{"id":5524,"date":"2026-09-24T09:06:44","date_gmt":"2026-09-24T01:06:44","guid":{"rendered":"https:\/\/www.solidess.com\/?p=5524"},"modified":"2026-09-24T18:19:28","modified_gmt":"2026-09-24T10:19:28","slug":"stockage-par-batterie-dans-les-caves-espagnoles-essa100","status":"publish","type":"post","link":"https:\/\/www.solidess.com\/fr\/battery-storage-spanish-wineries-essa100\/","title":{"rendered":"Stockage par batterie pour les caves espagnoles : installation du MegSolid ESSA100 pour faire face aux pics d'activit\u00e9 li\u00e9s aux vendanges"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"5524\" class=\"elementor elementor-5524\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-bf4793c e-con-full auto-article-root e-flex e-con e-parent\" data-id=\"bf4793c\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-6172f261 auto-image elementor-widget elementor-widget-image\" data-id=\"6172f261\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"1254\" height=\"1254\" src=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Battery-Storage-for-Spanish-Wineries-Cover.jpg\" class=\"attachment-1536x1536 size-1536x1536 wp-image-5521\" alt=\"Syst\u00e8me de stockage par batterie MegSolid ESSA0100B-0215 install\u00e9 dans un domaine viticole espagnol \u00e9quip\u00e9 d\u2019une installation solaire sur toiture, affichant une injection mesur\u00e9e sur site de 245 kW, un objectif d\u2019injection de 170 kW, un besoin en batterie de 75 kW et une capacit\u00e9 nominale de 215,04 kWh.\" srcset=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Battery-Storage-for-Spanish-Wineries-Cover.jpg 1254w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Battery-Storage-for-Spanish-Wineries-Cover-300x300.jpg 300w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Battery-Storage-for-Spanish-Wineries-Cover-1024x1024.jpg 1024w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Battery-Storage-for-Spanish-Wineries-Cover-150x150.jpg 150w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Battery-Storage-for-Spanish-Wineries-Cover-768x768.jpg 768w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Battery-Storage-for-Spanish-Wineries-Cover-12x12.jpg 12w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Battery-Storage-for-Spanish-Wineries-Cover-600x600.jpg 600w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Battery-Storage-for-Spanish-Wineries-Cover-100x100.jpg 100w\" sizes=\"(max-width: 1254px) 100vw, 1254px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f3bd10d7 auto-p elementor-widget elementor-widget-heading\" data-id=\"f3bd10d7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Les caves espagnoles confront\u00e9es \u00e0 un d\u00e9ficit d'importation de 75 kW et \u00e0 une obligation de d\u00e9charge quotidienne de 136,25 kWh en courant alternatif devraient utiliser le <strong><a href=\"https:\/\/www.solidess.com\/fr\/product\/systeme-de-stockage-denergie-en-armoire-exterieure\/\" target=\"_blank\" style=\"color:#61ce70\">MegSolid ESSA0100B-0215<\/a><\/strong> pour le sc\u00e9nario d'exploitation d\u00e9fini \u00ab r\u00e9colte et \u00e9nergie solaire \u00bb. Sa puissance nominale en courant alternatif de 100 kW et son \u00e9nergie nominale de 215,04 kWh d\u00e9passent les deux limites fix\u00e9es pour cette application, contrairement \u00e0 l'armoire de 50 kW \/ 100,352 kWh.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d372581b auto-p elementor-widget elementor-widget-heading\" data-id=\"d372581b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">La batterie doit couvrir le d\u00e9ficit d'importation mesur\u00e9 et l'ensemble de la plage de fonctionnement ; la puissance en kWp du parc photovolta\u00efque ne d\u00e9termine pas la capacit\u00e9 nominale du syst\u00e8me de stockage d'\u00e9nergie (BESS). Le mod\u00e8le ESSA0100B-0215 combine cette puissance et cette \u00e9nergie avec un syst\u00e8me de gestion de l'\u00e9nergie (EMS) int\u00e9gr\u00e9, un transformateur d'isolement int\u00e9gr\u00e9 et une interface 400 V. Le <strong><a href=\"https:\/\/www.solidess.com\/fr\/controle-de-lecretement-des-pics-de-charge-de-la-batterie-pcc\/\" target=\"_blank\" style=\"color:#61ce70\">Contr\u00f4le de lissage des pics de la PCC<\/a><\/strong> et <strong><a href=\"https:\/\/www.solidess.com\/fr\/stockage-denergie-solaire-par-batterie-a-couplage-en-courant-alternatif-vs-couplage-en-courant-continu\/\" target=\"_blank\" style=\"color:#61ce70\">R\u00e9novation d'une installation solaire \u00e0 couplage CA<\/a><\/strong> puis raccordez l'armoire au syst\u00e8me de cave \u00e0 vin existant.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-df7d52b3 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"df7d52b3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">ESSA0100B-0215 Couvre les besoins de la cave en \u00e9lectricit\u00e9 (75 kW \/ 136,25 kWh)<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-db249797 auto-p elementor-widget elementor-widget-heading\" data-id=\"db249797\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">La demande de traitement atteint <strong>245 kW<\/strong> face \u00e0 un <strong>170 kW<\/strong> importer la cible, en cr\u00e9ant un <strong>75 kW<\/strong> Caract\u00e9ristiques de la batterie :<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1883a313 auto-p elementor-widget elementor-widget-heading\" data-id=\"1883a313\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\"><code>Puissance requise du syst\u00e8me de stockage d'\u00e9nergie par batterie (BESS) = 245 kW d'importation du site \u2212 170 kW d'objectif d'importation = 75 kW<\/code><\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ef953c44 auto-p elementor-widget elementor-widget-heading\" data-id=\"ef953c44\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Fournitures ESSA0100B-0215 <strong>Puissance nominale en courant alternatif de 100 kW<\/strong>, ce qui laisse <strong>25 kW de marge de puissance nominale<\/strong> sup\u00e9rieur au d\u00e9ficit mesur\u00e9 avant la r\u00e9duction de la puissance du site et les limites d'exploitation. Son <strong>Capacit\u00e9 nominale de la batterie : 215,04 kWh<\/strong> cela permet \u00e9galement au projet d'atteindre une classe \u00e9nerg\u00e9tique nominale suffisante pour tester l'ensemble du cycle \u00ab production + fonctionnement en soir\u00e9e \u00bb.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b2e5923c auto-p elementor-widget elementor-widget-heading\" data-id=\"b2e5923c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">L'armoire ESSA regroupe la batterie, l'\u00e9tage de conversion de puissance, le transformateur d'isolement int\u00e9gr\u00e9 et les fonctions EMS au sein d'une seule plateforme ext\u00e9rieure. L'acheteur b\u00e9n\u00e9ficie d'une solution d\u00e9finie <strong>400 V<\/strong>, <strong>144 A<\/strong>, <strong>IP54<\/strong> une solution int\u00e9gr\u00e9e avec des communications RS485 et TCP\/IP, plut\u00f4t que des fonctions de stockage centrales distinctes ne r\u00e9pondant \u00e0 aucune sp\u00e9cification d'armoire unique.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-189fdcce auto-table elementor-widget elementor-widget-text-editor\" data-id=\"189fdcce\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"cea-table-wrap\"><table><thead><tr><th>Conditions d'achat<\/th><th>Droit d'accise sur les vins<\/th><th>R\u00e9sultat ESSA0100B-0215<\/th><\/tr><\/thead><tbody><tr><td>R\u00e9duction des pics d'importation<\/td><td>75 kW<\/td><td>Puissance nominale en courant alternatif : 100 kW ; marge nominale : 25 kW<\/td><\/tr><tr><td>Exploiter pleinement l'\u00e9nergie de la r\u00e9colte<\/td><td>75 kW pendant 45 min = 56,25 kWh (courant alternatif)<\/td><td>Inclus dans le test \u00e9nerg\u00e9tique<\/td><\/tr><tr><td>Production en soir\u00e9e<\/td><td>80 kWh CA<\/td><td>La consommation totale atteint 136,25 kWh en courant alternatif<\/td><\/tr><tr><td>Capacit\u00e9 nominale de la batterie<\/td><td>Il faut plus de 136,25 kWh en courant alternatif avant de tenir compte des pertes et de la r\u00e9serve de SOC.<\/td><td>Classe \u00e9nerg\u00e9tique nominale : 215,04 kWh<\/td><\/tr><\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-142c3ad8 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"142c3ad8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">L'armoire de 50 kW ne permet pas de r\u00e9pondre aux exigences d\u00e9finies<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-113ebfd3 auto-image elementor-widget elementor-widget-image\" data-id=\"113ebfd3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"1448\" height=\"1086\" src=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Spanish-Winery-ESSA0100B-0215-vs-ESSA0050B-0100-Decision.jpg\" class=\"attachment-1536x1536 size-1536x1536 wp-image-5522\" alt=\"Comparaison MegSolid entre les mod\u00e8les ESSA0100B-0215 et ESSA0050B-0100 pour une cave \u00e0 vin espagnole n\u00e9cessitant une r\u00e9duction de la puissance de pointe de 75 kW et une consommation en courant alternatif de 136,25 kWh\" srcset=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Spanish-Winery-ESSA0100B-0215-vs-ESSA0050B-0100-Decision.jpg 1448w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Spanish-Winery-ESSA0100B-0215-vs-ESSA0050B-0100-Decision-300x225.jpg 300w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Spanish-Winery-ESSA0100B-0215-vs-ESSA0050B-0100-Decision-1024x768.jpg 1024w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Spanish-Winery-ESSA0100B-0215-vs-ESSA0050B-0100-Decision-768x576.jpg 768w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Spanish-Winery-ESSA0100B-0215-vs-ESSA0050B-0100-Decision-16x12.jpg 16w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Spanish-Winery-ESSA0100B-0215-vs-ESSA0050B-0100-Decision-600x450.jpg 600w\" sizes=\"(max-width: 1448px) 100vw, 1448px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-66694d65 auto-p elementor-widget elementor-widget-heading\" data-id=\"66694d65\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Le mod\u00e8le ESSA0050B-0100 est un produit MegSolid performant destin\u00e9 aux petits domaines viticoles, mais il s'av\u00e8re ici sous-dimensionn\u00e9 pour deux raisons distinctes.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0bb4cb92 auto-p elementor-widget elementor-widget-heading\" data-id=\"0bb4cb92\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Son <strong>Puissance nominale en courant alternatif de 50 kW<\/strong> ne peut pas livrer le <strong>75 kW<\/strong> r\u00e9duction. M\u00eame \u00e0 la puissance nominale, l'injection dans le r\u00e9seau reste \u00e0 <strong>195 kW<\/strong>, c'est-\u00e0-dire <strong>25 kW et plus<\/strong> l'objectif de 170 kW :<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b481f25f auto-p elementor-widget elementor-widget-heading\" data-id=\"b481f25f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\"><code>Importation du site : 245 kW \u2212 Production du BESS : 50 kW = Importation r\u00e9siduelle : 195 kW<\/code><\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6fc1f77c auto-p elementor-widget elementor-widget-heading\" data-id=\"6fc1f77c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Son <strong>Capacit\u00e9 nominale de la batterie : 100,352 kWh<\/strong> est \u00e9galement <strong>35 898 kWh de moins<\/strong> les \u00e9l\u00e9ments requis <strong>136,25 kWh CA<\/strong> s\u00e9quence avant que les pertes li\u00e9es \u00e0 la conversion, la consommation auxiliaire ou une r\u00e9serve SOC de fonctionnement ne soient prises en compte. Aucun r\u00e9glage du syst\u00e8me de gestion de l'\u00e9nergie (EMS) ne peut pallier un d\u00e9ficit physique de puissance PCS ou d'\u00e9nergie stock\u00e9e.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c3b0598f auto-p elementor-widget elementor-widget-heading\" data-id=\"c3b0598f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Le <strong><a href=\"https:\/\/www.solidess.com\/fr\/comment-specifier-un-systeme-de-stockage-par-batterie-ci-de-50-kw-100-kwh\/\" target=\"_blank\" style=\"color:#61ce70\">Cat\u00e9gorie d'armoire de 50 kW \/ 100 kWh<\/a><\/strong> le parcours MegSolid reste le bon choix lorsque le d\u00e9ficit mesur\u00e9 reste inf\u00e9rieur \u00e0 50 kW et que l'\u00e9nergie CA utilisable v\u00e9rifi\u00e9e couvre l'int\u00e9gralit\u00e9 de l'\u00e9v\u00e9nement. \u00c0 <strong>75 kW et 136,25 kWh en courant alternatif<\/strong>, le mod\u00e8le ESSA0100B-0215 est parfaitement adapt\u00e9 \u00e0 l'application pr\u00e9vue.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-018003df auto-h2 elementor-widget elementor-widget-heading\" data-id=\"018003df\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">La fen\u00eatre de d\u00e9charge compl\u00e8te d\u00e9montre l'avantage de 215,04 kWh<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3c69982a auto-image elementor-widget elementor-widget-image\" data-id=\"3c69982a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"1448\" height=\"1086\" src=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Spanish-Winery-Solar-Zero-Export-Engineering-Proof.jpg\" class=\"attachment-1536x1536 size-1536x1536 wp-image-5523\" alt=\"Infographie sur l&#039;ing\u00e9nierie d&#039;une cave espagnole indiquant une puissance de pointe de 75 kW pendant les vendanges, une consommation totale en courant alternatif de 136,25 kWh, la recharge \u00e0 partir de l&#039;exc\u00e9dent photovolta\u00efque, la priorit\u00e9 \u00ab z\u00e9ro exportation \u00bb vers le r\u00e9seau public (PCC) et les v\u00e9rifications de mise en service\" srcset=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Spanish-Winery-Solar-Zero-Export-Engineering-Proof.jpg 1448w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Spanish-Winery-Solar-Zero-Export-Engineering-Proof-300x225.jpg 300w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Spanish-Winery-Solar-Zero-Export-Engineering-Proof-1024x768.jpg 1024w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Spanish-Winery-Solar-Zero-Export-Engineering-Proof-768x576.jpg 768w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Spanish-Winery-Solar-Zero-Export-Engineering-Proof-16x12.jpg 16w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Spanish-Winery-Solar-Zero-Export-Engineering-Proof-600x450.jpg 600w\" sizes=\"(max-width: 1448px) 100vw, 1448px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7673c2ca auto-p elementor-widget elementor-widget-heading\" data-id=\"7673c2ca\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Le d\u00e9ficit de 75 kW de la cave dure pendant trois intervalles de 15 minutes. Cet intervalle de lissage des pics n\u00e9cessite <strong>56,25 kWh CA<\/strong>. Le pompage, le refroidissement et le traitement en soir\u00e9e n\u00e9cessitent ensuite une autre <strong>80 kWh CA<\/strong>, ce qui donne la s\u00e9quence mesur\u00e9e suivante : <strong>136,25 kWh CA<\/strong>.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-67e4da9a auto-p elementor-widget elementor-widget-heading\" data-id=\"67e4da9a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\"><code>Pointe de production : 75 kW \u00d7 0,75 h = 56,25 kWh CA<br>Service du soir : 80 kWh en courant alternatif<br>Consommation totale en d\u00e9charge : 56,25 + 80 = 136,25 kWh CA<\/code><\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3827caee auto-h3 elementor-widget elementor-widget-heading\" data-id=\"3827caee\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Distinguer la puissance nominale de la puissance active fournie v\u00e9rifi\u00e9e<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8e0e99b6 auto-p elementor-widget elementor-widget-heading\" data-id=\"8e0e99b6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Le mod\u00e8le ESSA0100B-0215 dispose de <strong>114,688 kWh d'\u00e9nergie nominale suppl\u00e9mentaire de la batterie<\/strong> que l'ESSA0050B-0100. Par rapport \u00e0 la puissance nominale de 136,25 kWh en courant alternatif, sa puissance nominale de 215,04 kWh entra\u00eene une <strong>Enveloppe \u00e9nerg\u00e9tique nominale de 78,79 kWh<\/strong> en ce qui concerne les pertes de conversion, le seuil minimal convenu pour le niveau de charge (SOC) et la marge d'exploitation. La diff\u00e9rence de 78,79 kWh ne correspond pas automatiquement \u00e0 de l'\u00e9nergie CA disponible ; la mise en service doit permettre de v\u00e9rifier la production CA utilisable dans les limites convenues en termes de puissance, de temp\u00e9rature et de niveau de charge (SOC).<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3b986ede auto-p elementor-widget elementor-widget-heading\" data-id=\"3b986ede\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Le mod\u00e8le ESSA0100B-0215 peut \u00eatre mis en service apr\u00e8s une s\u00e9quence de production compl\u00e8te ; le mod\u00e8le ESSA0050B-0100 \u00e9choue aux tests de puissance et d'\u00e9nergie avant m\u00eame les essais sur site. Cela \u00e9vite d'acheter une armoire qui r\u00e9duit la pointe de consommation sans atteindre l'objectif fix\u00e9 et qui se vide avant la fin de la production du soir.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7357fc59 elementor-tablet-align-center elementor-align-center auto-cta elementor-widget elementor-widget-button\" data-id=\"7357fc59\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"#elementor-action%3Aaction%3Dpopup%3Aopen%26settings%3DeyJpZCI6Ijk0OCIsInRvZ2dsZSI6ZmFsc2V9\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Valider le test d'\u00e9nergie utile ESSA0100B-0215 pour le fonctionnement en courant alternatif de 136,25 kWh de la cave \u00e0 vin<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-94cfe13f auto-h2 elementor-widget elementor-widget-heading\" data-id=\"94cfe13f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Utilisez le m\u00eame bo\u00eetier ESSA100 pour les pics de production et le d\u00e9calage solaire<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-26d4eb58 auto-p elementor-widget elementor-widget-heading\" data-id=\"26d4eb58\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">La demande li\u00e9e aux vendanges et l'exc\u00e9dent solaire hors p\u00e9riode de vendanges g\u00e9n\u00e8rent des utilisations diff\u00e9rentes pour le m\u00eame syst\u00e8me de stockage. Pendant la transformation du raisin, l'\u00e9cr\u00eatement des pics de consommation permet de respecter l'objectif d'importation. En dehors de la p\u00e9riode des vendanges, la batterie stocke l'exc\u00e9dent photovolta\u00efque exploitable de midi et le restitue lorsque la cave en a besoin plus tard dans la journ\u00e9e.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7cc0b0f3 auto-p elementor-widget elementor-widget-heading\" data-id=\"7cc0b0f3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">La puissance nominale des panneaux photovolta\u00efques ne d\u00e9termine pas \u00e0 elle seule la taille de la batterie. L'\u00e9nergie de charge pertinente correspond \u00e0 l'exc\u00e9dent, intervalle par intervalle, apr\u00e8s prise en compte de la charge de la cave :<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6fb79c37 auto-p elementor-widget elementor-widget-heading\" data-id=\"6fb79c37\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\"><code>Exc\u00e9dent photovolta\u00efque disponible = \u03a3 max(production photovolta\u00efque \u2212 charge simultan\u00e9e du site, 0) \u00d7 dur\u00e9e de l'intervalle<\/code><\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-62285144 auto-h3 elementor-widget elementor-widget-heading\" data-id=\"62285144\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Calculer la charge solaire \u00e0 partir de l'exc\u00e9dent mesur\u00e9<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-77b37eca auto-p elementor-widget elementor-widget-heading\" data-id=\"77b37eca\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Avec une production photovolta\u00efque de 78 kW et une charge du site de 33 kW, <strong>45 kW<\/strong> est disponible \u00e0 la limite de l'AC. Deux intervalles de 30 minutes permettent de <strong>45 kWh CA<\/strong> avant la conversion et les contraintes d'exploitation. Le <strong><a href=\"https:\/\/www.solidess.com\/fr\/pv-charging-priority-ci-bess\/\" target=\"_blank\" style=\"color:#61ce70\">Priorit\u00e9 de recharge photovolta\u00efque<\/a><\/strong> Il faut r\u00e9server de l'espace dans le SOC avant que cet exc\u00e9dent n'arrive ; recharger la batterie \u00e0 partir du r\u00e9seau trop t\u00f4t emp\u00eacherait la captation de l'\u00e9nergie solaire.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e6ce1b15 auto-p elementor-widget elementor-widget-heading\" data-id=\"e6ce1b15\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Les fonctions EMS int\u00e9gr\u00e9es de MegSolid, ainsi que la pr\u00e9vision de la capacit\u00e9 des batteries et de la dur\u00e9e de d\u00e9charge, offrent \u00e0 l\u2019EPC une plateforme produit adapt\u00e9e \u00e0 ces deux fonctions. L\u2019acc\u00e8s simultan\u00e9 \u00e0 la charge, aux batteries, au r\u00e9seau, au g\u00e9n\u00e9rateur diesel et au syst\u00e8me photovolta\u00efque permet \u00e9galement de prendre en charge une architecture \u00e9nerg\u00e9tique plus \u00e9tendue pour la cave. En dehors de la p\u00e9riode des vendanges, l\u2019\u00e9nergie photovolta\u00efque disponible en milieu de journ\u00e9e peut \u00eatre stock\u00e9e pour r\u00e9pondre aux besoins ult\u00e9rieurs de la cave.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-45c3523a auto-h2 elementor-widget elementor-widget-heading\" data-id=\"45c3523a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Un projet viticole espagnol pr\u00e9sente le m\u00eame sch\u00e9ma de lissage des pics de consommation<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e8f954dd auto-p elementor-widget elementor-widget-heading\" data-id=\"e8f954dd\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Le projet \u00ab Bodega Vega Tolosa \u00bb \u00e0 Albacete, pr\u00e9sent\u00e9 par CEGASA, allie <strong>100 kWc de panneaux photovolta\u00efques<\/strong>, <strong>187,6 kWh de capacit\u00e9 de stockage<\/strong>, l'\u00e9cr\u00eatement des pics et l'injection nulle. Le rapport du projet indique que <strong>19 800 \u20ac par an d'\u00e9conomies sur les d\u00e9penses \u00e9nerg\u00e9tiques<\/strong> et <strong>10,2 tonnes d'\u00e9conomies de CO\u2082<\/strong> pour cette installation. Consultez le <a href=\"https:\/\/www.cegasa.com\/en\/success-stories\/peak-shaving-installation-at-bodega-vega-tolosa\" target=\"_blank\" rel=\"noopener\">Fiche du projet \u00ab Bodega Vega Tolosa \u00bb<\/a>.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e2f9a4d0 auto-p elementor-widget elementor-widget-heading\" data-id=\"e2f9a4d0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Les documents publi\u00e9s relatent le stockage, l\u2019autoconsommation, la gestion des pics de consommation et la gestion des exportations dans un domaine viticole espagnol. Ils ne d\u00e9terminent pas la notation d\u2019un autre site. L\u2019avantage de MegSolid r\u00e9side dans le fait que la gamme ESSA permet de convertir la charge mesur\u00e9e du nouveau domaine viticole en une d\u00e9cision directe concernant l\u2019armoire : <strong>50 kW \/ 100 352 kWh<\/strong> pour la plus petite des deux limites ou <strong>100 kW \/ 215,04 kWh<\/strong> pour la charge en courant alternatif de 75 kW et 136,25 kWh \u00e9valu\u00e9e ici.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-62537568 auto-h3 elementor-widget elementor-widget-heading\" data-id=\"62537568\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Veiller \u00e0 bien distinguer les \u00e9conomies r\u00e9alis\u00e9es gr\u00e2ce au projet d\u00e9j\u00e0 publi\u00e9 de celles li\u00e9es \u00e0 la nouvelle cave<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e6068836 auto-p elementor-widget elementor-widget-heading\" data-id=\"e6068836\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Tout calcul commercial d\u00e9pend toujours du tarif propre \u00e0 la cave, des co\u00fbts d'importation \u00e9vit\u00e9s, de la valeur \u00e0 l'exportation, du m\u00e9canisme de tarification en heures de pointe et du calendrier d'exploitation. La recommandation relative au produit ne repose pas sur la reproduction des \u00e9conomies r\u00e9alis\u00e9es par un autre projet ; elle d\u00e9pend de la capacit\u00e9 de l'ESSA100 \u00e0 franchir les deux limites techniques mesur\u00e9es.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-aea4e692 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"aea4e692\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Les options \u00ab Zero Export \u00bb, \u00ab EMS Priority \u00bb et \u00ab Meter Direction \u00bb doivent fonctionner comme un seul et m\u00eame syst\u00e8me<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-492609a3 auto-p elementor-widget elementor-widget-heading\" data-id=\"492609a3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">L'Espagne <a href=\"https:\/\/www.boe.es\/buscar\/act.php?id=BOE-A-2019-5089\" target=\"_blank\" rel=\"noopener\">D\u00e9cret royal n\u00b0 244\/2019<\/a> d\u00e9finit l\u2019\u00ab autoconsommation sans exc\u00e9dents \u00bb comme une autoconsommation dot\u00e9e d\u2019un m\u00e9canisme emp\u00eachant l\u2019\u00e9nergie exc\u00e9dentaire d\u2019\u00eatre inject\u00e9e dans le r\u00e9seau. L\u2019ITC-BT-40 modifi\u00e9e, en vertu de la <a href=\"https:\/\/www.boe.es\/buscar\/act.php?id=BOE-A-2002-18099\" target=\"_blank\" rel=\"noopener\">R\u00e9glementation \u00e9lectrotechnique relative \u00e0 la basse tension<\/a> exige que le syst\u00e8me non destin\u00e9 \u00e0 l'exportation soit conforme aux exigences applicables en mati\u00e8re de contr\u00f4le et d'essais. Ces r\u00e8gles modifient l'essai de r\u00e9ception sur site, et non la plaque signal\u00e9tique ESSA.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-70fee1a0 auto-h3 elementor-widget elementor-widget-heading\" data-id=\"70fee1a0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Fixer l'exportation \u00e0 z\u00e9ro au-del\u00e0 du niveau d'optimisation \u00e9conomique<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4fd7836f auto-p elementor-widget elementor-widget-heading\" data-id=\"4fd7836f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Utilisez cette priorit\u00e9 de commande :<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b55d010e elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"b55d010e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Conserver la limite d'exportation obligatoire au point de connexion.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Pr\u00e9server les objectifs d'importation de la cave pendant les pics de vendanges.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Recharger \u00e0 partir de l'exc\u00e9dent solaire disponible tout en respectant le niveau de charge (SOC) et les limites de puissance.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Conservez suffisamment d'\u00e9nergie pour la prochaine op\u00e9ration de production pr\u00e9vue.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-94eaaafe auto-p elementor-widget elementor-widget-heading\" data-id=\"94eaaafe\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">MegSolid int\u00e8gre les fonctions EMS et le canal de communication RS485\/TCP-IP au sein m\u00eame du produit. Le compteur PCC externe, le contr\u00f4leur de site, l'onduleur photovolta\u00efque existant et le dispositif de protection n\u00e9cessitent toutefois une mise en service coordonn\u00e9e. Le <strong><a href=\"https:\/\/www.solidess.com\/fr\/comment-specifier-un-controle-de-zero-injection-au-pcc-pour-un-systeme-de-stockage-denergie-par-batterie-bess\/\" target=\"_blank\" style=\"color:#61ce70\">fronti\u00e8re sans contr\u00f4le des exportations<\/a><\/strong> doit \u00eatre mesur\u00e9e au bon endroit, et la <strong><a href=\"https:\/\/www.solidess.com\/fr\/bess-ct-mesure-de-la-polarite-mise-en-service\/\" target=\"_blank\" style=\"color:#61ce70\">Test de polarit\u00e9 CT<\/a><\/strong> il faut s'assurer que les commandes \u00ab import \u00bb et \u00ab export \u00bb sont interpr\u00e9t\u00e9es dans le bon sens.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2894cf5b auto-p elementor-widget elementor-widget-heading\" data-id=\"2894cf5b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Le <strong><a href=\"https:\/\/www.solidess.com\/fr\/logique-de-priorite-bess-ems\/\" target=\"_blank\" style=\"color:#61ce70\">Hi\u00e9rarchie des priorit\u00e9s des services m\u00e9dicaux d'urgence<\/a><\/strong> emp\u00eache qu'une commande de tarification \u00e9conomique ne d\u00e9passe la limite d'exportation approuv\u00e9e ou ne g\u00e9n\u00e8re un nouveau pic d'importation.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-58d09e44 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"58d09e44\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">D\u00e9finir le p\u00e9rim\u00e8tre des installations \u00e9lectriques et de g\u00e9nie civil de 400 V<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8c03e48a auto-h3 elementor-widget elementor-widget-heading\" data-id=\"8c03e48a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">V\u00e9rifier l'alimentation 400 V et l'emplacement des \u00e9quipements<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f1fe391a auto-p elementor-widget elementor-widget-heading\" data-id=\"f1fe391a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Le mod\u00e8le ESSA0100B-0215 offre un <strong>Interface CA de 400 V nominal<\/strong>, <strong>Courant alternatif nominal de 144 A<\/strong>, un syst\u00e8me de refroidissement par air intelligent et un <strong>IP54<\/strong> bo\u00eetier. Ses dimensions indiqu\u00e9es sont les suivantes : <strong>2 450 \u00d7 1 550 \u00d7 2 400 mm<\/strong>, et son poids est de <strong>3 900 kg<\/strong>. Les valeurs publi\u00e9es d\u00e9finissent l'ensemble des installations \u00e9lectriques et de g\u00e9nie civil \u00e0 mettre en place sur le chantier.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7efa0417 auto-table elementor-widget elementor-widget-text-editor\" data-id=\"7efa0417\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"cea-table-wrap\"><table><thead><tr><th>P\u00e9rim\u00e8tre de l'installation<\/th><th>ESSA0050B-0100<\/th><th>ESSA0100B-0215<\/th><th>Impact sur les clients<\/th><\/tr><\/thead><tbody><tr><td>Puissance nominale en courant alternatif<\/td><td>50 kW<\/td><td>100 kW<\/td><td>L'ESSA100 comble le vide dans la gamme des 75 kW<\/td><\/tr><tr><td>Courant alternatif nominal<\/td><td>72 A<\/td><td>144 A<\/td><td>Modifications des caract\u00e9ristiques nominales des alimentations et des dispositifs de protection<\/td><\/tr><tr><td>Capacit\u00e9 nominale de la batterie<\/td><td>100,352 kWh<\/td><td>215,04 kWh<\/td><td>L'ESSA100 r\u00e9pond aux exigences de la classe \u00e9nerg\u00e9tique requise<\/td><\/tr><tr><td>Dimensions, L \u00d7 P \u00d7 H<\/td><td>1 770 \u00d7 1 510 \u00d7 2 270 mm<\/td><td>2 450 \u00d7 1 550 \u00d7 2 400 mm<\/td><td>L'ESSA100 a besoin d'un emplacement plus spacieux pour son \u00e9quipement<\/td><\/tr><tr><td>Poids<\/td><td>2 400 kg<\/td><td>3 900 kg<\/td><td>Le plan de fondation et de manutention doit pr\u00e9voir une capacit\u00e9 suppl\u00e9mentaire de 1 500 kg<\/td><\/tr><tr><td>Refroidissement \/ bo\u00eetier<\/td><td>Refroidissement par air intelligent \/ IP54<\/td><td>Refroidissement par air intelligent \/ IP54<\/td><td>La temp\u00e9rature ambiante et le d\u00e9bit d'air restent des param\u00e8tres d'acceptation<\/td><\/tr><\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3a558f1c auto-p elementor-widget elementor-widget-heading\" data-id=\"3a558f1c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Le <strong><a href=\"https:\/\/www.solidess.com\/fr\/connexion-de-batterie-400-v-au-tableau-electrique-existant\/\" target=\"_blank\" style=\"color:#61ce70\">raccordement existant au tableau \u00e9lectrique de 400 V<\/a><\/strong> Il convient de v\u00e9rifier le courant continu, la coordination des protections, le niveau de d\u00e9faut, l'isolation et le trac\u00e9 des c\u00e2bles. Le transformateur d'isolation int\u00e9gr\u00e9 constitue un avantage de la solution MegSolid, mais il ne dispense pas de v\u00e9rifier l'ensemble de la conception des protections du site.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2fbd093d auto-h2 elementor-widget elementor-widget-heading\" data-id=\"2fbd093d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Pr\u00e9voyez de recharger vos batteries avant la prochaine r\u00e9colte ou la prochaine soir\u00e9e<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9dfc8806 auto-p elementor-widget elementor-widget-heading\" data-id=\"9dfc8806\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Le lissage des pics ne peut se reproduire de mani\u00e8re fiable que si l\u2019armoire dispose d\u2019une quantit\u00e9 suffisante d\u2019\u00e9nergie utilisable au d\u00e9but de chaque \u00e9v\u00e9nement. Apr\u00e8s avoir fourni 136,25 kWh en courant alternatif, le syst\u00e8me doit r\u00e9cup\u00e9rer plus de 136,25 kWh \u00e0 sa limite de charge, car les pertes de conversion et les \u00e9quipements auxiliaires consomment une partie de l\u2019\u00e9nergie d\u2019entr\u00e9e.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a15ddaa1 auto-h3 elementor-widget elementor-widget-heading\" data-id=\"a15ddaa1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Rapprocher la recharge de l'\u00e9v\u00e9nement suivant<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-eff2edb1 auto-p elementor-widget elementor-widget-heading\" data-id=\"eff2edb1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">La cave devrait comparer trois enregistrements synchronis\u00e9s :<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9e55fe38 elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"9e55fe38\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">exc\u00e9dent photovolta\u00efque disponible avant le prochain \u00e9v\u00e9nement ;<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">marge d\u2019importation autoris\u00e9e vers le r\u00e9seau pendant la recharge ;<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">le niveau de charge (SOC) de la batterie mesur\u00e9 et la puissance CA r\u00e9elle du syst\u00e8me de stockage d'\u00e9nergie par batterie (BESS).<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d0e0396e auto-p elementor-widget elementor-widget-heading\" data-id=\"d0e0396e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Les fonctions de pr\u00e9vision de la capacit\u00e9 de la batterie et de la dur\u00e9e de d\u00e9charge de MegSolid viennent \u00e9tayer ce plan d'exploitation. Le <strong><a href=\"https:\/\/www.solidess.com\/fr\/test-de-capacite-du-bess-commercial-pour-verifier-les-kwh-utilisables\/\" target=\"_blank\" style=\"color:#61ce70\">test de capacit\u00e9 utile du courant alternatif<\/a><\/strong> Il faut ensuite v\u00e9rifier que le mod\u00e8le ESSA0100B-0215 est capable de fournir la s\u00e9quence promise dans les conditions de temp\u00e9rature, de SOC et d'alimentation propres au site.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-19d0396d auto-p elementor-widget elementor-widget-heading\" data-id=\"19d0396d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">L'armoire doit d\u00e9marrer l'\u00e9v\u00e9nement suivant avec suffisamment d'\u00e9nergie disponible pour r\u00e9p\u00e9ter la fonction de r\u00e9gulation de pointe de 75 kW et la s\u00e9quence de production compl\u00e8te. Sans recharge suffisante avant l'\u00e9v\u00e9nement suivant, l'armoire ne pourra pas r\u00e9it\u00e9rer cette performance, quelle que soit sa puissance nominale.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-fdeacbb0 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"fdeacbb0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">N'installez le syst\u00e8me MegSolid de taille inf\u00e9rieure ou sup\u00e9rieure qu'au niveau de la limite appropri\u00e9e.<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f15fcb66 auto-h3 elementor-widget elementor-widget-heading\" data-id=\"f15fcb66\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Veiller \u00e0 ce que l'ESSA0050B-0100 reste en dessous du seuil de 50 kW<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1fd22cd7 auto-p elementor-widget elementor-widget-heading\" data-id=\"1fd22cd7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">MegSolid recommande <strong>ESSA0050B-0100<\/strong> lorsque la r\u00e9duction mesur\u00e9e de la consommation d'\u00e9lectricit\u00e9 ne d\u00e9passe pas 50 kW et que l'\u00e9nergie CA utilisable v\u00e9rifi\u00e9e couvre l'int\u00e9gralit\u00e9 de l'\u00e9v\u00e9nement. Ce r\u00e9gime peut utiliser la plus petite des deux valeurs <strong>72 A<\/strong>, <strong>2 400 kg<\/strong> armoire sans encombrement inutile en termes de puissance et de capacit\u00e9 \u00e9nerg\u00e9tique.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4265988f auto-p elementor-widget elementor-widget-heading\" data-id=\"4265988f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">MegSolid recommande <strong>ESSA0100B-0215<\/strong> lorsque le d\u00e9ficit d\u00e9passe 50 kW, que la s\u00e9quence de fonctionnement d\u00e9passe la plage d'\u00e9nergie utilisable de l'armoire la plus petite, ou lorsque ces deux conditions sont r\u00e9unies. La cave \u00e9valu\u00e9e d\u00e9passe ces deux limites \u00e0 <strong>75 kW<\/strong> et <strong>136,25 kWh CA<\/strong>, c'est donc l'armoire de 100 kW \/ 215,04 kWh qu'il convient d'acheter.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9c24e5d2 auto-h3 elementor-widget elementor-widget-heading\" data-id=\"9c24e5d2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Ne d\u00e9passez la valeur ESSA100 que lorsque la charge mesur\u00e9e l'exige<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4fc3ca3e auto-p elementor-widget elementor-widget-heading\" data-id=\"4fc3ca3e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Les projets dont la puissance d\u00e9passe 100 kW ou qui ne peuvent pas s'inscrire dans la fourchette d'\u00e9nergie utile requise par ESSA100 n\u00e9cessitent une architecture plus importante. MegSolid\u2019s <strong><a href=\"https:\/\/www.solidess.com\/fr\/product\/stockage-denergie-solide-liquide-megasolide\/\" target=\"_blank\" style=\"color:#61ce70\">261,24 kWh \u2013 Plateforme Energon<\/a><\/strong> fournit un <strong>125 kVA<\/strong> cat\u00e9gorie de produits \u00e0 refroidissement liquide ; il ne faut pas consid\u00e9rer automatiquement que 125 kVA \u00e9quivaut \u00e0 125 kW. Les grands sites viticoles devraient proc\u00e9der \u00e0 cette \u00e9tude technique avant de passer commande d'\u00e9quipements.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-06b6f4f9 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"06b6f4f9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Indiquez la r\u00e9f\u00e9rence ESSA0100B-0215 pour les mod\u00e8les de 75 kW et 136,25 kWh en service CA.<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b3e630c8 auto-p elementor-widget elementor-widget-heading\" data-id=\"b3e630c8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Deux limites mesur\u00e9es d\u00e9terminent la classe de l'\u00e9quipement. Le mod\u00e8le ESSA0050B-0100 ne r\u00e9pond pas \u00e0 l'objectif d'importation de <strong>25 kW<\/strong> et la capacit\u00e9 nominale de sa batterie est de <strong>35 898 kWh de moins<\/strong> la puissance active requise avant pertes. Le mod\u00e8le ESSA0100B-0215 fournit la valeur correcte <strong>Classe CA de puissance nominale de 100 kW<\/strong> et <strong>Classe \u00e9nerg\u00e9tique nominale : 215,04 kWh<\/strong> dans une armoire d'ext\u00e9rieur.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d8178bb5 auto-p elementor-widget elementor-widget-heading\" data-id=\"d8178bb5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">L'ESSA0100B-0215 peut \u00eatre test\u00e9 pour une utilisation en mode \u00ab harvest \u00bb \u00e0 pleine charge, r\u00e9utilis\u00e9 pour le \u00ab solar shifting \u00bb hors mode \u00ab harvest \u00bb et int\u00e9gr\u00e9 \u00e0 un syst\u00e8me de contr\u00f4le \u00ab z\u00e9ro exportation \u00bb via un syst\u00e8me de gestion de l'\u00e9nergie (EMS) et une p\u00e9rim\u00e8tre de communication bien d\u00e9finis. Sa connexion de 400 V, 144 A et sa charge d\u2019installation de 3 900 kg sont connues avant l\u2019achat, ce qui permet de concevoir les travaux \u00e9lectriques et de g\u00e9nie civil en fonction de l\u2019armoire r\u00e9elle.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7fe7ed1a elementor-tablet-align-center elementor-align-center auto-cta elementor-widget elementor-widget-button\" data-id=\"7fe7ed1a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"#elementor-action%3Aaction%3Dpopup%3Aopen%26settings%3DeyJpZCI6Ijk0OCIsInRvZ2dsZSI6ZmFsc2V9\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Sp\u00e9cifiez le raccordement ESSA0100B-0215, la fen\u00eatre SOC et la puissance alternative utile avec MegSolid<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-d2ef9ca4 auto-faq e-flex e-con-boxed e-con e-child\" data-id=\"d2ef9ca4\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-874c2f1e elementor-widget elementor-widget-heading\" data-id=\"874c2f1e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">FAQ<\/h2>\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-f7e896ca e-con-full e-flex e-con e-child\" data-id=\"f7e896ca\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-e2c28f28 elementor-widget elementor-widget-n-accordion\" data-id=\"e2c28f28\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;default_state&quot;:&quot;all_collapsed&quot;,&quot;max_items_expended&quot;:&quot;one&quot;,&quot;n_accordion_animation_duration&quot;:{&quot;unit&quot;:&quot;ms&quot;,&quot;size&quot;:400,&quot;sizes&quot;:[]}}\" data-widget_type=\"nested-accordion.default\">\n\t\t\t\t\t\t\t<div class=\"e-n-accordion\" aria-label=\"Accord\u00e9on. Ouvrez les liens \u00e0 l&#039;aide de la touche Entr\u00e9e ou de la barre d&#039;espace, fermez-les avec la touche \u00c9chap et naviguez \u00e0 l&#039;aide des touches fl\u00e9ch\u00e9es.\">\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-3800\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"1\" tabindex=\"0\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-3800\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Quelle batterie MegSolid est recommand\u00e9e pour un domaine viticole espagnol pr\u00e9sentant un d\u00e9ficit de puissance de pointe de 75 kW ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3800\" class=\"elementor-element elementor-element-d43743c7 e-con-full e-flex e-con e-child\" data-id=\"d43743c7\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3800\" class=\"elementor-element elementor-element-77ab4584 e-con-full e-flex e-con e-child\" data-id=\"77ab4584\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a1c98da5 elementor-widget elementor-widget-heading\" data-id=\"a1c98da5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">MegSolid recommande le mod\u00e8le ESSA0100B-0215. Sa puissance nominale en courant alternatif de 100 kW d\u00e9passe le d\u00e9ficit mesur\u00e9 de 75 kW, tandis que le mod\u00e8le ESSA0050B-0100, d'une puissance de 50 kW, pr\u00e9sente un d\u00e9ficit de 25 kW.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-3801\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"2\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-3801\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Pourquoi le mod\u00e8le ESSA0100B-0215 est-il mieux adapt\u00e9 \u00e0 une charge CA de 136,25 kWh ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3801\" class=\"elementor-element elementor-element-07839ed8 e-con-full e-flex e-con e-child\" data-id=\"07839ed8\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3801\" class=\"elementor-element elementor-element-04825c9e e-con-full e-flex e-con e-child\" data-id=\"04825c9e\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ce29074a elementor-widget elementor-widget-heading\" data-id=\"ce29074a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Sa capacit\u00e9 nominale de 215,04 kWh assure la classe d'\u00e9nergie nominale appropri\u00e9e pour l'ensemble de la s\u00e9quence. La capacit\u00e9 nominale de 100,352 kWh de l'armoire plus petite est d\u00e9j\u00e0 inf\u00e9rieure de 35,898 kWh \u00e0 la puissance CA requise avant pertes.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-3802\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"3\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-3802\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Dans quels cas le mod\u00e8le ESSA0050B-0100 est-il le meilleur produit MegSolid ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3802\" class=\"elementor-element elementor-element-de6430f1 e-con-full e-flex e-con e-child\" data-id=\"de6430f1\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3802\" class=\"elementor-element elementor-element-0985f287 e-con-full e-flex e-con e-child\" data-id=\"0985f287\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-153bb9b0 elementor-widget elementor-widget-heading\" data-id=\"153bb9b0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">La correspondance est d\u2019autant plus pr\u00e9cise que la r\u00e9duction des importations mesur\u00e9e reste inf\u00e9rieure \u00e0 50 kW et que l\u2019\u00e9v\u00e9nement dans son ensemble s\u2019inscrit dans la plage d\u2019\u00e9nergie CA utilisable v\u00e9rifi\u00e9e.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-3803\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"4\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-3803\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Un parc photovolta\u00efque de 100 kWc n\u00e9cessite-t-il un syst\u00e8me de stockage d'\u00e9nergie (BESS) de 100 kW ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3803\" class=\"elementor-element elementor-element-cf93b60c e-con-full e-flex e-con e-child\" data-id=\"cf93b60c\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3803\" class=\"elementor-element elementor-element-2d4d0062 e-con-full e-flex e-con e-child\" data-id=\"2d4d0062\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-82ef24b2 elementor-widget elementor-widget-heading\" data-id=\"82ef24b2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Non. La puissance du BESS suit le d\u00e9ficit d'importation mesur\u00e9 et la limite de charge. L'\u00e9nergie du BESS suit la plage de d\u00e9charge, l'exc\u00e9dent solaire utilisable et la r\u00e9serve de SOC requise.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-3804\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"5\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-3804\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> L'\u00e9nergie nominale d'une batterie peut-elle \u00eatre consid\u00e9r\u00e9e comme de l'\u00e9nergie CA utilisable ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3804\" class=\"elementor-element elementor-element-e01a5218 e-con-full e-flex e-con e-child\" data-id=\"e01a5218\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3804\" class=\"elementor-element elementor-element-e896ceef e-con-full e-flex e-con e-child\" data-id=\"e896ceef\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-105af9bc elementor-widget elementor-widget-heading\" data-id=\"105af9bc\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Non. L'\u00e9nergie CA fournie d\u00e9pend de la plage de SOC convenue, des pertes de conversion, des charges auxiliaires, de la temp\u00e9rature et de la puissance de d\u00e9charge. La mise en service doit permettre de v\u00e9rifier la limite CA.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-3805\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"6\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-3805\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Le mod\u00e8le ESSA0100B-0215 est-il compatible avec les installations solaires existantes des domaines viticoles ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3805\" class=\"elementor-element elementor-element-7ea7e4e1 e-con-full e-flex e-con e-child\" data-id=\"7ea7e4e1\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3805\" class=\"elementor-element elementor-element-ca0f939c e-con-full e-flex e-con e-child\" data-id=\"ca0f939c\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-52f7677c elementor-widget elementor-widget-heading\" data-id=\"52f7677c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Oui, une installation \u00e0 couplage en courant alternatif permet de conserver les \u00e9quipements photovolta\u00efques existants adapt\u00e9s, \u00e0 condition que le tableau \u00e9lectrique, les dispositifs de protection, les compteurs et les syst\u00e8mes de commande soient compatibles avec cette configuration.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-3806\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"7\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-3806\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Le bo\u00eetier ESSA permet-il \u00e0 lui seul de bloquer toute exportation ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3806\" class=\"elementor-element elementor-element-a72db2ef e-con-full e-flex e-con e-child\" data-id=\"a72db2ef\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3806\" class=\"elementor-element elementor-element-c178c6f9 e-con-full e-flex e-con e-child\" data-id=\"c178c6f9\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-e9160bac elementor-widget elementor-widget-heading\" data-id=\"e9160bac\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Non. L'armoire assure les fonctions EMS et de communication, tandis que le compteur PCC, le contr\u00f4leur de site, l'onduleur photovolta\u00efque, les dispositifs de protection et le m\u00e9canisme anti-exportation doivent passer avec succ\u00e8s l'essai coordonn\u00e9 sur site.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-3807\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"8\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-3807\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Quelle interface \u00e9lectrique l'ESSA0100B-0215 offre-t-elle ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3807\" class=\"elementor-element elementor-element-cd184a8c e-con-full e-flex e-con e-child\" data-id=\"cd184a8c\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3807\" class=\"elementor-element elementor-element-18ff9a9a e-con-full e-flex e-con e-child\" data-id=\"18ff9a9a\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-6e1d5e76 elementor-widget elementor-widget-heading\" data-id=\"6e1d5e76\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">MegSolid publie une interface CA d'une tension nominale de 400 V et un courant CA nominal de 144 A pour le mod\u00e8le ESSA0100B-0215. La conception du tableau \u00e9lectrique et des protections existantes doit \u00eatre v\u00e9rifi\u00e9e au regard de ces limites.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-3808\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"9\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-3808\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Le mod\u00e8le ESSA0100B-0215 est-il refroidi par liquide ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3808\" class=\"elementor-element elementor-element-dc512471 e-con-full e-flex e-con e-child\" data-id=\"dc512471\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3808\" class=\"elementor-element elementor-element-3df185a8 e-con-full e-flex e-con e-child\" data-id=\"3df185a8\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-fa01864a elementor-widget elementor-widget-heading\" data-id=\"fa01864a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Non. MegSolid propose un syst\u00e8me de refroidissement par air intelligent pour le mod\u00e8le ESSA0100B-0215. Le syst\u00e8me Energon de 261,24 kWh appartient \u00e0 une cat\u00e9gorie distincte de produits \u00e0 refroidissement liquide.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-3809\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"10\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-3809\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Quelles sont les dimensions et le poids du mod\u00e8le ESSA0100B-0215 ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3809\" class=\"elementor-element elementor-element-df512d14 e-con-full e-flex e-con e-child\" data-id=\"df512d14\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3809\" class=\"elementor-element elementor-element-70f87163 e-con-full e-flex e-con e-child\" data-id=\"70f87163\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ac81eebd elementor-widget elementor-widget-heading\" data-id=\"ac81eebd\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Ses dimensions officielles sont de 2 450 \u00d7 1 550 \u00d7 2 400 mm, et son poids officiel est de 3 900 kg.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-38010\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"11\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-38010\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Comment le domaine viticole se pr\u00e9pare-t-il \u00e0 affronter un deuxi\u00e8me pic d'activit\u00e9 ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-38010\" class=\"elementor-element elementor-element-12b5f3b6 e-con-full e-flex e-con e-child\" data-id=\"12b5f3b6\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-38010\" class=\"elementor-element elementor-element-cad88909 e-con-full e-flex e-con e-child\" data-id=\"cad88909\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c4fa68d7 elementor-widget elementor-widget-heading\" data-id=\"c4fa68d7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Le syst\u00e8me EMS utilise l'exc\u00e9dent photovolta\u00efque disponible ou la marge d'importation autoris\u00e9e depuis le r\u00e9seau, tout en respectant les limites d'importation et d'exportation. La mise en correspondance de l'\u00e9tat de charge (SOC), de la puissance du PCC, de la production photovolta\u00efque et de la puissance du BESS permet de d\u00e9terminer si la fen\u00eatre de recharge est ferm\u00e9e.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-38011\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"12\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-38011\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Quelles sont les r\u00e8gles espagnoles applicables \u00e0 un domaine viticole BESS n'effectuant aucune exportation ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-38011\" class=\"elementor-element elementor-element-b99a7ad9 e-con-full e-flex e-con e-child\" data-id=\"b99a7ad9\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-38011\" class=\"elementor-element elementor-element-6d248aba e-con-full e-flex e-con e-child\" data-id=\"6d248aba\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-51b5ce91 elementor-widget elementor-widget-heading\" data-id=\"51b5ce91\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Le d\u00e9cret royal 244\/2019 d\u00e9finit la notion d'autoconsommation sans exc\u00e9dent, et la norme ITC-BT-40 modifi\u00e9e \u00e9tablit les exigences et les essais applicables au m\u00e9canisme emp\u00eachant l'injection dans le r\u00e9seau de distribution.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-38012\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"13\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-38012\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Quels avantages le MegSolid ESSA100 apporte-t-il \u00e0 la cave ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-38012\" class=\"elementor-element elementor-element-0fc6b808 e-con-full e-flex e-con e-child\" data-id=\"0fc6b808\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-38012\" class=\"elementor-element elementor-element-c226037f e-con-full e-flex e-con e-child\" data-id=\"c226037f\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ef11b8e5 elementor-widget elementor-widget-heading\" data-id=\"ef11b8e5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Il r\u00e9pond \u00e0 l'exigence de puissance d\u00e9finie de 75 kW et offre la classe d'\u00e9nergie nominale de 215,04 kWh n\u00e9cessaire pour tester l'int\u00e9gralit\u00e9 de la s\u00e9quence CA de 136,25 kWh, tout en int\u00e9grant les fonctions EMS, les communications et un transformateur d'isolement au sein d'une seule et m\u00eame plateforme ext\u00e9rieure.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Installation du MegSolid ESSA0100B-0215 pour une cave espagnole n\u00e9cessitant une r\u00e9duction de la puissance de pointe de 75 kW et une consommation de 136,25 kWh en courant alternatif, avec int\u00e9gration d'une installation solaire, sans exportation d'\u00e9nergie et en 400 V.<\/p>","protected":false},"author":4,"featured_media":5521,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"_joinchat":[],"footnotes":""},"categories":[1,714],"tags":[707,702,184,703,704,705,706],"class_list":["post-5524","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-bess","category-ci-battery-storage-solutions","tag-400-v-bess-winery","tag-battery-storage-for-spanish-wineries","tag-essa0100b-0215","tag-spanish-winery-battery-storage","tag-winery-peak-shaving","tag-winery-solar-battery-storage","tag-zero-export-bess-spain"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/posts\/5524","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/comments?post=5524"}],"version-history":[{"count":6,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/posts\/5524\/revisions"}],"predecessor-version":[{"id":5531,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/posts\/5524\/revisions\/5531"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/media\/5521"}],"wp:attachment":[{"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/media?parent=5524"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/categories?post=5524"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/tags?post=5524"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}