{"id":5193,"date":"2026-09-04T10:50:00","date_gmt":"2026-09-04T02:50:00","guid":{"rendered":"https:\/\/www.solidess.com\/?p=5193"},"modified":"2026-09-04T10:49:50","modified_gmt":"2026-09-04T02:49:50","slug":"bess-ct-mesure-de-la-polarite-mise-en-service","status":"publish","type":"post","link":"https:\/\/www.solidess.com\/fr\/bess-ct-polarity-metering-commissioning\/","title":{"rendered":"Comment v\u00e9rifier le comptage du BESS et la polarit\u00e9 du transformateur de courant lors de la mise en service"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"5193\" class=\"elementor elementor-5193\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-bf4793c e-con-full auto-article-root e-flex e-con e-parent\" data-id=\"bf4793c\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-6ad7038d auto-p elementor-widget elementor-widget-heading\" data-id=\"6ad7038d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Une validation de polarit\u00e9 du transformateur de courant (TC) du syst\u00e8me BESS d\u00e9clenche l'\u00e9mission du signal PCC correspondant pour les modes de fonctionnement couverts par le test. Les kWh utilisables, la qualit\u00e9 de l'\u00e9nergie et la disponibilit\u00e9 restent soumis \u00e0 leurs propres proc\u00e9dures. Avant que le r\u00e9sultat de comptage puisse \u00eatre valid\u00e9, les \u00e9quipes charg\u00e9es de l'\u00e9lectricit\u00e9 et des commandes doivent s'accorder sur le point de mesure, le rapport du TC, la polarit\u00e9, l'appariement des phases, le signe logiciel et l'horodatage.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f04a86f4 auto-p elementor-widget elementor-widget-heading\" data-id=\"f04a86f4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Lorsqu'une tension de 400 V <strong><a href=\"https:\/\/www.solidess.com\/fr\/product\/systeme-de-stockage-denergie-en-armoire-exterieure\/\" target=\"_blank\" style=\"color:#61ce70\">MegSolid ESSA0100B-0215<\/a><\/strong> Si une commande de charge ou de d\u00e9charge est \u00e9mise, une cha\u00eene de mesure PCC install\u00e9e sur site et \u00e9quip\u00e9e de transformateurs de courant invers\u00e9s peut tout de m\u00eame indiquer le sens inverse. La r\u00e9ponse de l'armoire et la mesure sur site ont des limites de test distinctes. La <strong><a href=\"https:\/\/www.solidess.com\/fr\/ci-bess-testing-fat-sat-performance-acceptance\/\" target=\"_blank\" style=\"color:#61ce70\">S\u00e9quence de test du syst\u00e8me BESS C&amp;I<\/a><\/strong> effectue sur site les derniers contr\u00f4les du transformateur de courant, de l'entr\u00e9e de tension, des compteurs et du r\u00e9seau.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-da14e898 auto-p elementor-widget elementor-widget-heading\" data-id=\"da14e898\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Le lissage des pics et l'exportation nulle agissent tous deux sur le signal PCC. Le <strong><a href=\"https:\/\/www.solidess.com\/fr\/comment-specifier-un-controle-de-zero-injection-au-pcc-pour-un-systeme-de-stockage-denergie-par-batterie-bess\/\" target=\"_blank\" style=\"color:#61ce70\">Sp\u00e9cification de contr\u00f4le \u00ab z\u00e9ro exportation \u00bb BESS<\/a><\/strong> d\u00e9finit les limites de r\u00e9gulation. La mise en service doit permettre de v\u00e9rifier que le signal install\u00e9 \u00e9volue dans le m\u00eame sens que le flux de puissance physique.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-44751b89 auto-image elementor-widget elementor-widget-image\" data-id=\"44751b89\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"850\" height=\"850\" src=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/BESS-CT-Polarity-Commissioning.png\" class=\"attachment-1536x1536 size-1536x1536 wp-image-5190\" alt=\"MegSolid ESSA0100B-0215 \u00e0 c\u00f4t\u00e9 d&#039;un tableau \u00e9lectrique de 400 V lors de la mise en service de la polarit\u00e9 du BESS CT\" srcset=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/BESS-CT-Polarity-Commissioning.png 850w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/BESS-CT-Polarity-Commissioning-300x300.png 300w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/BESS-CT-Polarity-Commissioning-150x150.png 150w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/BESS-CT-Polarity-Commissioning-768x768.png 768w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/BESS-CT-Polarity-Commissioning-12x12.png 12w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/BESS-CT-Polarity-Commissioning-600x600.png 600w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/BESS-CT-Polarity-Commissioning-100x100.png 100w\" sizes=\"(max-width: 850px) 100vw, 850px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e1aafc21 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"e1aafc21\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Pourquoi la polarit\u00e9 CT ne suffit pas \u00e0 elle seule \u00e0 prouver le sens de la puissance dans le PCC<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5a01fa15 auto-p elementor-widget elementor-widget-heading\" data-id=\"5a01fa15\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Un transformateur de courant (TC) classique convertit un courant primaire en un courant secondaire de plus faible intensit\u00e9. Les notions d'importation, d'exportation, de charge et de d\u00e9charge prennent tout leur sens plus loin dans le circuit de mesure. L'orientation du TC, les bornes secondaires, l'appariement tension-phase, les r\u00e9glages du compteur, les registres de communication et le signe EMS ont tous une incidence sur la valeur finale.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3e179e19 auto-p elementor-widget elementor-widget-heading\" data-id=\"3e179e19\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Un test de polarit\u00e9 peut donner un r\u00e9sultat satisfaisant alors m\u00eame que la valeur du PCC sous tension reste erron\u00e9e. Les valeurs P1\/P2 et S1\/S2 peuvent correspondre, mais le courant L1 peut \u00eatre associ\u00e9 \u00e0 la tension L2. Le compteur peut calculer le courant primaire correct, mais le syst\u00e8me EMS peut le recalculer. M\u00eame une valeur correcte devient trompeuse lorsque son horodatage est compar\u00e9 \u00e0 une commande PCS erron\u00e9e.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d66b7e53 auto-p elementor-widget elementor-widget-heading\" data-id=\"d66b7e53\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">La mise en service s'effectue \u00e0 la suite du signal transmis par le conducteur principal vers le dispositif de commande. Le r\u00e9sultat, avec signe, indique le compteur, les r\u00e9glages et le mode de fonctionnement utilis\u00e9s lors de ce cycle.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a9068cb0 auto-h3 elementor-widget elementor-widget-heading\" data-id=\"a9068cb0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Une lecture plausible peut tout de m\u00eame entra\u00eener un fonctionnement incorrect de la batterie<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9eb2affe auto-p elementor-widget elementor-widget-heading\" data-id=\"9eb2affe\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Prenons l'exemple d'une usine dont l'entr\u00e9e principale absorbe environ 420 kW. L'ing\u00e9nieur charg\u00e9 de la mise en service ordonne une d\u00e9charge de 20 kW. Le PCS atteint sa valeur de consigne, mais le compteur du PCC continue d'afficher une valeur qui s'approche de 440 kW. Observ\u00e9es sur des \u00e9crans distincts, aucune de ces deux valeurs ne semble aberrante.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d8f2baf3 auto-p elementor-widget elementor-widget-heading\" data-id=\"d8f2baf3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">C'est l'ing\u00e9nieur qui a le contr\u00f4le \u00e0 ce stade. L'inversion des transformateurs de courant (TC) est l'une des explications possibles ; un d\u00e9calage de phase entre la tension et le courant, un multiplicateur de TC doubl\u00e9 ou un signe EMS invers\u00e9 peuvent produire une tendance similaire. Un d\u00e9calage d'horloge peut \u00e9galement attribuer une augmentation de charge \u00e0 une commande de batterie erron\u00e9e.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b2462863 auto-p elementor-widget elementor-widget-heading\" data-id=\"b2462863\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Les valeurs initiales par phase sont enregistr\u00e9es avant toute modification du c\u00e2blage ou du logiciel. Le d\u00e9pannage s'effectue ensuite en remontant des conducteurs vers l'\u00e9tiquette EMS, couche par couche.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-cdc59d67 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"cdc59d67\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Commencez par d\u00e9finir les limites et les conventions de signalisation<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3e24349b auto-p elementor-widget elementor-widget-heading\" data-id=\"3e24349b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Un compteur correctement c\u00e2bl\u00e9, mais install\u00e9 au mauvais endroit, ne permet pas de g\u00e9rer l'\u00e9cr\u00eatement des pics \u00e0 l'\u00e9chelle de l'ensemble du site. Pour l'\u00e9cr\u00eatement des pics en usine, la mesure du PCC est g\u00e9n\u00e9ralement situ\u00e9e en amont des charges du site et du circuit d'alimentation du BESS, de sorte qu'elle refl\u00e8te l'\u00e9change total avec le r\u00e9seau. Un compteur install\u00e9 sur le circuit d'alimentation du BESS ne mesure que la puissance de l'armoire. Un compteur install\u00e9 sur un tableau de production ne prend pas en compte les charges situ\u00e9es en dehors de ce tableau.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-afdd37ee auto-p elementor-widget elementor-widget-heading\" data-id=\"afdd37ee\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Reproduisez le sch\u00e9ma unifilaire approuv\u00e9 et indiquez :<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3ae7f165 elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"3ae7f165\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">le conducteur principal traversant chaque transformateur de courant ;<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">la prise de tension utilis\u00e9e par le compteur ;<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">le compteur ou la passerelle transmettant la puissance active ;<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">la balise EMS qui re\u00e7oit cette valeur ;<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">chaque multiplication ou changement de signe entre le compteur et le r\u00e9gulateur.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a919c046 auto-p elementor-widget elementor-widget-heading\" data-id=\"a919c046\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Le <strong><a href=\"https:\/\/www.solidess.com\/fr\/connexion-de-batterie-400-v-au-tableau-electrique-existant\/\" target=\"_blank\" style=\"color:#61ce70\">Guide du tableau \u00e9lectrique BESS 400 V<\/a><\/strong> s\u00e9pare l'alimentation de l'armoire de l'alimentation d'entr\u00e9e, du jeu de barres et de la protection du site. Le sch\u00e9ma utilis\u00e9 pour la mise en service doit indiquer cette distinction physique.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-54243aa5 auto-p elementor-widget elementor-widget-heading\" data-id=\"54243aa5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Indiquez la convention de signe \u00e0 c\u00f4t\u00e9 du sch\u00e9ma. En cas d\u2019importation de l\u2019\u00e9nergie via le r\u00e9seau et de charge du BESS, les valeurs sont positives :<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1a4a7a9e auto-p elementor-widget elementor-widget-heading\" data-id=\"1a4a7a9e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\"><strong>P<sub>PCC<\/sub> \u2248 P<sub>temps de chargement du site<\/sub> + P<sub>BESS<\/sub><\/strong><\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-33b24ac7 auto-p elementor-widget elementor-widget-heading\" data-id=\"33b24ac7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">La d\u00e9charge produit P<sub>BESS<\/sub> n\u00e9gatif, de sorte que l'importation PCC diminue lorsque la charge de l'installation reste globalement stable. La recharge entra\u00eene une augmentation de l'importation. Les projets peuvent adopter une convention de signe diff\u00e9rente. Le compteur, l'EMS, le PCS, le SCADA et le test de signe doivent n\u00e9anmoins s'accorder sur une d\u00e9finition unique.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1a24d3ea auto-image elementor-widget elementor-widget-image\" data-id=\"1a24d3ea\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"1000\" height=\"750\" src=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/PCC-Metering-Signal-Path.png\" class=\"attachment-1536x1536 size-1536x1536 wp-image-5191\" alt=\"Cheminement du signal de mesure du PCC, depuis les transformateurs de courant du r\u00e9seau jusqu&#039;\u00e0 l&#039;armoire MegSolid ESSA, en passant par le compteur d&#039;\u00e9nergie et l&#039;EMS\" srcset=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/PCC-Metering-Signal-Path.png 1000w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/PCC-Metering-Signal-Path-300x225.png 300w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/PCC-Metering-Signal-Path-768x576.png 768w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/PCC-Metering-Signal-Path-16x12.png 16w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/PCC-Metering-Signal-Path-600x450.png 600w\" sizes=\"(max-width: 1000px) 100vw, 1000px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1809719c auto-h2 elementor-widget elementor-widget-heading\" data-id=\"1809719c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">\u00c9l\u00e9ments \u00e0 v\u00e9rifier au niveau du compteur et du CT<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-202c94f4 auto-p elementor-widget elementor-widget-heading\" data-id=\"202c94f4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">La v\u00e9rification hors tension commence au niveau du transformateur de courant install\u00e9. La plaque signal\u00e9tique indique les valeurs nominales primaires et secondaires, la classe de pr\u00e9cision, la charge nominale et le marquage des bornes ; certains mod\u00e8les portent \u00e9galement un num\u00e9ro de s\u00e9rie unique. L'entr\u00e9e du compteur doit correspondre au circuit secondaire install\u00e9 de 1 A ou 5 A.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-99b1680d auto-h3 elementor-widget elementor-widget-heading\" data-id=\"99b1680d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Ratio et mise \u00e0 l'\u00e9chelle<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-64076b65 auto-p elementor-widget elementor-widget-heading\" data-id=\"64076b65\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Un transformateur de courant 600\/5 A a un rapport de 120:1. Si un appareil de mesure adapt\u00e9 indique 2,5 A du c\u00f4t\u00e9 secondaire, le courant correspondant du c\u00f4t\u00e9 primaire est de 300 A.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9855efa5 auto-p elementor-widget elementor-widget-heading\" data-id=\"9855efa5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\"><strong>Courant primaire = courant secondaire \u00d7 rapport du transformateur de courant<\/strong><\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1e37fb49 auto-p elementor-widget elementor-widget-heading\" data-id=\"1e37fb49\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Un compteur r\u00e9gl\u00e9 sur 600\/1 A sur ce circuit de 600\/5 A g\u00e9n\u00e8re une erreur \u00e0 facteur fixe. Une erreur similaire se produit lorsque le compteur affiche d\u00e9j\u00e0 les amp\u00e8res primaires et que le syst\u00e8me EMS multiplie \u00e0 nouveau la valeur affich\u00e9e.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6f341a60 auto-p elementor-widget elementor-widget-heading\" data-id=\"6f341a60\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Indiquez le rapport de l'\u00e9tiquette \u00e0 c\u00f4t\u00e9 du r\u00e9glage du compteur, de l'unit\u00e9 de protocole et du multiplicateur EMS. Le calcul de la charge tient \u00e9galement compte des c\u00e2bles secondaires, des bornes, des blocs de test et de tout instrument connect\u00e9 en s\u00e9rie. Les longues longueurs de c\u00e2bles secondaires m\u00e9ritent une attention particuli\u00e8re, car une charge excessive entra\u00eene des erreurs de rapport et de phase.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ef8eff51 auto-h3 elementor-widget elementor-widget-heading\" data-id=\"ef8eff51\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Polarit\u00e9 et rep\u00e9rage des bornes<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6ee84507 auto-p elementor-widget elementor-widget-heading\" data-id=\"6ee84507\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Les transformateurs de courant peuvent utiliser les rep\u00e8res P1\/P2, S1\/S2, H1\/H2, X1\/X2, K\/L et k\/l, ou une fl\u00e8che. Respectez le sch\u00e9ma fourni par le fabricant et le plan d'ex\u00e9cution approuv\u00e9. La couleur des c\u00e2bles ne permet pas de d\u00e9terminer la polarit\u00e9.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-14a8a399 auto-p elementor-widget elementor-widget-heading\" data-id=\"14a8a399\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Ne laissez pas le secondaire d'un transformateur de courant (TC) classique sous tension \u00e0 l'air libre. La documentation relative aux compteurs de Schneider Electric exige \u00e9galement la mise \u00e0 la terre du secondaire du TC conform\u00e9ment aux instructions de l'\u00e9quipement et met en garde contre l'utilisation de l'\u00e9cran d'un compteur pour v\u00e9rifier qu'un circuit est hors tension. Le personnel \u00e9lectricien qualifi\u00e9 doit utiliser les dispositifs d'isolation, de court-circuit et de test homologu\u00e9s. Le <a href=\"https:\/\/www.productinfo.schneider-electric.com\/iem3100_iem3200_iem3300\/iem3100_iem3200_iem3300-series_user-manual\/iEM3100_iEM3200_iEM3300%20series_User%20Manual\/English\/DOCA0005EN-15.pdf\" target=\"_blank\" rel=\"noopener\" style=\"color:#61CE70\">manuel de s\u00e9curit\u00e9 du fabricant<\/a> d\u00e9termine la m\u00e9thode de travail.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9c3c7d32 auto-h3 elementor-widget elementor-widget-heading\" data-id=\"9c3c7d32\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Association de phases<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4b92a7b8 auto-p elementor-widget elementor-widget-heading\" data-id=\"4b92a7b8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Chaque circuit de courant doit \u00eatre aliment\u00e9 par la tension de la m\u00eame phase. Le courant provenant de L1, associ\u00e9 \u00e0 la tension de L2, peut donner une valeur de courant plausible, tandis que la puissance active, la puissance r\u00e9active et le facteur de puissance seront erron\u00e9s. Lorsqu'une phase fournit une puissance n\u00e9gative, le total triphas\u00e9 peut tout de m\u00eame sembler plausible.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-41542158 auto-p elementor-widget elementor-widget-heading\" data-id=\"41542158\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">V\u00e9rifiez la tension, le courant, la puissance active, la puissance r\u00e9active, le facteur de puissance et l'angle de phase pour chaque phase. Un affichage des phaseurs permet de d\u00e9tecter les phases invers\u00e9es et les inversions de sens de courant. Schweitzer Engineering Laboratories mentionne l'affichage des phaseurs comme un outil de mise en service permettant de v\u00e9rifier la polarit\u00e9 et la phase des transformateurs de courant (TC) dans son <a href=\"https:\/\/selinc.com\/api\/download\/2818\/\" target=\"_blank\" rel=\"noopener\" style=\"color:#61CE70\">Documentation SEL-787<\/a>. Le compteur de projet ou l'analyseur de qualit\u00e9 de l'\u00e9nergie peut fournir la m\u00eame comparaison s'il prend en charge l'affichage des phaseurs.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-15f1fa6b auto-h2 elementor-widget elementor-widget-heading\" data-id=\"15f1fa6b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Associer l'injection secondaire \u00e0 un test de polarit\u00e9 sous tension<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-cbaec8e4 auto-p elementor-widget elementor-widget-heading\" data-id=\"cbaec8e4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">L'injection secondaire permet de v\u00e9rifier le circuit en aval sans d\u00e9pendre de la charge de l'installation. Les valeurs connues de courant et de tension permettent de valider la mise \u00e0 l'\u00e9chelle des entr\u00e9es du compteur, l'affectation des phases, le signe de la puissance active, le mappage des registres et la valeur re\u00e7ue par le syst\u00e8me de gestion \u00e9nerg\u00e9tique (EMS).<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2f2c7b00 auto-p elementor-widget elementor-widget-heading\" data-id=\"2f2c7b00\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Une injection secondaire ne permet pas de tester le sens du conducteur principal. Le fait de placer les sondes \u00e0 proximit\u00e9 du compteur peut \u00e9galement contourner les bornes de champ et les tron\u00e7ons de c\u00e2ble. Marquez le point d'injection et la partie du circuit couverte par le test.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-09b51910 auto-p elementor-widget elementor-widget-heading\" data-id=\"09b51910\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Un test en direct de bout en bout comble la lacune restante :<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ec947d5d elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"ec947d5d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">1. \u00c9tablir une charge stable de l'installation ou un \u00e9tat de courant primaire contr\u00f4l\u00e9.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">2. Comparer chaque phase \u00e0 un instrument de r\u00e9f\u00e9rence \u00e9talonn\u00e9.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">3. Enregistrer la puissance de r\u00e9f\u00e9rence du PCC et l'\u00e9tat de qualit\u00e9 du compteur.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">4. Envoyer une commande de charge de faible intensit\u00e9 au BESS, puis revenir \u00e0 z\u00e9ro.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">5. \u00c9mettez une commande de d\u00e9charge de faible intensit\u00e9, d'une ampleur similaire.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">6. Comparer la commande, la puissance du PCS et le d\u00e9placement du PCC sur une m\u00eame \u00e9chelle de temps.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">7. Interrompez le signal du compteur s\u00e9lectionn\u00e9 et observez le d\u00e9lai d'expiration, l'alarme, le basculement et la reprise.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-99800245 auto-image elementor-widget elementor-widget-image\" data-id=\"99800245\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"900\" height=\"675\" src=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/BESS-Power-Direction-Test.png\" class=\"attachment-1536x1536 size-1536x1536 wp-image-5192\" alt=\"Ing\u00e9nieur comparant les relev\u00e9s des transformateurs de courant triphas\u00e9s avec les courbes de puissance synchronis\u00e9es du PCC et du BESS pendant la mise en service\" srcset=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/BESS-Power-Direction-Test.png 900w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/BESS-Power-Direction-Test-300x225.png 300w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/BESS-Power-Direction-Test-768x576.png 768w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/BESS-Power-Direction-Test-16x12.png 16w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/BESS-Power-Direction-Test-600x450.png 600w\" sizes=\"(max-width: 900px) 100vw, 900px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5431ce65 auto-p elementor-widget elementor-widget-heading\" data-id=\"5431ce65\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">La premi\u00e8re commande doit simplement tenir compte des variations normales de charge et de la r\u00e9solution du compteur. Sur un site, cela peut correspondre \u00e0 10 kW ; sur un autre, 20 kW se perdent dans les fluctuations de production. La proc\u00e9dure d\u00e9finit une valeur r\u00e9alisable en fonction du profil de charge r\u00e9el, de la puissance disponible de la batterie et des conditions de test.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-354937b0 auto-p elementor-widget elementor-widget-heading\" data-id=\"354937b0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Pour les syst\u00e8mes MegSolid connect\u00e9s \u00e0 des appareillages de commutation et \u00e0 des compteurs tiers, la v\u00e9rification de l'interface permet d'harmoniser le sens des transformateurs de courant, la mise \u00e0 l'\u00e9chelle du protocole et le mode de secours approuv\u00e9 avant la mise en service de la commande automatique.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d0f6dfeb elementor-tablet-align-center elementor-align-center auto-cta elementor-widget elementor-widget-button\" data-id=\"d0f6dfeb\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"#elementor-action%3Aaction%3Dpopup%3Aopen%26settings%3DeyJpZCI6Ijk0OCIsInRvZ2dsZSI6ZmFsc2V9\" target=\"_blank\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Contactez MegSolid au sujet de l'int\u00e9gration des compteurs PCC<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-be3bad58 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"be3bad58\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Harmoniser toutes les tendances des tests sur une m\u00eame base temporelle<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2f47345a auto-p elementor-widget elementor-widget-heading\" data-id=\"2f47345a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Un compteur PCC peut afficher un r\u00e9sultat moyen apr\u00e8s que le PCS a r\u00e9agi. Lorsque les horloges de l'EMS, du compteur et du syst\u00e8me SCADA ne sont pas synchronis\u00e9es, la courbe de tendance export\u00e9e peut associer une commande \u00e0 une r\u00e9ponse erron\u00e9e. Cela peut amener l'\u00e9quipe \u00e0 rev\u00e9rifier un c\u00e2blage qui \u00e9tait pourtant correct depuis le d\u00e9but.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-62fcd807 auto-p elementor-widget elementor-widget-heading\" data-id=\"62fcd807\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Avant de passer \u00e0 la phase en direct, comparez l'heure affich\u00e9e sur le compteur, le PCS, l'EMS et l'historique. Notez la source de l'heure et l'\u00e9tat de synchronisation pour chaque appareil. Les syst\u00e8mes industriels utilisent des horloges NTP, SNTP, PTP, GPS et locales ; la m\u00e9thode \u00e0 utiliser d\u00e9pend des capacit\u00e9s de l'\u00e9quipement et de la r\u00e9solution du test.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e703ce47 auto-p elementor-widget elementor-widget-heading\" data-id=\"e703ce47\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">La tol\u00e9rance temporelle d\u00e9pend de la r\u00e9ponse de contr\u00f4le, de la fr\u00e9quence de mise \u00e0 jour des compteurs et de la r\u00e9solution des donn\u00e9es. La proc\u00e9dure pr\u00e9cise la diff\u00e9rence autoris\u00e9e, l'intervalle d'\u00e9chantillonnage, la fen\u00eatre de moyennage et le fuseau horaire. Un \u00e9v\u00e9nement connu doit appara\u00eetre \u00e0 l'heure pr\u00e9vue dans chaque enregistrement. Si l'analyse applique une correction temporelle, le rapport conserve \u00e0 la fois l'horodatage d'origine et l'ajustement.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-55142f53 auto-p elementor-widget elementor-widget-heading\" data-id=\"55142f53\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Le <strong><a href=\"https:\/\/www.solidess.com\/fr\/liste-des-points-scada-bess-ce-que-votre-ems-doit-envoyer\/\" target=\"_blank\" style=\"color:#61ce70\">Liste des points SCADA BESS<\/a><\/strong> doit utiliser les m\u00eames noms de balises, unit\u00e9s et champs de qualit\u00e9 que la trace de mise en service. Le <strong><a href=\"https:\/\/www.solidess.com\/fr\/architecture-de-communication-bms-ems-dans-un-bess\/\" target=\"_blank\" style=\"color:#61ce70\">Architecture de communication entre le BMS et l'EMS<\/a><\/strong> explique quelles limites restent locales lorsque le signal PCC devient obsol\u00e8te ou dispara\u00eet.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1c06d050 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"1c06d050\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Identifiez le probl\u00e8me avant de modifier le c\u00e2blage<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1631152f auto-p elementor-widget elementor-widget-heading\" data-id=\"1631152f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Enregistrez les valeurs par phase avant de d\u00e9placer des c\u00e2bles ou de modifier le logiciel. Le profil permet g\u00e9n\u00e9ralement d'identifier le d\u00e9faut plus rapidement que la valeur totale en kW.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-77f64adb auto-table elementor-widget elementor-widget-text-editor\" data-id=\"77f64adb\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"cea-table-wrap\"><table><thead><tr><th>R\u00e9sultat sur place<\/th><th>V\u00e9rifiez d'abord<\/th><th>Justificatifs requis apr\u00e8s correction<\/th><\/tr><\/thead><tbody><tr><td>Les puissances des trois phases sont toutes n\u00e9gatives lors d'un apport connu vers le r\u00e9seau<\/td><td>Orientation du scanner ou panneau indicateur g\u00e9n\u00e9ral du compteur<\/td><td>Compte rendu de l'orientation physique et impact positif sur la convention convenue<\/td><\/tr><tr><td>Une phase est n\u00e9gative, tandis que deux autres sont positives<\/td><td>Un CT invers\u00e9 ou une combinaison tension\/courant incorrecte<\/td><td>Enregistrement corrig\u00e9 des vecteurs de phase et de la puissance par phase<\/td><\/tr><tr><td>Le courant et le kW diff\u00e8rent d'un facteur constant<\/td><td>R\u00e9glage primaire\/secondaire du CT, entr\u00e9e 1 A\/5 A ou multiplicateur double<\/td><td>Plaque signal\u00e9tique, r\u00e9glages et comparaison du courant de r\u00e9f\u00e9rence<\/td><\/tr><tr><td>La puissance totale en kW est proche de z\u00e9ro en pr\u00e9sence d'une charge \u00e9quilibr\u00e9e importante<\/td><td>Annulation des contributions de phase<\/td><td>V\u00e9rification du signe et de l'angle de phase par phase<\/td><\/tr><tr><td>Le facteur de puissance semble invraisemblable alors que le courant est normal<\/td><td>La phase de tension a \u00e9t\u00e9 attribu\u00e9e au mauvais canal de courant<\/td><td>Combinaison tension\/intensit\u00e9 confirm\u00e9e<\/td><\/tr><tr><td>Le PCS r\u00e9agit, mais le PCC \u00e9volue par la suite ou ne bouge pratiquement pas<\/td><td>Limite incorrecte, charge du site en mouvement ou divergence d'horodatage<\/td><td>\u00c9tape synchronis\u00e9e et contr\u00f4l\u00e9e, avec indication de l'emplacement du compteur<\/td><\/tr><tr><td>La recherche de puissance de lissage des pics s'articule autour de l'objectif<\/td><td>Retard du signal, double filtrage, erreur de signe ou bande morte inadapt\u00e9e<\/td><td>Calendrier de mise \u00e0 jour des donn\u00e9es brutes et tendance stable en boucle ferm\u00e9e<\/td><\/tr><tr><td>L'affichage du compteur et la valeur EMS ne concordent pas<\/td><td>Registre, ordre des octets, unit\u00e9 ou table de mise \u00e0 l'\u00e9chelle<\/td><td>Comparaison c\u00f4te \u00e0 c\u00f4te de l'affichage, du registre et de l'EMS<\/td><\/tr><\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d8b5c3a7 auto-p elementor-widget elementor-widget-heading\" data-id=\"d8b5c3a7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Une puissance active n\u00e9gative peut indiquer un export r\u00e9el, une polarit\u00e9 invers\u00e9e du transformateur de courant ou une convention logicielle invers\u00e9e. Apr\u00e8s chaque modification, r\u00e9p\u00e9tez la m\u00eame proc\u00e9dure contr\u00f4l\u00e9e et conservez la courbe pr\u00e9sentant l'anomalie \u00e0 c\u00f4t\u00e9 de celle qui a \u00e9t\u00e9 corrig\u00e9e.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-62c873d1 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"62c873d1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">O\u00f9 s'arr\u00eate le cabinet ESSA et o\u00f9 commence le comptage sur site ?<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-cf27d615 auto-p elementor-widget elementor-widget-heading\" data-id=\"cf27d615\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Dans l'exemple d'usine de 420 kW, l'ESSA0100B-0215 se connecte \u00e0 un tableau \u00e9lectrique existant de 400 V pour le lissage des pics de consommation. Sa puissance nominale CA publi\u00e9e de 100 kW et son \u00e9nergie nominale de 215,04 kWh caract\u00e9risent l'armoire. L'emplacement du PCC, l'orientation du transformateur de courant (CT) et le calibrage des compteurs sur site font toujours partie du syst\u00e8me \u00e9lectrique install\u00e9.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8895e411 auto-p elementor-widget elementor-widget-heading\" data-id=\"8895e411\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Une inspection phase par phase a r\u00e9v\u00e9l\u00e9 une puissance active n\u00e9gative sur les trois phases d'entr\u00e9e, alors que l'alimentation du r\u00e9seau est connue. Les rapports indiqu\u00e9s sur les plaques signal\u00e9tiques correspondent aux valeurs programm\u00e9es, ce qui conduit \u00e0 s'interroger sur l'orientation physique. Les fl\u00e8ches des transformateurs de courant sont orient\u00e9es dans le sens oppos\u00e9 \u00e0 celui indiqu\u00e9 sur le sch\u00e9ma approuv\u00e9.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9d1c18d8 auto-p elementor-widget elementor-widget-heading\" data-id=\"9d1c18d8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">L'\u00e9quipe \u00e9lectrique corrige l'orientation du transformateur de courant (CT) conform\u00e9ment \u00e0 la proc\u00e9dure d'isolation approuv\u00e9e. La r\u00e9p\u00e9tition de l'\u00e9tape de d\u00e9charge de 20 kW fait d\u00e9sormais passer l'importation du PCC vers 400 kW, tandis qu'une \u00e9tape de charge la fait augmenter. Les chiffres ne servent qu'\u00e0 illustrer la tendance. L'\u00e9volution de la charge du site, les pertes, la pr\u00e9cision des compteurs et le d\u00e9lai d'\u00e9chantillonnage d\u00e9terminent la fourchette de comparaison r\u00e9elle.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-297f3df8 auto-table elementor-widget elementor-widget-text-editor\" data-id=\"297f3df8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"cea-table-wrap\"><table><thead><tr><th>\u00c9tat du test<\/th><th>R\u00e9sultat au sein du gouvernement<\/th><th>Variation pr\u00e9vue du PCC avec une charge stable<\/th><\/tr><\/thead><tbody><tr><td>Commande z\u00e9ro<\/td><td>Puissance active \u00e0 l'int\u00e9rieur de la bande z\u00e9ro d\u00e9finie<\/td><td>Importation de donn\u00e9es de r\u00e9f\u00e9rence<\/td><\/tr><tr><td>Charge contr\u00f4l\u00e9e<\/td><td>La batterie absorbe le courant alternatif<\/td><td>Les importations augmentent<\/td><\/tr><tr><td>D\u00e9charge contr\u00f4l\u00e9e<\/td><td>La batterie fournit du courant alternatif<\/td><td>Baisse des importations<\/td><\/tr><tr><td>Donn\u00e9es de compteur obsol\u00e8tes ou manquantes<\/td><td>EMS suit la solution de secours approuv\u00e9e<\/td><td>Les alarmes, l'\u00e9tat de la qualit\u00e9 des donn\u00e9es et la r\u00e9cup\u00e9ration sont enregistr\u00e9s<\/td><\/tr><\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e600a2c1 auto-p elementor-widget elementor-widget-heading\" data-id=\"e600a2c1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Le <strong><a href=\"https:\/\/www.solidess.com\/fr\/liste-de-controle-pour-le-test-dacceptation-du-site-bess\/\" target=\"_blank\" style=\"color:#61ce70\">Proc\u00e9dure de test de r\u00e9ception sur site du syst\u00e8me BESS<\/a><\/strong> int\u00e8gre le r\u00e9sultat de mesure corrig\u00e9 dans la version globale du site. Il doit faire r\u00e9f\u00e9rence au m\u00eame compteur, au m\u00eame ensemble de transformateurs de courant, au m\u00eame fichier de param\u00e8tres et \u00e0 la m\u00eame courbe de tendance.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-bf062d04 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"bf062d04\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">L\u00e0 o\u00f9 s'ach\u00e8ve le PASS de comptage<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2ba6afb3 auto-p elementor-widget elementor-widget-heading\" data-id=\"2ba6afb3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Un PASS de mesure de bout en bout couvre la cha\u00eene de mesure d\u00e9sign\u00e9e conform\u00e9ment \u00e0 la m\u00e9thode d'essai indiqu\u00e9e. L'acceptation de la capacit\u00e9 comporte une fen\u00eatre SOC distincte, un point de consigne de puissance, une base de temp\u00e9rature, un traitement auxiliaire et un point de mesure CA. Les essais de qualit\u00e9 de l'\u00e9nergie utilisent leur propre emplacement d'analyseur et leurs propres conditions de fonctionnement. Un test de fiabilit\u00e9 r\u00e9alis\u00e9 ult\u00e9rieurement enregistre les alarmes, les restrictions de production et la disponibilit\u00e9.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ed6004b2 auto-p elementor-widget elementor-widget-heading\" data-id=\"ed6004b2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Le <strong><a href=\"https:\/\/www.solidess.com\/fr\/test-de-capacite-du-bess-commercial-pour-verifier-les-kwh-utilisables\/\" target=\"_blank\" style=\"color:#61ce70\">test de capacit\u00e9 des syst\u00e8mes de stockage d'\u00e9nergie par batterie (BESS) \u00e0 usage commercial<\/a><\/strong> couvre le calcul de la consommation d'\u00e9nergie. Un remplacement ult\u00e9rieur du compteur, un changement de transformateur de courant ou une reprogrammation du syst\u00e8me de gestion de l'\u00e9nergie (EMS) entra\u00eene la r\u00e9ouverture des tests de comptage concern\u00e9s, m\u00eame si le mat\u00e9riel de la batterie reste inchang\u00e9.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-bf58533c auto-p elementor-widget elementor-widget-heading\" data-id=\"bf58533c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Lors de la remise, l'op\u00e9rateur a besoin de trois r\u00e9f\u00e9rences correspondantes : <strong>le compteur PCC et le jeu de transformateurs de courant identifi\u00e9s, les param\u00e8tres valid\u00e9s et le dossier logiciel, ainsi que le proc\u00e8s-verbal sign\u00e9 du test de mesure de bout en bout.<\/strong><\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d008bde6 auto-p elementor-widget elementor-widget-heading\" data-id=\"d008bde6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Le signal au niveau de l'armoire et le mode de fonctionnement s\u00e9lectionn\u00e9 doivent correspondre \u00e0 ces trois r\u00e9f\u00e9rences.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2690bf10 elementor-tablet-align-center elementor-align-center auto-cta elementor-widget elementor-widget-button\" data-id=\"2690bf10\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"#elementor-action%3Aaction%3Dpopup%3Aopen%26settings%3DeyJpZCI6Ijk0OCIsInRvZ2dsZSI6ZmFsc2V9\" target=\"_blank\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Contacter MegSolid au sujet de la mise en service des compteurs BESS<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-e8f4e829 auto-faq e-flex e-con-boxed e-con e-child\" data-id=\"e8f4e829\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-e6559ae5 elementor-widget elementor-widget-heading\" data-id=\"e6559ae5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">FAQ<\/h2>\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-f736ef91 e-con-full e-flex e-con e-child\" data-id=\"f736ef91\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-0f9a2363 elementor-widget elementor-widget-n-accordion\" data-id=\"0f9a2363\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;default_state&quot;:&quot;all_collapsed&quot;,&quot;max_items_expended&quot;:&quot;one&quot;,&quot;n_accordion_animation_duration&quot;:{&quot;unit&quot;:&quot;ms&quot;,&quot;size&quot;:400,&quot;sizes&quot;:[]}}\" data-widget_type=\"nested-accordion.default\">\n\t\t\t\t\t\t\t<div class=\"e-n-accordion\" aria-label=\"Accord\u00e9on. Ouvrez les liens \u00e0 l&#039;aide de la touche Entr\u00e9e ou de la barre d&#039;espace, fermez-les avec la touche \u00c9chap et naviguez \u00e0 l&#039;aide des touches fl\u00e9ch\u00e9es.\">\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2610\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"1\" tabindex=\"0\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2610\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> 1. Que se passe-t-il si la polarit\u00e9 du BESS CT est invers\u00e9e ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2610\" class=\"elementor-element elementor-element-bfeaa67f e-con-full e-flex e-con e-child\" data-id=\"bfeaa67f\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2610\" class=\"elementor-element elementor-element-5f4c490d e-con-full e-flex e-con e-child\" data-id=\"5f4c490d\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-1182b94e elementor-widget elementor-widget-heading\" data-id=\"1182b94e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">L'amplitude du courant peut sembler normale alors que la puissance active pr\u00e9sente le signe oppos\u00e9. Un r\u00e9gulateur de lissage des pics ou de z\u00e9ro exportation peut alors envoyer une commande dans le mauvais sens. Mettez le syst\u00e8me en marche et suivez la direction indiqu\u00e9e par les rep\u00e8res du transformateur de courant jusqu'\u00e0 l'\u00e9tiquette du syst\u00e8me de gestion de l'\u00e9nergie (EMS).<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2611\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"2\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2611\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> 2. Une polarit\u00e9 invers\u00e9e du convertisseur de courant alternatif peut-elle entra\u00eener une augmentation des importations du r\u00e9seau lors de la d\u00e9charge du syst\u00e8me de stockage d'\u00e9nergie par batterie (BESS) ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2611\" class=\"elementor-element elementor-element-b4fbbf25 e-con-full e-flex e-con e-child\" data-id=\"b4fbbf25\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2611\" class=\"elementor-element elementor-element-178e7024 e-con-full e-flex e-con e-child\" data-id=\"178e7024\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-cc597290 elementor-widget elementor-widget-heading\" data-id=\"cc597290\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Oui. Le PCS peut effectuer la d\u00e9charge demand\u00e9e alors que le compteur PCC ou le syst\u00e8me EMS la signale avec un signe oppos\u00e9. R\u00e9p\u00e9tez une petite op\u00e9ration de charge et de d\u00e9charge sous une charge constante et observez dans quel sens \u00e9volue l'importation vers le r\u00e9seau.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2612\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"3\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2612\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> 3. Comment v\u00e9rifier la polarit\u00e9 d'un CT en toute s\u00e9curit\u00e9 ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2612\" class=\"elementor-element elementor-element-bbec693a e-con-full e-flex e-con e-child\" data-id=\"bbec693a\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2612\" class=\"elementor-element elementor-element-d4711187 e-con-full e-flex e-con e-child\" data-id=\"d4711187\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-9114e300 elementor-widget elementor-widget-heading\" data-id=\"9114e300\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Le personnel \u00e9lectricien qualifi\u00e9 doit respecter les manuels relatifs aux transformateurs de courant (TC) et aux compteurs, la proc\u00e9dure d\u2019isolation du site ainsi que la r\u00e9glementation \u00e9lectrique locale. Le circuit secondaire d\u2019un TC conventionnel sous tension doit rester ferm\u00e9 pendant toute la dur\u00e9e du court-circuit ou de l\u2019essai pr\u00e9vu. La v\u00e9rification de la pr\u00e9sence de tension s\u2019effectue une fois le circuit r\u00e9tabli en toute s\u00e9curit\u00e9.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2613\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"4\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2613\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> 4. L'injection secondaire permet-elle de v\u00e9rifier le sens du transformateur de courant install\u00e9 ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2613\" class=\"elementor-element elementor-element-7e337417 e-con-full e-flex e-con e-child\" data-id=\"7e337417\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2613\" class=\"elementor-element elementor-element-6049a051 e-con-full e-flex e-con e-child\" data-id=\"6049a051\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-6ff36b37 elementor-widget elementor-widget-heading\" data-id=\"6ff36b37\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">L'injection secondaire couvre les entr\u00e9es en aval, la mise \u00e0 l'\u00e9chelle, la mise en correspondance des phases, les registres et les communications \u00e0 partir du point d'injection. Le sens primaire \u00e0 travers le transformateur de courant (TC) provient alors d'un essai de charge active primaire ou contr\u00f4l\u00e9e du circuit install\u00e9.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2614\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"5\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2614\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> 5. Comment d\u00e9tecte-t-on une erreur de rapport CT lors de la mise en service du BESS ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2614\" class=\"elementor-element elementor-element-b0ce7827 e-con-full e-flex e-con e-child\" data-id=\"b0ce7827\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2614\" class=\"elementor-element elementor-element-7fcdad02 e-con-full e-flex e-con e-child\" data-id=\"7fcdad02\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-f2301597 elementor-widget elementor-widget-heading\" data-id=\"f2301597\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Commencez par v\u00e9rifier la plaque signal\u00e9tique du transformateur de courant ainsi que les r\u00e9glages primaires et secondaires du compteur. V\u00e9rifiez ensuite l'entr\u00e9e 1 A ou 5 A, les unit\u00e9s du protocole et le multiplicateur EMS en les comparant \u00e0 un courant connu sur chaque phase. Une erreur de multiplicateur fixe indique g\u00e9n\u00e9ralement un probl\u00e8me de rapport ou de double mise \u00e0 l'\u00e9chelle.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2615\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"6\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2615\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> 6. Qu'est-ce qu'une erreur d'association de phase en tomodensitom\u00e9trie ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2615\" class=\"elementor-element elementor-element-f5cc39f0 e-con-full e-flex e-con e-child\" data-id=\"f5cc39f0\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2615\" class=\"elementor-element elementor-element-fcb94d52 e-con-full e-flex e-con e-child\" data-id=\"fcb94d52\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-157b4347 elementor-widget elementor-widget-heading\" data-id=\"157b4347\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Le compteur utilise le courant d'une phase et la tension d'une autre. Les valeurs en amp\u00e8res peuvent sembler correctes, mais les valeurs en kW, kvar, le facteur de puissance et l'angle de phase ne correspondront pas. Les relev\u00e9s par phase ou une repr\u00e9sentation sous forme de phaseurs permettent de rep\u00e9rer plus facilement cette divergence.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2616\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"7\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2616\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> 7. O\u00f9 faut-il installer le compteur PCC pour optimiser la gestion des pics de consommation \u00e0 l'\u00e9chelle de l'ensemble du site ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2616\" class=\"elementor-element elementor-element-5d8d8c6f e-con-full e-flex e-con e-child\" data-id=\"5d8d8c6f\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2616\" class=\"elementor-element elementor-element-7b7c9a2e e-con-full e-flex e-con e-child\" data-id=\"7b7c9a2e\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-25026a01 elementor-widget elementor-widget-heading\" data-id=\"25026a01\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Pour un contr\u00f4le de l'ensemble du site, le compteur est g\u00e9n\u00e9ralement install\u00e9 \u00e0 un endroit d'o\u00f9 il peut d\u00e9tecter les \u00e9changes entre le r\u00e9seau et toutes les charges concern\u00e9es, ainsi que les boucles d'alimentation photovolta\u00efques et du syst\u00e8me de stockage par batterie (BESS). Le sch\u00e9ma unifilaire indique l'emplacement exact. Un compteur install\u00e9 uniquement sur la boucle d'alimentation de la batterie mesure la puissance au niveau de l'armoire, et non l'importation totale du site.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2617\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"8\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2617\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> 8. Pourquoi les compteurs PCC et PCS affichent-ils des puissances diff\u00e9rentes ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2617\" class=\"elementor-element elementor-element-0e3f434f e-con-full e-flex e-con e-child\" data-id=\"0e3f434f\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2617\" class=\"elementor-element elementor-element-3091b9bd e-con-full e-flex e-con e-child\" data-id=\"3091b9bd\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-25cd962d elementor-widget elementor-widget-heading\" data-id=\"25cd962d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Les deux compteurs sont raccord\u00e9s \u00e0 des points \u00e9lectriques diff\u00e9rents. Les charges entre eux, les pertes au niveau du transformateur et du c\u00e2ble, les \u00e9quipements auxiliaires, la pr\u00e9cision et la fr\u00e9quence d'\u00e9chantillonnage sont autant de facteurs qui influencent la comparaison. Le test permet de d\u00e9terminer la diff\u00e9rence attendue pour la configuration install\u00e9e.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2618\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"9\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2618\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> 9. Quelle tol\u00e9rance de synchronisation temporelle le test doit-il utiliser ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2618\" class=\"elementor-element elementor-element-cbc98b06 e-con-full e-flex e-con e-child\" data-id=\"cbc98b06\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2618\" class=\"elementor-element elementor-element-f80b1e0d e-con-full e-flex e-con e-child\" data-id=\"f80b1e0d\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-4a82d9c5 elementor-widget elementor-widget-heading\" data-id=\"4a82d9c5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">D\u00e9finissez la tol\u00e9rance en fonction de la r\u00e9ponse de la commande, de la fr\u00e9quence de mise \u00e0 jour du compteur, de l'intervalle de moyennage et de la r\u00e9solution de la tendance. Le r\u00e9sultat n\u00e9cessite \u00e9galement la source de temps, le fuseau horaire et le d\u00e9calage mesur\u00e9. Une boucle d'exportation rapide vers z\u00e9ro et une tendance \u00e9nerg\u00e9tique lente n'utiliseront pas la m\u00eame limite de temps.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2619\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"10\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2619\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> 10. Un compteur peut-il afficher des valeurs plausibles tout en \u00e9tant mal raccord\u00e9 ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2619\" class=\"elementor-element elementor-element-971d9215 e-con-full e-flex e-con e-child\" data-id=\"971d9215\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2619\" class=\"elementor-element elementor-element-0fa89405 e-con-full e-flex e-con e-child\" data-id=\"0fa89405\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-3b9faf9a elementor-widget elementor-widget-heading\" data-id=\"3b9faf9a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Oui. Deux phases correctement orient\u00e9es peuvent masquer une phase invers\u00e9e, et une mauvaise combinaison tension\/courant peut tout de m\u00eame donner des valeurs de courant plausibles. V\u00e9rifiez la tension, le courant, les kW, les kvar, le facteur de puissance et l'angle de phase phase par phase avant de vous fier au total.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-26110\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"11\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-26110\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> 11. Quels \u00e9l\u00e9ments doivent figurer dans le proc\u00e8s-verbal de mise en service des compteurs du syst\u00e8me BESS ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-26110\" class=\"elementor-element elementor-element-6f8052cf e-con-full e-flex e-con e-child\" data-id=\"6f8052cf\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-26110\" class=\"elementor-element elementor-element-6331a51e e-con-full e-flex e-con e-child\" data-id=\"6331a51e\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-f44a0ad0 elementor-widget elementor-widget-heading\" data-id=\"f44a0ad0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Le rapport pr\u00e9cise l'emplacement et le num\u00e9ro de s\u00e9rie du compteur, l'ensemble de transformateurs de courant (CT) et son rapport de transformation, la polarit\u00e9, le couplage des phases, les tensions d'entr\u00e9e, la r\u00e9vision des param\u00e8tres, la carte des registres, la mise \u00e0 l'\u00e9chelle EMS, la convention des signes et la source d'horloge. Ajoutez les mesures de r\u00e9f\u00e9rence, les tendances brutes de charge\/d\u00e9charge et l'autorisation sign\u00e9e.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-26111\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"12\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-26111\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> 12. Une mesure \u00ab PASS \u00bb du syst\u00e8me BESS permet-elle de d\u00e9terminer la quantit\u00e9 de kWh de courant alternatif utilisable ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-26111\" class=\"elementor-element elementor-element-480e3434 e-con-full e-flex e-con e-child\" data-id=\"480e3434\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-26111\" class=\"elementor-element elementor-element-61fdeaaf e-con-full e-flex e-con e-child\" data-id=\"61fdeaaf\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-b7f2b56b elementor-widget elementor-widget-heading\" data-id=\"b7f2b56b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Non. Le r\u00e9sultat de la mesure confirme la cha\u00eene de mesure indiqu\u00e9e. Un test d'\u00e9nergie utilisable d\u00e9finit n\u00e9anmoins ses valeurs limites de SOC, ses limites de courant alternatif, son niveau de puissance, sa base de temp\u00e9rature, son traitement auxiliaire, son intervalle d'\u00e9chantillonnage et sa m\u00e9thode de calcul.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-26112\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"13\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-26112\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> 13. Comment le mod\u00e8le ESSA0100B-0215 se comporte-t-il lors du test de mesure ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-26112\" class=\"elementor-element elementor-element-353cf8f2 e-con-full e-flex e-con e-child\" data-id=\"353cf8f2\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-26112\" class=\"elementor-element elementor-element-9bf1af50 e-con-full e-flex e-con e-child\" data-id=\"9bf1af50\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-5e9b9bf7 elementor-widget elementor-widget-heading\" data-id=\"5e9b9bf7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">L'armoire fournit au projet une interface de 400 V et une puissance nominale en courant alternatif de 100 kW. Les essais sur site portent ensuite sur le compteur PCC externe, les transformateurs de courant, le raccordement au tableau \u00e9lectrique, la cartographie du syst\u00e8me de gestion de l'\u00e9nergie (EMS) et la r\u00e9ponse en boucle ferm\u00e9e mise en place autour de celui-ci.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Une proc\u00e9dure de terrain permettant de v\u00e9rifier l'ensemble de la cha\u00eene de mesure BESS, depuis l'orientation et le rapport des capteurs CT jusqu'\u00e0 la cartographie de phase, la convention des signes et l'alignement temporel.<\/p>","protected":false},"author":4,"featured_media":5190,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"_joinchat":[],"footnotes":""},"categories":[27,1],"tags":[224,543,316,544,184,36,283,545,546],"class_list":["post-5193","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-news","category-bess","tag-bess-commissioning","tag-bess-ct-polarity","tag-ci-bess","tag-ct-ratio","tag-essa0100b-0215","tag-MegSolid","tag-pcc-metering","tag-phase-mapping","tag-power-direction"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/posts\/5193","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/comments?post=5193"}],"version-history":[{"count":1,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/posts\/5193\/revisions"}],"predecessor-version":[{"id":5194,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/posts\/5193\/revisions\/5194"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/media\/5190"}],"wp:attachment":[{"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/media?parent=5193"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/categories?post=5193"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/tags?post=5193"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}