{"id":5268,"date":"2026-09-08T09:36:49","date_gmt":"2026-09-08T01:36:49","guid":{"rendered":"https:\/\/www.solidess.com\/?p=5268"},"modified":"2026-09-08T09:36:49","modified_gmt":"2026-09-08T01:36:49","slug":"grid-scale-battery-storage-australia","status":"publish","type":"post","link":"https:\/\/www.solidess.com\/fr\/grid-scale-battery-storage-australia\/","title":{"rendered":"Stockage d'\u00e9nergie par batterie \u00e0 l'\u00e9chelle du r\u00e9seau en Australie : r\u00e9pondre aux besoins en MW, MWh et POI"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"5268\" class=\"elementor elementor-5268\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-bf4793c e-con-full auto-article-root e-flex e-con e-parent\" data-id=\"bf4793c\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-b23677d6 auto-p elementor-widget elementor-widget-heading\" data-id=\"b23677d6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Quatre <strong><a href=\"https:\/\/www.solidess.com\/fr\/product\/systeme-de-stockage-denergie-conteneurise-megasolid-5000intl\/\" target=\"_blank\" style=\"color:#61ce70\">Blocs de batteries MegSolid 5000INTL<\/a><\/strong> fournissent une puissance nominale de 10,8 MW et une \u00e9nergie nominale de 20,0636 MWh. Les promoteurs qui s'engagent \u00e0 fournir 10 MW pendant deux heures \u00e0 un point d'interconnexion (POI) australien ne disposent que de 63,6 kWh au-del\u00e0 de l'objectif d'\u00e9nergie, avant prise en compte des pertes. V\u00e9rifiez si cette marge couvre la livraison avant de commander les conteneurs, les PCS et les transformateurs.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f20ac429 auto-p elementor-widget elementor-widget-heading\" data-id=\"f20ac429\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">La dur\u00e9e standard d'un bloc est d'environ deux heures. Une autonomie de quatre heures \u00e0 la m\u00eame puissance de sortie n\u00e9cessite davantage d'\u00e9nergie de la batterie, m\u00eame si l'achat de blocs suppl\u00e9mentaires permet \u00e9galement d'augmenter la capacit\u00e9 du PCS.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d88c94de auto-p elementor-widget elementor-widget-heading\" data-id=\"d88c94de\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Les batteries de r\u00e9seau de plus petite taille peuvent commencer par le <strong><a href=\"https:\/\/www.solidess.com\/fr\/product\/systeme-de-stockage-denergie-conteneurise\/\" target=\"_blank\" style=\"color:#61ce70\">Syst\u00e8mes MegSolid de 500 kW \/ 1,0752 MWh et 1 MW \/ 2,1504 MWh<\/a><\/strong>. La troisi\u00e8me phase du projet \u00ab Supernode \u00bb du Queensland, d\u2019une puissance de 260 MW et d\u2019une capacit\u00e9 de 1 216 MWh, illustre ce m\u00eame d\u00e9calage entre la puissance et l\u2019\u00e9nergie \u00e0 une autre \u00e9chelle, et le <strong><a href=\"https:\/\/www.solidess.com\/fr\/supernode-stage-3-bess-sizing\/\" target=\"_blank\" style=\"color:#61ce70\">Calcul des \u00e9quipements des supern\u0153uds<\/a><\/strong> distingue ses chiffres de projet confirm\u00e9s de l'exemple de dimensionnement MegSolid.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-adda165e auto-image elementor-widget elementor-widget-image\" data-id=\"adda165e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"1254\" height=\"1254\" src=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Grid-Scale-Battery-Storage-Australia-MW-and-MWh-Selection.jpg\" class=\"attachment-1536x1536 size-1536x1536 wp-image-5265\" alt=\"Blocs MegSolid 5000INTL illustrant des configurations de batteries \u00e0 l&#039;\u00e9chelle du r\u00e9seau australien pour des dur\u00e9es de deux, quatre et huit heures\" srcset=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Grid-Scale-Battery-Storage-Australia-MW-and-MWh-Selection.jpg 1254w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Grid-Scale-Battery-Storage-Australia-MW-and-MWh-Selection-300x300.jpg 300w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Grid-Scale-Battery-Storage-Australia-MW-and-MWh-Selection-1024x1024.jpg 1024w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Grid-Scale-Battery-Storage-Australia-MW-and-MWh-Selection-150x150.jpg 150w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Grid-Scale-Battery-Storage-Australia-MW-and-MWh-Selection-768x768.jpg 768w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Grid-Scale-Battery-Storage-Australia-MW-and-MWh-Selection-12x12.jpg 12w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Grid-Scale-Battery-Storage-Australia-MW-and-MWh-Selection-600x600.jpg 600w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Grid-Scale-Battery-Storage-Australia-MW-and-MWh-Selection-100x100.jpg 100w\" sizes=\"(max-width: 1254px) 100vw, 1254px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8588924c auto-h2 elementor-widget elementor-widget-heading\" data-id=\"8588924c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Dimensionnement 5000INTL pour une livraison des POI en deux heures<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a09c9d7d auto-p elementor-widget elementor-widget-heading\" data-id=\"a09c9d7d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">MegSolid 5000INTL convient \u00e0 l'\u00e9valuation initiale d'installations constitu\u00e9es de blocs standardis\u00e9s, refroidis par liquide, pour une dur\u00e9e de fonctionnement proche de deux heures. Chaque unit\u00e9 dispose d'une \u00e9nergie nominale de 5,0159 MWh et d'une puissance nominale en courant alternatif de 2,7 MW \u00e0 690 V CA, ce qui correspond \u00e0 environ 1,86 heure selon les caract\u00e9ristiques nominales.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d5485b76 auto-p elementor-widget elementor-widget-heading\" data-id=\"d5485b76\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Comparez ce rapport \u00e0 la dur\u00e9e pr\u00e9vue du contrat afin de d\u00e9terminer s'il convient de dimensionner s\u00e9par\u00e9ment la capacit\u00e9 de la batterie et la puissance du syst\u00e8me de conversion de puissance (PCS).<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f3d59f3f auto-p elementor-widget elementor-widget-heading\" data-id=\"f3d59f3f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Prenons l'exemple d'un projet de 10 MW \/ 20 MWh :<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0516ec99 auto-table elementor-widget elementor-widget-text-editor\" data-id=\"0516ec99\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"cea-table-wrap\"><table><thead><tr><th>Contr\u00f4le de s\u00e9lection<\/th><th>Calcul<\/th><th>R\u00e9sultat<\/th><\/tr><\/thead><tbody><tr><td>Unit\u00e9s requises par puissance<\/td><td>10 MW \u00f7 2,7 MW<\/td><td>3,70 \u2192 4 unit\u00e9s<\/td><\/tr><tr><td>Unit\u00e9s requises par secteur \u00e9nerg\u00e9tique<\/td><td>20 MWh \u00f7 5,0159 MWh<\/td><td>3,99 \u2192 4 unit\u00e9s<\/td><\/tr><tr><td>Plaque signal\u00e9tique \u00e0 quatre unit\u00e9s<\/td><td>4 \u00d7 2,7 MW et 4 \u00d7 5,0159 MWh<\/td><td>10,8 MW \/ 20,0636 MWh<\/td><\/tr><tr><td>\u00c9nergie sup\u00e9rieure \u00e0 l'objectif de 20 MWh<\/td><td>20,0636 \u2212 20 MWh<\/td><td>0,0636 MWh, soit 63,6 kWh<\/td><\/tr><\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b8add159 auto-p elementor-widget elementor-widget-heading\" data-id=\"b8add159\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">La marge \u00e9nerg\u00e9tique des quatre unit\u00e9s est de 0,321 TP5T. Le refroidissement et les syst\u00e8mes de contr\u00f4le y puisent, tout comme les pertes de conversion et de transformation, avant que l'\u00e9nergie n'atteigne le compteur du r\u00e9seau. Le calcul de la production doit \u00e9galement exclure la capacit\u00e9 hors de la plage de SOC op\u00e9rationnelle et tenir compte de la d\u00e9gradation de la capacit\u00e9 au cours de la dur\u00e9e de vie du projet.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2a81b799 auto-p elementor-widget elementor-widget-heading\" data-id=\"2a81b799\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Cinq blocs complets portent la puissance de la centrale \u00e0 13,5 MW \/ 25,0795 MWh. Cette \u00e9nergie suppl\u00e9mentaire offre une marge de livraison accrue, mais s'accompagne d'une capacit\u00e9 PCS suppl\u00e9mentaire de 2,7 MW. \u00c0 un point d\u2019injection (POI) de 10 MW, cette capacit\u00e9 de conversion doit avoir une utilisation bien d\u00e9finie, telle que la redondance ou une autre mission contractuelle, pour justifier son co\u00fbt.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b812bbf5 auto-p elementor-widget elementor-widget-heading\" data-id=\"b812bbf5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">V\u00e9rifiez l'option \u00ab deux heures \u00bb par rapport au test de livraison avant de fixer le nombre de blocs. Des dur\u00e9es de d\u00e9charge plus longues modifient la quantit\u00e9 d'\u00e9nergie de batterie n\u00e9cessaire par MW de puissance du PCS.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6ce8cfb5 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"6ce8cfb5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Une livraison en quatre heures n\u00e9cessite davantage d'\u00e9nergie \u00e0 puissance POI \u00e9gale<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a151e49c auto-p elementor-widget elementor-widget-heading\" data-id=\"a151e49c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Prolonger une d\u00e9charge de 10 MW de deux heures \u00e0 quatre heures n\u00e9cessite deux fois plus d'\u00e9nergie. L'achat de blocs int\u00e9gr\u00e9s complets pour atteindre cet objectif en MWh augmente \u00e9galement la puissance du PCS, m\u00eame si la limite de connexion reste fix\u00e9e \u00e0 10 MW.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d3acfc9b auto-p elementor-widget elementor-widget-heading\" data-id=\"d3acfc9b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">L'appel d'offres n\u00b0 8 du programme australien \u00ab Capacity Investment Scheme \u00bb a retenu 15 projets de batteries totalisant 4,2 GW \/ 16,1 GWh. Ces chiffres cumul\u00e9s correspondent \u00e0 environ 3,83 heures, et l'annonce du gouvernement f\u00e9d\u00e9ral a qualifi\u00e9 ce portefeuille de suffisant pour couvrir pendant quatre heures la pointe de consommation en soir\u00e9e de 3,7 millions de foyers du NEM. Ces attributions devraient entra\u00eener environ 6 milliards de dollars australiens d\u2019investissements priv\u00e9s. (<a href=\"https:\/\/minister.dcceew.gov.au\/bowen\/media-releases\/joint-media-release-big-batteries-power-37-million-australian-households\" target=\"_blank\" rel=\"noopener\">Gouvernement australien, appel d'offres CIS n\u00b0 8<\/a>)<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-693feb58 auto-p elementor-widget elementor-widget-heading\" data-id=\"693feb58\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Ce m\u00eame appel d'offres pr\u00e9voit diff\u00e9rentes dur\u00e9es de stockage. Bulabul 1 est de 300 MW \/ 600 MWh, tandis que Gelston est de 400 MW \/ 1 600 MWh et Moorabool de 300 MW \/ 1 200 MWh. Les exigences de raccordement et de pr\u00e9l\u00e8vement de chaque projet d\u00e9terminent le dimensionnement de ses \u00e9quipements.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f2e2ec87 auto-p elementor-widget elementor-widget-heading\" data-id=\"f2e2ec87\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Pour un POI fixe de 10 MW, le dimensionnement de blocs 5000INTL complets en fonction de leur puissance donne les quantit\u00e9s suivantes :<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1d3901ea auto-table elementor-widget elementor-widget-text-editor\" data-id=\"1d3901ea\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"cea-table-wrap\"><table><thead><tr><th>Frais de livraison<\/th><th>\u00c9nergie n\u00e9cessaire<\/th><th>Blocs 5000INTL complets par \u00e9nergie<\/th><th>Puissance totale des blocs<\/th><th>Cons\u00e9quence en mati\u00e8re de march\u00e9s publics<\/th><\/tr><\/thead><tbody><tr><td>10 MW pendant 2 heures<\/td><td>20 MWh<\/td><td>4<\/td><td>10,8 MW<\/td><td>Les rapports puissance\/\u00e9nergie standard sont proches<\/td><\/tr><tr><td>10 MW pendant 4 heures<\/td><td>40 MWh<\/td><td>8<\/td><td>21,6 MW<\/td><td>11,6 MW de capacit\u00e9 PCS d\u00e9clar\u00e9e d\u00e9passent la limite fix\u00e9e par le POI<\/td><\/tr><tr><td>10 MW pendant 8 heures<\/td><td>80 MWh<\/td><td>16<\/td><td>43,2 MW<\/td><td>Le mode de s\u00e9lection \u00ab \u00c9nergie prioritaire \u00bb ach\u00e8te plus de quatre fois la puissance CA requise<\/td><\/tr><\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-fa7d398e auto-p elementor-widget elementor-widget-heading\" data-id=\"fa7d398e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">L'exemple de 10 MW permet de simplifier les calculs. Utilisez les m\u00eames \u00e9quations pour des points d'int\u00e9r\u00eat (POI) plus importants, en tenant compte du regroupement des \u00e9quipements, du collecteur MT, de la redondance du transformateur principal et du chemin de formation de r\u00e9seau con\u00e7u pour la centrale de plus grande taille.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a01191ac auto-image elementor-widget elementor-widget-image\" data-id=\"a01191ac\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"1448\" height=\"1086\" src=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Two-Hour-vs-Four-Hour-Australian-BESS-Selection.jpg\" class=\"attachment-1536x1536 size-1536x1536 wp-image-5266\" alt=\"Comparaison des quantit\u00e9s de MegSolid 5000INTL pour des applications de batteries de r\u00e9seau de 10 MW d&#039;une dur\u00e9e de deux, quatre et huit heures en Australie\" srcset=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Two-Hour-vs-Four-Hour-Australian-BESS-Selection.jpg 1448w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Two-Hour-vs-Four-Hour-Australian-BESS-Selection-300x225.jpg 300w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Two-Hour-vs-Four-Hour-Australian-BESS-Selection-1024x768.jpg 1024w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Two-Hour-vs-Four-Hour-Australian-BESS-Selection-768x576.jpg 768w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Two-Hour-vs-Four-Hour-Australian-BESS-Selection-16x12.jpg 16w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Two-Hour-vs-Four-Hour-Australian-BESS-Selection-600x450.jpg 600w\" sizes=\"(max-width: 1448px) 100vw, 1448px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d55545ae auto-p elementor-widget elementor-widget-heading\" data-id=\"d55545ae\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Huit blocs complets portent la puissance totale du syst\u00e8me de conversion de puissance (PCS) \u00e0 21,6 MW dans le sc\u00e9nario de quatre heures. V\u00e9rifiez quelle partie de cette capacit\u00e9 de conversion peut \u00eatre utilis\u00e9e par la voie du transformateur. Les pertes au point d\u2019injection (POI) augmentent \u00e9galement l\u2019\u00e9nergie requise par la batterie ; la puissance suppl\u00e9mentaire du PCS ne peut pas compenser les MWh manquants.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-372c8cc6 auto-p elementor-widget elementor-widget-heading\" data-id=\"372c8cc6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">La phase 3 du projet Supernode, dans le Queensland, offre un exemple de comparaison \u00e0 plus grande \u00e9chelle. Sa puissance nominale de 260 MW \/ 1 216 MWh correspond \u00e0 4,68 heures et comprend 176 MWh de plus qu\u2019un simple bloc de 260 MW \u00d7 4 heures. L'utilit\u00e9 de cette marge d\u00e9pend du niveau de charge utile (SOC) du projet, des pertes, de la d\u00e9gradation, de la disponibilit\u00e9 et des exigences de service. Il ne s'agit pas d'un pourcentage de dimensionnement universel.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-54ac6e62 auto-p elementor-widget elementor-widget-heading\" data-id=\"54ac6e62\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">La batterie Limondale de RWE, situ\u00e9e en Nouvelle-Galles du Sud, dispose d\u2019une puissance de charge nominale de 100 MW, d\u2019une puissance de d\u00e9charge de 50 MW et d\u2019une capacit\u00e9 de stockage d\u2019au moins 400 MWh. Son cycle de d\u00e9charge de huit heures utilise un profil de charge plus important. Le planning des \u00e9quipements n\u00e9cessite des entr\u00e9es distinctes pour les MW en charge, les MW en d\u00e9charge et les MWh stock\u00e9s. (<a href=\"https:\/\/www.rwe.com\/en\/press\/rwe-renewables-europe-australia\/2026-05-27-rwe-gets-green-light-to-move-australias-first-eight-hour-battery-to-full-operations\/\" target=\"_blank\" rel=\"noopener\">RWE Limondale BESS<\/a>)<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e5b06c23 auto-p elementor-widget elementor-widget-heading\" data-id=\"e5b06c23\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Les projets visant une puissance de 10 MW au point d\u2019injection (POI) et une fourniture de 40 MWh n\u00e9cessitent un devis distinguant l\u2019\u00e9nergie stock\u00e9e de la conversion en courant alternatif avant que les quantit\u00e9s globales ne deviennent la r\u00e9f\u00e9rence commerciale.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-38f50683 elementor-tablet-align-center elementor-align-center auto-cta elementor-widget elementor-widget-button\" data-id=\"38f50683\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"#elementor-action%3Aaction%3Dpopup%3Aopen%26settings%3DeyJpZCI6Ijk0OCIsInRvZ2dsZSI6ZmFsc2V9\" target=\"_blank\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Contactez MegSolid pour en savoir plus sur le dimensionnement des syst\u00e8mes de stockage d'\u00e9nergie par batterie (BESS) en Australie<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6a3f1165 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"6a3f1165\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Options MegSolid pour diff\u00e9rentes tailles de raccordement<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ac7f3a77 auto-p elementor-widget elementor-widget-heading\" data-id=\"ac7f3a77\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Le bloc de puissance admis par le r\u00e9seau et la fen\u00eatre \u00e9nerg\u00e9tique du contrat orientent le choix de MegSolid. Les projets de distribution de moindre envergure peuvent n\u00e9cessiter une ligne d'alimentation de puissance r\u00e9duite. Les centrales \u00e0 plus longue dur\u00e9e de fonctionnement ont besoin d'un volume plus important en MWh sans augmentation correspondante de la capacit\u00e9 de conversion.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f994152c auto-table elementor-widget elementor-widget-text-editor\" data-id=\"f994152c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"cea-table-wrap\"><table><thead><tr><th>\u00c9tat d'avancement du projet<\/th><th>Parcours d'initiation MegSolid<\/th><th>Note publi\u00e9e<\/th><th>Pourquoi cet itin\u00e9raire est-il adapt\u00e9 ?<\/th><\/tr><\/thead><tbody><tr><td>Centrale de plusieurs m\u00e9gawatts en pr\u00e8s de deux heures<\/td><td>5000INTL<\/td><td>2,7 MW \/ 5,0159 MWh<\/td><td>Un bloc r\u00e9utilisable \u00e0 refroidissement par liquide permet d'int\u00e9grer l'\u00e9nergie provenant de la batterie et l'alimentation en courant alternatif dans un m\u00eame sch\u00e9ma d'\u00e9quipement<\/td><\/tr><tr><td>Batterie FTM de petite taille raccord\u00e9e au r\u00e9seau de distribution<\/td><td>ESSC0500B-1075<\/td><td>500 kW \/ 1,0752 MWh<\/td><td>Une puissance d'alimentation r\u00e9duite permet de mener \u00e0 bien des projets par \u00e9tapes sans devoir commencer par un bloc de 2,7 MW<\/td><\/tr><tr><td>Projet de distribution d'un m\u00e9gawatt<\/td><td>ESSC1000B-2150<\/td><td>1 MW \/ 2,1504 MWh<\/td><td>Un syst\u00e8me g\u00e9n\u00e8re une p\u00e9riode nominale d'un peu plus de deux heures<\/td><\/tr><tr><td>Projet n\u00e9cessitant une attribution distincte de la puissance PCS<\/td><td>MEGA0500TS PCS<\/td><td>500 kW nominaux \/ 550 kVA maximum<\/td><td>La quantit\u00e9 de convertisseurs peut \u00eatre d\u00e9termin\u00e9e en fonction de la puissance active et r\u00e9active, plut\u00f4t qu\u2019en fonction du nombre de conteneurs de batteries.<\/td><\/tr><\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e29bd1f9 auto-p elementor-widget elementor-widget-heading\" data-id=\"e29bd1f9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">MegSolid \u00e9quipe le mod\u00e8le 5000INTL d'un syst\u00e8me de refroidissement liquide intelligent pour le bloc de 5,0159 MWh, d'un bo\u00eetier IP55, d'un syst\u00e8me d'alerte pr\u00e9coce assist\u00e9 par IA et d'une protection tridimensionnelle. V\u00e9rifiez les performances de refroidissement en cas de mises en service r\u00e9p\u00e9t\u00e9es et assurez-vous que les op\u00e9rateurs sont en mesure d'identifier les alarmes parmi les unit\u00e9s en parall\u00e8le.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3ef89fbb auto-p elementor-widget elementor-widget-heading\" data-id=\"3ef89fbb\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Ces deux mod\u00e8les ESSC conviennent aux projets qui se raccordent \u00e0 un niveau de puissance inf\u00e9rieur ou qui s'\u00e9tendent par \u00e9tapes planifi\u00e9es. L'ESSC0500B-1075 utilise une configuration de 500 kW \/ 1,0752 MWh ; l'ESSC1000B-2150 double ces deux valeurs pour atteindre 1 MW \/ 2,1504 MWh. Les deux mod\u00e8les sont \u00e9quip\u00e9s d\u2019un refroidissement par air \u00e0 temp\u00e9rature contr\u00f4l\u00e9e et de bo\u00eetiers IP54. Le choix est d\u00e9termin\u00e9 par la capacit\u00e9 des lignes d\u2019alimentation et la disposition des transformateurs, ainsi que par les \u00e9tapes d\u2019installation pr\u00e9vues. La comparaison doit \u00e9galement mettre en \u00e9vidence la perte de capacit\u00e9 de la centrale lorsqu\u2019un bloc est \u00e0 l\u2019arr\u00eat pour maintenance.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7ef64f44 auto-p elementor-widget elementor-widget-heading\" data-id=\"7ef64f44\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Envisagez le MEGA0500TS lorsque le projet n\u00e9cessite un dimensionnement distinct du syst\u00e8me de contr\u00f4le de puissance (PCS). Sa puissance nominale de 500 kW, sa puissance maximale de 550 kVA et sa plage de tension continue de 500 \u00e0 850 V permettent \u00e0 l'ing\u00e9nieur d'\u00e9tudier simultan\u00e9ment la puissance active, la marge de puissance r\u00e9active et la tension de la batterie. Le <strong><a href=\"https:\/\/www.solidess.com\/fr\/product\/systeme-de-conversion-denergie-megsolid\/\" target=\"_blank\" style=\"color:#61ce70\">Gamme MegSolid MEGA TS PCS<\/a><\/strong> comprend \u00e9galement des classes de puissance plus petites, ce qui permet \u00e0 un projet de choisir une puissance de conversion adapt\u00e9e \u00e0 sa charge \u00e9lectrique plut\u00f4t que de consid\u00e9rer un conteneur comme l'unit\u00e9 de conception la plus petite.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f39fd707 auto-p elementor-widget elementor-widget-heading\" data-id=\"f39fd707\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Comparez les co\u00fbts pour un m\u00eame taux de service. Le cycle de fonctionnement, les \u00e9quipements auxiliaires, la marge de d\u00e9gradation et la strat\u00e9gie de remplacement ont une incidence sur l'\u00e9nergie fournie sur toute la dur\u00e9e de vie, qui constitue la base de la <strong><a href=\"https:\/\/www.solidess.com\/fr\/bess-lcos-lifetime-cost-per-delivered-kwh\/\" target=\"_blank\" style=\"color:#61ce70\">M\u00e9thode de calcul du co\u00fbt sur toute la dur\u00e9e de vie du syst\u00e8me BESS par kWh fourni<\/a><\/strong>.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-66ea931a auto-h2 elementor-widget elementor-widget-heading\" data-id=\"66ea931a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Le chemin du transformateur d\u00e9termine ce qui parvient au point d'int\u00e9r\u00eat (POI)<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a3fb0c62 auto-p elementor-widget elementor-widget-heading\" data-id=\"a3fb0c62\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Les quantit\u00e9s de conteneurs d\u00e9pendent de l\u2019endroit o\u00f9 le projet mesure la r\u00e9ception. Dans une installation situ\u00e9e en amont du compteur, les pertes de conversion et les charges du site entre la batterie et le compteur reli\u00e9 au r\u00e9seau r\u00e9duisent l\u2019\u00e9nergie fournie.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-34d98efa auto-p elementor-widget elementor-widget-heading\" data-id=\"34d98efa\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">L'installation n\u00e9cessite un circuit \u00e9lectrique vers le point d'int\u00e9r\u00eat (POI), avec des commandes et des dispositifs de mesure pour la production combin\u00e9e :<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0cc947cb elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"0cc947cb\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">1. Les blocs de batteries stockent l'\u00e9nergie en courant continu et garantissent le respect des limites de fonctionnement des cellules.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">2. \u00c9quipements PCS assurant la gestion de la charge, de la d\u00e9charge et de la r\u00e9ponse r\u00e9active.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">3. Des transformateurs d'unit\u00e9 qui \u00e9l\u00e8vent la tension de sortie du convertisseur au niveau de la tension du collecteur.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">4. Les alimentations par collecteur et les appareillages de commutation regroupant les blocs en zones prot\u00e9g\u00e9es.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">5. Le transformateur principal et les \u00e9quipements POI assurant le raccordement de l'ensemble de l'installation au r\u00e9seau.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">6. Le contr\u00f4leur de la centrale et le comptage des recettes permettent de transformer la limite de raccordement en un objectif d'exploitation mesurable.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1282d942 auto-image elementor-widget elementor-widget-image\" data-id=\"1282d942\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"1448\" height=\"1086\" src=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Australian-Front-of-Meter-BESS-Connection-to-the-POI.jpg\" class=\"attachment-1536x1536 size-1536x1536 wp-image-5267\" alt=\"Blocs de batteries MegSolid raccord\u00e9s, via le PCS, les transformateurs d&#039;unit\u00e9, l&#039;appareillage de collecte et le transformateur principal, \u00e0 un point d&#039;interconnexion du r\u00e9seau australien\" srcset=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Australian-Front-of-Meter-BESS-Connection-to-the-POI.jpg 1448w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Australian-Front-of-Meter-BESS-Connection-to-the-POI-300x225.jpg 300w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Australian-Front-of-Meter-BESS-Connection-to-the-POI-1024x768.jpg 1024w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Australian-Front-of-Meter-BESS-Connection-to-the-POI-768x576.jpg 768w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Australian-Front-of-Meter-BESS-Connection-to-the-POI-16x12.jpg 16w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Australian-Front-of-Meter-BESS-Connection-to-the-POI-600x450.jpg 600w\" sizes=\"(max-width: 1448px) 100vw, 1448px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3fc9794a auto-p elementor-widget elementor-widget-heading\" data-id=\"3fc9794a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Le MegSolid 5000INTL fournit une puissance nominale en courant alternatif de 690 Vca. Une batterie australienne \u00e0 l'\u00e9chelle du r\u00e9seau acheminera cette puissance vers le transformateur et le dispositif de collecte choisis pour le site. La tension au point d'injection (POI), la limite d'injection, la limite de charge et la puissance r\u00e9active d\u00e9terminent alors quelle partie des blocs combin\u00e9s de 2,7 MW peut fonctionner simultan\u00e9ment.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8d299cfd auto-p elementor-widget elementor-widget-heading\" data-id=\"8d299cfd\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Dix blocs 5000INTL fournissent une puissance nominale en courant alternatif de 27 MW, ce qui d\u00e9passe la capacit\u00e9 d'un transformateur de 25 MVA, m\u00eame avec un facteur de puissance unitaire. La demande r\u00e9active mobilise une capacit\u00e9 suppl\u00e9mentaire en MVA. L'\u00e9tude de charge doit prendre en compte les valeurs en kW, kvar et kVA en fonction de la temp\u00e9rature du transformateur, de la position des prises, des situations d'urgence et du mode de commande \u00e9valu\u00e9s.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c32e5eb9 auto-p elementor-widget elementor-widget-heading\" data-id=\"c32e5eb9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Les appareillages de commutation doivent \u00eatre adapt\u00e9s \u00e0 la tension et au courant continu dans les deux sens. Leur capacit\u00e9 de r\u00e9sistance aux courts-circuits, la s\u00e9lectivit\u00e9 de la protection et le dispositif d\u2019isolation doivent \u00e9galement \u00eatre v\u00e9rifi\u00e9s. Le <strong><a href=\"https:\/\/www.solidess.com\/fr\/connexion-de-batterie-400-v-au-tableau-electrique-existant\/\" target=\"_blank\" style=\"color:#61ce70\">M\u00e9thode de raccordement au tableau \u00e9lectrique BESS<\/a><\/strong> explique ces contr\u00f4les \u00e0 basse tension, et ce m\u00eame principe s'applique aux \u00e9quipements de collecte et aux postes de transformation \u00e0 moyenne tension d'une centrale de plus grande envergure.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d3b7f1b9 auto-p elementor-widget elementor-widget-heading\" data-id=\"d3b7f1b9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">La localisation g\u00e9ographique du march\u00e9 influe \u00e9galement sur le p\u00e9rim\u00e8tre du projet. Les projets relevant du NEM s'inscrivent dans le cadre de l'AEMO et suivent la proc\u00e9dure de raccordement au r\u00e9seau applicable, tandis que les projets de l'Australie-Occidentale rel\u00e8vent du WEM et des dispositions locales en mati\u00e8re de r\u00e9seau. Le <a href=\"https:\/\/www.aemo.com.au\/initiatives\/major-programs\/nem-reform-program\/nem-reform-program-initiatives\/integrating-energy-storage-systems-project\" target=\"_blank\" rel=\"noopener\">Projet de l'AEMO sur l'int\u00e9gration des syst\u00e8mes de stockage d'\u00e9nergie<\/a> montre comment le stockage bidirectionnel est pris en compte lors de l'enregistrement, de la r\u00e9partition et du comptage. La tarification des conteneurs doit \u00eatre bas\u00e9e sur le march\u00e9, le r\u00e9seau et le point d'int\u00e9r\u00eat (POI) identifi\u00e9s.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-cc4c22eb auto-h2 elementor-widget elementor-widget-heading\" data-id=\"cc4c22eb\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Horaires de distribution et services concurrents<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c692bc1d auto-p elementor-widget elementor-widget-heading\" data-id=\"c692bc1d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Les livraisons en soir\u00e9e, le commerce de gros et les interventions rapides du FCAS peuvent n\u00e9cessiter des marges SOC diff\u00e9rentes pour une centrale pr\u00e9sentant les m\u00eames puissances nominales en MW et en MWh. Utilisez le programme de r\u00e9partition pour calculer la charge thermique, le d\u00e9bit annuel et la r\u00e9serve.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4b7c77bc elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"4b7c77bc\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Le CIS (Contrat d'approvisionnement en \u00e9lectricit\u00e9) ou les r\u00e9servations de livraison en soir\u00e9e permettent de pr\u00e9server l'\u00e9nergie pour une plage horaire donn\u00e9e. Les MWh en fin de cycle de vie et la disponibilit\u00e9 au point d'int\u00e9r\u00eat (POI) ont plus de poids que la capacit\u00e9 \u00e0 suivre chaque fluctuation, aussi minime soit-elle, des prix.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">L'arbitrage de gros intensifie les op\u00e9rations de charge et de d\u00e9charge en fonction de l'\u00e9volution des \u00e9carts de prix. Le mod\u00e8le d'exploitation doit reposer sur des hypoth\u00e8ses r\u00e9alistes en mati\u00e8re d'efficacit\u00e9, de consommation auxiliaire et de cycles de fonctionnement.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Le syst\u00e8me FCAS exploite une r\u00e9ponse de contr\u00f4le rapide et peut faire varier \u00e0 plusieurs reprises l'\u00e9tat de charge (SOC) de la batterie autour de sa valeur cible. La puissance disponible est importante, mais le syst\u00e8me de gestion de l'\u00e9nergie (EMS) doit \u00e9galement disposer d'une marge d'\u00e9nergie suffisante pour \u00e9viter de bloquer l'instruction suivante.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">L'assistance r\u00e9seau lie la disponibilit\u00e9 \u00e0 un lieu, \u00e0 une plage horaire et \u00e0 une interface de contr\u00f4le convenus avec le r\u00e9seau. Le non-respect de cette plage horaire peut avoir des cons\u00e9quences plus importantes que la consommation \u00e9nerg\u00e9tique annuelle totale.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Le renforcement solaire ou \u00e9olien \u00e9tablit un lien entre la charge de la batterie, la production d'\u00e9nergie renouvelable, la r\u00e9duction de la production et le plafond d'exportation partag\u00e9. L'\u00e9nergie disponible pour la charge peut devenir le facteur limitant, m\u00eame lorsque la batterie est vide.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2325237d auto-p elementor-widget elementor-widget-heading\" data-id=\"2325237d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">L'\u00e9tude comparative men\u00e9e par Gridcog en Australie a mis en \u00e9vidence des diff\u00e9rences dans les mod\u00e8les de revenus et d'exploitation entre les actifs mod\u00e9lis\u00e9s selon les principes du NEM et ceux du WEM. La volatilit\u00e9 du march\u00e9 de gros a favoris\u00e9 le sc\u00e9nario FTM du NEM, tandis que le mod\u00e8le WEM int\u00e9grait des cr\u00e9dits de capacit\u00e9. Il convient d'utiliser un historique de r\u00e9partition du projet pour d\u00e9terminer l'intensit\u00e9 et la fr\u00e9quence des cycles, et d'attribuer la priorit\u00e9 aux services qui se disputent la m\u00eame capacit\u00e9. (<a href=\"https:\/\/www.gridcog.com\/blog\/maximising-battery-value-a-commercial-analysis-of-front-of-meter-vs-behind-the-meter-storage\" target=\"_blank\" rel=\"noopener\">Analyse FTM et BTM de Gridcog<\/a>)<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5af89be3 auto-p elementor-widget elementor-widget-heading\" data-id=\"5af89be3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">V\u00e9rifiez le suivi de l'exp\u00e9dition par rapport au rapport nominal de 1,86 heure du 5000INTL, \u00e0 la plage de fonctionnement garantie et aux conditions de d\u00e9bit. Planifiez la maintenance en fonction de la disponibilit\u00e9 pr\u00e9vue dans le contrat, et v\u00e9rifiez les performances du refroidissement par liquide ainsi que les fonctions d'alerte pr\u00e9coce pour un fonctionnement r\u00e9p\u00e9t\u00e9 sur l'ensemble du r\u00e9seau.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-97fc4dee auto-p elementor-widget elementor-widget-heading\" data-id=\"97fc4dee\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">La fourniture en soir\u00e9e peut n\u00e9cessiter de conserver de l'\u00e9nergie dans la batterie, alors qu'une opportunit\u00e9 d'arbitrage exige au contraire une d\u00e9charge. La marge de man\u0153uvre du FCAS peut \u00e9galement entrer en concurrence avec un programme d'exportation complet de 10 MW. La stabilisation des \u00e9nergies renouvelables ajoute une contrainte de charge : un vent faible ou une couverture nuageuse peuvent supprimer la fen\u00eatre de charge pr\u00e9vue. Le mod\u00e8le d'exploitation doit d\u00e9finir des priorit\u00e9s et pr\u00e9voir des r\u00e9serves pour g\u00e9rer ces conflits avant de regrouper les revenus.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b13b27c9 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"b13b27c9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">R\u00e9ponse de PCS dans le cadre de l'\u00e9tude sur les connexions en Australie<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-66305d02 auto-p elementor-widget elementor-widget-heading\" data-id=\"66305d02\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Les \u00e9tudes sur les interconnexions australiennes examinent la mani\u00e8re dont l'ensemble de la centrale r\u00e9agit aux ordres de puissance active, \u00e0 la demande de puissance r\u00e9active et aux perturbations, y compris les interactions entre les convertisseurs sous le contr\u00f4le d'un seul syst\u00e8me de commande de la centrale. Le champ d'application de l'\u00e9tude couvre :<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-597474f1 elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"597474f1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">contr\u00f4le de la puissance active, vitesses de mont\u00e9e en puissance et limites de charge\/d\u00e9charge ;<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">capacit\u00e9 en puissance r\u00e9active sur toute la plage de fonctionnement pr\u00e9vue ;<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">r\u00e9ponse en tension et en fr\u00e9quence ;<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">logique de maintien en fonctionnement en cas de d\u00e9faut et de priorit\u00e9 au courant ;<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">performance harmonique au POI ;<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">la coordination entre les unit\u00e9s PCS et le contr\u00f4leur de l'usine ;<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">r\u00e9ponse de protection et comportement en cas de perte de communication.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b894ae70 auto-p elementor-widget elementor-widget-heading\" data-id=\"b894ae70\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Le MEGA0500TS offre une puissance nominale de 500 kW, une puissance maximale de 550 kVA, une plage de tension continue comprise entre 500 et 850 V et un rendement maximal de 97,5%. Utilisez la valeur maximale de 550 kVA pour \u00e9valuer la capacit\u00e9 active et r\u00e9active, dans le respect des limites de fonctionnement approuv\u00e9es. L'enveloppe P\/Q finale doit correspondre au point de fonctionnement s\u00e9lectionn\u00e9, \u00e0 la puissance nominale du transformateur et aux exigences du r\u00e9seau.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-30fb241a auto-p elementor-widget elementor-widget-heading\" data-id=\"30fb241a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Les harmoniques se situent \u00e9galement au niveau de la limite de raccordement au r\u00e9seau. La longueur des c\u00e2bles, les transformateurs, les distorsions de fond et les interactions entre convertisseurs en parall\u00e8le peuvent modifier le r\u00e9sultat entre les terminaux PCS et le point d\u2019injection (POI). Le <strong><a href=\"https:\/\/www.solidess.com\/fr\/tests-de-qualite-de-lenergie-pour-la-reception-commerciale-des-systemes-de-stockage-denergie-par-batterie\/\" target=\"_blank\" style=\"color:#61ce70\">M\u00e9thode de r\u00e9ception de la qualit\u00e9 de l'\u00e9nergie BESS<\/a><\/strong> associe les mesures de kW, kvar, facteur de puissance et d'harmoniques \u00e0 un compteur, un \u00e9tat de fonctionnement et un enregistrement temporel.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-153e4a18 auto-p elementor-widget elementor-widget-heading\" data-id=\"153e4a18\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">L'AEMO exige que les mod\u00e8les de raccordement refl\u00e8tent l'installation en service. Le dossier R1 concerne la mise en service, tandis que les donn\u00e9es valid\u00e9es du dossier R2 consignent les r\u00e9glages d\u00e9finitifs et la r\u00e9ponse test\u00e9e. Le mod\u00e8le du convertisseur, la version du contr\u00f4leur, les donn\u00e9es relatives au transformateur et les limites de courant doivent rester coh\u00e9rents depuis l'\u00e9tude de raccordement jusqu'\u00e0 la configuration en usine et aux essais sur site. (<a href=\"https:\/\/www.aemo.com.au\/energy-systems\/electricity\/national-electricity-market-nem\/participate-in-the-market\/network-connections\/modelling-requirements\" target=\"_blank\" rel=\"noopener\">Exigences de mod\u00e9lisation de l'AEMO<\/a>)<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-75989680 auto-p elementor-widget elementor-widget-heading\" data-id=\"75989680\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">L'exploitation en tant que dispositif de stabilisation du r\u00e9seau implique une d\u00e9cision suppl\u00e9mentaire. ARENA a indiqu\u00e9 en novembre 2025 que cinq batteries de formation de r\u00e9seau b\u00e9n\u00e9ficiant d\u2019un soutien avaient \u00e9t\u00e9 raccord\u00e9es au NEM, et les premiers projets ont montr\u00e9 comment les mod\u00e8les de contr\u00f4le et les normes de performance n\u00e9goci\u00e9es influencent la mise en \u0153uvre. La phase 3 du programme Supernode a ensuite int\u00e9gr\u00e9 les syst\u00e8mes de contr\u00f4le de puissance (PCS) de formation de r\u00e9seau, les contr\u00f4les des centrales, l\u2019int\u00e9gration et le soutien au raccordement au r\u00e9seau dans le p\u00e9rim\u00e8tre de GE Vernova. (<a href=\"https:\/\/arena.gov.au\/blog\/australias-grid-forming-battery-revolution-from-pilot-projects-to-global-leadership\/\" target=\"_blank\" rel=\"noopener\">Test de la batterie de stabilisation du r\u00e9seau ARENA<\/a>)<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7d617adf auto-p elementor-widget elementor-widget-heading\" data-id=\"7d617adf\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Le PCS, le contr\u00f4leur de l'installation et le mod\u00e8le de raccordement doivent \u00eatre coh\u00e9rents quant au comportement de suivi du r\u00e9seau ou de formation du r\u00e9seau. Le bloc d'\u00e9nergie 5000INTL s\u00e9lectionn\u00e9 doit ensuite \u00eatre \u00e9valu\u00e9 dans le cadre de cette configuration. Le <strong><a href=\"https:\/\/www.solidess.com\/fr\/systeme-de-secours-a-batterie-raccorde-au-reseau-pourquoi-le-systeme-bess-se-met-hors-tension-en-cas-de-coupure-de-courant\/\" target=\"_blank\" style=\"color:#61ce70\">Explication du contr\u00f4le de suivi et de formation du r\u00e9seau<\/a><\/strong> montre pourquoi l'\u00e9nergie stock\u00e9e et la r\u00e9gulation de la tension alternative doivent \u00eatre consid\u00e9r\u00e9es comme des capacit\u00e9s distinctes.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f5017de0 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"f5017de0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">MWh fournis au compteur contractuel<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c986275c auto-p elementor-widget elementor-widget-heading\" data-id=\"c986275c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">L'exigence relative aux MWh fournis n\u00e9cessite l'indication d'un compteur sp\u00e9cifique et de l'ann\u00e9e contractuelle. Partant de la capacit\u00e9 nominale de la batterie, le calcul tient compte de la consommation du syst\u00e8me de contr\u00f4le de puissance (PCS), des transformateurs, du syst\u00e8me de capteurs et des \u00e9quipements auxiliaires de la centrale.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7560b363 auto-p elementor-widget elementor-widget-heading\" data-id=\"7560b363\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Calculez l'\u00e9nergie du POI dans l'ordre suivant :<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d097f3a7 auto-p elementor-widget elementor-widget-heading\" data-id=\"d097f3a7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\"><code>\u00c9nergie de la batterie install\u00e9e \u2192 plage de SOC utilisable \u2192 capacit\u00e9 conserv\u00e9e \u2192 puissance de sortie du PCS \u2192 pertes au niveau du transformateur et du collecteur \u2192 \u00e9nergie POI<\/code><\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d18450c6 auto-p elementor-widget elementor-widget-heading\" data-id=\"d18450c6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Les pompes de refroidissement, les syst\u00e8mes de commande, les syst\u00e8mes anti-incendie, les appareils de chauffage et les charges des postes de transformation consomment \u00e9galement de l'\u00e9nergie pendant la p\u00e9riode de fourniture. Leur prise en compte doit \u00eatre conforme \u00e0 la m\u00e9thode de comptage et de r\u00e9ception d\u00e9finie pour le projet. Dans l'exemple de quatre unit\u00e9s de 10 MW \/ 20 MWh, la consommation auxiliaire est pr\u00e9lev\u00e9e sur la marge nominale de 63,6 kWh, au m\u00eame titre que d'autres pertes.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-19135eaf auto-p elementor-widget elementor-widget-heading\" data-id=\"19135eaf\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">MegSolid indique 87,51 TP5T comme rendement maximal pour le mod\u00e8le 5000INTL. Utilisez cette valeur dans les limites sp\u00e9cifi\u00e9es pour l'\u00e9quipement. Avant de l'int\u00e9grer dans le calcul du rendement aller-retour d'un projet, d\u00e9terminez quelles pertes de charge et de d\u00e9charge elle couvre afin qu'elles ne soient pas compt\u00e9es deux fois. Le mod\u00e8le POI n\u00e9cessite des valeurs distinctes pour le circuit de la batterie, le convertisseur, les transformateurs, le collecteur et les \u00e9quipements auxiliaires, en fonction de la puissance et de la temp\u00e9rature pr\u00e9vues.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a223ef6f auto-p elementor-widget elementor-widget-heading\" data-id=\"a223ef6f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">La \u00ab Waratah Super Battery \u00bb illustre l\u2019impact commercial du circuit en courant alternatif. Cette centrale situ\u00e9e en Nouvelle-Galles du Sud affiche une puissance nominale de 850 MW \/ 1 680 MWh et une capacit\u00e9 garantie d\u2019au moins 700 MW \/ 1 400 MWh. Une d\u00e9faillance du transformateur haute tension a limit\u00e9 son exploitation lors de la mise en service ; Akaysha a annonc\u00e9 une mise en service de 700 MW en juin 2026, le transformateur haute tension n\u00b0 3 \u00e9tant n\u00e9cessaire pour atteindre la pleine capacit\u00e9 de 850 MW de la centrale et assurer l'int\u00e9gralit\u00e9 du service SIPS de 700 MW. (<a href=\"https:\/\/akayshaenergy.com\/news\/waratah-super-battery-now-operating-at-700mw\" target=\"_blank\" rel=\"noopener\">Actualit\u00e9s concernant Akaysha Energy et Waratah<\/a>)<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2aee19ee auto-p elementor-widget elementor-widget-heading\" data-id=\"2aee19ee\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Int\u00e9grer la disponibilit\u00e9 des transformateurs dans la garantie de livraison MegSolid. M\u00eame si les cellules et les \u00e9quipements PCS sont pr\u00eats, la centrale a besoin d'un circuit de transformateur op\u00e9rationnel pour assurer la livraison au point d'injection (POI).<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1ebdc814 auto-p elementor-widget elementor-widget-heading\" data-id=\"1ebdc814\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Veuillez distinguer ces valeurs \u00e9nerg\u00e9tiques dans le calendrier d'approvisionnement :<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-30042fc3 elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"30042fc3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Puissance nominale : valeur indiqu\u00e9e sur la plaque signal\u00e9tique de la batterie install\u00e9e.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">\u00c9nergie utilisable : la partie disponible dans les limites du SOC et d'exploitation approuv\u00e9es.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Livraison au d\u00e9but et \u00e0 la fin du cycle de vie : le r\u00e9sultat exploitable au cours de l'ann\u00e9e contractuelle indiqu\u00e9e.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">\u00c9nergie au point d'injection : le MWh d'\u00e9lectricit\u00e9 alternative (AC) passant par le compteur convenu, apr\u00e8s d\u00e9duction des pertes du projet et de la consommation des \u00e9quipements auxiliaires.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a18e77dd auto-p elementor-widget elementor-widget-heading\" data-id=\"a18e77dd\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Appliquer les marges relatives \u00e0 la fen\u00eatre d'exploitation, au vieillissement, aux pertes et \u00e0 la disponibilit\u00e9 au bloc de 5,0159 MWh par 5 000 INTL. Comparer l'\u00e9nergie POI restante aux exigences du test contractuel avant de d\u00e9cider s'il convient d'augmenter la capacit\u00e9.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-225a8efe auto-h2 elementor-widget elementor-widget-heading\" data-id=\"225a8efe\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Acc\u00e8s aux conteneurs, intervention en cas d'incendie et livraison<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6095d104 auto-p elementor-widget elementor-widget-heading\" data-id=\"6095d104\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">La surface disponible doit \u00eatre suffisante pour accueillir bien plus que les conteneurs. Les voies d'acc\u00e8s pour les pompiers, le syst\u00e8me de drainage et les espaces n\u00e9cessaires \u00e0 l'entretien occupent de la place, tandis que l'itin\u00e9raire de livraison peut limiter les emplacements possibles pour le mat\u00e9riel.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d2523788 auto-p elementor-widget elementor-widget-heading\" data-id=\"d2523788\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">MegSolid publie les cotes 5000INTL de 6 058 \u00d7 2 438 \u00d7 2 896 mm. La r\u00e9p\u00e9tition de cet encombrement sur un vaste r\u00e9seau fournit au concepteur en g\u00e9nie civil une base pr\u00e9liminaire pour l\u2019implantation des rang\u00e9es, le trac\u00e9 des c\u00e2bles et l\u2019acc\u00e8s aux installations techniques. Obtenez le plan de transport d\u00e9finitif, les points de levage, les charges d\u2019ancrage et les d\u00e9gagements n\u00e9cessaires aux \u00e9quipements avant de d\u00e9finir l\u2019emplacement des voies d\u2019acc\u00e8s, des plates-formes et des grues.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-dae719c4 auto-p elementor-widget elementor-widget-heading\" data-id=\"dae719c4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Les recommandations de l\u2019AFAC pour 2025 demandent aux d\u00e9veloppeurs australiens de syst\u00e8mes de stockage d\u2019\u00e9nergie par batterie (BESS) raccord\u00e9s au r\u00e9seau d\u2019\u00e9laborer une strat\u00e9gie globale de s\u00e9curit\u00e9 incendie et de collaborer avec les services d\u2019incendie et d\u2019urgence comp\u00e9tents pour la zone du projet. Les interventions en cas d\u2019incendie et les risques d\u2019inondation ont tous deux une incidence sur le site. Le plan d\u2019implantation doit indiquer comment les \u00e9quipes interviennent en cas d\u2019incident, isolent les \u00e9quipements et g\u00e8rent les \u00e9coulements sans traverser de zone \u00e9lectrique dangereuse. (<a href=\"https:\/\/afac.com.au\/resources\/large-scale-battery-energy-storage-system-installations\" target=\"_blank\" rel=\"noopener\">Recommandations de l'AFAC concernant les syst\u00e8mes de stockage d'\u00e9nergie par batterie (BESS) \u00e0 grande \u00e9chelle<\/a>)<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-aa5e637f auto-p elementor-widget elementor-widget-heading\" data-id=\"aa5e637f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Les \u00e9quipes civiles et d\u2019intervention d\u2019urgence doivent v\u00e9rifier l\u2019acc\u00e8s des v\u00e9hicules aux zones d\u2019intervention ainsi que l\u2019itin\u00e9raire permettant de d\u00e9gager un bloc isol\u00e9 apr\u00e8s la mise sous tension. Cartographier les voies d\u2019\u00e9coulement de l\u2019eau d\u2019extinction et des eaux de ruissellement contamin\u00e9es, puis \u00e9valuer l\u2019exposition \u00e0 la fum\u00e9e et \u00e0 la chaleur des blocs adjacents et des riverains en fonction des vents dominants. V\u00e9rifier que le port, l\u2019itin\u00e9raire routier, la zone de stockage et la grue sont conformes \u00e0 la s\u00e9quence de livraison pr\u00e9vue.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-32742deb auto-p elementor-widget elementor-widget-heading\" data-id=\"32742deb\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Examinez le bo\u00eetier IP55 du 5000INTL, son syst\u00e8me de refroidissement par liquide intelligent, son syst\u00e8me d'alerte pr\u00e9coce assist\u00e9 par IA et sa protection tridimensionnelle \u00e0 la lumi\u00e8re des \u00e9l\u00e9ments fournis. Int\u00e9grez les commandes de l'\u00e9quipement dans la strat\u00e9gie du site australien en mati\u00e8re d'espacement, de d\u00e9tection, d'isolement d'urgence, de drainage et d'intervention locale.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f3764bf7 auto-p elementor-widget elementor-widget-heading\" data-id=\"f3764bf7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Le port de Newcastle illustre l'ampleur logistique des projets en cours. Il est devenu le premier port de Nouvelle-Galles du Sud \u00e0 \u00eatre autoris\u00e9 \u00e0 stocker, dans son terminal, des syst\u00e8mes de batteries lithium-ion \u00e0 l'\u00e9chelle du r\u00e9seau, et avait d\u00e9j\u00e0 mis en place l'\u00e9quipement n\u00e9cessaire pour Tomago, Eraring et Bellambi Heights d'ici juillet 2026. \u00c0 lui seul, Tomago devrait utiliser plus de 400 unit\u00e9s de batteries. (<a href=\"https:\/\/www.energy-storage.news\/port-of-newcastle-cleared-to-safely-stage-grid-scale-battery-storage-systems-in-new-south-wales-australia\/\" target=\"_blank\" rel=\"noopener\">Installation du syst\u00e8me BESS au port de Newcastle<\/a>)<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b057e246 auto-p elementor-widget elementor-widget-heading\" data-id=\"b057e246\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Organisez le stockage temporaire, les autorisations routi\u00e8res et l'acc\u00e8s des grues en fonction des dimensions des conteneurs et des lots d'arriv\u00e9e. V\u00e9rifiez l'itin\u00e9raire avant de passer commande afin d'\u00e9viter que des probl\u00e8mes d'acc\u00e8s ne retardent le d\u00e9part des conteneurs pr\u00eats \u00e0 partir.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8b0a1f5d auto-p elementor-widget elementor-widget-heading\" data-id=\"8b0a1f5d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Les sites d'anciennes centrales \u00e9lectriques et les emplacements situ\u00e9s \u00e0 proximit\u00e9 des centres de charge peuvent offrir une infrastructure de raccordement pr\u00e9cieuse, mais ils comportent des r\u00e9seaux enterr\u00e9s, d'anciennes fondations, des acc\u00e8s restreints et des interfaces avec des installations sous tension. Utilisez les cotes MegSolid pour la premi\u00e8re esquisse, puis validez le nombre de blocs au cours des phases de planification des travaux de g\u00e9nie civil, des installations \u00e9lectriques et des mesures d'urgence.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-15110e78 auto-p elementor-widget elementor-widget-heading\" data-id=\"15110e78\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\"><strong>Zone de livraison en Australie<\/strong><\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c24566e0 elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"c24566e0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>Mod\u00e8les de connexion :<\/strong> MegSolid fournit les \u00e9quipements et les donn\u00e9es PCS pr\u00e9vus dans le contrat ; le demandeur australien du raccordement et son consultant int\u00e8grent le mod\u00e8le de la centrale, r\u00e9alisent les \u00e9tudes GPS et g\u00e8rent la proc\u00e9dure d'acceptation par le r\u00e9seau et l'AEMO.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>Garantie \u00e9nerg\u00e9tique :<\/strong> Le tableau sign\u00e9 doit pr\u00e9ciser s'il s'agit de l'\u00e9nergie en courant continu nominale, de l'\u00e9nergie en courant continu utile ou de l'\u00e9nergie en courant alternatif fournie au point d'injection ; le chiffre standard de 5,0159 MWh correspond \u00e0 l'\u00e9nergie nominale.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>Services du site :<\/strong> L'assistance est coordonn\u00e9e depuis les sites de MegSolid \u00e0 Hong Kong et \u00e0 Huzhou ; la pr\u00e9sence de personnel australien doit \u00eatre stipul\u00e9e dans le contrat et confi\u00e9e soit au service d'exp\u00e9dition de l'usine, soit \u00e0 un partenaire EPC local d\u00e9sign\u00e9.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>Bilan sur la chimie et les incendies :<\/strong> Consid\u00e9rer le mod\u00e8le 5000INTL comme un SHS180-314, 12P416S : batterie LFP hybride \u00e0 semi-conducteurs dot\u00e9e d\u2019un syst\u00e8me de refroidissement liquide intelligent et d\u2019une protection tridimensionnelle ; la strat\u00e9gie australienne de lutte contre les incendies doit s\u2019appuyer sur les donn\u00e9es fournies concernant les cellules et le syst\u00e8me, ainsi que sur la conception r\u00e9elle du site, et non sur une \u00e9tiquette LFP g\u00e9n\u00e9rique.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-aa78127b auto-h2 elementor-widget elementor-widget-heading\" data-id=\"aa78127b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Passer \u00e0 la conception d\u00e9taill\u00e9e de la configuration s\u00e9lectionn\u00e9e<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-86962207 auto-p elementor-widget elementor-widget-heading\" data-id=\"86962207\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Utilisez les m\u00eames hypoth\u00e8ses relatives aux \u00e9quipements ainsi que les m\u00eames valeurs de puissance et de consommation d\u2019\u00e9nergie des points d\u2019int\u00e9r\u00eat (POI) pour le dimensionnement des transformateurs, l\u2019\u00e9tude des raccordements et l\u2019am\u00e9nagement du site. Prenez ces d\u00e9cisions avant de passer \u00e0 la conception d\u00e9taill\u00e9e :<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6401b2b5 auto-table elementor-widget elementor-widget-text-editor\" data-id=\"6401b2b5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"cea-table-wrap\"><table><thead><tr><th>\u00c9tat d'avancement du projet<\/th><th>La voie \u00e0 suivre pour MegSolid<\/th><th>D\u00e9cision qui doit d\u00e9j\u00e0 \u00eatre prise<\/th><\/tr><\/thead><tbody><tr><td>Fonctionnement \u00e0 plusieurs m\u00e9gawatts pendant pr\u00e8s de deux heures<\/td><td>Blocs Standard 5000INTL<\/td><td>La marge \u00e9nerg\u00e9tique du POI couvre le niveau de charge utile (SOC), les pertes, les \u00e9quipements auxiliaires et l'ann\u00e9e contractuelle requise.<\/td><\/tr><tr><td>Prise de service de quatre ou huit heures<\/td><td>5 000 blocs \u00e9nerg\u00e9tiques INTL \u00e9valu\u00e9s selon un rapport batterie\/PCS sp\u00e9cifique au projet<\/td><td>La quantit\u00e9 de convertisseurs est calcul\u00e9e en fonction de la puissance des POI ; elle n'est pas d\u00e9riv\u00e9e du nombre de blocs d'\u00e9nergie.<\/td><\/tr><tr><td>Centrale de 500 kW raccord\u00e9e au r\u00e9seau de distribution<\/td><td>ESSC0500B-1075<\/td><td>Alimentation, transformateur, protection et r\u00e9gime de fonctionnement : 500 kW \/ 1,0752 MWh<\/td><\/tr><tr><td>Centrale de 1 MW raccord\u00e9e au r\u00e9seau de distribution<\/td><td>ESSC1000B-2150<\/td><td>Le trac\u00e9 du r\u00e9seau et le plan de mise en \u0153uvre correspondent \u00e0 1 MW \/ 2,1504 MWh<\/td><\/tr><tr><td>Alimentation PCS s\u00e9lectionn\u00e9e s\u00e9par\u00e9ment<\/td><td>MEGA0500TS ou un autre mod\u00e8le de la gamme MEGA TS<\/td><td>La tension continue, la puissance en kW, la puissance en kVA, le facteur de puissance r\u00e9actif et la charge du transformateur concordent<\/td><\/tr><tr><td>Obligation de soutien au r\u00e9seau<\/td><td>Bloc \u00e9nerg\u00e9tique s\u00e9lectionn\u00e9, ainsi qu'un PCS et un circuit de commande dont le fonctionnement a \u00e9t\u00e9 valid\u00e9 dans le mod\u00e8le de connexion<\/td><td>La r\u00e9ponse requise, les versions des mod\u00e8les et les justificatifs de mise en service sont d\u00e9finis<\/td><\/tr><tr><td>\u00c9nergie solaire ou \u00e9olienne partageant le point d'int\u00e9r\u00eat<\/td><td>Configuration \u00e0 couplage en courant alternatif ou en courant continu dans les limites d'une m\u00eame centrale<\/td><td>La source de recharge, la limitation de consommation, le comptage et la priorit\u00e9 du contr\u00f4leur sont fixes<\/td><\/tr><\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-97cac6fd auto-p elementor-widget elementor-widget-heading\" data-id=\"97cac6fd\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">D\u00e9finissez les points de raccordement entre les circuits d'alimentation solaire et ceux des batteries. Le <strong><a href=\"https:\/\/www.solidess.com\/fr\/ac-coupled-vs-dc-coupled-solar-battery-storage\/\" target=\"_blank\" style=\"color:#61ce70\">Comparaison entre les batteries \u00e0 couplage CA et \u00e0 couplage CC<\/a><\/strong> explique en quoi ce choix modifie les \u00e9quipements de conversion et le syst\u00e8me de contr\u00f4le. V\u00e9rifiez que la configuration choisie respecte le plafond d'exportation commun et le mod\u00e8le de raccordement approuv\u00e9.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-def06e2a auto-p elementor-widget elementor-widget-heading\" data-id=\"def06e2a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Utilisez les caract\u00e9ristiques techniques publi\u00e9es par MegSolid (5,0159 MWh \/ 2,7 MW) pour d\u00e9terminer le nombre initial de blocs et leur disposition. Le devis doit indiquer en quoi ce nombre r\u00e9pond aux exigences du POI, notamment en ce qui concerne la marge de livraison, l'affectation des PCS, le raccordement \u00e0 690 V CA, ainsi que les exigences en mati\u00e8re de refroidissement et de bo\u00eetier.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f159aa65 auto-p elementor-widget elementor-widget-heading\" data-id=\"f159aa65\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\"><strong>Forfait de donn\u00e9es e-mail minimum<\/strong><\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-54dadaef elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"54dadaef\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>Envoyer :<\/strong> \u00c9tat australien, puissance de charge\/d\u00e9charge (MW) du point d'int\u00e9r\u00eat (POI), \u00e9nergie fournie (MWh), dur\u00e9e, obligation en d\u00e9but ou en fin de vie, tension de raccordement, r\u00e9gime de fonctionnement et n\u00e9cessit\u00e9 ou non d'une r\u00e9ponse de stabilisation du r\u00e9seau.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>MegSolid fait son retour :<\/strong> un sch\u00e9ma pr\u00e9liminaire du produit, un nombre de blocs de 5 000 INTL ou une autre gamme PCS, les hypoth\u00e8ses de dimensionnement utilis\u00e9es et les \u00e9l\u00e9ments relatifs aux raccordements et au site qui restent propres \u00e0 chaque projet.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-bf43ab7d elementor-tablet-align-center elementor-align-center auto-cta elementor-widget elementor-widget-button\" data-id=\"bf43ab7d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"#elementor-action%3Aaction%3Dpopup%3Aopen%26settings%3DeyJpZCI6Ijk0OCIsInRvZ2dsZSI6ZmFsc2V9\" target=\"_blank\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Contactez MegSolid au sujet de votre projet BESS en Australie<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-d2752cc6 auto-faq e-flex e-con-boxed e-con e-child\" data-id=\"d2752cc6\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-146c7b31 elementor-widget elementor-widget-heading\" data-id=\"146c7b31\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">FAQ<\/h2>\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-90d60d6b e-con-full e-flex e-con e-child\" data-id=\"90d60d6b\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-238f5548 elementor-widget elementor-widget-n-accordion\" data-id=\"238f5548\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;default_state&quot;:&quot;all_collapsed&quot;,&quot;max_items_expended&quot;:&quot;one&quot;,&quot;n_accordion_animation_duration&quot;:{&quot;unit&quot;:&quot;ms&quot;,&quot;size&quot;:400,&quot;sizes&quot;:[]}}\" data-widget_type=\"nested-accordion.default\">\n\t\t\t\t\t\t\t<div class=\"e-n-accordion\" aria-label=\"Accord\u00e9on. Ouvrez les liens \u00e0 l&#039;aide de la touche Entr\u00e9e ou de la barre d&#039;espace, fermez-les avec la touche \u00c9chap et naviguez \u00e0 l&#039;aide des touches fl\u00e9ch\u00e9es.\">\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-5960\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"1\" tabindex=\"0\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-5960\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Combien d'unit\u00e9s 5000INTL faut-il pour une batterie de 10 MW \/ 20 MWh ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-5960\" class=\"elementor-element elementor-element-2bfa008f e-con-full e-flex e-con e-child\" data-id=\"2bfa008f\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-5960\" class=\"elementor-element elementor-element-b3964f8c e-con-full e-flex e-con e-child\" data-id=\"b3964f8c\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-1c2df086 elementor-widget elementor-widget-heading\" data-id=\"1c2df086\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Les quatre unit\u00e9s offrent une puissance nominale de 10,8 MW \/ 20,0636 MWh. Il ne reste donc que 63,6 kWh au-dessus de l'objectif \u00e9nerg\u00e9tique, avant de prendre en compte le SOC utilisable, les pertes de conversion, les \u00e9quipements auxiliaires et le vieillissement. V\u00e9rifiez la marge suppl\u00e9mentaire n\u00e9cessaire pour atteindre le POI.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-5961\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"2\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-5961\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Le mod\u00e8le 5000INTL standard est-il \u00e9quip\u00e9 d'une batterie d'une autonomie de quatre heures ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-5961\" class=\"elementor-element elementor-element-ba1a2d90 e-con-full e-flex e-con e-child\" data-id=\"ba1a2d90\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-5961\" class=\"elementor-element elementor-element-3eba801f e-con-full e-flex e-con e-child\" data-id=\"3eba801f\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-95da1f59 elementor-widget elementor-widget-heading\" data-id=\"95da1f59\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Avec une \u00e9nergie nominale de 5,0159 MWh et une puissance nominale en courant alternatif de 2,7 MW, son autonomie nominale est d'environ 1,86 heure. Pour les projets d'une dur\u00e9e de quatre heures, il convient d'adopter un rapport batterie\/PCS diff\u00e9rent, plut\u00f4t que d'ajouter simplement des blocs int\u00e9gr\u00e9s complets en se basant uniquement sur l'\u00e9nergie.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-5962\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"3\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-5962\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Que signifie le rendement maximal de 87,51 TP5T pour le mod\u00e8le 5000INTL en termes de dimensionnement ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-5962\" class=\"elementor-element elementor-element-0c1b249e e-con-full e-flex e-con e-child\" data-id=\"0c1b249e\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-5962\" class=\"elementor-element elementor-element-c264c476 e-con-full e-flex e-con e-child\" data-id=\"c264c476\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-e6de9dfe elementor-widget elementor-widget-heading\" data-id=\"e6de9dfe\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">N'utilisez la valeur 87,5% qu'aux limites de l'\u00e9quipement d\u00e9finies pour cette valeur. Le RTE du projet et l'\u00e9nergie POI fournie n\u00e9cessitent un mod\u00e8le de pertes complet couvrant le circuit de la batterie, le PCS, les transformateurs, le syst\u00e8me de collecteurs, les \u00e9quipements auxiliaires, le niveau de puissance et la temp\u00e9rature.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-5963\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"4\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-5963\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Quel produit MegSolid est compatible avec une batterie plus petite \u00e0 installer \u00e0 l'avant du compteur ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-5963\" class=\"elementor-element elementor-element-187efe93 e-con-full e-flex e-con e-child\" data-id=\"187efe93\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-5963\" class=\"elementor-element elementor-element-5fedc612 e-con-full e-flex e-con e-child\" data-id=\"5fedc612\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a5fd3aaf elementor-widget elementor-widget-heading\" data-id=\"a5fd3aaf\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Le mod\u00e8le ESSC0500B-1075 offre une puissance de 500 kW \/ 1,0752 MWh, tandis que le mod\u00e8le ESSC1000B-2150 offre une puissance de 1 MW \/ 2,1504 MWh. Le choix entre ces deux mod\u00e8les d\u00e9pend de la capacit\u00e9 des lignes d'alimentation, de la configuration des transformateurs, de la taille du bloc de maintenance et des projets d'extension pr\u00e9vus.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-5964\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"5\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-5964\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Le dimensionnement d'un syst\u00e8me de stockage d'\u00e9nergie par batterie (BESS) australien doit-il se faire en MWh \u00ab conteneur \u00bb ou en MWh \u00ab POI \u00bb ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-5964\" class=\"elementor-element elementor-element-ce7228a3 e-con-full e-flex e-con e-child\" data-id=\"ce7228a3\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-5964\" class=\"elementor-element elementor-element-8a6a3850 e-con-full e-flex e-con e-child\" data-id=\"8a6a3850\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-b44c89ef elementor-widget elementor-widget-heading\" data-id=\"b44c89ef\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Partons de la quantit\u00e9 d'\u00e9nergie (en MWh) requise au niveau du compteur du point d'injection (POI) pr\u00e9vu dans le contrat. La puissance nominale indiqu\u00e9e sur la plaque signal\u00e9tique du conteneur est une valeur de conception en amont ; le niveau de charge utile (SOC), la capacit\u00e9 r\u00e9siduelle, les pertes et les \u00e9quipements auxiliaires d\u00e9terminent la quantit\u00e9 d'\u00e9nergie qui parvient effectivement au r\u00e9seau.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-5965\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"6\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-5965\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Dans quels cas faut-il choisir s\u00e9par\u00e9ment la capacit\u00e9 de la batterie et la puissance du PCS ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-5965\" class=\"elementor-element elementor-element-641057ff e-con-full e-flex e-con e-child\" data-id=\"641057ff\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-5965\" class=\"elementor-element elementor-element-585c5a6c e-con-full e-flex e-con e-child\" data-id=\"585c5a6c\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-83e7e5cd elementor-widget elementor-widget-heading\" data-id=\"83e7e5cd\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Il convient de prendre des d\u00e9cisions distinctes lorsque la dur\u00e9e de livraison requise diff\u00e8re du rapport de blocage standard, lorsque les puissances d'absorption et de restitution sont asym\u00e9triques, ou lorsque la charge r\u00e9active modifie la puissance PCS requise en kVA.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-5966\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"7\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-5966\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Toutes les batteries \u00e0 l'\u00e9chelle du r\u00e9seau en Australie ont-elles besoin d'un syst\u00e8me de contr\u00f4le de puissance (PCS) permettant de former le r\u00e9seau ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-5966\" class=\"elementor-element elementor-element-391531a2 e-con-full e-flex e-con e-child\" data-id=\"391531a2\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-5966\" class=\"elementor-element elementor-element-7bc378ad e-con-full e-flex e-con e-child\" data-id=\"7bc378ad\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-8db75309 elementor-widget elementor-widget-heading\" data-id=\"8db75309\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Non. Les exigences en mati\u00e8re de contr\u00f4le sont d\u00e9termin\u00e9es par l'emplacement du r\u00e9seau, les conditions de puissance du syst\u00e8me, les \u00e9tudes de raccordement et les services sous-trait\u00e9s. Dans le cadre des projets de formation de r\u00e9seau, il convient de valider le mod\u00e8le PCS, le contr\u00f4leur de la centrale et le chemin de validation avant la validation de la conception du raccordement.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-5967\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"8\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-5967\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Une batterie \u00e0 l'\u00e9chelle du r\u00e9seau peut-elle partager un point d'int\u00e9r\u00eat (POI) avec un parc solaire ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-5967\" class=\"elementor-element elementor-element-64c901cc e-con-full e-flex e-con e-child\" data-id=\"64c901cc\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-5967\" class=\"elementor-element elementor-element-c8512e49 e-con-full e-flex e-con e-child\" data-id=\"c8512e49\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-30bd0be3 elementor-widget elementor-widget-heading\" data-id=\"30bd0be3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Oui, lorsque le contr\u00f4leur g\u00e8re la production solaire, la charge et la d\u00e9charge des batteries, la limitation de la production et la limite d'exportation partag\u00e9e. Le couplage CA ou CC modifie le point de rencontre des circuits d'alimentation, mais ne supprime pas le plafond du POI.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-5968\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"9\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-5968\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Pourquoi le transformateur principal peut-il limiter un syst\u00e8me de stockage d'\u00e9nergie par batterie (BESS) fonctionnant \u00e0 pleine capacit\u00e9 ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-5968\" class=\"elementor-element elementor-element-490272b6 e-con-full e-flex e-con e-child\" data-id=\"490272b6\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-5968\" class=\"elementor-element elementor-element-4ef12a26 e-con-full e-flex e-con e-child\" data-id=\"4ef12a26\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-7ba94480 elementor-widget elementor-widget-heading\" data-id=\"7ba94480\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Les blocs de batteries peuvent \u00eatre pr\u00eats alors m\u00eame que la capacit\u00e9 MVA du transformateur, la temp\u00e9rature, la demande r\u00e9active ou une coupure de courant limitent la puissance en MW inject\u00e9e dans le r\u00e9seau. La puissance nominale et la redondance du transformateur doivent permettre d'atteindre les m\u00eames points de fonctionnement que ceux garantis dans le POI.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-5969\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"10\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-5969\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Comment le 5000INTL facilite-t-il l'exploitation du site australien ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-5969\" class=\"elementor-element elementor-element-b5db596e e-con-full e-flex e-con e-child\" data-id=\"b5db596e\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-5969\" class=\"elementor-element elementor-element-bfeac95f e-con-full e-flex e-con e-child\" data-id=\"bfeac95f\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-cdef5248 elementor-widget elementor-widget-heading\" data-id=\"cdef5248\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">L'unit\u00e9 associe un syst\u00e8me de refroidissement par liquide intelligent, un bo\u00eetier conforme \u00e0 la norme IP55, un syst\u00e8me d'alerte pr\u00e9coce assist\u00e9 par IA et une protection tridimensionnelle, le tout au sein d'un bloc d'une puissance nominale de 5,0159 MWh \/ 2,7 MW. L'installation est compl\u00e9t\u00e9e par des voies d'acc\u00e8s pour les pompiers, un syst\u00e8me de drainage, un dispositif d'isolation d'urgence et un plan d'intervention au niveau du site.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-59610\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"11\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-59610\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Quels changements pour une batterie \u00e0 l'\u00e9chelle du r\u00e9seau dans le cadre du NEM ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-59610\" class=\"elementor-element elementor-element-14e94ee3 e-con-full e-flex e-con e-child\" data-id=\"14e94ee3\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-59610\" class=\"elementor-element elementor-element-c71d04da e-con-full e-flex e-con e-child\" data-id=\"c71d04da\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-06094b67 elementor-widget elementor-widget-heading\" data-id=\"06094b67\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Les projets NEM coordonnent les op\u00e9rations d'enregistrement, de r\u00e9partition, de comptage et de raccordement par l'interm\u00e9diaire de l'AEMO et du gestionnaire de r\u00e9seau concern\u00e9. Les limites des points d'int\u00e9r\u00eat (POI), les donn\u00e9es GPS, les ensembles de mod\u00e8les et les r\u00e9sultats de la mise en service sont pris en compte dans le choix des \u00e9quipements.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-59611\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"12\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-59611\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Quels sont les changements concernant les batteries install\u00e9es en amont du compteur en Australie-Occidentale ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-59611\" class=\"elementor-element elementor-element-bfa149a0 e-con-full e-flex e-con e-child\" data-id=\"bfa149a0\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-59611\" class=\"elementor-element elementor-element-a0baa534 e-con-full e-flex e-con e-child\" data-id=\"a0baa534\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-5d51cb42 elementor-widget elementor-widget-heading\" data-id=\"5d51cb42\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">La participation au WEM et le fonctionnement du r\u00e9seau local d\u00e9terminent les besoins en mati\u00e8re de recettes, de r\u00e9partition et de raccordement. Les cr\u00e9dits de capacit\u00e9 peuvent avoir une incidence sur le mod\u00e8le commercial, tandis que le dimensionnement des \u00e9quipements doit respecter la courbe d'exploitation r\u00e9elle du projet et les limites du r\u00e9seau.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-59612\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"13\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-59612\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Que r\u00e9v\u00e8lent aux acheteurs les projets li\u00e9s aux batteries men\u00e9s dans le Queensland et en Nouvelle-Galles du Sud ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-59612\" class=\"elementor-element elementor-element-d5de049a e-con-full e-flex e-con e-child\" data-id=\"d5de049a\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-59612\" class=\"elementor-element elementor-element-912dda44 e-con-full e-flex e-con e-child\" data-id=\"912dda44\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-f2f1a1da elementor-widget elementor-widget-heading\" data-id=\"f2f1a1da\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Le \u00ab Supernode \u00bb du Queensland met en avant les rapports puissance\/\u00e9nergie sur longue dur\u00e9e et l\u2019int\u00e9gration dans la formation du r\u00e9seau. Des projets en Nouvelle-Galles du Sud, tels que Limondale et Waratah, montrent comment la puissance asym\u00e9trique, la disponibilit\u00e9 des transformateurs et le cheminement POI peuvent influencer les performances r\u00e9elles.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>\u00c9valuez les capacit\u00e9s de stockage par batterie \u00e0 l'\u00e9chelle du r\u00e9seau australien en fonction de la puissance nominale (POI) en MW, de l'\u00e9nergie fournie en MWh et de la dur\u00e9e de fonctionnement. Comparez le MegSolid 5000INTL, les syst\u00e8mes ESSC, la r\u00e9partition des PCS, les pertes au niveau des transformateurs et les frais de raccordement avant de proc\u00e9der \u00e0 l'achat.<\/p>","protected":false},"author":4,"featured_media":5265,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"_joinchat":[],"footnotes":""},"categories":[27,1],"tags":[577,575,581,579,578,582,460,576,580,574],"class_list":["post-5268","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-news","category-bess","tag-5000intl","tag-australian-bess","tag-battery-pcs-sizing","tag-battery-storage-mw-mwh","tag-bess-poi","tag-bess-transformer","tag-four-hour-battery-storage","tag-front-of-meter-battery-storage","tag-grid-forming-bess","tag-grid-scale-battery-storage-australia"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/posts\/5268","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/comments?post=5268"}],"version-history":[{"count":1,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/posts\/5268\/revisions"}],"predecessor-version":[{"id":5269,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/posts\/5268\/revisions\/5269"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/media\/5265"}],"wp:attachment":[{"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/media?parent=5268"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/categories?post=5268"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/tags?post=5268"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}