{"id":7931,"date":"2026-11-03T18:18:46","date_gmt":"2026-11-03T10:18:46","guid":{"rendered":"https:\/\/www.solidess.com\/?p=7931"},"modified":"2026-11-03T18:18:49","modified_gmt":"2026-11-03T10:18:49","slug":"guide-sur-les-batteries-au-lithium-certifiees-ul","status":"publish","type":"post","link":"https:\/\/www.solidess.com\/fr\/ul-certified-lithium-batteries-guide\/","title":{"rendered":"Batteries au lithium certifi\u00e9es UL : le guide B2B des normes UL 1642, UL 2054, UL 1973, UL 991 et UL 9540"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"7931\" class=\"elementor elementor-7931\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-bf4793c e-con-full auto-article-root e-flex e-con e-parent\" data-id=\"bf4793c\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-b4116df0 auto-p elementor-widget elementor-widget-heading\" data-id=\"b4116df0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">L'approvisionnement en batteries au lithium certifi\u00e9es UL destin\u00e9es aux micro-r\u00e9seaux nord-am\u00e9ricains, aux syst\u00e8mes de secours pour les t\u00e9l\u00e9communications ou aux b\u00e2timents commerciaux comporte souvent un pi\u00e8ge co\u00fbteux. De nombreux fournisseurs de batteries affirment en effet que leurs produits sont enti\u00e8rement conformes au simple fait que leurs cellules brutes internes b\u00e9n\u00e9ficient d'une homologation au titre de la norme UL 1642.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b5752a11 auto-p elementor-widget elementor-widget-heading\" data-id=\"b5752a11\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Les inspecteurs du b\u00e2timent, les responsables de la s\u00e9curit\u00e9 incendie et les autorit\u00e9s comp\u00e9tentes (AHJ) charg\u00e9es de faire respecter la norme NFPA 855 et l'article 706 du Code national de l'\u00e9lectricit\u00e9 (NEC) \u00e9valuent l'installation dans son ensemble plut\u00f4t que des cellules prises isol\u00e9ment. Plut\u00f4t que d'exiger que chaque projet obtienne une s\u00e9rie fixe de certificats distincts, les normes nord-am\u00e9ricaines de s\u00e9curit\u00e9 relatives aux batteries s'articulent autour de quatre niveaux d'\u00e9valuation distincts, en fonction de l'\u00e9tendue de l'\u00e9quipement et de l'architecture du syst\u00e8me :<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3289d5cf elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"3289d5cf\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Niveau 1 (\u00e9valuation des cellules) : la norme UL 1642 \u00e9value des cellules \u00e9lectrochimiques nues soumises \u00e0 des contraintes \u00e9lectriques, m\u00e9caniques et thermiques extr\u00eames.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Niveau 2 (\u00c9valuation des blocs-batteries et des modules) : la norme UL 2054 s'applique aux blocs-batteries portables \u00e0 usage domestique et professionnel, tandis que la norme UL 1973 concerne les blocs-batteries et les modules destin\u00e9s au stockage d'\u00e9nergie stationnaire, \u00e0 l'alimentation auxiliaire des v\u00e9hicules et aux applications de transport ferroviaire l\u00e9ger (LER).<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Niveau 3 (\u00c9valuation de la s\u00e9curit\u00e9 fonctionnelle et des commandes) : les normes UL 991 et UL 1998 \u00e9valuent le mat\u00e9riel de commande \u00e0 semi-conducteurs et les logiciels programmables lorsque les fonctions de s\u00e9curit\u00e9 d\u00e9pendent de la logique \u00e9lectronique du BMS (cette \u00e9valuation est g\u00e9n\u00e9ralement r\u00e9alis\u00e9e dans le cadre d'une analyse du pack ou du syst\u00e8me global, plut\u00f4t que sous la forme de certificats universels autonomes pour chaque BMS).<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Niveau 4 (\u00c9valuation au niveau du syst\u00e8me) : La norme UL 9540 pr\u00e9voit une \u00e9valuation de la s\u00e9curit\u00e9 au niveau du syst\u00e8me portant sur les fonctions de charge et de d\u00e9charge, de protection, de commande, de communication et de bo\u00eetier, en se r\u00e9f\u00e9rant \u00e0 des normes telles que les normes UL 1973 et UL 1741, en fonction de l'architecture et des composants sp\u00e9cifiques du syst\u00e8me.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d88ceb23 auto-p elementor-widget elementor-widget-heading\" data-id=\"d88ceb23\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">MegSolid con\u00e7oit ses plateformes de cellules, de modules et d'armoires en s'appuyant sur cette architecture r\u00e9glementaire gr\u00e2ce \u00e0 notre <strong><a href=\"https:\/\/www.solidess.com\/fr\/systemes-de-stockage-denergie-a-letat-solide\/\" target=\"_blank\" style=\"color:#61ce70\">Syst\u00e8mes de stockage d'\u00e9nergie \u00e0 l'\u00e9tat solide<\/a><\/strong> et modulaire <strong><a href=\"https:\/\/www.solidess.com\/fr\/piles\/stockage-denergie-ci\/\" target=\"_blank\" style=\"color:#61ce70\">Stockage d'\u00e9nergie \u00e0 usage commercial et industriel (C&amp;I)<\/a><\/strong> des solutions, accompagn\u00e9es de fichiers de certification sp\u00e9cifiques \u00e0 chaque mod\u00e8le et dont le champ d'application a \u00e9t\u00e9 v\u00e9rifi\u00e9 lors de la revue technique.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a197d3fb auto-image elementor-widget elementor-widget-image\" data-id=\"a197d3fb\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"1536\" height=\"1024\" src=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/ul-certification-lithium-batteries-key-points-overview-v2-1536x1024.webp\" class=\"attachment-1536x1536 size-1536x1536 wp-image-7928\" alt=\"Pr\u00e9sentation g\u00e9n\u00e9rale de la certification UL des batteries, couvrant la s\u00e9curit\u00e9 des cellules selon la norme UL 1642, les modules de batteries stationnaires selon la norme UL 1973, la s\u00e9curit\u00e9 des syst\u00e8mes de gestion de batterie (BMS) selon les normes UL 991 et UL 1998, ainsi que l&#039;\u00e9valuation compl\u00e8te des syst\u00e8mes de stockage d&#039;\u00e9nergie (ESS) selon la norme UL 9540\" srcset=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/ul-certification-lithium-batteries-key-points-overview-v2-1536x1024.webp 1536w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/ul-certification-lithium-batteries-key-points-overview-v2-300x200.webp 300w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/ul-certification-lithium-batteries-key-points-overview-v2-1024x683.webp 1024w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/ul-certification-lithium-batteries-key-points-overview-v2-768x512.webp 768w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/ul-certification-lithium-batteries-key-points-overview-v2-18x12.webp 18w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/ul-certification-lithium-batteries-key-points-overview-v2-600x400.webp 600w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/ul-certification-lithium-batteries-key-points-overview-v2.webp 1920w\" sizes=\"(max-width: 1536px) 100vw, 1536px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3d6f3998 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"3d6f3998\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Tableau comparatif complet : d\u00e9cryptage des normes UL relatives aux batteries selon quatre niveaux d'\u00e9valuation<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0cb7edd6 auto-p elementor-widget elementor-widget-heading\" data-id=\"0cb7edd6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Les \u00e9quipes charg\u00e9es de l'ing\u00e9nierie, de l'approvisionnement et de la construction (EPC) qui examinent les dossiers soumis par les fournisseurs doivent v\u00e9rifier que chaque norme UL correspond bien \u00e0 son champ d'application l\u00e9gal et \u00e0 ses limites physiques d'essai. La pr\u00e9sentation d'un rapport au niveau de la cellule ou d'un certificat de batterie portable pour une installation commerciale fixe entra\u00eene le rejet du permis lors de l'examen des plans.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e9a14808 auto-p elementor-widget elementor-widget-heading\" data-id=\"e9a14808\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Le tableau 1 pr\u00e9sente les quatre niveaux d'\u00e9valuation des batteries au lithium certifi\u00e9es UL selon les normes nord-am\u00e9ricaines, ainsi que la m\u00e9thode d'essai au feu UL 9540A correspondante.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-99f771c3 auto-h3 elementor-widget elementor-widget-heading\" data-id=\"99f771c3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Tableau 1 : Matrice hi\u00e9rarchique d'\u00e9valuation de la s\u00e9curit\u00e9 des batteries d'UL<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b3f6ed8a auto-table elementor-widget elementor-widget-text-editor\" data-id=\"b3f6ed8a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"cea-table-wrap\"><table><thead><tr><th>Standard<\/th><th>Niveau d'\u00e9valuation<\/th><th>P\u00e9rim\u00e8tre des \u00e9quipements concern\u00e9s<\/th><th>Certification \/ R\u00e9sultats<\/th><\/tr><\/thead><tbody><tr><td>UL 1642<\/td><td>Niveau 1 : Composant de base (cellule)<\/td><td>Piles au lithium primaires et secondaires<\/td><td>Composant reconnu par l'UR (R invers\u00e9)<\/td><\/tr><tr><td>UL 2054<\/td><td>Niveau 2A : Kit portable<\/td><td>Outils \u00e9lectriques, robotique mobile, dispositifs m\u00e9dicaux<\/td><td>Kit homologu\u00e9 ou reconnu par UL<\/td><\/tr><tr><td>UL 1973<\/td><td>Niveau 2B : \u00c9quipements fixes, auxiliaires et pack LER<\/td><td>Racks fixes pour syst\u00e8mes de stockage d'\u00e9nergie par batterie (BESS), alimentation auxiliaire des v\u00e9hicules, tramway \u00e9lectrique l\u00e9ger<\/td><td>Module homologu\u00e9 ou reconnu par UL<\/td><\/tr><tr><td>UL 991 \/ 1998<\/td><td>Niveau 3 : Contr\u00f4le et s\u00e9curit\u00e9 fonctionnelle<\/td><td>Mat\u00e9riel \u00e0 semi-conducteurs BMS (991) et logiciels BMS (1998), le cas \u00e9ch\u00e9ant<\/td><td>\u00c9valu\u00e9 au regard de la norme de r\u00e9f\u00e9rence<\/td><\/tr><tr><td>UL 9540<\/td><td>Niveau 4 : ESS au niveau du syst\u00e8me<\/td><td>Syst\u00e8me ESS complet (charge\/d\u00e9charge, protection, contr\u00f4le, communications)<\/td><td>Syst\u00e8me homologu\u00e9 UL (ou \u00e9quivalent NRTL)<\/td><\/tr><tr><td>UL 9540A<\/td><td>M\u00e9thode d'essai au feu (sans \u00e9valuation \u00ab r\u00e9ussi\/\u00e9chou\u00e9 \u00bb)<\/td><td>Propagation d'un incendie d\u00fb \u00e0 un emballement thermique au niveau d'une cellule, d'un module, d'une unit\u00e9 et d'une installation<\/td><td>Rapport sur les donn\u00e9es d'essai (examen NFPA 855)<\/td><\/tr><\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d2cf15ec auto-p elementor-widget elementor-widget-heading\" data-id=\"d2cf15ec\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Principaux domaines et limites des tests :<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5f745cb9 elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"5f745cb9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">UL 1642 : \u00c9value le bo\u00eetier nu de la cellule, l'int\u00e9grit\u00e9 du s\u00e9parateur et le syst\u00e8me de d\u00e9compression de s\u00e9curit\u00e9 dans le cadre de protocoles de mise \u00e0 l'\u00e9preuve \u00e9lectrique, m\u00e9canique et thermique d\u00e9finis en fonction du type de cellule, de la composition chimique (primaire ou secondaire) et de la g\u00e9om\u00e9trie de l'\u00e9chantillon.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Norme UL 2054 : \u00c9value la durabilit\u00e9 des petits bo\u00eetiers portables \u00e0 usage domestique et commercial, ainsi que la protection des cartes contre les pannes isol\u00e9es ; ne s'applique pas aux installations fixes et permanentes de syst\u00e8mes de stockage d'\u00e9nergie par batterie (BESS) dans les b\u00e2timents.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">UL 1973 : \u00c9value les modules et les packs de batteries destin\u00e9s au stockage d'\u00e9nergie stationnaire, \u00e0 l'alimentation auxiliaire des v\u00e9hicules et aux trains l\u00e9gers sur rail (LER), en portant notamment sur la r\u00e9sistance di\u00e9lectrique, les dispositifs de protection et le confinement des d\u00e9faillances internes des cellules.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">UL 991 et UL 1998 : applicables lorsque des fonctions de protection essentielles \u00e0 la s\u00e9curit\u00e9 d\u00e9pendent d'une \u00e9lectronique \u00e0 semi-conducteurs ou d'un micrologiciel programmable ; \u00e9valu\u00e9es en fonction de l'architecture de protection du BMS plut\u00f4t que d'\u00eatre exig\u00e9es sous forme de certificats autonomes pour chaque BMS.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">UL 9540 : Fournit une \u00e9valuation compl\u00e8te de la s\u00e9curit\u00e9 au niveau du syst\u00e8me, couvrant les fonctions de charge et de d\u00e9charge, de protection, de contr\u00f4le, de communication et de bo\u00eetier, en se r\u00e9f\u00e9rant aux normes applicables telles que les normes UL 1973 et UL 1741, en fonction de l'architecture du syst\u00e8me.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-13c25b89 auto-p elementor-widget elementor-widget-heading\" data-id=\"13c25b89\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\"><strong>Note relative \u00e0 la v\u00e9rification des achats :<\/strong> Lorsque vous examinez les fiches techniques des fournisseurs, demandez toujours le certificat de conformit\u00e9 (CoC) original et v\u00e9rifiez bien la version exacte de la norme, le num\u00e9ro de mod\u00e8le et le nom du demandeur dans le r\u00e9pertoire du laboratoire \u00e9metteur avant de signer un contrat de fourniture d'\u00e9quipements.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3b3ec0a8 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"3b3ec0a8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Niveau d'\u00e9valuation 1 : Explications sur la s\u00e9curit\u00e9 au niveau des cellules et la norme UL 1642<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-54119377 auto-p elementor-widget elementor-widget-heading\" data-id=\"54119377\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">La qualification des composants destin\u00e9s aux batteries au lithium industrielles commence au niveau des cellules nues. Avant qu'un ing\u00e9nieur n'int\u00e8gre les cellules dans un module, le mod\u00e8le de cellule est \u00e9valu\u00e9 afin de d\u00e9terminer son comportement en cas d'utilisation abusive, conform\u00e9ment \u00e0 la norme UL 1642.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1a2b09f9 auto-h3 elementor-widget elementor-widget-heading\" data-id=\"1a2b09f9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Que v\u00e9rifie la norme UL 1642 ?<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-404e9fd9 auto-p elementor-widget elementor-widget-heading\" data-id=\"404e9fd9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">La norme UL 1642 (norme relative aux batteries au lithium) \u00e9value le risque d'incendie ou d'explosion lorsque des cellules au lithium primaires (non rechargeables) ou secondaires (rechargeables) non prot\u00e9g\u00e9es sont soumises \u00e0 des contraintes \u00e9lectriques, m\u00e9caniques et thermiques excessives. L'applicabilit\u00e9 des essais, le conditionnement des \u00e9chantillons (par exemple, \u00e0 l'\u00e9tat neuf ou apr\u00e8s cycles de charge\/d\u00e9charge) et les param\u00e8tres d'essai sp\u00e9cifiques d\u00e9pendent de la classification des cellules (primaires ou secondaires, rempla\u00e7ables par un technicien ou par l'utilisateur), de la masse des \u00e9chantillons et de la g\u00e9om\u00e9trie du bo\u00eetier :<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-469d3ba8 elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"469d3ba8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Protocoles en cas de maltraitance li\u00e9e \u00e0 l'\u00e9lectricit\u00e9 :<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">\u2014 Court-circuit externe : les bornes des cellules sont court-circuit\u00e9es sur une charge \u00e0 faible r\u00e9sistance d\u00e9finie par la norme, dans des conditions de temp\u00e9rature ambiante et de temp\u00e9rature \u00e9lev\u00e9e sp\u00e9cifi\u00e9es, afin d'\u00e9valuer l'int\u00e9grit\u00e9 du bo\u00eetier et le comportement de la ventilation.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">\u2014 Chargement anormal : conform\u00e9ment \u00e0 la norme UL 1642, les proc\u00e9dures de charge anormale s'appliquent aux piles primaires (non rechargeables) soumises \u00e0 des courants de charge non pr\u00e9vus, tandis que la protection contre la surcharge et les comportements abusifs des piles rechargeables (secondaires) sont \u00e9valu\u00e9es conform\u00e9ment aux normes applicables aux piles secondaires et aux blocs-batteries (telles que les normes UL 1973 ou UL 2054), selon le profil de charge sp\u00e9cifi\u00e9.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">\u2014 D\u00e9charge forc\u00e9e : s'applique aux cellules destin\u00e9es \u00e0 \u00eatre utilis\u00e9es dans des configurations en s\u00e9rie \u00e0 plusieurs cellules, dans lesquelles une cellule d\u00e9charg\u00e9e pourrait subir une inversion de polarit\u00e9 sous l'effet des autres cellules en s\u00e9rie, et non pas dans le cadre d'un test uniforme sur toutes les applications \u00e0 cellule unique.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Protocoles en cas de maltraitance physique :<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">\u2014 Essai de compression : soumet des \u00e9chantillons de cellules \u00e0 une compression m\u00e9canique entre des surfaces planes ou sp\u00e9cifi\u00e9es, conform\u00e9ment \u00e0 la g\u00e9om\u00e9trie du dispositif d'essai et aux param\u00e8tres de force d\u00e9finis pour le format et la taille des cellules dans la norme UL 1642.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">\u2014 Essai de choc : \u00e9value la r\u00e9sistance m\u00e9canique \u00e0 l'intrusion en laissant tomber un poids sp\u00e9cifi\u00e9 sur une tige en acier plac\u00e9e en travers d'\u00e9chantillons de cellules cylindriques ou prismatiques, conform\u00e9ment \u00e0 la proc\u00e9dure d'essai de choc pr\u00e9vue par la norme.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">\u2014 \u00c9valuations des chocs et des vibrations : les \u00e9chantillons de cellules concern\u00e9s sont soumis \u00e0 des impulsions de choc d\u2019acc\u00e9l\u00e9ration et \u00e0 des profils de vibration d\u00e9finis par la norme afin de v\u00e9rifier que les soudures internes des languettes, les raccords structurels et les joints d\u2019\u00e9tanch\u00e9it\u00e9 des bornes r\u00e9sistent au desserrage m\u00e9canique et aux fuites.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Protocoles en cas de surchauffe :<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">\u2014 Essai de chauffage : les \u00e9chantillons de cellules sont plac\u00e9s dans un four \u00e0 temp\u00e9rature contr\u00f4l\u00e9e, conform\u00e9ment \u00e0 la vitesse de mont\u00e9e en temp\u00e9rature, \u00e0 la temp\u00e9rature de maintien cible et \u00e0 la dur\u00e9e sp\u00e9cifi\u00e9es par la norme UL 1642 pour la classification et la composition chimique de l'\u00e9chantillon concern\u00e9.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">\u2014 Cycles thermiques : soumet les \u00e9chantillons de cellules \u00e0 des cycles alternant des temp\u00e9ratures extr\u00eames (hautes et basses) d\u00e9finies par la norme, pendant les dur\u00e9es de maintien et le nombre de cycles sp\u00e9cifi\u00e9s, afin de v\u00e9rifier l'int\u00e9grit\u00e9 du bo\u00eetier et des joints et de s'assurer qu'il n'y a pas de fuite d'\u00e9lectrolyte.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-16b73c2f auto-p elementor-widget elementor-widget-heading\" data-id=\"16b73c2f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Dans la norme UL 1642, l\u2019\u00e9valuation \u00ab r\u00e9ussi\/\u00e9chou\u00e9 \u00bb s\u2019applique \u00e0 chaque clause d\u2019essai sp\u00e9cifique plut\u00f4t qu\u2019\u00e0 un crit\u00e8re universel unique : en fonction de la proc\u00e9dure d\u2019essai et de la cat\u00e9gorie d\u2019\u00e9chantillon, les crit\u00e8res d\u2019acceptation permettent de d\u00e9terminer si l\u2019\u00e9chantillon pr\u00e9sente un risque d\u2019incendie, d\u2019explosion, de p\u00e9n\u00e9tration par des projectiles \u00e0 travers un \u00e9cran m\u00e9tallique d\u2019essai environnant (comme lors des essais de chauffage), une rupture du bo\u00eetier, ou une perte de masse excessive et un \u00e9coulement d\u2019\u00e9lectrolyte.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7ae7130e auto-h3 elementor-widget elementor-widget-heading\" data-id=\"7ae7130e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Distinction entre la norme UL 1642 (au niveau de la cellule) et la norme UL 1973 (au niveau du pack)<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c54b830e auto-p elementor-widget elementor-widget-heading\" data-id=\"c54b830e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">La norme UL 1642 \u00e9value la cellule \u00e9lectrochimique nue en tant que telle. Les fusibles, les contacteurs, les circuits d\u2019\u00e9quilibrage des cellules et les barri\u00e8res anti-arc du bo\u00eetier \u00e9tant des composants au niveau du pack plut\u00f4t que des \u00e9l\u00e9ments d\u2019une cellule brute, ils ne rel\u00e8vent pas du champ d\u2019application de la norme UL 1642. Une fois que les cellules nues sont soud\u00e9es sur des barres omnibus et int\u00e9gr\u00e9es \u00e0 un syst\u00e8me de gestion de batterie (BMS) \u00e0 l\u2019int\u00e9rieur d\u2019un bo\u00eetier, l\u2019unit\u00e9 assembl\u00e9e pr\u00e9sente des interactions \u00e9lectriques et thermiques multi-cellules qui n\u00e9cessitent une \u00e9valuation au niveau du pack.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-04dc27c7 auto-p elementor-widget elementor-widget-heading\" data-id=\"04dc27c7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">La seule reconnaissance de la norme UL 1642 au niveau des cellules ne suffit pas \u00e0 \u00e9tablir la conformit\u00e9 d'un module de batterie stationnaire fini. Les fabricants (EPC) doivent v\u00e9rifier les exigences applicables en mati\u00e8re d'\u00e9valuation au niveau du pack, d'homologation du syst\u00e8me et d'installation avant de soumettre l'\u00e9quipement \u00e0 l'approbation de l'autorit\u00e9 comp\u00e9tente (AHJ).<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-bda76b95 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"bda76b95\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Niveau d'\u00e9valuation 2 : Normes relatives aux packs et aux modules (certification UL 2054 par rapport \u00e0 la certification UL 1973)<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-dfbc4c49 auto-p elementor-widget elementor-widget-heading\" data-id=\"dfbc4c49\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Une fois les cellules soud\u00e9es sur les barres omnibus, raccord\u00e9es \u00e0 un syst\u00e8me de gestion de batterie (BMS) et scell\u00e9es \u00e0 l'int\u00e9rieur d'un bo\u00eetier, l'ensemble passe \u00e0 l'\u00e9tape d'\u00e9valuation de niveau 2. \u00c0 ce stade, les acheteurs B2B doivent faire la distinction entre les batteries portables \u00e0 usage domestique ou commercial (UL 2054) et les modules destin\u00e9s au stockage stationnaire, \u00e0 l'alimentation auxiliaire des v\u00e9hicules ou aux trains l\u00e9gers (UL 1973).<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7a08280f elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"7a08280f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Niveau 1 : \u00c9valuation des cellules brutes \u2192 UL 1642 (composant homologu\u00e9 - marquage UR)<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Appareils portables \/ \u00e0 usage domestique \/ \u00e0 usage professionnel \u2192 UL 2054<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">\u00c9quipements fixes \/ \u00e9quipements auxiliaires pour v\u00e9hicules \/ module LER \u2192 UL 1973<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-684327d0 auto-h3 elementor-widget elementor-widget-heading\" data-id=\"684327d0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">UL 2054 : Norme relative aux batteries portables et aux batteries \u00e0 usage commercial l\u00e9ger<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d9738470 auto-p elementor-widget elementor-widget-heading\" data-id=\"d9738470\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">La norme UL 2054 (Norme relative aux batteries \u00e0 usage domestique et professionnel) s'applique aux blocs-batteries portables primaires et secondaires utilis\u00e9s dans des \u00e9quipements \u00e0 usage domestique et professionnel, tels que les appareils \u00e9lectroniques portables, les outils \u00e9lectriques, les chariots m\u00e9dicaux et les appareils \u00e9lectrom\u00e9nagers portables. Plut\u00f4t que d'appliquer un profil d'essai unique et identique \u00e0 chaque bloc-batterie, la norme UL 2054 attribue des essais \u00e9lectriques (\u00e9valuations de surcharge, de d\u00e9charge forc\u00e9e, de court-circuit et de circuit \u00e0 d\u00e9faut unique), m\u00e9caniques (chute, choc et \u00e9crasement) et de conditionnement du bo\u00eetier (tels que le soulagement des contraintes thermiques ou de moulage pour les bo\u00eetiers en polym\u00e8re) en fonction de la composition chimique sp\u00e9cifique de la batterie, du mat\u00e9riau du bo\u00eetier et de la configuration du bloc-batterie.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5973cde9 auto-p elementor-widget elementor-widget-heading\" data-id=\"5973cde9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">L'utilisation d'un rapport relatif \u00e0 un syst\u00e8me portable conforme \u00e0 la norme UL 2054 dans le cadre d'un projet de stockage d'\u00e9nergie fixe et permanent peut entra\u00eener des difficult\u00e9s en mati\u00e8re d'autorisation lorsque l'installation rel\u00e8ve des r\u00e9glementations applicables au stockage fixe :<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-17a2f2d8 elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"17a2f2d8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Diff\u00e9rence de champ d'application par rapport aux normes applicables aux installations fixes : la norme UL 2054 porte sur les \u00e9quipements h\u00f4tes portables et mobiles, et non sur les syst\u00e8mes de stockage d'\u00e9nergie fixes raccord\u00e9s au r\u00e9seau ou int\u00e9gr\u00e9s \u00e0 des b\u00e2timents.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Champ d'application des essais de propagation : la norme UL 2054 n'inclut pas les proc\u00e9dures de confinement de la propagation en cas de d\u00e9faillance d'une cellule interne d'un module fixe et d'emballement thermique sp\u00e9cifi\u00e9es dans la norme UL 1973.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Applicabilit\u00e9 des codes et des exigences des autorit\u00e9s comp\u00e9tentes (AHJ) : L'acceptation d'un ensemble de batteries dans un b\u00e2timent commercial, une installation de t\u00e9l\u00e9communications ou une installation industrielle d\u00e9pend de la classification sp\u00e9cifique de l'\u00e9quipement, des seuils de capacit\u00e9, des codes \u00e9lectriques et de s\u00e9curit\u00e9 incendie en vigueur (tels que l'article 706 du NEC, la norme NFPA 855 ou le Code international de s\u00e9curit\u00e9 incendie) et des exigences locales des autorit\u00e9s comp\u00e9tentes (AHJ).<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9ce26c8d auto-h3 elementor-widget elementor-widget-heading\" data-id=\"9ce26c8d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Certification UL 1973 : modules fixes, auxiliaires pour v\u00e9hicules et modules pour le transport ferroviaire \u00e9lectrique l\u00e9ger<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-fbf265cc auto-p elementor-widget elementor-widget-heading\" data-id=\"fbf265cc\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">La norme UL 1973 (Norme relative aux batteries destin\u00e9es \u00e0 des applications fixes, d'alimentation auxiliaire des v\u00e9hicules et de transport ferroviaire l\u00e9ger) est l'une des principales normes applicables aux modules, blocs et racks de batteries dans trois cat\u00e9gories d'applications industrielles, \u00e9valu\u00e9es en fonction de la cat\u00e9gorie de produit et des exigences du projet :<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-328fc6ef elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"328fc6ef\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Stockage d'\u00e9nergie stationnaire : baies BESS commerciales, batteries de secours pour t\u00e9l\u00e9communications de 48 V\/51,2 V, cha\u00eenes de batteries pour r\u00e9seaux \u00e9lectriques et armoires d'alimentation sans coupure (UPS) pour centres de donn\u00e9es.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Alimentation auxiliaire des v\u00e9hicules : batteries auxiliaires alimentant les \u00e9quipements non li\u00e9s \u00e0 la propulsion, les syst\u00e8mes de chauffage, de ventilation et de climatisation (CVC) ainsi que les \u00e9quipements \u00e9lectroniques dans les v\u00e9hicules utilitaires.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Light Electric Rail (LER) : ensembles de batteries destin\u00e9s aux applications ferroviaires et de transport urbain.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9c9afc3f auto-p elementor-widget elementor-widget-heading\" data-id=\"9c9afc3f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">L'obtention de la certification UL 1973 implique des \u00e9valuations \u00e9lectriques, m\u00e9caniques et relatives aux d\u00e9faillances des cellules, d\u00e9finies par les clauses de la norme applicable et l'usage pr\u00e9vu :<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1583f923 elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"1583f923\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Circuit de protection et \u00e9valuation des d\u00e9fauts isol\u00e9s :<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">\u2014 Les ing\u00e9nieurs du laboratoire simulent des conditions de d\u00e9faut unique (telles que des d\u00e9fauts simul\u00e9s au niveau d'un dispositif de commutation, d'un capteur ou d'une piste de d\u00e9tection) tandis que la batterie fonctionne dans des conditions anormales de surcharge, de d\u00e9charge excessive ou de courant \u00e9lev\u00e9.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">\u2014 En cas de d\u00e9faut unique, le syst\u00e8me de protection de la batterie doit maintenir l'ensemble dans les limites de fonctionnement s\u00fbres ou le faire passer \u00e0 un \u00e9tat s\u00fbr, conform\u00e9ment \u00e0 l'architecture de protection d\u00e9finie par le fabricant et aux exigences des normes applicables.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Tension di\u00e9lectrique de tenue et r\u00e9sistance d'isolement :<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">\u2014 Les modules et cha\u00eenes de batteries (par exemple, les racks commerciaux fonctionnant dans des plages de tension repr\u00e9sentatives telles que 676 V \u00e0 936 V CC ou les cha\u00eenes de r\u00e9seau \u00e0 1 331,2 V CC) sont soumis \u00e0 des essais de r\u00e9sistance di\u00e9lectrique en courant alternatif ou continu (hi-pot) et de r\u00e9sistance d\u2019isolement, les tensions d\u2019essai exactes \u00e9tant calcul\u00e9es \u00e0 partir de la tension nominale du syst\u00e8me de l\u2019\u00e9quipement selon les formules de la norme UL 1973.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">\u00c9valuation des d\u00e9faillances internes des cellules et de leur propagation :<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">\u2014 La d\u00e9faillance est provoqu\u00e9e dans une cellule cible du module \u00e0 l'aide d'une m\u00e9thode de d\u00e9clenchement conforme aux normes et adapt\u00e9e \u00e0 la conception de la cellule et du module.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">\u2014 La conformit\u00e9 est \u00e9valu\u00e9e au regard des crit\u00e8res sp\u00e9cifiques de r\u00e9ussite ou d'\u00e9chec et des voies de mise en conformit\u00e9 d\u00e9finis dans l'\u00e9dition et l'annexe de la norme UL 1973 applicables \u00e0 l'environnement d'installation pr\u00e9vu.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">\u00c9valuations de l'int\u00e9grit\u00e9 m\u00e9canique :<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">\u2014 Selon que l'ensemble est class\u00e9 pour une utilisation fixe, comme \u00e9quipement auxiliaire de v\u00e9hicule ou pour le transport ferroviaire l\u00e9ger \u00e9lectrique, et selon le mode de montage du bo\u00eetier, la norme UL 1973 applique les clauses correspondantes relatives \u00e0 l'\u00e9crasement, aux chocs, aux secousses ou aux vibrations.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8473b30f elementor-tablet-align-center elementor-align-center auto-cta elementor-widget elementor-widget-button\" data-id=\"8473b30f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"#elementor-action%3Aaction%3Dpopup%3Aopen%26settings%3DeyJpZCI6Ijk0OCIsInRvZ2dsZSI6ZmFsc2V9\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Contactez-nous pour obtenir un examen du champ d'application de la certification UL sp\u00e9cifique \u00e0 un mod\u00e8le<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-563f680b auto-h2 elementor-widget elementor-widget-heading\" data-id=\"563f680b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Niveau d'\u00e9valuation 3 : \u00c9valuation des syst\u00e8mes de contr\u00f4le et de la s\u00e9curit\u00e9 fonctionnelle (UL 991 et UL 1998)<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-cd6cd0db auto-p elementor-widget elementor-widget-heading\" data-id=\"cd6cd0db\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Dans le cadre des enqu\u00eates men\u00e9es au titre des normes UL 1973 ou UL 9540, l'\u00e9valuation des composants \u00e9lectroniques et des logiciels du syst\u00e8me de gestion de batterie (BMS) constitue une \u00e9tape technique importante d\u00e8s lors que des commandes actives assurent des fonctions de protection essentielles \u00e0 la s\u00e9curit\u00e9.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-02641a4c auto-h3 elementor-widget elementor-widget-heading\" data-id=\"02641a4c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Comprendre le champ d'application des normes UL 991 et UL 1998<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b45d7568 auto-p elementor-widget elementor-widget-heading\" data-id=\"b45d7568\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Les normes UL 991 et UL 1998 constituent des normes techniques r\u00e9gissant la conception et l'\u00e9valuation des mat\u00e9riels et logiciels de commande li\u00e9s \u00e0 la s\u00e9curit\u00e9, et non deux certificats de certification distincts et autonomes que chaque syst\u00e8me de gestion des b\u00e2timents (BMS) doit obtenir s\u00e9par\u00e9ment. Que ce soit la norme UL 991, la norme UL 1998 ou d\u2019autres normes de s\u00e9curit\u00e9 fonctionnelle reconnues (telles que la norme UL 60730-1, IEC 61508 ou ISO 13849) s\u2019appliquent d\u00e9pend des fonctions de s\u00e9curit\u00e9 sp\u00e9cifiques attribu\u00e9es au BMS, de l\u2019architecture mat\u00e9rielle de protection et des crit\u00e8res d\u2019\u00e9valuation de la norme de r\u00e9f\u00e9rence (telle que UL 1973 ou UL 9540) :<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9440fb07 elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"9440fb07\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Norme UL 991 (Essais relatifs aux commandes de s\u00e9curit\u00e9 utilisant des dispositifs \u00e0 semi-conducteurs) :<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">\u2014 \u00c9value les syst\u00e8mes de commande li\u00e9s \u00e0 la s\u00e9curit\u00e9 utilisant des dispositifs \u00e0 semi-conducteurs lorsque ces circuits assurent des fonctions de protection primaires.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">\u2014 R\u00e9alise des \u00e9valuations des contraintes environnementales, \u00e9lectriques et \u00e9lectromagn\u00e9tiques (telles que les d\u00e9charges \u00e9lectrostatiques, les champs \u00e9lectromagn\u00e9tiques rayonn\u00e9s, les transitoires rapides, les variations de tension d'alimentation ou la d\u00e9rive thermique), s\u00e9lectionn\u00e9es conform\u00e9ment aux dispositions des normes applicables et \u00e0 la structure du contr\u00f4leur.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">\u2014 Effectue une analyse des d\u00e9faillances des composants et une simulation de d\u00e9faillances afin de v\u00e9rifier que le syst\u00e8me de commande maintient la s\u00e9curit\u00e9 ou passe \u00e0 un \u00e9tat de s\u00e9curit\u00e9 d\u00e9fini, d\u00e9termin\u00e9 par la fonction de s\u00e9curit\u00e9 sp\u00e9cifique.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Norme UL 1998 (Logiciels dans les composants programmables) :<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">\u2014 \u00c9value les logiciels programmables et les micrologiciels embarqu\u00e9s (quel que soit le langage de programmation utilis\u00e9) lorsque la logique logicielle commande des fonctions de protection li\u00e9es \u00e0 la s\u00e9curit\u00e9.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">\u2014 Examine l'architecture logicielle et les mesures de contr\u00f4le des d\u00e9faillances, qui peuvent inclure des techniques de conception telles que les temporisateurs de surveillance, les contr\u00f4les d'int\u00e9grit\u00e9 de la m\u00e9moire et des registres (par exemple, le CRC), l'ex\u00e9cution d\u00e9terministe des t\u00e2ches et la gestion d\u00e9fensive des d\u00e9faillances de communication, en fonction de la cat\u00e9gorie du logiciel et de l'analyse de s\u00e9curit\u00e9.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-187250cc auto-h3 elementor-widget elementor-widget-heading\" data-id=\"187250cc\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Comment l'architecture du syst\u00e8me de gestion de la batterie (BMS) influence l'\u00e9valuation de la s\u00e9curit\u00e9 fonctionnelle<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b93b448f auto-p elementor-widget elementor-widget-heading\" data-id=\"b93b448f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Conform\u00e9ment aux normes UL 1973 et UL 9540, le champ d'application de l'\u00e9valuation des contr\u00f4les d\u00e9pend de la mani\u00e8re dont les coupures de protection primaires et secondaires sont r\u00e9parties entre les composants passifs, le mat\u00e9riel discret et les logiciels programmables. Le tableau 2 pr\u00e9sente les \u00e9l\u00e9ments \u00e0 prendre en compte lors de l'\u00e9valuation des architectures de protection courantes des syst\u00e8mes de gestion de batterie (BMS).<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-51dba80f auto-h3 elementor-widget elementor-widget-heading\" data-id=\"51dba80f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Tableau 2 : Architecture de protection du syst\u00e8me de gestion de la batterie (BMS) et \u00e9l\u00e9ments \u00e0 prendre en compte lors de l'\u00e9valuation<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-83e48fb8 auto-table elementor-widget elementor-widget-text-editor\" data-id=\"83e48fb8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"cea-table-wrap\"><table><thead><tr><th>Architecture de protection<\/th><th>M\u00e9thode de s\u00e9lection primaire<\/th><th>\u00c9l\u00e9ments \u00e0 prendre en compte lors de l'\u00e9valuation du potentiel<\/th><\/tr><\/thead><tbody><tr><td>Fusible passif et coupe-circuit thermique<\/td><td>\u00c9l\u00e9ment de fusion \u00e9lectrom\u00e9canique<\/td><td>\u00c9valu\u00e9 conform\u00e9ment aux normes applicables relatives aux fusibles ou aux dispositifs thermiques des composants (par exemple, UL 248) ; l'audit logiciel ne s'applique pas au chemin passif<\/td><\/tr><tr><td>Seuil mat\u00e9riel non programmable<\/td><td>Comparateurs analogiques discrets et logique mat\u00e9rielle<\/td><td>Analyse des d\u00e9fauts du mat\u00e9riel de commande \u00e0 semi-conducteurs et clauses applicables en mati\u00e8re de CEM et d'environnement (telles que la norme UL 991 ou une norme \u00e9quivalente)<\/td><\/tr><tr><td>Coupure du contr\u00f4leur programmable<\/td><td>Micrologiciel de microcontr\u00f4leur pilotant des dispositifs de commutation<\/td><td>Analyse des d\u00e9faillances mat\u00e9rielles et \u00e9valuation des logiciels programmables (telles que les normes UL 991 et UL 1998, ou leurs \u00e9quivalents reconnus comme UL 60730-1 \/ CEI 61508), en fonction des fonctions de s\u00e9curit\u00e9 attribu\u00e9es<\/td><\/tr><\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-807403c8 auto-p elementor-widget elementor-widget-heading\" data-id=\"807403c8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\"><strong>Conseil technique \u00e0 l'attention des acheteurs OEM\/ODM :<\/strong> Lors de l'approvisionnement en blocs-batteries sur mesure ou de l'int\u00e9gration de contr\u00f4leurs BMS tiers, v\u00e9rifiez aupr\u00e8s du fournisseur comment les coupures de s\u00e9curit\u00e9 primaires et secondaires sont r\u00e9parties entre le mat\u00e9riel et le logiciel, et v\u00e9rifiez quelle voie d'\u00e9valuation de la s\u00e9curit\u00e9 fonctionnelle s'applique dans le cadre de l'\u00e9tude vis\u00e9e par les normes UL 1973 ou UL 9540.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-98c57978 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"98c57978\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Niveau d'\u00e9valuation 4 : \u00c9valuation de la s\u00e9curit\u00e9 au niveau du syst\u00e8me (UL 9540 et certification UL 9540)<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-916953e6 auto-p elementor-widget elementor-widget-heading\" data-id=\"916953e6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">L'association d'un ensemble de batteries conforme \u00e0 la norme UL 1973 \u00e0 un onduleur conforme \u00e0 la norme UL 1741 n\u00e9cessite de v\u00e9rifier que la configuration compl\u00e8te du syst\u00e8me respecte les codes d'installation applicables et les exigences d'homologation au niveau du syst\u00e8me. Dans les juridictions appliquant la norme NFPA 855, le Code international de pr\u00e9vention des incendies (IFC) ou l'article 706 du NEC, les autorit\u00e9s comp\u00e9tentes \u00e9valuent si le syst\u00e8me int\u00e9gr\u00e9 dispose d'une homologation UL 9540 applicable.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f65f064c auto-h3 elementor-widget elementor-widget-heading\" data-id=\"f65f064c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Qu'est-ce que la norme UL 9540 (syst\u00e8mes et \u00e9quipements de stockage d'\u00e9nergie) ?<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-291dd294 auto-p elementor-widget elementor-widget-heading\" data-id=\"291dd294\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">La norme UL 9540 \u00e9value l'ensemble du syst\u00e8me de stockage d'\u00e9nergie en tant que produit int\u00e9gr\u00e9, comprenant les modules de batterie, les \u00e9quipements de conversion de puissance, les syst\u00e8mes de commande, les fonctions de protection et tout autre composant concern\u00e9. Les exigences sp\u00e9cifiques en mati\u00e8re d'\u00e9valuation d\u00e9pendent de l'architecture du syst\u00e8me, de l'application pr\u00e9vue et de l'\u00e9dition de la norme applicable.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8e9f50ff auto-p elementor-widget elementor-widget-heading\" data-id=\"8e9f50ff\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Dans le cadre d'une enqu\u00eate de certification UL 9540, les ing\u00e9nieurs d'un laboratoire d'essais reconnu au niveau national (NRTL) \u00e9valuent la s\u00e9curit\u00e9 au niveau du syst\u00e8me dans tous les domaines concern\u00e9s :<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3a4a11b1 elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"3a4a11b1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Coordination de la charge, de la d\u00e9charge et des commandes : v\u00e9rifie que le sous-syst\u00e8me de batterie, les \u00e9quipements de conversion de puissance et les commandes du syst\u00e8me fonctionnent dans les limites nominales de tension, de courant et de temp\u00e9rature, tant en conditions normales qu\u2019anormales de fonctionnement.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Communication et r\u00e9ponse en \u00e9tat de s\u00e9curit\u00e9 : \u00e9value la mani\u00e8re dont le syst\u00e8me int\u00e9gr\u00e9 r\u00e9agit \u00e0 une perte de communication de contr\u00f4le critique entre les sous-syst\u00e8mes, en v\u00e9rifiant que le syst\u00e8me passe \u00e0 un \u00e9tat de fonctionnement s\u00fbr ou d'arr\u00eat d\u00e9fini, conform\u00e9ment \u00e0 son analyse de s\u00e9curit\u00e9 et aux exigences normatives.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Coordination \u00e9lectrique et en cas de court-circuit : \u00e9value les contributions au courant de d\u00e9faut provenant des cha\u00eenes de batteries et des \u00e9quipements de conversion de puissance, en fonction de la topologie r\u00e9elle du circuit et de l'architecture de coordination des dispositifs de protection.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Gestion thermique et \u00e9valuation des bo\u00eetiers : \u00c9value les sous-syst\u00e8mes de refroidissement dans les conditions de fonctionnement nominales d\u00e9finies par le plan d'essais de certification, et \u00e9value les bo\u00eetiers d'ext\u00e9rieur ou d'int\u00e9rieur par rapport \u00e0 la norme de classification d\u00e9clar\u00e9e (en notant que les classifications NEMA telles que NEMA 3R et les indices de protection contre les infiltrations de la CEI tels que IP54 ou IP55 suivent des crit\u00e8res d'essai diff\u00e9rents et ne peuvent pas \u00eatre consid\u00e9r\u00e9s comme identiques).<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Interfaces de d\u00e9tection d'incendie et d'att\u00e9nuation des risques : \u00e9value les interfaces de d\u00e9tection de gaz, de d\u00e9tection de fum\u00e9e\/thermique, de ventilation ou d'extinction d'incendie lorsqu'elles sont incluses dans la conception du syst\u00e8me ou requises pour la cat\u00e9gorie d'installation pr\u00e9vue (par exemple, les interverrouillages CVC sp\u00e9cifiques au projet ou les syst\u00e8mes d'extinction \u00e0 agent propre tels que le Novec 1230 ou les unit\u00e9s \u00e0 a\u00e9rosol).<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-55a1342e auto-h3 elementor-widget elementor-widget-heading\" data-id=\"55a1342e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">UL 9540 vs UL 9540A : mises \u00e0 jour des \u00e9ditions et seuils r\u00e9glementaires<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3d36de9b auto-p elementor-widget elementor-widget-heading\" data-id=\"3d36de9b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Les d\u00e9veloppeurs de projets confondent souvent la norme UL 9540 avec la norme UL 9540A. Bien que leurs num\u00e9ros soient similaires, ces normes remplissent des r\u00f4les r\u00e9glementaires distincts :<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e883d3c6 elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"e883d3c6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">La norme UL 9540 est une norme de s\u00e9curit\u00e9 des produits au niveau du syst\u00e8me qui donne lieu \u00e0 l'apposition d'un marquage de certification sur les \u00e9quipements de stockage d'\u00e9nergie conformes.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">La norme UL 9540A (M\u00e9thode d'essai pour l'\u00e9valuation de la propagation d'un incendie d\u00fb \u00e0 un emballement thermique dans les syst\u00e8mes de stockage d'\u00e9nergie par batterie) est une m\u00e9thode d'essai au feu qui permet d'obtenir des donn\u00e9es techniques d'essai plut\u00f4t qu'un certificat de conformit\u00e9 indiquant si le produit est conforme ou non.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d1e00531 auto-p elementor-widget elementor-widget-heading\" data-id=\"d1e00531\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Les ing\u00e9nieurs charg\u00e9s d'examiner la documentation relative aux essais selon la norme UL 9540A doivent \u00e9galement tenir compte des diff\u00e9rences entre les diff\u00e9rentes \u00e9ditions de la norme, plut\u00f4t que de partir du principe que chaque rapport suit une s\u00e9quence identique en quatre \u00e9tapes :<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4d51a25f elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"4d51a25f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">UL 9540A, 5e \u00e9dition : essais structur\u00e9s r\u00e9partis sur quatre niveaux successifs : niveau cellule, niveau module, niveau unit\u00e9 et niveau installation.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">UL 9540A, 6e \u00e9dition : conserve les essais d'incendie \u00e0 grande \u00e9chelle au niveau des cellules, des modules et des installations, tout en r\u00e9visant l'applicabilit\u00e9 et le champ d'application des essais au niveau des unit\u00e9s. La poursuite des essais vers des niveaux sup\u00e9rieurs d\u00e9pend des r\u00e9sultats obtenus aux niveaux pr\u00e9c\u00e9dents et des param\u00e8tres d'installation pr\u00e9vus.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-17d26c05 auto-p elementor-widget elementor-widget-heading\" data-id=\"17d26c05\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Les rapports d'essai UL 9540A documentent la composition des gaz \u00e9mis par les cellules, le confinement de l'emballement thermique des modules et le comportement de propagation de la chaleur et des flammes, \u00e0 des fins de v\u00e9rification de la conformit\u00e9 aux normes. Les seuils de capacit\u00e9 \u00e9nerg\u00e9tique applicables, les mesures de protection contre l'incendie, les distances de s\u00e9paration et les exigences d'installation d\u00e9pendent des \u00e9ditions adopt\u00e9es de la norme NFPA 855 et du code de pr\u00e9vention des incendies (y compris les mises \u00e0 jour jusqu'\u00e0 l'\u00e9dition 2026 de la norme NFPA 855), de la composition chimique de la batterie, du type d'installation et des exigences locales de l'autorit\u00e9 comp\u00e9tente (AHJ).<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6a925a77 auto-image elementor-widget elementor-widget-image\" data-id=\"6a925a77\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"1536\" height=\"1024\" src=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/ul-four-tier-compliance-pyramid-1642-1973-9540-v2-1536x1024.webp\" class=\"attachment-1536x1536 size-1536x1536 wp-image-7929\" alt=\"Pyramide de conformit\u00e9 UL \u00e0 quatre niveaux pr\u00e9sentant les cellules UL 1642, les modules fixes UL 1973, les syst\u00e8mes de gestion de batterie (BMS) UL 991 et UL 1998, ainsi que l&#039;\u00e9valuation compl\u00e8te du syst\u00e8me ESS selon la norme UL 9540\" srcset=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/ul-four-tier-compliance-pyramid-1642-1973-9540-v2-1536x1024.webp 1536w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/ul-four-tier-compliance-pyramid-1642-1973-9540-v2-300x200.webp 300w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/ul-four-tier-compliance-pyramid-1642-1973-9540-v2-1024x683.webp 1024w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/ul-four-tier-compliance-pyramid-1642-1973-9540-v2-768x512.webp 768w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/ul-four-tier-compliance-pyramid-1642-1973-9540-v2-18x12.webp 18w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/ul-four-tier-compliance-pyramid-1642-1973-9540-v2-600x400.webp 600w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/ul-four-tier-compliance-pyramid-1642-1973-9540-v2.webp 1920w\" sizes=\"(max-width: 1536px) 100vw, 1536px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1c70b901 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"1c70b901\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">R\u00e9alit\u00e9 juridique pour l'acheteur : reconnaissance UL, homologation UL et champ d'application NRTL<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-bce50aa7 auto-p elementor-widget elementor-widget-heading\" data-id=\"bce50aa7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Lorsqu'elles examinent la documentation des fournisseurs concernant les batteries au lithium homologu\u00e9es UL, les \u00e9quipes charg\u00e9es des achats doivent faire la distinction entre la reconnaissance des composants et l'homologation du produit, et v\u00e9rifier les limites de l'accr\u00e9ditation des laboratoires.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4537afec auto-h3 elementor-widget elementor-widget-heading\" data-id=\"4537afec\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Rep\u00e9rer les all\u00e9gations trompeuses des fournisseurs : le label \u00ab UR \u00bb face aux labels de r\u00e9f\u00e9rencement<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d754effd auto-p elementor-widget elementor-widget-heading\" data-id=\"d754effd\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Les fournisseurs pr\u00e9sentent parfois des certificats relatifs aux composants pour attester de la conformit\u00e9 du syst\u00e8me. Les acheteurs doivent v\u00e9rifier le marquage exact et le champ d'application du certificat :<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a428f82e elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"a428f82e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Le marquage UR (composant homologu\u00e9 UL) :<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">\u2014 Repr\u00e9sent\u00e9 par un \" U \" associ\u00e9 \u00e0 un \" R \" \u00e0 l'envers.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">\u2014 Indique qu\u2019un composant (tel qu\u2019une cellule nue conforme \u00e0 la norme UL 1642 ou un relais de protection interne) a fait l\u2019objet d\u2019une \u00e9valuation en vue de son int\u00e9gration en usine dans un \u00e9quipement complet, dans des conditions d\u2019acceptabilit\u00e9 sp\u00e9cifi\u00e9es.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">\u2014 La reconnaissance des composants ne suffit pas \u00e0 elle seule \u00e0 \u00e9tablir qu\u2019un module ou un bo\u00eetier de batterie fini est homologu\u00e9 pour une installation autonome sur site.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Marques de certification des produits (telles que la certification UL) :<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">\u2014 G\u00e9n\u00e9ralement repr\u00e9sent\u00e9 par UL Solutions sous la forme du symbole \" UL \" entour\u00e9 d'un cercle, accompagn\u00e9 de la mention \" LISTED \" et d'un identifiant de d\u00e9livrance\/contr\u00f4le, bien que les formats sp\u00e9cifiques des marques varient selon le programme de certification et l'organisme \u00e9metteur.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">\u2014 Indique que des \u00e9chantillons repr\u00e9sentatifs d'un produit ou d'un syst\u00e8me complet (tel qu'un module de batterie conforme \u00e0 la norme UL 1973 ou un syst\u00e8me de stockage d'\u00e9nergie conforme \u00e0 la norme UL 9540) ont \u00e9t\u00e9 \u00e9valu\u00e9s en vue d'une installation sur site dans le cadre de l'homologation.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1b895134 auto-h3 elementor-widget elementor-widget-heading\" data-id=\"1b895134\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Comprendre le champ d'application des NRTL de l'OSHA et leur acceptation par les autorit\u00e9s locales comp\u00e9tentes (AHJ)<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d5773698 auto-p elementor-widget elementor-widget-heading\" data-id=\"d5773698\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">En vertu de la r\u00e9glementation 29 CFR 1910.7 de l\u2019Administration am\u00e9ricaine de la s\u00e9curit\u00e9 et de la sant\u00e9 au travail (OSHA), l\u2019OSHA accr\u00e9dite des laboratoires d\u2019essais reconnus au niveau national (NRTL) pour tester et certifier les \u00e9quipements utilis\u00e9s sur le lieu de travail relevant des normes de s\u00e9curit\u00e9 de l\u2019OSHA. Lors de l\u2019\u00e9valuation des certificats d\u00e9livr\u00e9s par diff\u00e9rents laboratoires, les \u00e9quipes charg\u00e9es des achats doivent v\u00e9rifier deux aspects juridiques :<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0a3d1276 elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"0a3d1276\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">La reconnaissance NRTL est sp\u00e9cifique \u00e0 chaque norme et n'est pas universelle :<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">\u2014 NRTL est un programme d'accr\u00e9ditation plut\u00f4t qu'un simple label de certification.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">\u2014 Chaque organisme accr\u00e9dit\u00e9 (tel que UL Solutions, Intertek\/ETL, CSA Group, T\u00dcV Rheinland, T\u00dcV S\u00dcD ou SGS North America) n\u2019est reconnu par l\u2019OSHA que pour les normes d\u2019essai sp\u00e9cifiques figurant dans le champ d\u2019application officiel de la reconnaissance de ce laboratoire. Le fait de d\u00e9tenir le statut NRTL n'autorise pas un laboratoire \u00e0 certifier toutes les cat\u00e9gories de produits ni toutes les normes UL.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Accr\u00e9ditation OSHA vs. agr\u00e9ment des autorit\u00e9s locales comp\u00e9tentes (AHJ) et des compagnies d'assurance :<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">\u2014 La certification des lieux de travail par l\u2019OSHA, l\u2019application des codes locaux du b\u00e2timent et de pr\u00e9vention des incendies, ainsi que la souscription d\u2019assurances pour les biens immobiliers commerciaux rel\u00e8vent de comp\u00e9tences distinctes.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-bd065b37 auto-p elementor-widget elementor-widget-heading\" data-id=\"bd065b37\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\"><strong>Limite d'acceptation NRTL :<\/strong> Une certification ETL, CSA ou d\u00e9livr\u00e9e par un autre organisme NRTL peut constituer une alternative valable \u00e0 une certification UL lorsque l'organisme \u00e9metteur est reconnu pour la cat\u00e9gorie de produit et la norme d'essai concern\u00e9es, et que la certification couvre pr\u00e9cis\u00e9ment la configuration de l'\u00e9quipement. Il convient toutefois de v\u00e9rifier que cette certification est bien accept\u00e9e par l'autorit\u00e9 comp\u00e9tente locale (AHJ) et l'assureur du projet.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-fdc5d7f9 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"fdc5d7f9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Le processus de test des batteries de l'UL : protocoles de mise \u00e0 l'\u00e9preuve et donn\u00e9es sur les cellules hybrides solide-liquide<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6a56f629 auto-p elementor-widget elementor-widget-heading\" data-id=\"6a56f629\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Comprendre comment les essais de batteries UL \u00e9valuent les contraintes \u00e9lectriques, thermiques et m\u00e9caniques aide les ing\u00e9nieurs \u00e0 interpr\u00e9ter avec pr\u00e9cision les r\u00e9sum\u00e9s des essais fournis par les fabricants, sans confondre des normes d'essai distinctes.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3538df73 auto-h3 elementor-widget elementor-widget-heading\" data-id=\"3538df73\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">En quoi les protocoles de gestion des abus diff\u00e8rent-ils d'une norme \u00e0 l'autre ?<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-fb83b2fb auto-p elementor-widget elementor-widget-heading\" data-id=\"fb83b2fb\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Les normes relatives aux essais sur les cellules, les modules et les essais au feu pr\u00e9voient des limites d'essai et des m\u00e9thodes de d\u00e9clenchement distinctes, plut\u00f4t qu'une proc\u00e9dure unique regroupant ces \u00e9l\u00e9ments :<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-18e22018 elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"18e22018\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Essais de surcharge au niveau des cellules et des modules : les essais de charge anormale au niveau des cellules pr\u00e9vus par la norme UL 1642 s'appliquent aux cellules primaires, tandis que les essais de surcharge au niveau des modules pr\u00e9vus par la norme UL 1973 \u00e9valuent des packs rechargeables assembl\u00e9s dans des conditions de d\u00e9faillance unique du BMS, jusqu'aux limites de tension ou de courant de charge sp\u00e9cifi\u00e9es.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Essais de court-circuit externe : tant la norme UL 1642 (au niveau de la borne nue de la cellule) que la norme UL 1973 (au niveau de la sortie du module ou du pack) pr\u00e9voient des circuits de d\u00e9faut \u00e0 faible imp\u00e9dance utilisant des valeurs de r\u00e9sistance et des configurations de dispositifs de protection d\u00e9finies par les clauses respectives de ces normes.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Propagation de l'emballement thermique vs essais au feu : La norme UL 1973 \u00e9value le confinement d\u2019une d\u00e9faillance d\u2019une seule cellule au sein d\u2019un module, tandis que la norme UL 9540A \u00e9value la propagation d\u2019un incendie d\u00fb \u00e0 un emballement thermique et la production de gaz \u00e0 l\u2019aide de m\u00e9thodes d\u2019amor\u00e7age (telles que des sources de chaleur externes, une surcharge, la p\u00e9n\u00e9tration d\u2019un clou ou d\u2019autres d\u00e9clencheurs) autoris\u00e9es par l\u2019\u00e9dition applicable de la norme, ainsi que la r\u00e9ponse des cellules.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ae7a00fd auto-p elementor-widget elementor-widget-heading\" data-id=\"ae7a00fd\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Dans les cellules lithium-ion \u00e0 \u00e9lectrolyte liquide classiques, les solvants carbonates organiques volatils peuvent se vaporiser et d\u00e9gager des m\u00e9langes de gaz inflammables lorsque les temp\u00e9ratures internes sont \u00e9lev\u00e9es ; le moment exact o\u00f9 ce d\u00e9gagement commence et le volume de gaz d\u00e9gag\u00e9 d\u00e9pendent de la formulation sp\u00e9cifique de l'\u00e9lectrolyte, de l'\u00e9tat de charge et de la structure de la cellule.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-15ac76e2 auto-h3 elementor-widget elementor-widget-heading\" data-id=\"15ac76e2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Caract\u00e9ristiques techniques et donn\u00e9es des essais de r\u00e9sistance aux conditions extr\u00eames de la cellule hybride solide-liquide MegSolid<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8ec5226e auto-p elementor-widget elementor-widget-heading\" data-id=\"8ec5226e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Comme indiqu\u00e9 dans les fiches techniques sp\u00e9cifiques aux cellules de MegSolid, les cellules prismatiques hybrides solide-liquide de stockage d'\u00e9nergie SHS180-314Ah et SHS165-280Ah int\u00e8grent <strong><a href=\"https:\/\/www.solidess.com\/fr\/bess\/technologie-des-batteries-a-etat-solide\/\" target=\"_blank\" style=\"color:#61ce70\">technologie des \u00e9lectrolytes nano \u00e0 l'\u00e9tat solide<\/a><\/strong> con\u00e7u pour r\u00e9duire la teneur en solvant liquide libre et limiter les r\u00e9actions secondaires ind\u00e9sirables.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-757a9333 auto-p elementor-widget elementor-widget-heading\" data-id=\"757a9333\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Le tableau 3 pr\u00e9sente les param\u00e8tres techniques ainsi que les r\u00e9sultats des tests de r\u00e9f\u00e9rence, distingu\u00e9s au niveau des cellules et au niveau des modules, tels qu'ils figurent dans les fiches techniques officielles des mod\u00e8les SHS180-314Ah et SHS165-280Ah.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-bc1f7115 auto-h3 elementor-widget elementor-widget-heading\" data-id=\"bc1f7115\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Tableau 3 : Caract\u00e9ristiques techniques de la cellule hybride solide-liquide MegSolid et r\u00e9sultats des tests de performance publi\u00e9s<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d8e70f7a auto-table elementor-widget elementor-widget-text-editor\" data-id=\"d8e70f7a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"cea-table-wrap\"><table><thead><tr><th>Param\u00e8tre \/ Cat\u00e9gorie de test<\/th><th>Cellule MegSolid SHS180-314 Ah<\/th><th>Cellule MegSolid SHS165-280 Ah<\/th><\/tr><\/thead><tbody><tr><td>Capacit\u00e9 nominale et tension nominale<\/td><td>314 Ah \/ 3,2 V (1 004,8 Wh calcul\u00e9s ; 1 005 Wh indiqu\u00e9s dans la fiche technique)<\/td><td>Classe 280 Ah \/ 3,2 V<\/td><\/tr><tr><td>Densit\u00e9 \u00e9nerg\u00e9tique et masse<\/td><td>180 Wh\/kg \/ 390 Wh\/L (masse des cellules : 5,60 \u00b1 0,1 kg)<\/td><td>Cat\u00e9gorie 165 Wh\/kg (~350\u2013365 Wh\/L)<\/td><\/tr><tr><td>R\u00e9sistance interne et rendement des cellules<\/td><td>CA : 0,18 \u00b1 0,03 m\u03a9 \/ CC : 0,4 \u00b1 0,1 m\u03a9 ; rendement \u00e9nerg\u00e9tique de la cellule \u2265 94,5 %<\/td><td>Interface \u00e0 faible imp\u00e9dance entre un nano\u00e9lectrolyte et un mat\u00e9riau \u00e0 l'\u00e9tat solide<\/td><\/tr><tr><td>Dur\u00e9e de vie nominale et \u00e9tat en fin de vie<\/td><td>6 000 cycles jusqu'\u00e0 un SOH \u2265 80 % (\u00e0 0,5 P\/0,5 P, 100 % de profondeur de d\u00e9charge)<\/td><td>\u2265 8 000 cycles jusqu'\u00e0 \u2265 70 % de SOH (\u00e0 0,5 P\/0,5 P, 100 % de DoD, temp\u00e9rature ambiante)<\/td><\/tr><tr><td>Essai de p\u00e9n\u00e9tration des clous au niveau cellulaire<\/td><td>P\u00e9n\u00e9tration d'un clou en acier de 5 mm : aucune instabilit\u00e9 thermique dans les conditions d'essai<\/td><td>V\u00e9rifier le rapport d'essai de fixation des cellules sp\u00e9cifique au mod\u00e8le ainsi que les conditions d'\u00e9chantillonnage<\/td><\/tr><tr><td>Essais thermiques et de court-circuit au niveau des cellules<\/td><td>M\u00e9thode GB\/T 36276-2023 : temp\u00e9rature de d\u00e9clenchement de l'emballement thermique \u2265 110 \u00b0C ; \u0394T sur grande surface en cas de court-circuit externe &lt; 10 \u00b0C<\/td><td>M\u00e9thode GB\/T 36276-2018 : temp\u00e9rature de surface de la cellule &gt; 120 \u00b0C pendant l'essai d'emballement thermique<\/td><\/tr><tr><td>Essai de surcharge au niveau du module 1C<\/td><td>V\u00e9rifier le rapport de surcharge au niveau des modules en fonction de la configuration des packs<\/td><td>Test de surcharge du module 1C du 1P52S : pas de fum\u00e9e, pas d'incendie, pas d'explosion<\/td><\/tr><tr><td>Normes mentionn\u00e9es sur la fiche de cellule<\/td><td>M\u00e9thodes d'essai GB\/T 36276-2023<\/td><td>GB\/T 36276-2018, UL 1642, UL 1973, UL 9540A, CEI 62619, RoHS, UN 38.3<\/td><\/tr><\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-dd307031 auto-p elementor-widget elementor-widget-heading\" data-id=\"dd307031\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Remarques techniques concernant la v\u00e9rification des essais de cellules et de modules signal\u00e9s :<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-fadfa88c elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"fadfa88c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Limites d'essai distinctes : essais de p\u00e9n\u00e9tration par clou au niveau des cellules, essais thermiques et de court-circuit au niveau des cellules (conform\u00e9ment aux normes GB\/T 36276-2023 ou GB\/T 36276-2018), et les essais de surcharge 1C au niveau des modules (sur une configuration de module 1P52S) constituent des proc\u00e9dures d'essai distinctes. Les acheteurs doivent demander les rapports d'essai correspondants \u00e0 MegSolid afin de confirmer les r\u00e9f\u00e9rences exactes des mod\u00e8les, les quantit\u00e9s d'\u00e9chantillons et les limites des essais.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">R\u00e9ponse thermique conditionnelle : dans les conditions sp\u00e9cifi\u00e9es pour les essais de p\u00e9n\u00e9tration par un clou et de surcharge, les configurations de cellules hybrides solide-liquide MegSolid test\u00e9es ont pr\u00e9sent\u00e9 la r\u00e9ponse thermique indiqu\u00e9e. Les performances r\u00e9elles en mati\u00e8re de s\u00e9curit\u00e9 d\u00e9pendent de la conception des cellules, de l'architecture des modules, des conditions de fonctionnement et de la configuration compl\u00e8te de l'essai.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2d38842d auto-image elementor-widget elementor-widget-image\" data-id=\"2d38842d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"1536\" height=\"512\" src=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/megsolid-cell-abuse-test-results-nail-overcharge-v2-1536x512.webp\" class=\"attachment-1536x1536 size-1536x1536 wp-image-7930\" alt=\"Infographie pr\u00e9sentant les r\u00e9sultats des tests de r\u00e9sistance aux conditions extr\u00eames de MegSolid, illustrant la p\u00e9n\u00e9tration d&#039;un clou de 5 mm, la surcharge du module 1C, l&#039;\u00e9l\u00e9vation de temp\u00e9rature en cas de court-circuit et les valeurs de r\u00e9f\u00e9rence du d\u00e9clenchement thermique\" srcset=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/megsolid-cell-abuse-test-results-nail-overcharge-v2-1536x512.webp 1536w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/megsolid-cell-abuse-test-results-nail-overcharge-v2-300x100.webp 300w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/megsolid-cell-abuse-test-results-nail-overcharge-v2-1024x341.webp 1024w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/megsolid-cell-abuse-test-results-nail-overcharge-v2-768x256.webp 768w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/megsolid-cell-abuse-test-results-nail-overcharge-v2-18x6.webp 18w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/megsolid-cell-abuse-test-results-nail-overcharge-v2-600x200.webp 600w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/megsolid-cell-abuse-test-results-nail-overcharge-v2.webp 1920w\" sizes=\"(max-width: 1536px) 100vw, 1536px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c3c51cb4 auto-h3 elementor-widget elementor-widget-heading\" data-id=\"c3c51cb4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Alignement des packs MegSolid et des syst\u00e8mes C&amp;I sur les proc\u00e9dures d'autorisation des projets<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-eba45a5c auto-p elementor-widget elementor-widget-heading\" data-id=\"eba45a5c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Lors du choix de modules de batteries assembl\u00e9s, d'armoires C&amp;I ou de conteneurs de service public, les ing\u00e9nieurs EPC doivent v\u00e9rifier la configuration exacte et le champ d'application de la certification pour chaque mod\u00e8le :<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-cd8cc73b elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"cd8cc73b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Blocs-batteries 51,2 V pour rack et blocs-batteries mobiles :<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">\u2014 <strong><a href=\"https:\/\/www.solidess.com\/fr\/product\/batterie-de-stockage-denergie-solide-megsold\/\" target=\"_blank\" style=\"color:#61ce70\">MEG-Solid-512314FL1<\/a><\/strong> (batterie hybride LiFePO4 \u00e0 semi-conducteurs de 51,2 V, 314 Ah, 16,07 kWh, courant de charge maximal et de d\u00e9charge en continu de 200 A, imp\u00e9dance interne \u2264 15 m\u03a9, 8 000 cycles \u00e0 80 % de profondeur de d\u00e9charge (DoD)) : La page officielle du produit mentionne une protection IP21\/IP65 ainsi que les certifications UL, CE et UN 38.3. \u00c9tant donn\u00e9 que les indices IP21 et IP65 correspondent \u00e0 des configurations de bo\u00eetier diff\u00e9rentes (un m\u00eame bo\u00eetier ne peut pas pr\u00e9senter simultan\u00e9ment ces deux indices), les acheteurs doivent pr\u00e9ciser l'indice de protection requis et v\u00e9rifier le champ d'application exact de la norme UL pour chaque commande.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">\u2014 MG 512314 Pack amovible (314 Ah, 16 076 Wh, tension de fonctionnement de 40 V \u00e0 58,4 V, courant maximal de 200 A, \u2265 6 000 cycles) : La fiche technique du produit mentionne les normes UL 1741, CEI 62109-1, CEI 62109-2, EN 61000-6-1\/-6-3, FCC Partie 15 Classe B et RoHS. \u00c9tant donn\u00e9 que les normes UL 1741 et CEI 62109-1\/-2 concernent la conversion de puissance et la s\u00e9curit\u00e9 des onduleurs plut\u00f4t que les packs de batteries en tant que tels, les acheteurs doivent v\u00e9rifier aupr\u00e8s de MegSolid si ces normes s\u2019appliquent \u00e0 un onduleur associ\u00e9 ou \u00e0 la configuration compl\u00e8te du syst\u00e8me, et s\u2019assurer que les documents de certification du pack de batteries sont conformes aux exigences du site de leur projet.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Armoires commerciales, baies \u00e0 refroidissement par liquide et conteneurs utilitaires :<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">\u2014 <strong><a href=\"https:\/\/www.solidess.com\/fr\/product\/systeme-de-stockage-denergie-en-armoire-exterieure\/\" target=\"_blank\" style=\"color:#61ce70\">S\u00e9rie d'armoires d'ext\u00e9rieur ESSA<\/a><\/strong> (30 kW \u00e0 100 kW \/ 55,296 kWh \u00e0 215,04 kWh \u00e0 400 V CA, IP54) : Certaines caract\u00e9ristiques, telles que les transformateurs d'isolement int\u00e9gr\u00e9s, le syst\u00e8me d'extinction d'incendie \u00e0 base d'a\u00e9rosol ou de Novec 1230, ainsi que les configurations standard \u00e0 batteries LFP ou, en option, \u00e0 cellules \u00e0 semi-conducteurs sp\u00e9cifiques au projet, d\u00e9pendent du mod\u00e8le ESSA s\u00e9lectionn\u00e9 et des sp\u00e9cifications du contrat.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">\u2014 <strong><a href=\"https:\/\/www.solidess.com\/fr\/product\/stockage-denergie-solide-liquide-megasolide\/\" target=\"_blank\" style=\"color:#61ce70\">Syst\u00e8me Energon \u00e0 refroidissement liquide LFP C&amp;I<\/a><\/strong> (261,24 kWh, 125 kVA, configuration LFP 1P260S 314 Ah, tension de service de 676 V \u00e0 936 V CC, indice de protection IP54, rendement maximal du syst\u00e8me pouvant atteindre 90 % ; \u00e0 noter que le chiffre indiqu\u00e9 dans cette fiche technique correspond au rendement maximal du syst\u00e8me et non au rendement aller-retour), <strong><a href=\"https:\/\/www.solidess.com\/fr\/product\/systeme-de-stockage-denergie-conteneurise-megasolid-5000intl\/\" target=\"_blank\" style=\"color:#61ce70\">Conteneur \u00e0 refroidissement par liquide 5000INTL<\/a><\/strong> (5 015,9 kWh, 2 700 kW \u00e0 690 V CA, 1 123,2 V \u00e0 1 497,6 V CC, IP55), et <strong><a href=\"https:\/\/www.solidess.com\/fr\/product\/onduleur-de-stockage-denergie-megasolid\/\" target=\"_blank\" style=\"color:#61ce70\">PCS modulaires PMA080\/105\/125<\/a><\/strong> (de 80 kW \u00e0 125 kW, tension d'entr\u00e9e de 615 V \u00e0 950 V CC).<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c954f191 auto-p elementor-widget elementor-widget-heading\" data-id=\"c954f191\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\"><strong>Limite importante en mati\u00e8re de conformit\u00e9 :<\/strong> Des r\u00e9sultats favorables aux essais de mise \u00e0 l'\u00e9preuve des cellules ou des modules ne dispensent pas automatiquement une installation de syst\u00e8me de stockage d'\u00e9nergie par batterie (BESS) des exigences du code de pr\u00e9vention des incendies ni ne r\u00e9duisent automatiquement les distances de s\u00e9paration pr\u00e9vues par la norme NFPA 855. Toutes les mesures de protection contre l'incendie, les barri\u00e8res thermiques et les distances de recul d'installation d\u00e9pendent de l'\u00e9dition du code de pr\u00e9vention des incendies adopt\u00e9e, de l'homologation UL 9540 au niveau du syst\u00e8me, des rapports d'essai UL 9540A sp\u00e9cifiques au mod\u00e8le et de l'agr\u00e9ment officiel d\u00e9livr\u00e9 par l'autorit\u00e9 comp\u00e9tente locale (AHJ).<\/p>\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-46002f12 auto-faq e-flex e-con-boxed e-con e-child\" data-id=\"46002f12\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-7cf58b3b elementor-widget elementor-widget-heading\" data-id=\"7cf58b3b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">FAQ<\/h2>\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-bbe20c32 e-con-full e-flex e-con e-child\" data-id=\"bbe20c32\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-57f289a9 elementor-widget elementor-widget-n-accordion\" data-id=\"57f289a9\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;default_state&quot;:&quot;all_collapsed&quot;,&quot;max_items_expended&quot;:&quot;one&quot;,&quot;n_accordion_animation_duration&quot;:{&quot;unit&quot;:&quot;ms&quot;,&quot;size&quot;:400,&quot;sizes&quot;:[]}}\" data-widget_type=\"nested-accordion.default\">\n\t\t\t\t\t\t\t<div class=\"e-n-accordion\" aria-label=\"Accord\u00e9on. Ouvrez les liens \u00e0 l&#039;aide de la touche Entr\u00e9e ou de la barre d&#039;espace, fermez-les avec la touche \u00c9chap et naviguez \u00e0 l&#039;aide des touches fl\u00e9ch\u00e9es.\">\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-1470\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"1\" tabindex=\"0\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-1470\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> En quoi la norme UL 1973 diff\u00e8re-t-elle de la norme UL 2580 ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-1470\" class=\"elementor-element elementor-element-a4fe5b94 e-con-full e-flex e-con e-child\" data-id=\"a4fe5b94\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-1470\" class=\"elementor-element elementor-element-9953330a e-con-full e-flex e-con e-child\" data-id=\"9953330a\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-b5a205ff elementor-widget elementor-widget-heading\" data-id=\"b5a205ff\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Alors que la norme UL 1973 \u00e9value les batteries destin\u00e9es au stockage stationnaire, \u00e0 l'alimentation auxiliaire des v\u00e9hicules et aux applications ferroviaires \u00e9lectriques l\u00e9g\u00e8res, la norme UL 2580 (Norme relative aux batteries destin\u00e9es aux v\u00e9hicules \u00e9lectriques) \u00e9value sp\u00e9cifiquement les packs et modules de batteries de traction con\u00e7us pour la propulsion des v\u00e9hicules \u00e9lectriques dans des applications automobiles sur route et tout-terrain, en mettant l'accent sur les sc\u00e9narios extr\u00eames de collision automobile, d'immersion et de vibrations routi\u00e8res.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-1471\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"2\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-1471\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Pourquoi la norme UL 2054 ne remplace-t-elle g\u00e9n\u00e9ralement pas la norme UL 1973 dans les installations fixes de syst\u00e8mes de stockage d'\u00e9nergie par batterie (BESS) ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-1471\" class=\"elementor-element elementor-element-bffdf6af e-con-full e-flex e-con e-child\" data-id=\"bffdf6af\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-1471\" class=\"elementor-element elementor-element-53b0cf9e e-con-full e-flex e-con e-child\" data-id=\"53b0cf9e\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-de35887e elementor-widget elementor-widget-heading\" data-id=\"de35887e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">La norme UL 2054 s'applique aux batteries portables \u00e0 usage domestique et commercial utilis\u00e9es dans les outils portatifs, les appareils \u00e9lectroniques mobiles et les \u00e9quipements portables. Si la norme UL 2054 est adapt\u00e9e dans le cadre de son champ d'application portant sur les \u00e9quipements portables, les installations fixes de stockage d'\u00e9nergie r\u00e9gies par l'article 706 du NEC, de la norme NFPA 855 et du Code international de pr\u00e9vention des incendies (International Fire Code) exigent g\u00e9n\u00e9ralement que les modules de batterie soient \u00e9valu\u00e9s selon la norme UL 1973 (y compris les exigences relatives \u00e0 la r\u00e9sistance di\u00e9lectrique en installation fixe et au confinement des d\u00e9faillances internes des cellules) dans le cadre d\u2019une d\u00e9marche de conformit\u00e9 au niveau du syst\u00e8me, sous r\u00e9serve des codes locaux et des exigences de l\u2019autorit\u00e9 comp\u00e9tente (AHJ).<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-1472\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"3\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-1472\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Dans quelles conditions les normes UL 991 et UL 1998 s'appliquent-elles \u00e0 un syst\u00e8me de gestion des b\u00e2timents (BMS) ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-1472\" class=\"elementor-element elementor-element-453cd0e6 e-con-full e-flex e-con e-child\" data-id=\"453cd0e6\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-1472\" class=\"elementor-element elementor-element-3432ffd5 e-con-full e-flex e-con e-child\" data-id=\"3432ffd5\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-615d3afc elementor-widget elementor-widget-heading\" data-id=\"615d3afc\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Les normes UL 991 et UL 1998 ne constituent pas des certificats autonomes obligatoires pour chaque syst\u00e8me de gestion de batterie (BMS). Elles s'appliquent en tant que normes d'\u00e9valuation de la s\u00e9curit\u00e9 fonctionnelle lorsqu'un bloc-batterie ou un syst\u00e8me de stockage d'\u00e9nergie s'appuie sur des commandes \u00e9lectroniques \u00e0 semi-conducteurs (UL 991) ou sur des logiciels\/micrologiciels programmables (UL 1998) pour ex\u00e9cuter des coupures de protection primaires critiques pour la s\u00e9curit\u00e9, et lorsque ces commandes ne sont pas prot\u00e9g\u00e9es exclusivement par des dispositifs \u00e9lectrom\u00e9caniques passifs ou ne sont pas d\u00e9j\u00e0 qualifi\u00e9es selon une autre norme de s\u00e9curit\u00e9 fonctionnelle reconnue (telle que UL 60730-1, CEI 61508 ou ISO 13849) accept\u00e9e dans le cadre de l\u2019\u00e9valuation parentale selon UL 1973 ou UL 9540.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-1473\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"4\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-1473\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Quelle est la diff\u00e9rence entre la certification UL 9540 et les essais UL 9540A ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-1473\" class=\"elementor-element elementor-element-a33b542e e-con-full e-flex e-con e-child\" data-id=\"a33b542e\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-1473\" class=\"elementor-element elementor-element-e3a95692 e-con-full e-flex e-con e-child\" data-id=\"e3a95692\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ef21fa48 elementor-widget elementor-widget-heading\" data-id=\"ef21fa48\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">La norme UL 9540 est une norme de s\u00e9curit\u00e9 des produits qui \u00e9value un syst\u00e8me complet de stockage d'\u00e9nergie et d\u00e9livre un marquage de certification en cas de conformit\u00e9. La norme UL 9540A est une m\u00e9thode d'essai au feu (et non une certification) qui mesure la propagation d'un incendie par emballement thermique, les d\u00e9bits de d\u00e9gagement de chaleur et la composition des gaz \u00e9mis, afin de fournir des donn\u00e9es d'essais techniques pour l'examen de la conformit\u00e9 aux codes de pr\u00e9vention des incendies selon la norme NFPA 855 et l'IFC.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-1474\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"5\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-1474\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Quels sont les niveaux d'essai pr\u00e9vus par la norme UL 9540A, et en quoi les 5e et 6e \u00e9ditions diff\u00e8rent-elles ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-1474\" class=\"elementor-element elementor-element-d6ee3b1c e-con-full e-flex e-con e-child\" data-id=\"d6ee3b1c\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-1474\" class=\"elementor-element elementor-element-0a20d7e6 e-con-full e-flex e-con e-child\" data-id=\"0a20d7e6\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-370c54bb elementor-widget elementor-widget-heading\" data-id=\"370c54bb\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Dans la 5e \u00e9dition de la norme UL 9540A, les essais \u00e9taient organis\u00e9s en quatre niveaux : niveau cellule, niveau module, niveau unit\u00e9 et niveau installation. Dans la 6e \u00e9dition de la norme UL 9540A, la norme conserve les essais au feu \u00e0 grande \u00e9chelle au niveau de la cellule, au niveau du module et au niveau de l'installation, tout en r\u00e9visant l'applicabilit\u00e9 et le champ d'application des essais au niveau de l'unit\u00e9. Dans les deux \u00e9ditions, tous les rapports d\u2019essai ne n\u00e9cessitent pas la r\u00e9alisation de tous les niveaux ; la d\u00e9cision de passer \u00e0 des niveaux sup\u00e9rieurs d\u00e9pend des r\u00e9sultats thermiques et de propagation observ\u00e9s aux \u00e9tapes pr\u00e9c\u00e9dentes, ainsi que de la configuration d\u2019installation pr\u00e9vue.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-1475\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"6\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-1475\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Comment l'autorit\u00e9 comp\u00e9tente examine-t-elle les rapports d'essais BESS lors de la proc\u00e9dure d'autorisation d'un projet ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-1475\" class=\"elementor-element elementor-element-b39d47e8 e-con-full e-flex e-con e-child\" data-id=\"b39d47e8\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-1475\" class=\"elementor-element elementor-element-fd1635d7 e-con-full e-flex e-con e-child\" data-id=\"fd1635d7\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-438bcd0d elementor-widget elementor-widget-heading\" data-id=\"438bcd0d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Lors de l'examen des plans, l'autorit\u00e9 comp\u00e9tente locale (responsable du b\u00e2timent et chef des pompiers) v\u00e9rifie g\u00e9n\u00e9ralement que l'\u00e9quipement dispose d'une homologation de syst\u00e8me applicable (telle que la norme UL 9540) d\u00e9livr\u00e9e par un NRTL accr\u00e9dit\u00e9 pour la configuration exacte de la batterie et du PCS, examine le rapport d\u2019essai au feu UL 9540A sp\u00e9cifique au mod\u00e8le afin d\u2019\u00e9valuer la propagation de l\u2019emballement thermique et la production de gaz inflammables, et v\u00e9rifie que la capacit\u00e9 du syst\u00e8me, les distances de s\u00e9paration, la ventilation, le contr\u00f4le de la d\u00e9flagration et la lutte contre l\u2019incendie sont conformes aux \u00e9ditions adopt\u00e9es localement de la norme NFPA 855, de l\u2019IFC, de l\u2019IBC et du NEC.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-1476\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"7\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-1476\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Les marques ETL, CSA ou T\u00dcV b\u00e9n\u00e9ficient-elles de la m\u00eame reconnaissance que la marque UL ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-1476\" class=\"elementor-element elementor-element-45fba218 e-con-full e-flex e-con e-child\" data-id=\"45fba218\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-1476\" class=\"elementor-element elementor-element-dc09c1c4 e-con-full e-flex e-con e-child\" data-id=\"dc09c1c4\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-4c525e3e elementor-widget elementor-widget-heading\" data-id=\"4c525e3e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Les certifications ETL, CSA ou autres certifications NRTL peuvent constituer une alternative valable \u00e0 une certification d\u00e9livr\u00e9e par UL lorsque l'organisme \u00e9metteur est accr\u00e9dit\u00e9 par l'OSHA (ou par le Conseil canadien des normes au Canada) pour la cat\u00e9gorie de produit et la norme d'essai sp\u00e9cifiques (telles que UL 1973 ou UL 9540), et que l'homologation couvre exactement la configuration de l'\u00e9quipement. \u00c9tant donn\u00e9 que la reconnaissance NRTL de l'OSHA se limite au champ d'application publi\u00e9 par chaque laboratoire, et que les autorit\u00e9s locales comp\u00e9tentes (AHJ) et les assureurs immobiliers conservent un pouvoir d'examen ind\u00e9pendant, les acheteurs doivent v\u00e9rifier le champ d'application du laboratoire ainsi que l'acceptation par les autorit\u00e9s locales comp\u00e9tentes et les assureurs avant de proc\u00e9der \u00e0 l'achat.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-1477\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"8\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-1477\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Quelles sont les options de mise en conformit\u00e9 si un projet comprend un rack de batteries conforme \u00e0 la norme UL 1973, mais ne dispose pas d'une homologation conjointe UL 9540 avec l'onduleur s\u00e9lectionn\u00e9 ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-1477\" class=\"elementor-element elementor-element-23546610 e-con-full e-flex e-con e-child\" data-id=\"23546610\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-1477\" class=\"elementor-element elementor-element-3b4e4bc3 e-con-full e-flex e-con e-child\" data-id=\"3b4e4bc3\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-6d6f0c8c elementor-widget elementor-widget-heading\" data-id=\"6d6f0c8c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Lorsqu'un ensemble de batteries et un syst\u00e8me de conversion de puissance ne sont pas couverts conjointement par un agr\u00e9ment UL 9540 existant, les \u00e9quipes de projet \u00e9valuent g\u00e9n\u00e9ralement plusieurs options en fonction des exigences r\u00e9glementaires locales et des politiques de l'autorit\u00e9 comp\u00e9tente (AHJ) : choisir un mod\u00e8le d\u2019onduleur\/PCS d\u00e9j\u00e0 inclus dans la matrice d\u2019homologation UL 9540 multi-PCS du fabricant de batteries ; collaborer avec le fabricant pour \u00e9tendre l\u2019homologation UL 9540 d\u2019usine afin d\u2019y inclure le PCS vis\u00e9 ; ou (lorsque l\u2019autorit\u00e9 comp\u00e9tente locale et les codes applicables le permettent) faire appel \u00e0 un NRTL accr\u00e9dit\u00e9 pour r\u00e9aliser une \u00e9valuation sur site sp\u00e9cifique, \u00e9tay\u00e9e par les homologations des composants et les donn\u00e9es d\u2019essai UL 9540A.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-1478\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"9\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-1478\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Quel est le lien entre la norme CEI 62619 et les normes UL 1973 et UL 9540 ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-1478\" class=\"elementor-element elementor-element-7e46a60e e-con-full e-flex e-con e-child\" data-id=\"7e46a60e\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-1478\" class=\"elementor-element elementor-element-387f9ccb e-con-full e-flex e-con e-child\" data-id=\"387f9ccb\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-9512dc20 elementor-widget elementor-widget-heading\" data-id=\"9512dc20\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">La norme CEI 62619 est une norme internationale de s\u00e9curit\u00e9 relative aux piles et batteries au lithium secondaires utilis\u00e9es dans des applications industrielles (notamment le stockage stationnaire, les t\u00e9l\u00e9communications et les \u00e9quipements de propulsion). Bien que la norme CEI 62619 partage certains concepts d\u2019essais de mise en situation d\u2019abus avec la norme UL 1973 et qu\u2019elle soit largement exig\u00e9e sur les march\u00e9s europ\u00e9ens, asiatiques et internationaux, un rapport d\u2019essai conforme \u00e0 la norme CEI 62619 ne saurait \u00e0 lui seul se substituer \u00e0 une homologation UL 1973 ou UL 9540 dans les juridictions nord-am\u00e9ricaines appliquant le NEC, CEC ou NFPA 855.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-1479\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"10\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-1479\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> En quoi les exigences en mati\u00e8re de certification et d'approvisionnement des syst\u00e8mes de stockage d'\u00e9nergie par batterie (BESS) diff\u00e8rent-elles entre les \u00c9tats-Unis, le Canada et l'Am\u00e9rique du Nord ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-1479\" class=\"elementor-element elementor-element-7e945d3f e-con-full e-flex e-con e-child\" data-id=\"7e945d3f\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-1479\" class=\"elementor-element elementor-element-fe54ea73 e-con-full e-flex e-con e-child\" data-id=\"fe54ea73\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-d655abf3 elementor-widget elementor-widget-heading\" data-id=\"d655abf3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Aux \u00c9tats-Unis, les installations sont r\u00e9gies par le Code national de l'\u00e9lectricit\u00e9 (NEC, article 706), le Code international de pr\u00e9vention des incendies (IFC) et la norme NFPA 855, sur la base de certifications d\u00e9livr\u00e9es par des laboratoires NRTL agr\u00e9\u00e9s par l'OSHA (test\u00e9s selon des normes telles que UL 1973 et UL 9540). Au Canada, les installations doivent \u00eatre conformes au Code canadien de l'\u00e9lectricit\u00e9 (CEC, partie I) et aux codes provinciaux de pr\u00e9vention des incendies, ce qui n\u00e9cessite des marques de certification accept\u00e9es par les autorit\u00e9s provinciales d'inspection \u00e9lectrique et d\u00e9livr\u00e9es par des organismes de certification accr\u00e9dit\u00e9s par le Conseil canadien des normes (SCC), tels que CSA, cUL ou cETL, \u00e9valu\u00e9es selon des normes binationales harmonis\u00e9es (notamment ANSI\/CAN\/UL 1973 et ANSI\/CAN\/UL 9540) et les normes nationales canadiennes applicables. Pour les achats transfrontaliers en Am\u00e9rique du Nord, les acheteurs doivent sp\u00e9cifier des marques de certification doubles \u00c9tats-Unis\/Canada (cULus, cETLus ou CSA c\/us) couvrant le mod\u00e8le exact du syst\u00e8me.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4e662795 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"4e662795\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Acc\u00e9l\u00e9rez votre projet de stockage d'\u00e9nergie gr\u00e2ce \u00e0 un accompagnement technique certifi\u00e9<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-33140501 auto-p elementor-widget elementor-widget-heading\" data-id=\"33140501\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Pour obtenir les autorisations n\u00e9cessaires et souscrire une assurance commerciale pour les installations de batteries en Am\u00e9rique du Nord, il est indispensable d\u2019harmoniser la documentation relative aux cellules, aux modules, aux syst\u00e8mes de contr\u00f4le et \u00e0 l\u2019ensemble du syst\u00e8me avant que les \u00e9quipements ne quittent l\u2019usine. Le choix de plateformes de stockage dont les donn\u00e9es d\u2019essais de r\u00e9sistance aux conditions extr\u00eames ont \u00e9t\u00e9 v\u00e9rifi\u00e9es et dont le p\u00e9rim\u00e8tre de certification est transparent permet d\u2019\u00e9viter que les d\u00e9lais d\u2019obtention des autorisations ne compromettent le calendrier des projets.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d8bb7692 auto-p elementor-widget elementor-widget-heading\" data-id=\"d8bb7692\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Lors de votre demande de devis (RFQ) et de votre analyse technique, contactez MegSolid\u2019s <strong><a href=\"https:\/\/www.solidess.com\/fr\/bess-oem-odm\/\" target=\"_blank\" style=\"color:#61ce70\">\u00e9quipe d'ing\u00e9nieurs<\/a><\/strong> pour v\u00e9rifier les rapports d'essais NRTL sp\u00e9cifiques \u00e0 chaque mod\u00e8le, les champs d'application des normes applicables et les matrices de compatibilit\u00e9 PCS pour la juridiction de votre choix :<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7724401d elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"7724401d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">D\u00e9couvrez nos architectures cl\u00e9s en main hautement s\u00e9curis\u00e9es : d\u00e9couvrez nos syst\u00e8mes de stockage d'\u00e9nergie \u00e0 semi-conducteurs sous forme de cellules, de racks et de conteneurs.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Configurer les armoires et racks modulaires C&amp;I : comparez les plages de tension, les topologies de refroidissement et les caract\u00e9ristiques techniques des armoires de notre gamme de solutions de stockage d'\u00e9nergie pour les secteurs commercial et industriel (C&amp;I).<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2774b97a elementor-tablet-align-center elementor-align-center auto-cta elementor-widget elementor-widget-button\" data-id=\"2774b97a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"#elementor-action%3Aaction%3Dpopup%3Aopen%26settings%3DeyJpZCI6Ijk0OCIsInRvZ2dsZSI6ZmFsc2V9\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Contactez-nous pour un examen de la documentation relative \u00e0 la conformit\u00e9 BESS<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Comparez les exigences des normes UL 1642, UL 2054, UL 1973, UL 991, UL 1998 et UL 9540 relatives aux cellules de batterie au lithium, aux packs, aux syst\u00e8mes de gestion de batterie (BMS) et aux installations compl\u00e8tes de syst\u00e8mes de stockage d'\u00e9nergie par batterie (BESS). D\u00e9couvrez comment v\u00e9rifier les rapports d'essai sp\u00e9cifiques \u00e0 chaque mod\u00e8le et le champ d'application de la certification NRTL avant tout achat.<\/p>","protected":false},"author":4,"featured_media":7927,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"_joinchat":[],"footnotes":""},"categories":[1,713],"tags":[923,924,922,915,917,919,916,920,921,918,914],"class_list":["post-7931","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-bess","category-bess-procurement-economics","tag-bess-safety-certification","tag-megsolid-hybrid-solid-liquid-cells","tag-nrtl-compliance","tag-ul-1642","tag-ul-1973-certification","tag-ul-1998","tag-ul-2054","tag-ul-9540-certification","tag-ul-9540a-testing","tag-ul-991","tag-ul-certified-lithium-batteries"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/posts\/7931","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/comments?post=7931"}],"version-history":[{"count":4,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/posts\/7931\/revisions"}],"predecessor-version":[{"id":7935,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/posts\/7931\/revisions\/7935"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/media\/7927"}],"wp:attachment":[{"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/media?parent=7931"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/categories?post=7931"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/tags?post=7931"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}