{"id":4786,"date":"2026-08-18T16:37:04","date_gmt":"2026-08-18T08:37:04","guid":{"rendered":"https:\/\/www.solidess.com\/?p=4786"},"modified":"2026-10-08T17:41:46","modified_gmt":"2026-10-08T09:41:46","slug":"systemes-de-stockage-denergie-par-batterie-au-nigeria","status":"publish","type":"post","link":"https:\/\/www.solidess.com\/fr\/battery-energy-storage-systems-in-nigeria\/","title":{"rendered":"BESS de 300 kW \/ 1 MWh au Nigeria : dimensionnement et exigences du devis"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"4786\" class=\"elementor elementor-4786\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-bf4793c e-con-full auto-article-root e-flex e-con e-parent\" data-id=\"bf4793c\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-6d891302 auto-p elementor-widget elementor-widget-heading\" data-id=\"6d891302\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Un BESS de 300 kW \/ 1 MWh fournit 3,33 heures \u00e0 pleine puissance nominale avant de tenir compte des limites d\u2019\u00e9tat de charge (SOC), des pertes de conversion, du d\u00e9classement li\u00e9 \u00e0 la temp\u00e9rature et du vieillissement de la batterie. Dans un projet commercial ou industriel au Nigeria, il faut donc calculer l\u2019\u00e9nergie utilisable avant que l\u2019EPC fixe le nombre d\u2019\u00e9quipements.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-bb45c1d8 auto-p elementor-widget elementor-widget-heading\" data-id=\"bb45c1d8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Avant de demander des devis, d\u00e9finissez la tension au point de raccordement (PCC), la puissance assign\u00e9e du transformateur, le profil de charge, les interfaces avec les groupes \u00e9lectrog\u00e8nes et le photovolta\u00efque, la r\u00e8gle d\u2019injection sur le r\u00e9seau, la r\u00e9serve de secours et les responsabilit\u00e9s de l\u2019EPC local. Ces donn\u00e9es permettent aux fournisseurs de chiffrer les m\u00eames exigences d\u2019exploitation \u00e9lectrique et le m\u00eame p\u00e9rim\u00e8tre de livraison.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9b447773 auto-p elementor-widget elementor-widget-heading\" data-id=\"9b447773\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\"><strong>Contexte de projet utilis\u00e9 pour cet article :<\/strong> une demande anonyme d\u2019un EPC nig\u00e9rian pour un projet commercial ou industriel de stockage d\u2019\u00e9nergie de type conteneur, install\u00e9 en ext\u00e9rieur, raccord\u00e9 au r\u00e9seau et destin\u00e9 \u00e0 alimenter de fortes charges industrielles. La demande indiquait 300 kW et 1 000 kWh. Les donn\u00e9es \u00e9lectriques, le profil de charge, l\u2019altitude du site et le p\u00e9rim\u00e8tre d\u00e9finitif des travaux sur site restaient \u00e0 confirmer par l\u2019\u00e9tude technique.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-679c0c85 auto-image elementor-widget elementor-widget-image\" data-id=\"679c0c85\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"1254\" height=\"1254\" src=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/Nigeria-300kW-1000kWh-BESS-Quote-Cover.png\" class=\"attachment-1536x1536 size-1536x1536 wp-image-4783\" alt=\"Armoire de stockage d&#039;\u00e9nergie MegSolid 261,24 kWh, 125 kVA, \u00e0 refroidissement par liquide, destin\u00e9e aux secteurs C et I, install\u00e9e dans un complexe \u00e9lectrique bien \u00e9clair\u00e9, accompagn\u00e9e d&#039;une configuration BESS nig\u00e9riane en cinq \u00e9tapes de 300 kW et 1 000 kWh, ainsi que du processus de d\u00e9cision relatif au devis\" srcset=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/Nigeria-300kW-1000kWh-BESS-Quote-Cover.png 1254w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/Nigeria-300kW-1000kWh-BESS-Quote-Cover-300x300.png 300w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/Nigeria-300kW-1000kWh-BESS-Quote-Cover-1024x1024.png 1024w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/Nigeria-300kW-1000kWh-BESS-Quote-Cover-150x150.png 150w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/Nigeria-300kW-1000kWh-BESS-Quote-Cover-768x768.png 768w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/Nigeria-300kW-1000kWh-BESS-Quote-Cover-600x600.png 600w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/Nigeria-300kW-1000kWh-BESS-Quote-Cover-100x100.png 100w\" sizes=\"(max-width: 1254px) 100vw, 1254px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-642be54e auto-h2 elementor-widget elementor-widget-heading\" data-id=\"642be54e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Comment dimensionner un BESS de 300 kW \/ 1 MWh au Nigeria<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d51b334f auto-p elementor-widget elementor-widget-heading\" data-id=\"d51b334f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Du point de vue commercial, la question est de savoir si la configuration peut assurer le service \u00e9lectrique demand\u00e9 lors de l\u2019\u00e9v\u00e9nement pr\u00e9vu sur le site concern\u00e9.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-404bdb1b elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"404bdb1b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Formulez le service requis sous la forme d\u2019une consigne d\u2019exploitation. Exemple : \u00ab Pendant la mont\u00e9e en r\u00e9gime de la production, maintenir le soutirage mesur\u00e9 dans la limite convenue pour le site, sur l\u2019intervalle enregistr\u00e9. \u00bb<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Distinguez la charge continue, la pointe temporaire, l'\u00e9v\u00e9nement de d\u00e9marrage moteur et les d\u00e9parts de charges critiques.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Indiquez si le BESS fonctionne en mode suivi de r\u00e9seau, soutient un jeu de barres en \u00eelotage, assure la continuit\u00e9 pendant un transfert de source ou combine ces fonctions selon des programmes distincts.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Relevez la tension au PCC, la puissance du transformateur, la disposition des d\u00e9parts, l'\u00e9tat du groupe \u00e9lectrog\u00e8ne existant et l'exigence de coordination des relais.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Identifiez le responsable du pilotage : l\u2019exploitant du site, l\u2019EMS du client, l\u2019EMS du fournisseur ou l\u2019int\u00e9grateur des automatismes de l\u2019EPC.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-54aa3fe1 auto-p elementor-widget elementor-widget-heading\" data-id=\"54aa3fe1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Pour un appel de charge de 300 kW, le rapport entre l\u2019\u00e9nergie nominale et la puissance, soit 1 000 kWh \u00f7 300 kW, donne 3,33 heures. Ce calcul sert de r\u00e9f\u00e9rence initiale. Pour \u00e9tablir l\u2019autonomie de dimensionnement, il faut tenir compte de la plage d\u2019\u00e9tat de charge convenue, des pertes de conversion, du d\u00e9classement li\u00e9 aux conditions ambiantes, de la marge de vieillissement de la batterie, de la consommation des auxiliaires et du profil de charge.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e8794019 auto-h3 elementor-widget elementor-widget-heading\" data-id=\"e8794019\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Les donn\u00e9es qui transforment une demande de capacit\u00e9 en base d'ing\u00e9nierie<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8df89835 auto-p elementor-widget elementor-widget-heading\" data-id=\"8df89835\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">L\u2019EPC peut r\u00e9unir les \u00e9l\u00e9ments suivants avant que le fabricant pr\u00e9pare une proposition soumise au contr\u00f4le documentaire.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e679f691 auto-table elementor-widget elementor-widget-text-editor\" data-id=\"e679f691\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"cea-table-wrap\"><table><thead><tr><th>Donn\u00e9e d'entr\u00e9e du projet<\/th><th>Justificatifs \u00e0 demander<\/th><th>D\u00e9cision \u00e0 \u00e9clairer<\/th><\/tr><\/thead><tbody><tr><td>Profil de charge<\/td><td>Au minimum, des relev\u00e9s par pas de 15 minutes, les \u00e9v\u00e9nements de pointe et le calendrier d\u2019exploitation<\/td><td>Puissance requise en courant alternatif et dur\u00e9e du service<\/td><\/tr><tr><td>PCC et transformateur<\/td><td>Sch\u00e9ma unifilaire, plaque signal\u00e9tique du transformateur et r\u00e9glages de protection<\/td><td>Tension de raccordement, courant et p\u00e9rim\u00e8tre de protection<\/td><\/tr><tr><td>Condition du r\u00e9seau<\/td><td>Historique des coupures, relev\u00e9 de qualit\u00e9 de tension et exigences du gestionnaire de r\u00e9seau<\/td><td>Choix du mode de commande : suivi du r\u00e9seau, secours ou micror\u00e9seau<\/td><\/tr><tr><td>Environnement du site<\/td><td>Implantation ext\u00e9rieure, voie d'acc\u00e8s, altitude, plage de temp\u00e9rature ambiante et plan de drainage<\/td><td>Revue de l'enveloppe, du refroidissement et du g\u00e9nie civil<\/td><\/tr><tr><td>Sources existantes<\/td><td>Caract\u00e9ristiques assign\u00e9es des groupes \u00e9lectrog\u00e8nes, caract\u00e9ristiques du contr\u00f4leur et configuration photovolta\u00efque locale<\/td><td>Coordination des sources et interfaces EMS<\/td><\/tr><tr><td>Objectif commercial<\/td><td>R\u00e9duction de la consommation de carburant, limite de soutirage du r\u00e9seau, r\u00e9silience, plages tarifaires ou continuit\u00e9 du proc\u00e9d\u00e9<\/td><td>Logique de pilotage et mod\u00e8le financier<\/td><\/tr><\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d8160a42 auto-p elementor-widget elementor-widget-heading\" data-id=\"d8160a42\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\"><strong>Pourquoi cela modifie le devis :<\/strong> sans ces donn\u00e9es, la seule plaque signal\u00e9tique de la batterie laisse place \u00e0 l\u2019interpr\u00e9tation sur la puissance assign\u00e9e du PCS, le nombre d\u2019enveloppes, les c\u00e2bles, l\u2019appareillage \u00e9lectrique, les travaux li\u00e9s au transformateur et le p\u00e9rim\u00e8tre du syst\u00e8me de commande.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8da3c2da auto-h2 elementor-widget elementor-widget-heading\" data-id=\"8da3c2da\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Distinguer la puissance active en courant alternatif, la puissance apparente et l\u2019\u00e9nergie de la batterie<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0cb91f23 auto-p elementor-widget elementor-widget-heading\" data-id=\"0cb91f23\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">La proposition doit expliquer, dans le contexte du projet, le lien entre les kW, les kVA et les kWh.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e15e0a97 elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"e15e0a97\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>kW<\/strong> d\u00e9crit la puissance AC active d\u00e9livr\u00e9e \u00e0 la charge ou g\u00e9r\u00e9e au PCC.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>kVA<\/strong> d\u00e9signe la puissance apparente en courant alternatif, \u00e0 examiner avec le facteur de puissance du site.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>kWh<\/strong> d\u00e9signe l\u2019\u00e9nergie nominale stock\u00e9e. L\u2019\u00e9nergie utilisable d\u00e9pend des limites d\u2019exploitation du projet.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>La plage de tension continue<\/strong> influe sur le choix d\u2019un PCS et d\u2019une configuration de batteries compatibles.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>La puissance de charge<\/strong> d\u00e9termine si la batterie peut se recharger pendant la p\u00e9riode disponible de faible charge ou de bas tarif.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b91ceb6a auto-p elementor-widget elementor-widget-heading\" data-id=\"b91ceb6a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Dans la gamme actuelle de MegSolid, la cat\u00e9gorie <strong><a href=\"https:\/\/www.solidess.com\/fr\/piles\/onduleur-de-stockage-denergie\/\" target=\"_blank\" style=\"color:#61ce70\">onduleur de stockage d'\u00e9nergie<\/a><\/strong> comprend la s\u00e9rie de PCS MEGA0030TS\u2013MEGA0500TS. Les puissances assign\u00e9es publi\u00e9es vont de 30 kW \u00e0 500 kW. Ces mod\u00e8les pr\u00e9sentent une tension assign\u00e9e de 400 V en courant alternatif, un transformateur d\u2019isolement int\u00e9gr\u00e9, une distorsion harmonique totale du courant r\u00e9seau inf\u00e9rieure \u00e0 3 %, un facteur de puissance r\u00e9glable et des communications RS485\/CAN ainsi que RS485\/TCP-IP. Une demande de 300 kW doit donc pr\u00e9ciser la topologie des PCS, la combinaison de mod\u00e8les retenue et le sch\u00e9ma des interfaces, au-del\u00e0 du simple libell\u00e9 \u00ab onduleur \u00bb dans le devis.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4b9aa06f auto-table elementor-widget elementor-widget-text-editor\" data-id=\"4b9aa06f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"cea-table-wrap\"><table><thead><tr><th>Question de configuration<\/th><th>Justificatifs techniques du p\u00e9rim\u00e8tre propos\u00e9<\/th><\/tr><\/thead><tbody><tr><td>Le syst\u00e8me peut-il fournir 300 kW au facteur de puissance correspondant au fonctionnement pr\u00e9vu ?<\/td><td>Tableau des PCS retenus, valeurs d\u00e9clar\u00e9es en kW et en kVA, et calcul du courant alternatif<\/td><\/tr><tr><td>Une \u00e9nergie de 1 000 kWh suffit-elle pendant la dur\u00e9e de fonctionnement exig\u00e9e ?<\/td><td>\u00c9nergie nominale, plage de SOC d'exploitation, marge de vieillissement et calcul du cycle de service<\/td><\/tr><tr><td>Le syst\u00e8me peut-il se recharger entre les \u00e9v\u00e9nements ?<\/td><td>Limite de puissance de charge, disponibilit\u00e9 de la source et programme EMS<\/td><\/tr><tr><td>La conduite pr\u00e9vue est-elle compatible avec le point de raccordement (PCC) ?<\/td><td>Sch\u00e9ma unifilaire, r\u00e9glages de protection et revue par le gestionnaire de r\u00e9seau\/l'EPC<\/td><\/tr><tr><td>Le site peut-il maintenir la puissance pr\u00e9vue ?<\/td><td>Hypoth\u00e8ses sur les conditions ambiantes, agencement de l\u2019enveloppe et calcul de la puissance des auxiliaires<\/td><\/tr><\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-cb952042 auto-image elementor-widget elementor-widget-image\" data-id=\"cb952042\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"1448\" height=\"1086\" src=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/Nigeria-300kW-1000kWh-Power-Energy-Review.png\" class=\"attachment-1536x1536 size-1536x1536 wp-image-4784\" alt=\"Comparaison technique pour un projet BESS commercial de 300kW 1000kWh au Nigeria : quatre armoires refroidies par liquide de 261,24kWh 125kVA et une r\u00e9f\u00e9rence de BESS en conteneur de 500kW 1,0752MWh, avec contr\u00f4les de d\u00e9cision sur site\" srcset=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/Nigeria-300kW-1000kWh-Power-Energy-Review.png 1448w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/Nigeria-300kW-1000kWh-Power-Energy-Review-300x225.png 300w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/Nigeria-300kW-1000kWh-Power-Energy-Review-1024x768.png 1024w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/Nigeria-300kW-1000kWh-Power-Energy-Review-768x576.png 768w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/Nigeria-300kW-1000kWh-Power-Energy-Review-600x450.png 600w\" sizes=\"(max-width: 1448px) 100vw, 1448px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-39b88c85 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"39b88c85\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Options de configuration d\u2019un BESS de 300 kW \/ 1 MWh<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-52f49797 auto-p elementor-widget elementor-widget-heading\" data-id=\"52f49797\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">MegSolid publie plusieurs familles de produits C&amp;I et en conteneur qui peuvent nourrir une discussion d'ing\u00e9nierie pr\u00e9liminaire.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e05bd241 auto-table elementor-widget elementor-widget-text-editor\" data-id=\"e05bd241\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"cea-table-wrap\"><table><thead><tr><th>Options fond\u00e9es sur la gamme publi\u00e9e<\/th><th>Caract\u00e9ristiques nominales publiques v\u00e9rifi\u00e9es<\/th><th>R\u00f4le dans l\u2019\u00e9tude d\u2019un syst\u00e8me de 300 kW \/ 1 000 kWh<\/th><th>Confirmation d'ing\u00e9nierie requise<\/th><\/tr><\/thead><tbody><tr><td>Armoire d'ext\u00e9rieur ESSA0100B-0215<\/td><td>100 kW CA ; 215,04 kWh ; LFP ; refroidissement par air intelligent<\/td><td>\u00c0 titre de r\u00e9f\u00e9rence arithm\u00e9tique, la somme des caract\u00e9ristiques nominales publi\u00e9es de trois unit\u00e9s donne 300 kW en courant alternatif et 645,12 kWh d\u2019\u00e9nergie nominale<\/td><td>Autonomie, architecture des armoires, syst\u00e8me de commande, c\u00e2blage sur site et conditions d\u2019implantation<\/td><\/tr><tr><td><strong><span style=\"color: #61ce70;\"><a style=\"color: #61ce70;\" href=\"https:\/\/www.solidess.com\/fr\/product\/stockage-denergie-solide-liquide-megasolide\/\">Syst\u00e8me C&amp;I refroidi par liquide Meg-SolidEnergon-261kWh<\/a><\/span><\/strong><\/td><td>125kVA ; 261,24kWh ; LFP 314Ah ; refroidissement liquide<\/td><td>Quatre unit\u00e9s totalisent 500 kVA et 1,04496 MWh d\u2019\u00e9nergie nominale avant prise en compte des limites d\u2019exploitation<\/td><td>Limite de puissance active retenue pour le pilotage en kW, facteur de puissance, architecture en parall\u00e8le, interface au PCC et p\u00e9rim\u00e8tre d\u2019installation<\/td><\/tr><tr><td>MEGA TS PCS<\/td><td>Puissance nominale de 30\u2013500kW selon le mod\u00e8le ; transformateur d'isolement<\/td><td>Fournit une cha\u00eene de conversion d\u00e9finie c\u00f4t\u00e9 courant alternatif pour des architectures de batteries \u00e9tudi\u00e9es pour le projet<\/td><td>Quantit\u00e9 de PCS retenue, compatibilit\u00e9 des batteries, appareillage, protection et BOP<\/td><\/tr><tr><td>BESS en conteneur ESSC0500B-1075<\/td><td>500kW ; 1,0752MWh ; LFP ; refroidissement par air \u00e0 r\u00e9gulation de temp\u00e9rature intelligente<\/td><td>R\u00e9f\u00e9rence de BESS en conteneur dont l\u2019\u00e9nergie est proche de celle demand\u00e9e<\/td><td>Strat\u00e9gie de pilotage \u00e0 300 kW, implantation, contr\u00f4le du soutirage et de l\u2019injection, g\u00e9nie civil et p\u00e9rim\u00e8tre de livraison<\/td><\/tr><\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-348bb1cb auto-p elementor-widget elementor-widget-heading\" data-id=\"348bb1cb\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Le tableau sert \u00e0 comparer les options sans garantir que l\u2019une d\u2019elles convienne telle quelle au projet. Chaque solution finale exige une fiche technique sous contr\u00f4le documentaire, un sch\u00e9ma unifilaire, une nomenclature (BOM), des limites thermiques d\u00e9finies et le p\u00e9rim\u00e8tre des certifications applicables.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e9dc9fe4 auto-p elementor-widget elementor-widget-heading\" data-id=\"e9dc9fe4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Pour d\u00e9cider entre un d\u00e9ploiement en armoires et un d\u00e9ploiement en conteneur, consultez la comparaison entre <strong><a href=\"https:\/\/www.solidess.com\/fr\/armoires-modulaires-vs-ess-conteneurise\/\" target=\"_blank\" style=\"color:#61ce70\">les armoires modulaires et les syst\u00e8mes ESS en conteneur<\/a><\/strong>. Une architecture modulaire peut faciliter les livraisons par \u00e9tapes et permettre de segmenter le service. Une architecture conteneuris\u00e9e peut regrouper davantage d\u2019\u00e9quipements dans une seule enveloppe d\u00e9finie en usine. Le cheminement pr\u00e9vu pour le levage sur site, la surface de fondation, la s\u00e9paration \u00e9lectrique, les d\u00e9gagements d\u2019acc\u00e8s et le plan de service d\u00e9terminent l\u2019option adapt\u00e9e au projet.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-49e57368 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"49e57368\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Donn\u00e9es de comptage au PCC et de raccordement r\u00e9seau pour le site nig\u00e9rian<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ba682d86 auto-p elementor-widget elementor-widget-heading\" data-id=\"ba682d86\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">La facture, le point \u00e9lectrique et le p\u00e9rim\u00e8tre de commande doivent correspondre au m\u00eame sc\u00e9nario de fonctionnement du projet.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-56eb4766 elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"56eb4766\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Identifiez si le BESS est pilot\u00e9 d\u2019apr\u00e8s le soutirage du r\u00e9seau, un d\u00e9part en aval, une branche alimentant un proc\u00e9d\u00e9 ou un jeu de barres desservant les charges critiques.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Consignez l\u2019intervalle de comptage, la p\u00e9riode de calcul de la puissance appel\u00e9e, la limite de soutirage et les conditions d\u2019injection autoris\u00e9es.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">D\u00e9finissez comment l'EMS re\u00e7oit les valeurs de compteur, l'\u00e9tat du groupe \u00e9lectrog\u00e8ne et les \u00e9tats de fonctionnement du PCS.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Documentez qui fournit les TC, le compteur, la passerelle, l'\u00e9quipement r\u00e9seau, les c\u00e2bles de commande et l'acc\u00e8s aux donn\u00e9es.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Confirmez le comportement approuv\u00e9 lors d'une coupure du r\u00e9seau, d'une maintenance planifi\u00e9e et d'une perte de communication.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-994db154 auto-p elementor-widget elementor-widget-heading\" data-id=\"994db154\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Pour les projets o\u00f9 la stabilit\u00e9 du r\u00e9seau et l\u2019alimentation de secours interagissent avec le fonctionnement du groupe \u00e9lectrog\u00e8ne, les questions d\u2019exploitation propres au Nigeria abord\u00e9es dans <strong><a href=\"https:\/\/www.solidess.com\/fr\/conception-de-micro-reseaux-hybrides-pv-diesel-bess-pour-le-nigeria\/\" target=\"_blank\" style=\"color:#61ce70\">l'ing\u00e9nierie de micror\u00e9seaux PV-diesel-BESS pour le Nigeria<\/a><\/strong> aident le contractant EPC \u00e0 d\u00e9finir l\u2019ordre de priorit\u00e9 des sources et le transfert de la commande. MegSolid fournit les \u00e9quipements de stockage et les interfaces de commande. Les modules photovolta\u00efques et les autres \u00e9quipements n\u00e9cessaires \u00e0 l\u2019installation photovolta\u00efque sont \u00e0 fournir dans le lot local du projet.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-cffe0960 auto-h3 elementor-widget elementor-widget-heading\" data-id=\"cffe0960\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Une consigne de pilotage commune aux achats et \u00e0 l\u2019ing\u00e9nierie<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-32bb4440 auto-p elementor-widget elementor-widget-heading\" data-id=\"32bb4440\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Utilisez un court \u00e9nonc\u00e9 op\u00e9rationnel dans le dossier d'appel d'offres.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9a4fb272 auto-p elementor-widget elementor-widget-heading\" data-id=\"9a4fb272\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\"><strong>\u00c9nonc\u00e9 d'exploitation :<\/strong> Pendant la p\u00e9riode d\u2019exploitation industrielle d\u00e9finie, maintenir le soutirage au PCC \u00e0 un niveau qui ne d\u00e9passe pas le seuil convenu, tout en pr\u00e9servant la r\u00e9serve d\u2019\u00e9nergie convenue pour le service de secours sp\u00e9cifi\u00e9.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-02e0930f auto-p elementor-widget elementor-widget-heading\" data-id=\"02e0930f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Cet \u00e9nonc\u00e9 donne \u00e0 l\u2019\u00e9quipe financi\u00e8re une situation d\u2019exploitation dont le b\u00e9n\u00e9fice est v\u00e9rifiable, \u00e0 l\u2019ing\u00e9nierie un objectif mesurable c\u00f4t\u00e9 courant alternatif, et aux fournisseurs une base commune pour la logique de pilotage.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-47c14bc8 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"47c14bc8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Ce qu'il faut inclure dans un devis BESS commercial nig\u00e9rian<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-164fd6f2 auto-p elementor-widget elementor-widget-heading\" data-id=\"164fd6f2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Une comparaison compl\u00e8te s\u00e9pare les \u00e9quipements fournis par l'usine des responsabilit\u00e9s de l'EPC et du site.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-81331139 auto-table elementor-widget elementor-widget-text-editor\" data-id=\"81331139\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"cea-table-wrap\"><table><thead><tr><th>Domaine de p\u00e9rim\u00e8tre<\/th><th>La proposition du fabricant devrait pr\u00e9ciser<\/th><th>Le contractant EPC ou l\u2019intervenant sur site devrait pr\u00e9ciser<\/th><\/tr><\/thead><tbody><tr><td>Batterie et PCS<\/td><td>Mod\u00e8le, quantit\u00e9, kW\/kVA nominaux, kWh nominaux, limites d'exploitation, interface BMS\/EMS<\/td><td>Cycle de service final, emplacement retenu et voie d'acc\u00e8s<\/td><\/tr><tr><td>Interface AC<\/td><td>Bornes, tension, courant, donn\u00e9es du transformateur et interface de protection<\/td><td>Disjoncteur du PCC, appareillage aval, cheminement des c\u00e2bles et coordination des relais<\/td><\/tr><tr><td>Enveloppe et syst\u00e8me thermique<\/td><td>Indice de protection IP, m\u00e9thode de refroidissement, charges auxiliaires et acc\u00e8s pour la maintenance<\/td><td>Fondation, drainage, d\u00e9cision sur la n\u00e9cessit\u00e9 d\u2019un auvent et ventilation autour des \u00e9quipements<\/td><\/tr><tr><td>Commandes<\/td><td>Protocoles de communication de l\u2019EMS, donn\u00e9es de comptage requises et modes d\u2019exploitation<\/td><td>Propri\u00e9t\u00e9 du r\u00e9seau, politique d'acc\u00e8s \u00e0 distance et autorit\u00e9 de commande locale<\/td><\/tr><tr><td>Mise en service<\/td><td>Justificatifs des essais de r\u00e9ception en usine (FAT), p\u00e9rim\u00e8tre des essais sur site et dossier documentaire<\/td><td>Coordination avec le gestionnaire de r\u00e9seau, autorisations \u00e9lectriques, installation sur site et mise sous tension en pr\u00e9sence d\u2019un t\u00e9moin<\/td><\/tr><tr><td>Logistique<\/td><td>Liste de colisage d'usine, points de levage et interface d'exp\u00e9dition<\/td><td>Douane locale, \u00e9quipements de d\u00e9chargement, acc\u00e8s routier et plan de levage du site<\/td><\/tr><\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c1942251 auto-p elementor-widget elementor-widget-heading\" data-id=\"c1942251\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default translation-block\">Utilisez <strong><a href=\"https:\/\/www.solidess.com\/fr\/liste-de-controle-des-marches-publics-de-ci-bess-2026\/\" target=\"_blank\" style=\"color:#61ce70\">la liste de contr\u00f4le pour l\u2019acquisition d\u2019un BESS commercial et industriel (C&amp;I)<\/a><\/strong> pour regrouper les hypoth\u00e8ses techniques et commerciales dans un m\u00eame dossier de comparaison. La proposition produit, le fret, l\u2019installation locale, les travaux de c\u00e2blage externe, la demande aupr\u00e8s du gestionnaire de r\u00e9seau, le g\u00e9nie civil et le p\u00e9rim\u00e8tre de mise en service devraient chacun avoir un responsable identifi\u00e9.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-88fa8175 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"88fa8175\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">V\u00e9rifier les interfaces PCS, BMS et EMS avant l'approbation d'achat<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d9f3025d auto-p elementor-widget elementor-widget-heading\" data-id=\"d9f3025d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">L\u2019int\u00e9gration des commandes d\u00e9termine si un syst\u00e8me de batteries correctement dimensionn\u00e9 peut assurer le service pr\u00e9vu.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d4df32a2 elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"d4df32a2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">V\u00e9rifiez que la plage de tension continue du PCS retenu correspond \u00e0 la configuration de batterie valid\u00e9e.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Recensez les signaux \u00e9chang\u00e9s du BMS vers le PCS, les conditions d\u2019autorisation, les alarmes, les consignes et la s\u00e9quence d\u2019arr\u00eat d\u2019urgence.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Cartographiez les \u00e9changes de donn\u00e9es entre l\u2019EMS et le compteur, les ordres de pilotage, l\u2019\u00e9tat des sources et les commandes \u00e0 disposition de l\u2019op\u00e9rateur.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Pr\u00e9cisez qui commande localement et \u00e0 distance, qui g\u00e8re les mots de passe et comment le r\u00e9seau est segment\u00e9.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Incluez un \u00e9tat de perte de communication dans la description fonctionnelle.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-52fda610 auto-p elementor-widget elementor-widget-heading\" data-id=\"52fda610\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default translation-block\"><strong><a href=\"https:\/\/www.solidess.com\/fr\/pourquoi-lintegration-du-pcs-et-du-bms-echoue\/\" target=\"_blank\" style=\"color:#61ce70\">L\u2019analyse de l\u2019int\u00e9gration du PCS et du BMS<\/a><\/strong> propose des questions utiles pour cette v\u00e9rification. La matrice de communication du projet est le document cl\u00e9, car elle relie les caract\u00e9ristiques nominales des \u00e9quipements \u00e0 leur logique de fonctionnement r\u00e9elle.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-84bcf489 auto-image elementor-widget elementor-widget-image\" data-id=\"84bcf489\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"1448\" height=\"1086\" src=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/Nigeria-300kW-1000kWh-PCC-Quote-Boundary.png\" class=\"attachment-1536x1536 size-1536x1536 wp-image-4785\" alt=\"Infographie du p\u00e9rim\u00e8tre d&#039;un devis BESS commercial EXW pour le Nigeria montrant la fronti\u00e8re du PCC, la fourniture d&#039;usine, les achats locaux, les travaux EPC et la responsabilit\u00e9 du site\" srcset=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/Nigeria-300kW-1000kWh-PCC-Quote-Boundary.png 1448w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/Nigeria-300kW-1000kWh-PCC-Quote-Boundary-300x225.png 300w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/Nigeria-300kW-1000kWh-PCC-Quote-Boundary-1024x768.png 1024w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/Nigeria-300kW-1000kWh-PCC-Quote-Boundary-768x576.png 768w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/Nigeria-300kW-1000kWh-PCC-Quote-Boundary-600x450.png 600w\" sizes=\"(max-width: 1448px) 100vw, 1448px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e413f379 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"e413f379\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Utiliser les preuves de r\u00e9ception pour prot\u00e9ger la d\u00e9cision commerciale<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a13940aa auto-p elementor-widget elementor-widget-heading\" data-id=\"a13940aa\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Les essais de mise en service devraient v\u00e9rifier le service d\u00e9clar\u00e9 pour le projet. Une d\u00e9monstration g\u00e9n\u00e9rique de l\u2019armoire ne couvre pas ce service.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3c87e23a elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"3c87e23a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">V\u00e9rifiez l\u2019identit\u00e9 des \u00e9quipements par rapport \u00e0 la nomenclature (BOM) approuv\u00e9e, aux plaques signal\u00e9tiques et aux fiches techniques soumises \u00e0 la ma\u00eetrise documentaire.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">V\u00e9rifiez la limite kW\/kVA AC retenue et le r\u00e9glage du facteur de puissance \u00e0 l'interface convenue.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">R\u00e9alisez et documentez un essai de pilotage au p\u00e9rim\u00e8tre de comptage d\u00e9fini pour le projet.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">V\u00e9rifiez les alarmes, les conditions d\u2019autorisation et la remont\u00e9e des \u00e9tats du BMS, du PCS et de l\u2019EMS.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">V\u00e9rifiez le bilan \u00e9nerg\u00e9tique en tenant compte de la p\u00e9riode d\u2019essai convenue et de l\u2019\u00e9tat de charge initial (SOC).<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Consignez les r\u00e9glages du site, les versions logicielles, les compteurs d'essai et les actions restantes dans un rapport sign\u00e9.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b0df5e15 auto-p elementor-widget elementor-widget-heading\" data-id=\"b0df5e15\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default translation-block\"><strong><a href=\"https:\/\/www.solidess.com\/fr\/guide-dessai-de-reception-en-usine-de-bess\/\" target=\"_blank\" style=\"color:#61ce70\">La liste de contr\u00f4le des essais de r\u00e9ception en usine du BESS en pr\u00e9sence de t\u00e9moins<\/a><\/strong> peut \u00eatre adapt\u00e9e au p\u00e9rim\u00e8tre d\u00e9fini pour les essais en usine. La r\u00e9ception sur site devrait ensuite valider le cheminement des c\u00e2bles install\u00e9s, le comportement au PCC, l\u2019int\u00e9gration des commandes et le service \u00e0 assurer en exploitation.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b5bcd1e1 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"b5bcd1e1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Choisir la prochaine action commerciale<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-960e5abc auto-p elementor-widget elementor-widget-heading\" data-id=\"960e5abc\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">L'\u00e9tape suivante est un dossier de donn\u00e9es de projet concis permettant aux \u00e9quipes techniques et commerciales de pr\u00e9parer une proposition comparable.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-729e8e8d elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"729e8e8d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Historique des charges par intervalles de 15 minutes et programme d\u2019exploitation pr\u00e9vu<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Sch\u00e9ma unifilaire, tension au PCC, puissance du transformateur et philosophie de protection<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Service \u00e0 assurer \u00e0 300 kW, dur\u00e9e cible et r\u00e9serve destin\u00e9e aux charges critiques<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">\u00c9tat du r\u00e9seau, du groupe \u00e9lectrog\u00e8ne et du PV local<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Implantation ext\u00e9rieure, altitude du site, acc\u00e8s et contraintes d'installation<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Matrice de responsabilit\u00e9s pour les c\u00e2bles externes, le g\u00e9nie civil, l'installation, le fret et la mise en service<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8862d857 auto-p elementor-widget elementor-widget-heading\" data-id=\"8862d857\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Pour disposer d\u2019un cadre d\u2019\u00e9valuation EPC, voyez <strong><a href=\"https:\/\/www.solidess.com\/fr\/les-epcs-evaluent-les-systemes-de-stockage-denergie\/\" target=\"_blank\" style=\"color:#61ce70\">comment les EPC \u00e9valuent les syst\u00e8mes de stockage d'\u00e9nergie dans le d\u00e9ploiement de projets<\/a><\/strong>. Pour effectuer les v\u00e9rifications pr\u00e9alables propres aux fournisseurs du pays, consultez <strong><a href=\"https:\/\/www.solidess.com\/fr\/fournisseur-de-systemes-de-stockage-denergie-par-batterie-au-nigeria\/\" target=\"_blank\" style=\"color:#61ce70\">l'\u00e9valuation des fournisseurs de stockage d'\u00e9nergie par batterie au Nigeria<\/a><\/strong>.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-015b70c6 elementor-tablet-align-center elementor-align-center auto-cta elementor-widget elementor-widget-button\" data-id=\"015b70c6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"#elementor-action%3Aaction%3Dpopup%3Aopen%26settings%3DeyJpZCI6Ijk0OCIsInRvZ2dsZSI6ZmFsc2V9\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Demander une revue du p\u00e9rim\u00e8tre \u00e9lectrique 300kW\/1MWh au Nigeria<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a30fd8a4 elementor-tablet-align-center elementor-align-center auto-cta elementor-widget elementor-widget-button\" data-id=\"a30fd8a4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"#elementor-action%3Aaction%3Dpopup%3Aopen%26settings%3DeyJpZCI6Ijk0OCIsInRvZ2dsZSI6ZmFsc2V9\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Demander une comparaison armoire, PCS et conteneur<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-d20d6ce0 auto-faq e-flex e-con-boxed e-con e-child\" data-id=\"d20d6ce0\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-4ea6d4db elementor-widget elementor-widget-heading\" data-id=\"4ea6d4db\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">FAQ<\/h2>\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-264bdb3f e-con-full e-flex e-con e-child\" data-id=\"264bdb3f\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-1f95ac19 elementor-widget elementor-widget-n-accordion\" data-id=\"1f95ac19\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;default_state&quot;:&quot;all_collapsed&quot;,&quot;max_items_expended&quot;:&quot;one&quot;,&quot;n_accordion_animation_duration&quot;:{&quot;unit&quot;:&quot;ms&quot;,&quot;size&quot;:400,&quot;sizes&quot;:[]}}\" data-widget_type=\"nested-accordion.default\">\n\t\t\t\t\t\t\t<div class=\"e-n-accordion\" aria-label=\"Accord\u00e9on. Ouvrez les liens \u00e0 l&#039;aide de la touche Entr\u00e9e ou de la barre d&#039;espace, fermez-les avec la touche \u00c9chap et naviguez \u00e0 l&#039;aide des touches fl\u00e9ch\u00e9es.\">\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-5290\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"1\" tabindex=\"0\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-5290\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Que signifie 300kW dans un syst\u00e8me commercial de stockage d'\u00e9nergie par batterie ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-5290\" class=\"elementor-element elementor-element-6ed9ff66 e-con-full e-flex e-con e-child\" data-id=\"6ed9ff66\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-5290\" class=\"elementor-element elementor-element-a6b0042f e-con-full e-flex e-con e-child\" data-id=\"a6b0042f\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-258de686 elementor-widget elementor-widget-heading\" data-id=\"258de686\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">300 kW correspond \u00e0 la puissance active en courant alternatif que le syst\u00e8me doit fournir ou g\u00e9rer au p\u00e9rim\u00e8tre \u00e9lectrique d\u00e9clar\u00e9. Le cahier des charges du projet doit pr\u00e9ciser le facteur de puissance, le courant, les exigences relatives aux pointes transitoires et le mode de commande.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-5291\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"2\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-5291\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> 1 000kWh fournissent-ils toujours 3,33 heures \u00e0 300kW ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-5291\" class=\"elementor-element elementor-element-7ec6e4e5 e-con-full e-flex e-con e-child\" data-id=\"7ec6e4e5\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-5291\" class=\"elementor-element elementor-element-288cb8dd e-con-full e-flex e-con e-child\" data-id=\"288cb8dd\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-8ad61bc3 elementor-widget elementor-widget-heading\" data-id=\"8ad61bc3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Le quotient nominal est de 3,33 heures. La dur\u00e9e finale d\u00e9coule du calcul du cycle de service du projet et de la r\u00e9serve d'exploitation d\u00e9clar\u00e9e.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-5292\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"3\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-5292\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Le projet doit-il sp\u00e9cifier des kW ou des kVA ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-5292\" class=\"elementor-element elementor-element-58249941 e-con-full e-flex e-con e-child\" data-id=\"58249941\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-5292\" class=\"elementor-element elementor-element-8b20b21d e-con-full e-flex e-con e-child\" data-id=\"8b20b21d\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-89731c14 elementor-widget elementor-widget-heading\" data-id=\"89731c14\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Pr\u00e9cisez les deux lorsque le facteur de puissance du site influe sur le service \u00e0 assurer. Les kW indiquent la puissance active. Les kVA indiquent la puissance apparente et la capacit\u00e9 de l\u2019\u00e9quipement \u00e0 supporter le courant requis.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-5293\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"4\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-5293\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Quels documents le contractant EPC devrait-il fournir avant de demander une offre BESS dont la documentation est ma\u00eetris\u00e9e ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-5293\" class=\"elementor-element elementor-element-8958a4e5 e-con-full e-flex e-con e-child\" data-id=\"8958a4e5\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-5293\" class=\"elementor-element elementor-element-540e3d1e e-con-full e-flex e-con e-child\" data-id=\"540e3d1e\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-969cc05b elementor-widget elementor-widget-heading\" data-id=\"969cc05b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Fournissez les donn\u00e9es de charge par intervalles, un sch\u00e9ma unifilaire, les informations sur le PCC et le transformateur, le programme d'exploitation, les informations sur les sources, le plan d'implantation du site et la matrice de responsabilit\u00e9s pour les travaux externes.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-5294\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"5\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-5294\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Un BESS de 300kW\/1 000kWh peut-il fonctionner avec le r\u00e9seau nig\u00e9rian ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-5294\" class=\"elementor-element elementor-element-679d7d4b e-con-full e-flex e-con e-child\" data-id=\"679d7d4b\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-5294\" class=\"elementor-element elementor-element-9da17250 e-con-full e-flex e-con e-child\" data-id=\"9da17250\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-feffbaa1 elementor-widget elementor-widget-heading\" data-id=\"feffbaa1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Le fonctionnement raccord\u00e9 au r\u00e9seau d\u00e9pend des caract\u00e9ristiques du PCC, des exigences du gestionnaire de r\u00e9seau, du mode de commande du PCS retenu, de la coordination des protections et de la conception d'installation approuv\u00e9e. Ces donn\u00e9es n\u00e9cessitent une confirmation propre au site.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-5295\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"6\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-5295\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Outre la capacit\u00e9 de la batterie, quels \u00e9l\u00e9ments influent sur le devis d\u2019un BESS commercial ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-5295\" class=\"elementor-element elementor-element-fcc3b20b e-con-full e-flex e-con e-child\" data-id=\"fcc3b20b\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-5295\" class=\"elementor-element elementor-element-7cde0d81 e-con-full e-flex e-con e-child\" data-id=\"7cde0d81\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-7ab162e3 elementor-widget elementor-widget-heading\" data-id=\"7ab162e3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Le devis d\u00e9pend de la puissance du PCS, de l\u2019\u00e9nergie de la batterie, du service \u00e0 assurer en exploitation, de l\u2019interface avec le transformateur et l\u2019appareillage \u00e9lectrique, des c\u00e2bles, des commandes, de l\u2019enveloppe, du syst\u00e8me thermique, des conditions de livraison, de la mise en service et des travaux locaux du contractant EPC.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>D\u00e9finir l'alimentation en courant alternatif, l'\u00e9nergie nominale, les contr\u00f4les PCC et le p\u00e9rim\u00e8tre de livraison pour un projet commercial de syst\u00e8me de stockage d'\u00e9nergie par batterie (BESS) de 300 kW\/1 000 kWh au Nigeria.<\/p>","protected":false},"author":4,"featured_media":4783,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"_joinchat":[],"footnotes":""},"categories":[1,713],"tags":[345,344,97,31,346,36,343],"class_list":["post-4786","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-bess","category-bess-procurement-economics","tag-1000kwh-bess","tag-300kw-bess","tag-battery-energy-storage-system","tag-ci-energy-storage","tag-commercial-bess-quote","tag-MegSolid","tag-nigeria-bess"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/posts\/4786","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/comments?post=4786"}],"version-history":[{"count":5,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/posts\/4786\/revisions"}],"predecessor-version":[{"id":5426,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/posts\/4786\/revisions\/5426"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/media\/4783"}],"wp:attachment":[{"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/media?parent=4786"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/categories?post=4786"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/tags?post=4786"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}