{"id":4729,"date":"2026-08-12T09:24:46","date_gmt":"2026-08-12T01:24:46","guid":{"rendered":"https:\/\/www.solidess.com\/?p=4729"},"modified":"2026-10-08T18:29:22","modified_gmt":"2026-10-08T10:29:22","slug":"comment-choisir-entre-un-stockage-par-batterie-commercial-bess-de-215-kwh-et-de-261-kwh","status":"publish","type":"post","link":"https:\/\/www.solidess.com\/fr\/how-to-choose-commercial-battery-storage-215kwh-vs-261kwh-bess\/","title":{"rendered":"Comment choisir le stockage sur batterie pour le secteur commercial : BESS de 215 kWh par rapport \u00e0 261 kWh"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"4729\" class=\"elementor elementor-4729\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-bf4793c e-con-full auto-article-root e-flex e-con e-parent\" data-id=\"bf4793c\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-eef148ad auto-p elementor-widget elementor-widget-heading\" data-id=\"eef148ad\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Le choix des syst\u00e8mes commerciaux de stockage d'\u00e9nergie MegSolid ne doit pas se fonder uniquement sur la capacit\u00e9 des batteries. A <strong><a href=\"https:\/\/www.solidess.com\/fr\/product\/systeme-de-stockage-denergie-en-armoire-exterieure\/\" target=\"_blank\" style=\"color:#61CE70\">215,04 kWh<\/a><\/strong>\n armoire et un <strong><a href=\"https:\/\/www.solidess.com\/fr\/product\/stockage-denergie-solide-liquide-megasolide\/\" target=\"_blank\" style=\"color:#61CE70\">261,24 kWh<\/a><\/strong>\n Les devis propos\u00e9s par les fabricants de armoires peuvent sembler similaires \u00e0 premi\u00e8re vue, mais ils peuvent d\u00e9boucher sur des r\u00e9sultats tr\u00e8s diff\u00e9rents une fois pris en compte les besoins du site en courant alternatif, le facteur de puissance, la plage de d\u00e9charge, les conditions ambiantes et les projets d'extension futurs.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c770bcee auto-image elementor-widget elementor-widget-image\" data-id=\"c770bcee\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"1448\" height=\"1086\" src=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/Commercial-Battery-Storage-RFQ-Load-Profile-Review.png\" class=\"attachment-1536x1536 size-1536x1536 wp-image-4740\" alt=\"| MegSolid Hybrid Solid-State Energy Storage\" srcset=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/Commercial-Battery-Storage-RFQ-Load-Profile-Review.png 1448w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/Commercial-Battery-Storage-RFQ-Load-Profile-Review-300x225.png 300w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/Commercial-Battery-Storage-RFQ-Load-Profile-Review-1024x768.png 1024w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/Commercial-Battery-Storage-RFQ-Load-Profile-Review-768x576.png 768w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/Commercial-Battery-Storage-RFQ-Load-Profile-Review-600x450.png 600w\" sizes=\"(max-width: 1448px) 100vw, 1448px\">\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8bab8ce7 auto-p elementor-widget elementor-widget-heading\" data-id=\"8bab8ce7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Pour un EPC, le risque r\u00e9side dans la conception d\u2019un syst\u00e8me incapable de fournir la puissance alternative requise au point de fonctionnement. Pour un gestionnaire d\u2019installations, le risque est de payer pour davantage d\u2019\u00e9nergie stock\u00e9e tout en ne parvenant pas \u00e0 prot\u00e9ger les charges essentielles lors d\u2019un pic de demande ou d\u2019une coupure de courant. Pour un distributeur, le risque est de proposer un armoire alors que le profil de charge du client indique d\u00e9j\u00e0 la n\u00e9cessit\u00e9 d\u2019un syst\u00e8me sur mesure ou conteneuris\u00e9 plus grand.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-35f44a0c auto-p elementor-widget elementor-widget-heading\" data-id=\"35f44a0c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">La question concr\u00e8te n'est pas \u201c Quelle batterie offre le plus de kWh ? \u201d, mais : <strong>Quelle configuration de syst\u00e8me de stockage par batterie \u00e0 usage commercial permet de r\u00e9pondre aux besoins en kW ou en kVA de ce site pendant la dur\u00e9e requise, dans ses conditions d'exploitation r\u00e9elles ?<\/strong><\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8885b02e auto-p elementor-widget elementor-widget-heading\" data-id=\"8885b02e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">MegSolid propose deux solutions distinctes \u00e0 l'\u00e9chelle d'armoire pour cette comparaison. Aucun de ces deux syst\u00e8mes ne doit \u00eatre consid\u00e9r\u00e9 comme un produit hybride \u00e0 semi-conducteurs par d\u00e9faut. La composition chimique et la configuration fournies doivent \u00eatre confirm\u00e9es dans le devis sign\u00e9, la fiche technique et la nomenclature du projet concern\u00e9.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a3d8104e auto-table elementor-widget elementor-widget-text-editor\" data-id=\"a3d8104e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"cea-table-wrap\"><table><thead><tr><th>Point de d\u00e9cision<\/th><th>ESSA0100B-0215<\/th><th>MegSolid Energon 261 kWh<\/th><\/tr><\/thead><tbody><tr><td>Puissance nominale en courant alternatif<\/td><td>100 kW<\/td><td>125 kVA<\/td><\/tr><tr><td>Puissance nominale<\/td><td>215,04 kWh<\/td><td>261,24 kWh<\/td><\/tr><tr><td>Chimie des batteries<\/td><td>LFP<\/td><td>314Ah LFP<\/td><\/tr><tr><td>Gestion thermique<\/td><td>Refroidissement par air intelligent<\/td><td>Refroidissement par liquide<\/td><\/tr><tr><td>Question pertinente concernant l'achat<\/td><td>La charge requise peut-elle rester inf\u00e9rieure ou \u00e9gale \u00e0 100 kW ?<\/td><td>Quelle puissance en kW CA est n\u00e9cessaire compte tenu du facteur de puissance du projet ?<\/td><\/tr><\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6636123a auto-h2 elementor-widget elementor-widget-heading\" data-id=\"6636123a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Commencez par examiner le profil de charge, puis v\u00e9rifiez les caract\u00e9ristiques nominales indiqu\u00e9es sur la plaque signal\u00e9tique de la batterie<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-751fa0e5 auto-p elementor-widget elementor-widget-heading\" data-id=\"751fa0e5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Les syst\u00e8mes de stockage par batterie \u00e0 usage commercial sont acquis pour g\u00e9rer diff\u00e9rents \u00e9v\u00e9nements sur site : un pic de tarification en fonction de la demande, une d\u00e9charge programm\u00e9e en soir\u00e9e, une interruption du r\u00e9seau, une p\u00e9riode de soutien par g\u00e9n\u00e9rateur ou une fen\u00eatre de secours pour une charge critique. Chaque \u00e9v\u00e9nement pr\u00e9sente une courbe de puissance diff\u00e9rente.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-90a2effd auto-p elementor-widget elementor-widget-heading\" data-id=\"90a2effd\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Avant de comparer la capacit\u00e9 des armoires, recueillez des donn\u00e9es \u00e0 intervalles d'au moins 15 minutes et r\u00e9pondez aux cinq questions suivantes :<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-206dd366 elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"206dd366\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Quelle est la charge maximale que le BESS doit supporter ou compenser ?<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Cette valeur est-elle exprim\u00e9e en kW, en kVA ou en amp\u00e8res ?<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Combien de fois par jour cet \u00e9v\u00e9nement se produit-il ?<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Pendant combien de temps le syst\u00e8me doit-il maintenir le d\u00e9bit cible ?<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Quelles charges peuvent \u00eatre d\u00e9connect\u00e9es avant que la batterie ne doive les alimenter ?<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4bf7da2b auto-p elementor-widget elementor-widget-heading\" data-id=\"4bf7da2b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Un entrep\u00f4t peut conna\u00eetre un pic de consommation li\u00e9 \u00e0 la r\u00e9frig\u00e9ration et au compresseur, n\u00e9cessitant une puissance \u00e9lev\u00e9e pendant une p\u00e9riode limit\u00e9e. Une usine peut quant \u00e0 elle pr\u00e9senter une charge plus faible mais plus longue en soir\u00e9e, qui requiert davantage d'\u00e9nergie. Un site \u00e9quip\u00e9 de moteurs, de transformateurs ou pr\u00e9sentant un facteur de puissance faible doit \u00e9galement s'assurer que la capacit\u00e9 en courant alternatif est correctement \u00e9valu\u00e9e.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-bfde4d85 auto-p elementor-widget elementor-widget-heading\" data-id=\"bfde4d85\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">C'est pourquoi le raccourci suivant entra\u00eene des erreurs co\u00fbteuses : <strong>\u201c 261 kWh, c'est plus que 215 kWh, c'est donc automatiquement le choix le plus s\u00fbr. \u201d<\/strong> Ce n'est pas le cas. Une puissance nominale plus \u00e9lev\u00e9e ne permet pas de pallier un circuit d'alimentation CA sous-dimensionn\u00e9, un facteur de puissance ind\u00e9fini ou une charge d\u00e9passant la plage de fonctionnement pr\u00e9vue de l'armoire choisie.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-697645ea auto-h2 elementor-widget elementor-widget-heading\" data-id=\"697645ea\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Comprendre les notions de kW, kVA et kWh avant de comparer les armoires \u00e9lectriques<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f1863687 auto-p elementor-widget elementor-widget-heading\" data-id=\"f1863687\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\"><strong>kW<\/strong> c'est la puissance \u00e9lectrique r\u00e9elle requise par la charge. <strong>kVA<\/strong> C'est la puissance apparente. Sa relation avec le kW d\u00e9pend du facteur de puissance. <strong>kWh<\/strong> c'est de l'\u00e9nergie stock\u00e9e disponible au fil du temps.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2560f927 auto-p elementor-widget elementor-widget-heading\" data-id=\"2560f927\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">L'ESSA0100B-0215 a une puissance nominale de 100 kW CA et une capacit\u00e9 de 215,04 kWh. Le syst\u00e8me \u00e0 refroidissement liquide de 261,24 kWh a une puissance nominale de 125 kVA, et non pas automatiquement de 125 kW. Sa puissance r\u00e9elle disponible doit \u00eatre v\u00e9rifi\u00e9e en fonction du facteur de puissance du projet, du code de r\u00e9seau, du mode de fonctionnement et de la proposition technique sign\u00e9e.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8d04c833 auto-p elementor-widget elementor-widget-heading\" data-id=\"8d04c833\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Une \u00e9quipe charg\u00e9e des achats ne devrait donc jamais convertir 125 kVA en une valeur fixe de 125 kW simplement parce que ce chiffre est pratique pour une pr\u00e9sentation interne. Une telle hypoth\u00e8se peut cr\u00e9er un \u00e9cart entre les besoins du client en mati\u00e8re de charge critique et le syst\u00e8me livr\u00e9 sur site.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0a83a034 auto-table elementor-widget elementor-widget-text-editor\" data-id=\"0a83a034\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"cea-table-wrap\"><table><thead><tr><th>Saisie d'un appel d'offres<\/th><th>Pourquoi est-ce important ?<\/th><\/tr><\/thead><tbody><tr><td>Demande maximale du site en kW et en kVA<\/td><td>D\u00e9termine la puissance CA requise<\/td><\/tr><tr><td>Dur\u00e9e de d\u00e9charge requise<\/td><td>D\u00e9termine les besoins \u00e9nerg\u00e9tiques<\/td><\/tr><tr><td>Facteur de puissance au point de raccordement<\/td><td>\u00c9vite les hypoth\u00e8ses erron\u00e9es concernant la conversion entre kVA et kW<\/td><\/tr><tr><td>Liste des charges critiques<\/td><td>D\u00e9finit les \u00e9l\u00e9ments qui restent aliment\u00e9s en cas d'incident<\/td><\/tr><tr><td>Interface entre le r\u00e9seau, le g\u00e9n\u00e9rateur et l'installation photovolta\u00efque locale<\/td><td>D\u00e9termine les commandes et la s\u00e9quence de fonctionnement<\/td><\/tr><tr><td>Augmentation pr\u00e9vue de la charge \u00e0 l'avenir<\/td><td>\u00c9vite de se retrouver pr\u00e9matur\u00e9ment li\u00e9 \u00e0 un format d'armoire sp\u00e9cifique<\/td><\/tr><\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-cf5e7423 auto-p elementor-widget elementor-widget-heading\" data-id=\"cf5e7423\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Si l'objectif commercial est l'\u00e9cr\u00eatement des pics plut\u00f4t que l'alimentation de secours de l'ensemble de l'installation, le syst\u00e8me de stockage d'\u00e9nergie par batterie (BESS) doit uniquement couvrir la puissance mesur\u00e9e au-del\u00e0 de l'objectif fix\u00e9 pour le site. Le calcul de cette valeur doit reposer sur le profil de charge par intervalle, la structure tarifaire et le plan de r\u00e9partition. Pour cette logique commerciale, utilisez le <strong><a href=\"https:\/\/www.solidess.com\/fr\/maximiser-le-retour-sur-investissement-de-lecretage-des-pointes-pour-les-secteurs-commercial-et-industriel\/\" target=\"_blank\" style=\"color:#61ce70\">Guide technique sur les zones d'int\u00e9r\u00eat (ROI) pour l'\u00e9cr\u00eatement des pics C&amp;I<\/a><\/strong> \u00e0 titre de r\u00e9f\u00e9rence interne compl\u00e9mentaire.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-21b70336 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"21b70336\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Quand une armoire d'ext\u00e9rieur de 100 kW \/ 215,04 kWh est la solution la plus adapt\u00e9e<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a9082628 auto-p elementor-widget elementor-widget-heading\" data-id=\"a9082628\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">La solution ESSA0100B-0215 constitue une option viable lorsque le projet pr\u00e9sente des besoins en courant alternatif bien d\u00e9finis de l'ordre de 100 kW et que la dur\u00e9e requise peut \u00eatre respect\u00e9e une fois que les hypoth\u00e8ses relatives \u00e0 l'\u00e9nergie utilisable, aux charges auxiliaires et \u00e0 la r\u00e9serve d'exploitation ont \u00e9t\u00e9 convenues.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9bd0c2a2 auto-p elementor-widget elementor-widget-heading\" data-id=\"9bd0c2a2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Il ne s'agit pas simplement d'une version \u201c r\u00e9duite \u201d d'un syst\u00e8me commercial de stockage par batterie de plus grande envergure. Il s'agit d'une option distincte destin\u00e9e aux projets dont la charge critique ou les besoins en mati\u00e8re d'\u00e9cr\u00eatement des pics ne d\u00e9passent pas la limite de 100 kW CA.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-43d23996 auto-p elementor-widget elementor-widget-heading\" data-id=\"43d23996\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Il convient d'envisager cette approche dans les cas suivants :<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-27db4c1f elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"27db4c1f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">La puissance de d\u00e9charge requise de la batterie est inf\u00e9rieure ou \u00e9gale \u00e0 100 kW.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Le site peut mettre en place une strat\u00e9gie de d\u00e9lestage contr\u00f4l\u00e9 si la demande totale de l'installation est plus \u00e9lev\u00e9e.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">L'op\u00e9ration de d\u00e9chargement est limit\u00e9e et reproductible, contrairement \u00e0 une sauvegarde compl\u00e8te du site dont les exigences ne sont pas clairement d\u00e9finies.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Le projet n\u00e9cessite une armoire LFP d'ext\u00e9rieur \u00e9quip\u00e9e d'un syst\u00e8me de refroidissement par air intelligent.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Le client est pr\u00eat \u00e0 d\u00e9terminer la dur\u00e9e de fonctionnement en fonction du profil de charge r\u00e9el, plut\u00f4t que de partir du principe que la totalit\u00e9 des 215,04 kWh est disponible dans toutes les conditions de fonctionnement.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e006973b auto-p elementor-widget elementor-widget-heading\" data-id=\"e006973b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">La capacit\u00e9 nominale de 215,04 kWh de l'armoire doit \u00eatre consid\u00e9r\u00e9e comme un point de d\u00e9part pour la conception technique, et non comme une garantie d'autonomie. La r\u00e9serve de batterie, les limites de fonctionnement li\u00e9es \u00e0 l'\u00e9tat de charge, la temp\u00e9rature, la consommation des \u00e9quipements auxiliaires, la marge de d\u00e9gradation et la logique de gestion du client sont autant de facteurs qui influent sur l'\u00e9nergie utilisable dans le cadre du projet.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-76dcca68 auto-p elementor-widget elementor-widget-heading\" data-id=\"76dcca68\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Pour une analyse plus approfondie des choix sp\u00e9cifiques \u00e0 chaque produit, redirigez les utilisateurs vers la page <strong><a href=\"https:\/\/www.solidess.com\/fr\/comment-selectionner-un-systeme-de-stockage-denergie-par-batterie-bess-exterieur-de-100-kw-215-kwh-pour-un-site-commercial-et-industriel-ci\/\" target=\"_blank\" style=\"color:#61ce70\">Guide de s\u00e9lection d'un syst\u00e8me de stockage d'\u00e9nergie par batterie (BESS) ext\u00e9rieur de 100 kW \/ 215 kWh<\/a><\/strong>. Cet article ne doit consid\u00e9rer l'armoire de 215 kWh que comme un \u00e9l\u00e9ment parmi d'autres dans le cadre d'une d\u00e9cision d'achat commerciale plus large.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-312c7e9e auto-h2 elementor-widget elementor-widget-heading\" data-id=\"312c7e9e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Quand faut-il envisager l'adoption d'un syst\u00e8me \u00e0 refroidissement liquide de 125 kVA \/ 261,24 kWh ?<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a1680f94 auto-p elementor-widget elementor-widget-heading\" data-id=\"a1680f94\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Le MegSolid Energon 261 est un syst\u00e8me de stockage d'\u00e9nergie C&amp;I \u00e0 refroidissement liquide d'une capacit\u00e9 de 261,24 kWh, \u00e9quip\u00e9 de cellules LFP de 314 Ah et d'une puissance nominale en courant alternatif de 125 kVA. Il convient d\u2019envisager son utilisation lorsque le projet n\u00e9cessite davantage d\u2019\u00e9nergie que ne le permet la configuration de 215,04 kWh, ou lorsque les exigences en mati\u00e8re de gestion thermique et de puissance CA justifient le recours \u00e0 une autre plateforme d\u2019armoires.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f42c5460 auto-p elementor-widget elementor-widget-heading\" data-id=\"f42c5460\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Le syst\u00e8me pr\u00e9sente une plage de tension alternative nominale de 400\/480 V CA avec une tol\u00e9rance de \u00b115% et une plage de r\u00e9glage du facteur de puissance comprise entre -1 et +1. Compte tenu de ces param\u00e8tres, il est important de d\u00e9finir avec pr\u00e9cision les besoins en courant alternatif du site avant d'\u00e9tablir un devis.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5220bd23 auto-p elementor-widget elementor-widget-heading\" data-id=\"5220bd23\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">\u00c9valuez l'itin\u00e9raire de 261,24 kWh lorsque :<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-97964f6c elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"97964f6c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">La demande en courant alternatif requise par le projet d\u00e9passe la limite pratique de s\u00e9lection d'une armoire de 100 kW.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Le client a besoin d'une fen\u00eatre \u00e9nerg\u00e9tique plus longue, tout en s'inscrivant dans une strat\u00e9gie de d\u00e9ploiement \u00e0 l'\u00e9chelle d'une armoire.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Les conditions ambiantes et d'exploitation font du refroidissement par liquide un \u00e9l\u00e9ment important \u00e0 prendre en compte dans le cadre du projet.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">L'EPC peut fournir le facteur de puissance, la tension, les donn\u00e9es de raccordement au r\u00e9seau et le sc\u00e9nario d'exploitation requis.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">L'appel d'offres permet de distinguer clairement la puissance en kW requise de la puissance apparente requise.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-775b39b8 auto-p elementor-widget elementor-widget-heading\" data-id=\"775b39b8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Ne pr\u00e9sentez pas le rendement maximal du syst\u00e8me de 90%, tel qu'il est publi\u00e9, comme un rendement aller-retour dans un mod\u00e8le de retour sur investissement. La fiche technique le d\u00e9crit comme le rendement maximal du syst\u00e8me, ce qui correspond \u00e0 un p\u00e9rim\u00e8tre de mesure diff\u00e9rent.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f48fefbf auto-p elementor-widget elementor-widget-heading\" data-id=\"f48fefbf\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">La prochaine \u00e9tape du processus d\u2019approvisionnement ne consiste pas \u00e0 \u201c s\u00e9lectionner 261 kWh \u201d. Il s\u2019agit de demander une confirmation du projet concernant la puissance CA utilisable, le profil de d\u00e9charge, les conditions de fonctionnement et les commandes. Le <strong><a href=\"https:\/\/www.solidess.com\/fr\/guide-des-rfq-pour-le-systeme-de-stockage-denergie-refroidi-par-liquide-de-261-kwh\/\" target=\"_blank\" style=\"color:#61ce70\">Guide pour les appels d'offres relatifs \u00e0 un syst\u00e8me de refroidissement par liquide de 261 kWh<\/a><\/strong> devrait \u00eatre utilis\u00e9 pour cette deuxi\u00e8me \u00e9tape de l'enqu\u00eate technique.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e8e4dca4 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"e8e4dca4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">La question du refroidissement doit \u00eatre prise en compte dans le cadre de la d\u00e9cision globale relative au stockage<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-afd67843 auto-p elementor-widget elementor-widget-heading\" data-id=\"afd67843\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Le refroidissement par air et le refroidissement par liquide sont des facteurs importants, mais ils ne remplacent pas l'analyse de la charge. Le mod\u00e8le ESSA0100B-0215 est r\u00e9pertori\u00e9 comme un syst\u00e8me intelligent \u00e0 refroidissement par air. Le syst\u00e8me de 261,24 kWh est quant \u00e0 lui \u00e0 refroidissement par liquide. Cette diff\u00e9rence doit \u00eatre \u00e9valu\u00e9e en tenant compte de la temp\u00e9rature sur site, de l'espace disponible pour l'installation, de l'acc\u00e8s pour la maintenance, de l'intensit\u00e9 d'utilisation et du profil de cycles quotidiens.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-56219d1b auto-p elementor-widget elementor-widget-heading\" data-id=\"56219d1b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Un acheteur ne devrait pas commencer par se demander : \u201c Quelle m\u00e9thode de refroidissement est la meilleure ? \u201d La bonne question est plut\u00f4t : <strong>\u201c L'alimentation en courant alternatif, la plage de consommation \u00e9nerg\u00e9tique et la conception thermique de cette armoire sont-elles adapt\u00e9es au cycle de fonctionnement que ce site imposera concr\u00e8tement ? \u201d<\/strong><\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-811789e8 auto-p elementor-widget elementor-widget-heading\" data-id=\"811789e8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Par exemple, un site \u00e0 charge mod\u00e9r\u00e9e disposant d'une plage de d\u00e9charge de 100 kW bien ma\u00eetris\u00e9e peut suivre une approche technique et \u00e9conomique diff\u00e9rente de celle d'un projet \u00e0 fort taux d'utilisation fonctionnant dans des conditions ambiantes plus exigeantes. Le refroidissement constitue un \u00e9l\u00e9ment parmi d'autres de l'argumentaire technique, mais ne saurait s'y substituer.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-590459e9 auto-p elementor-widget elementor-widget-heading\" data-id=\"590459e9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">L'actuel <strong><a href=\"https:\/\/www.solidess.com\/fr\/bess-a-refroidissement-par-liquide-ou-par-air\/\" target=\"_blank\" style=\"color:#61ce70\">Guide d'aide \u00e0 la d\u00e9cision concernant les syst\u00e8mes de stockage d'\u00e9nergie par batterie (BESS) \u00e0 refroidissement liquide et \u00e0 refroidissement par air<\/a><\/strong> aborde plus en d\u00e9tail la comparaison des syst\u00e8mes de gestion thermique. Cette page doit rester ax\u00e9e sur le choix de la solution commerciale la plus adapt\u00e9e en mati\u00e8re de stockage par batterie.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-01bf83fd auto-h2 elementor-widget elementor-widget-heading\" data-id=\"01bf83fd\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Calculer la dur\u00e9e d'ex\u00e9cution \u00e0 partir du r\u00e9sultat requis, puis ajouter les marges du projet<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-513e3f69 auto-p elementor-widget elementor-widget-heading\" data-id=\"513e3f69\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Voici un calcul simple \u00e0 effectuer au tout d\u00e9but : <strong>Dur\u00e9e de d\u00e9charge nominale = \u00e9nergie nominale \u00f7 puissance de d\u00e9charge requise<\/strong>. Cette formule n'est qu'un outil de s\u00e9lection. Elle ne permet pas de d\u00e9terminer une autonomie fiable, car elle ne tient pas compte des limites d'\u00e9tat de charge exploitables, des charges auxiliaires, de la marge de vieillissement, des effets de la temp\u00e9rature, des besoins de recharge et de la logique de fonctionnement du site.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e01c4b90 auto-p elementor-widget elementor-widget-heading\" data-id=\"e01c4b90\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">La proc\u00e9dure \u00e0 suivre est la suivante :<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-43b9aa14 elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"43b9aa14\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Identifiez la charge cible ou le pic d\u00e9passant la limite souhait\u00e9e d'injection dans le r\u00e9seau.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">D\u00e9finissez la puissance requise en kW ou en kVA pour chaque intervalle.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Calculez la dur\u00e9e de d\u00e9charge n\u00e9cessaire.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Appliquer les hypoth\u00e8ses relatives \u00e0 l'\u00e9nergie utilisable et \u00e0 la r\u00e9serve du projet.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">V\u00e9rifiez s'il convient d'opter pour une armoire, plusieurs armoires ou un parcours ESS en conteneur.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-eadca1ff auto-p elementor-widget elementor-widget-heading\" data-id=\"eadca1ff\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Si le site est \u00e9quip\u00e9 d\u2019une installation photovolta\u00efque, l\u2019alimentation photovolta\u00efque peut \u00eatre assur\u00e9e localement lorsque cela s\u2019av\u00e8re plus avantageux sur le plan commercial. L\u2019appel d\u2019offres pour le syst\u00e8me de stockage doit n\u00e9anmoins pr\u00e9ciser l\u2019interface photovolta\u00efque, le profil de charge pr\u00e9vu et les exigences en mati\u00e8re de contr\u00f4le, afin que le syst\u00e8me de stockage d\u2019\u00e9nergie par batterie (BESS) soit con\u00e7u en fonction du fonctionnement global du site.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-bda35c16 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"bda35c16\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Savoir quand une armoire n'appartient plus \u00e0 la bonne cat\u00e9gorie de produits<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-68917f96 auto-p elementor-widget elementor-widget-heading\" data-id=\"68917f96\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Une page consacr\u00e9e aux syst\u00e8mes de stockage par batterie \u00e0 usage commercial devrait aider les clients \u00e0 \u00e9viter de devoir int\u00e9grer syst\u00e9matiquement chaque projet dans une armoire. Orientez la discussion vers une solution plus vaste, de type \u00ab sur mesure \u00bb ou \u00ab en conteneur \u00bb, lorsque :<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a1f4d8d6 elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"a1f4d8d6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">La puissance requise ne peut pas \u00eatre fournie dans les limites de l\u2019alimentation CA de l\u2019armoire s\u00e9lectionn\u00e9e.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Le client a besoin d'une plage de d\u00e9charge nettement plus longue \u00e0 la charge requise.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Une extension future entra\u00eenerait une disposition des armoires peu fonctionnelle ou compliquerait l'int\u00e9gration sur site.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Ce projet n\u00e9cessite des commandes centralis\u00e9es, une architecture d'appareillage plus importante ou des interfaces \u00e0 l'\u00e9chelle des r\u00e9seaux de distribution.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">La logistique, l'encombrement sur site et la planification de la maintenance plaident en faveur d'un syst\u00e8me conteneuris\u00e9.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1e3b3e9a auto-p elementor-widget elementor-widget-heading\" data-id=\"1e3b3e9a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Cela ne signifie pas pour autant que tous les grands projets n\u00e9cessitent un conteneur. Il s'agit plut\u00f4t d'une invitation \u00e0 cesser de recourir \u00e0 la comparaison avec une armoire lorsque le projet a d\u00e9j\u00e0 chang\u00e9 de cat\u00e9gorie. Le <strong><a href=\"https:\/\/www.solidess.com\/fr\/armoires-modulaires-vs-ess-conteneurise\/\" target=\"_blank\" style=\"color:#61ce70\">Guide de d\u00e9ploiement des syst\u00e8mes de stockage d'\u00e9nergie (ESS) : armoires modulaires ou conteneurs ?<\/a><\/strong> peut aider un EPC \u00e0 d\u00e9finir cette transition.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0fc423bd auto-image elementor-widget elementor-widget-image\" data-id=\"0fc423bd\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"1536\" height=\"1152\" src=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/Commercial-Battery-Storage-Selection-Path-1536x1152.png\" class=\"attachment-1536x1536 size-1536x1536 wp-image-4728\" alt=\"Processus de s\u00e9lection des syst\u00e8mes de stockage d&#039;\u00e9nergie par batterie \u00e0 usage commercial MegSolid, illustrant comment les besoins en courant alternatif d\u00e9terminent la configuration pr\u00e9liminaire du syst\u00e8me de stockage d&#039;\u00e9nergie par batterie (BESS).\" srcset=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/Commercial-Battery-Storage-Selection-Path-1536x1152.png 1536w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/Commercial-Battery-Storage-Selection-Path-300x225.png 300w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/Commercial-Battery-Storage-Selection-Path-1024x768.png 1024w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/Commercial-Battery-Storage-Selection-Path-768x576.png 768w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/Commercial-Battery-Storage-Selection-Path-600x450.png 600w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/Commercial-Battery-Storage-Selection-Path.png 1600w\" sizes=\"(max-width: 1536px) 100vw, 1536px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-03c9151c auto-h2 elementor-widget elementor-widget-heading\" data-id=\"03c9151c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Transformez cette comparaison en un appel d'offres permettant d'\u00e9tablir un devis pr\u00e9cis<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0451a412 auto-p elementor-widget elementor-widget-heading\" data-id=\"0451a412\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Une demande bien formul\u00e9e fournit \u00e0 MegSolid suffisamment d'informations pour lui permettre de recommander une orientation technique, plut\u00f4t que de simplement envoyer une liste g\u00e9n\u00e9rique de produits. Veuillez inclure les \u00e9l\u00e9ments suivants dans votre demande :<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e39b3b6c elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"e39b3b6c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Emplacement du site et environnement d'installation<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Sch\u00e9ma unifilaire ou informations disponibles sur le raccordement<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Tension nominale, fr\u00e9quence et \u00e9tat du r\u00e9seau<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Donn\u00e9es de charge par intervalle et historique des pics de demande<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Liste des charges critiques et d\u00e9lestage autoris\u00e9<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Dur\u00e9e requise pour la r\u00e9serve ou l'\u00e9cr\u00eatement des pointes<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Modes de fonctionnement requis : raccordement au r\u00e9seau, soutien au g\u00e9n\u00e9rateur, secours ou micro-r\u00e9seau<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Informations sur le facteur de puissance et la charge du moteur<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Encombrement d'installation disponible et restrictions d'acc\u00e8s<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Hypoth\u00e8ses concernant l'\u00e9volution future de la charge<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Exigences relatives \u00e0 la mise en service, aux essais FAT et SAT, ainsi qu'\u00e0 la documentation<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b56aa6e6 auto-p elementor-widget elementor-widget-heading\" data-id=\"b56aa6e6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Le BESS et le PCS doivent \u00eatre consid\u00e9r\u00e9s comme un seul et m\u00eame syst\u00e8me d'exploitation. Pour les principes de conception du c\u00f4t\u00e9 courant alternatif, utilisez le <strong><a href=\"https:\/\/www.solidess.com\/fr\/ingenierie-des-onduleurs-pcs\/\" target=\"_blank\" style=\"color:#61ce70\">Ouvrage de r\u00e9f\u00e9rence sur l'ing\u00e9nierie de la conversion d'\u00e9nergie et de la stabilisation du r\u00e9seau<\/a><\/strong>. Pour obtenir des informations plus d\u00e9taill\u00e9es sur la documentation, la qualification des fournisseurs et les contr\u00f4les de livraison, consultez le <strong><a href=\"https:\/\/www.solidess.com\/fr\/achat-de-stockage-denergie-commercial\/\" target=\"_blank\" style=\"color:#61ce70\">processus de diligence raisonnable pour l'approvisionnement en solutions de stockage commercial<\/a><\/strong>.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7c68995a elementor-tablet-align-center elementor-align-center auto-cta elementor-widget elementor-widget-button\" data-id=\"7c68995a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"#elementor-action%3Aaction%3Dpopup%3Aopen%26settings%3DeyJpZCI6Ijk0OCIsInRvZ2dsZSI6ZmFsc2V9\" target=\"_blank\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Demander une analyse du profil de charge d'un client professionnel<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4e5e77ea auto-h2 elementor-widget elementor-widget-heading\" data-id=\"4e5e77ea\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\"> Exiger des justificatifs avant d'approuver l'installation d'un syst\u00e8me commercial de stockage d'\u00e9nergie par batterie<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c6c8b431 auto-p elementor-widget elementor-widget-heading\" data-id=\"c6c8b431\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Un devis ne constitue pas le document technique d\u00e9finitif. Avant de le valider, le client doit v\u00e9rifier le mod\u00e8le exact fourni, la puissance en courant alternatif, la configuration des batteries, le mode de refroidissement, les interfaces de communication, l'\u00e9tendue de la protection ainsi que les certifications applicables au syst\u00e8me livr\u00e9.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7fa58cb8 auto-p elementor-widget elementor-widget-heading\" data-id=\"7fa58cb8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Pour un projet g\u00e9r\u00e9 en EPC, la cha\u00eene de tra\u00e7abilit\u00e9 doit inclure :<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7ea0ba8a auto-table elementor-widget elementor-widget-text-editor\" data-id=\"7ea0ba8a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"cea-table-wrap\"><table><thead><tr><th>\u00c9tape d'approbation<\/th><th>Ce qu\u2019il faut v\u00e9rifier<\/th><\/tr><\/thead><tbody><tr><td>Proposition<\/td><td>Puissance requise (kW, kVA), consommation (kWh), dur\u00e9e et mode de fonctionnement<\/td><\/tr><tr><td>Analyse technique<\/td><td>Sch\u00e9ma unifilaire, tension d'alimentation, logique de commande et interfaces de protection<\/td><\/tr><tr><td>R\u00e9ception en usine<\/td><td>Contr\u00f4les fonctionnels par rapport au cahier des charges technique approuv\u00e9<\/td><\/tr><tr><td>Validation de l'exp\u00e9dition<\/td><td>R\u00e9f\u00e9rences des mod\u00e8les, bordereau d'exp\u00e9dition, documents et configuration convenue<\/td><\/tr><tr><td>Mise en service<\/td><td>Configuration du site, communications et v\u00e9rification du mode de fonctionnement<\/td><\/tr><\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2dd747d7 auto-p elementor-widget elementor-widget-heading\" data-id=\"2dd747d7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Utilisez le <strong><a href=\"https:\/\/www.solidess.com\/fr\/guide-dessai-de-reception-en-usine-de-bess\/\" target=\"_blank\" style=\"color:#61ce70\">Guide \u00e0 l'intention des t\u00e9moins lors des essais de r\u00e9ception en usine du syst\u00e8me BESS<\/a><\/strong> afin de d\u00e9finir les \u00e9l\u00e9ments \u00e0 v\u00e9rifier avant l'exp\u00e9dition. Les exigences en mati\u00e8re de certification doivent \u00eatre v\u00e9rifi\u00e9es en fonction du pays du projet, de l'autorit\u00e9 comp\u00e9tente et des conditions d'installation ; les <strong><a href=\"https:\/\/www.solidess.com\/fr\/guide-de-lepc-sur-la-conformite-aux-normes-ul-9540a-et-cei-62619\/\" target=\"_blank\" style=\"color:#61ce70\">R\u00e9f\u00e9rence de certification BESS pour les EPC<\/a><\/strong> explique pourquoi une liste de certificats g\u00e9n\u00e9rique ne suffit pas pour tous les projets.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ffd3262f auto-h2 elementor-widget elementor-widget-heading\" data-id=\"ffd3262f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">La d\u00e9cision commerciale en une phrase<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a3254b5a auto-p elementor-widget elementor-widget-heading\" data-id=\"a3254b5a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Optez pour la solution 100 kW \/ 215,04 kWh lorsque le site pr\u00e9sente un besoin de puissance de sortie bien d\u00e9fini de classe 100 kW et une plage de puissance v\u00e9rifi\u00e9e. \u00c9valuez la solution \u00e0 refroidissement liquide de 125 kVA \/ 261,24 kWh lorsque le projet n\u00e9cessite davantage d\u2019\u00e9nergie ou une configuration diff\u00e9rente en mati\u00e8re de courant alternatif et de gestion thermique ; veillez toutefois \u00e0 confirmer la puissance r\u00e9elle requise (en kW) au facteur de puissance du projet avant de la s\u00e9lectionner.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-184f8441 auto-p elementor-widget elementor-widget-heading\" data-id=\"184f8441\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">La prochaine \u00e9tape consiste \u00e0 examiner le profil de charge, et non \u00e0 \u00e9tablir un devis bas\u00e9 uniquement sur la capacit\u00e9.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-060ee00b elementor-tablet-align-center elementor-align-center auto-cta elementor-widget elementor-widget-button\" data-id=\"060ee00b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"#elementor-action%3Aaction%3Dpopup%3Aopen%26settings%3DeyJpZCI6Ijk0OCIsInRvZ2dsZSI6ZmFsc2V9\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Envoyez un e-mail \u00e0 MegSolid pour obtenir une \u00e9valuation d'un syst\u00e8me de stockage d'\u00e9nergie par batterie (BESS) de 215 kWh \/ 261 kWh<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-27e94ccb auto-p elementor-widget elementor-widget-heading\" data-id=\"27e94ccb\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Pour recevoir la liste de contr\u00f4le relative \u00e0 l'appel d'offres pour le syst\u00e8me de stockage d'\u00e9nergie par batterie (BESS) de 215 kWh \/ 261 kWh, envoyez un e-mail \u00e0 <strong>sfhq2008@gmail.com<\/strong> avec le pays concern\u00e9 par le projet, le profil de charge par intervalle, les puissances requises en kW et en kVA, la dur\u00e9e pr\u00e9vue, le sch\u00e9ma unifilaire, le facteur de puissance, les conditions d'installation et le calendrier de livraison.<\/p>\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-191c9ef3 auto-faq e-flex e-con-boxed e-con e-child\" data-id=\"191c9ef3\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-5416b16d elementor-widget elementor-widget-heading\" data-id=\"5416b16d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">FAQ<\/h2>\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-341f19b4 e-con-full e-flex e-con e-child\" data-id=\"341f19b4\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a8feef2a elementor-widget elementor-widget-n-accordion\" data-id=\"a8feef2a\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;default_state&quot;:&quot;all_collapsed&quot;,&quot;max_items_expended&quot;:&quot;one&quot;,&quot;n_accordion_animation_duration&quot;:{&quot;unit&quot;:&quot;ms&quot;,&quot;size&quot;:400,&quot;sizes&quot;:[]}}\" data-widget_type=\"nested-accordion.default\">\n\t\t\t\t\t\t\t<div class=\"e-n-accordion\" aria-label=\"Accord\u00e9on. Ouvrez les liens \u00e0 l&#039;aide de la touche Entr\u00e9e ou de la barre d&#039;espace, fermez-les avec la touche \u00c9chap et naviguez \u00e0 l&#039;aide des touches fl\u00e9ch\u00e9es.\">\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2830\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"1\" tabindex=\"0\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2830\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Comment choisir un syst\u00e8me de stockage par batterie \u00e0 usage industriel pour une usine ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2830\" class=\"elementor-element elementor-element-7bee5a98 e-con-full e-flex e-con e-child\" data-id=\"7bee5a98\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2830\" class=\"elementor-element elementor-element-5aed806e e-con-full e-flex e-con e-child\" data-id=\"5aed806e\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-66153045 elementor-widget elementor-widget-heading\" data-id=\"66153045\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Commencez par les donn\u00e9es de charge sur 15 minutes, la puissance maximale en kW ou kVA \u00e0 prendre en charge, la dur\u00e9e de d\u00e9charge requise et la liste des charges critiques. Comparez ensuite la capacit\u00e9 CA requise et l'\u00e9nergie utilisable avec la configuration propos\u00e9e pour le syst\u00e8me de stockage d'\u00e9nergie par batterie (BESS).<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2831\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"2\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2831\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Un syst\u00e8me de stockage d'\u00e9nergie par batterie (BESS) de 215 kWh est-il adapt\u00e9 \u00e0 une charge commerciale de 100 kW ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2831\" class=\"elementor-element elementor-element-564d8e3f e-con-full e-flex e-con e-child\" data-id=\"564d8e3f\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2831\" class=\"elementor-element elementor-element-642131fa e-con-full e-flex e-con e-child\" data-id=\"642131fa\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-229b840c elementor-widget elementor-widget-heading\" data-id=\"229b840c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Cette estimation peut \u00eatre r\u00e9alis\u00e9e lorsque la puissance de d\u00e9charge requise de la batterie reste inf\u00e9rieure \u00e0 la puissance nominale de 100 kW en courant alternatif et que la dur\u00e9e requise est compatible avec les hypoth\u00e8ses relatives \u00e0 l'\u00e9nergie utilisable du projet. La capacit\u00e9 nominale en kWh ne suffit pas \u00e0 elle seule \u00e0 garantir l'autonomie.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2832\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"3\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2832\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Est-ce que \u00ab 125 kVA \u00bb signifie qu'un syst\u00e8me de stockage d'\u00e9nergie par batterie (BESS) peut toujours fournir 125 kW ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2832\" class=\"elementor-element elementor-element-dd0554c7 e-con-full e-flex e-con e-child\" data-id=\"dd0554c7\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2832\" class=\"elementor-element elementor-element-cf783a8c e-con-full e-flex e-con e-child\" data-id=\"cf783a8c\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-3e1606ec elementor-widget elementor-widget-heading\" data-id=\"3e1606ec\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Non. Le kVA correspond \u00e0 la puissance apparente, tandis que le kW d\u00e9pend du facteur de puissance en service et de la configuration approuv\u00e9e du syst\u00e8me. L'appel d'offres doit pr\u00e9ciser la puissance r\u00e9elle requise.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2833\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"4\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2833\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Dois-je choisir un syst\u00e8me de stockage d'\u00e9nergie (BESS) en fonction de sa capacit\u00e9 \u00e9nerg\u00e9tique ou de sa puissance nominale ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2833\" class=\"elementor-element elementor-element-837975ba e-con-full e-flex e-con e-child\" data-id=\"837975ba\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2833\" class=\"elementor-element elementor-element-6459e356 e-con-full e-flex e-con e-child\" data-id=\"6459e356\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-fa4b7572 elementor-widget elementor-widget-heading\" data-id=\"fa4b7572\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Ces deux \u00e9l\u00e9ments sont indispensables. La puissance permet de d\u00e9terminer si le syst\u00e8me de stockage d'\u00e9nergie par batterie (BESS) est capable de prendre en charge la charge \u00e0 un moment donn\u00e9 ; l'\u00e9nergie permet de d\u00e9terminer pendant combien de temps il peut le faire.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2834\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"5\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2834\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Quelles donn\u00e9es doivent figurer dans un appel d'offres portant sur un syst\u00e8me commercial de stockage par batterie ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2834\" class=\"elementor-element elementor-element-4b6764ab e-con-full e-flex e-con e-child\" data-id=\"4b6764ab\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2834\" class=\"elementor-element elementor-element-4d822154 e-con-full e-flex e-con e-child\" data-id=\"4d822154\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-cf46e780 elementor-widget elementor-widget-heading\" data-id=\"cf46e780\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Veuillez inclure les donn\u00e9es relatives aux charges par intervalle, \u00e0 la tension, \u00e0 la fr\u00e9quence, au mode de fonctionnement cible, \u00e0 la dur\u00e9e de d\u00e9charge requise, au facteur de puissance, \u00e0 la temp\u00e9rature sur site, \u00e0 l'espace d'installation, aux charges critiques et aux projets d'extension futurs.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2835\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"6\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2835\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Le mod\u00e8le ESSA0100B-0215 est-il refroidi par liquide ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2835\" class=\"elementor-element elementor-element-d8a8a6a6 e-con-full e-flex e-con e-child\" data-id=\"d8a8a6a6\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2835\" class=\"elementor-element elementor-element-6aa7c596 e-con-full e-flex e-con e-child\" data-id=\"6aa7c596\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-edbc0437 elementor-widget elementor-widget-heading\" data-id=\"edbc0437\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Non. D'apr\u00e8s les informations actuelles sur le mod\u00e8le, l'ESSA0100B-0215 est une armoire ext\u00e9rieure intelligente \u00e0 refroidissement par air.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2836\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"7\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2836\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Dans quels cas un acheteur devrait-il envisager l'acquisition d'un syst\u00e8me de stockage d'\u00e9nergie par batterie (BESS) \u00e0 refroidissement liquide d'une capacit\u00e9 de 261,24 kWh ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2836\" class=\"elementor-element elementor-element-850f35a8 e-con-full e-flex e-con e-child\" data-id=\"850f35a8\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2836\" class=\"elementor-element elementor-element-b94319cd e-con-full e-flex e-con e-child\" data-id=\"b94319cd\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-cfcba741 elementor-widget elementor-widget-heading\" data-id=\"cfcba741\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">\u00c9valuez cette option lorsque le projet n\u00e9cessite davantage d'\u00e9nergie que ne le permet la configuration de 215,04 kWh, ou lorsque les exigences en mati\u00e8re de puissance de climatisation et de gestion thermique imposent l'utilisation d'une armoire \u00e0 refroidissement par liquide. La puissance requise en kW, au facteur de puissance du projet, doit encore \u00eatre confirm\u00e9e.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2837\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"8\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2837\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Une batterie plus grande garantit-elle automatiquement une meilleure autonomie ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2837\" class=\"elementor-element elementor-element-4d37e7d0 e-con-full e-flex e-con e-child\" data-id=\"4d37e7d0\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2837\" class=\"elementor-element elementor-element-2441fd57 e-con-full e-flex e-con e-child\" data-id=\"2441fd57\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-23961d3e elementor-widget elementor-widget-heading\" data-id=\"23961d3e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Non. Les performances de l'alimentation de secours d\u00e9pendent de la capacit\u00e9 du syst\u00e8me \u00e0 fournir le courant alternatif requis, de la dur\u00e9e pendant laquelle la charge doit fonctionner et des charges qui restent connect\u00e9es pendant l'incident.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2838\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"9\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2838\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Quand dois-je passer d'un syst\u00e8me BESS en armoire \u00e0 un syst\u00e8me de stockage en conteneurs ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2838\" class=\"elementor-element elementor-element-31017abf e-con-full e-flex e-con e-child\" data-id=\"31017abf\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2838\" class=\"elementor-element elementor-element-dfe5724a e-con-full e-flex e-con e-child\" data-id=\"dfe5724a\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-6e94c73f elementor-widget elementor-widget-heading\" data-id=\"6e94c73f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Optez pour une solution d'\u00e9valuation bas\u00e9e sur des conteneurs modulaires lorsque la capacit\u00e9 de climatisation des armoires, la dur\u00e9e requise, les pr\u00e9visions d'extension, l'int\u00e9gration sur site ou les commandes centralis\u00e9es ne r\u00e9pondent plus efficacement aux besoins du projet.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2839\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"10\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2839\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Quels sont les \u00e9l\u00e9ments \u00e0 v\u00e9rifier lors des essais de r\u00e9ception en usine du syst\u00e8me BESS ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2839\" class=\"elementor-element elementor-element-2ddc4fa1 e-con-full e-flex e-con e-child\" data-id=\"2ddc4fa1\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2839\" class=\"elementor-element elementor-element-835caac7 e-con-full e-flex e-con e-child\" data-id=\"835caac7\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-37a41f4b elementor-widget elementor-widget-heading\" data-id=\"37a41f4b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Avant de valider l'exp\u00e9dition, v\u00e9rifiez le mod\u00e8le et la configuration fournis, les interfaces homologu\u00e9es, les fonctions de protection et de contr\u00f4le, les communications, la documentation ainsi que l'\u00e9tendue des essais convenue.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-28310\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"11\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-28310\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> \u00c0 quoi sert le stockage commercial par batterie ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-28310\" class=\"elementor-element elementor-element-bb94b04b e-con-full e-flex e-con e-child\" data-id=\"bb94b04b\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-28310\" class=\"elementor-element elementor-element-656f7f01 e-con-full e-flex e-con e-child\" data-id=\"656f7f01\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-f4f2cfff elementor-widget elementor-widget-heading\" data-id=\"f4f2cfff\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Les syst\u00e8mes de stockage par batterie \u00e0 usage commercial peuvent permettre de lisser les pics de consommation, d\u2019assurer l\u2019alimentation de secours des charges critiques, de d\u00e9caler la consommation d\u2019\u00e9nergie dans le temps, de soutenir le fonctionnement des groupes \u00e9lectrog\u00e8nes et d\u2019assurer certaines fonctions de micro-r\u00e9seau, \u00e0 condition que le syst\u00e8me soit adapt\u00e9 au profil de consommation \u00e9lectrique du site.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-28311\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"12\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-28311\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Quel syst\u00e8me de stockage d'\u00e9nergie par batterie (BESS) commercial convient \u00e0 un site de type C&amp;I d'une puissance de l'ordre de 100 kW ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-28311\" class=\"elementor-element elementor-element-1e4b248b e-con-full e-flex e-con e-child\" data-id=\"1e4b248b\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-28311\" class=\"elementor-element elementor-element-af3413e3 e-con-full e-flex e-con e-child\" data-id=\"af3413e3\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-8c0bd493 elementor-widget elementor-widget-heading\" data-id=\"8c0bd493\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Une armoire ext\u00e9rieure de 100 kW \/ 215,04 kWh peut \u00eatre envisag\u00e9e lorsque la puissance de d\u00e9charge requise ne d\u00e9passe pas 100 kW et que le profil de charge correspond \u00e0 la plage d'\u00e9nergie disponible. Le choix d\u00e9finitif n\u00e9cessite une analyse sp\u00e9cifique au projet.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-28312\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"13\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-28312\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Quelle est la diff\u00e9rence entre un syst\u00e8me de stockage d'\u00e9nergie par batterie \u00e0 usage commercial et un syst\u00e8me BESS en conteneur ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-28312\" class=\"elementor-element elementor-element-a757be85 e-con-full e-flex e-con e-child\" data-id=\"a757be85\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-28312\" class=\"elementor-element elementor-element-778e2621 e-con-full e-flex e-con e-child\" data-id=\"778e2621\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-4c850a23 elementor-widget elementor-widget-heading\" data-id=\"4c850a23\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Les armoires commerciales sont g\u00e9n\u00e9ralement \u00e9valu\u00e9es en fonction d'exigences sp\u00e9cifiques au site, tandis que les solutions BESS en conteneurs sont utilis\u00e9es lorsque des besoins en puissance plus \u00e9lev\u00e9s, une dur\u00e9e plus longue, une int\u00e9gration centralis\u00e9e ou des exigences d'extension plus importantes modifient la port\u00e9e du projet.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-28313\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"14\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-28313\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Comment comparer un BESS de 100 kW \/ 215,04 kWh avec un BESS de 125 kVA \/ 261,24 kWh ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-28313\" class=\"elementor-element elementor-element-05394740 e-con-full e-flex e-con e-child\" data-id=\"05394740\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-28313\" class=\"elementor-element elementor-element-65cfbbba e-con-full e-flex e-con e-child\" data-id=\"65cfbbba\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-abfa4d3f elementor-widget elementor-widget-heading\" data-id=\"abfa4d3f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Comparez la puissance alternative requise, le facteur de puissance du projet, la dur\u00e9e de d\u00e9charge, les hypoth\u00e8ses d'\u00e9nergie utilisable, les exigences de gestion thermique et les plans d'expansion future. Ne traitez pas 125 kVA comme une valeur fixe de 125 kW sans confirmer le point de fonctionnement du projet.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-28314\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"15\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-28314\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> L'armoire ext\u00e9rieure de 215,04 kWh convient-elle \u00e0 tous les projets de secours commerciaux ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-28314\" class=\"elementor-element elementor-element-efa64f71 e-con-full e-flex e-con e-child\" data-id=\"efa64f71\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-28314\" class=\"elementor-element elementor-element-137eb584 e-con-full e-flex e-con e-child\" data-id=\"137eb584\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-f5036cb4 elementor-widget elementor-widget-heading\" data-id=\"f5036cb4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Non. L'ESSA0100B-0215 doit \u00eatre \u00e9valu\u00e9 l\u00e0 o\u00f9 la puissance de d\u00e9charge de la batterie requise reste dans les limites de sa puissance nominale de 100 kW CA et o\u00f9 le profil de charge v\u00e9rifi\u00e9 prend en charge la fen\u00eatre d'\u00e9nergie requise.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-28315\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"16\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-28315\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Quels documents un EPC doit-il fournir avant de demander un devis pour un syst\u00e8me de stockage par batterie \u00e0 usage commercial ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-28315\" class=\"elementor-element elementor-element-499f44e0 e-con-full e-flex e-con e-child\" data-id=\"499f44e0\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-28315\" class=\"elementor-element elementor-element-fcef3fea e-con-full e-flex e-con e-child\" data-id=\"fcef3fea\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-bea959ba elementor-widget elementor-widget-heading\" data-id=\"bea959ba\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Veuillez fournir les donn\u00e9es relatives \u00e0 la charge par intervalle, les valeurs requises en kW et kVA, le facteur de puissance, la tension, la fr\u00e9quence, la dur\u00e9e requise, la liste des charges critiques, le mode de fonctionnement, les conditions ambiantes, les contraintes d'installation et les besoins futurs en mati\u00e8re d'extension.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Comparez une armoire d'ext\u00e9rieur de 100 kW \/ 215,04 kWh \u00e0 un syst\u00e8me C&amp;I \u00e0 refroidissement liquide de 125 kVA \/ 261,24 kWh. V\u00e9rifiez que la puissance alternative, le facteur de puissance, la dur\u00e9e et les conditions thermiques correspondent avant de demander un devis pour un syst\u00e8me de stockage par batterie \u00e0 usage commercial.<\/p>","protected":false},"author":4,"featured_media":4739,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"_joinchat":[],"footnotes":""},"categories":[1,712],"tags":[319,320,321,260,185,317,294,318,142,36],"class_list":["post-4729","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-bess","category-bess-product-comparisons","tag-215kwh-bess","tag-261kwh-energy-storage-system","tag-bess-sizing","tag-ci-battery-storage","tag-commercial-battery-storage","tag-commercial-battery-storage-systems","tag-commercial-bess","tag-commercial-energy-storage-system","tag-epc-procurement","tag-MegSolid"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/posts\/4729","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/comments?post=4729"}],"version-history":[{"count":12,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/posts\/4729\/revisions"}],"predecessor-version":[{"id":4743,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/posts\/4729\/revisions\/4743"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/media\/4739"}],"wp:attachment":[{"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/media?parent=4729"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/categories?post=4729"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/tags?post=4729"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}