{"id":5540,"date":"2026-09-25T09:55:24","date_gmt":"2026-09-25T01:55:24","guid":{"rendered":"https:\/\/www.solidess.com\/?p=5540"},"modified":"2026-10-14T04:14:00","modified_gmt":"2026-10-13T20:14:00","slug":"machines-de-moulage-par-injection-de-plastique-pour-le-stockage-denergie-par-batterie-ci","status":"publish","type":"post","link":"https:\/\/www.solidess.com\/fr\/ci-battery-storage-plastic-injection-molding-machines\/","title":{"rendered":"R\u00e9duire les p\u00e9nalit\u00e9s de d\u00e9passement de puissance souscrite gr\u00e2ce au stockage par batteries dans les usines de moulage par injection plastique"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"5540\" class=\"elementor elementor-5540\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-bf4793c e-con-full auto-article-root e-flex e-con e-parent\" data-id=\"bf4793c\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-75b027d7 auto-image elementor-widget elementor-widget-image\" data-id=\"75b027d7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"1254\" height=\"1254\" src=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Injection-Molding-Capacity-Fines-Cover.jpg\" class=\"attachment-1536x1536 size-1536x1536 wp-image-5537\" alt=\"Syst\u00e8me de stockage d&#039;\u00e9nergie MegSolid C&amp;I destin\u00e9 aux presses \u00e0 injection de plastique, permettant de r\u00e9duire les pics de demande de PCC de 680 kW \u00e0 une limite contractuelle de 500 kW, avec un besoin de d\u00e9charge du syst\u00e8me de stockage d&#039;\u00e9nergie (BESS) de 180 kW\" srcset=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Injection-Molding-Capacity-Fines-Cover.jpg 1254w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Injection-Molding-Capacity-Fines-Cover-300x300.jpg 300w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Injection-Molding-Capacity-Fines-Cover-1024x1024.jpg 1024w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Injection-Molding-Capacity-Fines-Cover-150x150.jpg 150w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Injection-Molding-Capacity-Fines-Cover-768x768.jpg 768w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Injection-Molding-Capacity-Fines-Cover-12x12.jpg 12w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Injection-Molding-Capacity-Fines-Cover-600x600.jpg 600w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Injection-Molding-Capacity-Fines-Cover-100x100.jpg 100w\" sizes=\"(max-width: 1254px) 100vw, 1254px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c1f619fd auto-p elementor-widget elementor-widget-heading\" data-id=\"c1f619fd\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Si une usine de moulage atteint 680 kW avec une limite de soutirage de 500 kW, une armoire de 100 kW ne peut pas compenser \u00e0 elle seule les 180 kW de d\u00e9passement. \u00c9valuez ensemble la puissance \u00e0 fournir et la dur\u00e9e du pic. Les PCS MEGA de MegSolid couvrent une plage de puissance en courant alternatif plus \u00e9lev\u00e9e, et les syst\u00e8mes industriels ESSC offrent des configurations int\u00e9gr\u00e9es de plus grande taille. Transmettez les courbes de charge \u00e9lectrique des machines sur la m\u00eame p\u00e9riode ainsi que la puissance de soutirage autoris\u00e9e sur le site. Cela permet de comparer des \u00e9quipements capables de couvrir la p\u00e9riode de production concern\u00e9e, plut\u00f4t que de choisir une batterie uniquement d\u2019apr\u00e8s sa capacit\u00e9 en kWh.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7a541560 auto-p elementor-widget elementor-widget-heading\" data-id=\"7a541560\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Le stockage par batteries de MegSolid pour sites commerciaux et industriels (C&amp;I) fournit cet appoint temporaire de puissance derri\u00e8re le compteur.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c8183a9a auto-h3 elementor-widget elementor-widget-heading\" data-id=\"c8183a9a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Calculer le d\u00e9passement de puissance au point de couplage commun (PCC)<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8ef2b35c auto-p elementor-widget elementor-widget-heading\" data-id=\"8ef2b35c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Si l\u2019usine appelle 680 kW alors que sa puissance souscrite est de 500 kW, le site pr\u00e9sente un <strong>d\u00e9passement de 180 kW<\/strong>:<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-cb6417ec auto-p elementor-widget elementor-widget-heading\" data-id=\"cb6417ec\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\"><strong>680 kW \u2212 500 kW = 180 kW de puissance de d\u00e9charge requise pour le syst\u00e8me de stockage d'\u00e9nergie par batterie (BESS)<\/strong><\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b8beabe2 auto-p elementor-widget elementor-widget-heading\" data-id=\"b8beabe2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default translation-block\">Choisissez la gamme MegSolid en fonction de l\u2019\u00e9cart mesur\u00e9 : <a href=\"https:\/\/www.solidess.com\/fr\/armoire-dexterieur-ess-de-100-kw-et-215-kwh\/\" style=\"color:#61ce70\" target=\"_self\">ESSA0100B-0215<\/a> pour \u00e9cr\u00eater jusqu\u2019\u00e0 100 kW, <a href=\"https:\/\/www.solidess.com\/fr\/product\/stockage-denergie-solide-liquide-megasolide\/\" style=\"color:#61ce70\" target=\"_self\">Energon 261<\/a> pour disposer d\u2019une capacit\u00e9 \u00e9nerg\u00e9tique sup\u00e9rieure par armoire, <a href=\"https:\/\/www.solidess.com\/fr\/product\/systeme-de-conversion-denergie-megsolid\/\" style=\"color:#61ce70\" target=\"_self\">MEGA PCS<\/a> pour des besoins de 150 \u00e0 500 kW, et <a href=\"https:\/\/www.solidess.com\/fr\/product\/systeme-de-stockage-denergie-conteneurise\/\" style=\"color:#61ce70\" target=\"_self\">BESS ESSC en conteneur<\/a> pour des pointes de 500 kW \u00e0 1 MW \u00e0 l\u2019\u00e9chelle de l\u2019usine.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b31be8ac auto-h2 elementor-widget elementor-widget-heading\" data-id=\"b31be8ac\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Les pointes de production simultan\u00e9es peuvent entra\u00eener des p\u00e9nalit\u00e9s de d\u00e9passement<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2989977c auto-p elementor-widget elementor-widget-heading\" data-id=\"2989977c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">La puissance appel\u00e9e par les presses \u00e0 injection varie pendant chaque cycle de production. Les mouvements du m\u00e9canisme de fermeture, l\u2019injection, le maintien en pression, le recul de la vis pendant le dosage, le chauffage du cylindre, les pompes hydrauliques, les servom\u00e9canismes, les refroidisseurs, les s\u00e9cheurs et les compresseurs cr\u00e9ent des pointes r\u00e9currentes. Le d\u00e9passement devient co\u00fbteux lorsque plusieurs pointes co\u00efncident et que la puissance totale appel\u00e9e par l\u2019usine franchit la limite au PCC.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f4e3ebbb auto-h3 elementor-widget elementor-widget-heading\" data-id=\"f4e3ebbb\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Mesurer le profil de puissance du cycle de moulage par injection<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9c1b2f4a auto-p elementor-widget elementor-widget-heading\" data-id=\"9c1b2f4a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">La force de fermeture nominale des presses ne suffit pas \u00e0 dimensionner un syst\u00e8me de stockage d\u2019\u00e9nergie par batteries (BESS). \u00c0 force de fermeture comparable, les presses hydrauliques, servo-hydrauliques et enti\u00e8rement \u00e9lectriques peuvent pr\u00e9senter des profils de puissance diff\u00e9rents.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4c65624b auto-p elementor-widget elementor-widget-heading\" data-id=\"4c65624b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\"><strong>S\u00e9quence de dimensionnement :<\/strong> cycle de la presse \u2192 charge \u00e9lectrique combin\u00e9e de l\u2019usine \u2192 pointe au PCC \u2192 d\u00e9passement de la puissance souscrite \u2192 puissance requise du BESS.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-60b231cf auto-p elementor-widget elementor-widget-heading\" data-id=\"60b231cf\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Si la puissance appel\u00e9e par l\u2019usine passe de 450 kW \u00e0 610 kW alors que la limite est de 500 kW, le BESS doit fournir environ 110 kW en d\u00e9charge. Des relev\u00e9s plus fins permettent d\u2019identifier les presses ou les auxiliaires \u00e0 l\u2019origine de la pointe.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a36952be auto-h3 elementor-widget elementor-widget-heading\" data-id=\"a36952be\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Distinguer les courants transitoires de d\u00e9marrage des frais de puissance et des p\u00e9nalit\u00e9s de d\u00e9passement<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b399df09 auto-p elementor-widget elementor-widget-heading\" data-id=\"b399df09\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Les frais d\u2019\u00e9nergie d\u00e9pendent des kWh consomm\u00e9s. Les frais de puissance d\u00e9pendent de la plus forte puissance mesur\u00e9e en kW ou en kVA, selon l\u2019intervalle de mesure d\u00e9fini par le fournisseur. Les p\u00e9nalit\u00e9s de d\u00e9passement s\u2019appliquent uniquement si le tarif ou le contrat de raccordement p\u00e9nalise une puissance appel\u00e9e sup\u00e9rieure \u00e0 la limite souscrite.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b4c90e42 auto-p elementor-widget elementor-widget-heading\" data-id=\"b4c90e42\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Un bref courant d\u2019appel au d\u00e9marrage d\u2019un moteur ne se traduit pas n\u00e9cessairement par une pointe de puissance factur\u00e9e sur 15 minutes. Le co\u00fbt intervient lorsque la charge reste \u00e9lev\u00e9e ou se r\u00e9p\u00e8te. Si la puissance appel\u00e9e atteint 620 kW alors que la limite est de 500 kW, le BESS doit fournir environ 120 kW.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ff9ee081 auto-p elementor-widget elementor-widget-heading\" data-id=\"ff9ee081\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default translation-block\">La <a href=\"https:\/\/www.solidess.com\/fr\/controle-de-lecretement-des-pics-de-charge-de-la-batterie-pcc\/\" style=\"color:#61ce70\" target=\"_self\">commande d\u2019\u00e9cr\u00eatage des pointes de MegSolid au point de couplage commun (PCC)<\/a> cible pr\u00e9cis\u00e9ment cet \u00e9cart au lieu de d\u00e9charger la batterie \u00e0 une puissance fixe arbitraire.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2e1878d4 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"2e1878d4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Utiliser le stockage par batteries pour maintenir le soutirage au PCC sous la limite contractuelle<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7371b209 auto-image elementor-widget elementor-widget-image\" data-id=\"7371b209\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"1448\" height=\"1086\" src=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Injection-Molding-Peak-Shaving-Engineering-Proof.jpg\" class=\"attachment-1536x1536 size-1536x1536 wp-image-5539\" alt=\"D\u00e9cision relative au choix de la gamme de produits MegSolid pour les usines de moulage par injection, comparant les mod\u00e8les ESSA0100B-0215, Energon 261, MEGA PCS et ESSC (syst\u00e8me de stockage d&#039;\u00e9nergie par batterie en conteneur) en fonction de la r\u00e9duction des pics mesur\u00e9e, de la charge en kVA, de la dur\u00e9e des \u00e9v\u00e9nements et de la fen\u00eatre de recharge\" srcset=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Injection-Molding-Peak-Shaving-Engineering-Proof.jpg 1448w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Injection-Molding-Peak-Shaving-Engineering-Proof-300x225.jpg 300w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Injection-Molding-Peak-Shaving-Engineering-Proof-1024x768.jpg 1024w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Injection-Molding-Peak-Shaving-Engineering-Proof-768x576.jpg 768w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Injection-Molding-Peak-Shaving-Engineering-Proof-16x12.jpg 16w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Injection-Molding-Peak-Shaving-Engineering-Proof-600x450.jpg 600w\" sizes=\"(max-width: 1448px) 100vw, 1448px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f4d8a4aa auto-p elementor-widget elementor-widget-heading\" data-id=\"f4d8a4aa\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Derri\u00e8re le compteur, le BESS fournit la part de la puissance appel\u00e9e par l\u2019usine qui d\u00e9passe le seuil de soutirage retenu. Le contr\u00f4le au point de couplage commun (PCC) utilise cet \u00e9cart pour fixer la puissance de d\u00e9charge.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-978faa0d auto-h3 elementor-widget elementor-widget-heading\" data-id=\"978faa0d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Piloter l\u2019\u00e9cr\u00eatage des pointes \u00e0 partir des mesures au PCC<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c722567d auto-p elementor-widget elementor-widget-heading\" data-id=\"c722567d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\"><strong>Cha\u00eene de contr\u00f4le :<\/strong> Compteur au PCC \u2192 EMS \u2192 PCS \u2192 d\u00e9charge de la batterie \u2192 baisse de la puissance soutir\u00e9e au r\u00e9seau.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4a4e6331 auto-p elementor-widget elementor-widget-heading\" data-id=\"4a4e6331\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Lorsque la puissance appel\u00e9e approche du plafond, le PCS augmente la puissance de d\u00e9charge. Lorsque la demande baisse, il r\u00e9duit la puissance fournie. La recharge doit rester dans la marge de puissance disponible sur le raccordement.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3a2c679a auto-p elementor-widget elementor-widget-heading\" data-id=\"3a2c679a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default translation-block\">Un PCS de 100 kW ne peut pas compenser un d\u00e9passement continu de 170 kW. La puissance du PCS MEGA de MegSolid doit correspondre au d\u00e9ficit r\u00e9el de puissance de l\u2019usine, tandis que la <a href=\"https:\/\/www.solidess.com\/fr\/logique-de-priorite-bess-ems\/\" style=\"color:#61ce70\" target=\"_self\">logique de priorit\u00e9 de l\u2019EMS<\/a> coordonne l\u2019\u00e9cr\u00eatage des pointes, la recharge, l\u2019\u00e9tat de charge (SOC) et les autres limites d\u2019exploitation.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-15cdba13 auto-h3 elementor-widget elementor-widget-heading\" data-id=\"15cdba13\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Utiliser le BESS comme appoint temporaire de puissance avant un renforcement du raccordement<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-96e8afbf auto-p elementor-widget elementor-widget-heading\" data-id=\"96e8afbf\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Supposons qu'une usine existante atteigne une puissance maximale de 720 kW, dispose d'une limite contractuelle de 800 kW et qu'une nouvelle machine de moulage vienne ajouter 160 kW pendant la p\u00e9riode de production critique.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-80628382 auto-p elementor-widget elementor-widget-heading\" data-id=\"80628382\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\"><strong>720 kW + 160 kW = 880 kW<\/strong><\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7ded2d49 auto-p elementor-widget elementor-widget-heading\" data-id=\"7ded2d49\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\"><strong>D\u00e9passement de puissance qui en r\u00e9sulte :<\/strong> 880 kW \u2212 800 kW = <strong>80 kW<\/strong>.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d606328b auto-p elementor-widget elementor-widget-heading\" data-id=\"d606328b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">En fournissant 80 kW, le BESS peut maintenir le soutirage au PCC autour de 800 kW pendant la pointe et permettre de reporter des travaux sur le r\u00e9seau public.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-75b3b0e1 auto-p elementor-widget elementor-widget-heading\" data-id=\"75b3b0e1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Le BESS r\u00e9duit la puissance soutir\u00e9e au r\u00e9seau. Les c\u00e2bles, jeux de barres, disjoncteurs et transformateurs internes doivent toujours supporter la charge \u00e9lectrique r\u00e9elle de l\u2019usine.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-04789535 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"04789535\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Dimensionner la puissance active et apparente du PCS et l\u2019\u00e9nergie de la batterie d\u2019apr\u00e8s la charge de l\u2019usine<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-06ae5f1c auto-h3 elementor-widget elementor-widget-heading\" data-id=\"06ae5f1c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">D\u00e9finir les besoins en courant alternatif avant la capacit\u00e9 de la batterie en kWh<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3645cad8 auto-p elementor-widget elementor-widget-heading\" data-id=\"3645cad8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Relevez quatre param\u00e8tres pour commencer. Il s\u2019agit de la puissance active requise en kW, de la puissance apparente requise en kVA, de la dur\u00e9e de la pointe et de la plage de recharge. D\u00e9terminez ensuite la capacit\u00e9 nominale de la batterie en kWh.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-68406e43 auto-p elementor-widget elementor-widget-heading\" data-id=\"68406e43\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default translation-block\">La <a href=\"https:\/\/www.solidess.com\/fr\/piles\/stockage-denergie-ci\/\" style=\"color:#61ce70\" target=\"_self\">gamme de stockage de MegSolid pour les secteurs commercial et industriel<\/a> couvre diff\u00e9rents niveaux de puissance pour ces usages, avec des armoires, des PCS et des syst\u00e8mes en conteneur.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e2d138a3 auto-h3 elementor-widget elementor-widget-heading\" data-id=\"e2d138a3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Distinguer la puissance d\u2019\u00e9cr\u00eatage de l\u2019\u00e9nergie n\u00e9cessaire pendant la pointe<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-123f6914 auto-p elementor-widget elementor-widget-heading\" data-id=\"123f6914\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">La puissance d\u00e9termine de combien le BESS peut r\u00e9duire la pointe. L\u2019\u00e9nergie d\u00e9termine pendant combien de temps il peut maintenir cette r\u00e9duction.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4e2d49a3 auto-p elementor-widget elementor-widget-heading\" data-id=\"4e2d49a3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Pour r\u00e9duire une pointe de 90 kW pendant 20 minutes, il faut environ 30 kWh avant marge de dimensionnement. Pour maintenir la m\u00eame r\u00e9duction de 90 kW pendant deux heures, il faut environ 180 kWh.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e6c1da12 auto-table elementor-widget elementor-widget-text-editor\" data-id=\"e6c1da12\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"cea-table-wrap\"><table><thead><tr><th>Armoire<\/th><th>Puissance et \u00e9nergie annonc\u00e9es<\/th><th>Batterie \/ refroidissement<\/th><th>Note relative \u00e0 la s\u00e9lection<\/th><\/tr><\/thead><tbody><tr><td>ESSA0100B-0215<\/td><td>100 kW \/ 215,04 kWh<\/td><td>280 Ah LFP, 768 V CC nominal, 0,5 C \u00e0 25 \u00b0C, refroidissement par air, IP54<\/td><td>Armoire adapt\u00e9e aux besoins allant jusqu\u2019\u00e0 100 kW si son \u00e9nergie utile suffit \u00e0 couvrir toute la pointe<\/td><\/tr><tr><td>Energon 261<\/td><td>125 kVA \/ 261,24 kWh<\/td><td>314 Ah LFP, tension nominale de 832 V CC, refroidissement par liquide, indice de protection IP54<\/td><td>Une puissance apparente de 125 kVA ne garantit pas une puissance active constante de 125 kW<\/td><\/tr><\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a51d13f8 auto-h3 elementor-widget elementor-widget-heading\" data-id=\"a51d13f8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Dimensionner la puissance active (kW) et apparente (kVA) du PCS pour les charges motoris\u00e9es<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1bddbadc auto-p elementor-widget elementor-widget-heading\" data-id=\"1bddbadc\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Les installations de moulage par injection comprennent des moteurs, des pompes, des refroidisseurs et des compresseurs ; le dimensionnement des syst\u00e8mes de conversion de puissance (PCS) doit donc tenir compte \u00e0 la fois des kW et des kVA.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9b96ff5f auto-p elementor-widget elementor-widget-heading\" data-id=\"9b96ff5f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">La gamme MEGA PCS couvre des puissances de <strong>30 \u00e0 500 kW<\/strong>, avec une interface \u00e0 400 V CA, une commande des puissances active et r\u00e9active, un transformateur d\u2019isolement int\u00e9gr\u00e9 et un taux de distorsion harmonique du courant (THDi) inf\u00e9rieur \u00e0 3 % en fonctionnement raccord\u00e9 au r\u00e9seau.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-bb7d8600 auto-p elementor-widget elementor-widget-heading\" data-id=\"bb7d8600\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Une r\u00e9duction soutenue de 180 kW d\u00e9passe les capacit\u00e9s d\u2019un PCS de 100 kW. Il faut dimensionner un \u00e9tage de conversion plus puissant. Un surplus de capacit\u00e9 batterie en kWh ne compense pas un manque de puissance active (kW) ou apparente (kVA) du PCS.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-196e7bd6 auto-h3 elementor-widget elementor-widget-heading\" data-id=\"196e7bd6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Adapter la gestion thermique et l'architecture de s\u00e9curit\u00e9 au produit s\u00e9lectionn\u00e9<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-80be5795 auto-p elementor-widget elementor-widget-heading\" data-id=\"80be5795\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Le mod\u00e8le ESSA0100B-0215 utilise un refroidissement par air, l'Energon 261 utilise un refroidissement par liquide, et les syst\u00e8mes conteneuris\u00e9s ESSC utilisent un refroidissement par air \u00e0 temp\u00e9rature contr\u00f4l\u00e9e.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-de3cfdf3 auto-p elementor-widget elementor-widget-heading\" data-id=\"de3cfdf3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Le mod\u00e8le ESSC0500B-1075 offre <strong>500 kW \/ 1,0752 MWh<\/strong>, tandis que l'ESSC1000B-2150 offre <strong>1 MW \/ 2,1504 MWh<\/strong>.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7ac08957 auto-p elementor-widget elementor-widget-heading\" data-id=\"7ac08957\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Le projet peut s\u2019appuyer sur les r\u00e9f\u00e9rentiels IEC 62619, UL 9540, UL 9540A et NFPA 855 selon les exigences applicables au march\u00e9 de destination et celles de l\u2019autorit\u00e9 comp\u00e9tente.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-20c1f644 elementor-tablet-align-center elementor-align-center auto-cta elementor-widget elementor-widget-button\" data-id=\"20c1f644\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"#elementor-action%3Aaction%3Dpopup%3Aopen%26settings%3DeyJpZCI6Ijk0OCIsInRvZ2dsZSI6ZmFsc2V9\" target=\"_blank\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Dimensionner le soutien de pointe de mon usine de moulage<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-58b10724 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"58b10724\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">\u00c9tablir l'analyse de rentabilit\u00e9 \u00e0 partir du tarif r\u00e9el et du co\u00fbt de la mise \u00e0 niveau<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-01a8d291 auto-p elementor-widget elementor-widget-heading\" data-id=\"01a8d291\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">L'analyse financi\u00e8re devrait commencer par le pic de facturation et le tarif r\u00e9el.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f0823523 auto-h3 elementor-widget elementor-widget-heading\" data-id=\"f0823523\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Calculer les \u00e9conomies sur les frais de puissance \u00e0 partir de la pointe mesur\u00e9e au compteur<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c7212650 auto-p elementor-widget elementor-widget-heading\" data-id=\"c7212650\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Si une usine r\u00e9duit de 300 kW une pointe de puissance factur\u00e9e de 500 kW, \u00e0 un tarif de puissance de 20 $\/kW, le calcul donne :<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-053e865b elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"053e865b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>Mensuel :<\/strong> 300 kW \u00d7 20 $\/kW = <strong>$6,000<\/strong><\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>Douze p\u00e9riodes de facturation comparables :<\/strong> 6 000 $ \u00d7 12 = <strong>72 000 $ par an<\/strong><\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-216d581b auto-p elementor-widget elementor-widget-heading\" data-id=\"216d581b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Les 72 000 $ correspondent uniquement aux \u00e9conomies sur les frais de puissance. Chiffrez s\u00e9par\u00e9ment les p\u00e9nalit\u00e9s de d\u00e9passement \u00e9vit\u00e9es ou l\u2019\u00e9ventuel report des travaux de renforcement du r\u00e9seau, lorsqu\u2019ils s\u2019appliquent, en utilisant le tarif et l\u2019intervalle de mesure r\u00e9els.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-cedcb702 auto-h3 elementor-widget elementor-widget-heading\" data-id=\"cedcb702\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Appliquer les mesures incitatives une fois le dimensionnement du syst\u00e8me \u00e9lectrique effectu\u00e9<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7ba5cdd0 auto-p elementor-widget elementor-widget-heading\" data-id=\"7ba5cdd0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Les projets admissibles aux \u00c9tats-Unis peuvent int\u00e9grer au mod\u00e8le financier le cr\u00e9dit d\u2019imp\u00f4t \u00e0 l\u2019investissement dans l\u2019\u00e9lectricit\u00e9 propre pr\u00e9vu \u00e0 la section 48E ainsi qu\u2019un amortissement acc\u00e9l\u00e9r\u00e9. Avant d\u2019int\u00e9grer un avantage fiscal \u00e0 la d\u00e9cision d\u2019investissement, confirmez avec le conseiller fiscal du projet l\u2019admissibilit\u00e9, les exigences concernant les \u00e9quipements et la cha\u00eene d\u2019approvisionnement, ainsi que les dates pertinentes du projet. Un devis de MegSolid ne suffit pas \u00e0 \u00e9tablir l\u2019admissibilit\u00e9 au cr\u00e9dit d\u2019imp\u00f4t.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-609e4b31 auto-p elementor-widget elementor-widget-heading\" data-id=\"609e4b31\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\"><strong>S\u00e9quence financi\u00e8re :<\/strong> d\u00e9passement de puissance \u2192 puissance du PCS \u2192 capacit\u00e9 \u00e9nerg\u00e9tique de la batterie \u2192 co\u00fbt de l\u2019installation \u2192 \u00e9conomies d\u2019exploitation \u2192 aides.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7897e86c auto-p elementor-widget elementor-widget-heading\" data-id=\"7897e86c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Cette d\u00e9cision \u00e9vite que le mod\u00e8le financier ne conduise l'usine \u00e0 opter pour une batterie surdimensionn\u00e9e.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f4755364 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"f4755364\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">N\u2019ajouter des services secondaires qu\u2019apr\u00e8s avoir r\u00e9serv\u00e9 l\u2019\u00e9tat de charge n\u00e9cessaire \u00e0 l\u2019\u00e9cr\u00eatage<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-fb4e0fb8 auto-p elementor-widget elementor-widget-heading\" data-id=\"fb4e0fb8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">L\u2019\u00e9cr\u00eatage reste la priorit\u00e9. Le secours et le photovolta\u00efque devraient le compl\u00e9ter tout en pr\u00e9servant la puissance et la r\u00e9serve d\u2019\u00e9tat de charge n\u00e9cessaires pour respecter la limite de soutirage.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-11c82826 auto-h3 elementor-widget elementor-widget-heading\" data-id=\"11c82826\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Qualit\u00e9 de l\u2019\u00e9lectricit\u00e9 et protection contre les microcoupures<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-854f6ddf auto-p elementor-widget elementor-widget-heading\" data-id=\"854f6ddf\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">De br\u00e8ves coupures de courant peuvent perturber le fonctionnement des automates programmables, des pompes, des syst\u00e8mes de refroidissement, des syst\u00e8mes de manutention et des syst\u00e8mes de contr\u00f4le des processus, entra\u00eenant ainsi des temps d'arr\u00eat bien plus longs que la perturbation elle-m\u00eame.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ed849c1b auto-p elementor-widget elementor-widget-heading\" data-id=\"ed849c1b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">L\u2019alimentation de secours n\u00e9cessite une s\u00e9paration volontaire du r\u00e9seau public, des \u00e9quipements de transfert, un jeu de barres d\u00e9di\u00e9 aux charges prot\u00e9g\u00e9es, un mode de fonctionnement adapt\u00e9 du PCS, une puissance apparente suffisante en kVA et une r\u00e9serve d\u2019\u00e9tat de charge.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c3515f63 auto-p elementor-widget elementor-widget-heading\" data-id=\"c3515f63\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default translation-block\">Maintenir les commandes, le refroidissement et les charges n\u00e9cessaires \u00e0 un arr\u00eat contr\u00f4l\u00e9 peut \u00eatre plus efficace que de secourir chaque presse \u00e0 injecter. Le <a href=\"https:\/\/www.solidess.com\/fr\/systeme-de-secours-a-batterie-raccorde-au-reseau-pourquoi-le-systeme-bess-se-met-hors-tension-en-cas-de-coupure-de-courant\/\" style=\"color:#61ce70\" target=\"_self\">guide de MegSolid sur les coupures avec un BESS raccord\u00e9 au r\u00e9seau<\/a> explique cette limite.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a0131c0e auto-h3 elementor-widget elementor-widget-heading\" data-id=\"a0131c0e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Synergies avec les installations solaires sur toiture<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-50a403c3 auto-p elementor-widget elementor-widget-heading\" data-id=\"50a403c3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Les installations photovolta\u00efques sur toiture permettent de r\u00e9duire les pr\u00e9l\u00e8vements sur le r\u00e9seau pendant la journ\u00e9e, tandis que le syst\u00e8me de stockage d'\u00e9nergie par batterie (BESS) stocke la production exc\u00e9dentaire ou conserve l'\u00e9nergie en vue des pics de production.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6e844fe4 auto-p elementor-widget elementor-widget-heading\" data-id=\"6e844fe4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default translation-block\">La recharge solaire ne doit pas faire d\u00e9passer la limite contractuelle au point de couplage commun (PCC), et le BESS doit rester dimensionn\u00e9 d\u2019apr\u00e8s le d\u00e9ficit r\u00e9el de puissance. La <a href=\"https:\/\/www.solidess.com\/fr\/comment-specifier-un-controle-de-zero-injection-au-pcc-pour-un-systeme-de-stockage-denergie-par-batterie-bess\/\" style=\"color:#61ce70\" target=\"_self\">commande z\u00e9ro injection au PCC<\/a> peut coordonner le photovolta\u00efque et la batterie lorsque l\u2019injection dans le r\u00e9seau est limit\u00e9e.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-50ef23e1 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"50ef23e1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Adapter la plateforme MegSolid au d\u00e9ficit de capacit\u00e9s constat\u00e9<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-440c2906 auto-image elementor-widget elementor-widget-image\" data-id=\"440c2906\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"1448\" height=\"1086\" src=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Injection-Molding-MegSolid-Product-Route-Decision.jpg\" class=\"attachment-1536x1536 size-1536x1536 wp-image-5538\" alt=\"\u00c9tude technique sur la r\u00e9duction des pics de puissance dans le moulage par injection, pr\u00e9sentant la s\u00e9quence de dimensionnement, la r\u00e9gulation PCC, la cha\u00eene de commande de r\u00e9duction des pics, la puissance en fonction de l&#039;\u00e9nergie de l&#039;\u00e9v\u00e9nement et un exemple de tampon de capacit\u00e9 temporaire de 80 kW\" srcset=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Injection-Molding-MegSolid-Product-Route-Decision.jpg 1448w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Injection-Molding-MegSolid-Product-Route-Decision-300x225.jpg 300w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Injection-Molding-MegSolid-Product-Route-Decision-1024x768.jpg 1024w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Injection-Molding-MegSolid-Product-Route-Decision-768x576.jpg 768w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Injection-Molding-MegSolid-Product-Route-Decision-16x12.jpg 16w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/09\/Injection-Molding-MegSolid-Product-Route-Decision-600x450.jpg 600w\" sizes=\"(max-width: 1448px) 100vw, 1448px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f3de1921 auto-p elementor-widget elementor-widget-heading\" data-id=\"f3de1921\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Les usines de moulage par injection plastique ne devraient pas continuer \u00e0 subir des p\u00e9nalit\u00e9s de capacit\u00e9 ni retarder l\u2019extension de leur parc de machines simplement parce que de brefs pics de production d\u00e9passent la limite du r\u00e9seau.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-873d2578 auto-p elementor-widget elementor-widget-heading\" data-id=\"873d2578\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\"><strong>Processus de d\u00e9termination de la taille :<\/strong> mesurer la puissance appel\u00e9e au PCC \u2192 relever la puissance souscrite \u2192 calculer le d\u00e9passement en kW ou en kVA \u2192 mesurer sa dur\u00e9e \u2192 v\u00e9rifier la possibilit\u00e9 de recharge \u2192 choisir le syst\u00e8me MegSolid.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-29fa5140 auto-h3 elementor-widget elementor-widget-heading\" data-id=\"29fa5140\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Choisir une gamme de produits selon la r\u00e9duction de pointe mesur\u00e9e<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4bcbfdd5 elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"4bcbfdd5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>Jusqu'\u00e0 100 kW :<\/strong> ESSA0100B-0215 si l\u2019\u00e9nergie utile permet de tenir toute la dur\u00e9e de la pointe.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>Capacit\u00e9 \u00e9nerg\u00e9tique sup\u00e9rieure au format armoire, puissance apparente de 125 kVA et refroidissement par liquide :<\/strong> Energon 261.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>Besoins de puissance de 150 \u00e0 500 kW \u00e0 dimensionner :<\/strong> MEGA PCS avec capacit\u00e9 \u00e9nerg\u00e9tique de la batterie dimensionn\u00e9e s\u00e9par\u00e9ment.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>Pics de puissance \u00e0 l'\u00e9chelle de l'usine compris entre 500 kW et 1 MW :<\/strong> Syst\u00e8mes en conteneurs ESSC.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f5d3dc51 auto-h3 elementor-widget elementor-widget-heading\" data-id=\"f5d3dc51\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Transmettre \u00e0 MegSolid les courbes de charge \u00e9lectrique de l\u2019usine<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7ba3b8fd auto-p elementor-widget elementor-widget-heading\" data-id=\"7ba3b8fd\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Transmettez les courbes de charge par intervalle, la puissance souscrite, la pointe au PCC, le facteur de puissance, les puissances nominales des machines, le calendrier de production, les ajouts pr\u00e9vus et le sch\u00e9ma unifilaire. Ces \u00e9l\u00e9ments servent \u00e0 d\u00e9finir la puissance du PCS, la capacit\u00e9 \u00e9nerg\u00e9tique de la batterie, la recharge et le choix de la gamme. Demandez \u00e0 MegSolid de proposer l\u2019\u00e9tage de puissance le plus petit qui couvre la pointe et de pr\u00e9ciser son \u00e9nergie utile en courant alternatif, les hypoth\u00e8ses de r\u00e9serve d\u2019\u00e9tat de charge et de recharge, le p\u00e9rim\u00e8tre de commande au PCC et la r\u00e9partition d\u00e9taill\u00e9e des responsabilit\u00e9s d\u2019installation et de mise en service. Comparez l\u2019offre compl\u00e8te aux frais de capacit\u00e9 r\u00e9ellement factur\u00e9s et au co\u00fbt de renforcement du r\u00e9seau propos\u00e9.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5428f55a elementor-tablet-align-center elementor-align-center auto-cta elementor-widget elementor-widget-button\" data-id=\"5428f55a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"#elementor-action%3Aaction%3Dpopup%3Aopen%26settings%3DeyJpZCI6Ijk0OCIsInRvZ2dsZSI6ZmFsc2V9\" target=\"_blank\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Envoyez votre profil de charge sur 15 minutes \u2014 Recevez gratuitement une analyse de la courbe de charge et un rapport sur le retour sur investissement (ROI) li\u00e9 au choix d\u2019un syst\u00e8me de stockage d\u2019\u00e9nergie par batterie (BESS)<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-050b0a88 auto-faq e-flex e-con-boxed e-con e-child\" data-id=\"050b0a88\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-6eb7b8d7 elementor-widget elementor-widget-heading\" data-id=\"6eb7b8d7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">FAQ<\/h2>\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-5d7d85bf e-con-full e-flex e-con e-child\" data-id=\"5d7d85bf\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-95db2bcf elementor-widget elementor-widget-n-accordion\" data-id=\"95db2bcf\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;default_state&quot;:&quot;all_collapsed&quot;,&quot;max_items_expended&quot;:&quot;one&quot;,&quot;n_accordion_animation_duration&quot;:{&quot;unit&quot;:&quot;ms&quot;,&quot;size&quot;:400,&quot;sizes&quot;:[]}}\" data-widget_type=\"nested-accordion.default\">\n\t\t\t\t\t\t\t<div class=\"e-n-accordion\" aria-label=\"Accord\u00e9on. Ouvrez les liens \u00e0 l&#039;aide de la touche Entr\u00e9e ou de la barre d&#039;espace, fermez-les avec la touche \u00c9chap et naviguez \u00e0 l&#039;aide des touches fl\u00e9ch\u00e9es.\">\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2510\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"1\" tabindex=\"0\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2510\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Le stockage par batteries peut-il r\u00e9duire les p\u00e9nalit\u00e9s de d\u00e9passement de puissance dans une usine de moulage par injection plastique ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2510\" class=\"elementor-element elementor-element-e1bc1b1c e-con-full e-flex e-con e-child\" data-id=\"e1bc1b1c\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2510\" class=\"elementor-element elementor-element-37515529 e-con-full e-flex e-con e-child\" data-id=\"37515529\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-9c78a7d9 elementor-widget elementor-widget-heading\" data-id=\"9c78a7d9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Oui. Un BESS pilot\u00e9 \u00e0 partir des mesures au point de couplage commun (PCC) peut maintenir la puissance soutir\u00e9e au r\u00e9seau sous la limite contractuelle s\u2019il est dimensionn\u00e9 pour compenser le d\u00e9passement mesur\u00e9.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2511\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"2\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2511\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Un syst\u00e8me de stockage d'\u00e9nergie par batterie (BESS) de 100 kW est-il suffisant pour une usine de moulage par injection ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2511\" class=\"elementor-element elementor-element-831be53a e-con-full e-flex e-con e-child\" data-id=\"831be53a\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2511\" class=\"elementor-element elementor-element-ccd9a73a e-con-full e-flex e-con e-child\" data-id=\"ccd9a73a\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-df8756e2 elementor-widget elementor-widget-heading\" data-id=\"df8756e2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Oui, si la r\u00e9duction de pointe n\u00e9cessaire est au plus de 100 kW et si l\u2019\u00e9nergie utile de la batterie permet de maintenir cette r\u00e9duction pendant toute la pointe.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2512\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"3\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2512\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Une usine de moulage par injection devrait-elle utiliser l'ESSA0100B-0215 ou l'Energon 261 ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2512\" class=\"elementor-element elementor-element-952237b2 e-con-full e-flex e-con e-child\" data-id=\"952237b2\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2512\" class=\"elementor-element elementor-element-35620f92 e-con-full e-flex e-con e-child\" data-id=\"35620f92\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-46425882 elementor-widget elementor-widget-heading\" data-id=\"46425882\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Choisissez l\u2019ESSA0100B-0215 pour \u00e9cr\u00eater une pointe jusqu\u2019\u00e0 100 kW. Choisissez l\u2019Energon 261 si le projet exige une capacit\u00e9 \u00e9nerg\u00e9tique sup\u00e9rieure au format armoire, une puissance apparente de sortie de 125 kVA en courant alternatif et un refroidissement par liquide.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2513\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"4\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2513\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Le stockage par batteries peut-il \u00e9viter un renforcement du transformateur ou du raccordement au r\u00e9seau ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2513\" class=\"elementor-element elementor-element-0f0095e8 e-con-full e-flex e-con e-child\" data-id=\"0f0095e8\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2513\" class=\"elementor-element elementor-element-0c6bca0d e-con-full e-flex e-con e-child\" data-id=\"0c6bca0d\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-4dc18aa3 elementor-widget elementor-widget-heading\" data-id=\"4dc18aa3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Oui, si le d\u00e9passement au PCC est de courte dur\u00e9e et que l\u2019installation ne manque pas de puissance en permanence.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2514\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"5\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2514\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> De quelles donn\u00e9es MegSolid a-t-il besoin pour dimensionner les syst\u00e8mes de stockage d'\u00e9nergie par batterie (BESS) destin\u00e9s aux presses \u00e0 injecter ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2514\" class=\"elementor-element elementor-element-019cca0b e-con-full e-flex e-con e-child\" data-id=\"019cca0b\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2514\" class=\"elementor-element elementor-element-3fc67037 e-con-full e-flex e-con e-child\" data-id=\"3fc67037\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-f2e6bc19 elementor-widget elementor-widget-heading\" data-id=\"f2e6bc19\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Transmettez les courbes de charge par intervalle, la puissance souscrite en kW ou en kVA, la pointe de puissance au point de couplage commun (PCC), le facteur de puissance, les puissances nominales des principales machines, le calendrier de production, les extensions pr\u00e9vues et le sch\u00e9ma unifilaire \u00e9lectrique.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>\u00c9liminez les p\u00e9nalit\u00e9s li\u00e9es \u00e0 la capacit\u00e9 et les pics de facturation li\u00e9s \u00e0 la consommation des machines de moulage par injection plastique gr\u00e2ce au syst\u00e8me de stockage par batterie MegSolid C&amp;I, dimensionn\u00e9 en fonction des valeurs r\u00e9elles de kW, kVA et des cycles de production de votre usine.<\/p>","protected":false},"author":4,"featured_media":5537,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"_joinchat":[],"footnotes":""},"categories":[1,714],"tags":[715,718,721,717,298,720,719,688,716],"class_list":["post-5540","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-bess","category-ci-battery-storage-solutions","tag-ci-battery-storage-for-plastic-injection-molding-machines","tag-capacity-fines-bess","tag-essc-containerized-bess","tag-injection-molding-peak-shaving","tag-mega-pcs","tag-megsolid-energon-261","tag-megsolid-essa0100b-0215","tag-pcc-peak-shaving","tag-plastic-injection-molding-battery-storage"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/posts\/5540","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/comments?post=5540"}],"version-history":[{"count":7,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/posts\/5540\/revisions"}],"predecessor-version":[{"id":6430,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/posts\/5540\/revisions\/6430"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/media\/5537"}],"wp:attachment":[{"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/media?parent=5540"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/categories?post=5540"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/tags?post=5540"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}