{"id":4766,"date":"2026-08-14T09:16:48","date_gmt":"2026-08-14T01:16:48","guid":{"rendered":"https:\/\/www.solidess.com\/?p=4766"},"modified":"2026-11-25T18:29:25","modified_gmt":"2026-11-25T10:29:25","slug":"aptitude-au-raccordement-dun-systeme-de-stockage-denergie-commercial","status":"publish","type":"post","link":"https:\/\/www.solidess.com\/fr\/commercial-energy-storage-system-interconnection-readiness\/","title":{"rendered":"Votre syst\u00e8me de stockage commercial est-il pr\u00eat pour le raccordement au r\u00e9seau ?"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"4766\" class=\"elementor elementor-4766\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-bf4793c e-con-full auto-article-root e-flex e-con e-parent\" data-id=\"bf4793c\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-cbcdc4f8 auto-p elementor-widget elementor-widget-heading\" data-id=\"cbcdc4f8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Commander une batterie ne d\u00e9bloque pas un raccordement. Si le transformateur est satur\u00e9, si la limite au point de couplage commun (PCC) est mal d\u00e9finie ou si le tableau ne peut recevoir le d\u00e9part \u00e9lectrique, le syst\u00e8me de stockage d\u2019\u00e9nergie peut arriver avant que le site soit pr\u00eat \u00e0 l\u2019utiliser. Partez des relev\u00e9s de charge par intervalle, du sch\u00e9ma unifilaire, des limites des \u00e9quipements en amont et de l\u2019objectif d\u2019exploitation. MegSolid peut s\u2019appuyer sur ces besoins pour \u00e9tudier la configuration batterie et PCS avant que la commande ne fixe une configuration inadapt\u00e9e.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ccce4c3a auto-image elementor-widget elementor-widget-image\" data-id=\"ccce4c3a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"768\" height=\"768\" src=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/Commercial-Energy-Storage-System-Interconnection-Readiness.png\" class=\"attachment-1536x1536 size-1536x1536 wp-image-4763\" alt=\"MegSolid MEGA PCS, syst\u00e8me de stockage d&#039;\u00e9nergie par batterie (BESS) ESSC en conteneur, rack modulaire PMA PCS, transformateur et PCC : aper\u00e7u de l&#039;interconnexion d&#039;un syst\u00e8me BESS commercial\" srcset=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/Commercial-Energy-Storage-System-Interconnection-Readiness.png 768w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/Commercial-Energy-Storage-System-Interconnection-Readiness-300x300.png 300w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/Commercial-Energy-Storage-System-Interconnection-Readiness-150x150.png 150w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/Commercial-Energy-Storage-System-Interconnection-Readiness-600x600.png 600w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/Commercial-Energy-Storage-System-Interconnection-Readiness-100x100.png 100w\" sizes=\"(max-width: 768px) 100vw, 768px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-297715a9 auto-p elementor-widget elementor-widget-heading\" data-id=\"297715a9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Pour le propri\u00e9taire, cette \u00e9tude prot\u00e8ge les conditions d\u2019exploitation promises. Pour l\u2019entreprise EPC, elle identifie les travaux de raccordement du d\u00e9part, de protection et de commande \u00e0 chiffrer. Pour les achats, elle permet de comparer trois devis fond\u00e9s sur des catalogues \u00e0 partir d\u2019un m\u00eame besoin du site. Utilisez les donn\u00e9es suivantes pour obtenir cette clart\u00e9 avant l\u2019attribution du march\u00e9.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f9e465ba auto-table elementor-widget elementor-widget-text-editor\" data-id=\"f9e465ba\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"cea-table-wrap\"><table><thead><tr><th>D\u00e9cision \u00e0 prendre<\/th><th>Justificatifs relatifs au site requis<\/th><th>R\u00e9duction des risques li\u00e9s au projet<\/th><\/tr><\/thead><tbody><tr><td>R\u00e9gime de charge et de d\u00e9charge requis<\/td><td>Profil de charge par intervalle, puissance appel\u00e9e cible et plage de fonctionnement<\/td><td>Une plage de puissance et de dur\u00e9e qui refl\u00e8te les conditions r\u00e9elles d'utilisation<\/td><\/tr><tr><td>P\u00e9rim\u00e8tre d'exploitation du PCC<\/td><td>Sch\u00e9ma unifilaire \u00e0 r\u00e9vision ma\u00eetris\u00e9e, emplacement du compteur de facturation et limites d\u2019injection et de soutirage<\/td><td>Un champ d'application align\u00e9 sur le point \u00e9lectrique qui r\u00e9git l'installation<\/td><\/tr><tr><td>Configuration du transformateur et de l\u2019appareillage \u00e9lectrique<\/td><td>Donn\u00e9es figurant sur la plaque signal\u00e9tique, capacit\u00e9 disponible, niveau de tension et informations relatives \u00e0 la protection<\/td><td>Identification pr\u00e9coce des contraintes en amont et des \u00e9quipements et travaux locaux annexes<\/td><\/tr><tr><td>Capacit\u00e9s du PCS<\/td><td>Puissance requise (kW, kVA), plage de facteur de puissance et priorit\u00e9 de commande<\/td><td>Plage de fonctionnement r\u00e9aliste c\u00f4t\u00e9 courant alternatif<\/td><\/tr><tr><td>Justificatifs de r\u00e9ception et de remise de l\u2019installation<\/td><td>Crit\u00e8res d'acceptation, propri\u00e9t\u00e9 des donn\u00e9es et registres de mise en service<\/td><td>Un parcours tra\u00e7able, de la proposition \u00e0 la r\u00e9ception du chantier<\/td><\/tr><\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-30e9cc25 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"30e9cc25\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">D\u00e9finir l'enveloppe d'interconnexion et l'enregistrement de charge<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-cd579519 auto-p elementor-widget elementor-widget-heading\" data-id=\"cd579519\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">L\u2019\u00e9tude du raccordement commence par le p\u00e9rim\u00e8tre \u00e9lectrique qui compte pour le projet commercial. Pour de nombreux projets derri\u00e8re le compteur, il s\u2019agit du point de couplage commun ou du p\u00e9rim\u00e8tre du compteur de facturation du site. Le sch\u00e9ma unifilaire approuv\u00e9 devrait montrer l\u2019interface avec le r\u00e9seau public, le transformateur, le tableau principal, le point de raccordement du BESS, les jeux de barres des charges principales et toute production d\u00e9j\u00e0 raccord\u00e9e. Ce sch\u00e9ma fournit \u00e0 toutes les parties une r\u00e9f\u00e9rence unique pour le flux de puissance pr\u00e9vu.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-cc44e084 auto-p elementor-widget elementor-widget-heading\" data-id=\"cc44e084\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Les relev\u00e9s de charge par intervalle indiquent quand le site a besoin du BESS. Une facture mensuelle donne un aper\u00e7u, tandis que des relev\u00e9s \u00e0 intervalles de 15 minutes ou moins r\u00e9v\u00e8lent le profil des pointes, la charge de base, les rampes de puissance, les changements d\u2019\u00e9quipe et les \u00e9v\u00e9nements r\u00e9currents. Cette distinction compte si le site pr\u00e9voit de ma\u00eetriser la puissance appel\u00e9e, d\u2019assurer une alimentation de secours, de coordonner un groupe \u00e9lectrog\u00e8ne ou de programmer la recharge. Le <strong><a href=\"https:\/\/www.solidess.com\/fr\/achat-de-stockage-denergie-commercial\/\" target=\"_blank\" style=\"color:#61ce70\">guide d\u2019achat de syst\u00e8mes de stockage d\u2019\u00e9nergie \u00e0 usage commercial<\/a><\/strong> explique en quoi ces donn\u00e9es op\u00e9rationnelles permettent une comparaison rigoureuse des fournisseurs.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-651b559e auto-p elementor-widget elementor-widget-heading\" data-id=\"651b559e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Les relev\u00e9s \u00e9nerg\u00e9tiques mensuels r\u00e9sument la consommation. Les relev\u00e9s par intervalle r\u00e9v\u00e8lent les courts \u00e9v\u00e9nements de puissance active en kW et de puissance apparente en kVA qui d\u00e9terminent le fonctionnement du stockage commercial. Un site \u00e0 consommation mensuelle mod\u00e9r\u00e9e peut tout de m\u00eame pr\u00e9senter des intervalles r\u00e9p\u00e9t\u00e9s de forte puissance appel\u00e9e lors d\u2019une s\u00e9quence de production, d\u2019une p\u00e9riode de recharge ou d\u2019un proc\u00e9d\u00e9 entra\u00een\u00e9 par un moteur. Le dimensionnement doit donc pr\u00e9ciser l\u2019\u00e9v\u00e9nement que le BESS doit traiter, plut\u00f4t que de prendre la consommation annuelle comme exigence d\u2019exploitation.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-90714aaa auto-h3 elementor-widget elementor-widget-heading\" data-id=\"90714aaa\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Donn\u00e9es minimales relatives au site pour une premi\u00e8re \u00e9tude technique<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7dcab163 elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"7dcab163\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">\ud83d\udcc8 Relev\u00e9s de puissance en kW et en kVA par intervalle, couvrant des jours d\u2019exploitation repr\u00e9sentatifs, les variations saisonni\u00e8res et les pointes connues.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">\ud83d\udccd Sch\u00e9ma unifilaire \u00e0 jour indiquant le PCC, le compteur de facturation, le transformateur et le point de raccordement pr\u00e9vu du BESS.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">\u26a1 Plaque signal\u00e9tique du transformateur, tensions primaire et secondaire, historique de la charge et espace disponible dans le tableau \u00e9lectrique.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">\ud83e\udded Limites de soutirage et d\u2019injection, p\u00e9riodes tarifaires, objectif de ma\u00eetrise de la puissance appel\u00e9e et modes de fonctionnement requis.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">\ud83c\udfed Principales charges li\u00e9es aux moteurs, aux variateurs, au soudage, \u00e0 la recharge, au CVC, au photovolta\u00efque ou au groupe \u00e9lectrog\u00e8ne qui provoquent des \u00e9chelons de charge ou cr\u00e9ent un besoin en puissance r\u00e9active.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">\ud83d\udee0\ufe0f R\u00e9glages des protections, configuration du comptage, architecture des communications et exigences de r\u00e9ception du ma\u00eetre d\u2019ouvrage.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-94b7c423 auto-table elementor-widget elementor-widget-text-editor\" data-id=\"94b7c423\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"cea-table-wrap\"><table><thead><tr><th>Champ de donn\u00e9es<\/th><th>Pourquoi cela modifie-t-il le champ d'application du BESS ?<\/th><th>Question d'examen pratique<\/th><\/tr><\/thead><tbody><tr><td>Pointe de puissance en kW sur l\u2019intervalle<\/td><td>D\u00e9finit l'\u00e9cart de puissance active que le syst\u00e8me de stockage d'\u00e9nergie par batterie (BESS) pourrait devoir combler<\/td><td>Quelles situations de charge entra\u00eenent les frais de puissance appel\u00e9e ?<\/td><\/tr><tr><td>kVA par intervalle et facteur de puissance<\/td><td>Pr\u00e9cise le besoin de puissance apparente vu par le PCS et les \u00e9quipements \u00e9lectriques en amont<\/td><td>La puissance r\u00e9active consomme-t-elle une partie de l'enveloppe PCS disponible ?<\/td><\/tr><tr><td>Limite cible du PCC<\/td><td>Fixe le seuil de pilotage \u00e0 partir de la mesure au PCC<\/td><td>Quelle valeur du compteur d\u00e9clenche la commande de charge ou de d\u00e9charge ?<\/td><\/tr><tr><td>Dur\u00e9e de la situation de charge<\/td><td>D\u00e9termine le besoin \u00e9nerg\u00e9tique pr\u00e9liminaire<\/td><td>Combien de temps dure chaque pic ou chaque \u00e9v\u00e9nement de charge critique ?<\/td><\/tr><tr><td>Charge du transformateur<\/td><td>Indique si le BESS doit aider \u00e0 g\u00e9rer une contrainte d\u2019un \u00e9quipement existant<\/td><td>Quelle marge de man\u0153uvre existe-t-elle pendant la p\u00e9riode concern\u00e9e ?<\/td><\/tr><tr><td>Ajouts futurs de charge<\/td><td>\u00c9vite de dimensionner le projet sur des besoins d\u2019exploitation devenus obsol\u00e8tes<\/td><td>Les chargeurs, les \u00e9quipements de production ou l'agrandissement des b\u00e2timents vont-ils modifier le profil de charge ?<\/td><\/tr><\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-afca38f6 elementor-tablet-align-center elementor-align-center auto-cta elementor-widget elementor-widget-button\" data-id=\"afca38f6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"#elementor-action%3Aaction%3Dpopup%3Aopen%26settings%3DeyJpZCI6Ijk0OCIsInRvZ2dsZSI6ZmFsc2V9\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Examiner mon raccordement BESS et le p\u00e9rim\u00e8tre produit<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-282a7b64 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"282a7b64\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">D\u00e9duisez les besoins en kW, kVA et kWh \u00e0 partir des \u00e9v\u00e9nements du site<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-edce837f auto-p elementor-widget elementor-widget-heading\" data-id=\"edce837f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Le profil de charge permet d\u2019aborder trois questions techniques distinctes. La valeur requise en <strong>kW<\/strong> indique la puissance active. La valeur requise en <strong>kVA<\/strong> d\u00e9finit la plage de puissance apparente, qui tient compte de la puissance r\u00e9active. La valeur requise en <strong>kWh<\/strong> indique l\u2019\u00e9nergie n\u00e9cessaire sur la dur\u00e9e d\u2019un \u00e9v\u00e9nement ou d\u2019un programme d\u00e9fini. Distinguer ces grandeurs \u00e9vite de fonder une offre sur une seule valeur de catalogue quand plusieurs param\u00e8tres \u00e9lectriques d\u00e9terminent le fonctionnement du site.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-bd3539b9 auto-p elementor-widget elementor-widget-heading\" data-id=\"bd3539b9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Pour une premi\u00e8re \u00e9tude, le besoin de puissance active peut \u00eatre repr\u00e9sent\u00e9 par la puissance du site mesur\u00e9e au-del\u00e0 de la cible convenue au PCC. L\u2019\u00e9nergie de l\u2019\u00e9v\u00e9nement correspond \u00e0 l\u2019aire sous la courbe de cette puissance requise en fonction du temps. La puissance apparente suit la relation <strong>S\u00b2 = P\u00b2 + Q\u00b2<\/strong>, o\u00f9 S s\u2019exprime en kVA, P en kW et Q en kvar. La m\u00e9thode d\u00e9finitive devrait utiliser le p\u00e9rim\u00e8tre de mesure, la convention de signe, la logique de consigne et la priorit\u00e9 de commande approuv\u00e9s.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f986a4ba auto-p elementor-widget elementor-widget-heading\" data-id=\"f986a4ba\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Le dossier technique devrait indiquer <strong>l\u2019\u00e9nergie nominale de la batterie<\/strong>, <strong>la plage d\u2019\u00e9nergie utilisable pour le pilotage<\/strong> et <strong>l\u2019\u00e9nergie fournie c\u00f4t\u00e9 courant alternatif<\/strong> comme des valeurs distinctes. Chacune correspond \u00e0 un p\u00e9rim\u00e8tre et \u00e0 des conditions d\u2019exploitation propres. Cette distinction permet au ma\u00eetre d\u2019ouvrage de comparer les offres \u00e9quitablement et donne au plan de r\u00e9ception une base pr\u00e9cise pour les essais de performance ult\u00e9rieurs.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-dcd24cb8 auto-table elementor-widget elementor-widget-text-editor\" data-id=\"dcd24cb8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"cea-table-wrap\"><table><thead><tr><th>\u00c9v\u00e9nement op\u00e9rationnel<\/th><th>Informations n\u00e9cessaires au calcul<\/th><th>D\u00e9cision \u00e9clair\u00e9e<\/th><\/tr><\/thead><tbody><tr><td>Pointe de puissance \u00e0 ma\u00eetriser<\/td><td>Courbe de puissance du PCC (en kW), limite de puissance cible (en kW) et dur\u00e9e de l'\u00e9v\u00e9nement<\/td><td>Besoin de puissance active du PCS et plage d\u2019\u00e9nergie pr\u00e9liminaire<\/td><\/tr><tr><td>Mont\u00e9e en charge d\u2019un moteur ou d\u2019un proc\u00e9d\u00e9<\/td><td>S\u00e9quence de d\u00e9marrage, \u00e9volution en kW\/kVA, facteur de puissance et fr\u00e9quence de r\u00e9p\u00e9tition<\/td><td>Marge de puissance apparente du PCS et strat\u00e9gie de mont\u00e9e en puissance<\/td><\/tr><tr><td>Prise en charge des charges critiques<\/td><td>Liste des charges essentielles, profil de puissance, dur\u00e9e requise et logique de r\u00e9tablissement<\/td><td>Besoins de secours, plage d\u2019\u00e9nergie et p\u00e9rim\u00e8tre du transfert et de la commande<\/td><\/tr><tr><td>Coordination des g\u00e9n\u00e9rateurs<\/td><td>Puissance nominale du g\u00e9n\u00e9rateur, charge minimale, logique de r\u00e9gulation et charge du site<\/td><td>Interfaces de commande et modes de fonctionnement approuv\u00e9s<\/td><\/tr><tr><td>Installation photovolta\u00efque existante sur le site<\/td><td>Puissance de l\u2019onduleur photovolta\u00efque, emplacement du PCC et logique de limitation de l\u2019injection<\/td><td>Emplacement des compteurs et s\u00e9quence de pilotage combin\u00e9<\/td><\/tr><\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c1706d76 auto-p elementor-widget elementor-widget-heading\" data-id=\"c1706d76\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">On obtient ainsi une description du fonctionnement requis pour le projet, au-del\u00e0 d\u2019une estimation g\u00e9n\u00e9rique de dimensionnement. Elle devrait pr\u00e9ciser la puissance requise c\u00f4t\u00e9 courant alternatif, la plage de puissance apparente, la dur\u00e9e, les possibilit\u00e9s de recharge, la plage de facteur de puissance et la logique de commande. Les \u00e9quipes EPC peuvent consulter le <strong><a href=\"https:\/\/www.solidess.com\/fr\/les-epcs-evaluent-les-systemes-de-stockage-denergie\/\" target=\"_blank\" style=\"color:#61ce70\">guide sur l\u2019\u00e9valuation des syst\u00e8mes de stockage d\u2019\u00e9nergie par les entreprises EPC<\/a><\/strong> pour inscrire ce profil d\u2019exploitation dans une \u00e9tude plus large de la r\u00e9alisation du projet.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-305fef7a auto-h2 elementor-widget elementor-widget-heading\" data-id=\"305fef7a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">V\u00e9rifier les contraintes relatives aux transformateurs, au PCC et \u00e0 la protection avant de proc\u00e9der au dimensionnement d\u00e9finitif<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b027ae9d auto-p elementor-widget elementor-widget-heading\" data-id=\"b027ae9d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Une batterie peut r\u00e9duire la puissance mesur\u00e9e au PCC pendant certains intervalles. Le raccordement du site reste toutefois r\u00e9gi par son transformateur, son appareillage, ses protections et les conditions du gestionnaire de r\u00e9seau. Une \u00e9tude compl\u00e8te examine le chemin de raccordement du BESS en m\u00eame temps que la capacit\u00e9 de la batterie. C\u2019est particuli\u00e8rement important si le projet vise \u00e0 g\u00e9rer une contrainte du transformateur, \u00e0 respecter une limite de soutirage ou \u00e0 soutenir une charge industrielle changeante.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-245ce783 auto-p elementor-widget elementor-widget-heading\" data-id=\"245ce783\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">La puissance en kVA inscrite sur la plaque du transformateur sert de r\u00e9f\u00e9rence nominale. La charge par intervalle, les conditions de tension, l\u2019imp\u00e9dance de la source lorsqu\u2019elle est connue et les informations sur les protections d\u00e9crivent les conditions d\u2019exploitation du raccordement envisag\u00e9. Examinez les deux s\u00e9ries de donn\u00e9es avant de choisir le d\u00e9part \u00e9lectrique, le disjoncteur, le cheminement des c\u00e2bles et le p\u00e9rim\u00e8tre de commande du BESS.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-891b67a9 auto-p elementor-widget elementor-widget-heading\" data-id=\"891b67a9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default translation-block\">Le <strong><a href=\"https:\/\/www.solidess.com\/fr\/il-vaut-mieux-eviter-la-modernisation-du-transformateur\/\" target=\"_blank\" style=\"color:#61ce70\">guide de planification des BESS et du renforcement des transformateurs<\/a><\/strong> propose un cadre de d\u00e9cision compl\u00e9mentaire. L\u2019\u00e9tude du site devrait confirmer la charge actuelle du transformateur, les conditions d\u2019exploitation autoris\u00e9es au PCC, les caract\u00e9ristiques nominales des c\u00e2bles et des disjoncteurs, les hypoth\u00e8ses de niveau de court-circuit, la coordination des protections et le propri\u00e9taire des \u00e9quipements pour chaque interface en amont.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-87ad010b auto-image elementor-widget elementor-widget-image\" data-id=\"87ad010b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"864\" height=\"648\" src=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/Commercial-BESS-PCC-Data-Collection.png\" class=\"attachment-1536x1536 size-1536x1536 wp-image-4764\" alt=\"Syst\u00e8me de stockage d&#039;\u00e9nergie MegSolid MEGA \u00e0 c\u00f4t\u00e9 d&#039;un transformateur, d&#039;un tableau de distribution PCC et d&#039;un ing\u00e9nieur examinant le sch\u00e9ma unifilaire\" srcset=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/Commercial-BESS-PCC-Data-Collection.png 864w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/Commercial-BESS-PCC-Data-Collection-300x225.png 300w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/Commercial-BESS-PCC-Data-Collection-768x576.png 768w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/Commercial-BESS-PCC-Data-Collection-600x450.png 600w\" sizes=\"(max-width: 864px) 100vw, 864px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b95553dc auto-table elementor-widget elementor-widget-text-editor\" data-id=\"b95553dc\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"cea-table-wrap\"><table><thead><tr><th>Interface<\/th><th>\u00c9l\u00e9ments de preuve \u00e0 recueillir<\/th><th>D\u00e9cision de p\u00e9rim\u00e8tre \u00e9tay\u00e9e<\/th><\/tr><\/thead><tbody><tr><td>PCC et compteur de facturation<\/td><td>R\u00e9f\u00e9rence du sch\u00e9ma, configuration des transformateurs de courant et de tension (CT\/PT), sens du comptage et signal de commande<\/td><td>P\u00e9rim\u00e8tre du pilotage et point de mesure des performances<\/td><\/tr><tr><td>Transformateur<\/td><td>puissance nominale en kVA, rapport de tension, historique de charge, donn\u00e9es d'imp\u00e9dance (le cas \u00e9ch\u00e9ant) et limites de fonctionnement<\/td><td>Marge de puissance disponible et configuration du raccordement<\/td><\/tr><tr><td>Tableau \u00e9lectrique BT<\/td><td>Caract\u00e9ristiques nominales du jeu de barres, place disponible pour un d\u00e9part, donn\u00e9es du disjoncteur, cheminement des c\u00e2bles et restrictions d\u2019acc\u00e8s<\/td><td>P\u00e9rim\u00e8tre des \u00e9quipements et travaux locaux annexes<\/td><\/tr><tr><td>Syst\u00e8me de protection<\/td><td>Fonctions des relais, r\u00e9glages, \u00e9tude de coordination et interfaces de d\u00e9clenchement<\/td><td>\u00c9tude des protections et essais de mise en service \u00e0 pr\u00e9voir<\/td><\/tr><tr><td>Proc\u00e9dure du gestionnaire de r\u00e9seau<\/td><td>Base de la demande de raccordement, limites approuv\u00e9es et exigences de pr\u00e9sence aux essais<\/td><td>Autorisations, proc\u00e9dure d'acceptation et responsabilit\u00e9s<\/td><\/tr><\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8ebd0279 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"8ebd0279\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">D\u00e9finissez les p\u00e9rim\u00e8tres de commande, de comptage et de fourniture<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-cea50888 auto-p elementor-widget elementor-widget-heading\" data-id=\"cea50888\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Les r\u00e9sultats commerciaux d\u00e9pendent de la mani\u00e8re dont le syst\u00e8me per\u00e7oit le site et de l'entit\u00e9 qui contr\u00f4le chaque mode de fonctionnement. Le syst\u00e8me de gestion de l'\u00e9nergie (EMS) peut utiliser un compteur PCC, un compteur de charge du site, un bar\u00e8me tarifaire, l'\u00e9tat du g\u00e9n\u00e9rateur ou une consigne d\u00e9finie par le propri\u00e9taire. Le syst\u00e8me de conversion de puissance (PCS) re\u00e7oit des commandes de puissance active et r\u00e9active dans les limites de son enveloppe de fonctionnement disponible. Le BMS fournit les limites et l\u2019\u00e9tat de la batterie. Ces r\u00f4les doivent \u00eatre pr\u00e9cis\u00e9s dans une matrice de communication avant la mise en service.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-771e06cc elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"771e06cc\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">\ud83e\udde0 Identifier le responsable des commandes pour les modes de charge, de d\u00e9charge, de facteur de puissance et de fonctionnement d'urgence.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">\ud83d\udd04 Indiquez le compteur qui fournit chaque valeur utilis\u00e9e pour la commande, son intervalle d\u2019actualisation et sa convention de signe.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">\ud83d\udce1 Cartographier les interfaces EMS, PCS, BMS, du contr\u00f4leur de groupe \u00e9lectrog\u00e8ne, du syst\u00e8me de gestion technique du b\u00e2timent et des r\u00e9seaux publics.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">\ud83e\uddfe D\u00e9finir les documents n\u00e9cessaires \u00e0 la mise en service, \u00e0 la r\u00e9ception et \u00e0 l'analyse ult\u00e9rieure des dysfonctionnements.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">\ud83c\udfd7\ufe0f Distinguez les \u00e9quipements BESS fournis du g\u00e9nie civil sur site, des travaux sur le transformateur, des c\u00e2bles, de l\u2019appareillage, de la coordination avec le gestionnaire de r\u00e9seau et des travaux d\u2019installation.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-14c0f4fe auto-p elementor-widget elementor-widget-heading\" data-id=\"14c0f4fe\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">La r\u00e9partition de l\u2019autorit\u00e9 de commande est une source fr\u00e9quente de changements techniques tardifs. Le <strong><a href=\"https:\/\/www.solidess.com\/fr\/pourquoi-lintegration-du-pcs-et-du-bms-echoue\/\" target=\"_blank\" style=\"color:#61ce70\">Guide d'int\u00e9gration du PCS et du BMS<\/a><\/strong> aide \u00e0 examiner les limites, les circuits de commande et les signaux de retour. Pour l\u2019interface c\u00f4t\u00e9 courant alternatif, le <strong><a href=\"https:\/\/www.solidess.com\/fr\/ingenierie-des-onduleurs-pcs\/\" target=\"_blank\" style=\"color:#61ce70\">guide technique du PCS<\/a><\/strong> permet de v\u00e9rifier la tension du r\u00e9seau, la fr\u00e9quence, la puissance en kW et en kVA, le facteur de puissance et les exigences de raccordement.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9fdb40ab auto-table elementor-widget elementor-widget-text-editor\" data-id=\"9fdb40ab\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"cea-table-wrap\"><table><thead><tr><th>Limite<\/th><th>Partie \u00e0 d\u00e9signer<\/th><th>Document attestant de la d\u00e9cision<\/th><\/tr><\/thead><tbody><tr><td>Lot BESS fourni<\/td><td>Fournisseur et int\u00e9grateur de syst\u00e8mes<\/td><td>Fiche technique, sch\u00e9ma, liste des interfaces de communication et justificatifs d'usine sp\u00e9cifiques au mod\u00e8le<\/td><\/tr><tr><td>Raccordements et appareillages de commutation CA<\/td><td>Entreprise charg\u00e9e de l\u2019ing\u00e9nierie, des achats et de la construction (EPC) et installateur \u00e9lectricien<\/td><td>Plan de c\u00e2blage, choix des disjoncteurs, conception des dispositifs de protection et rapports d'essais d'installation<\/td><\/tr><tr><td>Transformateur et interface avec le r\u00e9seau \u00e9lectrique<\/td><td>Propri\u00e9taire du site, gestionnaire de r\u00e9seau et entreprise EPC d\u00e9sign\u00e9e<\/td><td>Autorisation de raccordement, donn\u00e9es du transformateur et sch\u00e9ma unifilaire \u00e0 r\u00e9vision ma\u00eetris\u00e9e<\/td><\/tr><tr><td>Interface avec le photovolta\u00efque ou le groupe \u00e9lectrog\u00e8ne existant<\/td><td>Prestataire charg\u00e9 des installations de production locale et int\u00e9grateur des syst\u00e8mes de commande<\/td><td>Matrice des modes de fonctionnement, correspondance des compteurs et s\u00e9quence de commande approuv\u00e9e<\/td><\/tr><tr><td>R\u00e9ception sur site<\/td><td>Propri\u00e9taire, EPC et fournisseur<\/td><td>Plan de pr\u00e9sence aux essais, p\u00e9rim\u00e8tre de mesure, proc\u00e9dure d\u2019essai et proc\u00e8s-verbal de cl\u00f4ture sign\u00e9<\/td><\/tr><\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ad69a025 auto-p elementor-widget elementor-widget-heading\" data-id=\"ad69a025\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Si le site comporte du photovolta\u00efque, documentez la puissance de ses onduleurs, le point de raccordement \u00e9lectrique et la logique de limitation de l\u2019injection. La fourniture BESS de MegSolid peut \u00eatre coordonn\u00e9e avec ces donn\u00e9es. L\u2019achat et l\u2019installation locale du photovolta\u00efque restent \u00e0 la charge du projet c\u00f4t\u00e9 site. Cela clarifie quels \u00e9quipements sont fournis et qui assume la r\u00e9alisation locale.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b01753c5 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"b01753c5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Utilisez les donn\u00e9es du mod\u00e8le une fois les besoins d\u2019exploitation du site d\u00e9finis<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f2ad0134 auto-p elementor-widget elementor-widget-heading\" data-id=\"f2ad0134\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Pr\u00e9s\u00e9lectionnez les \u00e9quipements sur la base des besoins approuv\u00e9s du site. L\u2019armoire int\u00e9gr\u00e9e ESSA0100B-0215 affiche 100 kW c\u00f4t\u00e9 courant alternatif, une \u00e9nergie nominale de 215,04 kWh et un refroidissement par air. Une option \u00e0 refroidissement liquide de 261,24 kWh \/ 125 kVA offre d\u2019autres caract\u00e9ristiques \u00e9lectriques et thermiques. Une configuration \u00e0 PCS MEGA s\u00e9par\u00e9 convient aux ensembles de batteries sur mesure. Demandez \u00e0 MegSolid de montrer comment le mod\u00e8le retenu r\u00e9pond aux besoins en kW, en kVA, en \u00e9nergie utilisable et aux exigences environnementales, et de pr\u00e9ciser dans la m\u00eame offre les travaux de raccordement externe.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-85f5e6f3 auto-table elementor-widget elementor-widget-text-editor\" data-id=\"85f5e6f3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"cea-table-wrap\"><table><thead><tr><th>Option MegSolid<\/th><th>Donn\u00e9es publiques v\u00e9rifi\u00e9es du mod\u00e8le<\/th><th>Utilisation dans le cadre de l'examen des interconnexions<\/th><\/tr><\/thead><tbody><tr><td>Armoire d'ext\u00e9rieur ESSA0100B-0215<\/td><td>100 kW CA ; 215,04 kWh ; LFP ; refroidissement par air intelligent<\/td><td>V\u00e9rifiez les besoins d\u2019un site dont la puissance active est proche de la plage de l\u2019armoire et consignez les d\u00e9tails du raccordement propos\u00e9 c\u00f4t\u00e9 courant alternatif.<\/td><\/tr><tr><td>Meg-Solid Energon - 261 kWh<\/td><td>261,24 kWh ; 125 kVA ; 314 Ah LFP ; 1P260S ; refroidissement par liquide<\/td><td>Mettez en relation la puissance requise en kW et le facteur de puissance avec le besoin de puissance apparente du projet.<\/td><\/tr><tr><td>PMA080 \/ PMA0105 \/ PMA0125 PCS<\/td><td>Puissance nominale en courant alternatif : 80 \/ 105 \/ 125 kW ; puissance apparente maximale : 96 \/ 126 \/ 150 kVA ; THDi du courant du r\u00e9seau inf\u00e9rieur \u00e0 2%<\/td><td>V\u00e9rifiez le choix du PCS modulaire au regard de la tension du site, du besoin en kVA et de l\u2019interface BMS\/EMS.<\/td><\/tr><tr><td>MEGA0030TS\u2013MEGA0500TS PCS<\/td><td>Puissance nominale : 30 \u00e0 500 kW ; puissance apparente maximale : 33 \u00e0 550 kVA ; tension nominale alternative : 400 V ; taux de distorsion harmonique (THD) du courant du r\u00e9seau inf\u00e9rieur \u00e0 3%<\/td><td>\u00c9tudiez les ensembles de plus forte puissance c\u00f4t\u00e9 courant alternatif avec le rapport de transformation du transformateur d\u2019isolement retenu et le chemin de raccordement \u00e0 l\u2019appareillage du site.<\/td><\/tr><\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-afb981e3 auto-image elementor-widget elementor-widget-image\" data-id=\"afb981e3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"864\" height=\"648\" src=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/Commercial-BESS-Interconnection-Review.png\" class=\"attachment-1536x1536 size-1536x1536 wp-image-4765\" alt=\"Syst\u00e8me de stockage d&#039;\u00e9nergie modulaire MegSolid PMA install\u00e9 dans un rack de commande de 19 pouces lors d&#039;une revue des donn\u00e9es et des interfaces du mod\u00e8le d&#039;ing\u00e9nierie\" srcset=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/Commercial-BESS-Interconnection-Review.png 864w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/Commercial-BESS-Interconnection-Review-300x225.png 300w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/Commercial-BESS-Interconnection-Review-768x576.png 768w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/Commercial-BESS-Interconnection-Review-600x450.png 600w\" sizes=\"(max-width: 864px) 100vw, 864px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4754328f auto-p elementor-widget elementor-widget-heading\" data-id=\"4754328f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default translation-block\">Le <strong><a href=\"https:\/\/www.solidess.com\/fr\/product\/systeme-de-stockage-denergie-en-armoire-exterieure\/\" target=\"_blank\" style=\"color:#61ce70\">contenu de la page du syst\u00e8me de stockage d\u2019\u00e9nergie en armoire ext\u00e9rieure<\/a><\/strong> pr\u00e9sente la plateforme ESSA. La <strong><a href=\"https:\/\/www.solidess.com\/fr\/product\/stockage-denergie-solide-liquide-megasolide\/\" target=\"_blank\" style=\"color:#61ce70\">page du syst\u00e8me commercial et industriel de 261,24 kWh \u00e0 refroidissement liquide<\/a><\/strong> pr\u00e9sente l\u2019option d\u2019armoire de 125 kVA, et la <strong><a href=\"https:\/\/www.solidess.com\/fr\/product\/systeme-de-conversion-denergie-megsolid\/\" target=\"_blank\" style=\"color:#61ce70\">page des PCS MEGA pour le stockage d\u2019\u00e9nergie<\/a><\/strong> pr\u00e9sente la gamme de PCS \u00e0 isolation galvanique. Pour le syst\u00e8me de 261,24 kWh, la valeur publi\u00e9e de 90 % correspond au rendement maximal du syst\u00e8me. Une exigence de rendement sur le cycle complet et un r\u00e9sultat de r\u00e9ception sur site doivent chacun reposer sur une base de mesure pr\u00e9cis\u00e9e.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6e69152e auto-p elementor-widget elementor-widget-heading\" data-id=\"6e69152e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Les conditions thermiques m\u00e9ritent \u00e9galement d'\u00eatre examin\u00e9es en fonction du mod\u00e8le. Une armoire refroidie par air, une armoire refroidie par liquide et un syst\u00e8me conteneuris\u00e9 pr\u00e9sentent chacun des consid\u00e9rations diff\u00e9rentes en mati\u00e8re d'implantation, de maintenance et de conditions ambiantes. Le <strong><a href=\"https:\/\/www.solidess.com\/fr\/bess-a-refroidissement-par-liquide-ou-par-air\/\" target=\"_blank\" style=\"color:#61ce70\">Guide de s\u00e9lection des syst\u00e8mes BESS \u00e0 refroidissement liquide et \u00e0 refroidissement par air<\/a><\/strong> permet de d\u00e9finir ce choix d'\u00e9quipement en fonction de l'environnement d'installation r\u00e9el.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-41d2cfee auto-h2 elementor-widget elementor-widget-heading\" data-id=\"41d2cfee\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Constituez un dossier de donn\u00e9es qui \u00e9taye une proposition pr\u00eate \u00e0 \u00eatre soumise<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1bc270c3 auto-p elementor-widget elementor-widget-heading\" data-id=\"1bc270c3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Envoyez \u00e0 MegSolid un dossier unique contenant le sch\u00e9ma unifilaire \u00e0 r\u00e9vision ma\u00eetris\u00e9e, des relev\u00e9s repr\u00e9sentatifs en kW et en kVA par intervalle, les caract\u00e9ristiques nominales du transformateur et du tableau, la cible au PCC, la dur\u00e9e requise, les besoins en facteur de puissance, les donn\u00e9es de production ou du groupe \u00e9lectrog\u00e8ne, les communications et les conditions du site. Demandez une option de produit pr\u00e9cise, un p\u00e9rim\u00e8tre pr\u00e9liminaire de puissance et d\u2019\u00e9nergie, la liste des \u00e9quipements fournis et les travaux restant \u00e0 d\u00e9finir c\u00f4t\u00e9 site. Pr\u00e9sentez la r\u00e9ponse \u00e0 l\u2019entreprise EPC d\u00e9sign\u00e9e et au gestionnaire de r\u00e9seau avant d\u2019approuver le mod\u00e8le. Le devis devrait faire appara\u00eetre les risques de raccordement tant qu\u2019il est possible de modifier le p\u00e9rim\u00e8tre.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-55a91b12 elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"55a91b12\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Sch\u00e9ma unifilaire valid\u00e9 et emplacement propos\u00e9 pour le raccordement du syst\u00e8me de stockage d'\u00e9nergie par batterie (BESS).<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Donn\u00e9es repr\u00e9sentatives sur les intervalles de puissance en kW\/kVA et les r\u00e9sultats d'exploitation requis.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Limite au PCC, tarif ou objectif de ma\u00eetrise de la puissance appel\u00e9e, et exigences \u00e9ventuelles de limitation de l\u2019injection.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Informations relatives aux transformateurs, aux tableaux \u00e9lectriques, aux disjoncteurs, au trac\u00e9 des c\u00e2bles et aux dispositifs de protection.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Puissance requise en kW, dur\u00e9e, plage de facteur de puissance, charge en puissance r\u00e9active et priorit\u00e9s de fonctionnement.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Informations existantes concernant les installations photovolta\u00efques, les groupes \u00e9lectrog\u00e8nes, les charges de process et les communications.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Environnement du chantier, contraintes d'acc\u00e8s, plan de pr\u00e9sence lors de la mise en service et format de r\u00e9ception.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e28839f7 auto-p elementor-widget elementor-widget-heading\" data-id=\"e28839f7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Les justificatifs d\u2019usine et de site devraient reposer sur les m\u00eames hypoth\u00e8ses de projet. Le <strong><a href=\"https:\/\/www.solidess.com\/fr\/guide-dessai-de-reception-en-usine-de-bess\/\" target=\"_blank\" style=\"color:#61ce70\">Guide des essais de r\u00e9ception en usine BESS<\/a><\/strong> aide \u00e0 d\u00e9finir les relev\u00e9s \u00e0 consigner lors des essais en pr\u00e9sence de t\u00e9moins avant exp\u00e9dition. Un plan d\u2019essais sur site permet ensuite de v\u00e9rifier le p\u00e9rim\u00e8tre \u00e9lectrique install\u00e9, la correspondance des compteurs, la s\u00e9quence de commande et la documentation n\u00e9cessaire \u00e0 la remise contractuelle de l\u2019installation.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-25c508df elementor-tablet-align-center elementor-align-center auto-cta elementor-widget elementor-widget-button\" data-id=\"25c508df\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"#elementor-action%3Aaction%3Dpopup%3Aopen%26settings%3DeyJpZCI6Ijk0OCIsInRvZ2dsZSI6ZmFsc2V9\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Envoyer un sch\u00e9ma unifilaire et des donn\u00e9es d'intervalle pour examen<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-bee03d38 auto-faq e-flex e-con-boxed e-con e-child\" data-id=\"bee03d38\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-fbad97c0 elementor-widget elementor-widget-heading\" data-id=\"fbad97c0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">FAQ<\/h2>\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-10aceeda e-con-full e-flex e-con e-child\" data-id=\"10aceeda\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-20627234 elementor-widget elementor-widget-n-accordion\" data-id=\"20627234\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;default_state&quot;:&quot;all_collapsed&quot;,&quot;max_items_expended&quot;:&quot;one&quot;,&quot;n_accordion_animation_duration&quot;:{&quot;unit&quot;:&quot;ms&quot;,&quot;size&quot;:400,&quot;sizes&quot;:[]}}\" data-widget_type=\"nested-accordion.default\">\n\t\t\t\t\t\t\t<div class=\"e-n-accordion\" aria-label=\"Accord\u00e9on. Ouvrez les liens \u00e0 l&#039;aide de la touche Entr\u00e9e ou de la barre d&#039;espace, fermez-les avec la touche \u00c9chap et naviguez \u00e0 l&#039;aide des touches fl\u00e9ch\u00e9es.\">\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-5430\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"1\" tabindex=\"0\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-5430\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Que signifie \u00ab l'aptitude au raccordement \u00bb d'un syst\u00e8me commercial de stockage d'\u00e9nergie ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-5430\" class=\"elementor-element elementor-element-5a93f4ec e-con-full e-flex e-con e-child\" data-id=\"5a93f4ec\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-5430\" class=\"elementor-element elementor-element-ce8a766b e-con-full e-flex e-con e-child\" data-id=\"ce8a766b\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-747e760b elementor-widget elementor-widget-heading\" data-id=\"747e760b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Cela signifie que l\u2019\u00e9quipe dispose d\u2019informations de site \u00e0 r\u00e9vision ma\u00eetris\u00e9e suffisantes pour d\u00e9finir le raccordement du BESS, ses mesures, sa commande et la mani\u00e8re dont il d\u00e9montrera le fonctionnement requis. L\u2019\u00e9tude rassemble le PCC, le transformateur, le tableau de distribution, le profil de charge, les besoins en kW et en kVA, la dur\u00e9e, les protections et les communications. La demande initiale devient ainsi un p\u00e9rim\u00e8tre que les entreprises EPC, les propri\u00e9taires et les fournisseurs peuvent \u00e9valuer sur la base des m\u00eames hypoth\u00e8ses.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-5431\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"2\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-5431\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Quelles donn\u00e9es de charge une usine doit-elle fournir pour le dimensionnement d'un syst\u00e8me de stockage d'\u00e9nergie par batterie (BESS) \u00e0 usage commercial ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-5431\" class=\"elementor-element elementor-element-8b858edf e-con-full e-flex e-con e-child\" data-id=\"8b858edf\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-5431\" class=\"elementor-element elementor-element-04028f3d e-con-full e-flex e-con e-child\" data-id=\"04028f3d\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c9e36703 elementor-widget elementor-widget-heading\" data-id=\"c9e36703\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Fournissez des relev\u00e9s repr\u00e9sentatifs en kW et en kVA par intervalle, les p\u00e9riodes de pointe, la charge de base, les horaires des \u00e9quipes et les \u00e9v\u00e9nements connus du proc\u00e9d\u00e9. Indiquez la limite vis\u00e9e au PCC ou l\u2019objectif de ma\u00eetrise de la puissance appel\u00e9e. Des relev\u00e9s \u00e0 un intervalle appropri\u00e9 r\u00e9v\u00e8lent la dur\u00e9e des \u00e9v\u00e9nements et le profil de charge n\u00e9cessaires \u00e0 une premi\u00e8re estimation des besoins en puissance et en \u00e9nergie.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-5432\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"3\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-5432\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Pourquoi une proposition relative \u00e0 un syst\u00e8me de stockage d'\u00e9nergie par batterie (BESS) \u00e0 usage commercial et une \u00e9tude sur les transformateurs vont-elles de pair ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-5432\" class=\"elementor-element elementor-element-25774b77 e-con-full e-flex e-con e-child\" data-id=\"25774b77\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-5432\" class=\"elementor-element elementor-element-f29b73d0 e-con-full e-flex e-con e-child\" data-id=\"f29b73d0\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-715ace23 elementor-widget elementor-widget-heading\" data-id=\"715ace23\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Le BESS se raccorde au r\u00e9seau \u00e9lectrique du site. La puissance nominale du transformateur, son historique de charge, la tension, la capacit\u00e9 du tableau et la configuration des protections conditionnent les solutions de raccordement. Une batterie peut apporter un soutien lors de certains intervalles au PCC, mais le projet doit encore cerner les limites des \u00e9quipements en amont, les \u00e9quipements et travaux locaux annexes et le p\u00e9rim\u00e8tre d\u2019exploitation accept\u00e9 par le site et le gestionnaire de r\u00e9seau.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-5433\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"4\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-5433\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> En quoi les valeurs en kW, kVA et kWh influencent-elles le choix d'un syst\u00e8me de stockage d'\u00e9nergie \u00e0 usage professionnel ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-5433\" class=\"elementor-element elementor-element-9978bcc3 e-con-full e-flex e-con e-child\" data-id=\"9978bcc3\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-5433\" class=\"elementor-element elementor-element-29aae9df e-con-full e-flex e-con e-child\" data-id=\"29aae9df\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-24b4ece9 elementor-widget elementor-widget-heading\" data-id=\"24b4ece9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Le kW d\u00e9finit la puissance active fournie. Le kVA d\u00e9finit l'enveloppe de puissance apparente, qui inclut \u00e9galement la puissance r\u00e9active. Le kWh d\u00e9finit l'\u00e9nergie disponible sur une p\u00e9riode de fonctionnement donn\u00e9e. Une \u00e9quipe de projet doit fournir ces trois valeurs, ainsi que le facteur de puissance pr\u00e9vu et la dur\u00e9e, car chacune d'entre elles correspond \u00e0 un aspect diff\u00e9rent de la charge \u00e9lectrique.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-5434\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"5\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-5434\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> \u00c0 quel point mesurer la puissance appel\u00e9e que le BESS doit r\u00e9guler ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-5434\" class=\"elementor-element elementor-element-2bbacd00 e-con-full e-flex e-con e-child\" data-id=\"2bbacd00\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-5434\" class=\"elementor-element elementor-element-6ae7e7aa e-con-full e-flex e-con e-child\" data-id=\"6ae7e7aa\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-15c626b1 elementor-widget elementor-widget-heading\" data-id=\"15c626b1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Utilisez le point de mesure correspondant \u00e0 l\u2019objectif commercial et \u00e0 l\u2019accord de commande, g\u00e9n\u00e9ralement le PCC ou le p\u00e9rim\u00e8tre du compteur de facturation. Le sch\u00e9ma unifilaire \u00e0 r\u00e9vision ma\u00eetris\u00e9e devrait pr\u00e9ciser le compteur exact, la configuration des transformateurs de courant et de tension (CT\/PT), la convention de signe et l\u2019intervalle d\u2019actualisation. Le syst\u00e8me de gestion de l\u2019\u00e9nergie (EMS), l\u2019entreprise EPC et le propri\u00e9taire peuvent ainsi se r\u00e9f\u00e9rer \u00e0 la m\u00eame valeur pour \u00e9valuer le r\u00e9sultat sur site.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-5435\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"6\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-5435\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Quelles sont les informations n\u00e9cessaires pour choisir la puissance en kVA d'un PCS ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-5435\" class=\"elementor-element elementor-element-fcbc4954 e-con-full e-flex e-con e-child\" data-id=\"fcbc4954\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-5435\" class=\"elementor-element elementor-element-72552e0c e-con-full e-flex e-con e-child\" data-id=\"72552e0c\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-2c329881 elementor-widget elementor-widget-heading\" data-id=\"2c329881\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Indiquez la puissance active requise en kW, la plage de facteur de puissance pr\u00e9vue, le type de fonctionnement (puissance r\u00e9active ou soutien de tension), la tension du r\u00e9seau, la fr\u00e9quence, la rampe de charge et toute priorit\u00e9 entre la puissance active et la puissance r\u00e9active. L'\u00e9quipe de projet pourra alors comparer ces conditions de fonctionnement \u00e0 la capacit\u00e9 de puissance apparente du PCS s\u00e9lectionn\u00e9 et valider le choix du transformateur, de l'appareillage de commutation et du sch\u00e9ma de protection pour ce point de fonctionnement.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-5436\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"7\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-5436\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Comment faut-il prendre en compte les installations photovolta\u00efques ou un groupe \u00e9lectrog\u00e8ne dans l'\u00e9tude de raccordement d'un syst\u00e8me de stockage d'\u00e9nergie par batterie (BESS) \u00e0 usage commercial ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-5436\" class=\"elementor-element elementor-element-240aeaa1 e-con-full e-flex e-con e-child\" data-id=\"240aeaa1\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-5436\" class=\"elementor-element elementor-element-439c079f e-con-full e-flex e-con e-child\" data-id=\"439c079f\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-748bca6c elementor-widget elementor-widget-heading\" data-id=\"748bca6c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Indiquez chaque \u00e9quipement sur le sch\u00e9ma unifilaire et pr\u00e9cisez son point de raccordement, sa puissance de sortie nominale, son mode de commande, le compteur de r\u00e9f\u00e9rence et sa priorit\u00e9 d\u2019exploitation. La conception du BESS tient ainsi compte du pilotage coordonn\u00e9 des \u00e9quipements et de la limite applicable au PCC. Les partenaires EPC locaux d\u00e9finissent g\u00e9n\u00e9ralement l\u2019achat et l\u2019installation du photovolta\u00efque et la coordination avec le gestionnaire de r\u00e9seau dans le p\u00e9rim\u00e8tre des travaux c\u00f4t\u00e9 site.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-5437\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"8\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-5437\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Quels sont les \u00e9l\u00e9ments de communication \u00e0 prendre en compte avant la mise en service d'un syst\u00e8me de stockage d'\u00e9nergie par batterie (BESS) \u00e0 usage commercial ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-5437\" class=\"elementor-element elementor-element-fcd1ab9c e-con-full e-flex e-con e-child\" data-id=\"fcd1ab9c\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-5437\" class=\"elementor-element elementor-element-44c325b7 e-con-full e-flex e-con e-child\" data-id=\"44c325b7\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-cd83e85f elementor-widget elementor-widget-heading\" data-id=\"cd83e85f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Le projet devrait identifier le syst\u00e8me de gestion de l\u2019\u00e9nergie (EMS), le syst\u00e8me de conversion de puissance (PCS), le syst\u00e8me de gestion de la batterie (BMS), le compteur du site, le contr\u00f4leur du groupe \u00e9lectrog\u00e8ne et les interfaces \u00e9ventuelles avec la gestion technique du b\u00e2timent ou le gestionnaire de r\u00e9seau. Pr\u00e9cisez le protocole, le responsable de la commande, le sens du signal, l\u2019intervalle d\u2019actualisation, l\u2019autorit\u00e9 qui fixe la consigne et les donn\u00e9es \u00e0 enregistrer. Cela clarifie la responsabilit\u00e9 de commande lors de la mise en service et cr\u00e9e des traces pour les v\u00e9rifications ult\u00e9rieures.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-5438\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"9\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-5438\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Dans quels cas une \u00e9quipe de chantier doit-elle opter pour une solution de stockage d'\u00e9nergie par batterie (BESS) \u00e0 refroidissement par air ou par liquide ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-5438\" class=\"elementor-element elementor-element-6615b145 e-con-full e-flex e-con e-child\" data-id=\"6615b145\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-5438\" class=\"elementor-element elementor-element-ea19852f e-con-full e-flex e-con e-child\" data-id=\"ea19852f\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-74fa0bb4 elementor-widget elementor-widget-heading\" data-id=\"74fa0bb4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Faites ce choix apr\u00e8s avoir d\u00e9fini les besoins en puissance et en \u00e9nergie, les conditions ambiantes, l\u2019acc\u00e8s, le plan de maintenance et l\u2019emprise disponible. La documentation du mod\u00e8le retenu devrait confirmer le mode de refroidissement, les conditions d\u2019exploitation et les exigences d\u2019installation applicables. Le refroidissement est l\u2019un des \u00e9l\u00e9ments \u00e0 examiner pour choisir la configuration et doit rester adapt\u00e9 au mod\u00e8le et \u00e0 l\u2019environnement du projet.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-5439\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"10\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-5439\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Quels justificatifs faut-il fournir lors de la remise d\u2019un BESS commercial ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-5439\" class=\"elementor-element elementor-element-73d2ec23 e-con-full e-flex e-con e-child\" data-id=\"73d2ec23\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-5439\" class=\"elementor-element elementor-element-799d8c6f e-con-full e-flex e-con e-child\" data-id=\"799d8c6f\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-2372a09d elementor-widget elementor-widget-heading\" data-id=\"2372a09d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Le dossier de remise comprend g\u00e9n\u00e9ralement le sch\u00e9ma unifilaire approuv\u00e9, la fiche technique du mod\u00e8le retenu, les relev\u00e9s des protections et du comptage, le sch\u00e9ma des communications, la proc\u00e9dure de mise en service, les fichiers bruts des essais, les journaux de commande, les \u00e9carts et le proc\u00e8s-verbal de r\u00e9ception sign\u00e9. Les modalit\u00e9s pr\u00e9cises de pr\u00e9sence aux essais et les crit\u00e8res de r\u00e9ussite doivent figurer dans les documents du projet, afin que toutes les parties disposent d\u2019une r\u00e9f\u00e9rence tra\u00e7able pour l\u2019installation termin\u00e9e.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-54310\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"11\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-54310\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> \u00c0 quoi un site commercial am\u00e9ricain doit-il se pr\u00e9parer en vue d'un examen de raccordement d'un syst\u00e8me de stockage d'\u00e9nergie par batterie (BESS) ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-54310\" class=\"elementor-element elementor-element-233ad347 e-con-full e-flex e-con e-child\" data-id=\"233ad347\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-54310\" class=\"elementor-element elementor-element-9faebb54 e-con-full e-flex e-con e-child\" data-id=\"9faebb54\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-1744c733 elementor-widget elementor-widget-heading\" data-id=\"1744c733\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Pr\u00e9parez le sch\u00e9ma \u00e9lectrique unifilaire du site, les relev\u00e9s de charge par intervalle, les donn\u00e9es du PCC ou du compteur du gestionnaire de r\u00e9seau, les informations sur le transformateur et l\u2019appareillage, les exigences locales du gestionnaire de r\u00e9seau et l\u2019objectif d\u2019exploitation. Pr\u00e9cisez la tension, la fr\u00e9quence, les besoins en kW et en kVA, la dur\u00e9e et les exigences de facteur de puissance. L\u2019entreprise EPC d\u00e9sign\u00e9e et le gestionnaire de r\u00e9seau peuvent alors confirmer la proc\u00e9dure locale de raccordement et d\u2019autorisation applicable au site.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-54311\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"12\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-54311\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Quels documents un site industriel sud-africain doit-il fournir avant un examen de la port\u00e9e du projet BESS ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-54311\" class=\"elementor-element elementor-element-f2545054 e-con-full e-flex e-con e-child\" data-id=\"f2545054\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-54311\" class=\"elementor-element elementor-element-0b6586e8 e-con-full e-flex e-con e-child\" data-id=\"0b6586e8\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-46e0a5bc elementor-widget elementor-widget-heading\" data-id=\"46e0a5bc\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Fournissez des relev\u00e9s de charge repr\u00e9sentatifs, le sch\u00e9ma de raccordement au r\u00e9seau, les donn\u00e9es du transformateur, la puissance maximale appel\u00e9e, le mode de fonctionnement souhait\u00e9 et les donn\u00e9es d\u2019interface du groupe \u00e9lectrog\u00e8ne ou du photovolta\u00efque, le cas \u00e9ch\u00e9ant. Ajoutez les r\u00e9f\u00e9rences locales de tension et de fr\u00e9quence, les conditions ambiantes, la consigne au PCC et les exigences en vigueur du gestionnaire du r\u00e9seau de distribution. L\u2019\u00e9quipe pourra ainsi \u00e9tudier les besoins r\u00e9els de l\u2019installation industrielle.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-54312\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"13\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-54312\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Quels sont les \u00e9l\u00e9ments n\u00e9cessaires \u00e0 l'\u00e9valuation d'un projet de raccordement d'un syst\u00e8me de stockage d'\u00e9nergie par batterie (BESS) \u00e0 des fins commerciales au Nigeria ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-54312\" class=\"elementor-element elementor-element-f8294976 e-con-full e-flex e-con e-child\" data-id=\"f8294976\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-54312\" class=\"elementor-element elementor-element-8d7af79a e-con-full e-flex e-con e-child\" data-id=\"8d7af79a\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-1d21ce28 elementor-widget elementor-widget-heading\" data-id=\"1d21ce28\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Fournissez les relev\u00e9s de charge du site, le sch\u00e9ma unifilaire \u00e0 r\u00e9vision ma\u00eetris\u00e9e, les d\u00e9tails de l\u2019alimentation entrante, les donn\u00e9es du transformateur et du tableau, les informations sur le groupe \u00e9lectrog\u00e8ne s\u2019il existe, les priorit\u00e9s des charges critiques et les heures de fonctionnement requises. Pr\u00e9cisez les besoins en kW et en kVA, la dur\u00e9e, l\u2019objectif de commande et les conditions d\u2019installation locales. L\u2019entreprise EPC et l\u2019autorit\u00e9 \u00e9lectrique locale pourront alors faire correspondre le plan de raccordement d\u00e9taill\u00e9 aux autorisations applicables au projet.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-54313\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"14\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-54313\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Comment d\u00e9terminer la taille d'un syst\u00e8me de stockage d'\u00e9nergie \u00e0 usage professionnel \u00e0 partir des donn\u00e9es du site ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-54313\" class=\"elementor-element elementor-element-35b765f1 e-con-full e-flex e-con e-child\" data-id=\"35b765f1\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-54313\" class=\"elementor-element elementor-element-4a439c72 e-con-full e-flex e-con e-child\" data-id=\"4a439c72\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-b7e65ab7 elementor-widget elementor-widget-heading\" data-id=\"b7e65ab7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Commencez par d\u00e9finir les limites contr\u00f4l\u00e9es du PCC et les donn\u00e9es repr\u00e9sentatives de la charge par intervalle. D\u00e9finissez l'\u00e9cart de puissance active, les besoins en puissance apparente, la dur\u00e9e de l'\u00e9v\u00e9nement, les opportunit\u00e9s de recharge, la plage de facteur de puissance et les modes de fonctionnement. Examinez simultan\u00e9ment les interfaces relatives aux transformateurs, aux appareillages de commutation, aux protections et aux commandes. Ces donn\u00e9es permettent d'\u00e9tablir un profil de fonctionnement pr\u00e9liminaire du syst\u00e8me de stockage d'\u00e9nergie par batterie (BESS) avant que le mod\u00e8le s\u00e9lectionn\u00e9 et les documents du projet ne confirment la configuration finale.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-54314\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"15\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-54314\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Quels sont les crit\u00e8res qui permettent de d\u00e9terminer si une solution BESS commerciale de 100 kW ou de 125 kVA est adapt\u00e9e \u00e0 un site ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-54314\" class=\"elementor-element elementor-element-531dfe08 e-con-full e-flex e-con e-child\" data-id=\"531dfe08\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-54314\" class=\"elementor-element elementor-element-96eab11c e-con-full e-flex e-con e-child\" data-id=\"96eab11c\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-58845c32 elementor-widget elementor-widget-heading\" data-id=\"58845c32\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Comparez la charge mesur\u00e9e sur site avec la puissance active requise, la puissance apparente, le facteur de puissance, la dur\u00e9e de l'\u00e9v\u00e9nement, le calendrier de charge, la limite PCC et la tension de raccordement. Une valeur de 100 kW et une valeur de 125 kVA correspondent \u00e0 des grandeurs \u00e9lectriques diff\u00e9rentes. La fiche technique du mod\u00e8le s\u00e9lectionn\u00e9, l\u2019enveloppe PCS disponible et le trac\u00e9 de raccordement du site d\u00e9terminent si la configuration propos\u00e9e est adapt\u00e9e \u00e0 la charge.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-54315\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"16\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-54315\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Quels documents dois-je fournir pour une \u00e9valuation du raccordement d'un syst\u00e8me commercial de stockage d'\u00e9nergie ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-54315\" class=\"elementor-element elementor-element-3136acc9 e-con-full e-flex e-con e-child\" data-id=\"3136acc9\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-54315\" class=\"elementor-element elementor-element-794d94c2 e-con-full e-flex e-con e-child\" data-id=\"794d94c2\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a13ce0d3 elementor-widget elementor-widget-heading\" data-id=\"a13ce0d3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Transmettez le sch\u00e9ma unifilaire \u00e0 r\u00e9vision ma\u00eetris\u00e9e, les relev\u00e9s repr\u00e9sentatifs en kW et en kVA par intervalle, la limite au PCC, les donn\u00e9es du transformateur et de l\u2019appareillage, la puissance souhait\u00e9e en kW et sa dur\u00e9e, le facteur de puissance attendu, les donn\u00e9es de la production existante ou du groupe \u00e9lectrog\u00e8ne, les besoins de communication, l\u2019environnement du site et le format de r\u00e9ception. L\u2019\u00e9quipe technique pourra ainsi d\u00e9finir un p\u00e9rim\u00e8tre de BESS commercial adapt\u00e9 au projet.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Un syst\u00e8me commercial de stockage d'\u00e9nergie peut \u00eatre livr\u00e9 avant que le site ne soit pr\u00eat \u00e0 l'utiliser. V\u00e9rifiez les limites du PCC, du transformateur, du tableau \u00e9lectrique et de la charge, puis demandez un itin\u00e9raire de livraison pour la batterie MegSolid et le PCS en pr\u00e9cisant clairement le p\u00e9rim\u00e8tre de la fourniture et les travaux \u00e0 r\u00e9aliser sur site qui restent en suspens.<\/p>","protected":false},"author":4,"featured_media":4763,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"_joinchat":[],"footnotes":""},"categories":[1,710],"tags":[334,335,318,339,36,336,338,337],"class_list":["post-4766","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-bess","category-energy-storage-markets-policy","tag-bess-interconnection","tag-commercial-bess-sizing","tag-commercial-energy-storage-system","tag-epc-engineering","tag-MegSolid","tag-pcc-data","tag-pcs-kva","tag-transformer-capacity"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/posts\/4766","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/comments?post=4766"}],"version-history":[{"count":12,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/posts\/4766\/revisions"}],"predecessor-version":[{"id":8853,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/posts\/4766\/revisions\/8853"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/media\/4763"}],"wp:attachment":[{"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/media?parent=4766"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/categories?post=4766"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/tags?post=4766"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}