{"id":4824,"date":"2026-08-13T17:23:32","date_gmt":"2026-08-13T09:23:32","guid":{"rendered":"https:\/\/www.solidess.com\/?p=4824"},"modified":"2026-10-13T19:24:20","modified_gmt":"2026-10-13T11:24:20","slug":"guide-de-dimensionnement-et-dintervalle-de-demande-de-bess-pour-le-demarrage-des-moteurs","status":"publish","type":"post","link":"https:\/\/www.solidess.com\/fr\/bess-for-motor-starting-pcs-sizing-and-demand-interval-guide\/","title":{"rendered":"BESS pour le d\u00e9marrage des moteurs : guide de dimensionnement des PCS et des intervalles de demande"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"4824\" class=\"elementor elementor-4824\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-bf4793c e-con-full auto-article-root e-flex e-con e-parent\" data-id=\"bf4793c\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-382d3cef auto-p elementor-widget elementor-widget-heading\" data-id=\"382d3cef\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Every failed extruder start costs production time; a high tariff interval costs money even when the line keeps running. A BESS for motor starting has to address the right problem. Voltage sag may require short-duration PCS kVA and reactive-power headroom, while a high 15- or 30-minute demand interval requires usable BESS energy and a recharge plan. Use the measurements to separate those duties before buying a cabinet; extra kWh alone cannot fix a power-converter shortfall.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-eb7f182d auto-p elementor-widget elementor-widget-heading\" data-id=\"eb7f182d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">En ce qui concerne le droit applicable aux installations de recyclage vis\u00e9 ici, le produit faisant l'objet de l'examen est le <strong><a href=\"https:\/\/www.solidess.com\/fr\/product\/systeme-de-stockage-denergie-en-armoire-exterieure\/\" target=\"_blank\" style=\"color:#61ce70\">Armoire d'ext\u00e9rieur MegSolid ESSA0100B-0215<\/a><\/strong>. Sa puissance nominale en courant alternatif de 100 kW et sa capacit\u00e9 nominale de 215,04 kWh, telles qu'elles sont indiqu\u00e9es, en font un point de d\u00e9part raisonnable pour une mission mesur\u00e9e de gestion des pics de puissance de la classe des 100 kW. Ces chiffres ne prouvent toutefois pas, \u00e0 eux seuls, qu'il soit capable de prendre en charge chaque d\u00e9marrage de moteur de 132 kW. Ce sont la courbe du moteur, le transformateur, la ligne d\u2019alimentation, les dispositifs de protection et les limites P-Q du PCS qui en d\u00e9cident.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b0a9a2b2 elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"b0a9a2b2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">D\u00e9terminez la nature du probl\u00e8me : s'agit-il d'un \u00e9v\u00e9nement de tension de courte dur\u00e9e, d'un \u00e9v\u00e9nement li\u00e9 \u00e0 la demande au cours d'une p\u00e9riode de facturation, ou des deux ?.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Mesurez la puissance en kW, le facteur de puissance en kVAr, la puissance apparente en kVA et la tension au point de raccordement au r\u00e9seau (PCC), puis s\u00e9parez les donn\u00e9es relatives aux d\u00e9rivations de celles concernant l'ensemble du site.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Utilisez la m\u00eame plage horaire de 15 ou 30 minutes pour le calcul de la demande, le bilan \u00e9nerg\u00e9tique CA du syst\u00e8me BESS et le mod\u00e8le de retour sur investissement.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Pr\u00e9cisez les contraintes techniques, la logique de commande et les crit\u00e8res de r\u00e9ception dans l'appel d'offres avant de choisir une armoire.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-094b7550 auto-image elementor-widget elementor-widget-image\" data-id=\"094b7550\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"768\" height=\"768\" src=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/bess-motor-starting-hero.jpg\" class=\"attachment-1536x1536 size-1536x1536 wp-image-4821\" alt=\"Armoire BESS d&#039;ext\u00e9rieur MegSolid, armoire de commande PCS et moteur industriel d&#039;extrudeuse dans une usine de recyclage\" srcset=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/bess-motor-starting-hero.jpg 768w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/bess-motor-starting-hero-300x300.jpg 300w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/bess-motor-starting-hero-150x150.jpg 150w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/bess-motor-starting-hero-600x600.jpg 600w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/bess-motor-starting-hero-100x100.jpg 100w\" sizes=\"(max-width: 768px) 100vw, 768px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c39a0e0f auto-h2 elementor-widget elementor-widget-heading\" data-id=\"c39a0e0f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Commencez par l'\u00e9v\u00e9nement du PCC, et non par la composition du gouvernement<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-22130b73 auto-p elementor-widget elementor-widget-heading\" data-id=\"22130b73\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Un moteur peut absorber un courant \u00e9lev\u00e9 pendant quelques secondes seulement, mais les cons\u00e9quences op\u00e9rationnelles peuvent \u00eatre graves si la tension du r\u00e9seau de distribution (PCC) chute et qu'un automate programmable (PLC), un variateur de vitesse ou un contacteur se d\u00e9sactive. Le premier dossier de mesures doit inclure les sch\u00e9mas unifilaires, l\u2019imp\u00e9dance du transformateur, les r\u00e9glages de protection, les donn\u00e9es figurant sur la plaque signal\u00e9tique du moteur, la m\u00e9thode de d\u00e9marrage, les courbes enregistr\u00e9es par l\u2019oscilloscope ou l\u2019analyseur de puissance, ainsi que la tension au point de connexion commun (PCC), la puissance en kW, la puissance r\u00e9active en kVAr et la puissance apparente en kVA, le tout align\u00e9 dans le temps. Les calculs pertinents et les limites de contr\u00f4le doivent figurer dans le <strong><a href=\"https:\/\/www.solidess.com\/fr\/ingenierie-des-onduleurs-pcs\/\" target=\"_blank\" style=\"color:#61ce70\">Analyse technique des PCS et des onduleurs<\/a><\/strong>, et non dans une estimation g\u00e9n\u00e9rique de la capacit\u00e9 de la batterie.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a3cd3545 auto-p elementor-widget elementor-widget-heading\" data-id=\"a3cd3545\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Il convient ici de bien distinguer deux aspects importants. Le calcul de la puissance des boucles d'alimentation permet de comprendre le fonctionnement du d\u00e9marrage du moteur. Les valeurs PCC totales d\u00e9terminent l'exposition \u00e0 la demande du r\u00e9seau. La combinaison de la puissance en kW des boucles d'alimentation et de la consommation en kWh de l'ensemble du site conduit \u00e0 un mod\u00e8le de retour sur investissement erron\u00e9. Veillez \u00e0 indiquer clairement ces deux points de mesure sur chaque fiche de test.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-cd35f0fe auto-h2 elementor-widget elementor-widget-heading\" data-id=\"cd35f0fe\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">D\u00e9terminez si la contrainte concerne l'appui transitoire ou l'\u00e9nergie par intervalle de demande<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-95176a14 auto-p elementor-widget elementor-widget-heading\" data-id=\"95176a14\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Un d\u00e9marrage en ligne directe peut durer de 3 \u00e0 10 secondes. Un compteur tarifaire \u00e9value normalement un intervalle beaucoup plus long. Un bref pic de 182 kVA n'a en soi que peu d'effet sur une moyenne sur 30 minutes, mais des d\u00e9marrages fr\u00e9quents, une courbe d'acc\u00e9l\u00e9ration lente ou une charge de processus soutenue peuvent augmenter de mani\u00e8re significative la demande sur cet intervalle. C'est pourquoi un projet ne doit pas pr\u00e9tendre r\u00e9aliser des \u00e9conomies sur la redevance de puissance uniquement gr\u00e2ce aux courants d'appel des moteurs.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-aaee096d auto-image elementor-widget elementor-widget-image\" data-id=\"aaee096d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"1200\" height=\"900\" src=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/bess-motor-starting-transient-vs-demand.jpg\" class=\"attachment-1536x1536 size-1536x1536 wp-image-4823\" alt=\"Tableau d&#039;aide \u00e0 la d\u00e9cision comparant une chute de tension au d\u00e9marrage du moteur d&#039;une dur\u00e9e de 3 \u00e0 10 secondes \u00e0 un intervalle de demande de 15 ou 30 minutes\" srcset=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/bess-motor-starting-transient-vs-demand.jpg 1200w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/bess-motor-starting-transient-vs-demand-300x225.jpg 300w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/bess-motor-starting-transient-vs-demand-1024x768.jpg 1024w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/bess-motor-starting-transient-vs-demand-768x576.jpg 768w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/bess-motor-starting-transient-vs-demand-600x450.jpg 600w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5830aa7e auto-table elementor-widget elementor-widget-text-editor\" data-id=\"5830aa7e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"cea-table-wrap\"><table><thead><tr><th>Si l'acheteur constate que<\/th><th>Question d'ing\u00e9nierie fondamentale<\/th><th>Quelles sont les dimensions de la solution ?<\/th><th>Justificatifs requis<\/th><\/tr><\/thead><tbody><tr><td>R\u00e9initialisations de l'automate programmable ou d\u00e9clenchement des contacteurs lors des d\u00e9marrages<\/td><td>Le PCS est-il capable de fournir P et Q dans les limites de sa puissance active et de sa puissance apparente ?<\/td><td>PCS kVA, marge P-Q, imp\u00e9dance du transformateur, m\u00e9thode de d\u00e9marrage et coordination des protections<\/td><td>Trace haute r\u00e9solution de la tension et du courant du PCC ; s\u00e9quence de commande et de d\u00e9clenchement valid\u00e9e<\/td><\/tr><tr><td>Demande maximale sur 15 ou 30 minutes<\/td><td>Quelle quantit\u00e9 d'\u00e9nergie doit \u00eatre transf\u00e9r\u00e9e au cours de la p\u00e9riode de facturation ?<\/td><td>kWh disponibles du syst\u00e8me de stockage d'\u00e9nergie par batterie (BESS), kW de d\u00e9charge, plage de recharge et intervalle tarifaire<\/td><td>Donn\u00e9es du compteur \u00e0 relev\u00e9 p\u00e9riodique, facture, r\u00e8gles tarifaires et bilan \u00e9nerg\u00e9tique PCC mesur\u00e9<\/td><\/tr><tr><td>Ces deux probl\u00e8mes<\/td><td>Un seul programme d'exploitation permet-il de pr\u00e9server la marge de man\u0153uvre du PCS et la r\u00e9serve d'\u00e9nergie ?<\/td><td>La plus stricte des contraintes transitoires et d'intervalle<\/td><td>Un test SAT combin\u00e9 avec des paliers de charge, une r\u00e9serve SOC et des conditions de production reproductibles<\/td><\/tr><\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e0a8d530 auto-p elementor-widget elementor-widget-heading\" data-id=\"e0a8d530\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Pour une installation existante de 400 V, l'\u00e9tude relative au raccordement et \u00e0 la protection du tableau \u00e9lectrique fait partie int\u00e9grante de la d\u00e9cision et ne rel\u00e8ve pas des formalit\u00e9s administratives li\u00e9es \u00e0 l'installation. Consultez le <strong><a href=\"https:\/\/www.solidess.com\/fr\/connexion-de-batterie-400-v-au-tableau-electrique-existant\/\" target=\"_blank\" style=\"color:#61ce70\">Guide de raccordement d'un syst\u00e8me de stockage d'\u00e9nergie (BESS) de 400 V aux tableaux \u00e9lectriques existants<\/a><\/strong> avec l'EPC et l'ing\u00e9nieur charg\u00e9 de la protection avant de fixer le point de raccordement.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d6607bfe elementor-tablet-align-center elementor-align-center auto-cta elementor-widget elementor-widget-button\" data-id=\"d6607bfe\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"#elementor-action%3Aaction%3Dpopup%3Aopen%26settings%3DeyJpZCI6Ijk0OCIsInRvZ2dsZSI6ZmFsc2V9\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Envoyez vos donn\u00e9es relatives au d\u00e9marrage du moteur et au PCC pour un examen PCS<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-002737c3 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"002737c3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Dimensionnement des PCS : v\u00e9rifier la marge disponible en kVA et en P-Q avant de garantir un soutien de tension<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5fb8335a auto-p elementor-widget elementor-widget-heading\" data-id=\"5fb8335a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Une puissance nominale de 100 kW correspond \u00e0 la puissance active ; les probl\u00e8mes de d\u00e9marrage des moteurs sont souvent limit\u00e9s par la puissance apparente et le courant. La relation applicable est la suivante : S = \u221a(P\u00b2 + Q\u00b2). Si la puissance active d\u00e9livr\u00e9e est d\u00e9j\u00e0 proche de la limite du PCS, il peut ne rester qu\u2019une faible marge de puissance apparente pour le soutien r\u00e9actif. \u00c0 l\u2019inverse, un PCS peut disposer d\u2019une marge en kVA tout en restant limit\u00e9 par le courant, la tension continue ou les seuils de protection.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-95096194 auto-p elementor-widget elementor-widget-heading\" data-id=\"95096194\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Pour ce SAT, le PCS a \u00e9t\u00e9 configur\u00e9 avec un <strong>strat\u00e9gie de r\u00e9gulation \u00ab active-power-priority \u00bb (priorit\u00e9 P)<\/strong>. Il s'agit d'une configuration de projet, et non d'une affirmation concernant tous les param\u00e8tres par d\u00e9faut du MegSolid PCS. Lorsque l'interface coordonn\u00e9e entre l'automate programmable (PLC) et le syst\u00e8me de contr\u00f4le de processus (PCS) dispose d'un signal valid\u00e9 autorisant le d\u00e9marrage ou d'un signal \u00e0 contact sec, un syst\u00e8me de gestion d'urgence (EMS) peut pr\u00e9-positionner une consigne de sortie avant le d\u00e9marrage. La mise en service doit permettre de v\u00e9rifier la synchronisation, les verrouillages, le fonctionnement de secours et la coordination des protections. Le <strong><a href=\"https:\/\/www.solidess.com\/fr\/product\/systeme-de-conversion-denergie-megsolid\/\" target=\"_blank\" style=\"color:#61ce70\">Syst\u00e8me de conversion d'\u00e9nergie MegSolid<\/a><\/strong> Cette page correspond \u00e0 la r\u00e9f\u00e9rence du produit ; la fiche technique du projet approuv\u00e9e et le proc\u00e8s-verbal d'essai restent la source de r\u00e9f\u00e9rence pour les limites de contr\u00f4le d\u00e9finies pour l'installation.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-95963596 auto-table elementor-widget elementor-widget-text-editor\" data-id=\"95963596\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"cea-table-wrap\"><table><thead><tr><th>Point de mesure au niveau de l'\u00e9v\u00e9nement<\/th><th>P (kW)<\/th><th>Q (kVAr)<\/th><th>S (kVA)<\/th><th>VLL (V)<\/th><\/tr><\/thead><tbody><tr><td>Charge du motor\u00e9ducteur lors du d\u00e9marrage enregistr\u00e9<\/td><td>145<\/td><td>+115<\/td><td>185<\/td><td>360<\/td><\/tr><tr><td>Puissance de sortie du BESS mesur\u00e9e au niveau du PCS<\/td><td>90<\/td><td>-30<\/td><td>95<\/td><td>\u2013<\/td><\/tr><tr><td>Contribution r\u00e9siduelle de la ligne d'alimentation apr\u00e8s la r\u00e9ponse du syst\u00e8me de stockage d'\u00e9nergie par batterie (BESS)<\/td><td>55<\/td><td>+85<\/td><td>101<\/td><td>385<\/td><\/tr><\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-70ed7a91 auto-p elementor-widget elementor-widget-heading\" data-id=\"70ed7a91\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Ce tableau pr\u00e9sente une explication au niveau de l'\u00e9v\u00e9nement pour une ligne d'alimentation et ne correspond pas \u00e0 un chiffre global d'importation du site. Un Q positif indique une puissance r\u00e9active en retard absorb\u00e9e du r\u00e9seau ; la valeur BESS enregistr\u00e9e correspond \u00e0 un Q en avance. Il s'agit d'une observation issue d'un test du projet et elle ne doit pas \u00eatre extrapol\u00e9e \u00e0 un autre transformateur, d\u00e9marreur de moteur ou ligne d'alimentation sans nouvelles mesures.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-47f38c63 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"47f38c63\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Pourquoi le mod\u00e8le ESSA0100B-0215 constitue un point de d\u00e9part pour cette mission<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-84c123ca auto-p elementor-widget elementor-widget-heading\" data-id=\"84c123ca\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">La recommandation figurant dans ce guide se limite \u00e0 une seule configuration publi\u00e9e : ESSA0100B-0215. MegSolid indique une capacit\u00e9 nominale de 215,04 kWh, une puissance nominale en courant alternatif de 100 kW, un syst\u00e8me de batteries de 768 V, une plage de fonctionnement de 672 \u00e0 850 V, un taux de charge\/d\u00e9charge nominal de 0,5 C \u00e0 25 \u00b0C, un indice de protection IP54 et une dur\u00e9e de vie annonc\u00e9e d\u2019au moins 5 000 cycles. L\u2019armoire est un produit LFP tout-en-un C&amp;I con\u00e7u pour une installation en ext\u00e9rieur. Ces caract\u00e9ristiques publi\u00e9es en font une solution pertinente lorsque la puissance requise est proche de 100 kW et que le mod\u00e8le d\u2019intervalle r\u00e9pond aux exigences en mati\u00e8re d\u2019\u00e9nergie utilisable.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-31b17eb4 auto-p elementor-widget elementor-widget-heading\" data-id=\"31b17eb4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">ESSA0100B-0215 brings battery, conversion and control functions into one defined outdoor cabinet platform, reducing the equipment interfaces your EPC has to reconcile for this class of project. Buy it when the measured duty fits the 100 kW AC rating and the available usable energy. Its 215.04 kWh nominal capacity still needs allowances for SOC reserve, conversion loss, auxiliaries, temperature, ageing, BMS limits and the recharge window. If the start requires more PCS kVA or current headroom, price the appropriate converter configuration instead of borrowing a different model's figures to make this cabinet appear larger.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2bcd026f auto-table elementor-widget elementor-widget-text-editor\" data-id=\"2bcd026f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"cea-table-wrap\"><table><thead><tr><th>Question de l'acheteur<\/th><th>Pourquoi ce mod\u00e8le ESSA pourrait convenir<\/th><th>Ce qui doit encore faire l'objet d'une validation du projet<\/th><\/tr><\/thead><tbody><tr><td>Est-ce que cela permet de r\u00e9duire un pic de demande de l'ordre de 100 kW ?<\/td><td>La puissance nominale en courant alternatif indiqu\u00e9e est de 100 kW.<\/td><td>Forme de la cr\u00eate du PCC, SOC de r\u00e9serve, dur\u00e9e de l'intervalle et temps de recharge.<\/td><\/tr><tr><td>Est-ce qu'il peut prendre en charge l'\u00e9v\u00e9nement moteur enregistr\u00e9 ?<\/td><td>Le Conseil des ministres soumet \u00e0 examen la plateforme \u00ab BESS \u00bb consacr\u00e9e \u00e0 l'\u00e9lectricit\u00e9 et \u00e0 l'\u00e9nergie.<\/td><td>Limites de puissance et de courant du PCS, diagramme P-Q, courbes de fonctionnement du transformateur et de d\u00e9marrage du moteur.<\/td><\/tr><tr><td>Peut-on l'installer \u00e0 l'ext\u00e9rieur ?<\/td><td>L'indice de protection indiqu\u00e9 est IP54.<\/td><td>Fondations, conditions environnementales, d\u00e9gagements, drainage, plan d'\u00e9vacuation en cas d'incendie et exigences des autorit\u00e9s locales.<\/td><\/tr><\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-413fe7f6 auto-p elementor-widget elementor-widget-heading\" data-id=\"413fe7f6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">L'EMS doit mettre \u00e0 disposition les signaux utilis\u00e9s pour d\u00e9montrer cette fonction. L'EPC doit demander les <strong><a href=\"https:\/\/www.solidess.com\/fr\/liste-des-points-scada-bess-ce-que-votre-ems-doit-envoyer\/\" target=\"_blank\" style=\"color:#61ce70\">Liste des points SCADA BESS<\/a><\/strong> d\u00e8s le d\u00e9but, notamment la puissance du PCC, les commandes P-Q du PCS et le retour d'information, le SOC, les temp\u00e9ratures, les alarmes, le mode de fonctionnement et les \u00e9tats de protection.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1f0e0f96 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"1f0e0f96\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Construire le mod\u00e8le de retour sur investissement \u00e0 partir d'un intervalle de demande complet<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3eec60fb auto-p elementor-widget elementor-widget-heading\" data-id=\"3eec60fb\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Le projet SAT, men\u00e9 dans une usine de recyclage de plastiques dont l'identit\u00e9 n'est pas divulgu\u00e9e, situ\u00e9e \u00e0 East London, en Afrique du Sud, a utilis\u00e9 deux s\u00e9quences de fonctionnement de 10 minutes chacune et une p\u00e9riode d'inactivit\u00e9 combin\u00e9e de 10 minutes au sein d'une fen\u00eatre de 30 minutes. L'extrudeuse de 132 kW pouvait effectuer jusqu'\u00e0 10 cycles par heure en conditions de production normales. Ce mod\u00e8le est utile car il mesure le m\u00eame intervalle que celui que la logique tarifaire doit \u00e9valuer. Il ne s'agit pas d'une affirmation concernant l'ensemble des tarifs ou des usines sud-africaines.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b87cd3b1 auto-image elementor-widget elementor-widget-image\" data-id=\"b87cd3b1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"1200\" height=\"900\" src=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/bess-motor-starting-sat-roi-evidence.jpg\" class=\"attachment-1536x1536 size-1536x1536 wp-image-4822\" alt=\"Sch\u00e9ma d&#039;un test PCC de 30 minutes, bilan \u00e9nerg\u00e9tique CA, perte de SOC et donn\u00e9es SAT pour le d\u00e9marrage du moteur BESS et la r\u00e9gulation de la demande\" srcset=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/bess-motor-starting-sat-roi-evidence.jpg 1200w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/bess-motor-starting-sat-roi-evidence-300x225.jpg 300w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/bess-motor-starting-sat-roi-evidence-1024x768.jpg 1024w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/bess-motor-starting-sat-roi-evidence-768x576.jpg 768w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/08\/bess-motor-starting-sat-roi-evidence-600x450.jpg 600w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-31a16c95 auto-p elementor-widget elementor-widget-heading\" data-id=\"31a16c95\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Sans le BESS, l'\u00e9nergie totale du PCC au cours de l'essai de 30 minutes s'\u00e9levait \u00e0 80 kWh, soit une demande moyenne de 160 kW. Avec le BESS, l'\u00e9nergie pr\u00e9lev\u00e9e sur le r\u00e9seau s'\u00e9levait \u00e0 55 kWh, soit une demande moyenne de 110 kW. Le BESS a fourni 25 kWh nets c\u00f4t\u00e9 courant alternatif pendant cet intervalle. La r\u00e9duction r\u00e9elle de l'\u00e9tat de charge (SOC) de la batterie \u00e9tait sup\u00e9rieure \u00e0 25 kWh apr\u00e8s conversion et pertes auxiliaires. Il s'agit l\u00e0 de la limite correcte pour le bilan \u00e9nerg\u00e9tique : il ne faut pas consid\u00e9rer l'alimentation nette en courant alternatif comme une d\u00e9charge de la batterie.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6752c2e0 auto-p elementor-widget elementor-widget-heading\" data-id=\"6752c2e0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Pour prendre une d\u00e9cision d'investissement, r\u00e9p\u00e9tez ce test dans des conditions repr\u00e9sentatives de production, d'environnement et de tarification. Calculez ensuite les \u00e9conomies de puissance \u00e0 partir de la r\u00e8gle de comptage applicable, et pas uniquement \u00e0 partir de la r\u00e9duction en kWh. Si le tarif facture la puissance en kVA, calculez chaque intervalle factur\u00e9 \u00e0 partir du kVA mesur\u00e9 au point de raccordement (PCC) et du facteur de puissance. Pour le mod\u00e8le financier, combinez les donn\u00e9es d\u2019intervalle v\u00e9rifi\u00e9es avec le co\u00fbt total d\u2019installation, le co\u00fbt d\u2019exploitation annuel, les hypoth\u00e8ses de d\u00e9gradation, les hypoth\u00e8ses de disponibilit\u00e9 et la valeur du risque r\u00e9siduel. Le <strong><a href=\"https:\/\/www.solidess.com\/fr\/maximiser-le-retour-sur-investissement-de-lecretage-des-pointes-pour-les-secteurs-commercial-et-industriel\/\" target=\"_blank\" style=\"color:#61ce70\">Guide sur la zone d'int\u00e9r\u00eat (ROI) pour l'aplanissement des pics C&amp;I<\/a><\/strong> offre un cadre utile pour garder ces hypoth\u00e8ses bien en vue.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-473f392d elementor-tablet-align-center elementor-align-center auto-cta elementor-widget elementor-widget-button\" data-id=\"473f392d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"#elementor-action%3Aaction%3Dpopup%3Aopen%26settings%3DeyJpZCI6Ijk0OCIsInRvZ2dsZSI6ZmFsc2V9\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Demander un ESSA0100B-0215 et un r\u00e9examen des obligations li\u00e9es au PCS<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-54a4d02f auto-h2 elementor-widget elementor-widget-heading\" data-id=\"54a4d02f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Utiliser les \u00e9l\u00e9ments de preuve du SAT pour distinguer un syst\u00e8me fonctionnel d'un calcul qui semble correct<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2512eaaf auto-p elementor-widget elementor-widget-heading\" data-id=\"2512eaaf\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Pour qu\u2019un test SAT soit fiable, il ne suffit pas d\u2019une simple capture d\u2019\u00e9cran des valeurs de cr\u00eate. Il faut enregistrer de mani\u00e8re synchronis\u00e9e les valeurs de puissance (kW et kVA) du PCC, la tension, la puissance CA du BESS, la r\u00e9ponse P-Q du PCS, le SOC, la temp\u00e9rature, les alarmes ainsi que l\u2019\u00e9tat de toute entr\u00e9e autorisant le d\u00e9marrage. R\u00e9p\u00e9tez l\u2019\u00e9v\u00e9nement requis dans des conditions contr\u00f4l\u00e9es, identifiez les limites de mesure et conservez les fichiers bruts. Un r\u00e9sultat conforme \u00e0 un seul \u00e9tat de charge ou \u00e0 une seule condition ambiante ne suffit pas \u00e0 prouver la conformit\u00e9 au cycle de fonctionnement quotidien.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b09a449a auto-p elementor-widget elementor-widget-heading\" data-id=\"b09a449a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Le rapport de d\u00e9bogage interne correspondant \u00e0 cet exemple, #ZA-2024-119, fait \u00e9tat d\u2019une demande moyenne de 110 kW sur 30 minutes et d\u2019un \u00e9cart de temp\u00e9rature du rack de 3,2 \u00b0C \u00e0 une temp\u00e9rature ambiante de 28 \u00b0C au cours de l\u2019essai mentionn\u00e9. Le profil de charge et le calendrier du client sont anonymis\u00e9s en vertu d\u2019un accord de confidentialit\u00e9 (NDA). Ces valeurs sont fournies \u00e0 titre indicatif uniquement ; les performances r\u00e9elles varient en fonction de la programmation du syst\u00e8me de gestion de l\u2019\u00e9nergie (EMS), de l\u2019imp\u00e9dance du transformateur, des conditions ambiantes, des limites des batteries et de la s\u00e9quence de production. Pour un plan de test rigoureux, utilisez le <strong><a href=\"https:\/\/www.solidess.com\/fr\/pourquoi-un-bess-echoue-a-son-test-de-capacite-sans-declencher-dalarme\/\" target=\"_blank\" style=\"color:#61ce70\">Liste de contr\u00f4le pour le test de capacit\u00e9 du BESS<\/a><\/strong> ainsi que la fiche de r\u00e9ception du d\u00e9marreur.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d0ae275f auto-h2 elementor-widget elementor-widget-heading\" data-id=\"d0ae275f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Les r\u00e9clamations relatives \u00e0 la s\u00e9curit\u00e9 thermique et aux harmoniques doivent s'appuyer sur des \u00e9l\u00e9ments de preuve sp\u00e9cifiques<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9c69a635 auto-p elementor-widget elementor-widget-heading\" data-id=\"9c69a635\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Il ne faut pas interpr\u00e9ter un indice de protection IP, une d\u00e9claration relative \u00e0 la composition chimique d\u2019un LFP ou une r\u00e9f\u00e9rence \u00e0 un syst\u00e8me d\u2019extinction d\u2019incendie comme une garantie que l\u2019emballement thermique ne peut pas se produire. L\u2019acheteur doit exiger la nomenclature exacte du produit command\u00e9, les limites du syst\u00e8me de gestion de la batterie (BMS), la conception du syst\u00e8me de refroidissement, les d\u00e9tails relatifs \u00e0 la d\u00e9tection et \u00e0 l\u2019extinction, la matrice de cause \u00e0 effet, le sch\u00e9ma d\u2019installation, le plan d\u2019isolation d\u2019urgence et les limites SAT. La fiche technique ESSA mentionne les options d\u2019extinction par a\u00e9rosol ou NOVEC1230 ; l\u2019agent utilis\u00e9, le dispositif de d\u00e9tection et les exigences d\u2019homologation locales doivent \u00eatre confirm\u00e9s pour la configuration achet\u00e9e.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b2015aa7 auto-p elementor-widget elementor-widget-heading\" data-id=\"b2015aa7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">La norme UL 9540A est une m\u00e9thode d'essai destin\u00e9e \u00e0 \u00e9valuer la propagation d'un incendie d\u00fb \u00e0 un emballement thermique ; elle ne constitue pas une homologation g\u00e9n\u00e9rale pour l'installation. La norme UL 9540 traite de la s\u00e9curit\u00e9 des syst\u00e8mes de stockage d\u2019\u00e9nergie, la norme CEI 62619 traite des exigences de s\u00e9curit\u00e9 relatives aux batteries industrielles, et la norme NFPA 855 peut s\u2019appliquer lorsqu\u2019elle est adopt\u00e9e par l\u2019autorit\u00e9 comp\u00e9tente. Il convient de se r\u00e9f\u00e9rer \u00e0 la juridiction, \u00e0 l\u2019\u00e9dition et \u00e0 la configuration du site applicables, plut\u00f4t que de consid\u00e9rer ces normes comme interchangeables. Voir le <strong><a href=\"https:\/\/www.solidess.com\/fr\/guide-de-lepc-sur-la-conformite-aux-normes-ul-9540a-et-cei-62619\/\" target=\"_blank\" style=\"color:#61ce70\">Guide EPC selon les normes UL 9540A et CEI 62619<\/a><\/strong> et le <strong><a href=\"https:\/\/www.solidess.com\/fr\/prevent-bess-thermal-runaway\/\" target=\"_blank\" style=\"color:#61ce70\">Guide de pr\u00e9vention de l'emballement thermique<\/a><\/strong> avant de finaliser le plan de lutte contre les incendies.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8792496f auto-p elementor-widget elementor-widget-heading\" data-id=\"8792496f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Les performances harmoniques exigent la m\u00eame rigueur. La mesure SAT a donn\u00e9 un THDi de 2,11 TP5T au point de connexion du r\u00e9seau (PCC) dans les conditions de fonctionnement du moteur indiqu\u00e9es, contre 6,81 TP5T dans la r\u00e9f\u00e9rence enregistr\u00e9e. Il ne s\u2019agit pas d\u2019une d\u00e9claration de conformit\u00e9 universelle \u00e0 la norme IEEE 519. Une \u00e9valuation finale doit s'appuyer sur le PCC, les limites applicables du r\u00e9seau de distribution et le rapport Isc\/IL sp\u00e9cifique au site pour \u00e9valuer le TDD.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e15449b5 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"e15449b5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Documents \u00e0 fournir avant de demander une proposition BESS et PCS<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9d257aeb elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"9d257aeb\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Douze mois de factures de services publics, ainsi que les r\u00e8gles applicables en mati\u00e8re de frais de puissance et de p\u00e9riode de facturation.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Au moins deux semaines de donn\u00e9es PCC de 1, 5, 15 ou 30 minutes, ainsi que des trac\u00e9s haute r\u00e9solution correspondant \u00e0 l'\u00e9v\u00e9nement moteur.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Sch\u00e9ma unifilaire, plaque signal\u00e9tique et imp\u00e9dance du transformateur, caract\u00e9ristiques nominales du tableau de distribution, r\u00e9glages de protection et caract\u00e9ristiques du g\u00e9n\u00e9rateur.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Plaque signal\u00e9tique du moteur, m\u00e9thode de d\u00e9marrage, courbe d'acc\u00e9l\u00e9ration, fr\u00e9quence de d\u00e9marrage et interruption de production autoris\u00e9e.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Tension cible requise, demande maximale cible, niveau de charge (SOC) r\u00e9serv\u00e9, cycle de service quotidien et dur\u00e9e de vie cible.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Plage de temp\u00e9rature ambiante du site, am\u00e9nagement civil, d\u00e9gagements, plan de s\u00e9curit\u00e9 incendie, architecture des communications et justificatifs SAT requis.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-59afaf9b auto-p elementor-widget elementor-widget-heading\" data-id=\"59afaf9b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Send MegSolid the motor-start trace, tariff interval and loads that must continue through the event to obtain an ESSA0100B-0215 or separately sized PCS-and-battery proposal. Keep the power support and demand-interval energy in the same operating schedule so you pay for equipment the plant can use. If a generator is also involved, define the grid-forming source, charge permissions, reverse-power protection, CT direction and fallback mode before commissioning; the <strong><a href=\"https:\/\/www.solidess.com\/fr\/controle-de-bess-et-de-groupe-electrogene-diesel-sans-declenchements-sur-puissance-inverse\/\" target=\"_blank\" style=\"color:#61ce70\">Guide de commande du BESS et du groupe \u00e9lectrog\u00e8ne diesel<\/a><\/strong> covers those control questions.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-50ef58a1 elementor-tablet-align-center elementor-align-center auto-cta elementor-widget elementor-widget-button\" data-id=\"50ef58a1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"#elementor-action%3Aaction%3Dpopup%3Aopen%26settings%3DeyJpZCI6Ijk0OCIsInRvZ2dsZSI6ZmFsc2V9\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Analyse des donn\u00e9es d'entr\u00e9e du SAT et du mod\u00e8le de retour sur investissement \u00ab Demand-Interval \u00bb<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-19d7d9f4 auto-faq e-flex e-con-boxed e-con e-child\" data-id=\"19d7d9f4\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-b4abc6df elementor-widget elementor-widget-heading\" data-id=\"b4abc6df\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">FAQ<\/h2>\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-a258e55b e-con-full e-flex e-con e-child\" data-id=\"a258e55b\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-2c83de3c elementor-widget elementor-widget-n-accordion\" data-id=\"2c83de3c\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;default_state&quot;:&quot;all_collapsed&quot;,&quot;max_items_expended&quot;:&quot;one&quot;,&quot;n_accordion_animation_duration&quot;:{&quot;unit&quot;:&quot;ms&quot;,&quot;size&quot;:400,&quot;sizes&quot;:[]}}\" data-widget_type=\"nested-accordion.default\">\n\t\t\t\t\t\t\t<div class=\"e-n-accordion\" aria-label=\"Accord\u00e9on. Ouvrez les liens \u00e0 l&#039;aide de la touche Entr\u00e9e ou de la barre d&#039;espace, fermez-les avec la touche \u00c9chap et naviguez \u00e0 l&#039;aide des touches fl\u00e9ch\u00e9es.\">\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-7460\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"1\" tabindex=\"0\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-7460\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Un syst\u00e8me de stockage d'\u00e9nergie par batterie (BESS) peut-il d\u00e9marrer un moteur industriel de 132 kW ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-7460\" class=\"elementor-element elementor-element-b081d7ae e-con-full e-flex e-con e-child\" data-id=\"b081d7ae\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-7460\" class=\"elementor-element elementor-element-201b9985 e-con-full e-flex e-con e-child\" data-id=\"201b9985\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ff86e9c3 elementor-widget elementor-widget-heading\" data-id=\"ff86e9c3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">C'est possible, mais la plaque signal\u00e9tique du moteur ne suffit pas. V\u00e9rifiez le type de d\u00e9marreur, la courbe d'acc\u00e9l\u00e9ration, l'imp\u00e9dance du transformateur, la chute de tension sur la ligne d'alimentation, la limite de kVA\/courant du PCS, les limites de courant continu et la coordination des protections au point de raccordement r\u00e9el.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-7461\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"2\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-7461\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Le courant d'appel d'un moteur entra\u00eene-t-il automatiquement un probl\u00e8me li\u00e9 \u00e0 la redevance de puissance ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-7461\" class=\"elementor-element elementor-element-3608c455 e-con-full e-flex e-con e-child\" data-id=\"3608c455\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-7461\" class=\"elementor-element elementor-element-fed4a81e e-con-full e-flex e-con e-child\" data-id=\"fed4a81e\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-5f578354 elementor-widget elementor-widget-heading\" data-id=\"5f578354\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Non. Un pic de courant de d\u00e9marrage de courte dur\u00e9e peut entra\u00eener un probl\u00e8me de qualit\u00e9 de tension sans pour autant modifier de mani\u00e8re significative un intervalle de demande de 15 ou 30 minutes. Seules les donn\u00e9es mesur\u00e9es par intervalle et la r\u00e8gle tarifaire applicable permettent de quantifier l'exposition de la demande.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-7462\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"3\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-7462\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Pourquoi les valeurs \u00ab kVA \u00bb du PCS et \u00ab kWh \u00bb du BESS sont-elles v\u00e9rifi\u00e9es s\u00e9par\u00e9ment ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-7462\" class=\"elementor-element elementor-element-0e994921 e-con-full e-flex e-con e-child\" data-id=\"0e994921\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-7462\" class=\"elementor-element elementor-element-f1682fc5 e-con-full e-flex e-con e-child\" data-id=\"f1682fc5\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-763968b9 elementor-widget elementor-widget-heading\" data-id=\"763968b9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">La puissance PCS en kVA et la marge P-Q d\u00e9terminent si le syst\u00e8me est capable de faire face \u00e0 un incident \u00e9lectrique de courte dur\u00e9e. La capacit\u00e9 utile du syst\u00e8me de stockage d'\u00e9nergie par batterie (BESS) en kWh et son temps de recharge d\u00e9terminent s'il est en mesure d'assurer la fonction de lissage de la demande requise pendant la p\u00e9riode de facturation.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-7463\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"4\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-7463\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Quel produit est utilis\u00e9 dans ce guide ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-7463\" class=\"elementor-element elementor-element-17409371 e-con-full e-flex e-con e-child\" data-id=\"17409371\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-7463\" class=\"elementor-element elementor-element-fb81990f e-con-full e-flex e-con e-child\" data-id=\"fb81990f\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-e6bfccbc elementor-widget elementor-widget-heading\" data-id=\"e6bfccbc\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">L'armoire \u00e9valu\u00e9e est le mod\u00e8le MegSolid ESSA0100B-0215, dont la puissance nominale en courant alternatif est de 100 kW et la capacit\u00e9 nominale de 215,04 kWh. La pertinence finale d\u00e9pendra toutefois d'une \u00e9tude sp\u00e9cifique au site portant sur le syst\u00e8me de conversion de puissance (PCS), le moteur et les intervalles de demande.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-7464\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"5\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-7464\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Pourquoi recommander le mod\u00e8le ESSA0100B-0215 pour cette application ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-7464\" class=\"elementor-element elementor-element-f2d5dd6b e-con-full e-flex e-con e-child\" data-id=\"f2d5dd6b\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-7464\" class=\"elementor-element elementor-element-49876ba5 e-con-full e-flex e-con e-child\" data-id=\"49876ba5\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-442326cb elementor-widget elementor-widget-heading\" data-id=\"442326cb\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Il s'agit d'une r\u00e9f\u00e9rence coh\u00e9rente d'armoire C&amp;I d'ext\u00e9rieur de la classe des 100 kW, accompagn\u00e9e d'un cahier des charges document\u00e9. Elle ne doit \u00eatre retenue dans la pr\u00e9s\u00e9lection que si la puissance requise, l'\u00e9nergie utilisable, les conditions ambiantes et les commandes correspondent aux conditions d'exploitation v\u00e9rifi\u00e9es du projet.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-7465\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"6\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-7465\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Est-ce que 215,04 kWh correspondent \u00e0 215,04 kWh d'\u00e9nergie CA utilisable ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-7465\" class=\"elementor-element elementor-element-a0900434 e-con-full e-flex e-con e-child\" data-id=\"a0900434\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-7465\" class=\"elementor-element elementor-element-6f9bf824 e-con-full e-flex e-con e-child\" data-id=\"6f9bf824\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-8e9c455b elementor-widget elementor-widget-heading\" data-id=\"8e9c455b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Non. L'\u00e9nergie nominale de la batterie ne correspond pas \u00e0 l'\u00e9nergie CA fournie. Le niveau de charge (SOC) de r\u00e9serve, les pertes de conversion, la consommation des \u00e9quipements auxiliaires, la temp\u00e9rature, le vieillissement, les limites du BMS et la planification des recharges sont autant de facteurs qui influent sur l'\u00e9nergie utilisable.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-7466\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"7\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-7466\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Un seul syst\u00e8me de stockage d'\u00e9nergie par batterie (BESS) peut-il \u00e0 la fois assurer le maintien de la tension et permettre l'\u00e9cr\u00eatement des pics de consommation ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-7466\" class=\"elementor-element elementor-element-379e1821 e-con-full e-flex e-con e-child\" data-id=\"379e1821\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-7466\" class=\"elementor-element elementor-element-44e283f3 e-con-full e-flex e-con e-child\" data-id=\"44e283f3\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-e3069b34 elementor-widget elementor-widget-heading\" data-id=\"e3069b34\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Oui, \u00e0 condition que le PCS dispose de la marge P-Q\/courant n\u00e9cessaire et que l'EMS conserve suffisamment d'\u00e9nergie et de r\u00e9serve de SOC pour les deux fonctions. Cela doit \u00eatre v\u00e9rifi\u00e9 par rapport au programme d'exploitation combin\u00e9.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-7467\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"8\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-7467\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Que signifie \u00ab contr\u00f4le prioritaire de la puissance active \u00bb dans ce SAT ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-7467\" class=\"elementor-element elementor-element-cda31345 e-con-full e-flex e-con e-child\" data-id=\"cda31345\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-7467\" class=\"elementor-element elementor-element-7b6b5758 e-con-full e-flex e-con e-child\" data-id=\"7b6b5758\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-add3e563 elementor-widget elementor-widget-heading\" data-id=\"add3e563\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Pour le SAT enregistr\u00e9, le PCS a \u00e9t\u00e9 configur\u00e9 de mani\u00e8re \u00e0 donner la priorit\u00e9 \u00e0 la puissance active dans le cadre de la gestion de la demande avant d'allouer la marge r\u00e9siduelle de puissance apparente au soutien r\u00e9actif. Il s'agit d'un param\u00e9trage sp\u00e9cifique au projet, et non d'un param\u00e8tre par d\u00e9faut universel du produit.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-7468\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"9\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-7468\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Quels param\u00e8tres faut-il mesurer au PCC ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-7468\" class=\"elementor-element elementor-element-9491ef1b e-con-full e-flex e-con e-child\" data-id=\"9491ef1b\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-7468\" class=\"elementor-element elementor-element-b410ae5d e-con-full e-flex e-con e-child\" data-id=\"b410ae5d\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-048be408 elementor-widget elementor-widget-heading\" data-id=\"048be408\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Mesurer la tension synchronis\u00e9e, la puissance en kW, le courant r\u00e9actif en kVAr, la puissance active en kVA, le facteur de puissance, l'\u00e9nergie par intervalle, la puissance CA du syst\u00e8me de stockage d'\u00e9nergie par batterie (BESS), la r\u00e9ponse du syst\u00e8me de conversion de puissance (PCS), l'\u00e9tat de charge (SOC), la temp\u00e9rature, les alarmes et le mode de fonctionnement. Conserver les enregistrements relatifs aux alimentations s\u00e9par\u00e9ment des enregistrements du PCC pour l'ensemble du site.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-7469\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"10\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-7469\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Comment calcule-t-on le retour sur investissement (ROI) d'un syst\u00e8me BESS destin\u00e9 \u00e0 la r\u00e9duction de la demande ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-7469\" class=\"elementor-element elementor-element-417e8494 e-con-full e-flex e-con e-child\" data-id=\"417e8494\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-7469\" class=\"elementor-element elementor-element-3ea4c32d e-con-full e-flex e-con e-child\" data-id=\"3ea4c32d\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-17b0be95 elementor-widget elementor-widget-heading\" data-id=\"17b0be95\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Calculez chaque intervalle de facturation applicable \u00e0 partir des donn\u00e9es PCC mesur\u00e9es, puis appliquez le tarif. Tenez compte du co\u00fbt d'installation, du financement, de la maintenance, de la d\u00e9gradation, de l'\u00e9nergie auxiliaire, de l'\u00e9nergie de recharge, de la disponibilit\u00e9 et de la valeur pond\u00e9r\u00e9e en fonction de la probabilit\u00e9 de l'\u00e9vitement des perturbations.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-74610\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"11\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-74610\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Un test de 30 minutes peut-il permettre de d\u00e9montrer des \u00e9conomies annuelles ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-74610\" class=\"elementor-element elementor-element-219ca747 e-con-full e-flex e-con e-child\" data-id=\"219ca747\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-74610\" class=\"elementor-element elementor-element-05b88648 e-con-full e-flex e-con e-child\" data-id=\"05b88648\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-1ce660da elementor-widget elementor-widget-heading\" data-id=\"1ce660da\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Non. Il permet de valider un bilan \u00e9nerg\u00e9tique sur une p\u00e9riode donn\u00e9e dans des conditions bien d\u00e9finies. Pour calculer les \u00e9conomies annuelles, il faut se baser sur des hypoth\u00e8ses repr\u00e9sentatives concernant la charge saisonni\u00e8re, le tarif, la production, les interruptions de service et le temps de fonctionnement des batteries.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-74611\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"12\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-74611\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> La norme IP54 permet-elle de consid\u00e9rer qu'une armoire est adapt\u00e9e \u00e0 n'importe quel site ext\u00e9rieur ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-74611\" class=\"elementor-element elementor-element-3ba5da42 e-con-full e-flex e-con e-child\" data-id=\"3ba5da42\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-74611\" class=\"elementor-element elementor-element-f5e5428b e-con-full e-flex e-con e-child\" data-id=\"f5e5428b\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-5b44c1ed elementor-widget elementor-widget-heading\" data-id=\"5b44c1ed\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Non. La norme IP54 d\u00e9finit le degr\u00e9 de protection contre la p\u00e9n\u00e9tration d'eau et de poussi\u00e8re. Le projet n\u00e9cessite encore la mise en place d'une fondation, d'un syst\u00e8me de drainage, le respect des distances de s\u00e9curit\u00e9, une \u00e9tude de l'environnement, des acc\u00e8s pour la maintenance, une conception \u00e9lectrique et l'obtention d'un agr\u00e9ment local en mati\u00e8re de s\u00e9curit\u00e9 incendie.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-74612\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"13\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-74612\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> La composition chimique des batteries LFP ou les dispositifs de suppression \u00e9liminent-ils le risque d'emballement thermique ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-74612\" class=\"elementor-element elementor-element-61097e7b e-con-full e-flex e-con e-child\" data-id=\"61097e7b\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-74612\" class=\"elementor-element elementor-element-584abae0 e-con-full e-flex e-con e-child\" data-id=\"584abae0\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-e514f3d1 elementor-widget elementor-widget-heading\" data-id=\"e514f3d1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Non. Les risques thermiques doivent \u00eatre ma\u00eetris\u00e9s gr\u00e2ce \u00e0 une conception pr\u00e9cise des batteries et des syst\u00e8mes de contr\u00f4le, ainsi qu\u2019\u00e0 des dispositifs de d\u00e9tection, d\u2019extinction, de s\u00e9paration, d\u2019isolation d\u2019urgence, de limites d\u2019exploitation, de maintenance et \u00e0 un plan d\u2019urgence du site.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-74613\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"14\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-74613\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Quels documents relatifs \u00e0 la s\u00e9curit\u00e9 l'acheteur doit-il demander ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-74613\" class=\"elementor-element elementor-element-5057f2bc e-con-full e-flex e-con e-child\" data-id=\"5057f2bc\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-74613\" class=\"elementor-element elementor-element-f8c1ec66 e-con-full e-flex e-con e-child\" data-id=\"f8c1ec66\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-1900dc0c elementor-widget elementor-widget-heading\" data-id=\"1900dc0c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Demandez la nomenclature command\u00e9e, les limites du syst\u00e8me de gestion de l'incendie (BMS), les d\u00e9tails relatifs au refroidissement, la description des syst\u00e8mes de d\u00e9tection et d'extinction, la matrice de causes et d'effets, l'\u00e9tude des protections \u00e9lectriques, le sch\u00e9ma d'implantation, le plan d'urgence, les rapports d'essais pertinents et les limites de mise en service.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-74614\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"15\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-74614\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Le syst\u00e8me BESS peut-il fonctionner avec un groupe \u00e9lectrog\u00e8ne diesel ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-74614\" class=\"elementor-element elementor-element-ec36faff e-con-full e-flex e-con e-child\" data-id=\"ec36faff\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-74614\" class=\"elementor-element elementor-element-589ac86a e-con-full e-flex e-con e-child\" data-id=\"589ac86a\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c56bf6a2 elementor-widget elementor-widget-heading\" data-id=\"c56bf6a2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Oui, lors de la conception de l'architecture de contr\u00f4le. Il convient de d\u00e9finir la source de formation de r\u00e9seau, la plage de charge du g\u00e9n\u00e9rateur, les autorisations de charge, la protection contre la puissance inverse, la polarit\u00e9 des transformateurs de courant, la coordination des relais et l'\u00e9tat de secours avant le SAT.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-74615\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"16\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-74615\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Quels sont les crit\u00e8res \u00e0 respecter lors des essais de r\u00e9ception du site ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-74615\" class=\"elementor-element elementor-element-8c2d5841 e-con-full e-flex e-con e-child\" data-id=\"8c2d5841\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-74615\" class=\"elementor-element elementor-element-c8b9fc43 e-con-full e-flex e-con e-child\" data-id=\"c8b9fc43\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-6a51bdc0 elementor-widget elementor-widget-heading\" data-id=\"6a51bdc0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Le SAT doit v\u00e9rifier les limites de puissance et d'\u00e9nergie convenues pour le PCC, la r\u00e9ponse en tension, le comportement P-Q\/courant du PCS, la r\u00e9serve de SOC, la r\u00e9ponse des alarmes et des protections, les limites thermiques, les communications, la coh\u00e9rence des compteurs et la coordination des g\u00e9n\u00e9rateurs, le cas \u00e9ch\u00e9ant.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Guide pratique pour distinguer la prise en charge de la tension de d\u00e9marrage des moteurs de la r\u00e9duction de la demande sur 15 ou 30 minutes, pour dimensionner la puissance des syst\u00e8mes de compensation de puissance (PCS) en kVA et celle des syst\u00e8mes de stockage d'\u00e9nergie par batterie (BESS) en kWh, et pour valider le mod\u00e8le de retour sur investissement \u00e0 l'aide des donn\u00e9es du centre de contr\u00f4le de puissance (PCC).<\/p>","protected":false},"author":4,"featured_media":4821,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"_joinchat":[],"footnotes":""},"categories":[1,714],"tags":[342,184,364,362,363,365],"class_list":["post-4824","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-bess","category-ci-battery-storage-solutions","tag-demand-management","tag-essa0100b-0215","tag-industrial-bess","tag-motor-starting","tag-pcs-sizing","tag-site-acceptance-testing"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/posts\/4824","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/comments?post=4824"}],"version-history":[{"count":4,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/posts\/4824\/revisions"}],"predecessor-version":[{"id":6168,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/posts\/4824\/revisions\/6168"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/media\/4821"}],"wp:attachment":[{"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/media?parent=4824"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/categories?post=4824"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/tags?post=4824"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}