{"id":7748,"date":"2026-10-31T16:43:49","date_gmt":"2026-10-31T08:43:49","guid":{"rendered":"https:\/\/www.solidess.com\/?p=7748"},"modified":"2026-10-31T16:43:49","modified_gmt":"2026-10-31T08:43:49","slug":"lifepo4-48v-battery-voltage-chart-charging-guide","status":"publish","type":"post","link":"https:\/\/www.solidess.com\/fr\/lifepo4-48v-battery-voltage-chart-charging-guide\/","title":{"rendered":"Tableau des plages de tension des batteries LiFePO4 et semi-solides : 48 V (51,2 V) \u2013 Guide sur l'\u00e9tat de charge et la recharge solaire"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"7748\" class=\"elementor elementor-7748\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-bf4793c e-con-full auto-article-root e-flex e-con e-parent\" data-id=\"bf4793c\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-44c485b7 auto-p elementor-widget elementor-widget-heading\" data-id=\"44c485b7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Les cellules LiFePO4 \u00e0 tension nominale standard de 3,2 V et les cellules LFP semi-solides ont une <strong>Plage de tension du LiFePO4<\/strong> de <strong>De 2,50 V (0 % de niveau de charge) \u00e0 3,65 V (100 % de charge compl\u00e8te)<\/strong>. Pour un parc de batteries solaires de 16S 48 V (51,2 V nominaux), la plage de tension de fonctionnement est de <strong>40,0 V \u00e0 58,4 V<\/strong>, avec une tension de charge solaire quotidienne recommand\u00e9e pour la charge de masse\/d'absorption comprise entre 56,0 V et 56,8 V (3,50 V\u20133,55 V par cellule) et une tension de maintien comprise entre 53,6 V et 54,0 V (3,35 V\u20133,38 V par cellule).<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-89a87589 auto-p elementor-widget elementor-widget-heading\" data-id=\"89a87589\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Les tableaux ci-dessous indiquent les tensions de l'\u00e9tat de charge (SoC) au repos et les points de consigne de charge MPPT manuelle pour des cellules de 3,2 V, des batteries de 12 V (4S), 24 V (8S), 15S (48,0 V) et 16S (51,2 V).<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6b4173e0 auto-image elementor-widget elementor-widget-image\" data-id=\"6b4173e0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"1536\" height=\"805\" src=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/10\/lifepo4-51.2v-soc-discharge-curve-1536x805.webp\" class=\"attachment-1536x1536 size-1536x1536 wp-image-7746\" alt=\"Courbe de tension de repos du LiFePO4 16S 51,2 V en fonction du pourcentage de charge (SoC), indiquant une tension de 54,4 V \u00e0 100 % de repos, un plateau compris entre 51,5 et 53,1 V pour un SoC compris entre 30 et 80 %, et un pic de charge distinct compris entre 57,6 et 58,4 V\" srcset=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/10\/lifepo4-51.2v-soc-discharge-curve-1536x805.webp 1536w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/10\/lifepo4-51.2v-soc-discharge-curve-300x157.webp 300w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/10\/lifepo4-51.2v-soc-discharge-curve-1024x537.webp 1024w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/10\/lifepo4-51.2v-soc-discharge-curve-768x403.webp 768w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/10\/lifepo4-51.2v-soc-discharge-curve-18x9.webp 18w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/10\/lifepo4-51.2v-soc-discharge-curve-600x315.webp 600w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/10\/lifepo4-51.2v-soc-discharge-curve.webp 1984w\" sizes=\"(max-width: 1536px) 100vw, 1536px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-21207938 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"21207938\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Tableau complet de la plage de tension et de l'\u00e9tat de charge (SoC) des batteries LiFePO4 (3,2 V \/ 12 V \/ 24 V \/ 48 V \/ 51,2 V)<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-819bbc70 auto-h3 elementor-widget elementor-widget-heading\" data-id=\"819bbc70\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Tension en circuit ouvert au repos par rapport \u00e0 la tension sous charge<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-aa1dc793 auto-p elementor-widget elementor-widget-heading\" data-id=\"aa1dc793\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Les valeurs indiqu\u00e9es dans le tableau 1 correspondent \u00e0 la tension en circuit ouvert au repos (OCV), mesur\u00e9e apr\u00e8s que la batterie a \u00e9t\u00e9 d\u00e9connect\u00e9e de toutes les sources de charge et des charges de l'onduleur pendant au moins 30 minutes \u00e0 25 \u00b0C (77 \u00b0F).<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4014a128 auto-p elementor-widget elementor-widget-heading\" data-id=\"4014a128\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Lorsqu'une batterie est en cours de charge, la tension aux bornes est sup\u00e9rieure de 0,5 V \u00e0 2,0 V \u00e0 la tension en circuit ouvert (OCV) au repos, en fonction du courant de charge. \u00c0 l'inverse, lors de l'alimentation de charges CA importantes, la tension aux bornes chute en dessous de la tension ouverte en repos (OCV) en raison de l'imp\u00e9dance interne des cellules ($V_{\\text{chute}} = I \\times R_{\\text{interne}}$).<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b5802bb7 auto-h3 elementor-widget elementor-widget-heading\" data-id=\"b5802bb7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">15S (48,0 V) vs 16S (51,2 V) : v\u00e9rifiez d'abord le nombre de cellules<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ea439ff1 auto-p elementor-widget elementor-widget-heading\" data-id=\"ea439ff1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Sur le march\u00e9 de l'\u00e9nergie solaire et des t\u00e9l\u00e9communications en 48 V, deux configurations en s\u00e9rie coexistent sous l'appellation \" 48 V \" :<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6ac223a2 elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"6ac223a2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">15S (15 cellules en s\u00e9rie, tension nominale de 48,0 V) : couramment utilis\u00e9 dans les baies de t\u00e9l\u00e9communications anciennes et dans certaines batteries de baies de serveurs sp\u00e9cifiques \u00e0 certaines marques. La tension de charge maximale est de 54,75 V ($3,65\\text{V} \\times 15$).<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">16S (16 cellules en s\u00e9rie, tension nominale de 51,2 V) : configuration standard pour les batteries solaires r\u00e9sidentielles murales, mobiles et destin\u00e9es aux baies de serveurs, notamment <strong><a href=\"https:\/\/www.solidess.com\/fr\/\" target=\"_blank\" style=\"color:#61ce70\">MegSolid<\/a><\/strong>'de la gamme de batteries 51,2 V 314 Ah. La tension maximale indiqu\u00e9e dans la fiche technique est de 58,4 V ($3,65\\text{V} \\times 16$).<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-033cb9bd auto-p elementor-widget elementor-widget-heading\" data-id=\"033cb9bd\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">V\u00e9rifiez sur la plaque signal\u00e9tique si votre pack est de type 15S ou 16S avant de configurer les param\u00e8tres MPPT. L'application de tensions de charge 16S (56,0 V\u201358,4 V) \u00e0 une batterie 15S d\u00e9clenche son BMS via la protection contre les surtensions (OVP), tandis que l'application des param\u00e8tres 15S (52,5 V\u201354,0 V) \u00e0 un pack 16S entra\u00eene une sous-charge de celui-ci.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3fe39161 auto-h3 elementor-widget elementor-widget-heading\" data-id=\"3fe39161\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Tableau 1 : Tableau des tensions au repos et \u00e0 l'\u00e9tat de charge (SoC) semi-solide pour les batteries LiFePO4<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b4cf1ab0 auto-table elementor-widget elementor-widget-text-editor\" data-id=\"b4cf1ab0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"cea-table-wrap\"><table><thead><tr><th>\u00c9tat de charge (SoC)<\/th><th>Une seule cellule (3,2 V)<\/th><th>Batterie 12 V (4S \/ 12,8 V)<\/th><th>Batterie 24 V (8S \/ 25,6 V)<\/th><th>Batterie 48 V (15S \/ 48,0 V)<\/th><th>Pack solaire 48 V (16S \/ 51,2 V)<\/th><th>Zone op\u00e9rationnelle<\/th><\/tr><\/thead><tbody><tr><td>100 % (pic de charge)<\/td><td>3,60 V \u2013 3,65 V<\/td><td>14,4 V \u2013 14,6 V<\/td><td>28,8 V \u2013 29,2 V<\/td><td>54,0 V \u2013 54,75 V<\/td><td>57,6 V \u2013 58,4 V<\/td><td>Haut du genou (r\u00e9\u00e9quilibrage cellulaire)<\/td><\/tr><tr><td>100 % (30 min de repos)<\/td><td>3,40 V<\/td><td>13,6 V<\/td><td>27,2 V<\/td><td>51,0 V<\/td><td>54,4 V<\/td><td>V\u00e9ritablement repos\u00e9, en pleine forme<\/td><\/tr><tr><td>90 % de l'\u00e9tat de charge (SoC)<\/td><td>3,35 V<\/td><td>13,4 V<\/td><td>26,8 V<\/td><td>50,25 V<\/td><td>53,6 V<\/td><td>D\u00e9part sur plateau plat<\/td><\/tr><tr><td>80 % de charge de la batterie<\/td><td>3,32 V<\/td><td>13,28 V<\/td><td>26,56 V<\/td><td>49,8 V<\/td><td>53,1 V<\/td><td>Le v\u00e9lo au quotidien : comment en tirer le meilleur parti<\/td><\/tr><tr><td>70 % de charge de la batterie<\/td><td>3,30 V<\/td><td>13,20 V<\/td><td>26,40 V<\/td><td>49,5 V<\/td><td>52,8 V<\/td><td>Plateau plat<\/td><\/tr><tr><td>60 % de charge de la batterie<\/td><td>3,27 V<\/td><td>13,08 V<\/td><td>26,16 V<\/td><td>49,05 V<\/td><td>52,3 V<\/td><td>Plateau plat<\/td><\/tr><tr><td>50 % de l'\u00e9tat de charge (SoC)<\/td><td>3,26 V<\/td><td>13,04 V<\/td><td>26,08 V<\/td><td>48,9 V<\/td><td>52,2 V<\/td><td>Valeur nominale m\u00e9diane<\/td><\/tr><tr><td>40 % de charge de la batterie<\/td><td>3,25 V<\/td><td>13,00 V<\/td><td>26,00 V<\/td><td>48,75 V<\/td><td>52,0 V<\/td><td>Plateau plat<\/td><\/tr><tr><td>30 % de charge de la batterie<\/td><td>3,22 V<\/td><td>12,88 V<\/td><td>25,76 V<\/td><td>48,3 V<\/td><td>51,5 V<\/td><td>Extr\u00e9mit\u00e9 plate du plateau<\/td><\/tr><tr><td>20 % de l'\u00e9tat de charge (SoC)<\/td><td>3,20 V<\/td><td>12,80 V<\/td><td>25,60 V<\/td><td>48,0 V<\/td><td>51,2 V<\/td><td>Recharge recommand\u00e9e du r\u00e9seau\/du g\u00e9n\u00e9rateur<\/td><\/tr><tr><td>10 % de l'\u00e9tat de charge (SoC)<\/td><td>3,00 V<\/td><td>12,00 V<\/td><td>24,00 V<\/td><td>45,0 V<\/td><td>48,0 V<\/td><td>Bas du genou (chute rapide)<\/td><\/tr><tr><td>0 % (seuil BMS)<\/td><td>2,50 V<\/td><td>10,00 V<\/td><td>20,00 V<\/td><td>37,5 V<\/td><td>40,0 V<\/td><td>Verrouillage en cas de sous-tension du BMS \u00ab dur \u00bb<\/td><\/tr><\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-34994ab5 auto-p elementor-widget elementor-widget-heading\" data-id=\"34994ab5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\"><em>Vous souhaitez cr\u00e9er ou agrandir une banque de sauvegarde 16S chez vous ? D\u00e9couvrez notre <strong><a href=\"https:\/\/www.solidess.com\/fr\/piles\/stockage-denergie-residentiel\/\" target=\"_blank\" style=\"color:#61ce70\">Batteries solaires r\u00e9sidentielles 16S 51,2 V<\/a><\/strong> d'une capacit\u00e9 comprise entre 16 kWh et 96 kWh.<\/em><\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e299c13d auto-h2 elementor-widget elementor-widget-heading\" data-id=\"e299c13d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Comprendre la courbe de tension plate et pourquoi les batteries LFP semi-solides offrent de meilleures performances<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d4e1477e auto-h3 elementor-widget elementor-widget-heading\" data-id=\"d4e1477e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Le plateau de tension compris entre 30 % et 80 %<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ce238abf auto-p elementor-widget elementor-widget-heading\" data-id=\"ce238abf\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Contrairement aux batteries au plomb ou aux batteries lithium-ion NMC, dont la tension diminue progressivement de l'\u00e9tat charg\u00e9 \u00e0 l'\u00e9tat d\u00e9charg\u00e9, les batteries au lithium-fer-phosphate pr\u00e9sentent une r\u00e9action \u00e9lectrochimique en deux phases qui g\u00e9n\u00e8re une courbe de d\u00e9charge plate entre 30 % et 80 % de l'\u00e9tat de charge (SoC).<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-da97a678 auto-p elementor-widget elementor-widget-heading\" data-id=\"da97a678\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Dans la colonne 16S (51,2 V) du tableau 1, la tension au repos comprise entre 80 % de SoC (53,1 V) et 30 % de SoC (51,5 V) ne varie que de 1,6 V sur l'ensemble du pack (0,10 V par cellule). \u00c9tant donn\u00e9 qu\u2019un courant de charge modeste ou une variation de la temp\u00e9rature ambiante fait varier la tension aux bornes de 0,5 V \u00e0 1,0 V, un onduleur fonctionnant en mode de tension de base pour batteries au plomb-acide ne peut pas lire de mani\u00e8re fiable l\u2019\u00e9tat de charge (SoC) des batteries LiFePO\u2084 dans la plage interm\u00e9diaire de SoC. Un suivi pr\u00e9cis de l\u2019\u00e9tat de charge n\u00e9cessite un syst\u00e8me de gestion de batterie (BMS) qui compte les coulombs (en int\u00e9grant le courant en fonction du temps, $\\int I , dt$) et se recalibre lorsque le pack atteint le point d\u2019inflexion sup\u00e9rieur de la tension.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a6038cd2 auto-h3 elementor-widget elementor-widget-heading\" data-id=\"a6038cd2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">LiFePO4 liquide standard vs LFP hybride \u00e0 l'\u00e9tat solide de 51,2 V<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-36f7ff55 auto-p elementor-widget elementor-widget-heading\" data-id=\"36f7ff55\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Les batteries LFP \u00e0 \u00e9lectrolyte liquide classiques se heurtent souvent \u00e0 deux contraintes pratiques : une chute de tension aux bornes lors des d\u00e9marrages de moteurs \u00e0 fort courant d'appel, et des exigences plus strictes en mati\u00e8re de s\u00e9curit\u00e9 incendie en int\u00e9rieur.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2fd0eb99 auto-p elementor-widget elementor-widget-heading\" data-id=\"2fd0eb99\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">MegSolid's <strong><a href=\"https:\/\/www.solidess.com\/fr\/product\/batterie-de-stockage-denergie-solide-megsold\/\" target=\"_blank\" style=\"color:#61ce70\">MEGA-512314FL1 Batterie hybride \u00e0 semi-conducteurs de 51,2 V et 314 Ah (16,07 kWh)<\/a><\/strong> r\u00e9pond \u00e0 ces deux enjeux gr\u00e2ce \u00e0 la conception de ses cellules semi-solides LiFePO\u2084 :<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f50155c7 auto-p elementor-widget elementor-widget-heading\" data-id=\"f50155c7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\"><ol><li>Faible imp\u00e9dance interne ($\\le 15\\text{ m}\\Omega$) et intensit\u00e9 nominale continue de 200 A : le d\u00e9marrage d\u2019une pompe de puits submersible de 240 V, d\u2019un compresseur de climatiseur ou d\u2019un moteur d\u2019atelier entra\u00eene un courant d\u2019appel bref de 3 \u00e0 6 fois sup\u00e9rieur \u00e0 l\u2019intensit\u00e9 nominale de l\u2019onduleur. Sur les batteries \u00e0 haute r\u00e9sistance, cette surtension fait chuter la tension aux bornes en dessous du seuil de coupure basse tension de l\u2019onduleur (par exemple, 48,0 V), m\u00eame \u00e0 30 % de l\u2019\u00e9tat de charge (SoC). Avec une imp\u00e9dance interne $\\le 15\\text{ m}\\Omega$ et une capacit\u00e9 nominale de charge\/d\u00e9charge en continu de 200 A (plus de 10 kW \u00e0 partir d\u2019une seule unit\u00e9 de 16,07 kWh), l\u2019interface des cellules semi-solides maintient la tension aux bornes stable lors des d\u00e9marrages de moteur.<\/li><li>Dur\u00e9e de vie de 8 000 cycles et stabilit\u00e9 thermique : l'immobilisation de l'\u00e9lectrolyte dans une matrice semi-solide emp\u00eache les fuites de liquide, r\u00e9duit le risque d'emballement thermique et permet d'atteindre 8 000 cycles \u00e0 80 % de profondeur de d\u00e9charge (DoD) dans une plage de fonctionnement comprise entre 43,2 V et 57,6 V.<\/li><\/ol><\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1bf2ce41 auto-p elementor-widget elementor-widget-heading\" data-id=\"1bf2ce41\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Pour les installations r\u00e9sidentielles et commerciales de petite envergure n\u00e9cessitant une capacit\u00e9 \u00e9lev\u00e9e de protection contre les surtensions, consultez notre gamme compl\u00e8te de <strong><a href=\"https:\/\/www.solidess.com\/fr\/piles\/stockage-denergie-residentiel\/\" target=\"_blank\" style=\"color:#61ce70\">Batteries semi-solides de 48 V (51,2 V) destin\u00e9es au stockage d'\u00e9nergie domestique<\/a><\/strong>.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-35ea34f7 elementor-tablet-align-center elementor-align-center auto-cta elementor-widget elementor-widget-button\" data-id=\"35ea34f7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"#elementor-action%3Aaction%3Dpopup%3Aopen%26settings%3DeyJpZCI6Ijk0OCIsInRvZ2dsZSI6ZmFsc2V9\" target=\"_blank\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Contacter MegSolid | V\u00e9rifier la compatibilit\u00e9 de la batterie 51,2 V et de l'onduleur<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ee69478b auto-h2 elementor-widget elementor-widget-heading\" data-id=\"ee69478b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">R\u00e9glages de la tension de charge du LiFePO4 : explication des phases de charge rapide, d'absorption et d'entretien<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6d7dfe28 auto-h3 elementor-widget elementor-widget-heading\" data-id=\"6d7dfe28\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Pourquoi la charge solaire quotidienne vise une tension comprise entre 3,50 V et 3,55 V par cellule plut\u00f4t que 3,65 V ?<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-dd6f143a auto-p elementor-widget elementor-widget-heading\" data-id=\"dd6f143a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Les fiches techniques des cellules indiquent une tension maximale de 3,65 V par cellule (58,4 V pour un pack 16S). Lors des installations sur site, les ing\u00e9nieurs solaires programment quotidiennement la tension de charge (Bulk) \/ Absorption \u00e0 des valeurs inf\u00e9rieures, comprises entre 56,0 V et 56,8 V (3,50 V \u00e0 3,55 V par cellule), ou jusqu\u2019\u00e0 la valeur nominale de 57,6 V (3,60 V par cellule) indiqu\u00e9e dans la fiche technique du MEGA-512314FL1.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f0190d3b auto-p elementor-widget elementor-widget-heading\" data-id=\"f0190d3b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">En fixant la tension d'absorption quotidienne entre 3,50 V et 3,55 V par cellule, on \u00e9vite deux probl\u00e8mes courants :<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a19d581b elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"a19d581b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">D\u00e9clenchements intempestifs de la protection contre les surtensions des cellules (COVP) du BMS : les cellules LiFePO\u2084 atteignent environ 99 % de leur \u00e9tat de charge entre 3,45 V et 3,50 V. Au-del\u00e0 de 3,50 V, la tension des cellules augmente fortement. Comme les cellules mont\u00e9es en s\u00e9rie n\u2019ont jamais une r\u00e9sistance interne ni un \u00e9tat de charge identiques, le fait de pousser un pack 16S \u00e0 58,4 V fait souvent passer la cellule la plus charg\u00e9e au-del\u00e0 de 3,65 V, tandis que les 15 autres cellules restent proches de 3,58 V. Lorsque cette cellule d\u00e9passe 3,65 V, le BMS ouvre ses MOSFET de charge, ce qui provoque un pic de tension sur le bus MPPT et d\u00e9clenche un d\u00e9faut de l\u2019onduleur.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">R\u00e9duction de la dur\u00e9e d'\u00e9quilibrage et de la contrainte sur la cathode : Le fait de maintenir l'absorption entre 56,0 V et 56,8 V pendant 15 \u00e0 30 minutes permet de garder les 16 cellules dans la partie sup\u00e9rieure de la courbe suffisamment longtemps pour que le syst\u00e8me d'\u00e9quilibrage du BMS puisse \u00e9galiser les tensions des cellules sans se d\u00e9clencher, ce qui permet d'atteindre 6 000 \u00e0 plus de 8 000 cycles.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e8707de0 auto-h3 elementor-widget elementor-widget-heading\" data-id=\"e8707de0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Tableau 2 : R\u00e9glages recommand\u00e9s pour la tension de charge du LiFePO4 (onduleur manuel \/ mode MPPT)<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-64480a79 auto-table elementor-widget elementor-widget-text-editor\" data-id=\"64480a79\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"cea-table-wrap\"><table><thead><tr><th>Param\u00e8tres de recharge<\/th><th>Une seule cellule (3,2 V)<\/th><th>Syst\u00e8me 12 V (4S)<\/th><th>Syst\u00e8me 24 V (8S)<\/th><th>Syst\u00e8me 48 V (15S)<\/th><th>Syst\u00e8me solaire 48 V \/ 51,2 V (16S)<\/th><\/tr><\/thead><tbody><tr><td>Tension de masse \/ d'absorption (valeur maximale selon la fiche technique)<\/td><td>3,65 V<\/td><td>14,6 V<\/td><td>29,2 V<\/td><td>54,7 V<\/td><td>57,6 V \u2013 58,4 V<\/td><\/tr><tr><td>Apport global \/ Absorption (apport quotidien recommand\u00e9)<\/td><td>3,50 V \u2013 3,55 V<\/td><td>14,0 V \u2013 14,2 V<\/td><td>28,0 V \u2013 28,4 V<\/td><td>52,5 V \u2013 53,2 V<\/td><td>56,0 V \u2013 56,8 V<\/td><\/tr><tr><td>Tension de flottement<\/td><td>3,35 V \u2013 3,38 V<\/td><td>13,4 V \u2013 13,5 V<\/td><td>26,8 V \u2013 27,0 V<\/td><td>50,2 V \u2013 50,7 V<\/td><td>53,6 V \u2013 54,0 V<\/td><\/tr><tr><td>Tension d'\u00e9galisation<\/td><td>D\u00c9SACTIVER (D\u00e9sactiv\u00e9)<\/td><td>D\u00c9SACTIVER (0 V)<\/td><td>D\u00c9SACTIVER (0 V)<\/td><td>D\u00c9SACTIVER (0 V)<\/td><td>D\u00c9SACTIVER (Ne jamais \u00e9galiser le LFP)<\/td><\/tr><tr><td>Temps d'absorption \/ Courant r\u00e9siduel<\/td><td>15 \u00e0 30 minutes (0,05 $C$)<\/td><td>15 \u00e0 30 minutes<\/td><td>15 \u00e0 30 minutes<\/td><td>15 \u00e0 30 minutes<\/td><td>15 \u00e0 30 minutes (ou une queue de 2A \u00e0 5A)<\/td><\/tr><tr><td>Compensation de temp\u00e9rature<\/td><td>$0\\text{ mV}\/^\\circ\\text{C}$ (d\u00e9sactiv\u00e9)<\/td><td>$0\\text{ mV}\/^\\circ\\text{C}$<\/td><td>$0\\text{ mV}\/^\\circ\\text{C}$<\/td><td>$0\\text{ mV}\/^\\circ\\text{C}$<\/td><td>$0\\text{ mV}\/^\\circ\\text{C}$ (D\u00e9sactiver)<\/td><\/tr><tr><td>Seuil de coupure de basse tension recommand\u00e9 (onduleur)<\/td><td>3,00 V \u2013 3,10 V<\/td><td>12,0 V \u2013 12,4 V<\/td><td>24,0 V \u2013 24,8 V<\/td><td>45,0 V \u2013 46,5 V<\/td><td>48,0 V \u2013 49,6 V (10 %\u201315 % de niveau de charge)<\/td><\/tr><\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-99b5e216 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"99b5e216\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Recharge des batteries \u00e0 l'\u00e9nergie solaire : configuration de votre onduleur hybride 48 V et de votre MPPT<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d61b0280 auto-h3 elementor-widget elementor-widget-heading\" data-id=\"d61b0280\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Profil de charge solaire CC\/CV en deux phases (+ maintien en charge solaire)<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7ed32a1a auto-p elementor-widget elementor-widget-heading\" data-id=\"7ed32a1a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Lors de la recharge de batteries \u00e0 l'\u00e9nergie solaire via un onduleur hybride de 48 V ou un r\u00e9gulateur MPPT autonome, le chargeur effectue un cycle \u00e0 courant constant \/ tension constante (CC\/CV) :<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e38e2662 auto-p elementor-widget elementor-widget-heading\" data-id=\"e38e2662\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\"><ol><li>\u00c9tape 1 (charge en masse \/ courant constant) : du matin jusqu\u2019\u00e0 midi, le MPPT solaire fournit le courant maximal disponible (de 0,2 C \u00e0 0,5 C, soit de 60 A\u00e0 150 A pour un pack de 314 Ah, dans la limite de l'intensit\u00e9 nominale de 200 A du MEGA-512314FL1) jusqu'\u00e0 ce que la tension aux bornes atteigne le point de consigne d'absorption (56,0 V \u00e0 56,8 V).<\/li><li>\u00c9tape 2 (Absorption \/ Tension constante) : Le MPPT maintient la tension \u00e0 56,0 V\u00e0 56,8 V pendant 15 \u00e0 30 minutes, tandis que le courant de charge diminue jusqu\u2019\u00e0 une valeur inf\u00e9rieure \u00e0 $0,05\\text{C}$ (ou $0,01\\text{C}$ lors des tests \u00e0 pleine capacit\u00e9), ce qui laisse au BMS le temps d\u2019\u00e9quilibrer les 16 cellules.<\/li><li>\u00c9tape 3 (maintien, 53,6 V \u2013 54,0 V) : bien que les batteries LFP d\u00e9connect\u00e9es et stock\u00e9es n\u2019aient pas besoin d\u2019une charge de maintien, un syst\u00e8me d\u2019onduleur solaire actif n\u00e9cessite une \u00e9tape de maintien r\u00e9gl\u00e9e entre 53,6 V et 54,0 V, juste au-dessus du plateau de repos \u00e0 100 %. Le maintien de la charge d'entretien \u00e0 53,8 V permet au MPPT solaire d'alimenter les charges CA du foyer via le bus CC tout l'apr\u00e8s-midi, tout en conservant la batterie \u00e0 pleine charge pour le coucher du soleil, sans provoquer de microcycles au niveau des cellules ni les maintenir \u00e0 56,8 V pendant des heures.<\/li><\/ol><\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c1349127 auto-image elementor-widget elementor-widget-image\" data-id=\"c1349127\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"1536\" height=\"623\" src=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/10\/lifepo4-solar-cccv-3-stage-charging-1536x623.webp\" class=\"attachment-1536x1536 size-1536x1536 wp-image-7747\" alt=\"Profil de charge solaire corrig\u00e9 pour une batterie LiFePO4 de 16S \u00e0 51,2 V, avec une phase de charge rapide entre 56,0 et 56,8 V, une phase d&#039;absorption entre 56,0 et 56,8 V et une phase de maintien entre 53,6 et 54,0 V\" srcset=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/10\/lifepo4-solar-cccv-3-stage-charging-1536x623.webp 1536w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/10\/lifepo4-solar-cccv-3-stage-charging-300x122.webp 300w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/10\/lifepo4-solar-cccv-3-stage-charging-1024x415.webp 1024w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/10\/lifepo4-solar-cccv-3-stage-charging-768x311.webp 768w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/10\/lifepo4-solar-cccv-3-stage-charging-2048x830.webp 2048w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/10\/lifepo4-solar-cccv-3-stage-charging-18x7.webp 18w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/10\/lifepo4-solar-cccv-3-stage-charging-600x243.webp 600w\" sizes=\"(max-width: 1536px) 100vw, 1536px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b082edef auto-h3 elementor-widget elementor-widget-heading\" data-id=\"b082edef\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Trois r\u00e9glages qui endommagent les batteries solaires LiFePO4<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0167a7da auto-p elementor-widget elementor-widget-heading\" data-id=\"0167a7da\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\"><ol><li>Si l'\u00e9galisation des batteries au plomb-acide reste activ\u00e9e : les profils de charge des batteries au plomb-acide font monter la tension au-del\u00e0 de 60 V\u201362 V afin de d\u00e9sulfater les plaques de plomb. Sur une batterie LiFePO\u2084 de type 16S, une impulsion d\u2019\u00e9galisation de 60 V d\u00e9clenche le verrouillage de surtension du BMS et peut endommager les MOSFET si elle se r\u00e9p\u00e8te. R\u00e9glez l\u2019\u00e9galisation sur \u00ab D\u00e9sactiv\u00e9e \u00bb \/ 0 minute (ou r\u00e9glez la tension d\u2019\u00e9galisation \u00e0 une valeur \u00e9gale \u00e0 la tension de charge si le micrologiciel de l\u2019onduleur ne permet pas la valeur z\u00e9ro).<\/li><li>Activation de la compensation de temp\u00e9rature : les chargeurs pour batteries au plomb augmentent la tension de charge de $-3\\text{ \u00e0 }-5\\text{ mV}\/^\\circ\\text{C}\/\\text{cellule}$ par temps froid. Sur un banc de batteries au lithium de 48 V \u00e0 $5^\\circ\\text{C}$, une sonde de temp\u00e9rature pour batteries au plomb-acide fait grimper la tension de charge de pr\u00e8s de 2 V au-dessus de la valeur programm\u00e9e, ce qui provoque des d\u00e9clenchements COVP. R\u00e9glez la compensation de temp\u00e9rature sur $0\\text{ mV}\/^\\circ\\text{C}$ et d\u00e9branchez les sondes de temp\u00e9rature pour batteries au plomb lorsque vous utilisez le mode de tension manuel.<\/li><li>Charge en dessous de $0^\\circ\\text{C}$ ($32^\\circ\\text{F}$) sans protection thermique : alors que les batteries LFP semi-solides MegSolid 51,2 V se d\u00e9chargent jusqu'\u00e0 $-20^\\circ\\text{C}$ ($-4^\\circ\\text{F}$), la charge d\u2019une anode LFP en dessous de $0^\\circ\\text{C}$ provoque un d\u00e9p\u00f4t de lithium m\u00e9tallique \u00e0 la surface du graphite et une perte de capacit\u00e9 irr\u00e9versible. Le BMS de MegSolid impose une plage de charge comprise entre $0^\\circ\\text{C}$ et $45^\\circ\\text{C}$.<\/li><\/ol><\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-baff7cdf auto-h2 elementor-widget elementor-widget-heading\" data-id=\"baff7cdf\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Boucle ferm\u00e9e ou boucle ouverte : pourquoi les batteries intelligentes de 51,2 V permettent d'\u00e9viter les approximations de tension<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b9461b57 auto-p elementor-widget elementor-widget-heading\" data-id=\"b9461b57\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">La programmation manuelle des modes \" Bulk \", \u00ab Absorption \u00bb, \u00ab Float \u00bb et \u00ab Coupure en cas de basse tension \u00bb dans le \u00ab Mode en boucle ouverte d\u00e9fini par l'utilisateur (USE) en boucle ouverte \u00bb fonctionne avec les anciens onduleurs, mais pr\u00e9sente deux inconv\u00e9nients : l\u2019onduleur se base sur la tension aux bornes pour estimer le taux de charge (SoC), et il ne peut pas ajuster le courant de charge si une seule cellule s\u2019\u00e9chauffe ou pr\u00e9sente un d\u00e9s\u00e9quilibre.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-317692a9 auto-p elementor-widget elementor-widget-heading\" data-id=\"317692a9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">moderne <strong><a href=\"https:\/\/www.solidess.com\/fr\/piles\/stockage-denergie-residentiel\/\" target=\"_blank\" style=\"color:#61ce70\">Batteries domestiques intelligentes de 51,2 V avec configuration automatique via CANbus et RS485<\/a><\/strong> fonctionner en mode de communication en boucle ferm\u00e9e :<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-eaa01bfb elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"eaa01bfb\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Raccordez un c\u00e2ble de communication RJ45 standard entre le port CAN ou RS485 de la batterie et votre onduleur hybride (y compris celui de MegSolid) <strong><a href=\"https:\/\/www.solidess.com\/fr\/product\/onduleur-de-stockage-denergie-monophase-megsolid\/\" target=\"_blank\" style=\"color:#61ce70\">Onduleur hybride monophas\u00e9 de 3 \u00e0 6 kW<\/a><\/strong> et <strong><a href=\"https:\/\/www.solidess.com\/fr\/product\/onduleur-hybride-triphase-mgesolid\/\" target=\"_blank\" style=\"color:#61ce70\">Onduleur hybride triphas\u00e9 de 30 \u00e0 50 kW<\/a><\/strong>, ainsi que les protocoles courants utilis\u00e9s par Deye, Victron, Growatt, Sol-Ark, Luxpower et GoodWe).<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Le BMS de la batterie fait office de contr\u00f4leur principal : toutes les secondes, il transmet \u00e0 l'onduleur, en temps r\u00e9el, le niveau de charge (SoC) calcul\u00e9 en coulombs (0 % \u00e0 100 %), l'\u00e9tat de sant\u00e9 (SoH), les limites exactes de tension de charge ainsi que les limites de courant de charge et de d\u00e9charge.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-92bd9244 auto-h3 elementor-widget elementor-widget-heading\" data-id=\"92bd9244\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Gamme phare de batteries MegSolid 51,2 V (16S)<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-18f06b7c auto-table elementor-widget elementor-widget-text-editor\" data-id=\"18f06b7c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"cea-table-wrap\"><table><thead><tr><th>Mod\u00e8le<\/th><th>Chimie et format<\/th><th>Capacit\u00e9 nominale et \u00e9nergie<\/th><th>Tension et courant de fonctionnement<\/th><th>Dur\u00e9e de vie et \u00e9volutivit\u00e9 parall\u00e8le<\/th><\/tr><\/thead><tbody><tr><td><strong><a href=\"https:\/\/www.solidess.com\/fr\/product\/batterie-de-stockage-denergie-solide-megsold\/\" target=\"_blank\" style=\"color:#61ce70\">MEGA-512314FL1<\/a><\/strong><\/td><td>LiFePO4 semi-solide 51,2 V (bloc fixe en t\u00f4le, IP21\/IP65)<\/td><td>314 Ah \/ 16,07 kWh<\/td><td>43,2 V \u2013 57,6 V \u00b7 200 A en charge \/ 200 A en d\u00e9charge ($\\le 15\\text{ m}\\Omega$)<\/td><td>8 000 cycles (profondeur de d\u00e9charge de 80 %) \u00b7 RS485 \/ RS232 \/ CAN + Wi-Fi\/BT en option<\/td><\/tr><tr><td><strong><a href=\"https:\/\/www.solidess.com\/fr\/product\/bloc-batterie-au-lithium-amovible\/\" target=\"_blank\" style=\"color:#61ce70\">MEGA-512314 Mobile<\/a><\/strong><\/td><td>Batterie LFP monobloc de 51,2 V (bloc sur pied \u00e0 roulettes, IP21)<\/td><td>314 Ah \/ 16,076 kWh<\/td><td>40,0 V \u2013 58,4 V \u00b7 200 A en charge \/ 200 A en d\u00e9charge<\/td><td>$\\ge 6 000$ cycles \u00b7 Mise en parall\u00e8le jusqu'\u00e0 6 unit\u00e9s (96,4 kWh) \u00b7 RS485 \/ CAN \/ RS232<\/td><\/tr><\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-55343375 auto-image elementor-widget elementor-widget-image\" data-id=\"55343375\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"1536\" height=\"864\" src=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/10\/lifepo4-48v-voltage-key-points-overview-1536x864.webp\" class=\"attachment-1536x1536 size-1536x1536 wp-image-7745\" alt=\"Guide de tension LiFePO4 de 48 V (51,2 V) distinguant la plage de r\u00e9f\u00e9rence g\u00e9n\u00e9rique 16S (40,0\u201358,4 V) de la plage de fonctionnement du MEG-Solid-512314FL1 (43,2\u201357,6 V), avec plateau de niveau de charge (SoC) et param\u00e8tres de charge\" srcset=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/10\/lifepo4-48v-voltage-key-points-overview-1536x864.webp 1536w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/10\/lifepo4-48v-voltage-key-points-overview-300x169.webp 300w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/10\/lifepo4-48v-voltage-key-points-overview-1024x576.webp 1024w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/10\/lifepo4-48v-voltage-key-points-overview-768x432.webp 768w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/10\/lifepo4-48v-voltage-key-points-overview-18x10.webp 18w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/10\/lifepo4-48v-voltage-key-points-overview-600x338.webp 600w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/10\/lifepo4-48v-voltage-key-points-overview.webp 2048w\" sizes=\"(max-width: 1536px) 100vw, 1536px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8b2a9583 auto-p elementor-widget elementor-widget-heading\" data-id=\"8b2a9583\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\"><strong><a href=\"https:\/\/www.solidess.com\/fr\/piles\/stockage-denergie-residentiel\/\" target=\"_blank\" style=\"color:#61ce70\">D\u00e9couvrir toutes les batteries solaires semi-solides et LiFePO4 de 48 V (51,2 V) \u2192<\/a><\/strong><\/p>\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-f66700c3 auto-faq e-flex e-con-boxed e-con e-child\" data-id=\"f66700c3\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-55c74e81 elementor-widget elementor-widget-heading\" data-id=\"55c74e81\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">FAQ<\/h2>\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-acb4c798 e-con-full e-flex e-con e-child\" data-id=\"acb4c798\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-84d1fef7 elementor-widget elementor-widget-n-accordion\" data-id=\"84d1fef7\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;default_state&quot;:&quot;all_collapsed&quot;,&quot;max_items_expended&quot;:&quot;one&quot;,&quot;n_accordion_animation_duration&quot;:{&quot;unit&quot;:&quot;ms&quot;,&quot;size&quot;:400,&quot;sizes&quot;:[]}}\" data-widget_type=\"nested-accordion.default\">\n\t\t\t\t\t\t\t<div class=\"e-n-accordion\" aria-label=\"Accord\u00e9on. Ouvrez les liens \u00e0 l&#039;aide de la touche Entr\u00e9e ou de la barre d&#039;espace, fermez-les avec la touche \u00c9chap et naviguez \u00e0 l&#039;aide des touches fl\u00e9ch\u00e9es.\">\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2220\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"1\" tabindex=\"0\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2220\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Les batteries semi-solides de 48 V utilisent-elles les m\u00eames tensions de charge que les batteries LiFePO4 standard ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2220\" class=\"elementor-element elementor-element-de416a86 e-con-full e-flex e-con e-child\" data-id=\"de416a86\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2220\" class=\"elementor-element elementor-element-5b9176ca e-con-full e-flex e-con e-child\" data-id=\"5b9176ca\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a68ef2fb elementor-widget elementor-widget-heading\" data-id=\"a68ef2fb\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Elles partagent la tension nominale de cellule LFP, mais la tension de charge maximale et la plage de fonctionnement exactes varient selon le mod\u00e8le. Le mod\u00e8le MEG-Solid-512314FL1 est sp\u00e9cifi\u00e9 avec une tension de charge de 57,6 V et une plage de fonctionnement comprise entre 43,2 V et 57,6 V. Ne partez pas du principe que tous les packs 16S acceptent une tension de 58,4 V.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2221\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"2\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2221\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Comment puis-je savoir si ma batterie de 48 V est de type 15S ou 16S ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2221\" class=\"elementor-element elementor-element-b4041ffa e-con-full e-flex e-con e-child\" data-id=\"b4041ffa\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2221\" class=\"elementor-element elementor-element-6e159213 e-con-full e-flex e-con e-child\" data-id=\"6e159213\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-96e87f1c elementor-widget elementor-widget-heading\" data-id=\"96e87f1c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">V\u00e9rifiez la plaque signal\u00e9tique de la batterie et la fiche technique correspondante pour conna\u00eetre le nombre de cellules en s\u00e9rie et la tension nominale. Un pack LFP 15S a une tension nominale de 48,0 V ; un pack 16S a une tension nominale de 51,2 V. Ne choisissez jamais les r\u00e9glages MPPT en vous basant uniquement sur la mention informelle \u201c 48 V \u201d.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2222\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"3\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2222\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Pourquoi la tension est-elle un indicateur peu fiable de l'\u00e9tat de charge (SoC) entre 30 % et 80 % ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2222\" class=\"elementor-element elementor-element-6359a8fa e-con-full e-flex e-con e-child\" data-id=\"6359a8fa\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2222\" class=\"elementor-element elementor-element-df680b48 e-con-full e-flex e-con e-child\" data-id=\"df680b48\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-7b152ff8 elementor-widget elementor-widget-heading\" data-id=\"7b152ff8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">La tension de d\u00e9charge des batteries LFP pr\u00e9sente un plateau relativement stable sur une grande partie de la plage interm\u00e9diaire de l'\u00e9tat de charge (SoC). Le courant de charge et la temp\u00e9rature influencent \u00e9galement la tension aux bornes. Un syst\u00e8me de gestion de batterie (BMS) utilisant l'int\u00e9gration du courant et la surveillance des cellules fournit une estimation de l'\u00e9tat de charge (SoC) plus fiable qu'un simple tableau de tensions d'onduleur.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2223\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"4\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2223\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Quelle tension de charge ou d'absorption dois-je utiliser pour une batterie 16S de 51,2 V ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2223\" class=\"elementor-element elementor-element-cc24c600 e-con-full e-flex e-con e-child\" data-id=\"cc24c600\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2223\" class=\"elementor-element elementor-element-e1d2f8fd e-con-full e-flex e-con e-child\" data-id=\"e1d2f8fd\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-3757f2e1 elementor-widget elementor-widget-heading\" data-id=\"3757f2e1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Le guide indique une plage de 56,0 V \u00e0 56,8 V comme objectif quotidien type pour une configuration g\u00e9n\u00e9rique 16S LFP. La fiche technique du produit MEG-Solid-512314FL1 indique une tension de charge de 57,6 V. V\u00e9rifiez la valeur de consigne approuv\u00e9e et la dur\u00e9e d'absorption en vous r\u00e9f\u00e9rant aux manuels sp\u00e9cifiques de la batterie et de l'onduleur avant la mise en service.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2224\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"5\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2224\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Quelle tension de maintien dois-je utiliser pour une batterie solaire LiFePO4 de 48 V ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2224\" class=\"elementor-element elementor-element-a753324a e-con-full e-flex e-con e-child\" data-id=\"a753324a\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2224\" class=\"elementor-element elementor-element-39159b7d e-con-full e-flex e-con e-child\" data-id=\"39159b7d\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-32173381 elementor-widget elementor-widget-heading\" data-id=\"32173381\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Le guide indique que la plage de tension de maintien typique d'un syst\u00e8me 16S se situe entre 53,6 V et 54,0 V. Certaines combinaisons de batteries et d'onduleurs utilisent une logique de maintien diff\u00e9rente ou permettent de d\u00e9sactiver le mode de maintien. Respectez le profil recommand\u00e9 par le fabricant de la batterie et \u00e9vitez de maintenir le bloc de batteries \u00e0 une tension d'absorption \u00e9lev\u00e9e sans raison valable.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2225\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"6\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2225\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Quelles fonctions d'un chargeur pour batteries au plomb doivent \u00eatre d\u00e9sactiv\u00e9es pour les batteries LiFePO4 ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2225\" class=\"elementor-element elementor-element-3e64a122 e-con-full e-flex e-con e-child\" data-id=\"3e64a122\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2225\" class=\"elementor-element elementor-element-d1b3b434 e-con-full e-flex e-con e-child\" data-id=\"d1b3b434\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-d940df64 elementor-widget elementor-widget-heading\" data-id=\"d940df64\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">D\u00e9sactivez l'\u00e9galisation des batteries au plomb et n'appliquez pas de courbe de compensation de temp\u00e9rature pour les batteries au plomb, sauf si le fabricant de la batterie l'exige express\u00e9ment. En mode manuel, v\u00e9rifiez que la compensation de temp\u00e9rature est d\u00e9sactiv\u00e9e et assurez-vous que le r\u00e9gulateur ne peut pas \u00e9mettre d'impulsion d'\u00e9galisation \u00e0 haute tension.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2226\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"7\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2226\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Puis-je recharger une batterie semi-solide MegSolid de 51,2 V \u00e0 une temp\u00e9rature inf\u00e9rieure \u00e0 0 \u00b0C ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2226\" class=\"elementor-element elementor-element-31dd9595 e-con-full e-flex e-con e-child\" data-id=\"31dd9595\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2226\" class=\"elementor-element elementor-element-36c41658 e-con-full e-flex e-con e-child\" data-id=\"36c41658\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-b12951eb elementor-widget elementor-widget-heading\" data-id=\"b12951eb\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Non. La fiche technique du MEG-Solid-512314FL1 indique une plage de temp\u00e9rature de charge comprise entre 0 \u00b0C et 45 \u00b0C. Sa plage de d\u00e9charge indiqu\u00e9e s'\u00e9tend de \u221220 \u00b0C \u00e0 60 \u00b0C. Les limites de charge et de d\u00e9charge sont diff\u00e9rentes et ne doivent pas \u00eatre confondues.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2227\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"8\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2227\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Que doit v\u00e9rifier un installateur sud-africain avant de mettre en service un onduleur LiFePO4 de 48 V ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2227\" class=\"elementor-element elementor-element-90ef55d9 e-con-full e-flex e-con e-child\" data-id=\"90ef55d9\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2227\" class=\"elementor-element elementor-element-c1d46f55 e-con-full e-flex e-con e-child\" data-id=\"c1d46f55\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-eb202b02 elementor-widget elementor-widget-heading\" data-id=\"eb202b02\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">V\u00e9rifiez si la batterie est de type 15S ou 16S, respectez les limites de tension sp\u00e9cifiques au mod\u00e8le, v\u00e9rifiez la compatibilit\u00e9 CAN ou RS485 lorsqu'un contr\u00f4le en boucle ferm\u00e9e est requis, et v\u00e9rifiez les exigences locales applicables en mati\u00e8re d'installation et de services publics. Ce guide ne d\u00e9finit pas de profil de tension sp\u00e9cifique \u00e0 l'Afrique du Sud.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2228\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"9\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2228\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Que doit v\u00e9rifier un acheteur australien lorsqu'il choisit une batterie de 51,2 V adapt\u00e9e \u00e0 un onduleur solaire ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2228\" class=\"elementor-element elementor-element-812a0f57 e-con-full e-flex e-con e-child\" data-id=\"812a0f57\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2228\" class=\"elementor-element elementor-element-03eee3a6 e-con-full e-flex e-con e-child\" data-id=\"03eee3a6\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-69cf3db0 elementor-widget elementor-widget-heading\" data-id=\"69cf3db0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">V\u00e9rifiez la tension de charge homologu\u00e9e de la batterie, la plage de tension de la batterie de l'onduleur, le courant de charge maximal, le protocole de communication du BMS ainsi que toutes les homologations \u00e9lectriques locales requises. Le pays n'influe pas sur le nombre de cellules du pack ni sur les limites de tension fix\u00e9es par le fabricant.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2229\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"10\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2229\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Les temp\u00e9ratures \u00e9lev\u00e9es en Arabie saoudite ont-elles une incidence sur le tableau des tensions du LiFePO4 48 V ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2229\" class=\"elementor-element elementor-element-ef53e453 e-con-full e-flex e-con e-child\" data-id=\"ef53e453\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2229\" class=\"elementor-element elementor-element-0d4f0ffb e-con-full e-flex e-con e-child\" data-id=\"0d4f0ffb\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-553ae32f elementor-widget elementor-widget-heading\" data-id=\"553ae32f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">La tension nominale des cellules reste inchang\u00e9e, mais la temp\u00e9rature de fonctionnement peut avoir une incidence sur la puissance disponible, l'autorisation de charge et la dur\u00e9e de vie de la batterie. V\u00e9rifiez les limites de temp\u00e9rature pr\u00e9cises du produit, les conditions d'installation et les exigences de d\u00e9classement de l'onduleur. Ce guide ne fournit pas de r\u00e9glage de tension sp\u00e9cifique \u00e0 l'Arabie saoudite.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e47a5eef auto-h2 elementor-widget elementor-widget-heading\" data-id=\"e47a5eef\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">T\u00e9l\u00e9chargez la fiche technique de votre batterie solaire 48 V et le guide d'installation de l'onduleur<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-04265637 auto-p elementor-widget elementor-widget-heading\" data-id=\"04265637\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Vous avez besoin d'aide pour adapter un parc de batteries semi-solides de 51,2 V \u00e0 votre onduleur solaire ou pour dimensionner un projet r\u00e9sidentiel ou de petite envergure dans le secteur commercial ? <strong><a href=\"https:\/\/www.solidess.com\/fr\/contacter-megsolid\/\" target=\"_blank\" style=\"color:#61ce70\">Contacter l'\u00e9quipe technique de MegSolid<\/a><\/strong> pour demander nos fiches techniques sur la batterie hybride \u00e0 semi-conducteurs de 51,2 V et 314 Ah, le guide de brochage CAN\/RS485 de l'onduleur et nos tarifs de gros, ou pour d\u00e9couvrir notre gamme compl\u00e8te de <strong><a href=\"https:\/\/www.solidess.com\/fr\/systemes-de-stockage-denergie-a-letat-solide\/\" target=\"_blank\" style=\"color:#61ce70\">syst\u00e8mes de stockage d'\u00e9nergie \u00e0 l'\u00e9tat solide<\/a><\/strong>.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9cb0e7b5 elementor-tablet-align-center elementor-align-center auto-cta elementor-widget elementor-widget-button\" data-id=\"9cb0e7b5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"#elementor-action%3Aaction%3Dpopup%3Aopen%26settings%3DeyJpZCI6Ijk0OCIsInRvZ2dsZSI6ZmFsc2V9\" target=\"_blank\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Contacter MegSolid | Demander la fiche technique du mod\u00e8le 314Ah et le guide CAN\/RS485<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Utilisez un tableau des tensions LiFePO4 \u00e0 48 V (51,2 V) pour comprendre le niveau de charge (SoC) au repos, les diff\u00e9rences entre les packs 15S et 16S, les r\u00e9glages de charge en masse et de maintien pour l'\u00e9nergie solaire, ainsi que la communication avec le BMS pour les batteries r\u00e9sidentielles MegSolid.<\/p>","protected":false},"author":4,"featured_media":7744,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"_joinchat":[],"footnotes":""},"categories":[1,711],"tags":[848,849,850,847,854,852,853,851],"class_list":["post-7748","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-bess","category-solid-state-battery-technology","tag-48v-battery","tag-51-2v-battery","tag-battery-state-of-charge","tag-lifepo4-voltage-range","tag-megsolid-residential-energy-storage","tag-mppt-charging","tag-semi-solid-lifepo4","tag-solar-battery-charging"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/posts\/7748","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/comments?post=7748"}],"version-history":[{"count":4,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/posts\/7748\/revisions"}],"predecessor-version":[{"id":7752,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/posts\/7748\/revisions\/7752"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/media\/7744"}],"wp:attachment":[{"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/media?parent=7748"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/categories?post=7748"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/tags?post=7748"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}