{"id":5150,"date":"2026-09-01T09:58:44","date_gmt":"2026-09-01T01:58:44","guid":{"rendered":"https:\/\/www.solidess.com\/?p=5150"},"modified":"2026-10-08T15:38:25","modified_gmt":"2026-10-08T07:38:25","slug":"conception-de-systemes-de-stockage-denergie-par-batterie-sites-ci","status":"publish","type":"post","link":"https:\/\/www.solidess.com\/fr\/battery-energy-storage-system-design-ci-sites\/","title":{"rendered":"Conception d'un syst\u00e8me de stockage pour sites C&amp;I"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"5150\" class=\"elementor elementor-5150\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-bf4793c e-con-full auto-article-root e-flex e-con e-parent\" data-id=\"bf4793c\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ac81e8d8 auto-p elementor-widget elementor-widget-heading\" data-id=\"ac81e8d8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Un projet de batterie \u00e0 usage commercial et industriel n'est pr\u00eat \u00e0 faire l'objet d'un appel d'offres que lorsque la conception pr\u00e9cise ce que le syst\u00e8me doit alimenter, pendant combien de temps, \u00e0 quelle tension et avec quel facteur de puissance, ainsi que son comportement au point de raccordement commun. MegSolid utilise ces donn\u00e9es pour s\u00e9lectionner la batterie, le syst\u00e8me de conversion de puissance (PCS) et les dispositifs de commande, tandis que l'EPC local se charge des aspects sp\u00e9cifiques au site. <strong><a href=\"https:\/\/www.solidess.com\/fr\/connexion-de-batterie-400-v-au-tableau-electrique-existant\/\" target=\"_blank\" style=\"color:#61ce70\">Raccordement au tableau \u00e9lectrique de 400 V<\/a><\/strong>, <strong><a href=\"https:\/\/www.solidess.com\/fr\/les-epc-doivent-demander-les-donnees-dentree-pour-la-conception-des-fondations-du-bess-exterieur\/\" target=\"_blank\" style=\"color:#61ce70\">Conception des fondations d'un syst\u00e8me BESS en ext\u00e9rieur<\/a><\/strong> et <strong><a href=\"https:\/\/www.solidess.com\/fr\/liste-des-points-scada-bess-ce-que-votre-ems-doit-envoyer\/\" target=\"_blank\" style=\"color:#61ce70\">Liste des points SCADA<\/a><\/strong>.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5cf57b40 auto-p elementor-widget elementor-widget-heading\" data-id=\"5cf57b40\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Une conception insuffisante se manifeste g\u00e9n\u00e9ralement lorsque l'une des six donn\u00e9es suivantes fait d\u00e9faut : la puissance continue requise en kW, la puissance r\u00e9active requise en kVA, l'\u00e9nergie requise en kWh CA, la limite de fonctionnement du PCC, les contraintes environnementales du site et les essais de r\u00e9ception. Si l\u2019un de ces \u00e9l\u00e9ments fait d\u00e9faut, un produit peut sembler conforme sur un devis et pourtant ne pas supporter la charge, d\u00e9clencher le tableau \u00e9lectrique, se recharger lors d\u2019un deuxi\u00e8me pic de demande ou \u00eatre livr\u00e9 sans les justificatifs n\u00e9cessaires \u00e0 la r\u00e9ception.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-221ef9b3 auto-image elementor-widget elementor-widget-image\" data-id=\"221ef9b3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"1254\" height=\"1254\" src=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Battery-Energy-Storage-System-Design-for-CI-Sites.png\" class=\"attachment-1536x1536 size-1536x1536 wp-image-5147\" alt=\"Processus de conception du syst\u00e8me de stockage d&#039;\u00e9nergie par batterie MegSolid C&amp;I avec des armoires r\u00e9elles, la puissance du PCS, l&#039;\u00e9nergie de la batterie, le PCC, l&#039;EMS et les tests FAT\/SAT\" srcset=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Battery-Energy-Storage-System-Design-for-CI-Sites.png 1254w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Battery-Energy-Storage-System-Design-for-CI-Sites-300x300.png 300w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Battery-Energy-Storage-System-Design-for-CI-Sites-1024x1024.png 1024w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Battery-Energy-Storage-System-Design-for-CI-Sites-150x150.png 150w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Battery-Energy-Storage-System-Design-for-CI-Sites-768x768.png 768w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Battery-Energy-Storage-System-Design-for-CI-Sites-12x12.png 12w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Battery-Energy-Storage-System-Design-for-CI-Sites-600x600.png 600w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Battery-Energy-Storage-System-Design-for-CI-Sites-100x100.png 100w\" sizes=\"(max-width: 1254px) 100vw, 1254px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b1e7201b auto-h2 elementor-widget elementor-widget-heading\" data-id=\"b1e7201b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">La conception doit aboutir \u00e0 six r\u00e9sultats v\u00e9rifiables<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1ea0733b auto-p elementor-widget elementor-widget-heading\" data-id=\"1ea0733b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">La conception d'un syst\u00e8me de stockage d'\u00e9nergie par batterie commence par la mesure des conditions sur site et aboutit \u00e0 des valeurs pouvant \u00eatre v\u00e9rifi\u00e9es lors des essais FAT et SAT. Une base de conception utile doit permettre d'identifier :<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a2e0523c elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"a2e0523c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">1. <strong>Alimentation en courant alternatif continu et transitoire :<\/strong> le d\u00e9ficit de puissance sur site prolong\u00e9, la charge de d\u00e9marrage des moteurs, la dur\u00e9e de la surcharge et les besoins en puissance r\u00e9active.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">2. <strong>\u00c9nergie CA requise :<\/strong> l'\u00e9nergie destin\u00e9e \u00e0 la charge prot\u00e9g\u00e9e ou \u00e0 l'\u00e9cr\u00eatement des pointes au point de livraison convenu, y compris la plage de SOC d'exploitation et les exigences relatives \u00e0 la fin de vie.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">3. <strong>Interface \u00e9lectrique :<\/strong> Emplacement du PCC, tension nominale, fr\u00e9quence, niveau de d\u00e9faut, disposition des disjoncteurs, trac\u00e9 des c\u00e2bles, m\u00e9thode de mise \u00e0 la terre et strat\u00e9gie de protection.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">4. <strong>Comportement de contr\u00f4le :<\/strong> modes de fonctionnement, priorit\u00e9s, emplacements des capteurs de courant et des compteurs, points de consigne, alarmes, communications et \u00e9tat de s\u00e9curit\u00e9 int\u00e9gr\u00e9e.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">5. <strong>Limite environnementale :<\/strong> temp\u00e9rature, altitude, humidit\u00e9, risque de condensation, poussi\u00e8re, eau, exposition au sel, rayonnement solaire, r\u00e9cepteur acoustique et acc\u00e8s pour la maintenance.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">6. <strong>Preuve d'acceptation :<\/strong> calculs, plans, fiches techniques, param\u00e8tres de protection, registres FAT, proc\u00e9dures SAT, limites des tests de capacit\u00e9 et documents de transfert.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1df6446b auto-p elementor-widget elementor-widget-heading\" data-id=\"1df6446b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Ces r\u00e9sultats permettent de distinguer un \u00e9cran de famille de produits d'un projet de construction finalis\u00e9. Un \u00e9cran permet de s\u00e9lectionner une famille. Les dimensions des c\u00e2bles, les param\u00e8tres de protection, les d\u00e9tails de g\u00e9nie civil et les permis n\u00e9cessitent toujours des donn\u00e9es relatives au chantier et l'intervention d'un ing\u00e9nieur local.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8fe3608e auto-h2 elementor-widget elementor-widget-heading\" data-id=\"8fe3608e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Commencez par examiner le profil de charge, puis v\u00e9rifiez les caract\u00e9ristiques nominales indiqu\u00e9es sur la plaque signal\u00e9tique de la batterie<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a1687990 auto-p elementor-widget elementor-widget-heading\" data-id=\"a1687990\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Ne commencez pas par consulter un catalogue de batteries. Commencez par les donn\u00e9es de comptage, les charges qui doivent rester aliment\u00e9es et la charge que le syst\u00e8me de stockage d'\u00e9nergie par batterie (BESS) doit prendre en charge.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-290f7907 auto-p elementor-widget elementor-widget-heading\" data-id=\"290f7907\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Pour l\u2019\u00e9cr\u00eatement des pics, utilisez les donn\u00e9es par intervalle provenant du m\u00eame compteur que celui qui d\u00e9finit la demande du r\u00e9seau. Un intervalle de facturation de 15 minutes peut masquer de brefs pics de production ; des donn\u00e9es plus fr\u00e9quentes sont donc utiles pour v\u00e9rifier la r\u00e9ponse du PCS et le fonctionnement en surcharge. Pour l\u2019alimentation de secours, r\u00e9pertoriez les charges par paliers plut\u00f4t que d\u2019indiquer une seule valeur totale en kW. D\u00e9terminez quels syst\u00e8mes de commande, \u00e9clairages de secours et syst\u00e8mes de communication n\u00e9cessitent une alimentation ininterrompue ; programmez les pompes, compresseurs ou \u00e9quipements de production pour les phases ult\u00e9rieures ; maintenez hors tension les charges diff\u00e9r\u00e9es approuv\u00e9es.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b9f14787 auto-p elementor-widget elementor-widget-heading\" data-id=\"b9f14787\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Un kit pratique comprend :<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-efd73b76 elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"efd73b76\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">au moins un mois repr\u00e9sentatif de donn\u00e9es sur la demande par intervalles, ainsi que les variations saisonni\u00e8res ou de production connues ;<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">un programme de charge prot\u00e9g\u00e9e indiquant la puissance en kW, en kVA ou le facteur de puissance, le mode de d\u00e9marrage et la dur\u00e9e requise ;<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">le sch\u00e9ma unifilaire et le PCC propos\u00e9 ;<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">les caract\u00e9ristiques nominales du transformateur, son imp\u00e9dance, sa tension et les informations disponibles concernant le courant de d\u00e9faut ;<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">puissance nominale du g\u00e9n\u00e9rateur, s\u00e9quence de l'ATS, charge minimale et restrictions relatives \u00e0 la puissance inverse ;<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Puissances nominales des onduleurs photovolta\u00efques, limites d'injection et production mesur\u00e9e ou mod\u00e9lis\u00e9e ;<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">la temp\u00e9rature ambiante, la temp\u00e9rature \u00e0 l'entr\u00e9e de l'\u00e9quipement, l'altitude, l'humidit\u00e9 et les conditions d'exposition ;<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">le d\u00e9lai de r\u00e9tablissement n\u00e9cessaire avant le prochain quart de travail ou la prochaine interruption pr\u00e9vue.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-675e5bdd auto-p elementor-widget elementor-widget-heading\" data-id=\"675e5bdd\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Si les donn\u00e9es mesur\u00e9es sont incompl\u00e8tes, pr\u00e9cisez l'hypoth\u00e8se et les \u00e9l\u00e9ments d'information encore n\u00e9cessaires. Une phrase telle que \u201c Charge prot\u00e9g\u00e9e de 80 kW pendant 60 minutes, sous r\u00e9serve d'un enregistrement d'une semaine et de la d\u00e9tection du d\u00e9marrage du compresseur \u201d peut servir d'introduction \u00e0 un \u00e9cran. En revanche, une phrase telle que \u201c Environ 100 kW d'alimentation de secours \u201d ne peut pas servir d'introduction.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-33d35bb5 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"33d35bb5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Puissance active, puissance apparente et \u00e9nergie<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-726f6467 auto-p elementor-widget elementor-widget-heading\" data-id=\"726f6467\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Les unit\u00e9s kW, kVA et kWh r\u00e9pondent \u00e0 diff\u00e9rentes questions de conception. Le kW d\u00e9crit la puissance active. Le kVA d\u00e9finit les exigences en mati\u00e8re de capacit\u00e9 de transport de courant du syst\u00e8me de conversion de puissance (PCS) et des \u00e9quipements \u00e0 courant alternatif. Le kWh indique pendant combien de temps la batterie peut alimenter une charge donn\u00e9e, une fois prises en compte les pertes et les limites de fonctionnement.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-03d39056 auto-p elementor-widget elementor-widget-heading\" data-id=\"03d39056\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">En cas de d\u00e9ficit prolong\u00e9 du site :<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c521bdaf auto-p elementor-widget elementor-widget-heading\" data-id=\"c521bdaf\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\"><strong>Alimentation en courant alternatif continu requise \u2265 d\u00e9ficit maximal soutenu du site apr\u00e8s un d\u00e9lestage approuv\u00e9<\/strong><\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ccc947c3 auto-p elementor-widget elementor-widget-heading\" data-id=\"ccc947c3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Lorsque le facteur de puissance de la charge est inf\u00e9rieur \u00e0 l'unit\u00e9 :<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6229c2e3 auto-p elementor-widget elementor-widget-heading\" data-id=\"6229c2e3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\"><strong>Puissance apparente requise (kVA) \u2265 puissance active requise (kW) \u00f7 facteur de puissance de conception<\/strong><\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f35cbfd8 auto-p elementor-widget elementor-widget-heading\" data-id=\"f35cbfd8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Pour les sauvegardes par \u00e9tapes :<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-cdbc03d9 auto-p elementor-widget elementor-widget-heading\" data-id=\"cdbc03d9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\"><strong>\u00c9nergie CA de la charge prot\u00e9g\u00e9e = \u03a3(charge en kW \u00d7 dur\u00e9e de l'\u00e9tape en h)<\/strong><\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-dee7a32a auto-p elementor-widget elementor-widget-heading\" data-id=\"dee7a32a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Lorsque le calcul part de l'\u00e9nergie nominale de la batterie :<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-563952bb auto-p elementor-widget elementor-widget-heading\" data-id=\"563952bb\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\"><strong>\u00c9nergie nominale requise de la batterie \u2265 \u00e9nergie CA de la charge prot\u00e9g\u00e9e \u00f7 (fraction de SOC utilisable \u00d7 rendement de distribution CA \u00d7 fraction de capacit\u00e9 en fin de vie)<\/strong><\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-64ced6dc auto-p elementor-widget elementor-widget-heading\" data-id=\"64ced6dc\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Chaque facteur doit \u00eatre d\u00e9limit\u00e9 de mani\u00e8re pr\u00e9cise. Le rendement de distribution en courant alternatif doit \u00eatre adapt\u00e9 \u00e0 la puissance de fonctionnement, \u00e0 la temp\u00e9rature et au parcours de conversion. La fraction de SOC utilisable doit correspondre \u00e0 la strat\u00e9gie d'exploitation, y compris toute r\u00e9serve conserv\u00e9e \u00e0 des fins de protection de la batterie. Le facteur de fin de vie doit correspondre \u00e0 la capacit\u00e9 exig\u00e9e par le contrat au point de service indiqu\u00e9.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-34d22b13 auto-p elementor-widget elementor-widget-heading\" data-id=\"34d22b13\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Si un fournisseur indique une puissance active garantie, comparez-la \u00e0 la charge requise au m\u00eame point de mesure de la puissance active. Ne divisez pas \u00e0 nouveau cette valeur de puissance active garantie par le rendement du PCS. N'utilisez le \u201c rendement maximal du syst\u00e8me \u201d comme rendement aller-retour que si la fiche technique et la m\u00e9thode d'essai le d\u00e9finissent explicitement de cette mani\u00e8re.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-46515464 auto-p elementor-widget elementor-widget-heading\" data-id=\"46515464\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Le fonctionnement transitoire fait l'objet d'une v\u00e9rification distincte. Un syst\u00e8me PCS fonctionnant en continu \u00e0 80 kW n\u00e9cessite tout de m\u00eame une v\u00e9rification distincte pour le d\u00e9marrage d'un compresseur de 80 kW. Le courant de d\u00e9marrage, la m\u00e9thode de d\u00e9marrage, la limite de chute de tension, la courbe de surcharge du PCS et la s\u00e9quence de charges simultan\u00e9es doivent \u00eatre valid\u00e9s avant que l'armoire puisse \u00eatre verrouill\u00e9e.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-53d31a09 auto-image elementor-widget elementor-widget-image\" data-id=\"53d31a09\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"1448\" height=\"1086\" src=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Size-Power-and-Energy-Separately.png\" class=\"attachment-1536x1536 size-1536x1536 wp-image-5148\" alt=\"Graphique de dimensionnement MegSolid C&amp;I BESS distinguant les valeurs en kW et kVA des PCS de celles en kWh des batteries, les d\u00e9marrages de moteurs, la plage de SOC et la plage de charge\" srcset=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Size-Power-and-Energy-Separately.png 1448w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Size-Power-and-Energy-Separately-300x225.png 300w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Size-Power-and-Energy-Separately-1024x768.png 1024w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Size-Power-and-Energy-Separately-768x576.png 768w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Size-Power-and-Energy-Separately-16x12.png 16w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Size-Power-and-Energy-Separately-600x450.png 600w\" sizes=\"(max-width: 1448px) 100vw, 1448px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e1aad7a6 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"e1aad7a6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">D\u00e9terminer ce que le BESS doit contr\u00f4ler<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d03ce245 auto-p elementor-widget elementor-widget-heading\" data-id=\"d03ce245\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Un syst\u00e8me de stockage d'\u00e9nergie par batterie (BESS) de type C&amp;I peut r\u00e9pondre \u00e0 plusieurs objectifs, mais ceux-ci doivent \u00eatre class\u00e9s selon un ordre de priorit\u00e9 explicite. Sinon, deux points de consigne, pourtant raisonnables pris isol\u00e9ment, risquent d'entrer en concurrence pour la m\u00eame capacit\u00e9 de batterie.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e6c4f27a auto-h3 elementor-widget elementor-widget-heading\" data-id=\"e6c4f27a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">\u00e9cr\u00eatage des pointes<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4c5f2d5b auto-p elementor-widget elementor-widget-heading\" data-id=\"4c5f2d5b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Le r\u00e9gulateur mesure la consommation d'\u00e9lectricit\u00e9 au point de raccordement (PCC) et proc\u00e8de \u00e0 la d\u00e9charge avant que la demande moyenne du r\u00e9seau ne d\u00e9passe la valeur cible. La conception n\u00e9cessite de prendre en compte l'intervalle de facturation, la latence du compteur, la r\u00e9ponse du PCS, le plafond de d\u00e9charge, le seuil minimal de SOC et une r\u00e8gle de r\u00e9tablissement qui ne g\u00e9n\u00e8re pas de nouveau pic. Le <strong><a href=\"https:\/\/www.solidess.com\/fr\/comment-specifier-un-controle-de-zero-injection-au-pcc-pour-un-systeme-de-stockage-denergie-par-batterie-bess\/\" target=\"_blank\" style=\"color:#61ce70\">Sp\u00e9cifications de contr\u00f4le du PCC<\/a><\/strong> devrait d\u00e9finir la polarit\u00e9 CT, la qualit\u00e9 des donn\u00e9es, les pertes de communication et la gestion des mesures obsol\u00e8tes.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3020ff92 auto-h3 elementor-widget elementor-widget-heading\" data-id=\"3020ff92\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Alimentation de secours<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ad37ca9b auto-p elementor-widget elementor-widget-heading\" data-id=\"ad37ca9b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">La conception pr\u00e9voit une puissance et une \u00e9nergie suffisantes pour le profil de charge critique par paliers. Elle d\u00e9finit \u00e9galement le comportement en cas de transfert, les responsabilit\u00e9s en mati\u00e8re de formation ou de suivi du r\u00e9seau, les conditions de red\u00e9marrage \u00e0 froid, les configurations du neutre et de la mise \u00e0 la terre, ainsi que l'ordre de r\u00e9activation des charges. Une page produit ne mentionnant pas de temps de transfert sp\u00e9cifique au mod\u00e8le ne garantit pas un transfert sans heurts.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-20b6578d auto-h3 elementor-widget elementor-widget-heading\" data-id=\"20b6578d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Recharge photovolta\u00efque et autoconsommation<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-98050a88 auto-p elementor-widget elementor-widget-heading\" data-id=\"98050a88\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Le syst\u00e8me de gestion de l'\u00e9nergie (EMS) recharge la batterie lorsque la production photovolta\u00efque d\u00e9passe le niveau d'utilisation sur site ou d'exportation autoris\u00e9, sous r\u00e9serve des limites relatives \u00e0 la tension de la batterie, \u00e0 l'\u00e9tat de charge (SOC), \u00e0 la temp\u00e9rature et au syst\u00e8me de conversion de puissance (PCS). Les modules photovolta\u00efques, la construction du champ photovolta\u00efque et l'installation solaire locale restent g\u00e9n\u00e9ralement dans le p\u00e9rim\u00e8tre du contrat EPC ou de l'appel d'offres local, sauf indication contraire dans le contrat. La conception du syst\u00e8me de stockage d'\u00e9nergie par batterie (BESS) n\u00e9cessite tout de m\u00eame des donn\u00e9es sur la puissance photovolta\u00efque, car la disponibilit\u00e9 de la recharge influe sur le plan de reprise.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d6e8b77d auto-h3 elementor-widget elementor-widget-heading\" data-id=\"d6e8b77d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Coordination des g\u00e9n\u00e9rateurs<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-277c5011 auto-p elementor-widget elementor-widget-heading\" data-id=\"277c5011\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">La s\u00e9quence de commande doit emp\u00eacher toute puissance inverse ind\u00e9sirable, toute charge faible instable et toute interf\u00e9rence entre les commandes de tension et de fr\u00e9quence. La charge minimale du g\u00e9n\u00e9rateur, sa capacit\u00e9 de rampe, le d\u00e9lai de d\u00e9marrage et l'\u00e9tat du disjoncteur doivent \u00eatre connus avant la validation d\u00e9finitive de la logique. La conception doit respecter une proc\u00e9dure d\u00e9finie <strong><a href=\"https:\/\/www.solidess.com\/fr\/controle-de-bess-et-de-groupe-electrogene-diesel-sans-declenchements-sur-puissance-inverse\/\" target=\"_blank\" style=\"color:#61ce70\">S\u00e9quence de commande du BESS et du groupe \u00e9lectrog\u00e8ne diesel<\/a><\/strong>, et non une simple mention g\u00e9n\u00e9rique du type \u201c compatible avec un g\u00e9n\u00e9rateur \u201d.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0d6bb94e auto-h3 elementor-widget elementor-widget-heading\" data-id=\"0d6bb94e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Exportations nulles<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e0c07b42 auto-p elementor-widget elementor-widget-heading\" data-id=\"e0c07b42\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">L'exportation nulle correspond \u00e0 une r\u00e9gulation en boucle ferm\u00e9e au niveau du PCC. Une case \u00e0 cocher dans la fiche technique ne suffit pas \u00e0 d\u00e9finir la boucle. Le sens de mesure, le biais d'importation de s\u00e9curit\u00e9, le seuil d'exportation, le d\u00e9lai, la bande morte de r\u00e9gulation et la r\u00e9ponse en cas de perte de communication font tous partie de la description fonctionnelle.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8e9629be auto-h2 elementor-widget elementor-widget-heading\" data-id=\"8e9629be\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">D\u00e9finir le PCC, le tableau de distribution et la limite de protection<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ffcd5ef9 auto-p elementor-widget elementor-widget-heading\" data-id=\"ffcd5ef9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Le point de couplage commun (PCC) sert de r\u00e9f\u00e9rence pour l'importation, l'exportation, la protection et le contr\u00f4le. Le fait de d\u00e9placer le transformateur de courant (TC) de l'entr\u00e9e du r\u00e9seau vers un tableau en aval modifie ce que per\u00e7oit le syst\u00e8me de gestion de l'\u00e9nergie (EMS). Un syst\u00e8me de stockage d'\u00e9nergie par batterie (BESS) peut r\u00e9guler parfaitement une limite erron\u00e9e si la conception n'identifie pas le PCC sur le sch\u00e9ma unifilaire.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-248503e5 auto-p elementor-widget elementor-widget-heading\" data-id=\"248503e5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Le dossier technique \u00e9lectrique doit comporter les \u00e9l\u00e9ments suivants :<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0d92748b elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"0d92748b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">puissance nominale du bus du tableau de distribution, r\u00e9sistance aux courts-circuits et disposition des voies de r\u00e9serve ;<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">puissance nominale, imp\u00e9dance, groupe vectoriel et type de neutre du transformateur ;<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Tension nominale du PCS et n\u00e9cessit\u00e9 d'un transformateur d'isolement ou d'un transformateur \u00e9l\u00e9vateur ;<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">conducteur du c\u00e2ble, isolation, m\u00e9thode d'installation, regroupement, longueur du trac\u00e9 et correction li\u00e9e \u00e0 la temp\u00e9rature ambiante ;<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">capacit\u00e9 de coupure et de fermeture des disjoncteurs, crit\u00e8res de discrimination et exigences en mati\u00e8re de d\u00e9clenchement \u00e0 distance ;<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">fonctions de protection contre les surintensit\u00e9s, les d\u00e9fauts \u00e0 la terre, la tension, la fr\u00e9quence, l'anti-\u00eelotage et d'interconnexion ;<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">rapport CT, classe, charge, polarit\u00e9, emplacement et voie de communication du compteur ;<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">l'arr\u00eat d'urgence, l'interface avec le syst\u00e8me d'extinction d'incendie et l'\u00e9tat de s\u00e9curit\u00e9 en cas de coupure de l'alimentation auxiliaire.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ea44c4c6 auto-p elementor-widget elementor-widget-heading\" data-id=\"ea44c4c6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">La classification PCS ne prouve pas que le tableau \u00e9lectrique existant soit en mesure de prendre en charge le raccordement. La contribution au courant de d\u00e9faut, la capacit\u00e9 thermique, la coordination des protections et les r\u00e8gles locales d'interconnexion n\u00e9cessitent des \u00e9tudes au niveau du projet. La norme IEEE 1547-2018 traite de l'interconnexion des ressources \u00e9nerg\u00e9tiques d\u00e9centralis\u00e9es (DER) et de leur interop\u00e9rabilit\u00e9 avec les r\u00e9seaux \u00e9lectriques, tandis que <a href=\"https:\/\/standards.ieee.org\/ieee\/1547.9\/10875\/\" target=\"_blank\" rel=\"noopener\">IEEE 1547.9-2022<\/a> fournit des orientations pour l'application de ces exigences au stockage d'\u00e9nergie. Les codes de r\u00e9seau locaux et l'autorit\u00e9 comp\u00e9tente restent pr\u00e9pond\u00e9rants.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f3158670 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"f3158670\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">V\u00e9rifier la compatibilit\u00e9 de l'architecture du produit avec le site<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d47671eb auto-p elementor-widget elementor-widget-heading\" data-id=\"d47671eb\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Le choix du produit doit respecter les valeurs limites requises, et non la valeur nominale en kWh la plus proche. Le tableau ci-dessous pr\u00e9sente une s\u00e9lection pr\u00e9liminaire de la gamme de produits MegSolid, bas\u00e9e sur les donn\u00e9es actuellement publi\u00e9es. La s\u00e9lection d\u00e9finitive n\u00e9cessite une fiche technique valid\u00e9e, ainsi que la prise en compte de la temp\u00e9rature et de l'altitude du site, du cycle de service, du facteur de puissance, d'une \u00e9tude de protection et d'une architecture \u00e9lectrique approuv\u00e9e.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3d4a774e auto-table elementor-widget elementor-widget-text-editor\" data-id=\"3d4a774e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"cea-table-wrap\"><table><thead><tr><th>Gamme de produits<\/th><th>Puissance et \u00e9nergie publi\u00e9es<\/th><th>Interface AC<\/th><th>Notes thermiques et notes relatives au site<\/th><th>Ajustement pr\u00e9liminaire<\/th><\/tr><\/thead><tbody><tr><td><strong><a href=\"https:\/\/www.solidess.com\/fr\/product\/systeme-de-stockage-denergie-en-armoire-exterieure\/\" target=\"_blank\" style=\"color:#61ce70\">ESSA0100B-0215<\/a><\/strong><\/td><td>100 kW \/ 215,04 kWh<\/td><td>400 V, 50\/60 Hz<\/td><td>Refroidissement par air intelligent ; indice de protection IP54 ; plage de fonctionnement d\u00e9clar\u00e9e : 0 \u00e0 45 \u00b0C<\/td><td>Armoire compacte C&amp;I dans laquelle la puissance, l'\u00e9nergie et les conditions environnementales restent dans les limites contr\u00f4l\u00e9es<\/td><\/tr><tr><td><strong><a href=\"https:\/\/www.solidess.com\/fr\/product\/stockage-denergie-solide-liquide-megasolide\/\" target=\"_blank\" style=\"color:#61ce70\">Energon 261.24<\/a><\/strong><\/td><td>125 kVA \/ 261,24 kWh<\/td><td>400 V ou 480 V, 50\/60 Hz<\/td><td>Refroidissement par liquide ; plage de fonctionnement indiqu\u00e9e : \u221220 \u00e0 55 \u00b0C ; d\u00e9classement au-del\u00e0 de 45 \u00b0C et au-del\u00e0 de 2 000 m<\/td><td>Sites n\u00e9cessitant une architecture \u00e0 refroidissement par liquide ou une plage de temp\u00e9rature ambiante plus large, en fonction de la puissance en kW au facteur de puissance du projet<\/td><\/tr><tr><td><strong><a href=\"https:\/\/www.solidess.com\/fr\/product\/systeme-de-stockage-denergie-conteneurise\/\" target=\"_blank\" style=\"color:#61ce70\">ESSC1000B-2150<\/a><\/strong><\/td><td>1 000 kW \/ 2,1504 MWh<\/td><td>400 V<\/td><td>Refroidissement par air \u00e0 r\u00e9gulation intelligente de la temp\u00e9rature<\/td><td>Installations C&amp;I de plus grande envergure ou applications industrielles o\u00f9 un syst\u00e8me int\u00e9gr\u00e9 de l'ordre du m\u00e9gawatt est adapt\u00e9 \u00e0 l'architecture du site<\/td><\/tr><tr><td><strong><a href=\"https:\/\/www.solidess.com\/fr\/product\/systeme-de-stockage-denergie-conteneurise-megasolid-5000intl\/\" target=\"_blank\" style=\"color:#61ce70\">5000INTL<\/a><\/strong><\/td><td>2,7 MW \/ 5,0159 MWh<\/td><td>690 V<\/td><td>Syst\u00e8me de refroidissement par liquide intelligent ; indice de protection IP55 ; plage de fonctionnement indiqu\u00e9e : \u221230 \u00e0 55 \u00b0C<\/td><td>Projets de plusieurs m\u00e9gawatts dot\u00e9s d'une architecture interne de 690 V et d'une conception de raccordement MT sp\u00e9cifique au projet<\/td><\/tr><\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-51359059 auto-p elementor-widget elementor-widget-heading\" data-id=\"51359059\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Ne remplacez pas la valeur de 125 kVA d'Energon par 125 kW tant que le facteur de puissance et la fiche technique correspondante n'ont pas \u00e9t\u00e9 v\u00e9rifi\u00e9s. Un conteneur de 5,0159 MWh laisse \u00e9galement un d\u00e9ficit de 3 MW non couvert si la puissance du PCS est de 2,7 MW. L'\u00e9nergie suppl\u00e9mentaire prolonge la dur\u00e9e de fonctionnement. Elle n'augmente pas la puissance du PCS.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4709d713 auto-p elementor-widget elementor-widget-heading\" data-id=\"4709d713\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Les mod\u00e8les ESSA mentionnent actuellement des cellules LFP. La plateforme ESSA peut prendre en charge des configurations de cellules sp\u00e9cifiques \u00e0 chaque projet, mais le nom de la gamme ne suffit pas \u00e0 lui seul \u00e0 prouver que chaque unit\u00e9 fournie utilise des cellules \u00e0 l'\u00e9tat solide. La composition chimique, le fournisseur des cellules et les justificatifs de conformit\u00e9 doivent correspondre au mod\u00e8le indiqu\u00e9 dans le devis et \u00e0 la documentation du projet.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2422c0c3 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"2422c0c3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Exemple concret : des donn\u00e9es de compteur \u00e0 une fourchette de conception<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-dd2d34a1 auto-p elementor-widget elementor-widget-heading\" data-id=\"dd2d34a1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Prenons l'exemple d'une usine dont la limite de soutirage autoris\u00e9e est de 500 kW. Les donn\u00e9es de comptage toutes les 15 minutes indiquent une demande normale de 420 kW et un pic de production r\u00e9current de 560 kW. Le d\u00e9ficit pr\u00e9liminaire li\u00e9 \u00e0 l'\u00e9cr\u00eatement des pics est le suivant :<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3c67986e auto-p elementor-widget elementor-widget-heading\" data-id=\"3c67986e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\"><strong>Puissance de r\u00e9gulation des pointes = 560 kW \u2212 500 kW = 60 kW<\/strong><\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-03ab70dd auto-p elementor-widget elementor-widget-heading\" data-id=\"03ab70dd\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Cela permet de d\u00e9terminer la contribution minimale en puissance active pendant le pic mesur\u00e9. Les exigences finales relatives au PCS incluent \u00e9galement la marge de contr\u00f4le, la charge en puissance r\u00e9active, la latence des donn\u00e9es et tout pic plus bref d\u00e9tect\u00e9 lors d'un enregistrement \u00e0 plus haute r\u00e9solution.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4a16d499 auto-p elementor-widget elementor-widget-heading\" data-id=\"4a16d499\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Cette m\u00eame centrale dispose d\u2019un programme de charge prot\u00e9g\u00e9e en deux phases :<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6758e250 auto-table elementor-widget elementor-widget-text-editor\" data-id=\"6758e250\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"cea-table-wrap\"><table><thead><tr><th>Sc\u00e8ne<\/th><th>Charger<\/th><th>Dur\u00e9e<\/th><th>\u00c9nergie CA<\/th><\/tr><\/thead><tbody><tr><td>Commandes, communications et entra\u00eenements essentiels<\/td><td>80 kW<\/td><td>15 min<\/td><td>20 kWh<\/td><\/tr><tr><td>R\u00e9duction de la charge des processus essentiels<\/td><td>45 kW<\/td><td>45 min<\/td><td>33,75 kWh<\/td><\/tr><tr><td><strong>Total<\/strong><\/td><td><\/td><td><strong>60 min<\/strong><\/td><td><strong>53,75 kWh<\/strong><\/td><\/tr><\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-943bfd35 auto-p elementor-widget elementor-widget-heading\" data-id=\"943bfd35\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Avec un facteur de puissance nominal de 0,86, la puissance apparente requise pour le premier \u00e9tage est de :<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c18d20c6 auto-p elementor-widget elementor-widget-heading\" data-id=\"c18d20c6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\"><strong>Puissance apparente requise = 80 kW \u00f7 0,86 = 93,0 kVA<\/strong><\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b4b8b3a7 auto-p elementor-widget elementor-widget-heading\" data-id=\"b4b8b3a7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Cette valeur ne permet de vider l'\u00e9cran continu de la plaque signal\u00e9tique que pour les \u00e9quipements d'une puissance sup\u00e9rieure \u00e0 93 kVA dans les conditions du projet. Le d\u00e9marrage des moteurs doit encore faire l'objet d'une v\u00e9rification distincte. Tant que les donn\u00e9es relatives au plus grand nombre de d\u00e9marrages simultan\u00e9s, \u00e0 la m\u00e9thode de d\u00e9marrage, \u00e0 la limite de chute de tension et \u00e0 la courbe de surcharge du PCS ne sont pas disponibles, le mod\u00e8le reste une orientation pr\u00e9liminaire.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-39d66742 auto-p elementor-widget elementor-widget-heading\" data-id=\"39d66742\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Si la fraction SOC utilisable convenue est de 80%, que le rendement de livraison AC utilis\u00e9 pour le point de fonctionnement est de 92% et que le contrat exige une capacit\u00e9 en fin de vie de 80%, le crit\u00e8re d'\u00e9nergie nominale est le suivant :<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4756dbf4 auto-p elementor-widget elementor-widget-heading\" data-id=\"4756dbf4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\"><strong>\u00c9nergie nominale requise \u2265 53,75 kWh \u00f7 (0,80 \u00d7 0,92 \u00d7 0,80) = 91,3 kWh<\/strong><\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2e02f519 auto-p elementor-widget elementor-widget-heading\" data-id=\"2e02f519\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Ces pourcentages constituent des hypoth\u00e8ses techniques pour cet exemple et ne constituent en aucun cas des garanties universelles de MegSolid. Remplacez-les par les donn\u00e9es r\u00e9elles du projet. Le calcul de la r\u00e9cup\u00e9ration pour la prochaine \u00e9quipe est \u00e9galement important. Lorsque l'usine se maintient pr\u00e8s de son plafond d'importation, la puissance de recharge disponible d\u00e9termine le temps n\u00e9cessaire pour r\u00e9cup\u00e9rer les 53,75 kWh consomm\u00e9s.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f117b193 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"f117b193\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">V\u00e9rifiez la plage de charge avant de r\u00e9gler la capacit\u00e9 de la batterie<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-49b4fc97 auto-p elementor-widget elementor-widget-heading\" data-id=\"49b4fc97\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Une batterie dont la capacit\u00e9 a \u00e9t\u00e9 adapt\u00e9e en fonction de la d\u00e9charge peut tout de m\u00eame s'av\u00e9rer inutilisable si le site ne peut pas la recharger avant la prochaine intervention. La limite de charge doit \u00eatre calcul\u00e9e au PCC :<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4dba6d9e auto-p elementor-widget elementor-widget-heading\" data-id=\"4dba6d9e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\"><strong>Puissance de charge autoris\u00e9e du syst\u00e8me de stockage d'\u00e9nergie par batterie (BESS) = limite de soutirage \u2212 demande simultan\u00e9e de l'installation \u2212 marge technique<\/strong><\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f0a12804 auto-p elementor-widget elementor-widget-heading\" data-id=\"f0a12804\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Si la limite de soutirage de la centrale est de 500 kW, que la demande simultan\u00e9e est de 430 kW et que la marge convenue est de 20 kW, il ne reste que 50 kW pour la recharge. Une recharge \u00e0 un point de consigne plus \u00e9lev\u00e9 reproduirait pr\u00e9cis\u00e9ment le pic de demande que le syst\u00e8me est cens\u00e9 \u00e9liminer.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c2d0bd6b auto-p elementor-widget elementor-widget-heading\" data-id=\"c2d0bd6b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Le projet doit pr\u00e9ciser :<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b9879828 elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"b9879828\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">l'\u00e9nergie n\u00e9cessaire \u00e0 la remise en \u00e9tat apr\u00e8s chaque mode de fonctionnement ;<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">la date de reprise la plus pr\u00e9coce et la plus tardive acceptables ;<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Disponibilit\u00e9 de la recharge photovolta\u00efque et incertitude des pr\u00e9visions ;<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">limites de recharge sur le r\u00e9seau en fonction de l'heure d'utilisation ou des instructions du fournisseur d'\u00e9lectricit\u00e9 ;<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">limites de puissance de charge de la batterie et du PCS en fonction du SOC et de la temp\u00e9rature ;<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Que se passe-t-il lorsque la r\u00e9serve de secours entre en conflit avec la restauration visant \u00e0 r\u00e9duire les pics de consommation ?.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c414f8d7 auto-p elementor-widget elementor-widget-heading\" data-id=\"c414f8d7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Le syst\u00e8me EMS doit d\u00e9clencher une alerte claire indiquant \u201c r\u00e9serve non r\u00e9cup\u00e9rable avant la date limite \u201d lorsque la puissance de charge disponible est insuffisante. Si l\u2019objectif de r\u00e9serve n\u2019est pas atteint sans qu\u2019une alerte ne soit d\u00e9clench\u00e9e, l\u2019\u00e9quipe suivante pourrait consid\u00e9rer que la r\u00e9serve est pr\u00eate alors qu\u2019elle ne l\u2019est pas.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6be68b71 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"6be68b71\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Conception adapt\u00e9e \u00e0 la temp\u00e9rature, \u00e0 l'altitude, \u00e0 la poussi\u00e8re, \u00e0 l'eau et au bruit<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f82d5dea auto-p elementor-widget elementor-widget-heading\" data-id=\"f82d5dea\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Le programme environnemental doit tenir compte des conditions d'admission de l'\u00e9quipement, et pas seulement des moyennes m\u00e9t\u00e9orologiques r\u00e9gionales. Une armoire situ\u00e9e \u00e0 proximit\u00e9 d\u2019un mur chauff\u00e9 par le soleil ou d\u2019un conduit d\u2019\u00e9vacuation de processus peut pr\u00e9senter une temp\u00e9rature d\u2019admission plus \u00e9lev\u00e9e que celle relev\u00e9e par la station m\u00e9t\u00e9orologique. La densit\u00e9 r\u00e9duite de l\u2019air en altitude affecte le refroidissement et n\u00e9cessite de v\u00e9rifier la puissance disponible du syst\u00e8me de refroidissement (PCS). L\u2019accumulation de poussi\u00e8re modifie la perte de charge des filtres et la fr\u00e9quence d\u2019entretien. L\u2019air humide peut se condenser sur les surfaces internes m\u00eame si la pluie ne p\u00e9n\u00e8tre jamais dans l\u2019enceinte.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-307e8786 auto-p elementor-widget elementor-widget-heading\" data-id=\"307e8786\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Pour chaque site, notez :<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e58b00d8 elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"e58b00d8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">temp\u00e9rature ambiante maximale et minimale ;<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">temp\u00e9rature maximale pr\u00e9vue \u00e0 l'entr\u00e9e de l'\u00e9quipement sous l'effet de la chaleur solaire et de celle provenant de l'installation voisine ;<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">l'altitude d'installation et la limite de d\u00e9classement indiqu\u00e9e par le fabricant ;<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">humidit\u00e9 relative, plage de points de ros\u00e9e et historique de condensation ;<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">type de poussi\u00e8re, sch\u00e9ma de chargement, acc\u00e8s au filtre et fr\u00e9quence de remplacement ;<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">exposition \u00e0 la pluie, aux jets d\u2019eau, aux inondations et aux probl\u00e8mes de drainage ;<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">distance par rapport au littoral, d\u00e9p\u00f4t de sel et cat\u00e9gorie de corrosion ;<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">r\u00e9cepteur acoustique le plus proche et crit\u00e8re de bruit diurne\/nocturne applicable.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f3c08589 auto-p elementor-widget elementor-widget-heading\" data-id=\"f3c08589\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">L'indice de protection IP ne prend pas en compte le refroidissement, le sel, la condensation ni le bruit. Ces \u00e9l\u00e9ments doivent faire l'objet de justifications distinctes. La r\u00e8gle de conception est la suivante :<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-348e987c auto-p elementor-widget elementor-widget-heading\" data-id=\"348e987c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\"><strong>Puissance CA continue requise \u2264 puissance CA disponible garantie aux conditions de temp\u00e9rature, d'altitude et de facteur de puissance du projet<\/strong><\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6eecdda1 auto-p elementor-widget elementor-widget-heading\" data-id=\"6eecdda1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Si le site se situe en dehors d'une plage publi\u00e9e, n'inventez pas de courbe de d\u00e9classement proportionnelle. Renseignez-vous aupr\u00e8s du fabricant pour conna\u00eetre la limite autoris\u00e9e ou modifiez l'architecture.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-08f1548d elementor-tablet-align-center elementor-align-center auto-cta elementor-widget elementor-widget-button\" data-id=\"08f1548d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"#elementor-action%3Aaction%3Dpopup%3Aopen%26settings%3DeyJpZCI6Ijk0OCIsInRvZ2dsZSI6ZmFsc2V9\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Analyse des donn\u00e9es de conception du syst\u00e8me BESS C&amp;I<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-23f10b92 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"23f10b92\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">D\u00e9finir l'architecture EMS, SCADA et des compteurs<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e414cd66 auto-p elementor-widget elementor-widget-heading\" data-id=\"e414cd66\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">La conception d'un syst\u00e8me de r\u00e9gulation n\u00e9cessite une liste des points de consigne et une s\u00e9quence de fonctionnement. Un sch\u00e9ma repr\u00e9sentant \u201c EMS \u201d sous la forme d'une simple case ne pr\u00e9cise ni le responsable du point de consigne, ni le compteur qui ferme la boucle, ni la mesure \u00e0 prendre en cas de perte de communication.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-90e39027 auto-p elementor-widget elementor-widget-heading\" data-id=\"90e39027\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Indiquez au minimum :<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6c940ea5 elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"6c940ea5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Puissance active, puissance r\u00e9active, tension, courant, fr\u00e9quence et \u00e9tat du disjoncteur du PCC ;<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">niveau de charge de la batterie (SOC), \u00e9tat de sant\u00e9, puissance de charge\/d\u00e9charge disponible et limites de temp\u00e9rature ;<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">\u00c9tat de fonctionnement du PCS, kW, kVA, facteur de puissance, alarmes et \u00e9tat local\/\u00e0 distance ;<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">La disponibilit\u00e9 des panneaux photovolta\u00efques et du g\u00e9n\u00e9rateur, leur production et l'\u00e9tat des disjoncteurs y ont \u00e9t\u00e9 int\u00e9gr\u00e9s ;<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">limite d'importation\/exportation des services publics et mode de fonctionnement actif ;<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">source de la commande, priorit\u00e9, droits d'\u00e9criture et d\u00e9lai d'expiration de la commande ;<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">synchronisation horaire, intervalle d'archivage et dur\u00e9e de conservation des enregistrements d'\u00e9v\u00e9nements ;<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">mesures de s\u00e9curit\u00e9 en cas de donn\u00e9es erron\u00e9es, de CT invers\u00e9s, de valeurs fig\u00e9es et de perte de communication.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ab6f4b7c auto-p elementor-widget elementor-widget-heading\" data-id=\"ab6f4b7c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Les essais de r\u00e9ception des commandes doivent v\u00e9rifier le signe et le sens. Un transformateur de courant PCC invers\u00e9 peut faire passer une commande de d\u00e9charge pour une augmentation des importations, ce qui peut amener le r\u00e9gulateur \u00e0 intensifier ses efforts dans la mauvaise direction. Le SAT doit simuler ou cr\u00e9er en toute s\u00e9curit\u00e9 des conditions d\u2019importation et d\u2019exportation, confirmer le signe mesur\u00e9 et v\u00e9rifier que la perte du compteur principal entra\u00eene l\u2019\u00e9tat de s\u00e9curit\u00e9 sp\u00e9cifi\u00e9.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f8d383b3 auto-p elementor-widget elementor-widget-heading\" data-id=\"f8d383b3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">La protection anti-surcompensation doit \u00e9galement figurer dans le cahier des charges. Lorsque la batterie atteint son \u00e9tat de charge (SOC) ou sa limite de puissance, le r\u00e9gulateur doit cesser d'accumuler une correction impossible. Sans ce comportement, le syst\u00e8me risque de d\u00e9passer la valeur cible lorsque la contrainte dispara\u00eet.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1f25031b auto-h2 elementor-widget elementor-widget-heading\" data-id=\"1f25031b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Adapter les donn\u00e9es relatives \u00e0 la s\u00e9curit\u00e9 au syst\u00e8me concern\u00e9<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0a970794 auto-p elementor-widget elementor-widget-heading\" data-id=\"0a970794\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Les preuves de s\u00e9curit\u00e9 doivent \u00eatre sp\u00e9cifiques au mod\u00e8le et \u00e0 la configuration, et doivent pouvoir \u00eatre rattach\u00e9es au syst\u00e8me fourni. Un certificat de cellule ne certifie pas l\u2019armoire dans son ensemble. Un essai r\u00e9alis\u00e9 sur une armoire ne couvre pas automatiquement un conteneur plus grand, une cellule diff\u00e9rente, un espacement diff\u00e9rent entre les modules, un syst\u00e8me de refroidissement diff\u00e9rent ou une configuration anti-incendie diff\u00e9rente.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-79f1fcaa auto-p elementor-widget elementor-widget-heading\" data-id=\"79f1fcaa\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Voici quelques r\u00e9f\u00e9rences utiles :<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a870377d elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"a870377d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><a href=\"https:\/\/www.ul.com\/services\/energy-storage-system-testing-and-certification\" target=\"_blank\" style=\"color:#61CE70\" rel=\"noopener\">UL 9540<\/a> pour les syst\u00e8mes complets de stockage d\u2019\u00e9nergie et leurs \u00e9quipements de charge, de d\u00e9charge, de protection, de contr\u00f4le et de communication ;<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><a href=\"https:\/\/www.ul.com\/services\/ul-9540a-test-method\" target=\"_blank\" style=\"color:#61CE70\" rel=\"noopener\">UL 9540A<\/a> pour \u00e9valuer les caract\u00e9ristiques de propagation d'un incendie d\u00fb \u00e0 un emballement thermique ;<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><a href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-855-standard-development\/855\" target=\"_blank\" style=\"color:#61CE70\" rel=\"noopener\">NFPA 855<\/a> concernant les exigences minimales visant \u00e0 att\u00e9nuer les risques li\u00e9s aux syst\u00e8mes de stockage d'\u00e9nergie (ESS) ;<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><a href=\"https:\/\/webstore.iec.ch\/en\/publication\/68297\" target=\"_blank\" style=\"color:#61CE70\" rel=\"noopener\">IEC 62933-5-2:2025<\/a> concernant les exigences de s\u00e9curit\u00e9 relatives aux risques li\u00e9s aux interactions entre sous-syst\u00e8mes dans les syst\u00e8mes de stockage d'\u00e9nergie \u00e9lectrochimiques ;<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><a href=\"https:\/\/webstore.iec.ch\/en\/publication\/85023\" target=\"_blank\" style=\"color:#61CE70\" rel=\"noopener\">IEC TR 62933-3-200:2025<\/a> pour les principes de conception, notamment le dimensionnement, le choix des sous-syst\u00e8mes, l'int\u00e9gration, l'am\u00e9nagement du site et les mesures de s\u00e9curit\u00e9.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a56cce03 auto-p elementor-widget elementor-widget-heading\" data-id=\"a56cce03\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Le r\u00e9f\u00e9rentiel applicable d\u00e9pend du pays, de l'autorit\u00e9 comp\u00e9tente, de l'assureur, du type d'installation et du contrat. Le tableau de conformit\u00e9 doit pr\u00e9ciser le mod\u00e8le exact, la r\u00e9vision, la norme d'essai, le num\u00e9ro de rapport, le laboratoire, la configuration et les \u00e9ventuelles restrictions. Une mention \u201c conforme aux normes UL \u201d ou \u201c certifi\u00e9 IEC \u201d sans cette tra\u00e7abilit\u00e9 ne constitue pas un document de validation.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-db9ea902 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"db9ea902\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">D\u00e9limiter clairement les responsabilit\u00e9s du fabricant et celles de l'EPC<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-263f4b0a auto-p elementor-widget elementor-widget-heading\" data-id=\"263f4b0a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Des lacunes en mati\u00e8re de responsabilit\u00e9 apparaissent souvent au niveau des bornes de c\u00e2bles, de la limite du compteur, de l'alimentation auxiliaire et de l'interface de mise en service. Une matrice des responsabilit\u00e9s doit \u00eatre convenue avant la passation de la commande.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-112786ec auto-table elementor-widget elementor-widget-text-editor\" data-id=\"112786ec\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"cea-table-wrap\"><table><thead><tr><th>T\u00e2che<\/th><th>MegSolid \/ fournisseur d'\u00e9quipements<\/th><th>Ing\u00e9nieur EPC \/ ing\u00e9nieur de projet local<\/th><th>V\u00e9rification conjointe<\/th><\/tr><\/thead><tbody><tr><td>Configuration du BESS et du PCS<\/td><td>Donn\u00e9es relatives au mod\u00e8le contr\u00f4l\u00e9, limites d'exploitation et exigences en mati\u00e8re d'interface<\/td><td>V\u00e9rifier la compatibilit\u00e9 entre les fonctions et le site<\/td><td>Liste des \u00e9quipements approuv\u00e9s<\/td><\/tr><tr><td>Travaux de g\u00e9nie civil et fondations<\/td><td>Dimensions de l'\u00e9quipement, masse, donn\u00e9es relatives au levage et \u00e0 l'ancrage<\/td><td>\u00c9tude g\u00e9otechnique, fondations, drainage, voies d'acc\u00e8s et validation locale des plans<\/td><td>Analyse de l'interface de dessin<\/td><\/tr><tr><td>Travaux d'\u00e9lectricit\u00e9 li\u00e9s \u00e0 la AC et aux \u00e9quipements auxiliaires<\/td><td>Donn\u00e9es des bornes, exigences relatives aux charges auxiliaires et interface de protection<\/td><td>\u00c9tudes relatives aux appareillages de commutation, aux c\u00e2bles, \u00e0 la mise \u00e0 la terre, aux transformateurs et \u00e0 la protection des sites<\/td><td>SLD et examen des r\u00e9siliations<\/td><\/tr><tr><td>EMS et SCADA<\/td><td>Signaux, protocoles, limites et logique c\u00f4t\u00e9 \u00e9quipement pris en charge<\/td><td>Compteur de site, r\u00e9seau, int\u00e9gration SCADA et interface avec les services publics<\/td><td>Tests point \u00e0 point et tests fonctionnels<\/td><\/tr><tr><td>Interface incendie et urgences<\/td><td>Informations relatives \u00e0 la d\u00e9tection et \u00e0 la suppression des syst\u00e8mes fournis<\/td><td>Plan de s\u00e9curit\u00e9 incendie du site, acc\u00e8s, interfaces externes et autorisation des autorit\u00e9s<\/td><td>Test de causalit\u00e9<\/td><\/tr><tr><td>FAT<\/td><td>Proc\u00e9dures d'usine, \u00e9quipements d'essai et registres contr\u00f4l\u00e9s<\/td><td>Exigences relatives aux t\u00e9moins et plan d'essai approuv\u00e9<\/td><td>Cl\u00f4ture de la liste des travaux \u00e0 r\u00e9aliser<\/td><\/tr><tr><td>Installation et SAT<\/td><td>Manuels d'installation et assistance technique inclus dans le contrat<\/td><td>Installation, autorisations locales, mise sous tension et s\u00e9curit\u00e9 sur le chantier<\/td><td>SAT, test de performance et transfert<\/td><\/tr><\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-55ad5ad3 auto-p elementor-widget elementor-widget-heading\" data-id=\"55ad5ad3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Le contrat commercial peut modifier ces limites, mais il doit le faire de mani\u00e8re explicite. MegSolid fournit le BESS, le PCS ou le syst\u00e8me int\u00e9gr\u00e9, ainsi que la documentation technique associ\u00e9e et l'assistance pour les essais d'acceptation sur site (FAT), dans le cadre du p\u00e9rim\u00e8tre convenu. Les travaux de g\u00e9nie civil locaux, les appareillages de commutation, le c\u00e2blage, les autorisations et l'installation restent \u00e0 la charge de l'EPC local, sauf si le contrat sign\u00e9 en attribue la responsabilit\u00e9 \u00e0 une autre partie.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e8dc8b34 auto-h3 elementor-widget elementor-widget-heading\" data-id=\"e8dc8b34\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Transformer les donn\u00e9es du site en base de conception<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2920cd5b auto-p elementor-widget elementor-widget-heading\" data-id=\"2920cd5b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Veuillez nous transmettre le fichier de charge par intervalle, le programme de charge prot\u00e9g\u00e9, le sch\u00e9ma unifilaire, la tension sur site, le facteur de puissance, la temp\u00e9rature, l'altitude et les objectifs d'exploitation. La premi\u00e8re analyse permettra d'identifier la plage de puissance et d'\u00e9nergie, les points techniques en suspens et la gamme de produits MegSolid adapt\u00e9e, sans consid\u00e9rer les hypoth\u00e8ses comme des param\u00e8tres d\u00e9finitifs.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a46b07e8 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"a46b07e8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Pr\u00e9voir des marges FAT et SAT pour pallier les risques li\u00e9s \u00e0 la conception<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3c6450a9 auto-p elementor-widget elementor-widget-heading\" data-id=\"3c6450a9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Le FAT permet de v\u00e9rifier le mat\u00e9riel fourni et la logique avant l'exp\u00e9dition. Le SAT permet de v\u00e9rifier le syst\u00e8me install\u00e9, le c\u00e2blage sur site, les compteurs, les interfaces de protection et le comportement r\u00e9el en fonctionnement. Le FAT et le SAT ne sont pas interchangeables.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a6f29277 auto-image elementor-widget elementor-widget-image\" data-id=\"a6f29277\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"1448\" height=\"1086\" src=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/BESS-Design-Release-Path.png\" class=\"attachment-1536x1536 size-1536x1536 wp-image-5149\" alt=\"Parcours de mise en service de la conception du syst\u00e8me de stockage d&#039;\u00e9nergie MegSolid BESS, depuis le profil de charge jusqu&#039;aux valeurs en kW, kVA et kWh, en passant par la protection PCC, l&#039;EMS, les tests FAT et SAT et la remise au client\" srcset=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/BESS-Design-Release-Path.png 1448w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/BESS-Design-Release-Path-300x225.png 300w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/BESS-Design-Release-Path-1024x768.png 1024w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/BESS-Design-Release-Path-768x576.png 768w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/BESS-Design-Release-Path-16x12.png 16w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/BESS-Design-Release-Path-600x450.png 600w\" sizes=\"(max-width: 1448px) 100vw, 1448px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b4dcf9a9 auto-p elementor-widget elementor-widget-heading\" data-id=\"b4dcf9a9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Sp\u00e9cifique \u00e0 un projet <strong><a href=\"https:\/\/www.solidess.com\/fr\/guide-dessai-de-reception-en-usine-de-bess\/\" target=\"_blank\" style=\"color:#61ce70\">Essai de r\u00e9ception en usine du syst\u00e8me BESS<\/a><\/strong> doit inclure, le cas \u00e9ch\u00e9ant :<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-41e2a82d elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"41e2a82d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">v\u00e9rification du mod\u00e8le, du num\u00e9ro de s\u00e9rie, du micrologiciel et de la version du plan ;<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">contr\u00f4les visuels, m\u00e9caniques, de c\u00e2blage et de respect des couples de serrage ;<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">v\u00e9rification de l'isolation, de la mise \u00e0 la terre de protection et de l'alimentation auxiliaire ;<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">batterie, PCS, CVC ou refroidissement par liquide, alarmes incendie et d'arr\u00eat d'urgence ;<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">op\u00e9ration de charge et de d\u00e9charge aux points d'essai convenus ;<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Tests du mode EMS, de la consigne, des limites, des alarmes et de la perte de communication ;<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">V\u00e9rification des registres SCADA et des horodatages ;<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">liste des travaux \u00e0 r\u00e9aliser et dossier de pi\u00e8ces justificatives, le tout faisant l'objet d'un suivi rigoureux.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-70d38358 auto-p elementor-widget elementor-widget-heading\" data-id=\"70d38358\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">SAT devrait ajouter les \u00e9l\u00e9ments qui ne sont pas fournis d'origine :<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-05f27762 elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"05f27762\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">rapport CT, polarit\u00e9 et sens de la puissance PCC ;<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">disjoncteurs, dispositifs de verrouillage, arr\u00eats d'urgence et d\u00e9clenchements de protection ;<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">les voies de communication du site et le comportement en cas de perte de signal ;<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">r\u00e9duction des pics de consommation ou r\u00e9ponse \u00ab z\u00e9ro exportation \u00bb au niveau du compteur lui-m\u00eame ;<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">le g\u00e9n\u00e9rateur et la s\u00e9quence ATS, lorsqu'ils \u00e9taient inclus ;<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">transfert et r\u00e9tablissement progressifs de la charge prot\u00e9g\u00e9e ;<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">limite de r\u00e9cup\u00e9ration de charge \u00e0 la fronti\u00e8re d'importation op\u00e9rationnelle ;<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">essai de capacit\u00e9 ou de performance au point AC d\u00e9fini dans le contrat.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-148f4521 auto-p elementor-widget elementor-widget-heading\" data-id=\"148f4521\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Si un test de capacit\u00e9 n'atteint pas la valeur cible sans d\u00e9clencher d'alarme, v\u00e9rifiez tout d'abord les limites du test, le SOC initial, les charges auxiliaires, la temp\u00e9rature, le niveau de puissance, les limites de tension et les conditions d'arr\u00eat anticip\u00e9. La m\u00e9thode de d\u00e9pannage d\u00e9crite dans <strong><a href=\"https:\/\/www.solidess.com\/fr\/pourquoi-un-bess-echoue-a-son-test-de-capacite-sans-declencher-dalarme\/\" target=\"_blank\" style=\"color:#61ce70\">Analyse des tests de capacit\u00e9 du syst\u00e8me BESS<\/a><\/strong> emp\u00eache de comparer la valeur nominale en courant continu avec un r\u00e9sultat en courant alternatif non corrig\u00e9.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-00a64eb8 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"00a64eb8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Liste de contr\u00f4le pour la r\u00e9vision de conception avant la mise en service de l'\u00e9quipement<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1a55e1cc auto-p elementor-widget elementor-widget-heading\" data-id=\"1a55e1cc\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">La liste de contr\u00f4le suivante est suffisamment concise pour \u00eatre utilis\u00e9e lors d'une r\u00e9union de conception et suffisamment stricte pour \u00e9viter tout achat pr\u00e9matur\u00e9 :<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f1d933d6 elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"f1d933d6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>Fonction :<\/strong> Les priorit\u00e9s en mati\u00e8re de r\u00e9duction des pics de consommation, d'alimentation de secours, de recharge photovolta\u00efque, d'appoint par g\u00e9n\u00e9rateur et de gestion des exportations sont class\u00e9es par ordre d'importance.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>Donn\u00e9es :<\/strong> L'intervalle de mesure, la qualit\u00e9 de l'horodatage, les donn\u00e9es manquantes et la base saisonni\u00e8re sont enregistr\u00e9s.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>Puissance :<\/strong> La puissance continue en kW et en kVA, le facteur de puissance, les d\u00e9marrages du moteur et la dur\u00e9e des surcharges sont v\u00e9rifi\u00e9s.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>\u00c9nergie :<\/strong> La limite de fourniture en courant alternatif, la fen\u00eatre SOC, les pertes, la d\u00e9gradation et la capacit\u00e9 requise en fin de vie sont d\u00e9finies.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>R\u00e9tablissement :<\/strong> La puissance de recharge disponible et le d\u00e9lai de reconstitution de la r\u00e9serve sont calcul\u00e9s.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>Connexion :<\/strong> Les donn\u00e9es relatives au courant de courant continu (PCC), \u00e0 la tension, au niveau de d\u00e9faut, au transformateur, au tableau de distribution, au c\u00e2ble et \u00e0 la mise \u00e0 la terre ont \u00e9t\u00e9 valid\u00e9es.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>Commandes :<\/strong> Les informations relatives \u00e0 la propri\u00e9t\u00e9 du compteur, \u00e0 la priorit\u00e9 de commande, \u00e0 l'\u00e9tat de s\u00e9curit\u00e9 int\u00e9gr\u00e9e, aux alarmes et aux points SCADA sont transmises.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>Environnement :<\/strong> La temp\u00e9rature, l'altitude, l'humidit\u00e9, la poussi\u00e8re, le sel, l'eau, le bruit et l'acc\u00e8s pour l'entretien sont v\u00e9rifi\u00e9s.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>S\u00e9curit\u00e9 :<\/strong> Des rapports sp\u00e9cifiques \u00e0 chaque mod\u00e8le et la matrice des codes applicables sont disponibles.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>Champ d'application :<\/strong> Les responsabilit\u00e9s du constructeur, de l'EPC, du propri\u00e9taire et du fournisseur d'\u00e9nergie sont attribu\u00e9es.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>Tests :<\/strong> Les proc\u00e9dures FAT, SAT et de test de capacit\u00e9 s'appuient sur des crit\u00e8res d'acceptation mesurables.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>Remise :<\/strong> Les sch\u00e9mas, les configurations, les micrologiciels, les manuels, les pi\u00e8ces de rechange, les formations et les conditions de garantie sont r\u00e9pertori\u00e9s.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-367ff8db auto-p elementor-widget elementor-widget-heading\" data-id=\"367ff8db\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">M\u00eame si la case \u201c non \u201d est coch\u00e9e sur la liste de contr\u00f4le, un montant budg\u00e9taire peut tout de m\u00eame \u00eatre autoris\u00e9. Cela devrait toutefois emp\u00eacher la validation finale du mod\u00e8le lorsque la valeur manquante est susceptible de modifier l'architecture, la garantie, l'interface \u00e9lectrique ou les conditions de r\u00e9ception.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-853cafe9 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"853cafe9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">De la conception \u00e0 un syst\u00e8me de stockage d'\u00e9nergie par batterie (BESS) C&amp;I disponible \u00e0 la vente<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-231ec995 auto-p elementor-widget elementor-widget-heading\" data-id=\"231ec995\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Ne commencez pas la conception en partant de la batterie la plus puissante que le budget permet. Partez d'une charge mesurable et d'une limite clairement d\u00e9finie. La puissance, en kVA, et l'\u00e9nergie sont calcul\u00e9es s\u00e9par\u00e9ment. Le PCC, les conditions du site, la logique de commande et les essais de r\u00e9ception sont ensuite \u00e9labor\u00e9s en fonction de cette charge.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-86fee031 auto-p elementor-widget elementor-widget-heading\" data-id=\"86fee031\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Ce processus permet au service des achats de disposer d'une comparaison solide. Une armoire moins ch\u00e8re qui ne comprend pas le compteur, le transformateur, l'\u00e9tude de protection, la mise en service ou la garantie d'\u00e9nergie utilisable ne constitue pas une offre \u00e9quivalente. Cette base de conception commune permet \u00e9galement \u00e0 l'EPC d'identifier les travaux de construction locaux avant l'arriv\u00e9e des \u00e9quipements.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2dea850a auto-p elementor-widget elementor-widget-heading\" data-id=\"2dea850a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Pour les applications compactes de type 400 V C&amp;I, une armoire ESSA constitue le premier choix logique lorsque ses limites en mati\u00e8re de puissance, d\u2019\u00e9nergie et d\u2019environnement correspondent aux exigences du projet. Un syst\u00e8me Energon \u00e0 refroidissement liquide convient \u00e0 des profils de temp\u00e9rature, de facteur de puissance ou de fonctionnement diff\u00e9rents, une fois que sa capacit\u00e9 en kW a \u00e9t\u00e9 confirm\u00e9e. Les projets de l'ordre du m\u00e9gawatt s'orientent vers les architectures ESSC ou 5000INTL lorsque leur tension et les interfaces du site correspondent aux principes de conception. Le choix final d\u00e9pend des donn\u00e9es v\u00e9rifi\u00e9es du site, et non de la gamme de produits.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-234458e3 auto-h3 elementor-widget elementor-widget-heading\" data-id=\"234458e3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Comparer les configurations du syst\u00e8me de stockage d'\u00e9nergie par batterie (BESS) MegSolid C&amp;I<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-383ffdf3 auto-p elementor-widget elementor-widget-heading\" data-id=\"383ffdf3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Fournissez les bases de conception et indiquez les valeurs qui sont encore provisoires. La comparaison pr\u00e9cisera l'orientation pr\u00e9liminaire concernant les \u00e9quipements, les hypoth\u00e8ses qui restent en suspens et les interfaces EPC qui doivent \u00eatre r\u00e9solues avant la validation.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1ee72cef elementor-tablet-align-center elementor-align-center auto-cta elementor-widget elementor-widget-button\" data-id=\"1ee72cef\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"#elementor-action%3Aaction%3Dpopup%3Aopen%26settings%3DeyJpZCI6Ijk0OCIsInRvZ2dsZSI6ZmFsc2V9\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Comparer les configurations BESS C&amp;I<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-bb0b3961 auto-faq e-flex e-con-boxed e-con e-child\" data-id=\"bb0b3961\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-2d3591d6 elementor-widget elementor-widget-heading\" data-id=\"2d3591d6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">FAQ<\/h2>\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-6da81892 e-con-full e-flex e-con e-child\" data-id=\"6da81892\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-9082ddcf elementor-widget elementor-widget-n-accordion\" data-id=\"9082ddcf\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;default_state&quot;:&quot;all_collapsed&quot;,&quot;max_items_expended&quot;:&quot;one&quot;,&quot;n_accordion_animation_duration&quot;:{&quot;unit&quot;:&quot;ms&quot;,&quot;size&quot;:400,&quot;sizes&quot;:[]}}\" data-widget_type=\"nested-accordion.default\">\n\t\t\t\t\t\t\t<div class=\"e-n-accordion\" aria-label=\"Accord\u00e9on. Ouvrez les liens \u00e0 l&#039;aide de la touche Entr\u00e9e ou de la barre d&#039;espace, fermez-les avec la touche \u00c9chap et naviguez \u00e0 l&#039;aide des touches fl\u00e9ch\u00e9es.\">\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2420\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"1\" tabindex=\"0\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2420\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> 1. Quelles informations sont n\u00e9cessaires pour lancer la conception d'un syst\u00e8me de stockage d'\u00e9nergie par batterie (BESS) C&amp;I ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2420\" class=\"elementor-element elementor-element-4caa3ae5 e-con-full e-flex e-con e-child\" data-id=\"4caa3ae5\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2420\" class=\"elementor-element elementor-element-3076421b e-con-full e-flex e-con e-child\" data-id=\"3076421b\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-7f9f3839 elementor-widget elementor-widget-heading\" data-id=\"7f9f3839\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Commencez par rassembler les donn\u00e9es relatives \u00e0 la charge par intervalles, le programme de charge prot\u00e9g\u00e9e, le sch\u00e9ma unifilaire, les donn\u00e9es concernant les transformateurs et les tableaux de distribution, la tension et le facteur de puissance sur site, les conditions environnementales, les informations relatives aux g\u00e9n\u00e9rateurs et aux installations photovolta\u00efques, ainsi que les modes de fonctionnement requis. L'\u00e9valuation pr\u00e9liminaire peut s'appuyer sur des hypoth\u00e8ses, mais chaque hypoth\u00e8se ayant une incidence sur le choix des produits doit \u00eatre signal\u00e9e en vue d'une confirmation ult\u00e9rieure.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2421\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"2\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2421\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> 2. Faut-il d'abord dimensionner un syst\u00e8me de stockage d'\u00e9nergie par batterie (BESS) en kW ou en kWh ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2421\" class=\"elementor-element elementor-element-06604c98 e-con-full e-flex e-con e-child\" data-id=\"06604c98\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2421\" class=\"elementor-element elementor-element-003c799b e-con-full e-flex e-con e-child\" data-id=\"003c799b\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-9b1e9d08 elementor-widget elementor-widget-heading\" data-id=\"9b1e9d08\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Ces deux param\u00e8tres sont indispensables et aucun ne remplace l'autre. Les valeurs en kW et en kVA d\u00e9terminent si le PCS est capable de supporter la charge et de g\u00e9rer la puissance r\u00e9active. La valeur en kWh d\u00e9termine la dur\u00e9e. V\u00e9rifiez les d\u00e9marrages transitoires et les conditions de surcharge s\u00e9par\u00e9ment de ces deux param\u00e8tres.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2422\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"3\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2422\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> 3. Quelle est la diff\u00e9rence entre le kW et le kVA dans la conception d'un syst\u00e8me de stockage d'\u00e9nergie par batterie (BESS) ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2422\" class=\"elementor-element elementor-element-dcf367c2 e-con-full e-flex e-con e-child\" data-id=\"dcf367c2\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2422\" class=\"elementor-element elementor-element-ad5fac8e e-con-full e-flex e-con e-child\" data-id=\"ad5fac8e\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c5ce749c elementor-widget elementor-widget-heading\" data-id=\"c5ce749c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Le kW correspond \u00e0 la puissance active fournie \u00e0 la charge. Le kVA correspond \u00e0 la puissance apparente et d\u00e9termine le courant alternatif \u00e0 une tension donn\u00e9e. Une charge n\u00e9cessitant 100 kW avec un facteur de puissance de 0,8 consomme 125 kVA, sans tenir compte d'aucune marge de conception suppl\u00e9mentaire ni d'aucune exigence relative aux transitoires.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2423\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"4\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2423\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> 4. La capacit\u00e9 nominale de la batterie en kWh peut-elle \u00eatre utilis\u00e9e comme autonomie de secours ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2423\" class=\"elementor-element elementor-element-c30778ba e-con-full e-flex e-con e-child\" data-id=\"c30778ba\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2423\" class=\"elementor-element elementor-element-2c7d2c05 e-con-full e-flex e-con e-child\" data-id=\"2c7d2c05\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-cc3c1493 elementor-widget elementor-widget-heading\" data-id=\"cc3c1493\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Non. L'autonomie d\u00e9pend de la plage de SOC utilisable, des pertes de conversion en courant alternatif, de la consommation des \u00e9quipements auxiliaires, de la puissance de d\u00e9charge, de la temp\u00e9rature, des limites de tension et de la capacit\u00e9 requise en fin de vie. Utilisez l'\u00e9nergie CA utilisable garantie lorsqu'elle est disponible et veillez \u00e0 ce que les limites de mesure restent coh\u00e9rentes.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2424\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"5\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2424\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> 5. Comment calcule-t-on la puissance de lissage des pics ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2424\" class=\"elementor-element elementor-element-a2fc76ff e-con-full e-flex e-con e-child\" data-id=\"a2fc76ff\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2424\" class=\"elementor-element elementor-element-b0574938 e-con-full e-flex e-con e-child\" data-id=\"b0574938\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-b1545e3a elementor-widget elementor-widget-heading\" data-id=\"b1545e3a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Soustrayez l'objectif d'importation convenu de la demande mesur\u00e9e sur site au niveau du PCC, puis v\u00e9rifiez l'intervalle de comptage, les pics les plus rapides, la latence de contr\u00f4le, la part de puissance r\u00e9active et la marge. Le contr\u00f4leur doit \u00e9galement disposer d'un SOC suffisant au moment o\u00f9 le pic se produit.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2425\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"6\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2425\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> 6. Pourquoi la recharge des syst\u00e8mes de stockage d'\u00e9nergie par batterie (BESS) peut-elle g\u00e9n\u00e9rer un nouveau pic de demande ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2425\" class=\"elementor-element elementor-element-86561926 e-con-full e-flex e-con e-child\" data-id=\"86561926\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2425\" class=\"elementor-element elementor-element-76d8f523 e-con-full e-flex e-con e-child\" data-id=\"76d8f523\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-3509bc6c elementor-widget elementor-widget-heading\" data-id=\"3509bc6c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">La recharge vient s'ajouter \u00e0 l'importation du site. Si le point de consigne de r\u00e9cup\u00e9ration ne tient pas compte de la demande simultan\u00e9e de l'installation, la charge combin\u00e9e peut d\u00e9passer l'objectif de demande. Calculez la puissance de recharge autoris\u00e9e \u00e0 partir de la limite de soutirage, de la demande r\u00e9elle de l'installation et d'une marge technique.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2426\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"7\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2426\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> 7. Un PCS de 125 kVA fournit-il 125 kW ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2426\" class=\"elementor-element elementor-element-7bfd8789 e-con-full e-flex e-con e-child\" data-id=\"7bfd8789\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2426\" class=\"elementor-element elementor-element-a5faf26b e-con-full e-flex e-con e-child\" data-id=\"a5faf26b\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-3393c2eb elementor-widget elementor-widget-heading\" data-id=\"3393c2eb\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Uniquement avec un facteur de puissance unitaire et dans le respect de toutes les autres limites de fonctionnement. Avec un facteur de puissance de 0,8, 125 kVA correspondent \u00e0 100 kW. Utilisez le facteur de puissance pr\u00e9vu pour le projet et la courbe de capacit\u00e9 du PCS r\u00e9gul\u00e9.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2427\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"8\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2427\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> 8. Un syst\u00e8me de stockage d'\u00e9nergie par batterie (BESS) de 400 V peut-il \u00eatre raccord\u00e9 directement \u00e0 un tableau \u00e9lectrique existant ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2427\" class=\"elementor-element elementor-element-fa5ad786 e-con-full e-flex e-con e-child\" data-id=\"fa5ad786\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2427\" class=\"elementor-element elementor-element-cbb0a3eb e-con-full e-flex e-con e-child\" data-id=\"cbb0a3eb\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-574c5e94 elementor-widget elementor-widget-heading\" data-id=\"574c5e94\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Ce n'est qu'apr\u00e8s avoir v\u00e9rifi\u00e9 les caract\u00e9ristiques nominales des bus et des disjoncteurs, la r\u00e9sistance aux courts-circuits, la coordination des protections, la capacit\u00e9 des c\u00e2bles, la mise \u00e0 la terre, la disposition des voies de secours et les exigences de l'autorit\u00e9 de raccordement. La correspondance de la tension nominale est n\u00e9cessaire mais non suffisante.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2428\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"9\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2428\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> 9. O\u00f9 faut-il installer le compteur PCC et les transformateurs de courant ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2428\" class=\"elementor-element elementor-element-0b059a6c e-con-full e-flex e-con e-child\" data-id=\"0b059a6c\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2428\" class=\"elementor-element elementor-element-18d6791e e-con-full e-flex e-con e-child\" data-id=\"18d6791e\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-938509f4 elementor-widget elementor-widget-heading\" data-id=\"938509f4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Ils doivent \u00eatre install\u00e9s au niveau de la limite du r\u00e9seau \u00e9lectrique que le syst\u00e8me de stockage d'\u00e9nergie par batterie (BESS) est cens\u00e9 r\u00e9guler. Le rapport de transformation, la classe, la charge, la polarit\u00e9 et le chemin de communication du transformateur de courant doivent permettre d'atteindre la pr\u00e9cision et le temps de r\u00e9ponse requis. L'emplacement doit figurer sur le sch\u00e9ma unifilaire approuv\u00e9.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2429\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"10\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2429\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> 10. Une armoire de protection IP54 est-elle automatiquement adapt\u00e9e \u00e0 une utilisation en ext\u00e9rieur ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2429\" class=\"elementor-element elementor-element-d452aaeb e-con-full e-flex e-con e-child\" data-id=\"d452aaeb\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2429\" class=\"elementor-element elementor-element-dc9f09de e-con-full e-flex e-con e-child\" data-id=\"dc9f09de\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-3ddb12d5 elementor-widget elementor-widget-heading\" data-id=\"3ddb12d5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Non. La norme IP54 d\u00e9finit un niveau pr\u00e9cis de protection contre les infiltrations. Elle ne pr\u00e9cise pas la capacit\u00e9 de fonctionnement \u00e0 pleine puissance \u00e0 des temp\u00e9ratures \u00e9lev\u00e9es ou en altitude, le contr\u00f4le de la condensation, la r\u00e9sistance au brouillard salin, la conformit\u00e9 acoustique, la protection contre les inondations ni la fr\u00e9quence d'entretien requise pour les filtres.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-24210\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"11\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-24210\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> 11. Quelle est la diff\u00e9rence entre FAT et SAT pour un BESS ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-24210\" class=\"elementor-element elementor-element-fb036fad e-con-full e-flex e-con e-child\" data-id=\"fb036fad\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-24210\" class=\"elementor-element elementor-element-5b80a7ef e-con-full e-flex e-con e-child\" data-id=\"5b80a7ef\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-fb821187 elementor-widget elementor-widget-heading\" data-id=\"fb821187\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Le contr\u00f4le FAT permet de v\u00e9rifier l'\u00e9quipement fabriqu\u00e9, la configuration document\u00e9e et la logique testable en usine avant l'exp\u00e9dition. Le contr\u00f4le SAT permet de v\u00e9rifier, sur le site du projet, le c\u00e2blage sp\u00e9cifique \u00e0 l'installation, les compteurs, les disjoncteurs, les dispositifs de protection, les syst\u00e8mes de communication et les s\u00e9quences de fonctionnement.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-24211\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"12\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-24211\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> 12. Qui est charg\u00e9 de l'installation du BESS ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-24211\" class=\"elementor-element elementor-element-74a8f2b9 e-con-full e-flex e-con e-child\" data-id=\"74a8f2b9\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-24211\" class=\"elementor-element elementor-element-1b00895e e-con-full e-flex e-con e-child\" data-id=\"1b00895e\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-4c68bdf6 elementor-widget elementor-widget-heading\" data-id=\"4c68bdf6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Le contrat sign\u00e9 fait foi. Dans le cadre d'un accord type de fourniture d'\u00e9quipements, le fabricant fournit le syst\u00e8me de stockage d'\u00e9nergie par batterie (BESS), les documents d'interface r\u00e9glement\u00e9s et l'assistance convenue pour les essais d'acceptation en usine (FAT). L'EPC local se charge des travaux de g\u00e9nie civil, de l'appareillage de commutation, du c\u00e2blage, des autorisations, de l'installation sur site et de l'ing\u00e9nierie locale, ainsi que des activit\u00e9s conjointes d'essais d'acceptation sur site (SAT) et de remise des travaux.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-24212\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"13\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-24212\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> 13. Comment comparer les solutions ESSA, Energon et les syst\u00e8mes de stockage d'\u00e9nergie par batterie (BESS) en conteneurs ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-24212\" class=\"elementor-element elementor-element-693fbdbb e-con-full e-flex e-con e-child\" data-id=\"693fbdbb\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-24212\" class=\"elementor-element elementor-element-95c65912 e-con-full e-flex e-con e-child\" data-id=\"95c65912\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-207c8bd3 elementor-widget elementor-widget-heading\" data-id=\"207c8bd3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Comparer la puissance garantie aux conditions de temp\u00e9rature, d\u2019altitude et de facteur de puissance sp\u00e9cifiques au projet ; l\u2019\u00e9nergie CA utilisable ; l\u2019architecture de tension ; le refroidissement ; les limites environnementales ; les protections et les commandes ; l\u2019\u00e9tendue des travaux d\u2019installation ; les justificatifs de r\u00e9ception et les exigences de maintenance tout au long du cycle de vie. Le kWh nominal ne suffit pas \u00e0 lui seul \u00e0 \u00e9tablir l\u2019\u00e9quivalence.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Une m\u00e9thode d'ing\u00e9nierie pratique permettant de convertir les donn\u00e9es de charge C&amp;I, les objectifs d'exploitation et les contraintes du site en une puissance nominale v\u00e9rifiable du syst\u00e8me de stockage d'\u00e9nergie par batterie (BESS), en une capacit\u00e9 de batterie, en une interface \u00e9lectrique, en un p\u00e9rim\u00e8tre de contr\u00f4le et en un plan de r\u00e9ception.<\/p>","protected":false},"author":4,"featured_media":5147,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"_joinchat":[],"footnotes":""},"categories":[1,714],"tags":[517,521,224,518,519,520,316,36,484,363],"class_list":["post-5150","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-bess","category-ci-battery-storage-solutions","tag-battery-energy-storage-system-design","tag-battery-sizing","tag-bess-commissioning","tag-bess-design","tag-bess-epc","tag-bess-installation","tag-ci-bess","tag-MegSolid","tag-pcc-control","tag-pcs-sizing"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/posts\/5150","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/comments?post=5150"}],"version-history":[{"count":4,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/posts\/5150\/revisions"}],"predecessor-version":[{"id":5154,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/posts\/5150\/revisions\/5154"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/media\/5147"}],"wp:attachment":[{"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/media?parent=5150"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/categories?post=5150"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/tags?post=5150"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}