{"id":4766,"date":"2026-08-14T09:16:48","date_gmt":"2026-08-14T01:16:48","guid":{"rendered":"https:\/\/www.solidess.com\/?p=4766"},"modified":"2026-10-14T03:05:23","modified_gmt":"2026-10-13T19:05:23","slug":"aptitude-au-raccordement-dun-systeme-de-stockage-denergie-commercial","status":"publish","type":"post","link":"https:\/\/www.solidess.com\/fr\/commercial-energy-storage-system-interconnection-readiness\/","title":{"rendered":"\u00c9tat de pr\u00e9paration \u00e0 le raccordement des syst\u00e8mes commerciaux de stockage d'\u00e9nergie"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"4766\" class=\"elementor elementor-4766\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-bf4793c e-con-full auto-article-root e-flex e-con e-parent\" data-id=\"bf4793c\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-cbcdc4f8 auto-p elementor-widget elementor-widget-heading\" data-id=\"cbcdc4f8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">A battery order does not solve a blocked connection. If the transformer is full, the PCC limit is unclear or the switchboard cannot accept the feeder, your commercial energy storage system can arrive before the site is ready to use it. Start with interval load data, the SLD, upstream equipment limits and the operating target. MegSolid can use that defined duty to review the battery-and-PCS route before procurement locks in the wrong configuration.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ccce4c3a auto-image elementor-widget elementor-widget-image\" data-id=\"ccce4c3a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"768\" height=\"768\" src=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/Commercial-Energy-Storage-System-Interconnection-Readiness.png\" class=\"attachment-1536x1536 size-1536x1536 wp-image-4763\" alt=\"MegSolid MEGA PCS, syst\u00e8me de stockage d&#039;\u00e9nergie par batterie (BESS) ESSC en conteneur, rack modulaire PMA PCS, transformateur et PCC : aper\u00e7u de l&#039;interconnexion d&#039;un syst\u00e8me BESS commercial\" srcset=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/Commercial-Energy-Storage-System-Interconnection-Readiness.png 768w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/Commercial-Energy-Storage-System-Interconnection-Readiness-300x300.png 300w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/Commercial-Energy-Storage-System-Interconnection-Readiness-150x150.png 150w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/Commercial-Energy-Storage-System-Interconnection-Readiness-600x600.png 600w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/Commercial-Energy-Storage-System-Interconnection-Readiness-100x100.png 100w\" sizes=\"(max-width: 768px) 100vw, 768px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-297715a9 auto-p elementor-widget elementor-widget-heading\" data-id=\"297715a9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">For the owner, this review protects the promised operating duty. For the EPC, it exposes the feeder, protection and control work that must be priced. For procurement, it turns three competing catalogue quotes into offers measured against one site requirement. Use the following inputs to force that clarity before award.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f9e465ba auto-table elementor-widget elementor-widget-text-editor\" data-id=\"f9e465ba\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"cea-table-wrap\"><table><thead><tr><th>D\u00e9cision de parvenir \u00e0 un accord<\/th><th>Justificatifs relatifs au site requis<\/th><th>R\u00e9duction des risques li\u00e9s au projet<\/th><\/tr><\/thead><tbody><tr><td>T\u00e2ches obligatoires de d\u00e9chargement et de chargement<\/td><td>Profil de charge par intervalle, niveau de demande cible et plage de fonctionnement<\/td><td>Une plage de puissance et de dur\u00e9e qui refl\u00e8te les conditions r\u00e9elles d'utilisation<\/td><\/tr><tr><td>P\u00e9rim\u00e8tre d'exploitation du PCC<\/td><td>Sch\u00e9ma unifilaire de contr\u00f4le, emplacement du compteur de consommation et limites d'exportation\/importation<\/td><td>Un champ d'application align\u00e9 sur le point \u00e9lectrique qui r\u00e9git l'installation<\/td><\/tr><tr><td>Parcours des transformateurs et des appareillages de commutation<\/td><td>Donn\u00e9es figurant sur la plaque signal\u00e9tique, capacit\u00e9 disponible, niveau de tension et informations relatives \u00e0 la protection<\/td><td>Identification pr\u00e9coce des contraintes en amont et des travaux relatifs aux \u00e9quipements auxiliaires<\/td><\/tr><tr><td>Fonctionnalit\u00e9 PCS<\/td><td>Puissance requise (kW, kVA), plage de facteur de puissance et priorit\u00e9 de commande<\/td><td>Une plage de fonctionnement r\u00e9aliste du courant alternatif<\/td><\/tr><tr><td>Preuves de transfert<\/td><td>Crit\u00e8res d'acceptation, propri\u00e9t\u00e9 des donn\u00e9es et registres de mise en service<\/td><td>Un parcours tra\u00e7able, de la proposition \u00e0 la r\u00e9ception du chantier<\/td><\/tr><\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-30e9cc25 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"30e9cc25\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">D\u00e9finir l'enveloppe d'interconnexion et l'enregistrement de charge<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-cd579519 auto-p elementor-widget elementor-widget-heading\" data-id=\"cd579519\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">L'\u00e9tude d'un raccordement commence par la limite \u00e9lectrique qui rev\u00eat une importance commerciale. Pour de nombreux projets \u00ab derri\u00e8re le compteur \u00bb, il s\u2019agit du point de couplage commun ou de la limite du compteur de revenus de l\u2019installation. Le sch\u00e9ma unifilaire approuv\u00e9 doit indiquer l\u2019interface avec le r\u00e9seau public, le transformateur, le tableau principal, le point de raccordement du syst\u00e8me de stockage d\u2019\u00e9nergie par batterie (BESS), les principaux bus de charge et toute installation de production d\u00e9j\u00e0 raccord\u00e9e. Ce sch\u00e9ma fournit \u00e0 toutes les parties une r\u00e9f\u00e9rence unique concernant le flux d\u2019\u00e9nergie propos\u00e9.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-cc44e084 auto-p elementor-widget elementor-widget-heading\" data-id=\"cc44e084\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Les donn\u00e9es de charge par intervalle indiquent ensuite \u00e0 quel moment le site a besoin d'un soutien. Une facture mensuelle fournit un aper\u00e7u utile, tandis que les enregistrements \u00e0 intervalles de 15 minutes ou moins r\u00e9v\u00e8lent la forme des pics de demande, la charge de base, les variations, les changements d'\u00e9quipe et les \u00e9v\u00e9nements r\u00e9currents. Cette distinction est importante lorsqu'un site pr\u00e9voit une r\u00e9gulation de la demande, un soutien de secours, une coordination des groupes \u00e9lectrog\u00e8nes ou une recharge programm\u00e9e. Le <strong><a href=\"https:\/\/www.solidess.com\/fr\/achat-de-stockage-denergie-commercial\/\" target=\"_blank\" style=\"color:#61ce70\">Guide d'achat de syst\u00e8mes de stockage d'\u00e9nergie \u00e0 usage commercial<\/a><\/strong> explique en quoi ces donn\u00e9es op\u00e9rationnelles permettent une comparaison rigoureuse des fournisseurs.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-651b559e auto-p elementor-widget elementor-widget-heading\" data-id=\"651b559e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Les relev\u00e9s \u00e9nerg\u00e9tiques mensuels r\u00e9sument la consommation. Les relev\u00e9s par intervalle mettent en \u00e9vidence les pics de puissance (kW) et de puissance apparente (kVA) de courte dur\u00e9e qui r\u00e9gissent le fonctionnement d'un syst\u00e8me de stockage commercial. Un site pr\u00e9sentant une consommation mensuelle mod\u00e9r\u00e9e peut n\u00e9anmoins conna\u00eetre des intervalles r\u00e9p\u00e9t\u00e9s de forte demande li\u00e9s \u00e0 une s\u00e9quence de production, \u00e0 un bloc de charge ou \u00e0 un processus entra\u00een\u00e9 par un moteur. C'est pourquoi la base de conception doit identifier l'\u00e9v\u00e9nement que le syst\u00e8me de stockage d'\u00e9nergie par batterie (BESS) est cens\u00e9 g\u00e9rer, plut\u00f4t que de consid\u00e9rer la consommation annuelle comme l'exigence d'exploitation.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-90714aaa auto-h3 elementor-widget elementor-widget-heading\" data-id=\"90714aaa\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Donn\u00e9es minimales relatives au site pour une premi\u00e8re \u00e9tude technique<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7dcab163 elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"7dcab163\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">\ud83d\udcc8 Donn\u00e9es relatives \u00e0 la consommation en kW et en kVA par intervalle, couvrant des journ\u00e9es d'exploitation repr\u00e9sentatives, les variations saisonni\u00e8res et les pics de consommation connus.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">\ud83d\udccd Un sch\u00e9ma unifilaire \u00e0 jour indiquant le PCC, le compteur de consommation, le transformateur et le raccordement pr\u00e9vu du syst\u00e8me de stockage d'\u00e9nergie par batterie (BESS).<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">\u26a1 Plaque signal\u00e9tique du transformateur, tensions primaire et secondaire, historique de la charge et espace disponible dans le tableau \u00e9lectrique.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">\ud83e\udded Limites d'importation\/exportation, p\u00e9riodes tarifaires, objectif de r\u00e9gulation de la demande et modes de fonctionnement requis.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">\ud83c\udfed Les charges importantes li\u00e9es aux moteurs, aux entra\u00eenements, au soudage, \u00e0 la recharge, aux syst\u00e8mes CVC, aux installations photovolta\u00efques ou aux groupes \u00e9lectrog\u00e8nes qui g\u00e9n\u00e8rent des variations brusques de courant ou une consommation de puissance r\u00e9active.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">\ud83d\udee0\ufe0f Param\u00e8tres de protection, configuration des compteurs, architecture de communication et exigences en mati\u00e8re d'acceptation par les propri\u00e9taires.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-94b7c423 auto-table elementor-widget elementor-widget-text-editor\" data-id=\"94b7c423\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"cea-table-wrap\"><table><thead><tr><th>Champ de donn\u00e9es<\/th><th>Pourquoi cela modifie-t-il le champ d'application du BESS ?<\/th><th>Question d'examen pratique<\/th><\/tr><\/thead><tbody><tr><td>Puissance de pointe (kW)<\/td><td>D\u00e9finit l'\u00e9cart de puissance active que le syst\u00e8me de stockage d'\u00e9nergie par batterie (BESS) pourrait devoir combler<\/td><td>Quels \u00e9v\u00e9nements li\u00e9s \u00e0 la charge sont \u00e0 l'origine du probl\u00e8me de demande commerciale ?<\/td><\/tr><tr><td>kVA par intervalle et facteur de puissance<\/td><td>Indique la charge en puissance apparente d\u00e9tect\u00e9e par le PCS et la centrale en amont<\/td><td>La puissance r\u00e9active consomme-t-elle une partie de l'enveloppe PCS disponible ?<\/td><\/tr><tr><td>Limite cible du PCC<\/td><td>D\u00e9finit le point de contr\u00f4le de r\u00e9partition<\/td><td>Quelle valeur du compteur d\u00e9clenche la commande de charge ou de d\u00e9charge ?<\/td><\/tr><tr><td>Dur\u00e9e de l'\u00e9v\u00e9nement de chargement<\/td><td>D\u00e9finit la fen\u00eatre \u00e9nerg\u00e9tique pr\u00e9liminaire<\/td><td>Combien de temps dure chaque pic ou chaque \u00e9v\u00e9nement de charge critique ?<\/td><\/tr><tr><td>Charge du transformateur<\/td><td>Indique si le BESS est cens\u00e9 prendre en charge une contrainte d'actif existante<\/td><td>Quelle marge de man\u0153uvre existe-t-elle pendant la p\u00e9riode concern\u00e9e ?<\/td><\/tr><tr><td>Ajouts futurs de charge<\/td><td>Prot\u00e8ge le projet contre une base d'imposition obsol\u00e8te<\/td><td>Les chargeurs, les \u00e9quipements de production ou l'agrandissement des b\u00e2timents vont-ils modifier le profil de charge ?<\/td><\/tr><\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-afca38f6 elementor-tablet-align-center elementor-align-center auto-cta elementor-widget elementor-widget-button\" data-id=\"afca38f6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"#elementor-action%3Aaction%3Dpopup%3Aopen%26settings%3DeyJpZCI6Ijk0OCIsInRvZ2dsZSI6ZmFsc2V9\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Review My BESS Connection and Product Scope<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-282a7b64 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"282a7b64\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Convertir les donn\u00e9es d'exploitation du site en kW, kVA et consommation d'\u00e9nergie<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-edce837f auto-p elementor-widget elementor-widget-heading\" data-id=\"edce837f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Le profil de charge permet d'aborder trois questions techniques distinctes. Obligatoire <strong>kW<\/strong> d\u00e9crit la puissance active. Obligatoire <strong>kVA<\/strong> d\u00e9crit l'enveloppe de puissance apparente qui inclut la puissance r\u00e9active. Requis <strong>kWh<\/strong> d\u00e9crit la consommation d'\u00e9nergie au cours d'un \u00e9v\u00e9nement ou d'un calendrier d\u00e9fini. Le fait de distinguer ces mesures \u00e9vite qu'une proposition ne repose sur une seule valeur catalogue lorsque le fonctionnement du site d\u00e9pend de plusieurs variables \u00e9lectriques.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-bd3539b9 auto-p elementor-widget elementor-widget-heading\" data-id=\"bd3539b9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Pour une analyse pr\u00e9liminaire, la puissance active requise peut \u00eatre repr\u00e9sent\u00e9e par la puissance mesur\u00e9e sur site au-del\u00e0 de l'objectif convenu pour le PCC. L'\u00e9nergie de l'\u00e9v\u00e9nement correspond \u00e0 l'aire sous la courbe de cette puissance requise en fonction du temps. La puissance apparente s'ensuit <strong>S\u00b2 = P\u00b2 + Q\u00b2<\/strong>, o\u00f9 S correspond \u00e0 kVA, P \u00e0 kW et Q \u00e0 kvar. La m\u00e9thode retenue pour le projet doit respecter les limites de comptage, la convention de signe, la logique de consigne et la priorit\u00e9 de commande approuv\u00e9es.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f986a4ba auto-p elementor-widget elementor-widget-heading\" data-id=\"f986a4ba\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Le dossier technique doit indiquer <strong>capacit\u00e9 nominale de la batterie<\/strong>, <strong>plage horaire de livraison disponible<\/strong> et <strong>\u00e9nergie CA livr\u00e9e<\/strong> sous forme de valeurs distinctes. Chaque valeur correspond \u00e0 une limite et \u00e0 une d\u00e9finition op\u00e9rationnelle diff\u00e9rentes. Le fait de les distinguer permet au ma\u00eetre d'ouvrage de comparer les propositions de mani\u00e8re \u00e9quitable et fournit au plan de r\u00e9ception une base pr\u00e9cise pour tout test de performance ult\u00e9rieur.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-dcd24cb8 auto-table elementor-widget elementor-widget-text-editor\" data-id=\"dcd24cb8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"cea-table-wrap\"><table><thead><tr><th>\u00c9v\u00e9nement op\u00e9rationnel<\/th><th>Informations n\u00e9cessaires au calcul<\/th><th>D\u00e9cision \u00e9clair\u00e9e<\/th><\/tr><\/thead><tbody><tr><td>Pic de r\u00e9gulation en fonction de la demande<\/td><td>Courbe de puissance du PCC (en kW), limite de puissance cible (en kW) et dur\u00e9e de l'\u00e9v\u00e9nement<\/td><td>Fonctionnement en puissance active du PCS et fen\u00eatre d'\u00e9nergie pr\u00e9liminaire<\/td><\/tr><tr><td>Rampe de d\u00e9marrage du moteur ou du processus<\/td><td>S\u00e9quence de d\u00e9marrage, \u00e9volution en kW\/kVA, facteur de puissance et fr\u00e9quence de r\u00e9p\u00e9tition<\/td><td>Marge de puissance apparente du PCS et strat\u00e9gie de mont\u00e9e en puissance<\/td><\/tr><tr><td>Prise en charge des charges critiques<\/td><td>Liste des charges essentielles, profil de puissance, dur\u00e9e requise et logique de r\u00e9tablissement<\/td><td>Fonction de secours, plage d'\u00e9nergie et champ d'application du transfert\/contr\u00f4le<\/td><\/tr><tr><td>Coordination des g\u00e9n\u00e9rateurs<\/td><td>Puissance nominale du g\u00e9n\u00e9rateur, charge minimale, logique de r\u00e9gulation et charge du site<\/td><td>Interfaces de commande et modes de fonctionnement homologu\u00e9s<\/td><\/tr><tr><td>Installation photovolta\u00efque existante sur le site<\/td><td>Puissance de l'onduleur photovolta\u00efque, emplacement du point de raccordement au r\u00e9seau (PCC) et logique de gestion des exportations<\/td><td>Emplacement des compteurs et s\u00e9quence de r\u00e9partition combin\u00e9e<\/td><\/tr><\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c1706d76 auto-p elementor-widget elementor-widget-heading\" data-id=\"c1706d76\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Il en r\u00e9sulte une sp\u00e9cification technique du projet plut\u00f4t qu'une simple estimation g\u00e9n\u00e9rique des besoins. Celle-ci doit pr\u00e9ciser la puissance CA requise, la plage de puissance apparente, la dur\u00e9e, les possibilit\u00e9s de recharge, la plage de facteur de puissance et la logique de commande. Les \u00e9quipes EPC peuvent utiliser <strong><a href=\"https:\/\/www.solidess.com\/fr\/les-epcs-evaluent-les-systemes-de-stockage-denergie\/\" target=\"_blank\" style=\"color:#61ce70\">Comment les EPC \u00e9valuent les syst\u00e8mes de stockage d'\u00e9nergie<\/a><\/strong> afin d'inscrire cette description de mission dans le cadre d'un examen plus large de la mise en \u0153uvre du projet.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-305fef7a auto-h2 elementor-widget elementor-widget-heading\" data-id=\"305fef7a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">V\u00e9rifier les contraintes relatives aux transformateurs, au PCC et \u00e0 la protection avant de proc\u00e9der au dimensionnement d\u00e9finitif<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b027ae9d auto-p elementor-widget elementor-widget-heading\" data-id=\"b027ae9d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Une batterie peut r\u00e9duire la puissance visible au point de raccordement (PCC) pendant certaines p\u00e9riodes, mais le raccordement du site reste soumis aux contraintes li\u00e9es au transformateur, \u00e0 l\u2019appareillage de commutation, aux dispositifs de protection et aux conditions du r\u00e9seau public. Une \u00e9tude compl\u00e8te doit donc examiner le sch\u00e9ma de raccordement du syst\u00e8me de stockage par batterie (BESS) ainsi que la capacit\u00e9 de la batterie. Cela rev\u00eat une importance particuli\u00e8re lorsque le projet vise \u00e0 g\u00e9rer une contrainte li\u00e9e au transformateur, \u00e0 respecter une limite d\u2019importation ou \u00e0 prendre en charge une charge industrielle variable.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-245ce783 auto-p elementor-widget elementor-widget-heading\" data-id=\"245ce783\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">La puissance nominale en kVA indiqu\u00e9e sur la plaque signal\u00e9tique du transformateur sert de r\u00e9f\u00e9rence. La charge par intervalles, les conditions de tension, l'imp\u00e9dance de la source (le cas \u00e9ch\u00e9ant) et les informations relatives \u00e0 la protection d\u00e9crivent le contexte d'exploitation du raccordement envisag\u00e9. Il convient d'examiner ces deux ensembles de donn\u00e9es avant de choisir le c\u00e2ble d'alimentation, le disjoncteur, le trac\u00e9 du c\u00e2ble et les limites de contr\u00f4le du syst\u00e8me de stockage d'\u00e9nergie par batterie (BESS).<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-891b67a9 auto-p elementor-widget elementor-widget-heading\" data-id=\"891b67a9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Le <strong><a href=\"https:\/\/www.solidess.com\/fr\/il-vaut-mieux-eviter-la-modernisation-du-transformateur\/\" target=\"_blank\" style=\"color:#61ce70\">Guide de planification de la modernisation des syst\u00e8mes BESS et des transformateurs<\/a><\/strong> fournit un cadre d\u00e9cisionnel en la mati\u00e8re. L'\u00e9tude sur site doit permettre de v\u00e9rifier la charge actuelle du transformateur, les conditions d'exploitation autoris\u00e9es du PCC, les caract\u00e9ristiques nominales des c\u00e2bles et des disjoncteurs, les hypoth\u00e8ses relatives aux niveaux de d\u00e9faut, la coordination des protections ainsi que l'identit\u00e9 du propri\u00e9taire de l'\u00e9quipement pour chaque interface en amont.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-87ad010b auto-image elementor-widget elementor-widget-image\" data-id=\"87ad010b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"864\" height=\"648\" src=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/Commercial-BESS-PCC-Data-Collection.png\" class=\"attachment-1536x1536 size-1536x1536 wp-image-4764\" alt=\"Syst\u00e8me de stockage d&#039;\u00e9nergie MegSolid MEGA \u00e0 c\u00f4t\u00e9 d&#039;un transformateur, d&#039;un tableau de distribution PCC et d&#039;un ing\u00e9nieur examinant le sch\u00e9ma unifilaire\" srcset=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/Commercial-BESS-PCC-Data-Collection.png 864w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/Commercial-BESS-PCC-Data-Collection-300x225.png 300w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/Commercial-BESS-PCC-Data-Collection-768x576.png 768w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/Commercial-BESS-PCC-Data-Collection-600x450.png 600w\" sizes=\"(max-width: 864px) 100vw, 864px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b95553dc auto-table elementor-widget elementor-widget-text-editor\" data-id=\"b95553dc\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"cea-table-wrap\"><table><thead><tr><th>Interface<\/th><th>\u00c9l\u00e9ments de preuve \u00e0 recueillir<\/th><th>D\u00e9cision relative au champ d'application approuv\u00e9e<\/th><\/tr><\/thead><tbody><tr><td>PCC et compteur de recettes<\/td><td>R\u00e9f\u00e9rence du sch\u00e9ma, disposition CT\/PT, sens de rotation du compteur et signal de commande<\/td><td>Limites de la zone d'intervention et points de mesure des performances<\/td><\/tr><tr><td>Transformateur<\/td><td>puissance nominale en kVA, rapport de tension, historique de charge, donn\u00e9es d'imp\u00e9dance (le cas \u00e9ch\u00e9ant) et limites de fonctionnement<\/td><td>Hauteur libre disponible et disposition des raccordements<\/td><\/tr><tr><td>Tableau \u00e9lectrique BT<\/td><td>Caract\u00e9ristiques des bus, espace r\u00e9serv\u00e9 aux c\u00e2bles d'alimentation, donn\u00e9es relatives aux disjoncteurs, trac\u00e9 des c\u00e2bles et restrictions d'acc\u00e8s<\/td><td>P\u00e9rim\u00e8tre des \u00e9quipements auxiliaires locaux<\/td><\/tr><tr><td>Syst\u00e8me de protection<\/td><td>Fonctions des relais, r\u00e9glages, \u00e9tude de coordination et interfaces de d\u00e9clenchement<\/td><td>Essais obligatoires relatifs \u00e0 l'ing\u00e9nierie de protection et \u00e0 la mise en service<\/td><\/tr><tr><td>Processus utilitaire<\/td><td>Fondements de la demande d'interconnexion, limites approuv\u00e9es et exigences en mati\u00e8re de t\u00e9moins<\/td><td>Autorisations, proc\u00e9dure d'acceptation et responsabilit\u00e9s<\/td><\/tr><\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8ebd0279 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"8ebd0279\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">D\u00e9finir les limites de contr\u00f4le, de comptage et de distribution<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-cea50888 auto-p elementor-widget elementor-widget-heading\" data-id=\"cea50888\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Les r\u00e9sultats commerciaux d\u00e9pendent de la mani\u00e8re dont le syst\u00e8me per\u00e7oit le site et de l'entit\u00e9 qui contr\u00f4le chaque mode de fonctionnement. Le syst\u00e8me de gestion de l'\u00e9nergie (EMS) peut utiliser un compteur PCC, un compteur de charge du site, un bar\u00e8me tarifaire, l'\u00e9tat du g\u00e9n\u00e9rateur ou une consigne d\u00e9finie par le propri\u00e9taire. Le syst\u00e8me de contr\u00f4le de puissance (PCS) re\u00e7oit des commandes de puissance active et r\u00e9active dans les limites de son enveloppe de fonctionnement disponible. Le BMS fournit les limites et l\u2019\u00e9tat de la batterie. Ces r\u00f4les doivent \u00eatre pr\u00e9cis\u00e9s dans une matrice de communication avant la mise en service.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-771e06cc elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"771e06cc\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">\ud83e\udde0 Identifier le responsable des commandes pour les modes de charge, de d\u00e9charge, de facteur de puissance et de fonctionnement d'urgence.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">\ud83d\udd04 Indiquez le capteur qui fournit chaque valeur de contr\u00f4le, son intervalle de mise \u00e0 jour et sa convention de signe.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">\ud83d\udce1 Cartographier les interfaces EMS, PCS, BMS, du contr\u00f4leur de groupe \u00e9lectrog\u00e8ne, du syst\u00e8me de gestion technique du b\u00e2timent et des r\u00e9seaux publics.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">\ud83e\uddfe D\u00e9finir les documents n\u00e9cessaires \u00e0 la mise en service, \u00e0 la r\u00e9ception et \u00e0 l'analyse ult\u00e9rieure des dysfonctionnements.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">\ud83c\udfd7\ufe0f Distinguer les \u00e9quipements BESS fournis des travaux de g\u00e9nie civil locaux, des travaux sur les transformateurs, des c\u00e2bles, des appareillages de commutation, de la coordination avec les services publics et du p\u00e9rim\u00e8tre d'installation.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-14c0f4fe auto-p elementor-widget elementor-widget-heading\" data-id=\"14c0f4fe\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">L'autorit\u00e9 de contr\u00f4le est souvent \u00e0 l'origine de modifications techniques apport\u00e9es \u00e0 un stade avanc\u00e9 du projet. Le <strong><a href=\"https:\/\/www.solidess.com\/fr\/pourquoi-lintegration-du-pcs-et-du-bms-echoue\/\" target=\"_blank\" style=\"color:#61ce70\">Guide d'int\u00e9gration du PCS et du BMS<\/a><\/strong> permet aux \u00e9quipes de v\u00e9rifier les limites, les chemins de commande et les signaux de retour. Pour l\u2019interface CA, le <strong><a href=\"https:\/\/www.solidess.com\/fr\/ingenierie-des-onduleurs-pcs\/\" target=\"_blank\" style=\"color:#61ce70\">Guide technique PCS<\/a><\/strong> permet de v\u00e9rifier la tension du r\u00e9seau, la fr\u00e9quence, la puissance en kW et en kVA, le facteur de puissance et les exigences de raccordement.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9fdb40ab auto-table elementor-widget elementor-widget-text-editor\" data-id=\"9fdb40ab\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"cea-table-wrap\"><table><thead><tr><th>Limite<\/th><th>Partie \u00e0 d\u00e9signer<\/th><th>Document attestant de la d\u00e9cision<\/th><\/tr><\/thead><tbody><tr><td>Ensemble fourni par BESS<\/td><td>Fournisseur et int\u00e9grateur de syst\u00e8mes<\/td><td>Fiche technique, sch\u00e9ma, liste des interfaces de communication et justificatifs d'usine sp\u00e9cifiques au mod\u00e8le<\/td><\/tr><tr><td>Raccordements et appareillages de commutation CA<\/td><td>Entreprise de services \u00e9nerg\u00e9tiques (EPC) et installateur \u00e9lectricien<\/td><td>Plan de c\u00e2blage, choix des disjoncteurs, conception des dispositifs de protection et rapports d'essais d'installation<\/td><\/tr><tr><td>Transformateur et interface avec le r\u00e9seau \u00e9lectrique<\/td><td>Propri\u00e9taire du site, fournisseur d'\u00e9nergie et EPC d\u00e9sign\u00e9<\/td><td>Autorisation de raccordement, caract\u00e9ristiques du transformateur et sch\u00e9ma unifilaire contr\u00f4l\u00e9<\/td><\/tr><tr><td>Interface existante pour installation photovolta\u00efque ou groupe \u00e9lectrog\u00e8ne<\/td><td>Entreprise sp\u00e9cialis\u00e9e dans la production locale d'\u00e9lectricit\u00e9 et l'int\u00e9gration de syst\u00e8mes de contr\u00f4le-commande<\/td><td>Matrice des modes de fonctionnement, correspondance des indicateurs et s\u00e9quence de commande homologu\u00e9e<\/td><\/tr><tr><td>Acceptation du site<\/td><td>Propri\u00e9taire, EPC et fournisseur<\/td><td>Plan de contr\u00f4le, p\u00e9rim\u00e8tre de mesure, proc\u00e9dure d'essai et proc\u00e8s-verbal de cl\u00f4ture sign\u00e9<\/td><\/tr><\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ad69a025 auto-p elementor-widget elementor-widget-heading\" data-id=\"ad69a025\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Lorsque le syst\u00e8me photovolta\u00efque fait partie int\u00e9grante du site, il convient de documenter la capacit\u00e9 de l'onduleur, le point de raccordement \u00e9lectrique et la logique de gestion des exportations. Le p\u00e9rim\u00e8tre du syst\u00e8me de stockage d'\u00e9nergie par batterie (BESS) de MegSolid peut s'aligner sur ces donn\u00e9es du site ; l'acquisition et l'installation locales du syst\u00e8me photovolta\u00efque restent toutefois une t\u00e2che \u00e0 la charge du site. Cela permet de garantir la clart\u00e9 de l'offre en ce qui concerne les \u00e9quipements fournis et la responsabilit\u00e9 de la livraison locale.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b01753c5 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"b01753c5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Utiliser les donn\u00e9es produit au niveau du mod\u00e8le une fois la fonction du site d\u00e9finie<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f2ad0134 auto-p elementor-widget elementor-widget-heading\" data-id=\"f2ad0134\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Use the approved site duty to shortlist actual equipment. For an integrated cabinet, ESSA0100B-0215 publishes 100kW AC and 215.04kWh nominal energy with air cooling. A 261.24kWh \/ 125kVA liquid-cooled route offers a different power and thermal boundary; a separate MEGA PCS route suits custom battery packages. Ask MegSolid to show how the selected model meets kW, kVA, usable-energy and environmental requirements, and identify the external connection work in the same offer.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-85f5e6f3 auto-table elementor-widget elementor-widget-text-editor\" data-id=\"85f5e6f3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"cea-table-wrap\"><table><thead><tr><th>Itin\u00e9raire MegSolid<\/th><th>Donn\u00e9es de mod\u00e8les publics v\u00e9rifi\u00e9es<\/th><th>Utilisation dans le cadre de l'examen des interconnexions<\/th><\/tr><\/thead><tbody><tr><td>Armoire d'ext\u00e9rieur ESSA0100B-0215<\/td><td>100 kW CA ; 215,04 kWh ; LFP ; refroidissement par air intelligent<\/td><td>V\u00e9rifier la conformit\u00e9 avec les contraintes d'implantation \u00e0 proximit\u00e9 de la plage de puissance active \u00e0 l'\u00e9chelle de l'armoire et consigner les d\u00e9tails du raccordement CA propos\u00e9<\/td><\/tr><tr><td>Meg-Solid Energon - 261 kWh<\/td><td>261,24 kWh ; 125 kVA ; 314 Ah LFP ; 1P260S ; refroidissement par liquide<\/td><td>Associez la puissance en kW et le facteur de puissance requis \u00e0 la charge en puissance apparente du projet<\/td><\/tr><tr><td>PMA080 \/ PMA0105 \/ PMA0125 PCS<\/td><td>Puissance nominale en courant alternatif : 80 \/ 105 \/ 125 kW ; puissance apparente maximale : 96 \/ 126 \/ 150 kVA ; THDi du courant du r\u00e9seau inf\u00e9rieur \u00e0 2%<\/td><td>V\u00e9rifier la s\u00e9lection des PCS modulaires en fonction de la tension du site, de la charge en kVA et de l'interface BMS\/EMS<\/td><\/tr><tr><td>MEGA0030TS\u2013MEGA0500TS PCS<\/td><td>Puissance nominale : 30 \u00e0 500 kW ; puissance apparente maximale : 33 \u00e0 550 kVA ; tension nominale alternative : 400 V ; taux de distorsion harmonique (THD) du courant du r\u00e9seau inf\u00e9rieur \u00e0 3%<\/td><td>Examiner les blocs de climatisation de plus grande taille, ainsi que le rapport de transformation du transformateur d'isolation s\u00e9lectionn\u00e9 et le trac\u00e9 de l'installation \u00e9lectrique sur site<\/td><\/tr><\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-afb981e3 auto-image elementor-widget elementor-widget-image\" data-id=\"afb981e3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"864\" height=\"648\" src=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/Commercial-BESS-Interconnection-Review.png\" class=\"attachment-1536x1536 size-1536x1536 wp-image-4765\" alt=\"Syst\u00e8me de stockage d&#039;\u00e9nergie modulaire MegSolid PMA install\u00e9 dans un rack de commande de 19 pouces lors d&#039;une revue des donn\u00e9es et des interfaces du mod\u00e8le d&#039;ing\u00e9nierie\" srcset=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/Commercial-BESS-Interconnection-Review.png 864w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/Commercial-BESS-Interconnection-Review-300x225.png 300w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/Commercial-BESS-Interconnection-Review-768x576.png 768w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/Commercial-BESS-Interconnection-Review-600x450.png 600w\" sizes=\"(max-width: 864px) 100vw, 864px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4754328f auto-p elementor-widget elementor-widget-heading\" data-id=\"4754328f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Le <strong><a href=\"https:\/\/www.solidess.com\/fr\/product\/systeme-de-stockage-denergie-en-armoire-exterieure\/\" target=\"_blank\" style=\"color:#61ce70\">Page consacr\u00e9e au syst\u00e8me de stockage d'\u00e9nergie en armoire ext\u00e9rieure<\/a><\/strong> fournit l'itin\u00e9raire de la plateforme ESSA. Le <strong><a href=\"https:\/\/www.solidess.com\/fr\/product\/stockage-denergie-solide-liquide-megasolide\/\" target=\"_blank\" style=\"color:#61ce70\">Page consacr\u00e9e au syst\u00e8me C&amp;I \u00e0 refroidissement par liquide de 261,24 kWh<\/a><\/strong> propose la solution avec armoire de 125 kVA, et la <strong><a href=\"https:\/\/www.solidess.com\/fr\/product\/systeme-de-conversion-denergie-megsolid\/\" target=\"_blank\" style=\"color:#61ce70\">Page PCS sur le stockage d'\u00e9nergie MEGA<\/a><\/strong> indique la plage de rendement du PCS en mode isol\u00e9. Pour le syst\u00e8me de 261,24 kWh, la valeur 90% publi\u00e9e correspond au rendement maximal du syst\u00e8me ; l\u2019exigence relative au rendement aller-retour du projet et le r\u00e9sultat de la validation sur site doivent s\u2019appuyer sur des bases clairement d\u00e9finies.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6e69152e auto-p elementor-widget elementor-widget-heading\" data-id=\"6e69152e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Les conditions thermiques m\u00e9ritent \u00e9galement d'\u00eatre examin\u00e9es en fonction du mod\u00e8le. Une armoire refroidie par air, une armoire refroidie par liquide et un syst\u00e8me conteneuris\u00e9 pr\u00e9sentent chacun des consid\u00e9rations diff\u00e9rentes en mati\u00e8re d'implantation, de maintenance et de conditions ambiantes. Le <strong><a href=\"https:\/\/www.solidess.com\/fr\/bess-a-refroidissement-par-liquide-ou-par-air\/\" target=\"_blank\" style=\"color:#61ce70\">Guide de s\u00e9lection des syst\u00e8mes BESS \u00e0 refroidissement liquide et \u00e0 refroidissement par air<\/a><\/strong> permet de d\u00e9finir ce choix d'\u00e9quipement en fonction de l'environnement d'installation r\u00e9el.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-41d2cfee auto-h2 elementor-widget elementor-widget-heading\" data-id=\"41d2cfee\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Constituez un dossier de donn\u00e9es qui \u00e9taye une proposition pr\u00eate \u00e0 \u00eatre soumise<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1bc270c3 auto-p elementor-widget elementor-widget-heading\" data-id=\"1bc270c3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Send MegSolid one pack: controlled SLD, representative interval kW\/kVA data, transformer and switchboard ratings, PCC target, required duration, power-factor duty, generation\/generator details, communications and site conditions. Request an exact product route, preliminary power\/energy boundary, supplied equipment and unresolved site-side work. Bring the response back to the appointed EPC and utility before model approval; the quotation should expose connection risks while there is still time to change the scope.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-55a91b12 elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"55a91b12\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Sch\u00e9ma unifilaire valid\u00e9 et emplacement propos\u00e9 pour le raccordement du syst\u00e8me de stockage d'\u00e9nergie par batterie (BESS).<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Donn\u00e9es repr\u00e9sentatives sur les intervalles de puissance en kW\/kVA et les r\u00e9sultats d'exploitation requis.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Limite PCC, tarif ou objectif de ma\u00eetrise de la demande, ainsi que toute exigence en mati\u00e8re de gestion des exportations.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Informations relatives aux transformateurs, aux tableaux \u00e9lectriques, aux disjoncteurs, au trac\u00e9 des c\u00e2bles et aux dispositifs de protection.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Puissance requise en kW, dur\u00e9e, plage de facteur de puissance, charge en puissance r\u00e9active et priorit\u00e9s de fonctionnement.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Informations existantes concernant les installations photovolta\u00efques, les groupes \u00e9lectrog\u00e8nes, les charges de process et les communications.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Environnement du chantier, contraintes d'acc\u00e8s, plan de pr\u00e9sence lors de la mise en service et format de r\u00e9ception.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e28839f7 auto-p elementor-widget elementor-widget-heading\" data-id=\"e28839f7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Les donn\u00e9es relatives \u00e0 l'usine et au site doivent respecter les m\u00eames hypoth\u00e8ses de projet. Les <strong><a href=\"https:\/\/www.solidess.com\/fr\/guide-dessai-de-reception-en-usine-de-bess\/\" target=\"_blank\" style=\"color:#61ce70\">Guide des essais de r\u00e9ception en usine BESS<\/a><\/strong> constitue un point de d\u00e9part utile pour d\u00e9finir les \u00e9tats des lieux avant l'exp\u00e9dition. Un plan de site permet ensuite de v\u00e9rifier le p\u00e9rim\u00e8tre \u00e9lectrique install\u00e9, la cartographie des compteurs, la s\u00e9quence de commande et la documentation n\u00e9cessaire \u00e0 la remise commerciale.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-25c508df elementor-tablet-align-center elementor-align-center auto-cta elementor-widget elementor-widget-button\" data-id=\"25c508df\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"#elementor-action%3Aaction%3Dpopup%3Aopen%26settings%3DeyJpZCI6Ijk0OCIsInRvZ2dsZSI6ZmFsc2V9\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Envoyer un sch\u00e9ma unifilaire et des donn\u00e9es d'intervalle pour examen<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-bee03d38 auto-faq e-flex e-con-boxed e-con e-child\" data-id=\"bee03d38\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-fbad97c0 elementor-widget elementor-widget-heading\" data-id=\"fbad97c0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">FAQ<\/h2>\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-10aceeda e-con-full e-flex e-con e-child\" data-id=\"10aceeda\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-20627234 elementor-widget elementor-widget-n-accordion\" data-id=\"20627234\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;default_state&quot;:&quot;all_collapsed&quot;,&quot;max_items_expended&quot;:&quot;one&quot;,&quot;n_accordion_animation_duration&quot;:{&quot;unit&quot;:&quot;ms&quot;,&quot;size&quot;:400,&quot;sizes&quot;:[]}}\" data-widget_type=\"nested-accordion.default\">\n\t\t\t\t\t\t\t<div class=\"e-n-accordion\" aria-label=\"Accord\u00e9on. Ouvrez les liens \u00e0 l&#039;aide de la touche Entr\u00e9e ou de la barre d&#039;espace, fermez-les avec la touche \u00c9chap et naviguez \u00e0 l&#039;aide des touches fl\u00e9ch\u00e9es.\">\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-5430\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"1\" tabindex=\"0\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-5430\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Que signifie \u00ab l'aptitude au raccordement \u00bb d'un syst\u00e8me commercial de stockage d'\u00e9nergie ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-5430\" class=\"elementor-element elementor-element-5a93f4ec e-con-full e-flex e-con e-child\" data-id=\"5a93f4ec\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-5430\" class=\"elementor-element elementor-element-ce8a766b e-con-full e-flex e-con e-child\" data-id=\"ce8a766b\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-747e760b elementor-widget elementor-widget-heading\" data-id=\"747e760b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Cela signifie que l'\u00e9quipe charg\u00e9e du projet dispose de suffisamment d'informations v\u00e9rifi\u00e9es sur le site pour d\u00e9finir comment un syst\u00e8me de stockage d'\u00e9nergie par batterie (BESS) se raccorde, mesure, contr\u00f4le et prouve son bon fonctionnement. Cette analyse rassemble les donn\u00e9es relatives au PCC, au transformateur, au tableau de distribution, au profil de charge, aux puissances requises en kW et en kVA, \u00e0 la dur\u00e9e, aux dispositifs de protection et aux communications. Cela permet de transformer une demande pr\u00e9liminaire en un cahier des charges que les ma\u00eetres d'\u0153uvre (EPC), les propri\u00e9taires et les fournisseurs peuvent \u00e9valuer sur la base des m\u00eames hypoth\u00e8ses.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-5431\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"2\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-5431\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Quelles donn\u00e9es de charge une usine doit-elle fournir pour le dimensionnement d'un syst\u00e8me de stockage d'\u00e9nergie par batterie (BESS) \u00e0 usage commercial ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-5431\" class=\"elementor-element elementor-element-8b858edf e-con-full e-flex e-con e-child\" data-id=\"8b858edf\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-5431\" class=\"elementor-element elementor-element-04028f3d e-con-full e-flex e-con e-child\" data-id=\"04028f3d\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c9e36703 elementor-widget elementor-widget-heading\" data-id=\"c9e36703\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Fournissez des donn\u00e9es repr\u00e9sentatives en kW et en kVA, ainsi que les p\u00e9riodes de pointe, la charge de base, les horaires de travail et les \u00e9v\u00e9nements de processus connus. Indiquez la limite cible de PCC ou l'objectif de r\u00e9gulation de la demande. Les enregistrements effectu\u00e9s \u00e0 un intervalle appropri\u00e9 permettent de d\u00e9terminer la dur\u00e9e des \u00e9v\u00e9nements et la courbe de charge, deux \u00e9l\u00e9ments essentiels pour d\u00e9finir les besoins pr\u00e9liminaires en puissance et en \u00e9nergie.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-5432\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"3\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-5432\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Pourquoi une proposition relative \u00e0 un syst\u00e8me de stockage d'\u00e9nergie par batterie (BESS) \u00e0 usage commercial et une \u00e9tude sur les transformateurs vont-elles de pair ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-5432\" class=\"elementor-element elementor-element-25774b77 e-con-full e-flex e-con e-child\" data-id=\"25774b77\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-5432\" class=\"elementor-element elementor-element-f29b73d0 e-con-full e-flex e-con e-child\" data-id=\"f29b73d0\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-715ace23 elementor-widget elementor-widget-heading\" data-id=\"715ace23\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Le syst\u00e8me BESS se raccorde au r\u00e9seau \u00e9lectrique du site ; par cons\u00e9quent, la puissance nominale du transformateur, l'historique de charge, la tension, la capacit\u00e9 du tableau \u00e9lectrique et le dispositif de protection ont une incidence sur le sch\u00e9ma de raccordement envisageable. Une batterie peut prendre en charge certains intervalles PCC, mais le projet doit n\u00e9anmoins s'appuyer sur une compr\u00e9hension pr\u00e9cise des limites des \u00e9quipements en amont, des travaux locaux relatifs au \u00ab balance-of-plant \u00bb (BOP) et des contraintes d'exploitation accept\u00e9es par le site et le fournisseur d'\u00e9lectricit\u00e9.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-5433\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"4\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-5433\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> En quoi les valeurs en kW, kVA et kWh influencent-elles le choix d'un syst\u00e8me de stockage d'\u00e9nergie \u00e0 usage professionnel ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-5433\" class=\"elementor-element elementor-element-9978bcc3 e-con-full e-flex e-con e-child\" data-id=\"9978bcc3\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-5433\" class=\"elementor-element elementor-element-29aae9df e-con-full e-flex e-con e-child\" data-id=\"29aae9df\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-24b4ece9 elementor-widget elementor-widget-heading\" data-id=\"24b4ece9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Le kW d\u00e9finit la puissance active fournie. Le kVA d\u00e9finit l'enveloppe de puissance apparente, qui inclut \u00e9galement la puissance r\u00e9active. Le kWh d\u00e9finit l'\u00e9nergie disponible sur une p\u00e9riode de fonctionnement donn\u00e9e. Une \u00e9quipe de projet doit fournir ces trois valeurs, ainsi que le facteur de puissance pr\u00e9vu et la dur\u00e9e, car chacune d'entre elles correspond \u00e0 un aspect diff\u00e9rent de la charge \u00e9lectrique.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-5434\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"5\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-5434\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Quel point le syst\u00e8me de mesure de la demande et du contr\u00f4le BESS doit-il utiliser ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-5434\" class=\"elementor-element elementor-element-2bbacd00 e-con-full e-flex e-con e-child\" data-id=\"2bbacd00\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-5434\" class=\"elementor-element elementor-element-6ae7e7aa e-con-full e-flex e-con e-child\" data-id=\"6ae7e7aa\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-15c626b1 elementor-widget elementor-widget-heading\" data-id=\"15c626b1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Utilisez le point de mesure correspondant \u00e0 l'objectif commercial et au contrat de contr\u00f4le, g\u00e9n\u00e9ralement la limite PCC ou celle du compteur de recettes. Le sch\u00e9ma unifilaire contr\u00f4l\u00e9 doit identifier le compteur exact, la configuration des transformateurs de courant (TC) et de tension (TP), la convention de signe et l'intervalle de mise \u00e0 jour des donn\u00e9es. Cela permet au prestataire de services \u00e9nerg\u00e9tiques (EMS), au prestataire de services d'efficacit\u00e9 \u00e9nerg\u00e9tique (EPC) et au propri\u00e9taire de se r\u00e9f\u00e9rer \u00e0 la m\u00eame valeur lors de l'\u00e9valuation des r\u00e9sultats du site.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-5435\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"6\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-5435\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Quelles sont les informations n\u00e9cessaires pour choisir la puissance en kVA d'un PCS ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-5435\" class=\"elementor-element elementor-element-fcbc4954 e-con-full e-flex e-con e-child\" data-id=\"fcbc4954\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-5435\" class=\"elementor-element elementor-element-72552e0c e-con-full e-flex e-con e-child\" data-id=\"72552e0c\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-2c329881 elementor-widget elementor-widget-heading\" data-id=\"2c329881\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Indiquez la puissance active requise en kW, la plage de facteur de puissance pr\u00e9vue, le type de fonctionnement (puissance r\u00e9active ou soutien de tension), la tension du r\u00e9seau, la fr\u00e9quence, la rampe de charge et toute priorit\u00e9 entre la puissance active et la puissance r\u00e9active. L'\u00e9quipe de projet pourra alors comparer ces conditions de fonctionnement \u00e0 la capacit\u00e9 de puissance apparente du PCS s\u00e9lectionn\u00e9 et valider le choix du transformateur, de l'appareillage de commutation et du sch\u00e9ma de protection pour ce point de fonctionnement.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-5436\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"7\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-5436\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Comment faut-il prendre en compte les installations photovolta\u00efques ou un groupe \u00e9lectrog\u00e8ne dans l'\u00e9tude de raccordement d'un syst\u00e8me de stockage d'\u00e9nergie par batterie (BESS) \u00e0 usage commercial ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-5436\" class=\"elementor-element elementor-element-240aeaa1 e-con-full e-flex e-con e-child\" data-id=\"240aeaa1\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-5436\" class=\"elementor-element elementor-element-439c079f e-con-full e-flex e-con e-child\" data-id=\"439c079f\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-748bca6c elementor-widget elementor-widget-heading\" data-id=\"748bca6c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Indiquez chaque \u00e9quipement sur le sch\u00e9ma unifilaire et pr\u00e9cisez son point de raccordement, sa puissance nominale, son mode de commande, la source du compteur et sa priorit\u00e9 de fonctionnement. La conception du syst\u00e8me de stockage d'\u00e9nergie par batterie (BESS) tient alors compte \u00e0 la fois de la s\u00e9quence de mise en service du site et de la limite PCC applicable. Les partenaires EPC locaux d\u00e9finissent g\u00e9n\u00e9ralement l'approvisionnement en panneaux photovolta\u00efques, leur installation et la coordination avec le r\u00e9seau public dans le cadre du p\u00e9rim\u00e8tre des travaux sur site.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-5437\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"8\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-5437\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Quels sont les \u00e9l\u00e9ments de communication \u00e0 prendre en compte avant la mise en service d'un syst\u00e8me de stockage d'\u00e9nergie par batterie (BESS) \u00e0 usage commercial ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-5437\" class=\"elementor-element elementor-element-fcd1ab9c e-con-full e-flex e-con e-child\" data-id=\"fcd1ab9c\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-5437\" class=\"elementor-element elementor-element-44c325b7 e-con-full e-flex e-con e-child\" data-id=\"44c325b7\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-cd83e85f elementor-widget elementor-widget-heading\" data-id=\"cd83e85f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Le projet doit recenser le syst\u00e8me de gestion environnementale (EMS), le syst\u00e8me de contr\u00f4le de puissance (PCS), le syst\u00e8me de gestion des b\u00e2timents (BMS), le compteur de site, le contr\u00f4leur de groupe \u00e9lectrog\u00e8ne ainsi que toute interface avec le syst\u00e8me de gestion des b\u00e2timents ou le r\u00e9seau de distribution. Il convient de d\u00e9finir le protocole, l'\u00e9metteur de la commande, le sens du signal, l'intervalle de rafra\u00eechissement, l'autorit\u00e9 de consigne et l'enregistrement des donn\u00e9es. Cela permet d'\u00e9viter toute ambigu\u00eft\u00e9 quant aux responsabilit\u00e9s de contr\u00f4le lors de la mise en service et de constituer une trace \u00e9crite en vue d'un examen ult\u00e9rieur de l'exploitation.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-5438\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"9\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-5438\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Dans quels cas une \u00e9quipe de chantier doit-elle opter pour une solution de stockage d'\u00e9nergie par batterie (BESS) \u00e0 refroidissement par air ou par liquide ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-5438\" class=\"elementor-element elementor-element-6615b145 e-con-full e-flex e-con e-child\" data-id=\"6615b145\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-5438\" class=\"elementor-element elementor-element-ea19852f e-con-full e-flex e-con e-child\" data-id=\"ea19852f\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-74fa0bb4 elementor-widget elementor-widget-heading\" data-id=\"74fa0bb4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Ce choix doit \u00eatre effectu\u00e9 apr\u00e8s avoir pris connaissance de la puissance et de la taxe sur l'\u00e9nergie, des conditions ambiantes, des conditions d'acc\u00e8s, du plan de maintenance et de l'encombrement sur site. La documentation relative au mod\u00e8le s\u00e9lectionn\u00e9 doit ensuite confirmer son mode de refroidissement, ses conditions de fonctionnement et les exigences d'installation applicables. Le refroidissement fait partie int\u00e9grante de l'examen de la configuration et doit rester en ad\u00e9quation avec le mod\u00e8le r\u00e9el et l'environnement du projet.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-5439\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"10\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-5439\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Quels sont les \u00e9l\u00e9ments qui justifient la mise en service des syst\u00e8mes de stockage d'\u00e9nergie par batterie (BESS) \u00e0 des fins commerciales ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-5439\" class=\"elementor-element elementor-element-73d2ec23 e-con-full e-flex e-con e-child\" data-id=\"73d2ec23\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-5439\" class=\"elementor-element elementor-element-799d8c6f e-con-full e-flex e-con e-child\" data-id=\"799d8c6f\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-2372a09d elementor-widget elementor-widget-heading\" data-id=\"2372a09d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Un dossier de remise complet comprend g\u00e9n\u00e9ralement le sch\u00e9ma unifilaire approuv\u00e9, la fiche technique du mod\u00e8le s\u00e9lectionn\u00e9, les registres relatifs aux protections et aux compteurs, le sch\u00e9ma de communication, la proc\u00e9dure de mise en service, les r\u00e9sultats bruts des essais, les journaux de contr\u00f4le, les \u00e9carts constat\u00e9s et le proc\u00e8s-verbal de r\u00e9ception sign\u00e9. Les crit\u00e8res pr\u00e9cis de v\u00e9rification et de r\u00e9ception figurent dans les documents du projet, offrant ainsi \u00e0 toutes les parties une base tra\u00e7able pour l'installation achev\u00e9e.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-54310\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"11\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-54310\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> \u00c0 quoi un site commercial am\u00e9ricain doit-il se pr\u00e9parer en vue d'un examen de raccordement d'un syst\u00e8me de stockage d'\u00e9nergie par batterie (BESS) ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-54310\" class=\"elementor-element elementor-element-233ad347 e-con-full e-flex e-con e-child\" data-id=\"233ad347\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-54310\" class=\"elementor-element elementor-element-9faebb54 e-con-full e-flex e-con e-child\" data-id=\"9faebb54\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-1744c733 elementor-widget elementor-widget-heading\" data-id=\"1744c733\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Pr\u00e9parez le sch\u00e9ma \u00e9lectrique unifilaire du site, le relev\u00e9 des charges par intervalle, les informations relatives au PCC ou au compteur du fournisseur d\u2019\u00e9lectricit\u00e9, les donn\u00e9es concernant les transformateurs et les appareillages de commutation, les exigences du fournisseur d\u2019\u00e9lectricit\u00e9 local ainsi que l\u2019objectif d\u2019exploitation du projet. Pr\u00e9cisez la tension, la fr\u00e9quence, la puissance requise en kW et en kVA, la dur\u00e9e et le facteur de puissance. Le prestataire EPC d\u00e9sign\u00e9 et le fournisseur d\u2019\u00e9lectricit\u00e9 pourront alors confirmer les proc\u00e9dures locales applicables en mati\u00e8re de raccordement et d\u2019obtention des autorisations pour le site.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-54311\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"12\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-54311\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Quels documents un site industriel sud-africain doit-il fournir avant un examen de la port\u00e9e du projet BESS ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-54311\" class=\"elementor-element elementor-element-f2545054 e-con-full e-flex e-con e-child\" data-id=\"f2545054\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-54311\" class=\"elementor-element elementor-element-0b6586e8 e-con-full e-flex e-con e-child\" data-id=\"0b6586e8\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-46e0a5bc elementor-widget elementor-widget-heading\" data-id=\"46e0a5bc\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Veuillez fournir des donn\u00e9es repr\u00e9sentatives sur la charge de l\u2019installation, le sch\u00e9ma de raccordement au r\u00e9seau, les caract\u00e9ristiques du transformateur, les informations relatives \u00e0 la demande maximale, le mode de fonctionnement souhait\u00e9 ainsi que toutes les donn\u00e9es relatives aux g\u00e9n\u00e9rateurs ou aux interfaces photovolta\u00efques. Pr\u00e9cisez \u00e9galement les valeurs de r\u00e9f\u00e9rence locales en mati\u00e8re de tension et de fr\u00e9quence, les conditions ambiantes du site, l\u2019objectif de r\u00e9gulation du PCC et les exigences actuelles du r\u00e9seau de distribution. Ces informations permettront \u00e0 l\u2019\u00e9quipe charg\u00e9e du projet de r\u00e9aliser une analyse technique cibl\u00e9e adapt\u00e9e aux besoins r\u00e9els de l\u2019installation industrielle.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-54312\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"13\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-54312\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Quels sont les \u00e9l\u00e9ments n\u00e9cessaires \u00e0 l'\u00e9valuation d'un projet de raccordement d'un syst\u00e8me de stockage d'\u00e9nergie par batterie (BESS) \u00e0 des fins commerciales au Nigeria ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-54312\" class=\"elementor-element elementor-element-f8294976 e-con-full e-flex e-con e-child\" data-id=\"f8294976\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-54312\" class=\"elementor-element elementor-element-8d7af79a e-con-full e-flex e-con e-child\" data-id=\"8d7af79a\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-1d21ce28 elementor-widget elementor-widget-heading\" data-id=\"1d21ce28\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Fournissez le relev\u00e9 de charge du site, le sch\u00e9ma unifilaire contr\u00f4l\u00e9, les d\u00e9tails relatifs \u00e0 l'alimentation entrante, les informations concernant le transformateur et le tableau de distribution, les donn\u00e9es relatives au g\u00e9n\u00e9rateur le cas \u00e9ch\u00e9ant, les priorit\u00e9s de charge critiques et les heures de fonctionnement requises. Pr\u00e9cisez la puissance requise en kW et en kVA, la dur\u00e9e, l'objectif de contr\u00f4le et les conditions d'installation locales. L'EPC et l'autorit\u00e9 locale comp\u00e9tente en mati\u00e8re d'\u00e9lectricit\u00e9 pourront alors harmoniser le plan de raccordement d\u00e9taill\u00e9 avec les autorisations de projet pertinentes.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-54313\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"14\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-54313\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Comment d\u00e9terminer la taille d'un syst\u00e8me de stockage d'\u00e9nergie \u00e0 usage professionnel \u00e0 partir des donn\u00e9es du site ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-54313\" class=\"elementor-element elementor-element-35b765f1 e-con-full e-flex e-con e-child\" data-id=\"35b765f1\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-54313\" class=\"elementor-element elementor-element-4a439c72 e-con-full e-flex e-con e-child\" data-id=\"4a439c72\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-b7e65ab7 elementor-widget elementor-widget-heading\" data-id=\"b7e65ab7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Commencez par d\u00e9finir les limites contr\u00f4l\u00e9es du PCC et les donn\u00e9es repr\u00e9sentatives de la charge par intervalle. D\u00e9finissez l'\u00e9cart de puissance active, les besoins en puissance apparente, la dur\u00e9e de l'\u00e9v\u00e9nement, les opportunit\u00e9s de recharge, la plage de facteur de puissance et les modes de fonctionnement. Examinez simultan\u00e9ment les interfaces relatives aux transformateurs, aux appareillages de commutation, aux protections et aux commandes. Ces donn\u00e9es permettent d'\u00e9tablir un profil de fonctionnement pr\u00e9liminaire du syst\u00e8me de stockage d'\u00e9nergie par batterie (BESS) avant que le mod\u00e8le s\u00e9lectionn\u00e9 et les documents du projet ne confirment la configuration finale.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-54314\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"15\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-54314\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Quels sont les crit\u00e8res qui permettent de d\u00e9terminer si une solution BESS commerciale de 100 kW ou de 125 kVA est adapt\u00e9e \u00e0 un site ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-54314\" class=\"elementor-element elementor-element-531dfe08 e-con-full e-flex e-con e-child\" data-id=\"531dfe08\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-54314\" class=\"elementor-element elementor-element-96eab11c e-con-full e-flex e-con e-child\" data-id=\"96eab11c\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-58845c32 elementor-widget elementor-widget-heading\" data-id=\"58845c32\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Comparez la charge mesur\u00e9e sur site avec la puissance active requise, la puissance apparente, le facteur de puissance, la dur\u00e9e de l'\u00e9v\u00e9nement, le calendrier de charge, la limite PCC et la tension de raccordement. Une valeur de 100 kW et une valeur de 125 kVA correspondent \u00e0 des grandeurs \u00e9lectriques diff\u00e9rentes. La fiche technique du mod\u00e8le s\u00e9lectionn\u00e9, l\u2019enveloppe PCS disponible et le trac\u00e9 de raccordement du site d\u00e9terminent si la configuration propos\u00e9e est adapt\u00e9e \u00e0 la charge.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-54315\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"16\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-54315\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Quels documents dois-je fournir pour une \u00e9valuation du raccordement d'un syst\u00e8me commercial de stockage d'\u00e9nergie ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-54315\" class=\"elementor-element elementor-element-3136acc9 e-con-full e-flex e-con e-child\" data-id=\"3136acc9\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-54315\" class=\"elementor-element elementor-element-794d94c2 e-con-full e-flex e-con e-child\" data-id=\"794d94c2\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a13ce0d3 elementor-widget elementor-widget-heading\" data-id=\"a13ce0d3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Veuillez nous transmettre le sch\u00e9ma unifilaire r\u00e9gul\u00e9, les donn\u00e9es repr\u00e9sentatives en kW et kVA par intervalle, la limite PCC, les informations relatives aux transformateurs et aux appareillages de commutation, la puissance souhait\u00e9e en kW et la dur\u00e9e, le facteur de puissance attendu, les donn\u00e9es relatives \u00e0 la production existante ou aux g\u00e9n\u00e9rateurs, les besoins en mati\u00e8re de communication, l'environnement du site et le format de r\u00e9ception. Ce dossier fournit \u00e0 l'\u00e9quipe d'ing\u00e9nieurs une base concr\u00e8te pour \u00e9laborer un cahier des charges commercial sp\u00e9cifique au projet concernant le syst\u00e8me de stockage d'\u00e9nergie par batterie (BESS).<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>A commercial energy storage system can arrive before the site is ready to use it. Review PCC, transformer, switchboard and load limits, then request a MegSolid battery\/PCS route with a clear supplied scope and unresolved site-side work.<\/p>","protected":false},"author":4,"featured_media":4763,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"_joinchat":[],"footnotes":""},"categories":[1,710],"tags":[334,335,318,339,36,336,338,337],"class_list":["post-4766","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-bess","category-energy-storage-markets-policy","tag-bess-interconnection","tag-commercial-bess-sizing","tag-commercial-energy-storage-system","tag-epc-engineering","tag-MegSolid","tag-pcc-data","tag-pcs-kva","tag-transformer-capacity"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/posts\/4766","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/comments?post=4766"}],"version-history":[{"count":11,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/posts\/4766\/revisions"}],"predecessor-version":[{"id":6308,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/posts\/4766\/revisions\/6308"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/media\/4763"}],"wp:attachment":[{"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/media?parent=4766"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/categories?post=4766"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/tags?post=4766"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}