{"id":5185,"date":"2026-09-03T09:33:12","date_gmt":"2026-09-03T01:33:12","guid":{"rendered":"https:\/\/www.solidess.com\/?p=5185"},"modified":"2026-09-03T09:33:12","modified_gmt":"2026-09-03T01:33:12","slug":"liste-de-controle-pour-le-test-dacceptation-du-site-bess","status":"publish","type":"post","link":"https:\/\/www.solidess.com\/fr\/bess-site-acceptance-test-checklist\/","title":{"rendered":"Liste de contr\u00f4le pour les essais de r\u00e9ception du site BESS C&amp;I avant la remise des cl\u00e9s"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"5185\" class=\"elementor elementor-5185\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-bf4793c e-con-full auto-article-root e-flex e-con e-parent\" data-id=\"bf4793c\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-7ff88fa3 auto-p elementor-widget elementor-widget-heading\" data-id=\"7ff88fa3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Au Cape Town Market d'Epping, une batterie d'une capacit\u00e9 de 3 MWh a \u00e9t\u00e9 mise en service apr\u00e8s l'installation de plus de 3 000 panneaux solaires sur l'ensemble du site. Cette batterie n'\u00e9tait plus un simple \u00e9quipement d'usine sur une plate-forme d'essai. Elle faisait d\u00e9sormais partie int\u00e9grante d'un march\u00e9 en activit\u00e9, avec des syst\u00e8mes de r\u00e9frig\u00e9ration, des charges du site et des dispositifs de gestion de la demande connect\u00e9s \u00e0 celle-ci, comme l'indique le <a href=\"https:\/\/www.capetown.gov.za\/Media-and-news\/Cape%20Town%20Market%20goes%20greener%20than%20ever%20-%20inside%20and%20on%20top\" target=\"_blank\" rel=\"noopener\" style=\"color:#61CE70\">Annonce d'un projet de la Ville du Cap<\/a>.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-586cfc73 auto-p elementor-widget elementor-widget-heading\" data-id=\"586cfc73\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">C'est pr\u00e9cis\u00e9ment pour tenir compte de ce changement de contexte que le SAT a \u00e9t\u00e9 cr\u00e9\u00e9. Au sein du <strong><a href=\"https:\/\/www.solidess.com\/fr\/ci-bess-testing-fat-sat-performance-acceptance\/\" target=\"_blank\" style=\"color:#61ce70\">S\u00e9quence de test et de r\u00e9ception du syst\u00e8me BESS C&amp;I<\/a><\/strong>, il v\u00e9rifie le c\u00e2blage, les dispositifs de protection, les communications et le comportement des syst\u00e8mes de contr\u00f4le, qui ne sont op\u00e9rationnels qu'apr\u00e8s l'installation. Une validation SAT permet de mettre en service certaines fonctions du site ; elle ne garantit pas pour autant la production effective de kWh en courant alternatif ni la disponibilit\u00e9 \u00e0 long terme.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2f8fdad7 auto-p elementor-widget elementor-widget-heading\" data-id=\"2f8fdad7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">La m\u00eame limite s'applique \u00e0 une tension de 400 V <strong><a href=\"https:\/\/www.solidess.com\/fr\/product\/systeme-de-stockage-denergie-en-armoire-exterieure\/\" target=\"_blank\" style=\"color:#61ce70\">MegSolid ESSA0100B-0215<\/a><\/strong>. Le dossier d'usine accompagne l'armoire jusqu'au chantier, tandis que le circuit d'alimentation final, le tableau de distribution, les transformateurs de courant, le compteur et le r\u00e9seau sont mis en service via le <strong><a href=\"https:\/\/www.solidess.com\/fr\/connexion-de-batterie-400-v-au-tableau-electrique-existant\/\" target=\"_blank\" style=\"color:#61ce70\">raccordement \u00e0 400 V install\u00e9<\/a><\/strong>.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d6f46607 auto-image elementor-widget elementor-widget-image\" data-id=\"d6f46607\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"700\" height=\"700\" src=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/BESS-Site-Acceptance-Test-Before-Handover.png\" class=\"attachment-1536x1536 size-1536x1536 wp-image-5182\" alt=\"Le MegSolid ESSA0100B-0215 fait l&#039;objet d&#039;un essai de r\u00e9ception sur site BESS sur un site industriel \u00e0 Epping, au Cap.\" srcset=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/BESS-Site-Acceptance-Test-Before-Handover.png 700w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/BESS-Site-Acceptance-Test-Before-Handover-300x300.png 300w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/BESS-Site-Acceptance-Test-Before-Handover-150x150.png 150w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/BESS-Site-Acceptance-Test-Before-Handover-12x12.png 12w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/BESS-Site-Acceptance-Test-Before-Handover-600x600.png 600w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/BESS-Site-Acceptance-Test-Before-Handover-100x100.png 100w\" sizes=\"(max-width: 700px) 100vw, 700px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0bfd695a auto-h2 elementor-widget elementor-widget-heading\" data-id=\"0bfd695a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Ce que la r\u00e9ussite au SAT implique r\u00e9ellement<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ea4d804c auto-p elementor-widget elementor-widget-heading\" data-id=\"ea4d804c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Le SAT ne se r\u00e9sume pas \u00e0 une simple coche verte. Un projet parvient g\u00e9n\u00e9ralement \u00e0 la mise en service sur site par \u00e9tapes, car une installation peut \u00eatre mise sous tension en toute s\u00e9curit\u00e9 avant d'\u00eatre pr\u00eate pour l'\u00e9cr\u00eatement automatique des pics, le basculement vers la source de secours ou le fonctionnement sans surveillance.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f3c94a06 auto-table elementor-widget elementor-widget-text-editor\" data-id=\"f3c94a06\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"cea-table-wrap\"><table><thead><tr><th>Point de largage<\/th><th>Justificatifs requis<\/th><th>Ce qui pourrait suivre<\/th><th>Ce qui reste en suspens<\/th><\/tr><\/thead><tbody><tr><td>Installation termin\u00e9e<\/td><td>Plans approuv\u00e9s, identification des \u00e9quipements, registres relatifs aux c\u00e2bles et \u00e0 la mise \u00e0 la terre, inspection m\u00e9canique<\/td><td>Contr\u00f4les de pr\u00e9-mise sous tension contr\u00f4l\u00e9s<\/td><td>Protection en service, communications et modes de fonctionnement<\/td><\/tr><tr><td>Mise sous tension sans danger<\/td><td>R\u00e9sultats des tests d'isolation et de continuit\u00e9, param\u00e8tres de protection, parcours d'arr\u00eat d'urgence, alimentations auxiliaires<\/td><td>Mise sous tension et d\u00e9marrage contr\u00f4l\u00e9s<\/td><td>Contr\u00f4le du site en boucle ferm\u00e9e et engagement de performance<\/td><\/tr><tr><td>SAT fonctionnel termin\u00e9<\/td><td>Mesure, verrouillages, alarmes, communications, responsabilit\u00e9 des commandes et r\u00e9ponse en fonction du mode<\/td><td>Modes de fonctionnement autoris\u00e9s dans les limites indiqu\u00e9es<\/td><td>Les r\u00e9sultats relatifs \u00e0 l'\u00e9nergie utile, \u00e0 la qualit\u00e9 de l'alimentation \u00e9lectrique ou \u00e0 l'autonomie ne sont pas inclus dans le SAT<\/td><\/tr><tr><td>Communiqu\u00e9 de transfert<\/td><td>Fiches SAT sign\u00e9es, d\u00e9fauts de blocage corrig\u00e9s, logiciels et param\u00e8tres valid\u00e9s, registres des op\u00e9rateurs<\/td><td>Fonctionnement selon la configuration valid\u00e9e<\/td><td>Tout essai de performance ou de fiabilit\u00e9 report\u00e9 pr\u00e9vu dans le contrat<\/td><\/tr><\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c64aa21f auto-image elementor-widget elementor-widget-image\" data-id=\"c64aa21f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"900\" height=\"675\" src=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/BESS-SAT-Release-Path.png\" class=\"attachment-1536x1536 size-1536x1536 wp-image-5183\" alt=\"Parcours de mise en service du BESS SAT, depuis la fin de l&#039;installation et la mise sous tension en toute s\u00e9curit\u00e9 jusqu&#039;aux essais fonctionnels et \u00e0 la remise au client\" srcset=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/BESS-SAT-Release-Path.png 900w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/BESS-SAT-Release-Path-300x225.png 300w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/BESS-SAT-Release-Path-768x576.png 768w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/BESS-SAT-Release-Path-16x12.png 16w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/BESS-SAT-Release-Path-600x450.png 600w\" sizes=\"(max-width: 900px) 100vw, 900px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7fcf622f auto-p elementor-widget elementor-widget-heading\" data-id=\"7fcf622f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">La signature doit pr\u00e9ciser le stade de mise en service. La mention \u201c SAT PASS \u201d ne permet pas \u00e0 elle seule de savoir si la centrale est simplement sous tension, pr\u00eate \u00e0 fonctionner sous surveillance ou autoris\u00e9e \u00e0 \u00eatre exploit\u00e9e en mode automatique \u00e0 des fins commerciales.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-71fb52ea auto-p elementor-widget elementor-widget-heading\" data-id=\"71fb52ea\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Cette distinction est conforme aux pratiques en mati\u00e8re de tests ind\u00e9pendants. <a href=\"https:\/\/www.tuvsud.com\/en\/industries\/manufacturing\/battery-energy-storage-system\" target=\"_blank\" rel=\"noopener\" style=\"color:#61CE70\">T\u00dcV S\u00dcD pr\u00e9sente le SAT<\/a> afin de v\u00e9rifier que l'\u00e9quipement BESS install\u00e9 est complet, int\u00e9gr\u00e9 et pr\u00eat \u00e0 fonctionner en toute s\u00e9curit\u00e9 sur le site, les essais de performance \u00e9tant consid\u00e9r\u00e9s comme une activit\u00e9 distincte et clairement d\u00e9finie. <a href=\"https:\/\/webstore.iec.ch\/en\/publication\/75427\" target=\"_blank\" rel=\"noopener\" style=\"color:#61CE70\">IEC 62933-3-1:2025<\/a> couvre \u00e9galement les fonctions, le fonctionnement, la surveillance, les \u00e9l\u00e9ments de test et l'\u00e9valuation des performances du syst\u00e8me EES. La proc\u00e9dure du projet d\u00e9finit toujours les valeurs de r\u00e9ussite effectives.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0a7023cf auto-h2 elementor-widget elementor-widget-heading\" data-id=\"0a7023cf\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Interrompre l'op\u00e9ration avant la mise sous tension en cas de divergence entre les registres<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e6c871dd auto-p elementor-widget elementor-widget-heading\" data-id=\"e6c871dd\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Une \u00e9quipe d'installation peut avoir achev\u00e9 le c\u00e2blage visible, mais laisser tout de m\u00eame \u00e0 l'\u00e9quipe de mise en service une installation qui ne correspond pas aux sp\u00e9cifications. La cause la plus fr\u00e9quente n'est pas un dommage important sur les \u00e9quipements, mais un d\u00e9calage discret entre le sch\u00e9ma approuv\u00e9, la configuration livr\u00e9e et le raccordement final sur site.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-977cb153 auto-p elementor-widget elementor-widget-heading\" data-id=\"977cb153\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Imaginons qu'une armoire ESSA soit ajout\u00e9e \u00e0 un tableau \u00e9lectrique d'usine existant. Le plan de construction indique que le compteur PCC est situ\u00e9 en amont du circuit d'alimentation du BESS. Or, le compteur install\u00e9 se trouve sur le circuit d'alimentation lui-m\u00eame. Les deux compteurs fournissent des chiffres plausibles, mais un seul d'entre eux peut indiquer l'importation totale du site. Mettre l'armoire sous tension peut \u00eatre sans danger ; en revanche, d\u00e9clencher le syst\u00e8me de r\u00e9duction des pics \u00e0 partir de ce signal ne l'est pas.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9eff6fb1 auto-p elementor-widget elementor-widget-heading\" data-id=\"9eff6fb1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">La visite de contr\u00f4le avant mise sous tension doit permettre de v\u00e9rifier six points :<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8a3d6fe9 elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"8a3d6fe9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>Identit\u00e9 :<\/strong> mod\u00e8le du bo\u00eetier, num\u00e9ro de s\u00e9rie, PCS, BMS, EMS et versions logicielles approuv\u00e9es ;<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>Sch\u00e9ma \u00e9lectrique tel que r\u00e9alis\u00e9 :<\/strong> source, transformateur, tableau de distribution, ligne d'alimentation, disjoncteur, c\u00e2ble, disposition du neutre et du conducteur de protection ;<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>Ach\u00e8vement m\u00e9canique :<\/strong> fixation, d\u00e9gagements, presse-\u00e9toupes, fonctionnement des portes, circuit de ventilation et dommages li\u00e9s au transport ;<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>R\u00e9alisation des travaux \u00e9lectriques :<\/strong> raccordement des c\u00e2bles, enregistrement du couple de serrage, ordre des phases, continuit\u00e9, isolation et mise \u00e0 la terre ;<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>Base de couverture :<\/strong> les r\u00e9glages des relais et des disjoncteurs, le chemin de d\u00e9clenchement, les hypoth\u00e8ses de s\u00e9lectivit\u00e9 et les autorisations \u00e0 distance ;<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>\u00c9tat de pr\u00e9paration des services auxiliaires :<\/strong> l'alimentation \u00e9lectrique, les syst\u00e8mes de chauffage, de ventilation et de climatisation (CVC) ou l'alimentation des ventilateurs, l'\u00e9clairage, les syst\u00e8mes de communication et toute interface avec les syst\u00e8mes de lutte contre l'incendie entrant dans le champ d'application.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b760b0fb auto-p elementor-widget elementor-widget-heading\" data-id=\"b760b0fb\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Certains probl\u00e8mes peuvent rester sur la liste des points \u00e0 r\u00e9gler. D'autres n\u00e9cessitent l'arr\u00eat de l'alimentation \u00e9lectrique.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e5b73e7a auto-table elementor-widget elementor-widget-text-editor\" data-id=\"e5b73e7a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"cea-table-wrap\"><table><thead><tr><th>Conclusion<\/th><th>Configuration type avant mise sous tension<\/th><\/tr><\/thead><tbody><tr><td>\u00c9tiquette manquante sur un c\u00e2ble interne non essentiel<\/td><td>Enregistrer et cl\u00f4turer \u00e0 la date convenue si l'identification reste sans ambigu\u00eft\u00e9<\/td><\/tr><tr><td>Les dimensions r\u00e9elles de la ligne d'alimentation diff\u00e8rent de celles pr\u00e9vues dans les plans approuv\u00e9s<\/td><td>Ne pas mettre sous tension tant que la capacit\u00e9 de charge, les dispositifs de protection et la r\u00e9vision des sch\u00e9mas n'ont pas \u00e9t\u00e9 accept\u00e9s<\/td><\/tr><tr><td>Le fichier de param\u00e8tres de protection ne comporte aucune r\u00e9vision approuv\u00e9e<\/td><td>Ne pas activer la mise sous tension ; les captures d'\u00e9cran ne constituent pas un enregistrement des param\u00e8tres contr\u00f4l\u00e9s<\/td><\/tr><tr><td>Le num\u00e9ro de s\u00e9rie du bo\u00eetier diff\u00e8re de celui indiqu\u00e9 dans la fiche de mise en production du FAT<\/td><td>V\u00e9rifiez que le nombre d'unit\u00e9s livr\u00e9es correspond bien \u00e0 celui figurant dans le registre d'usine avant de poursuivre.<\/td><\/tr><tr><td>L'emplacement du compteur PCC diff\u00e8re de celui indiqu\u00e9 sur le plan de r\u00e9f\u00e9rence<\/td><td>Maintenir les modes de contr\u00f4le automatique jusqu\u2019\u00e0 ce que les limites de mesure soient corrig\u00e9es ou officiellement red\u00e9finies<\/td><\/tr><\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4ab9dc5b auto-p elementor-widget elementor-widget-heading\" data-id=\"4ab9dc5b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Il ne s'agit pas de faire de chaque d\u00e9tail esth\u00e9tique une crise. Il s'agit d'\u00e9viter qu'une modification de conception ou de s\u00e9curit\u00e9 ne passe inaper\u00e7ue parmi les retouches de peinture et les corrections d'\u00e9tiquettes.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-00363aab auto-h2 elementor-widget elementor-widget-heading\" data-id=\"00363aab\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">La premi\u00e8re commande en direct doit \u00eatre ennuyeuse<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c29192c0 auto-p elementor-widget elementor-widget-heading\" data-id=\"c29192c0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Une commande \u00e0 pleine puissance ne constitue pas une bonne premi\u00e8re v\u00e9rification. Un SAT \u00ab propre \u00bb commence par la commande la plus modeste permettant de confirmer la direction, le retour d\u2019information et la ma\u00eetrise du syst\u00e8me, sans contraindre l\u2019installation \u00e0 une r\u00e9cup\u00e9ration difficile.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-898e1775 auto-p elementor-widget elementor-widget-heading\" data-id=\"898e1775\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Voici un ordre possible :<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b3d700ef elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"b3d700ef\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">1. Mettre sous tension les circuits auxiliaires et de commande en bloquant l'\u00e9tage de puissance.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">2. V\u00e9rifier que les \u00e9tats des syst\u00e8mes BMS, PCS et EMS sont corrects en les comparant \u00e0 la liste des points approuv\u00e9s.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">3. Tester les arr\u00eats d'urgence locaux et \u00e0 distance, les autorisations de d\u00e9clenchement des disjoncteurs et les conditions de r\u00e9armement.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">4. Activer l'\u00e9tage de puissance et \u00e9mettre une commande de charge \u00e0 faible puissance.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">5. Revenez \u00e0 z\u00e9ro, puis lancez une commande de d\u00e9charge \u00e0 faible puissance.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">6. Comparer la commande, la r\u00e9ponse du PCS, la mesure du courant alternatif de l'armoire et le r\u00e9sultat du PCC sur une m\u00eame base de temps.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">7. N'augmenter la puissance qu'une fois que le sens de rotation, la correspondance des phases, les limites et les verrouillages sont tous valid\u00e9s.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f2c83c0c auto-p elementor-widget elementor-widget-heading\" data-id=\"f2c83c0c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Une commande de 10 kW suffit souvent \u00e0 mettre en \u00e9vidence un signe invers\u00e9 ou une phase inactive sur une armoire de 100 kW, mais cette valeur de 10 kW n'est qu'un exemple de point de test et non une valeur d'acceptation universelle. La proc\u00e9dure approuv\u00e9e doit tenir compte de la r\u00e9solution du compteur, des variations de charge de l'installation et du point de fonctionnement stable le plus bas.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b4baf477 auto-p elementor-widget elementor-widget-heading\" data-id=\"b4baf477\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Si une d\u00e9charge est ordonn\u00e9e et que l'importation vers le r\u00e9seau augmente, ne continuez pas \u00e0 augmenter la puissance pour \u201c rendre la tendance plus claire \u201d. Interrompez l'essai et examinez la cha\u00eene de mesure install\u00e9e. Le prochain article de la s\u00e9rie traite en d\u00e9tail de la polarit\u00e9 des transformateurs de courant, de leur rapport de transformation, de la convention des signes et de l'alignement temporel ; la fiche SAT doit simplement indiquer que la boucle a \u00e9t\u00e9 v\u00e9rifi\u00e9e et pr\u00e9ciser o\u00f9 sont conserv\u00e9es les preuves.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f299adf5 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"f299adf5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">D\u00e9montrer \u00e0 qui appartient chaque commande<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-bdc3a618 auto-p elementor-widget elementor-widget-heading\" data-id=\"bdc3a618\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Sur site, plusieurs appareils peuvent envoyer des instructions diff\u00e9rentes \u00e0 la batterie. Une IHM locale peut maintenir un point de consigne manuel alors que le syst\u00e8me de gestion de l'\u00e9nergie (EMS) tente de r\u00e9duire un pic de consommation. Le syst\u00e8me SCADA peut afficher une commande verte m\u00eame si le syst\u00e8me de contr\u00f4le de puissance (PCS) l'a rejet\u00e9e en raison d'une limite active du syst\u00e8me de gestion de la batterie (BMS). Le SAT doit rendre cette hi\u00e9rarchie visible.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-67f873fa auto-table elementor-widget elementor-widget-text-editor\" data-id=\"67f873fa\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"cea-table-wrap\"><table><thead><tr><th>Conditions d'exploitation<\/th><th>Propri\u00e9taire pr\u00e9vu de la commande<\/th><th>\u00c9l\u00e9ments de preuve \u00e0 conserver<\/th><th>R\u00e9ponse requise en cas d'\u00e9chec de la saisie<\/th><\/tr><\/thead><tbody><tr><td>Maintenance locale<\/td><td>Contr\u00f4le local autoris\u00e9<\/td><td>\u00c9tat du mode, consigne locale, bloc de commande \u00e0 distance<\/td><td>Rester dans les limites de protection locales<\/td><\/tr><tr><td>\u00c9galisation de la charge<\/td><td>Syst\u00e8me de surveillance environnementale (EMS) sur site utilisant le compteur PCC homologu\u00e9<\/td><td>Demande PCC, objectif, commande BESS et puissance r\u00e9elle<\/td><td>D\u00e9clencher une alerte et basculer vers la solution de secours approuv\u00e9e lorsque les donn\u00e9es du compteur sont obsol\u00e8tes<\/td><\/tr><tr><td>Pr\u00e9l\u00e8vement programm\u00e9<\/td><td>EMS ou planificateur agr\u00e9\u00e9<\/td><td>Programme, source de temps, limite SOC et commande de charge<\/td><td>Bloquer ou limiter la facturation si le calendrier ou la limite d'importation n'est pas valide<\/td><\/tr><tr><td>\u00c9tat de pr\u00e9paration \u00e0 la sauvegarde<\/td><td>Logique de r\u00e9serve du BMS\/EMS et sch\u00e9ma de transfert entre sites<\/td><td>R\u00e9serve du SOC, \u00e9tat du r\u00e9seau, \u00e9tat des disjoncteurs et \u00e9tat de la charge<\/td><td>Maintenir la r\u00e9serve d\u00e9finie et respecter l'ordre de transfert approuv\u00e9<\/td><\/tr><tr><td>Situation d'urgence<\/td><td>Protection locale et cha\u00eene de s\u00e9curit\u00e9 c\u00e2bl\u00e9e<\/td><td>\u00c9v\u00e9nement d\u00e9clencheur, trajectoire de d\u00e9placement, \u00e9tat du disjoncteur et enregistrement de r\u00e9initialisation<\/td><td>Commande de coupure d'alimentation et blocage du red\u00e9marrage automatique jusqu'\u00e0 ce que les conditions de d\u00e9blocage soient remplies<\/td><\/tr><\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-414514e8 auto-p elementor-widget elementor-widget-heading\" data-id=\"414514e8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Le <strong><a href=\"https:\/\/www.solidess.com\/fr\/architecture-de-communication-bms-ems-dans-un-bess\/\" target=\"_blank\" style=\"color:#61ce70\">Limite de communication entre le BMS et l'EMS<\/a><\/strong> explique pourquoi les limites de protection restent locales m\u00eame lorsque le contr\u00f4leur de supervision g\u00e8re le point de consigne commercial. Pour les modes de fonctionnement pilot\u00e9s par les compteurs, le <strong><a href=\"https:\/\/www.solidess.com\/fr\/comment-specifier-un-controle-de-zero-injection-au-pcc-pour-un-systeme-de-stockage-denergie-par-batterie-bess\/\" target=\"_blank\" style=\"color:#61ce70\">Cadre de contr\u00f4le PCC<\/a><\/strong> indique quels signal, base de temps et \u00e9tat de secours doivent \u00eatre d\u00e9finis avant le fonctionnement automatique.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-090079ea auto-p elementor-widget elementor-widget-heading\" data-id=\"090079ea\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Lorsque l'armoire, le tableau de distribution et le syst\u00e8me de gestion des installations (EMS) du site rel\u00e8vent de p\u00e9rim\u00e8tres diff\u00e9rents, un bref examen des interfaces permet de d\u00e9terminer o\u00f9 s'arr\u00eatent les \u00e9quipements MegSolid et o\u00f9 commencent les travaux SAT sous la responsabilit\u00e9 de l'EPC.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-60c48f53 elementor-tablet-align-center elementor-align-center auto-cta elementor-widget elementor-widget-button\" data-id=\"60c48f53\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"#elementor-action%3Aaction%3Dpopup%3Aopen%26settings%3DeyJpZCI6Ijk0OCIsInRvZ2dsZSI6ZmFsc2V9\" target=\"_blank\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Contactez MegSolid pour en savoir plus sur l'int\u00e9gration du syst\u00e8me de stockage d'\u00e9nergie par batterie C&amp;I<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-15191186 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"15191186\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Exemple d'ESSA SAT \u00e0 400 V<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2be9ee8f auto-p elementor-widget elementor-widget-heading\" data-id=\"2be9ee8f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Une usine installe un ESSA0100B-0215 destin\u00e9 \u00e0 une application de lissage de pointe de 80 kW sur un tableau principal existant de 400 V. La puissance nominale en courant alternatif de 100 kW et l'\u00e9nergie nominale de 215,04 kWh indiqu\u00e9es pour l'armoire la classent dans la bonne cat\u00e9gorie pr\u00e9liminaire. Ces valeurs ne prouvent toutefois pas que le site puisse fournir 80 kW en continu ni qu'une quantit\u00e9 donn\u00e9e d'\u00e9nergie en courant alternatif atteindra le point de raccordement au r\u00e9seau (PCC).<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-cb93b3f9 auto-p elementor-widget elementor-widget-heading\" data-id=\"cb93b3f9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Le matin du samedi, les donn\u00e9es suivantes concordent :<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-30b883ad elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"30b883ad\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">le mod\u00e8le et le num\u00e9ro de s\u00e9rie du meuble correspondent \u00e0 la fiche technique d'usine ;<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">les versions des logiciels install\u00e9s correspondent \u00e0 la version approuv\u00e9e ou \u00e0 un enregistrement de modification sur site accept\u00e9 ;<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">le c\u00e2ble d'alimentation, le disjoncteur et les r\u00e9glages de protection correspondent au sch\u00e9ma unifilaire d'ex\u00e9cution ;<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">le compteur PCC est situ\u00e9 en amont des charges du site et de la ligne d'alimentation du BESS, conform\u00e9ment \u00e0 la logique d'\u00e9cr\u00eatement des pics ;<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">l'ordre des phases du tableau de distribution, ainsi que la disposition du neutre et du conducteur de protection (PE), correspondent \u00e0 l'interface de l'armoire ;<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">l'op\u00e9rateur dispose de la proc\u00e9dure approuv\u00e9e d'arr\u00eat, de r\u00e9initialisation et de mise hors tension.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b9885b71 auto-p elementor-widget elementor-widget-heading\" data-id=\"b9885b71\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">L'\u00e9quipe v\u00e9rifie d'abord les syst\u00e8mes auxiliaires et les communications, l'\u00e9tage de puissance \u00e9tant d\u00e9sactiv\u00e9. Un cycle de charge et de d\u00e9charge \u00e0 faible puissance permet ensuite de confirmer le sens de fonctionnement au niveau de l'armoire et du PCC. Une fois que le compteur et le r\u00e9gulateur sont en accord, le test passe par un point de consigne interm\u00e9diaire et atteint la charge de service du site de 80 kW pendant la dur\u00e9e indiqu\u00e9e dans la proc\u00e9dure.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d1b80a2d auto-p elementor-widget elementor-widget-heading\" data-id=\"d1b80a2d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Trois sc\u00e9narios restent possibles :<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-017d2125 auto-table elementor-widget elementor-widget-text-editor\" data-id=\"017d2125\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"cea-table-wrap\"><table><thead><tr><th>R\u00e9sultat observ\u00e9 sur place<\/th><th>D\u00e9cision du SAT<\/th><\/tr><\/thead><tbody><tr><td>Le gouvernement suit la tendance des 80 kW et celle du PCC \u00e9volue dans le sens pr\u00e9vu<\/td><td>Le mode fonctionnel de lissage des pics peut \u00eatre activ\u00e9, sous r\u00e9serve que tous les contr\u00f4les de protection et de repli soient respect\u00e9s<\/td><\/tr><tr><td>Le bo\u00eetier atteint 80 kW, mais la courbe du PCC indique le contraire<\/td><td>Laissez le mode ouvert ; v\u00e9rifiez l'emplacement des compteurs, les transformateurs de courant, la mise \u00e0 l'\u00e9chelle, le signe et les horodatages<\/td><\/tr><tr><td>La puissance disponible de l'armoire est limit\u00e9e \u00e0 moins de 80 kW en fonction de la temp\u00e9rature, du niveau de charge (SOC), de la puissance r\u00e9active ou d'une autre limite active.<\/td><td>Enregistrez la limite active ; ne transformez pas un passage \u00e0 faible puissance en un passage \u00e0 80 kW<\/td><\/tr><\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f796359d auto-image elementor-widget elementor-widget-image\" data-id=\"f796359d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"800\" height=\"600\" src=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/BESS-SAT-Pass-or-Hold.png\" class=\"attachment-1536x1536 size-1536x1536 wp-image-5184\" alt=\"Comparaison des \u00e9tats \u00ab SAT \u00bb (r\u00e9ussi) ou \u00ab en attente \u00bb (hold) de BESS pour les tendances PCC, les param\u00e8tres de protection, les commandes, l&#039;\u00e9tat et les versions logicielles\" srcset=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/BESS-SAT-Pass-or-Hold.png 800w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/BESS-SAT-Pass-or-Hold-300x225.png 300w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/BESS-SAT-Pass-or-Hold-768x576.png 768w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/BESS-SAT-Pass-or-Hold-16x12.png 16w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/BESS-SAT-Pass-or-Hold-600x450.png 600w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-eceaf393 auto-p elementor-widget elementor-widget-heading\" data-id=\"eceaf393\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Le d\u00e9marrage du compresseur, la demande de puissance r\u00e9active et les chutes de tension sur site doivent faire l'objet de contr\u00f4les sp\u00e9cifiques et homologu\u00e9s lorsqu'ils font partie des conditions d'exploitation. Un fonctionnement stable \u00e0 80 kW ne peut pas prouver qu'un d\u00e9marrage du moteur, qui n'a jamais eu lieu, s'est produit.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3dd0eb94 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"3dd0eb94\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Ne pas inclure la validation des performances dans la mauvaise liste de contr\u00f4le<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-636db555 auto-p elementor-widget elementor-widget-heading\" data-id=\"636db555\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Le SAT doit v\u00e9rifier que les interfaces install\u00e9es sont bien celles requises pour effectuer un test de performance. Il ne doit pas modifier en silence les donn\u00e9es nominales du produit en les consid\u00e9rant comme un r\u00e9sultat valid\u00e9 par le site.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4e6f16d6 auto-p elementor-widget elementor-widget-heading\" data-id=\"4e6f16d6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Cette distinction rev\u00eat une importance particuli\u00e8re dans le domaine de l'\u00e9nergie :<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1591036c auto-p elementor-widget elementor-widget-heading\" data-id=\"1591036c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\"><strong>\u00c9nergie nominale de la batterie \u2260 \u00e9nergie CC utilisable \u2260 \u00e9nergie CA utilisable au niveau du PCS \u2260 \u00e9nergie CA utilisable au niveau du PCC<\/strong><\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-12a07bca auto-p elementor-widget elementor-widget-heading\" data-id=\"12a07bca\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Pour qu'un r\u00e9sultat d'\u00e9nergie utilisable soit valid\u00e9, il doit comporter un point de mesure identifi\u00e9, les niveaux de charge initiale et finale (SOC), la consigne de puissance, la base de temp\u00e9rature, le traitement auxiliaire, l'intervalle d'\u00e9chantillonnage et la m\u00e9thode de calcul. Ces param\u00e8tres de contr\u00f4le doivent figurer dans le <strong><a href=\"https:\/\/www.solidess.com\/fr\/test-de-capacite-du-bess-commercial-pour-verifier-les-kwh-utilisables\/\" target=\"_blank\" style=\"color:#61ce70\">test de capacit\u00e9 des syst\u00e8mes de stockage d'\u00e9nergie par batterie (BESS) \u00e0 usage commercial<\/a><\/strong>.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-de4cb816 auto-p elementor-widget elementor-widget-heading\" data-id=\"de4cb816\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">La m\u00eame distinction s'applique aux autres r\u00e9sultats :<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9f9d4c68 elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"9f9d4c68\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">un contr\u00f4le du fonctionnement du circuit de charge\/d\u00e9charge ne permet pas de v\u00e9rifier la dur\u00e9e de la puissance contractuelle ;<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">le fait qu'une liste d'alarmes soit \u00ab propre \u00bb ne prouve pas les performances harmoniques ;<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">un essai d'une heure en pr\u00e9sence de t\u00e9moins ne prouve pas la disponibilit\u00e9 \u00e0 long terme ;<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">une tendance PCS ne remplace pas la mesure effectu\u00e9e \u00e0 la limite PCC convenue ;<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Une validation fonctionnelle du SAT ne cl\u00f4t pas un test de protection diff\u00e9r\u00e9e ni un test de conformit\u00e9 au code de r\u00e9seau.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d219b58c auto-p elementor-widget elementor-widget-heading\" data-id=\"d219b58c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Le <strong><a href=\"https:\/\/www.solidess.com\/fr\/tests-de-qualite-de-lenergie-pour-la-reception-commerciale-des-systemes-de-stockage-denergie-par-batterie\/\" target=\"_blank\" style=\"color:#61ce70\">Proc\u00e9dure de r\u00e9ception relative \u00e0 la qualit\u00e9 de l'\u00e9nergie du syst\u00e8me BESS<\/a><\/strong> aborde le placement des analyseurs et les conditions d'exploitation pour les r\u00e9sultats relatifs aux harmoniques et \u00e0 la qualit\u00e9 de l'\u00e9nergie \u00e9lectrique. Les alarmes li\u00e9es \u00e0 la fiabilit\u00e9, les restrictions de production et les enregistrements de disponibilit\u00e9 constituent le troisi\u00e8me th\u00e8me de ce groupe. Le fait de s\u00e9parer ces tests permet de raccourcir la dur\u00e9e du SAT et de rendre les signatures plus significatives.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7ba43945 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"7ba43945\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Cl\u00f4turer les \u00e9l\u00e9ments de poin\u00e7onnage sans perdre l'historique des tests<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-922763f2 auto-p elementor-widget elementor-widget-heading\" data-id=\"922763f2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Une liste de corrections devient risqu\u00e9e lorsque la correction modifie la configuration qui a \u00e9t\u00e9 valid\u00e9e. Le remplacement d'une \u00e9tiquette endommag\u00e9e n'a pas d'incidence sur un test fonctionnel. En revanche, le remplacement d'un compteur, la modification d'un param\u00e8tre de protection ou l'installation d'un nouveau logiciel EMS en ont une.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-63742478 auto-p elementor-widget elementor-widget-heading\" data-id=\"63742478\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Utilisez trois dispositions :<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ce8b431d elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"ce8b431d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>Cl\u00f4turer sans nouveau test :<\/strong> correction purement esth\u00e9tique ou documentaire n'ayant aucune incidence sur une fonction test\u00e9e ;<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>Terminer par un nouveau test cibl\u00e9 :<\/strong> un changement d\u00e9fini affectant un signal, un r\u00e9glage, un dispositif ou un mode de fonctionnement ;<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>Repassez la partie du SAT concern\u00e9e :<\/strong> une modification qui affecte plusieurs interfaces ou invalide les preuves initiales.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-bfded074 auto-p elementor-widget elementor-widget-heading\" data-id=\"bfded074\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Chaque cl\u00f4ture doit comporter le num\u00e9ro du d\u00e9faut, la mesure prise, le responsable, la date d'ach\u00e8vement, la r\u00e9f\u00e9rence des preuves et, le cas \u00e9ch\u00e9ant, le r\u00e9sultat du nouveau test. L'ancien r\u00e9sultat reste dans le dossier ; le nouveau test y fait r\u00e9f\u00e9rence. Supprimer une capture d'\u00e9cran indiquant un \u00e9chec et ne conserver que le r\u00e9sultat \u00ab R\u00e9ussi \u00bb ult\u00e9rieur supprime l'historique n\u00e9cessaire pour expliquer la configuration finale.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-567c1f78 auto-p elementor-widget elementor-widget-heading\" data-id=\"567c1f78\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Le micrologiciel m\u00e9rite la m\u00eame rigueur. Si une mise \u00e0 jour EMS modifie la gestion des compteurs, la logique de planification ou le comportement de secours, l\u2019\u00e9quipe sur site r\u00e9p\u00e8te ces fonctions. Les tests sans rapport avec la modification peuvent rester valables lorsque le cahier de configuration d\u00e9finit clairement cette limite.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-36105782 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"36105782\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Le dossier de passation de pouvoir que l\u2019op\u00e9rateur utilisera r\u00e9ellement<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4174f7d8 auto-p elementor-widget elementor-widget-heading\" data-id=\"4174f7d8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">L'op\u00e9rateur n'a pas besoin d'un r\u00e9pertoire rempli de fichiers PDF en double. Le dossier de transfert doit comporter un index succinct indiquant les dossiers pr\u00e9cis correspondant \u00e0 l'usine mise en service.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3dbbb1e9 auto-p elementor-widget elementor-widget-heading\" data-id=\"3dbbb1e9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Conservez ces articles ensemble :<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c8cfbd26 elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"c8cfbd26\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">liste des mod\u00e8les livr\u00e9s et de leurs num\u00e9ros de s\u00e9rie ;<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">les mises \u00e0 jour logicielles approuv\u00e9es des syst\u00e8mes BMS, PCS et EMS ;<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">sch\u00e9ma unifilaire \u00ab tel que construit \u00bb et plans d'interface avec le site ;<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">param\u00e8tres de protection d\u00e9finitifs et historiques des d\u00e9clenchements ;<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">listes des compteurs et des points de communication ;<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">les fiches SAT sign\u00e9es relatives \u00e0 l'installation, \u00e0 la mise sous tension et aux essais fonctionnels ;<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">registre des postes ouverts, avec les restrictions d'exploitation et les dates de cl\u00f4ture ;<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">instructions relatives \u00e0 l'isolement de l'op\u00e9rateur, \u00e0 l'arr\u00eat, \u00e0 la r\u00e9initialisation et \u00e0 la remise en service ;<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">liens vers les r\u00e9sultats relatifs \u00e0 la capacit\u00e9, \u00e0 la qualit\u00e9 de l'alimentation ou \u00e0 la fiabilit\u00e9, \u00e9tablis s\u00e9par\u00e9ment avant la remise des cl\u00e9s.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9efbdfda auto-p elementor-widget elementor-widget-heading\" data-id=\"9efbdfda\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Cet index final devrait permettre \u00e0 un technicien de r\u00e9pondre \u00e0 trois questions sans avoir \u00e0 consulter ses e-mails : quelle machine est install\u00e9e, quel logiciel est en cours d'ex\u00e9cution et quelle version de test sign\u00e9e a valid\u00e9 le mode de fonctionnement actuellement utilis\u00e9.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d0071b18 auto-p elementor-widget elementor-widget-heading\" data-id=\"d0071b18\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Avant la fermeture du dossier, MegSolid peut v\u00e9rifier que l\u2019identifiant de l\u2019armoire fourni, la version logicielle approuv\u00e9e et le r\u00e9sultat SAT sign\u00e9 correspondent bien \u00e0 la m\u00eame configuration valid\u00e9e.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2ed1f041 elementor-tablet-align-center elementor-align-center auto-cta elementor-widget elementor-widget-button\" data-id=\"2ed1f041\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"#elementor-action%3Aaction%3Dpopup%3Aopen%26settings%3DeyJpZCI6Ijk0OCIsInRvZ2dsZSI6ZmFsc2V9\" target=\"_blank\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Contacter MegSolid au sujet de la passation de SAT et BESS<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-481af2fc auto-faq e-flex e-con-boxed e-con e-child\" data-id=\"481af2fc\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ff4e9155 elementor-widget elementor-widget-heading\" data-id=\"ff4e9155\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">FAQ<\/h2>\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-f76c28ae e-con-full e-flex e-con e-child\" data-id=\"f76c28ae\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-de9f6de9 elementor-widget elementor-widget-n-accordion\" data-id=\"de9f6de9\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;default_state&quot;:&quot;all_collapsed&quot;,&quot;max_items_expended&quot;:&quot;one&quot;,&quot;n_accordion_animation_duration&quot;:{&quot;unit&quot;:&quot;ms&quot;,&quot;size&quot;:400,&quot;sizes&quot;:[]}}\" data-widget_type=\"nested-accordion.default\">\n\t\t\t\t\t\t\t<div class=\"e-n-accordion\" aria-label=\"Accord\u00e9on. Ouvrez les liens \u00e0 l&#039;aide de la touche Entr\u00e9e ou de la barre d&#039;espace, fermez-les avec la touche \u00c9chap et naviguez \u00e0 l&#039;aide des touches fl\u00e9ch\u00e9es.\">\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-3730\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"1\" tabindex=\"0\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-3730\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> 1. Que doit contenir une liste de contr\u00f4le pour les essais de r\u00e9ception d'un site BESS ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3730\" class=\"elementor-element elementor-element-62685b07 e-con-full e-flex e-con e-child\" data-id=\"62685b07\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3730\" class=\"elementor-element elementor-element-e1ddb683 e-con-full e-flex e-con e-child\" data-id=\"e1ddb683\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-670ae8c9 elementor-widget elementor-widget-heading\" data-id=\"670ae8c9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Il doit porter sur l'identification des \u00e9quipements, l'installation telle que r\u00e9alis\u00e9e, les v\u00e9rifications des c\u00e2bles et de la mise \u00e0 la terre, la protection, les arr\u00eats d'urgence, les syst\u00e8mes auxiliaires, les communications, le sens de rotation des compteurs, la responsabilit\u00e9 des commandes, la r\u00e9ponse en fonction du mode de fonctionnement, le comportement des alarmes, les points \u00e0 rectifier et les proc\u00e8s-verbaux de r\u00e9ception sign\u00e9s.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-3731\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"2\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-3731\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> 2. Quelle est la diff\u00e9rence entre les taux de graisse corporelle (BESS FAT) et de graisse sous-cutan\u00e9e (SAT) ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3731\" class=\"elementor-element elementor-element-c38bf955 e-con-full e-flex e-con e-child\" data-id=\"c38bf955\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3731\" class=\"elementor-element elementor-element-20cd48e5 e-con-full e-flex e-con e-child\" data-id=\"20cd48e5\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-cfec63a2 elementor-widget elementor-widget-heading\" data-id=\"cfec63a2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Le contr\u00f4le FAT permet de v\u00e9rifier en usine une configuration d\u00e9finie avant l'exp\u00e9dition. Le contr\u00f4le SAT permet de v\u00e9rifier les \u00e9quipements install\u00e9s et leurs interfaces r\u00e9elles sur site. L'orientation finale des transformateurs de courant, le c\u00e2blage du tableau \u00e9lectrique, les circuits de protection et les communications sur site ne peuvent pas \u00eatre valid\u00e9s par la seule simulation en usine.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-3732\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"3\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-3732\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> 3. Un \u00ab SAT PASS \u00bb permet-il de prouver la consommation effective d'\u00e9lectricit\u00e9 en kWh ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3732\" class=\"elementor-element elementor-element-73dc0caa e-con-full e-flex e-con e-child\" data-id=\"73dc0caa\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3732\" class=\"elementor-element elementor-element-5410afb7 e-con-full e-flex e-con e-child\" data-id=\"5410afb7\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-f1ef2e6f elementor-widget elementor-widget-heading\" data-id=\"f1ef2e6f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Uniquement lorsque la proc\u00e9dure SAT sign\u00e9e pr\u00e9voit explicitement un test d'\u00e9nergie utilisable contr\u00f4l\u00e9 \u00e0 la limite CA convenue. Un passage SAT fonctionnel normal ne transforme pas les kWh nominaux de la batterie en \u00e9nergie livr\u00e9e sur site accept\u00e9e.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-3733\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"4\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-3733\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> 4. Un syst\u00e8me de stockage d'\u00e9nergie par batterie (BESS) peut-il \u00eatre mis sous tension avant que tous les \u00e9l\u00e9ments du SAT ne soient termin\u00e9s ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3733\" class=\"elementor-element elementor-element-85bebca4 e-con-full e-flex e-con e-child\" data-id=\"85bebca4\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3733\" class=\"elementor-element elementor-element-f636165e e-con-full e-flex e-con e-child\" data-id=\"f636165e\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-34c63081 elementor-widget elementor-widget-heading\" data-id=\"34c63081\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Oui, lorsque la proc\u00e9dure approuv\u00e9e distingue la mise sous tension en toute s\u00e9curit\u00e9 des validations fonctionnelles et de performance ult\u00e9rieures. Les d\u00e9fauts bloquants li\u00e9s \u00e0 la s\u00e9curit\u00e9, \u00e0 la protection ou \u00e0 l'installation doivent \u00eatre corrig\u00e9s avant la mise sous tension. Les modes de fonctionnement restent d\u00e9sactiv\u00e9s jusqu'\u00e0 ce que les v\u00e9rifications requises aient \u00e9t\u00e9 effectu\u00e9es avec succ\u00e8s.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-3734\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"5\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-3734\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> 5. Quels d\u00e9fauts du syst\u00e8me de stockage d'\u00e9nergie par batterie (BESS) devraient emp\u00eacher la mise sous tension ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3734\" class=\"elementor-element elementor-element-dad8ff96 e-con-full e-flex e-con e-child\" data-id=\"dad8ff96\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3734\" class=\"elementor-element elementor-element-323587bd e-con-full e-flex e-con e-child\" data-id=\"323587bd\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c515d9ac elementor-widget elementor-widget-heading\" data-id=\"c515d9ac\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">On peut citer, \u00e0 titre d'exemple, des r\u00e9glages de protection non approuv\u00e9s, des anomalies non r\u00e9solues au niveau du c\u00e2blage ou de la mise \u00e0 la terre, une identification incorrecte des \u00e9quipements, des r\u00e9sultats d'essais d'isolation non conformes, des circuits de d\u00e9clenchement d'urgence incomplets et des modifications apport\u00e9es apr\u00e8s la mise en service qui affectent les caract\u00e9ristiques nominales ou la s\u00e9curit\u00e9.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-3735\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"6\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-3735\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> 6. Pourquoi faut-il effectuer d'abord des cycles de charge et de d\u00e9charge \u00e0 faible puissance avant de passer \u00e0 pleine puissance ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3735\" class=\"elementor-element elementor-element-e92829f5 e-con-full e-flex e-con e-child\" data-id=\"e92829f5\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3735\" class=\"elementor-element elementor-element-7a854d11 e-con-full e-flex e-con e-child\" data-id=\"7a854d11\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-704de3e0 elementor-widget elementor-widget-heading\" data-id=\"704de3e0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Un fonctionnement \u00e0 faible puissance permet de v\u00e9rifier le sens de rotation, la cartographie de phase, la r\u00e9troaction et l'attribution des commandes, tout en r\u00e9duisant les contraintes de fonctionnement. Le passage \u00e0 pleine puissance intervient une fois que la cha\u00eene de mesure et de protection a r\u00e9agi correctement. La valeur de consigne r\u00e9elle pour le fonctionnement \u00e0 faible puissance doit figurer dans la proc\u00e9dure du site.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-3736\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"7\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-3736\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> 7. Que doit-il se passer si l'importation de PCC augmente pendant une commande de d\u00e9charge ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3736\" class=\"elementor-element elementor-element-239f4351 e-con-full e-flex e-con e-child\" data-id=\"239f4351\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3736\" class=\"elementor-element elementor-element-349b367a e-con-full e-flex e-con e-child\" data-id=\"349b367a\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-87c01bc5 elementor-widget elementor-widget-heading\" data-id=\"87c01bc5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Interrompez le fonctionnement et v\u00e9rifiez l'emplacement du compteur, la polarit\u00e9 du transformateur de courant, son rapport de transformation, l'affectation des phases, la convention des signes et l'alignement des horodatages. Augmenter la commande avant d'avoir r\u00e9solu l'erreur de mesure peut pousser le r\u00e9gulateur encore plus loin dans la mauvaise direction.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-3737\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"8\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-3737\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> 8. Qui doit signer le formulaire BESS SAT ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3737\" class=\"elementor-element elementor-element-f1253a53 e-con-full e-flex e-con e-child\" data-id=\"f1253a53\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3737\" class=\"elementor-element elementor-element-66fd9fe7 e-con-full e-flex e-con e-child\" data-id=\"66fd9fe7\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c693ca0b elementor-widget elementor-widget-heading\" data-id=\"c693ca0b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Le contrat doit pr\u00e9ciser les r\u00f4les respectifs du fournisseur agr\u00e9\u00e9, du ma\u00eetre d\u2019\u0153uvre (EPC), du responsable de la mise en service, du ma\u00eetre d\u2019ouvrage et du t\u00e9moin ind\u00e9pendant. Chaque signature doit indiquer la section d\u2019essai et la d\u00e9cision de r\u00e9ception qu\u2019elle couvre ; une signature g\u00e9n\u00e9rale ne doit pas valider tacitement des essais de performance report\u00e9s.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-3738\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"9\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-3738\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> 9. Une mise \u00e0 jour du micrologiciel devrait-elle d\u00e9clencher un nouveau SAT ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3738\" class=\"elementor-element elementor-element-3f24ae04 e-con-full e-flex e-con e-child\" data-id=\"3f24ae04\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3738\" class=\"elementor-element elementor-element-56d0485d e-con-full e-flex e-con e-child\" data-id=\"56d0485d\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-3cf3be1c elementor-widget elementor-widget-heading\" data-id=\"3cf3be1c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">R\u00e9p\u00e9tez chaque fonction concern\u00e9e par la modification et associez le nouveau r\u00e9sultat au test initial. Toute modification apport\u00e9e au fonctionnement du compteur, \u00e0 la priorit\u00e9 des commandes ou \u00e0 la logique de secours n\u00e9cessite de nouveaux tests cibl\u00e9s sur site, m\u00eame si le mat\u00e9riel reste inchang\u00e9.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-3739\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"10\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-3739\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> 10. Le lissage des pics peut-il se poursuivre alors que le mode de secours reste actif ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3739\" class=\"elementor-element elementor-element-9c3c4c8b e-con-full e-flex e-con e-child\" data-id=\"9c3c4c8b\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3739\" class=\"elementor-element elementor-element-3a45de93 e-con-full e-flex e-con e-child\" data-id=\"3a45de93\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-31d90bf7 elementor-widget elementor-widget-heading\" data-id=\"31d90bf7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Oui. Les modes de fonctionnement peuvent utiliser diff\u00e9rents compteurs, r\u00e8gles SOC, \u00e9tats des disjoncteurs et r\u00e9ponses en cas de d\u00e9faillance. Le rapport SAT ne doit valider que les modes qui ont \u00e9t\u00e9 test\u00e9s avec succ\u00e8s dans les conditions approuv\u00e9es.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-37310\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"11\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-37310\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> 11. Quelle est la diff\u00e9rence entre le SAT et la mise en service ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-37310\" class=\"elementor-element elementor-element-16f4ccd0 e-con-full e-flex e-con e-child\" data-id=\"16f4ccd0\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-37310\" class=\"elementor-element elementor-element-f016354f e-con-full e-flex e-con e-child\" data-id=\"f016354f\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a37e6c78 elementor-widget elementor-widget-heading\" data-id=\"a37e6c78\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">La mise en service d\u00e9signe l'ensemble du processus comprenant les contr\u00f4les de fin de travaux, la mise sous tension, le d\u00e9marrage, les essais fonctionnels, les v\u00e9rifications de performances, la formation et la remise des installations. La SAT (acceptation sur site) correspond \u00e0 la phase officielle d'acceptation sur site qui permet de valider les fonctions install\u00e9es d\u00e9finies.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-37311\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"12\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-37311\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> 12. Que doit contenir un dossier de passation de pouvoirs BESS ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-37311\" class=\"elementor-element elementor-element-e5c69f1a e-con-full e-flex e-con e-child\" data-id=\"e5c69f1a\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-37311\" class=\"elementor-element elementor-element-e8a3b684 e-con-full e-flex e-con e-child\" data-id=\"e8a3b684\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ff8c778b elementor-widget elementor-widget-heading\" data-id=\"ff8c778b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Veuillez inclure les num\u00e9ros de mod\u00e8le et de s\u00e9rie des \u00e9quipements livr\u00e9s, la liste des logiciels valid\u00e9s, les plans de fin de travaux, les param\u00e8tres de protection, les listes de compteurs et de points de mesure, les fiches SAT sign\u00e9es, l'\u00e9tat d'avancement de la liste des travaux restants, les proc\u00e9dures d'exploitation ainsi que les r\u00e9f\u00e9rences aux r\u00e9sultats de performance pr\u00e9sent\u00e9s s\u00e9par\u00e9ment.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-37312\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"13\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-37312\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> 13. Comment l'ESSA0100B-0215 s'adapte-t-il \u00e0 un SAT de 400 V ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-37312\" class=\"elementor-element elementor-element-7360afbe e-con-full e-flex e-con e-child\" data-id=\"7360afbe\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-37312\" class=\"elementor-element elementor-element-5fa67b7d e-con-full e-flex e-con e-child\" data-id=\"5fa67b7d\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-03370ea0 elementor-widget elementor-widget-heading\" data-id=\"03370ea0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Sa puissance nominale en courant alternatif de 100 kW, son \u00e9nergie nominale de 215,04 kWh et son interface de 400 V constituent les caract\u00e9ristiques de base du produit. SAT proc\u00e8de toujours \u00e0 la v\u00e9rification finale de la ligne d'alimentation, du tableau \u00e9lectrique, des dispositifs de protection, du compteur, des syst\u00e8mes de communication et des modes de fonctionnement approuv\u00e9s sur le site du projet.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Une liste de contr\u00f4le pratique pour le syst\u00e8me BESS SAT C&amp;I, permettant de v\u00e9rifier l'installation, la protection, les interfaces de commande et les proc\u00e8s-verbaux de remise sign\u00e9s avant la mise en service.<\/p>","protected":false},"author":4,"featured_media":5182,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"_joinchat":[],"footnotes":""},"categories":[27,1],"tags":[541,224,542,540,237,316,184,36],"class_list":["post-5185","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-news","category-bess","tag-400-v-bess","tag-bess-commissioning","tag-bess-handover","tag-bess-sat-checklist","tag-bess-site-acceptance-test","tag-ci-bess","tag-essa0100b-0215","tag-MegSolid"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/posts\/5185","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/comments?post=5185"}],"version-history":[{"count":4,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/posts\/5185\/revisions"}],"predecessor-version":[{"id":5197,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/posts\/5185\/revisions\/5197"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/media\/5182"}],"wp:attachment":[{"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/media?parent=5185"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/categories?post=5185"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/tags?post=5185"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}