00e9alable \u00e0 toute comparaison commerciale<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a7ce4545 auto-p elementor-widget elementor-widget-heading\" data-id=\"a7ce4545\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Un prix inf\u00e9rieur ne suffit pas \u00e0 comparer des offres dont les mod\u00e8les, les limites \u00e9lectriques, les essais, les preuves de conformit\u00e9 et les p\u00e9rim\u00e8tres de livraison diff\u00e8rent. Le dossier de demande de devis devrait exiger une r\u00e9ponse tra\u00e7able. Pour chaque valeur technique d\u00e9clar\u00e9e, le soumissionnaire devrait pr\u00e9ciser le mod\u00e8le, la version du document, les conditions d\u2019essai le cas \u00e9ch\u00e9ant et si l\u2019\u00e9l\u00e9ment est compris dans le prix propos\u00e9.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b101b7ef elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"b101b7ef\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>Tra\u00e7abilit\u00e9 pr\u00e9cise des mod\u00e8les :<\/strong> identifier les mod\u00e8les de batterie, de PCS, de BMS, d'EMS, de bo\u00eetier et de syst\u00e8me de protection contre les incendies.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>Analyse de la compatibilit\u00e9 \u00e9lectrique :<\/strong> Documentez les limites de tension de la batterie, la plage de tension c\u00f4t\u00e9 courant continu du PCS, la tension c\u00f4t\u00e9 courant alternatif, la fr\u00e9quence, la configuration du transformateur et les interfaces de protection.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>V\u00e9rification du certificat :<\/strong> demander les certificats r\u00e9els correspondant pr\u00e9cis\u00e9ment au mod\u00e8le, \u00e0 la norme, \u00e0 l'organisme \u00e9metteur, au num\u00e9ro de rapport, \u00e0 la dur\u00e9e de validit\u00e9 et au march\u00e9 vis\u00e9.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>Essais de r\u00e9ception en usine :<\/strong> convenir de la proc\u00e9dure FAT, des crit\u00e8res d'acceptation, du processus de pr\u00e9sence de t\u00e9moins, de la documentation et de la gestion des exceptions avant la mise en production.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>Essais de r\u00e9ception sur site :<\/strong> D\u00e9finissez le p\u00e9rim\u00e8tre des essais SAT pour les interfaces, les modes de fonctionnement, les alarmes, les commandes et les documents de remise de l\u2019installation.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>P\u00e9rim\u00e8tre commercial :<\/strong> conditions de garantie, pi\u00e8ces de rechange, formation, assistance \u00e0 la mise en service, conditions d'exp\u00e9dition et exclusions.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f7e3d663 auto-p elementor-widget elementor-widget-heading\" data-id=\"f7e3d663\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default translation-block\">Le <strong><a href=\"https:\/\/www.solidess.com\/fr\/ressource\/\" target=\"_blank\" style=\"color:#61CE70\">Centre de ressources MegSolid<\/a><\/strong> et <strong><a href=\"https:\/\/www.solidess.com\/fr\/bess\/actualites\/\" target=\"_blank\" style=\"color:#61CE70\">les actualit\u00e9s et analyses sur les BESS<\/a><\/strong> peuvent aider l\u2019acheteur \u00e0 entamer ses recherches sur les produits et les applications. Le choix d\u2019achat final devrait toutefois reposer sur la documentation \u00e0 jour du mod\u00e8le fournie avec le devis. Une page de cat\u00e9gorie, une brochure g\u00e9n\u00e9rale ou une pr\u00e9sentation de gamme ne devrait pas servir de preuve qu\u2019un projet donn\u00e9 respecte une norme requise.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-425aee80 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"425aee80\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Attribuer explicitement les responsabilit\u00e9s en mati\u00e8re de livraison au Nigeria et d'EPC<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2c038994 auto-p elementor-widget elementor-widget-heading\" data-id=\"2c038994\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">La documentation fournie par MegSolid n\u2019atteste au Nigeria ni l\u2019existence d\u2019un bureau ou d\u2019un entrep\u00f4t, ni la r\u00e9alisation d\u2019un projet install\u00e9, ni l\u2019approbation du raccordement au r\u00e9seau d\u2019un mod\u00e8le pr\u00e9cis. Elle n\u2019indique pas non plus les stocks actuels, le prix du projet, le d\u00e9lai ni un engagement de livraison pour cette demande. <strong>Informations non disponibles dans les fichiers source actuels de MegSolid :<\/strong> un engagement de livraison au Nigeria propre au projet. Ces \u00e9l\u00e9ments devraient \u00eatre confirm\u00e9s directement pendant les \u00e9changes commerciaux et ne pas \u00eatre d\u00e9duits d\u2019une pr\u00e9sentation g\u00e9n\u00e9rale de l\u2019entreprise.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0c65ec75 auto-p elementor-widget elementor-widget-heading\" data-id=\"0c65ec75\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Une entreprise EPC locale comp\u00e9tente devrait examiner les conditions du site, les permis, les travaux de g\u00e9nie civil et d\u2019\u00e9lectricit\u00e9, la mise \u00e0 la terre, la coordination des protections, le raccordement, l\u2019installation, la mise en service et les approbations locales applicables. Cet examen est n\u00e9cessaire m\u00eame si le fabricant fournit un ensemble d\u2019\u00e9quipements techniquement d\u00e9taill\u00e9. Les interfaces entre le p\u00e9rim\u00e8tre des \u00e9quipements fournis et celui des travaux sur site de l\u2019entreprise EPC devraient \u00eatre clairement d\u00e9finies.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6345f748 auto-p elementor-widget elementor-widget-heading\" data-id=\"6345f748\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default translation-block\">MegSolid cite parmi ses domaines prioritaires les syst\u00e8mes commerciaux et industriels (C&amp;I), les syst\u00e8mes conteneuris\u00e9s, le solaire avec stockage et l\u2019int\u00e9gration des micror\u00e9seaux, ainsi que les entreprises EPC et les distributeurs B2B. Pour d\u00e9couvrir la gamme, les acheteurs peuvent consulter le <strong><a href=\"https:\/\/www.solidess.com\/fr\/bess\/\" target=\"_blank\" style=\"color:#61CE70\">portail des syst\u00e8mes de stockage d\u2019\u00e9nergie par batterie<\/a><\/strong>, la <strong><a href=\"https:\/\/www.solidess.com\/fr\/stockage-denergie-par-conteneur\/\" target=\"_blank\" style=\"color:#61CE70\">cat\u00e9gorie des syst\u00e8mes de stockage d\u2019\u00e9nergie en conteneur<\/a><\/strong> et la <strong><a href=\"https:\/\/www.solidess.com\/fr\/systemes-de-stockage-denergie-a-letat-solide\/\" target=\"_blank\" style=\"color:#61CE70\">page consacr\u00e9e aux syst\u00e8mes de stockage d\u2019\u00e9nergie \u00e0 l\u2019\u00e9tat solide<\/a><\/strong>. Ces ressources devraient \u00e9clairer la pr\u00e9paration du dossier technique propre au projet sans s\u2019y substituer.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a8631509 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"a8631509\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Transformer la demande pr\u00e9liminaire en une comparaison des fournisseurs pouvant faire l'objet d'un audit<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-083044a4 auto-p elementor-widget elementor-widget-heading\" data-id=\"083044a4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">La prochaine \u00e9tape consiste \u00e0 remplir le questionnaire en six parties et \u00e0 envoyer une demande de devis identique \u00e0 chacun des <em>fabricants de BESS pr\u00e9s\u00e9lectionn\u00e9s<\/em>. Indiquez l\u2019emplacement exact du site, la puissance de pointe, les donn\u00e9es de charge par intervalle si elles sont disponibles, le programme de fonctionnement des charges critiques, la dur\u00e9e demand\u00e9e ou l\u2019objectif d\u2019\u00e9nergie utilisable c\u00f4t\u00e9 courant alternatif, les caract\u00e9ristiques des installations photovolta\u00efques et du groupe \u00e9lectrog\u00e8ne, le mode de fonctionnement pr\u00e9vu, l\u2019environnement d\u2019installation, l\u2019altitude, l\u2019emprise au sol, les normes requises et la date de livraison souhait\u00e9e.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-03de608e auto-p elementor-widget elementor-widget-heading\" data-id=\"03de608e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Demandez \u00e0 chaque soumissionnaire de fournir la m\u00eame structure de r\u00e9ponse : configuration pr\u00e9liminaire, liste pr\u00e9cise des mod\u00e8les, fiches techniques, nomenclature, sch\u00e9ma unifilaire, plan d\u2019implantation, \u00e9l\u00e9ments inclus et exclus, \u00e9tat des certificats, proposition relative aux tests FAT et SAT, documentation relative \u00e0 la garantie, conditions commerciales et registre des points en suspens. Cela permet d\u2019\u00e9tablir une comparaison que l\u2019imprimerie, l\u2019EPC, le distributeur et le d\u00e9cideur financier peuvent examiner sur une base commune.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2d72249f auto-p elementor-widget elementor-widget-heading\" data-id=\"2d72249f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Pour obtenir des \u00e9l\u00e9ments compl\u00e9mentaires en vue de la pr\u00e9paration du projet, consultez le <strong><a href=\"https:\/\/www.solidess.com\/fr\/guide-sur-le-stockage-denergie-a-letat-solide-ci-2026\/\" target=\"_blank\" style=\"color:#61CE70\">Guide C&amp;I sur le stockage d'\u00e9nergie \u00e0 l'\u00e9tat solide<\/a><\/strong> et le <strong><a href=\"https:\/\/www.solidess.com\/fr\/bess\/cas-dapplication\/\" target=\"_blank\" style=\"color:#61CE70\">recueil de cas d\u2019application des BESS<\/a><\/strong>. Une fois les donn\u00e9es techniques pr\u00eates \u00e0 \u00eatre transmises, ouvrez la discussion commerciale par la <strong><a href=\"https:\/\/www.solidess.com\/fr\/contacter-megsolid\/\" target=\"_blank\" style=\"color:#61CE70\">page de contact de MegSolid<\/a><\/strong>. Toute offre d\u00e9finitive devrait rester subordonn\u00e9e \u00e0 la confirmation des informations encore manquantes sur la charge, le site, la conformit\u00e9 et la livraison.<\/p>\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-288c0c17 auto-faq e-flex e-con-boxed e-con e-child\" data-id=\"288c0c17\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-4940173f elementor-tablet-align-center elementor-align-center auto-cta elementor-widget elementor-widget-button\" data-id=\"4940173f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"#elementor-action%3Aaction%3Dpopup%3Aopen%26settings%3DeyJpZCI6Ijk0OCIsInRvZ2dsZSI6ZmFsc2V9\" target=\"_blank\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Demander un devis BESS au fabricant MegSolid<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-958e597b elementor-widget elementor-widget-heading\" data-id=\"958e597b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">FAQ<\/h2>\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-50286f67 e-con-full e-flex e-con e-child\" data-id=\"50286f67\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-795a8a4b elementor-widget elementor-widget-n-accordion\" data-id=\"795a8a4b\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;default_state&quot;:&quot;all_collapsed&quot;,&quot;max_items_expended&quot;:&quot;one&quot;,&quot;n_accordion_animation_duration&quot;:{&quot;unit&quot;:&quot;ms&quot;,&quot;size&quot;:400,&quot;sizes&quot;:[]}}\" data-widget_type=\"nested-accordion.default\">\n\t\t\t\t\t\t\t<div class=\"e-n-accordion\" aria-label=\"Accord\u00e9on. Ouvrez les liens \u00e0 l&#039;aide de la touche Entr\u00e9e ou de la barre d&#039;espace, fermez-les avec la touche \u00c9chap et naviguez \u00e0 l&#039;aide des touches fl\u00e9ch\u00e9es.\">\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2030\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"1\" tabindex=\"0\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2030\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Une demande de 1 000 kWh est-elle suffisante pour opter pour un syst\u00e8me de stockage d'\u00e9nergie par batterie (BESS) industriel ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2030\" class=\"elementor-element elementor-element-16d31fb0 e-con-full e-flex e-con e-child\" data-id=\"16d31fb0\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2030\" class=\"elementor-element elementor-element-03dadbfe e-con-full e-flex e-con e-child\" data-id=\"03dadbfe\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-eb3e0892 elementor-widget elementor-widget-heading\" data-id=\"eb3e0892\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Non. Il s'agit d'un objectif \u00e9nerg\u00e9tique initial. Le dossier technique doit \u00e9galement inclure la puissance CA requise, la dur\u00e9e de l'alimentation de secours, le profil de charge, la priorit\u00e9 des charges critiques, le mode de fonctionnement, les d\u00e9tails relatifs aux installations photovolta\u00efques et aux g\u00e9n\u00e9rateurs, les conditions du site ainsi que les normes applicables.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2031\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"2\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2031\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Pourquoi faut-il d\u00e9terminer la puissance en courant alternatif avant de fixer la capacit\u00e9 de la batterie ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2031\" class=\"elementor-element elementor-element-1fc31cab e-con-full e-flex e-con e-child\" data-id=\"1fc31cab\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2031\" class=\"elementor-element elementor-element-e7907348 e-con-full e-flex e-con e-child\" data-id=\"e7907348\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-e89c9191 elementor-widget elementor-widget-heading\" data-id=\"e89c9191\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">La puissance c\u00f4t\u00e9 courant alternatif d\u00e9termine le PCS et l\u2019interface \u00e9lectrique n\u00e9cessaires pour alimenter la charge d\u00e9finie. L\u2019\u00e9nergie de la batterie aide \u00e0 d\u00e9terminer combien de temps cette charge peut \u00eatre aliment\u00e9e.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2032\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"3\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2032\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> L\u2019\u00e9nergie nominale de la batterie peut-elle \u00eatre pr\u00e9sent\u00e9e comme l\u2019\u00e9nergie utilisable c\u00f4t\u00e9 courant alternatif \u00e0 l\u2019usine ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2032\" class=\"elementor-element elementor-element-68ff7f4c e-con-full e-flex e-con e-child\" data-id=\"68ff7f4c\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2032\" class=\"elementor-element elementor-element-89e398b2 e-con-full e-flex e-con e-child\" data-id=\"89e398b2\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-711cb18e elementor-widget elementor-widget-heading\" data-id=\"711cb18e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Non. L\u2019\u00e9nergie nominale de la batterie et l\u2019\u00e9nergie utilisable c\u00f4t\u00e9 courant alternatif sont des grandeurs diff\u00e9rentes. La valeur d\u2019\u00e9nergie utilisable c\u00f4t\u00e9 courant alternatif propre au projet doit \u00eatre confirm\u00e9e pour la configuration retenue et les conditions de fonctionnement d\u00e9finies.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2033\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"4\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2033\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Quelles sont les valeurs ESSA0100B-0215 r\u00e9pertori\u00e9es dans la documentation technique de MegSolid ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2033\" class=\"elementor-element elementor-element-3b91f24d e-con-full e-flex e-con e-child\" data-id=\"3b91f24d\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2033\" class=\"elementor-element elementor-element-146290e5 e-con-full e-flex e-con e-child\" data-id=\"146290e5\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-dffec54c elementor-widget elementor-widget-heading\" data-id=\"dffec54c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">La documentation technique de MegSolid de juin 2026 d\u00e9crit le mod\u00e8le ESSA0100B-0215 comme ayant une capacit\u00e9 nominale de 215,04 kWh, une puissance nominale en courant alternatif de 100 kW, une plage de tension de batterie comprise entre 672 et 850 V, une composition chimique LFP et un refroidissement par air.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2034\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"5\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2034\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Quelles sont les caract\u00e9ristiques techniques du syst\u00e8me de stockage d'\u00e9nergie hybride \u00e0 l'\u00e9tat solide de 261,24 kWh de MegSolid ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2034\" class=\"elementor-element elementor-element-b7be7e40 e-con-full e-flex e-con e-child\" data-id=\"b7be7e40\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2034\" class=\"elementor-element elementor-element-e4b2e469 e-con-full e-flex e-con e-child\" data-id=\"e4b2e469\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-1173fc2e elementor-widget elementor-widget-heading\" data-id=\"1173fc2e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">La source fournie indique une \u00e9nergie nominale de 261,24 kWh, une puissance apparente nominale de 125 kVA c\u00f4t\u00e9 courant alternatif, des cellules LFP hybrides \u00e0 l\u2019\u00e9tat solide de 314 Ah, une tension nominale de 832 Vcc, une plage de tension de 676 \u00e0 936 Vcc et un rendement maximal du syst\u00e8me de 90 %.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2035\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"6\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2035\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Peut-on d\u00e9terminer le nombre d\u2019unit\u00e9s du syst\u00e8me en divisant 1 000 kWh par la capacit\u00e9 nominale d\u2019une unit\u00e9 ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2035\" class=\"elementor-element elementor-element-b55ad5d0 e-con-full e-flex e-con e-child\" data-id=\"b55ad5d0\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2035\" class=\"elementor-element elementor-element-0605b475 e-con-full e-flex e-con e-child\" data-id=\"0605b475\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-d7cd9223 elementor-widget elementor-widget-heading\" data-id=\"d7cd9223\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Non. Ce calcul ne permet pas de d\u00e9terminer la puissance en courant alternatif, l'\u00e9nergie utilisable, la demande auxiliaire, la redondance, les syst\u00e8mes de commande, les dispositifs de protection, l'implantation ni l'ad\u00e9quation du site. Un syst\u00e8me \u00e0 plusieurs unit\u00e9s n\u00e9cessite une \u00e9tude technique du projet.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2036\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"7\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2036\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Quels documents doivent figurer dans un devis complet de BESS ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2036\" class=\"elementor-element elementor-element-cd99494e e-con-full e-flex e-con e-child\" data-id=\"cd99494e\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2036\" class=\"elementor-element elementor-element-48b1fe1b e-con-full e-flex e-con e-child\" data-id=\"48b1fe1b\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-e8016591 elementor-widget elementor-widget-heading\" data-id=\"e8016591\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Demandez les r\u00e9f\u00e9rences exactes des mod\u00e8les, une nomenclature d\u00e9taill\u00e9e, les fiches techniques, un sch\u00e9ma unifilaire pr\u00e9liminaire, les plans d'implantation, la liste des \u00e9l\u00e9ments inclus et exclus, l'\u00e9tat des certificats, les plans relatifs aux essais FAT et SAT, les conditions de garantie et les conditions commerciales.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2037\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"8\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2037\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Comment un acheteur doit-il \u00e9valuer les d\u00e9clarations de s\u00e9curit\u00e9 relatives aux syst\u00e8mes de stockage d'\u00e9nergie par batterie (BESS) ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2037\" class=\"elementor-element elementor-element-4285a288 e-con-full e-flex e-con e-child\" data-id=\"4285a288\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2037\" class=\"elementor-element elementor-element-7b23994f e-con-full e-flex e-con e-child\" data-id=\"7b23994f\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ccb8a6f1 elementor-widget elementor-widget-heading\" data-id=\"ccb8a6f1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Demandez la documentation relative au mod\u00e8le pr\u00e9cis, les conditions d'essai le cas \u00e9ch\u00e9ant, la strat\u00e9gie anti-incendie propos\u00e9e, les hypoth\u00e8ses d'installation et les justificatifs d'homologation applicables. Les formulations g\u00e9n\u00e9rales en mati\u00e8re de s\u00e9curit\u00e9 ne constituent pas des preuves sp\u00e9cifiques au projet.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2038\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"9\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2038\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Pourquoi les donn\u00e9es relatives aux installations photovolta\u00efques et aux groupes \u00e9lectrog\u00e8nes diesel sont-elles n\u00e9cessaires pour le dimensionnement d'un syst\u00e8me de stockage d'\u00e9nergie par batterie (BESS) ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2038\" class=\"elementor-element elementor-element-86039090 e-con-full e-flex e-con e-child\" data-id=\"86039090\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2038\" class=\"elementor-element elementor-element-c30e356c e-con-full e-flex e-con e-child\" data-id=\"c30e356c\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-f4eccc40 elementor-widget elementor-widget-heading\" data-id=\"f4eccc40\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Ils ont une incidence sur la philosophie d'exploitation pr\u00e9vue, la configuration des couplages, les commandes, les interfaces de protection et la r\u00e9partition des responsabilit\u00e9s entre le fournisseur du syst\u00e8me de stockage d'\u00e9nergie par batterie (BESS) et le ma\u00eetre d'\u0153uvre (EPC).<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2039\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"10\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2039\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Quelles informations l'imprimerie doit-elle fournir avant de demander un devis d\u00e9finitif ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2039\" class=\"elementor-element elementor-element-ebc13751 e-con-full e-flex e-con e-child\" data-id=\"ebc13751\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2039\" class=\"elementor-element elementor-element-160b952b e-con-full e-flex e-con e-child\" data-id=\"160b952b\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-b95d9803 elementor-widget elementor-widget-heading\" data-id=\"b95d9803\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Indiquez l\u2019emplacement du site, la puissance de pointe, les donn\u00e9es de charge si elles sont disponibles, le programme de fonctionnement des charges critiques, la dur\u00e9e requise, les heures de fonctionnement, les caract\u00e9ristiques de l\u2019installation photovolta\u00efque et du groupe \u00e9lectrog\u00e8ne, le mode de fonctionnement, les conditions d\u2019installation, les normes requises et la date de livraison demand\u00e9e.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-20310\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"11\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-20310\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> La documentation fournie par MegSolid confirme-t-elle l\u2019existence d\u2019un bureau, d\u2019un entrep\u00f4t ou d\u2019un projet de BESS install\u00e9 au Nigeria ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-20310\" class=\"elementor-element elementor-element-66f44973 e-con-full e-flex e-con e-child\" data-id=\"66f44973\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-20310\" class=\"elementor-element elementor-element-12a70a16 e-con-full e-flex e-con e-child\" data-id=\"12a70a16\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-7e2f69b8 elementor-widget elementor-widget-heading\" data-id=\"7e2f69b8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Non. Les documents MegSolid actuellement disponibles ne font \u00e9tat d\u2019aucun bureau, entrep\u00f4t ni projet de BESS install\u00e9 au Nigeria.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-20311\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"12\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-20311\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> La documentation fournie prouve-t-elle qu\u2019un mod\u00e8le MegSolid pr\u00e9cis est approuv\u00e9 au regard du code de raccordement au r\u00e9seau nig\u00e9rian ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-20311\" class=\"elementor-element elementor-element-b3041f78 e-con-full e-flex e-con e-child\" data-id=\"b3041f78\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-20311\" class=\"elementor-element elementor-element-9f19331b e-con-full e-flex e-con e-child\" data-id=\"9f19331b\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-9447734f elementor-widget elementor-widget-heading\" data-id=\"9447734f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Non. La documentation fournie par MegSolid n\u2019\u00e9tablit pas qu\u2019un mod\u00e8le pr\u00e9cis a \u00e9t\u00e9 approuv\u00e9 au regard du code de raccordement au r\u00e9seau nig\u00e9rian. Une entreprise EPC locale comp\u00e9tente devrait confirmer les exigences applicables et les responsabilit\u00e9s en mati\u00e8re d\u2019approbation.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-20312\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"13\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-20312\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Qui devrait v\u00e9rifier les exigences locales en mati\u00e8re d'installation et de conformit\u00e9 pour un syst\u00e8me de stockage d'\u00e9nergie par batterie (BESS) destin\u00e9 \u00e0 une imprimerie nig\u00e9riane ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-20312\" class=\"elementor-element elementor-element-2e19017f e-con-full e-flex e-con e-child\" data-id=\"2e19017f\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-20312\" class=\"elementor-element elementor-element-5f79a132 e-con-full e-flex e-con e-child\" data-id=\"5f79a132\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-cc2f59e2 elementor-widget elementor-widget-heading\" data-id=\"cc2f59e2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">L\u2019acheteur devrait faire appel \u00e0 une entreprise EPC locale comp\u00e9tente pour examiner les conditions du site, les permis, les travaux de g\u00e9nie civil et d\u2019\u00e9lectricit\u00e9, le raccordement, la coordination des protections, l\u2019installation, la mise en service et les approbations locales applicables.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Une demande de 1 000 kWh pour une imprimerie nig\u00e9riane constitue un bon point de d\u00e9part, mais elle ne pr\u00e9cise pas encore la puissance CA requise, la dur\u00e9e de fonctionnement, les interfaces sur site ni l'\u00e9tendue des travaux d'installation. Ce guide explique comment pr\u00e9parer un appel d'offres fond\u00e9 sur des donn\u00e9es concr\u00e8tes \u00e0 l'intention de MegSolid ou d'un autre fabricant de syst\u00e8mes de stockage d'\u00e9nergie par batterie (BESS), sans faire de suppositions sur les donn\u00e9es manquantes du projet.<\/p>","protected":false},"author":4,"featured_media":4444,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"_joinchat":[],"footnotes":""},"categories":[1,713],"tags":[154,148,99,240,241],"class_list":["post-4537","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-bess","category-bess-procurement-economics","tag-bess-procurement","tag-bess-rfq","tag-industrial-energy-storage","tag-nigeria-energy-storage","tag-printing-factory-backup"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/posts\/4537","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/comments?post=4537"}],"version-history":[{"count":7,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/posts\/4537\/revisions"}],"predecessor-version":[{"id":4587,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/posts\/4537\/revisions\/4587"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/media\/4444"}],"wp:attachment":[{"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/media?parent=4537"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/categories?post=4537"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/tags?post=4537"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}