{"id":7950,"date":"2026-11-04T12:26:37","date_gmt":"2026-11-04T04:26:37","guid":{"rendered":"https:\/\/www.solidess.com\/?p=7950"},"modified":"2026-11-04T12:26:37","modified_gmt":"2026-11-04T04:26:37","slug":"capacite-nominale-vs-capacite-nominale-guide-de-bess","status":"publish","type":"post","link":"https:\/\/www.solidess.com\/fr\/nominal-vs-rated-capacity-bess-guide\/","title":{"rendered":"Nominal Capacity vs. Rated Capacity in Lithium BESS: How to Calculate True Usable kWh in 314Ah C&amp;I &amp; Home Storage"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"7950\" class=\"elementor elementor-7950\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-bf4793c e-con-full auto-article-root e-flex e-con e-parent\" data-id=\"bf4793c\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-6e5e7282 auto-p elementor-widget elementor-widget-heading\" data-id=\"6e5e7282\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Lors de l'\u00e9valuation de la fiche technique d'un syst\u00e8me de stockage solaire ou d'une batterie commerciale, confondre la capacit\u00e9 nominale avec la capacit\u00e9 nominale, ou ne pas faire la distinction entre la capacit\u00e9 de charge (Ah), l'\u00e9nergie nominale (kWh), l'\u00e9nergie de d\u00e9charge mesur\u00e9e et l'\u00e9nergie CA nette utilisable, peut emp\u00eacher un projet d'atteindre la dur\u00e9e requise pour l'\u00e9cr\u00eatement des pics ou l'alimentation de secours. Conform\u00e9ment aux normes internationales relatives aux batteries, telles que les normes CEI 62620, CEI 62619 et UL 1973, la capacit\u00e9 nominale et la capacit\u00e9 nominale (souvent recherch\u00e9e sous le terme \u00ab capacit\u00e9 de nominal \u00bb) font principalement r\u00e9f\u00e9rence \u00e0 la charge \u00e9lectrique en amp\u00e8res-heures (Ah), alors que le dimensionnement d\u2019un syst\u00e8me de stockage d\u2019\u00e9nergie n\u00e9cessite de convertir ces chiffres en kilowattheures (kWh) en fonction de plages de tension, de taux de d\u00e9charge et de rendements de conversion d\u00e9finis.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-12495ca9 auto-p elementor-widget elementor-widget-heading\" data-id=\"12495ca9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Que vous choisissiez une armoire ESSA de 215,04 kWh (280 Ah LFP), une armoire Energon \u00e0 refroidissement liquide de 261,24 kWh (314 Ah LFP) ou un conteneur de 5 015,9 kWh issu de notre gamme <strong><a href=\"https:\/\/www.solidess.com\/fr\/piles\/stockage-denergie-ci\/\" target=\"_blank\" style=\"color:#61ce70\">Stockage d'\u00e9nergie \u00e0 usage commercial et industriel (C&amp;I)<\/a><\/strong> gamme, ou en choisissant une unit\u00e9 de stockage de 51,2 V et 314 Ah parmi notre <strong><a href=\"https:\/\/www.solidess.com\/fr\/piles\/stockage-denergie-residentiel\/\" target=\"_blank\" style=\"color:#61ce70\">Syst\u00e8mes de stockage d'\u00e9nergie \u00e0 usage r\u00e9sidentiel<\/a><\/strong> Dans ce contexte, le pr\u00e9sent guide technique explique les d\u00e9finitions pr\u00e9cises, les \u00e9quations et les limites de fonctionnement du syst\u00e8me de gestion de batterie (BMS) qui r\u00e9gissent les kilowattheures livrables.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8b1b5e0e auto-image elementor-widget elementor-widget-image\" data-id=\"8b1b5e0e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"1536\" height=\"1024\" src=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/nominal-vs-rated-capacity-key-points-overview-1536x1024.webp\" class=\"attachment-1536x1536 size-1536x1536 wp-image-7947\" alt=\"Infographie r\u00e9sumant la charge nominale de la batterie en Ah, la capacit\u00e9 nominale indiqu\u00e9e par le fabricant, l&#039;\u00e9nergie utilisable en kWh CA, les effets de la temp\u00e9rature et du taux de d\u00e9charge, ainsi que les seuils de l&#039;\u00e9tat de sant\u00e9 (SOH)\" srcset=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/nominal-vs-rated-capacity-key-points-overview-1536x1024.webp 1536w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/nominal-vs-rated-capacity-key-points-overview-300x200.webp 300w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/nominal-vs-rated-capacity-key-points-overview-1024x683.webp 1024w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/nominal-vs-rated-capacity-key-points-overview-768x512.webp 768w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/nominal-vs-rated-capacity-key-points-overview-18x12.webp 18w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/nominal-vs-rated-capacity-key-points-overview-600x400.webp 600w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/nominal-vs-rated-capacity-key-points-overview.webp 1920w\" sizes=\"(max-width: 1536px) 100vw, 1536px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a23d5105 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"a23d5105\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Qu'est-ce que la capacit\u00e9 d'une batterie ? Distinguer la capacit\u00e9 en Ah, l'\u00e9nergie nominale et les kWh utilisables<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-986830d5 auto-p elementor-widget elementor-widget-heading\" data-id=\"986830d5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Avant de comparer les offres de stockage commercial, les ing\u00e9nieurs charg\u00e9s des achats et les installateurs solaires doivent obtenir une r\u00e9ponse pr\u00e9cise \u00e0 deux questions fondamentales : qu'est-ce que la capacit\u00e9 d'une batterie, et pourquoi les fiches techniques des cellules et des syst\u00e8mes indiquent-elles des valeurs diff\u00e9rentes pour les amp\u00e8res-heures (Ah) et les kilowattheures (kWh) ?<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-58733e05 auto-p elementor-widget elementor-widget-heading\" data-id=\"58733e05\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Lorsqu'on demande ce qu'est la capacit\u00e9 d'une batterie en g\u00e9nie \u00e9lectrochimique, la r\u00e9ponse n\u00e9cessite de distinguer la charge coulombique de l'\u00e9nergie \u00e9lectrique et de pr\u00e9ciser l'unit\u00e9 de temps exacte (t en heures ou en secondes) :<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-12f5071b elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"12f5071b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Capacit\u00e9 de charge \u00e9lectrique (Ah, amp\u00e8res-heures) : quantit\u00e9 de charge \u00e9lectrique fournie lorsqu'une cellule ou une batterie se d\u00e9charge entre des tensions de coupure sp\u00e9cifi\u00e9es, dans des conditions d'essai d\u00e9finies. Si le temps t est mesur\u00e9 en heures (h), la capacit\u00e9 est \u00e9gale \u00e0 \u222b I(t) dt ; si un BMS ou un cyclateur de laboratoire \u00e9chantillonne le temps en secondes (s), l'int\u00e9grale est divis\u00e9e par 3 600 :<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9a46f458 auto-p elementor-widget elementor-widget-heading\" data-id=\"9a46f458\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">C_Ah = \u222b(de t\u2080 \u00e0 t_cut) I(t) dt (heures) = (1 \/ 3600) \u00d7 \u222b(de t\u2080 \u00e0 t_cut) I(t) dt (secondes)<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6dbeadf1 elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"6dbeadf1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">\u00c9nergie de d\u00e9charge \u00e9lectrique (Wh ou kWh) : int\u00e9grale dans le temps de la tension aux bornes multipli\u00e9e par le courant de d\u00e9charge, qui d\u00e9termine la dur\u00e9e pendant laquelle un syst\u00e8me de stockage peut alimenter une charge alternative exprim\u00e9e en kilowatts (kW) :<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b631bd8f auto-p elementor-widget elementor-widget-heading\" data-id=\"b631bd8f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">E_Wh = \u222b(de t\u2080 \u00e0 t_cut) V(t) \u00d7 I(t) dt (heures) = (1 \/ 3 600) \u00d7 \u222b(de t\u2080 \u00e0 t_cut) V(t) \u00d7 I(t) dt (secondes)<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-28aa54a0 auto-p elementor-widget elementor-widget-heading\" data-id=\"28aa54a0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Afin de lever toute ambigu\u00eft\u00e9 entre la terminologie relative aux cellules de la norme CEI 62620 et l'ing\u00e9nierie des syst\u00e8mes de stockage d'\u00e9nergie par batterie (BESS) au niveau du syst\u00e8me, le tableau 1 d\u00e9finit les six param\u00e8tres distincts qui doivent \u00eatre diff\u00e9renci\u00e9s lors de l'audit technique.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-175ea287 auto-h3 elementor-widget elementor-widget-heading\" data-id=\"175ea287\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Tableau 1 : Six d\u00e9finitions relatives \u00e0 la tension nominale, \u00e0 la capacit\u00e9 (Ah) et \u00e0 l'\u00e9nergie (kWh) dans les syst\u00e8mes de stockage d'\u00e9nergie par batterie (BESS)<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-38bda041 auto-table elementor-widget elementor-widget-text-editor\" data-id=\"38bda041\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"cea-table-wrap\"><table><thead><tr><th>Param\u00e8tre<\/th><th>D\u00e9finition technique standard (CEI 62620 \/ Pratique BESS)<\/th><th>Unit\u00e9 et formule de calcul<\/th><th>Exemple au niveau de la cellule (feuille de cellules SHS180-314Ah)<\/th><th>Exemple au niveau du syst\u00e8me (Energon \/ unit\u00e9s de 51,2 V)<\/th><\/tr><\/thead><tbody><tr><td>1. Tension nominale (V_nom)<\/td><td>Tension de r\u00e9f\u00e9rence approximative utilis\u00e9e pour d\u00e9signer ou identifier une cellule ou un syst\u00e8me de batteries.<\/td><td>Volts (V)<\/td><td>3,2 V nominaux par cellule<\/td><td>51,2 V (16S suppos\u00e9) ; 832 V (Energon 1P260S)<\/td><\/tr><tr><td>2. Capacit\u00e9 nominale (C_nom)<\/td><td>Quantit\u00e9 de charge de r\u00e9f\u00e9rence utilis\u00e9e par un fabricant pour d\u00e9terminer la taille d'une cellule ou d'une batterie.<\/td><td>Amp\u00e8res-heures (Ah)<\/td><td>R\u00e9f\u00e9rence de la classe 314 Ah<\/td><td>314 Ah (Energon, MG 512314, MEG-Solid-512314FL1) ; 280 Ah (ESSA0100B-0215)<\/td><\/tr><tr><td>3. Capacit\u00e9 nominale (C_rated \/ Capacit\u00e9 nominale)<\/td><td>Conform\u00e9ment \u00e0 la norme CEI 62620, valeur de capacit\u00e9 (Ah) d\u00e9termin\u00e9e dans des conditions sp\u00e9cifi\u00e9es et d\u00e9clar\u00e9e par le fabricant.<\/td><td>Ah v\u00e9rifi\u00e9 \u00e0 la charge, \u00e0 la temp\u00e9rature et \u00e0 la tension de coupure sp\u00e9cifi\u00e9es<\/td><td>Capacit\u00e9 nominale de 314 Ah (caract\u00e9ristiques techniques de la cellule SHS180-314Ah en version autonome)<\/td><td>Capacit\u00e9 nominale de 314 Ah pour les mod\u00e8les MEG-Solid-512314FL1 et MG 512314<\/td><\/tr><tr><td>4. \u00c9nergie nominale (E_nom)<\/td><td>\u00c9nergie \u00e9lectrique de r\u00e9f\u00e9rence estim\u00e9e ou d\u00e9termin\u00e9e \u00e0 partir de la tension nominale et de la puissance nominale.<\/td><td>Wh ou kWh ; E_nom = N_s \u00d7 V_nom \u00d7 C<\/td><td>3,2 V \u00d7 314 Ah = 1 004,8 Wh (produit th\u00e9orique)<\/td><td>260 \u00d7 3,2 V \u00d7 314 Ah = 261,248 kWh (Energon indique 261,24 kWh) ; 16 \u00d7 3,2 V \u00d7 314 Ah = 16 076,8 Wh (le mod\u00e8le MG 512314 indique 16 076 Wh)<\/td><\/tr><tr><td>5. \u00c9nergie mesur\u00e9e \/ nominale (E_dis)<\/td><td>\u00c9nergie \u00e9lectrique fournie ou d\u00e9clar\u00e9e dans des conditions d'essai de d\u00e9charge sp\u00e9cifi\u00e9es.<\/td><td>Wh ou kWh ; \u222b V(t)I(t) dt<\/td><td>\u00c9nergie nominale de 1 005 Wh selon les sp\u00e9cifications de la cellule SHS180-314Ah (\u00e0 0,5P, 25 \u00b0C)<\/td><td>\u00c9nergie au niveau du syst\u00e8me v\u00e9rifi\u00e9e selon le protocole FAT du mod\u00e8le et la plage de tension de fonctionnement<\/td><\/tr><tr><td>6. \u00c9nergie CA utilisable (E_usable_AC)<\/td><td>\u00c9nergie nette fournie au point de couplage CA apr\u00e8s prise en compte de la fen\u00eatre SOC, des pertes du PCS et des \u00e9quipements auxiliaires.<\/td><td>kWh ; E_install\u00e9e \u00d7 DoD \u00d7 \u03b7_del<\/td><td>N\/A (la cellule fonctionne uniquement en courant continu)<\/td><td>\u00c0 titre indicatif : 188,09 kWh sur Energon (\u00e0 80 % de profondeur de d\u00e9charge et avec un rendement de livraison suppos\u00e9 de 90 %)<\/td><\/tr><\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-eaff4116 auto-p elementor-widget elementor-widget-heading\" data-id=\"eaff4116\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Remarques techniques concernant le tableau 1 :<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3b73da87 elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"3b73da87\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Distinction entre les caract\u00e9ristiques au niveau de la cellule et les caract\u00e9ristiques au niveau du syst\u00e8me : La fiche technique de la cellule hybride solide-liquide SHS180-314Ah, consid\u00e9r\u00e9e isol\u00e9ment, indique \u00e0 la fois une capacit\u00e9 nominale de 314 Ah et une \u00e9nergie nominale de 1 005 Wh (contre la valeur th\u00e9orique nominale du produit : 3,2 V \u00d7 314 Ah = 1 004,8 Wh). Cette sp\u00e9cification au niveau de la cellule est distincte des fiches techniques au niveau du syst\u00e8me (telles que celles du coffret standard LFP Energon de 261,24 kWh ou de l'unit\u00e9 MEG-Solid-512314FL1 de 16,07 kWh) et ne peut pas \u00eatre automatiquement transpos\u00e9e d'une gamme de produits \u00e0 l'autre sans v\u00e9rifier le mod\u00e8le exact de cellule install\u00e9 dans chaque syst\u00e8me.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Comparaison illustrative entre l'\u00e9nergie CA utilisable et le rendement officiel du syst\u00e8me : \u00e0 la ligne 6 du tableau 1, 261,24 kWh \u00d7 0,80 \u00d7 0,90 = 188,09 kWh (ou 211,60 kWh \u00e0 90 % de profondeur de d\u00e9charge (DoD)) est un calcul illustratif montrant comment la profondeur de d\u00e9charge (DoD) et les pertes de conversion r\u00e9duisent la puissance CA disponible. Le chiffre de 90 % utilis\u00e9 dans cette formule est une donn\u00e9e hypoth\u00e9tique ; les ing\u00e9nieurs ne doivent pas remplacer directement le rendement maximal de 90 % indiqu\u00e9 dans la fiche technique d'Energon par le rendement de sortie CA mesur\u00e9 sur site sans tenir compte du facteur de charge, des pertes du transformateur et de la consommation d'\u00e9nergie li\u00e9e au refroidissement liquide auxiliaire.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Classification des cellules en usine et v\u00e9rification des lots : Au cours de la fabrication, les cellules font l\u2019objet d\u2019un classement de formation afin de regrouper les unit\u00e9s en fonction de leur capacit\u00e9, de leur tension en circuit ouvert (OCV) et de leur r\u00e9sistance interne. \u00c9tant donn\u00e9 que les tol\u00e9rances de tri sp\u00e9cifiques et les seuils minimaux d\u2019acceptation d\u00e9pendent des normes de qualit\u00e9 en usine pour chaque lot de production, les acheteurs d\u2019EPC doivent demander les crit\u00e8res d\u2019inspection des lots et les rapports des essais de r\u00e9ception en usine (FAT) lors de l\u2019approvisionnement.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ebd53838 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"ebd53838\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">D\u00e9finition de la capacit\u00e9 nominale et calcul de la capacit\u00e9 nominale d'un syst\u00e8me de stockage d'\u00e9nergie par batterie (BESS) de 314 Ah<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6db21f69 auto-p elementor-widget elementor-widget-heading\" data-id=\"6db21f69\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Pour interpr\u00e9ter correctement les rapports d'essais de laboratoire \u00e9tablis selon les normes CEI 62620, CEI 62619, UL 1973 ou GB\/T 36276-2023, les acheteurs doivent comprendre comment les protocoles relatifs au taux de d\u00e9charge et les seuils de coupure de tension permettent de distinguer les valeurs de r\u00e9f\u00e9rence nominales des r\u00e9sultats mesur\u00e9s lors des essais.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-81cdaf5c auto-h3 elementor-widget elementor-widget-heading\" data-id=\"81cdaf5c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">D\u00e9finition formelle de la capacit\u00e9 nominale vs \u00e9nergie nominale<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b44cfa6f auto-p elementor-widget elementor-widget-heading\" data-id=\"b44cfa6f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Dans les normes relatives aux batteries, la d\u00e9finition formelle de la capacit\u00e9 nominale correspond \u00e0 la valeur de r\u00e9f\u00e9rence de la charge \u00e9lectrique (exprim\u00e9e en amp\u00e8res-heures, Ah) d\u00e9sign\u00e9e par le fabricant pour identifier une cellule ou un syst\u00e8me de batteries. Lorsque les fabricants multiplient cette capacit\u00e9 nominale ou nominale en Ah par la tension de r\u00e9f\u00e9rence nominale de la cellule (3,2 V pour le LiFePO\u2084 et le LFP hybride solide-liquide) et par le nombre de cellules en s\u00e9rie (N_s), le produit obtenu (N_s \u00d7 3,2 V \u00d7 Ah) est correctement appel\u00e9 \" \u00e9nergie nominale \" (Wh ou kWh), bien que les brochures commerciales d\u00e9signent souvent de mani\u00e8re impr\u00e9cise tant les Ah que les kWh sous le terme g\u00e9n\u00e9rique de \u00ab capacit\u00e9 \u00bb.\"<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-59f42689 auto-p elementor-widget elementor-widget-heading\" data-id=\"59f42689\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Au cours d'un cycle de d\u00e9charge r\u00e9el \u00e0 25 \u00b0C, la tension aux bornes d'une cellule n'est pas fixe \u00e0 3,2 V. \u00c0 titre d'exemple, la tension en circuit ouvert au repos commence entre 3,35 V et 3,40 V, passe ensuite par un plateau \u00e0 deux phases, \u00e0 titre d\u2019exemple, compris entre environ 3,20 V et 3,32 V jusqu\u2019au milieu de la courbe de d\u00e9charge, puis chute brusquement vers la tension de coupure inf\u00e9rieure vers la fin de la d\u00e9charge. Par cons\u00e9quent, l\u2019\u00e9nergie de d\u00e9charge r\u00e9elle mesur\u00e9e (\u222b V(t)I(t) dt) varie en fonction de la puissance de d\u00e9charge et de la temp\u00e9rature.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-81c9ab4d auto-h3 elementor-widget elementor-widget-heading\" data-id=\"81c9ab4d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Pourquoi la capacit\u00e9 nominale et l'\u00e9nergie disponible varient-elles en fonction des taux C et P ?<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-824f17a7 auto-p elementor-widget elementor-widget-heading\" data-id=\"824f17a7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Alors que les cellules individuelles et les batteries basse tension sont souvent \u00e9valu\u00e9es en courant constant (taux C, o\u00f9 0,2 C sur une unit\u00e9 de 314 Ah \u00e9quivaut \u00e0 62,8 A et 0,5 C \u00e0 157 A), les normes de stockage destin\u00e9es aux services publics et au secteur commercial (telles que la norme GB\/T 36276-2023) \u00e9valuent g\u00e9n\u00e9ralement les cellules et les armoires de syst\u00e8mes de stockage d'\u00e9nergie par batterie (BESS) stationnaires en r\u00e9gime de puissance constante (taux P) :<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4d690cbd elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"4d690cbd\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Augmentation du courant \u00e0 puissance constante (I = P \/ V) : lorsqu'une usine utilise un syst\u00e8me de stockage d'\u00e9nergie par batterie (BESS) pour lisser un pic de demande constant en kilowatts, le syst\u00e8me de conversion de puissance (PCS) r\u00e9gule la puissance constante plut\u00f4t que le courant constant. \u00c0 mesure que la tension de cha\u00eene diminue, passant du plateau sup\u00e9rieur vers le coude de d\u00e9charge inf\u00e9rieur, le maintien d\u2019une puissance constante n\u00e9cessite que le courant continu (I = P \/ V_cha\u00eene) augmente progressivement pendant la seconde moiti\u00e9 de la d\u00e9charge.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Chauffage interne par effet Joule et chute de tension infrarouge : chaque cellule pr\u00e9sente une r\u00e9sistance interne. Sur le mod\u00e8le autonome de MegSolid <strong><a href=\"https:\/\/www.solidess.com\/fr\/bess\/technologie-des-batteries-a-etat-solide\/\" target=\"_blank\" style=\"color:#61ce70\">SHS180-314 Ah<\/a><\/strong> fiche technique de la cellule hybride solide-liquide (qui doit \u00eatre v\u00e9rifi\u00e9e par rapport \u00e0 la documentation originale de la cellule, conform\u00e9ment au contrat), la r\u00e9sistance interne en courant alternatif est de 0,18 \u00b1 0,03 m\u03a9 et la r\u00e9sistance interne en courant continu est de 0,4 \u00b1 0,1 m\u03a9, ce qui permet d\u2019atteindre un rendement \u00e9nerg\u00e9tique de la cellule \u2265 94,5 % \u00e0 0,5P. \u00c0 une puissance de d\u00e9charge plus \u00e9lev\u00e9e (par exemple, un service de r\u00e9gulation de fr\u00e9quence \u00e0 1P par rapport \u00e0 une mise en service de 0,5P pendant 2 heures), l\u2019\u00e9chauffement par r\u00e9sistance interne (I\u00b2 R_DC) et la polarisation de la tension aux bornes (I \u00d7 R_DC) augmentent.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Tension de coupure des tests de cellule par rapport \u00e0 la plage de tension de fonctionnement du syst\u00e8me : sous charge, la tension aux bornes est \u00e9gale \u00e0 la tension en circuit ouvert moins la polarisation r\u00e9sistive (V_term = V_OCV - I \u00d7 R_DC), ce qui fait que des d\u00e9bits de d\u00e9charge plus \u00e9lev\u00e9s atteignent plus t\u00f4t la tension de coupure inf\u00e9rieure. Il est essentiel que les ing\u00e9nieurs distinguent les tensions de coupure mesur\u00e9es au niveau de la cellule des plages de tension de fonctionnement du BMS au niveau du syst\u00e8me :<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">\u2014 Alors que la fiche technique de la cellule SHS180-314Ah seule d\u00e9finit une plage de tension d'essai comprise entre 2,50 V et 3,65 V (au-dessus de 0 \u00b0C), les batteries MegSolid compl\u00e8tes fonctionnent dans des plages de tension syst\u00e8me plus \u00e9troites afin de pr\u00e9server leur dur\u00e9e de vie.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">\u2014 Plus pr\u00e9cis\u00e9ment, le <strong><a href=\"https:\/\/www.solidess.com\/fr\/product\/batterie-de-stockage-denergie-solide-megsold\/\" target=\"_blank\" style=\"color:#61ce70\">MEG-Solid-512314FL1<\/a><\/strong> (51,2 V \/ 314 Ah) fonctionne entre 43,2 V et 57,6 V (ce qui correspond \u00e0 une tension moyenne d'environ 2,70 V \u00e0 3,60 V par cellule sur une cha\u00eene suppos\u00e9e de 16 cellules), et l\u2019Energon (261,24 kWh) fonctionne dans une plage comprise entre 676 V et 936 V (ce qui correspond \u00e0 une tension comprise entre 2,60 V et 3,60 V par cellule sur sa cha\u00eene 1P260S). Par cons\u00e9quent, les limites d\u2019essai de 2,50 V \u00e0 3,65 V au niveau des cellules ne doivent en aucun cas \u00eatre consid\u00e9r\u00e9es comme la plage de coupure du BMS au niveau du pack pour tous les syst\u00e8mes MegSolid.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8b29b0e6 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"8b29b0e6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Lithium ou plomb-acide : comparaison entre la capacit\u00e9 nominale et l'\u00e9nergie utile<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5678d98f auto-p elementor-widget elementor-widget-heading\" data-id=\"5678d98f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Dans le cadre des demandes de renseignements concernant les syst\u00e8mes solaires r\u00e9sidentiels de secours et les installations commerciales hors r\u00e9seau, les acheteurs se posent souvent la question suivante : qu'est-ce qui est le mieux, une batterie au lithium ou une batterie haute capacit\u00e9 ?<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a1bae19e auto-image elementor-widget elementor-widget-image\" data-id=\"a1bae19e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"1536\" height=\"1024\" src=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/lead-acid-vs-lfp-usable-energy-comparison-1536x1024.webp\" class=\"attachment-1536x1536 size-1536x1536 wp-image-7949\" alt=\"Comparaison illustrative entre l&#039;\u00e9nergie d&#039;une batterie au plomb de 48 V et 200 Ah \u00e0 50 % de profondeur de d\u00e9charge (DoD) et celle d&#039;une batterie LiFePO\u2084 de 51,2 V et 314 Ah \u00e0 80 % de profondeur de d\u00e9charge (DoD)\" srcset=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/lead-acid-vs-lfp-usable-energy-comparison-1536x1024.webp 1536w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/lead-acid-vs-lfp-usable-energy-comparison-300x200.webp 300w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/lead-acid-vs-lfp-usable-energy-comparison-1024x683.webp 1024w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/lead-acid-vs-lfp-usable-energy-comparison-768x512.webp 768w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/lead-acid-vs-lfp-usable-energy-comparison-18x12.webp 18w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/lead-acid-vs-lfp-usable-energy-comparison-600x400.webp 600w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/lead-acid-vs-lfp-usable-energy-comparison.webp 1920w\" sizes=\"(max-width: 1536px) 100vw, 1536px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-571fd4b2 auto-p elementor-widget elementor-widget-heading\" data-id=\"571fd4b2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">\u00c9tant donn\u00e9 que les notions de \" batterie au lithium \" (une famille de technologies \u00e9lectrochimiques) et de \" batterie haute capacit\u00e9 \" (\u00e0 l\u2019\u00e9chelle de l\u2019amp\u00e8re-heure ou du kilowattheure) ne s\u2019excluent pas mutuellement, cette question trouve son origine dans le fait que les distributeurs traditionnels de syst\u00e8mes solaires comparent une \" batterie au plomb-acide haute capacit\u00e9 de 200 Ah (AGM\/Gel) \" \u00e0 une \" batterie au lithium (LiFePO\u2084) de 100 Ah \". L\u2019\u00e9valuation de la capacit\u00e9 nominale par rapport \u00e0 l\u2019\u00e9nergie utilisable entre ces technologies met en \u00e9vidence trois diff\u00e9rences techniques :<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-bd583656 auto-h3 elementor-widget elementor-widget-heading\" data-id=\"bd583656\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">1. Gestion pratique de la profondeur de d\u00e9charge (profondeur de d\u00e9charge de 80 % ou plus pour le lithium, contre 50 % habituellement pour les batteries au plomb)<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-090c3cd9 auto-p elementor-widget elementor-widget-heading\" data-id=\"090c3cd9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Bien que les batteries au plomb-acide puissent physiquement se d\u00e9charger en dessous de 50 % de leur \u00e9tat de charge (SoC) en cas d\u2019urgence, les cycles de d\u00e9charge profonde r\u00e9guliers en dessous de 50 % de profondeur de d\u00e9charge (DoD) acc\u00e9l\u00e8rent la cristallisation du sulfate de plomb et la corrosion des grilles. Dans le cadre d\u2019une strat\u00e9gie courante de gestion du cycle de vie visant \u00e0 atteindre 400 \u00e0 800 cycles, les ing\u00e9nieurs sp\u00e9cialis\u00e9s dans les syst\u00e8mes hors r\u00e9seau limitent g\u00e9n\u00e9ralement les batteries au plomb-acide \u00e0 un DO \u00e0 50 % par jour, ce qui signifie qu\u2019un banc de batteries au plomb-acide de 200 Ah fournit environ 100 Ah de charge par cycle quotidien de routine. En revanche, les unit\u00e9s au lithium fer phosphate et les unit\u00e9s hybrides \u00e0 l\u2019\u00e9tat solide LFP sont con\u00e7ues pour des cycles \u00e0 long terme \u00e0 un taux de d\u00e9charge (DoD) compris entre 80 % et 100 % (par exemple, 8 000 cycles \u00e0 80 % de DoD sur le mod\u00e8le MEG-Solid-512314FL1 ou \u2265 6 000 cycles \u00e0 80 % de la capacit\u00e9 de fin de vie (EOL) sur le <strong><a href=\"https:\/\/www.solidess.com\/fr\/product\/bloc-batterie-au-lithium-amovible\/\" target=\"_blank\" style=\"color:#61ce70\">MG 512314<\/a><\/strong>).<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-384b4313 auto-h3 elementor-widget elementor-widget-heading\" data-id=\"384b4313\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">2. Comportement en d\u00e9charge \u00e0 courant \u00e9lev\u00e9 et plages de r\u00e9f\u00e9rence de l'effet Peukert<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8a4999b6 auto-p elementor-widget elementor-widget-heading\" data-id=\"8a4999b6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Les fiches techniques des batteries au plomb indiquent g\u00e9n\u00e9ralement la capacit\u00e9 nominale lors d'une d\u00e9charge lente de 20 heures (0,05 C, soit 10 A pour un banc de 200 Ah). Selon la relation empirique de Peukert (t = H (C \/ (I \u00d7 H))^k), les valeurs de r\u00e9f\u00e9rence couramment cit\u00e9es dans la litt\u00e9rature pour l\u2019exposant k de Peukert se situent entre 1,15 et 1,30 pour les cellules au plomb-acide, contre environ 1,01 \u00e0 1,03 pour les cellules lithium-ion (les exposants exacts varient en fonction de la construction des plaques, de la temp\u00e9rature et du mod\u00e8le). Lorsqu\u2019un onduleur absorbe une charge de pointe de 0,5 C, les limitations li\u00e9es \u00e0 la diffusion de l\u2019acide \u00e0 l\u2019int\u00e9rieur des plaques de plomb poreuses entra\u00eenent une chute rapide de la tension aux bornes vers le seuil de coupure basse tension de l\u2019onduleur, ce qui r\u00e9duit l\u2019\u00e9nergie effective d\u00e9livrable en un seul cycle par rapport \u00e0 la capacit\u00e9 nominale sur 20 heures.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9895b2e9 auto-h3 elementor-widget elementor-widget-heading\" data-id=\"9895b2e9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">3. Capacit\u00e9s des cellules sp\u00e9cifiques \u00e0 chaque mod\u00e8le dans l'ensemble de la gamme de produits MegSolid<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-30ffc089 auto-p elementor-widget elementor-widget-heading\" data-id=\"30ffc089\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Les syst\u00e8mes modernes de stockage au lithium associent l'\u00e9lectrochimie du lithium \u00e0 des capacit\u00e9s nominales \u00e9lev\u00e9es en amp\u00e8res-heures par cellule ; toutefois, les acheteurs doivent v\u00e9rifier la capacit\u00e9 exacte attribu\u00e9e \u00e0 chaque gamme de produits MegSolid, plut\u00f4t que de supposer que tous les syst\u00e8mes utilisent le m\u00eame type de cellule :<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e2717a5f elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"e2717a5f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Syst\u00e8mes r\u00e9sidentiels 51,2 V 314 Ah : le MEG-Solid-512314FL1 (51,2 V \/ 314 Ah \/ 16,07 kWh) et le MG 512314 (51,2 V \/ 314 Ah \/ 16 076 Wh, unit\u00e9 mobile pouvant prendre en charge jusqu\u2019\u00e0 6 unit\u00e9s en parall\u00e8le) utilisent des cellules de 314 Ah. (Remarque : l'extension en parall\u00e8le jusqu'\u00e0 6 unit\u00e9s est officiellement sp\u00e9cifi\u00e9e pour le mod\u00e8le MG 512314 ; la capacit\u00e9 de mise en parall\u00e8le du mod\u00e8le MEG-Solid-512314FL1 n'est pas mentionn\u00e9e dans la fiche technique g\u00e9n\u00e9rale et doit \u00eatre confirm\u00e9e aupr\u00e8s de MegSolid au cas par cas.)<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Armoires ext\u00e9rieures C&amp;I (ESSA vs Energon) : Dans la gamme C&amp;I de MegSolid, le <strong><a href=\"https:\/\/www.solidess.com\/fr\/product\/systeme-de-stockage-denergie-en-armoire-exterieure\/\" target=\"_blank\" style=\"color:#61ce70\">ESSA0100B-0215<\/a><\/strong> (100 kW \/ 215,04 kWh) utilise des cellules LFP standard de 280 Ah (avec, en option, des configurations \u00e0 semi-conducteurs sp\u00e9cifiques au projet), tandis que le mod\u00e8le Energon \u00e0 refroidissement liquide (125 kVA \/ 261,24 kWh), refroidi par liquide, utilise des cellules LFP standard de 314 Ah dispos\u00e9es en cha\u00eene 1P260S.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Conteneur utilitaire (5000INTL) : Le conteneur 5000INTL, d'une capacit\u00e9 de 5 015,9 kWh \/ 2 700 kW, mentionne le code de type de batterie \u00ab SHS180-314 \u00bb dans son tableau syst\u00e8me ; l'architecture exacte de l'\u00e9lectrolyte des cellules et les d\u00e9tails techniques d'un contrat de conteneur donn\u00e9 doivent \u00eatre v\u00e9rifi\u00e9s directement aupr\u00e8s de MegSolid plut\u00f4t que d'\u00eatre d\u00e9duits uniquement \u00e0 partir du code de type.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f3f05253 auto-p elementor-widget elementor-widget-heading\" data-id=\"f3f05253\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Le tableau 2 compare un parc de batteries au plomb-acide traditionnel de 48 V et 200 Ah \u00e0 une unit\u00e9 LFP classique de 51,2 V et 100 Ah, ainsi qu'aux deux mod\u00e8les de stockage MegSolid de 51,2 V et 314 Ah.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-cde378d0 auto-h3 elementor-widget elementor-widget-heading\" data-id=\"cde378d0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Tableau 2 : Comparaison entre les batteries au plomb-acide de 48 V, les batteries LFP de 51,2 V et 100 Ah et les batteries MegSolid de 51,2 V et 314 Ah<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a2001148 auto-table elementor-widget elementor-widget-text-editor\" data-id=\"a2001148\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"cea-table-wrap\"><table><thead><tr><th>Param\u00e8tre de comparaison<\/th><th>Batterie au plomb-acide de 48 V et 200 Ah (g\u00e9n\u00e9ralement de type AGM\/gel)<\/th><th>Batterie LFP standard de 51,2 V et 100 Ah (secteur industriel)<\/th><th>MEG-Solid-512314FL1 (semi-conducteur hybride)<\/th><th>MG 512314 (Logement mobile)<\/th><\/tr><\/thead><tbody><tr><td>Capacit\u00e9 d\u00e9clar\u00e9e et \u00e9nergie nominale<\/td><td>200 Ah (\u00e0 C\u2082\u2080) \/ 9,60 kWh<\/td><td>100 Ah \/ 5,12 kWh<\/td><td>314 Ah \/ 16,07 kWh (43,2\u201357,6 V)<\/td><td>314 Ah \/ 16 076 Wh (40\u201358,4 V)<\/td><\/tr><tr><td>Strat\u00e9gie quotidienne type du minist\u00e8re de la D\u00e9fense<\/td><td>Environ 50 % de la profondeur de d\u00e9charge (DoD) : pratique courante pour la dur\u00e9e de vie du cycle<\/td><td>80 % \u00e0 90 % de profondeur de d\u00e9charge (DoD)<\/td><td>80 % de la valeur de r\u00e9f\u00e9rence du cycle selon le DoD<\/td><td>80 % de la valeur de r\u00e9f\u00e9rence du cycle EOL (\u00e0 25 \u00b0C)<\/td><\/tr><tr><td>Exemple d'\u00e9nergie utilisable en courant continu (\u00e0 80 % \/ 50 % de profondeur de d\u00e9charge)<\/td><td>~4,80 kWh \u00e0 0,05 C (ce chiffre diminue \u00e0 des taux de charge plus \u00e9lev\u00e9s, en fonction de la tension de coupure et de la temp\u00e9rature)<\/td><td>~4,10 kWh en courant continu \u00e0 80 % de profondeur de d\u00e9charge (DoD)<\/td><td>~12,86 kWh en courant continu \u00e0 80 % de profondeur de d\u00e9charge (~11,57 kWh en courant alternatif avec un rendement suppos\u00e9 de 90 %)<\/td><td>~12,86 kWh en courant continu \u00e0 80 % de profondeur de d\u00e9charge (montage en parall\u00e8le jusqu'\u00e0 6 unit\u00e9s \/ 96,46 kWh nominaux)<\/td><\/tr><tr><td>Dur\u00e9e de vie nominale<\/td><td>400 \u00e0 800 cycles (valeur typique \u00e0 50 % de profondeur de d\u00e9charge)<\/td><td>4 000 \u00e0 6 000 cycles (\u00e0 80 % de profondeur de d\u00e9charge)<\/td><td>8 000 cycles \u00e0 80 % de profondeur de d\u00e9charge (DoD)<\/td><td>\u2265 6 000 cycles (\u00e0 25 \u00b0C, 80 % de la dur\u00e9e de vie utile)<\/td><\/tr><tr><td>Courant de charge \/ d\u00e9charge et imp\u00e9dance<\/td><td>20 A \u00e0 40 A en service continu typique<\/td><td>G\u00e9n\u00e9ralement de 50 A \u00e0 100 A<\/td><td>Charge maximale de 200 A \/ d\u00e9charge continue de 200 A ; \u2264 15 m\u03a9<\/td><td>Charge maximale de 200 A \/ d\u00e9charge maximale de 200 A ; r\u00e9sistance d'ensemble \u2264 80 m\u03a9<\/td><\/tr><\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d3de4a38 auto-p elementor-widget elementor-widget-heading\" data-id=\"d3de4a38\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Note technique concernant les intensit\u00e9s nominales du tableau 2 :<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-99b7201f elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"99b7201f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Calcul du courant continu par rapport au courant maximal et de la puissance nominale en courant continu : Dans les fiches techniques officielles, le mod\u00e8le MEG-Solid-512314FL1 sp\u00e9cifie un courant de charge maximal de 200 A et un courant de d\u00e9charge continu de 200 A, tandis que le tableau du mod\u00e8le MG 512314 indique un courant de charge maximal de 200 A et un courant de d\u00e9charge maximal de 200 A sans pr\u00e9ciser de valeur distincte pour le courant de d\u00e9charge continu. La multiplication de 200 A \u00d7 51,2 V = 10,24 kW ne repr\u00e9sente que la puissance continue th\u00e9orique \u00e0 la tension nominale ; la puissance de sortie alternative continue r\u00e9elle d\u00e9pend de la tension aux bornes sous charge, des limites thermiques en continu et du rendement de l'onduleur hybride.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-88675527 elementor-tablet-align-center elementor-align-center auto-cta elementor-widget elementor-widget-button\" data-id=\"88675527\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"#elementor-action%3Aaction%3Dpopup%3Aopen%26settings%3DeyJpZCI6Ijk0OCIsInRvZ2dsZSI6ZmFsc2V9\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Contactez-nous pour une analyse de la capacit\u00e9 nominale et des conditions d'essai<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-33aa1fe9 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"33aa1fe9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">4 facteurs techniques qui influencent la capacit\u00e9 effective des syst\u00e8mes de stockage d'\u00e9nergie par batterie (BESS) sur le terrain<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4913fa16 auto-p elementor-widget elementor-widget-heading\" data-id=\"4913fa16\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">En conditions r\u00e9elles d'exploitation, l'\u00e9nergie disponible d'une armoire commerciale ou d'un parc de batteries r\u00e9sidentiel d\u00e9pend des seuils de coupure de tension des cha\u00eenes en s\u00e9rie, de l'imp\u00e9dance interne, de la polarisation due \u00e0 la temp\u00e9rature ambiante et des d\u00e9finitions de l'\u00e9tat de sant\u00e9 (SOH) en fin de vie (EOL).<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9795c564 auto-h3 elementor-widget elementor-widget-heading\" data-id=\"9795c564\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">1. Dynamique de coupure des cha\u00eenes en s\u00e9rie (\" effet de baril \") et uniformit\u00e9 thermique<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9a82ee02 auto-p elementor-widget elementor-widget-heading\" data-id=\"9a82ee02\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Dans une armoire commerciale haute tension telle que celle de 261,24 kWh <strong><a href=\"https:\/\/www.solidess.com\/fr\/product\/stockage-denergie-solide-liquide-megasolide\/\" target=\"_blank\" style=\"color:#61ce70\">Energon<\/a><\/strong> (qui relie 260 cellules LFP de 314 Ah dans un montage en s\u00e9rie de type 1P260S fonctionnant entre 676 V et 936 V CC), les 260 cellules transportent toutes exactement le m\u00eame courant en s\u00e9rie :<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-086085e8 elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"086085e8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Interruption de la charge d\u00e8s qu\u2019une cellule atteint le seuil sup\u00e9rieur d\u00e9fini par le BMS : pendant la charge, le BMS de la cha\u00eene interrompt ou r\u00e9duit progressivement le courant de charge d\u00e8s qu\u2019une cellule, parmi toutes celles de la cha\u00eene, atteint le seuil sup\u00e9rieur de tension d\u00e9fini par le BMS, m\u00eame si d\u2019autres cellules de la cha\u00eene pr\u00e9sentent un \u00e9tat de charge inf\u00e9rieur. (Remarque : dans les cellules LFP, la tension aux bornes pendant la charge ou la d\u00e9charge active ne peut pas \u00eatre mise en correspondance avec un pourcentage de SOC fixe sans tenir compte de la polarisation li\u00e9e au taux de charge (C-rate), de la temp\u00e9rature et de l'hyst\u00e9r\u00e9sis au repos.)<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Interruption de la d\u00e9charge par la premi\u00e8re cellule atteignant le seuil inf\u00e9rieur du BMS : pendant la d\u00e9charge, le BMS d\u00e9connecte la cha\u00eene d\u00e8s que la cellule la plus faible ou la plus froide atteint le seuil inf\u00e9rieur de tension de coupure, laissant ainsi de la charge inutilis\u00e9e dans les 259 cellules restantes.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Att\u00e9nuer le vieillissement diff\u00e9rentiel gr\u00e2ce au refroidissement par liquide : les temp\u00e9ratures \u00e9lev\u00e9es des cellules acc\u00e9l\u00e9rant la formation de la couche d\u2019\u00e9lectrolyte solide (SEI), les gradients de temp\u00e9rature au sein d\u2019une longue cha\u00eene de cellules entra\u00eenent une perte de capacit\u00e9 plus rapide des cellules les plus chaudes que des cellules plus froides. L'application d'un refroidissement par liquide sur l'armoire Energon (261,24 kWh) et d'un refroidisseur \u00e0 liquide sur le <strong><a href=\"https:\/\/www.solidess.com\/fr\/product\/systeme-de-stockage-denergie-conteneurise-megasolid-5000intl\/\" target=\"_blank\" style=\"color:#61ce70\">5000INTL<\/a><\/strong> Le conteneur (5 015,9 kWh) permet de maintenir une plus grande homog\u00e9n\u00e9it\u00e9 de temp\u00e9rature d'une cellule \u00e0 l'autre sur l'ensemble de la cha\u00eene qu'avec de l'air non conditionn\u00e9.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5fc4407f auto-h3 elementor-widget elementor-widget-heading\" data-id=\"5fc4407f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">2. Imp\u00e9dance interne et chute de tension due \u00e0 la charge<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d25e6fa5 auto-p elementor-widget elementor-widget-heading\" data-id=\"d25e6fa5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Lorsqu'un onduleur alimente des charges \u00e0 fort courant, la r\u00e9sistance interne provoque une chute de tension imm\u00e9diate (\u0394 V = I \u00d7 R_interne) :<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9c71e3bf elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"9c71e3bf\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Imp\u00e9dance au niveau de la cellule : Dans sa fiche technique d\u00e9di\u00e9e, la cellule hybride solide-liquide SHS180-314Ah pr\u00e9sente une r\u00e9sistance en courant alternatif de 0,18 \u00b1 0,03 m\u03a9 et une r\u00e9sistance en courant continu de 0,4 \u00b1 0,1 m\u03a9.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Limite d'imp\u00e9dance au niveau de l'unit\u00e9 : sur le mod\u00e8le MEG-Solid-512314FL1 (51,2 V \/ 314 Ah), l'imp\u00e9dance interne est sp\u00e9cifi\u00e9e \u00e0 \u2264 15 m\u03a9 (et une imp\u00e9dance d\u2019ensemble \u2264 80 m\u03a9 sur le mod\u00e8le MG 512314). Bien qu\u2019une faible imp\u00e9dance interne minimise la chute de tension r\u00e9sistive lors d\u2019une forte consommation de courant, la capacit\u00e9 d\u2019une unit\u00e9 \u00e0 supporter une charge de 200 A sans atteindre son seuil de coupure en cas de basse tension (43,2 V sur le mod\u00e8le MEG-Solid-512314FL1 ou 40,0 V sur le MG 512314) d\u00e9pend \u00e9galement de l\u2019\u00e9tat de charge instantan\u00e9, de la temp\u00e9rature des cellules et des temporisateurs de protection du BMS.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c8f46cd7 auto-h3 elementor-widget elementor-widget-heading\" data-id=\"c8f46cd7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">3. Polarisation de tension \u00e0 basse temp\u00e9rature par rapport aux limites de charge<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-262890aa auto-p elementor-widget elementor-widget-heading\" data-id=\"262890aa\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Les temp\u00e9ratures ambiantes basses augmentent la viscosit\u00e9 de l'\u00e9lectrolyte et ralentissent la diffusion des ions lithium, ce qui accro\u00eet la r\u00e9sistance interne et la polarisation de tension pendant la d\u00e9charge :<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b358d945 elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"b358d945\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">R\u00e9glage de la coupure de d\u00e9charge en dessous de z\u00e9ro : Sur la fiche technique de la cellule autonome SHS180-314Ah, la plage de tension de fonctionnement est indiqu\u00e9e comme \u00e9tant comprise entre 2,5 V et 3,65 V au-dessus de 0 \u00b0C et s'\u00e9tend de 2,0 V \u00e0 3,65 V \u00e0 0 \u00b0C ou en dessous. L'abaissement du seuil de coupure de d\u00e9charge en dessous de z\u00e9ro \u00e0 2,0 V compense la polarisation r\u00e9sistive plus prononc\u00e9e observ\u00e9e lors de la d\u00e9charge \u00e0 froid, afin que l'\u00e9nergie utilisable ne soit pas coup\u00e9e pr\u00e9matur\u00e9ment. (Remarque : le placage de lithium est un ph\u00e9nom\u00e8ne distinct qui se produit lors de la charge \u00e0 basse temp\u00e9rature et doit \u00eatre \u00e9vit\u00e9 gr\u00e2ce \u00e0 des limites de temp\u00e9rature de charge d\u00e9finies dans le BMS, \u00e0 une r\u00e9duction du courant de charge et \u00e0 un chauffage d'appoint.)<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Plages de temp\u00e9rature de fonctionnement du syst\u00e8me : au niveau du syst\u00e8me, la s\u00e9rie d\u2019armoires ESSA pour usage ext\u00e9rieur C&amp;I fonctionne entre 0 \u00b0C et +45 \u00b0C, l\u2019armoire Energon \u00e0 refroidissement par liquide fonctionne entre -20 \u00b0C et +55 \u00b0C (avec un d\u00e9classement de la puissance au-del\u00e0 de 45 \u00b0C), et la <strong><a href=\"https:\/\/www.solidess.com\/fr\/product\/onduleur-de-stockage-denergie-megasolid\/\" target=\"_blank\" style=\"color:#61ce70\">PMA<\/a><\/strong> La s\u00e9rie PCS modulaire fonctionne entre -30 \u00b0C et +60 \u00b0C (d\u00e9classement au-del\u00e0 de 45 \u00b0C).<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b12b42f6 auto-h3 elementor-widget elementor-widget-heading\" data-id=\"b12b42f6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">4. Seuils de l'\u00e9tat de sant\u00e9 (SOH) en fin de vie (EOL) (80 % de SOH contre 70 % de SOH)<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d5856b81 auto-p elementor-widget elementor-widget-heading\" data-id=\"d5856b81\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Lorsqu'ils \u00e9valuent les dur\u00e9es de vie nominales, les ing\u00e9nieurs doivent v\u00e9rifier la limite relative \u00e0 l'\u00e9tat de sant\u00e9 en fin de vie (SOH_EOL) d\u00e9finie dans la fiche technique :<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-80ee9d7c elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"80ee9d7c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Sp\u00e9cifications de la cellule autonome SHS180-314Ah : 6 000 cycles jusqu'\u00e0 \u2265 80 % de SOH (\u00e0 0,5P\/0,5P, 100 % de DoD). Dans des conditions th\u00e9oriques o\u00f9 les autres variables restent constantes, 80 % d'une capacit\u00e9 nominale initiale de 314 Ah correspondent \u00e0 une capacit\u00e9 restante de 251,2 Ah.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Sp\u00e9cifications de la cellule autonome SHS165-280Ah : \u2265 8 000 cycles jusqu'\u00e0 \u2265 70 % de SOH (\u00e0 0,5P\/0,5P, 100 % de DoD \u00e0 temp\u00e9rature ambiante).<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Remarque relative \u00e0 la v\u00e9rification obligatoire : \u00e9tant donn\u00e9 que les niveaux de SOH de 80 % et 70 % correspondent \u00e0 des seuils de perte de capacit\u00e9 cumulative diff\u00e9rents, les deux nombres de cycles ne peuvent pas \u00eatre compar\u00e9s directement l\u2019un par rapport \u00e0 l\u2019autre sans \u00eatre normalis\u00e9s par rapport au m\u00eame seuil de SOH en fin de vie (EOL). De plus, les fiches techniques des cellules individuelles pour les mod\u00e8les SHS180-314Ah et SHS165-280Ah \u00e9tant distinctes du catalogue g\u00e9n\u00e9ral des syst\u00e8mes disponible sur le site web (llms-full.txt), les acheteurs doivent demander les documents originaux de sp\u00e9cifications des cellules et v\u00e9rifier quel mod\u00e8le de cellule est pr\u00e9cis\u00e9ment configur\u00e9 dans le syst\u00e8me faisant l'objet de leur contrat.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-cee7b60d auto-h2 elementor-widget elementor-widget-heading\" data-id=\"cee7b60d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Comment d\u00e9terminer la puissance install\u00e9e par rapport \u00e0 la puissance utile de climatisation pour les projets C&amp;I et r\u00e9sidentiels<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-dca0130a auto-p elementor-widget elementor-widget-heading\" data-id=\"dca0130a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Pour calculer l'\u00e9nergie install\u00e9e requise en d\u00e9but de vie (BOL) (E_installed_required) n\u00e9cessaire pour garantir une charge CA nette cible (E_target_AC_load), les ing\u00e9nieurs utilisent la formule de dimensionnement suivante :<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2a929f49 auto-image elementor-widget elementor-widget-image\" data-id=\"2a929f49\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"1536\" height=\"1024\" src=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/capacity-ladder-ah-to-usable-ac-kwh-1536x1024.webp\" class=\"attachment-1536x1536 size-1536x1536 wp-image-7948\" alt=\"Sch\u00e9ma en \u00e9chelle de la capacit\u00e9 de la batterie indiquant une capacit\u00e9 nominale de 314 Ah, une \u00e9nergie nominale de 261,24 kWh, l&#039;\u00e9nergie de d\u00e9charge mesur\u00e9e et, \u00e0 titre indicatif, une \u00e9nergie utile en courant alternatif de 188,09 kWh\" srcset=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/capacity-ladder-ah-to-usable-ac-kwh-1536x1024.webp 1536w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/capacity-ladder-ah-to-usable-ac-kwh-300x200.webp 300w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/capacity-ladder-ah-to-usable-ac-kwh-1024x683.webp 1024w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/capacity-ladder-ah-to-usable-ac-kwh-768x512.webp 768w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/capacity-ladder-ah-to-usable-ac-kwh-18x12.webp 18w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/capacity-ladder-ah-to-usable-ac-kwh-600x400.webp 600w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/capacity-ladder-ah-to-usable-ac-kwh.webp 1920w\" sizes=\"(max-width: 1536px) 100vw, 1536px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-56d56484 auto-p elementor-widget elementor-widget-heading\" data-id=\"56d56484\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">E_install\u00e9e_requise = E_charge_CA_cible \/ (DoD_de_conception \u00d7 \u03b7_del \u00d7 SOH_cible)<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-921e312c auto-p elementor-widget elementor-widget-heading\" data-id=\"921e312c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Le tableau 3 pr\u00e9sente un aper\u00e7u des plateformes officielles de stockage de MegSolid destin\u00e9es aux particuliers, au secteur C&amp;I et aux services publics, ainsi que leurs configurations confirm\u00e9es en termes de tension et de cellules et leurs limites de rendement.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-faf18b14 auto-h3 elementor-widget elementor-widget-heading\" data-id=\"faf18b14\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Tableau 3 : Matrice de r\u00e9f\u00e9rence des capacit\u00e9s de stockage MegSolid pour les secteurs r\u00e9sidentiel, C&amp;I et des services publics<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4154d04c auto-table elementor-widget elementor-widget-text-editor\" data-id=\"4154d04c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"cea-table-wrap\"><table><thead><tr><th>Plateforme MegSolid<\/th><th>Configuration des cellules et des cordes<\/th><th>Puissance nominale indiqu\u00e9e sur la plaque signal\u00e9tique<\/th><th>Exemple de rapport BOL : \u00e9nergie AC (profondeur de d\u00e9charge de 80 %, rendement suppos\u00e9 de 90 %)<\/th><th>Notes officielles sur l'efficacit\u00e9 et les applications<\/th><\/tr><\/thead><tbody><tr><td>MEG-Solid-512314FL1 (hybride \u00e0 semi-conducteurs, 51,2 V)<\/td><td>Batterie hybride LFP \u00e0 semi-conducteurs de 314 Ah (capacit\u00e9 estim\u00e9e \u00e0 16 S \u00e0 partir d'une tension nominale de 51,2 V ; plage de tension : 43,2\u201357,6 V)<\/td><td>16,07 kWh \/ 51,2 V (charge maximale de 200 A et d\u00e9charge continue)<\/td><td>11,57 kWh (\u00e0 titre indicatif pour une seule unit\u00e9)<\/td><td>Options IP21\/IP65 \u00e0 pr\u00e9ciser lors de la commande ; v\u00e9rifier les r\u00e8gles de montage en parall\u00e8le et le rendement des onduleurs pour chaque projet<\/td><\/tr><tr><td>MG 512314 Unit\u00e9 r\u00e9sidentielle mobile<\/td><td>Cellule de 314 Ah (16 S d\u00e9duit d'une tension nominale de 51,2 V ; 40\u201358,4 V ; jusqu'\u00e0 6 unit\u00e9s en parall\u00e8le)<\/td><td>16 076 Wh par unit\u00e9 (jusqu'\u00e0 96,46 kWh en valeur nominale pour 6 unit\u00e9s)<\/td><td>11,57 kWh par unit\u00e9 (69,45 kWh pour 6 unit\u00e9s en parall\u00e8le)<\/td><td>Syst\u00e8me de stockage r\u00e9sidentiel mobile IP21 ; intensit\u00e9 maximale de charge\/d\u00e9charge : 200 A<\/td><\/tr><tr><td>Armoire C&amp;I ext\u00e9rieure ESSA0100B-0215<\/td><td>280 Ah LFP standard (batterie \u00e0 semi-conducteurs en option selon le contrat ; 672\u2013850 V CC)<\/td><td>215,04 kWh \/ 100 kW (0,5C ; la gamme ESSA s'\u00e9tend de 55,3 \u00e0 215,04 kWh)<\/td><td>154,83 kWh par armoire<\/td><td>400 V CA, de 0 \u00b0C \u00e0 +45 \u00b0C, IP54 ; transformateur d'isolement int\u00e9gr\u00e9<\/td><\/tr><tr><td>Armoire Energon \u00e0 refroidissement liquide LFP C&amp;I<\/td><td>Cha\u00eene 1P260S compos\u00e9e de cellules LFP standard de 314 Ah (676\u2013936 V CC ; jusqu\u2019\u00e0 10 unit\u00e9s)<\/td><td>261,24 kWh \/ 125 kVA (832 V CC nominal ; 400 V CA)<\/td><td>188,09 kWh (\u00e0 80 % de profondeur de d\u00e9charge ; 211,60 kWh \u00e0 90 % de profondeur de d\u00e9charge)<\/td><td>Rendement maximal : 90 % (valeur maximale indiqu\u00e9e dans la fiche technique) ; de -20 \u00b0C \u00e0 +55 \u00b0C (r\u00e9duction de la puissance au-del\u00e0 de 45 \u00b0C)<\/td><\/tr><tr><td>Conteneur polyvalent 5000INTL de 20 pieds<\/td><td>R\u00e9pertorie le code de type de batterie SHS180-314 (1 123,2 \u00e0 1 497,6 V CC ; 1 331,2 V nominal)<\/td><td>5 015,9 kWh \/ 2 700 kW (450 kW \u00d7 6 \u00e9tages \u00e0 690 V CA)<\/td><td>\u00c0 confirmer en fonction de la courbe de rendement du projet et de la charge auxiliaire du groupe frigorifique<\/td><td>Rendement maximal officiel : 87,5 % (valeur maximale indiqu\u00e9e dans la fiche technique) ; groupe frigorifique \u00e0 refroidissement par liquide, indice de protection IP55<\/td><\/tr><\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5e214fe0 auto-p elementor-widget elementor-widget-heading\" data-id=\"5e214fe0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Remarques techniques importantes concernant le tableau 3 :<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3aa13b29 elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"3aa13b29\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Pourquoi 5000INTL ne devrait pas se baser sur une hypoth\u00e8se de rendement de 90 % : Bien que, math\u00e9matiquement, 5 015,9 kWh \u00d7 0,80 \u00d7 0,90 donne 3 611,45 kWh, la fiche technique officielle de MegSolid pour le conteneur 5000INTL indique un rendement maximal de 87,5 %. Utiliser une hypoth\u00e8se de rendement de livraison de 90 %, qui d\u00e9passe le rendement maximal publi\u00e9 de 87,5 % de l'unit\u00e9, conduirait \u00e0 une surestimation de l'\u00e9nergie en courant alternatif livrable. Dans la pratique, les ing\u00e9nieurs EPC doivent mod\u00e9liser l\u2019\u00e9nergie livrable du 5000INTL en utilisant un rendement de livraison prudent, v\u00e9rifi\u00e9 sur le projet, inf\u00e9rieur au plafond maximal de 87,5 % (apr\u00e8s d\u00e9duction de la consommation parasite du refroidisseur \u00e0 liquide et des pertes du transformateur \u00e9l\u00e9vateur).<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Condition \u00ab ceteris paribus \u00bb pour le dimensionnement de la capacit\u00e9 en fin de vie : Dans des conditions th\u00e9oriques o\u00f9 la temp\u00e9rature, le taux de d\u00e9charge (C-rate), la r\u00e9sistance interne et les charges auxiliaires restent inchang\u00e9es (ceteris paribus), un syst\u00e8me de batterie atteignant un seuil de fin de vie correspondant \u00e0 80 % de son \u00e9tat de sant\u00e9 (SOH) subit une r\u00e9duction de 20 % de l\u2019\u00e9nergie d\u00e9livrable par cycle par rapport \u00e0 sa valeur de r\u00e9f\u00e9rence en d\u00e9but de vie. \u00c9tant donn\u00e9 que l\u2019imp\u00e9dance des cellules augmente g\u00e9n\u00e9ralement \u00e0 mesure que le SOH diminue, les ing\u00e9nieurs doivent pr\u00e9voir une marge suppl\u00e9mentaire ou un plan d\u2019augmentation programm\u00e9 lorsqu\u2019ils garantissent la puissance de sortie CA \u00e0 la dixi\u00e8me ann\u00e9e.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-4c1415ca auto-faq e-flex e-con-boxed e-con e-child\" data-id=\"4c1415ca\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-7c159763 elementor-widget elementor-widget-heading\" data-id=\"7c159763\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">FAQ<\/h2>\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-aedfc37f e-con-full e-flex e-con e-child\" data-id=\"aedfc37f\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-cbd232b0 elementor-widget elementor-widget-n-accordion\" data-id=\"cbd232b0\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;default_state&quot;:&quot;all_collapsed&quot;,&quot;max_items_expended&quot;:&quot;one&quot;,&quot;n_accordion_animation_duration&quot;:{&quot;unit&quot;:&quot;ms&quot;,&quot;size&quot;:400,&quot;sizes&quot;:[]}}\" data-widget_type=\"nested-accordion.default\">\n\t\t\t\t\t\t\t<div class=\"e-n-accordion\" aria-label=\"Accord\u00e9on. Ouvrez les liens \u00e0 l&#039;aide de la touche Entr\u00e9e ou de la barre d&#039;espace, fermez-les avec la touche \u00c9chap et naviguez \u00e0 l&#039;aide des touches fl\u00e9ch\u00e9es.\">\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-3410\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"1\" tabindex=\"0\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-3410\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Quelle est la diff\u00e9rence entre la capacit\u00e9 nominale, la capacit\u00e9 nominale de service et l'\u00e9nergie nominale d'un syst\u00e8me de stockage d'\u00e9nergie par batterie (BESS) ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3410\" class=\"elementor-element elementor-element-36b18e55 e-con-full e-flex e-con e-child\" data-id=\"36b18e55\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3410\" class=\"elementor-element elementor-element-282ea5c0 e-con-full e-flex e-con e-child\" data-id=\"282ea5c0\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ad8873f2 elementor-widget elementor-widget-heading\" data-id=\"ad8873f2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Conform\u00e9ment \u00e0 la norme CEI 62620 et aux conventions relatives aux batteries fixes : \u2022 La capacit\u00e9 nominale (Ah) est la valeur de charge de r\u00e9f\u00e9rence utilis\u00e9e pour d\u00e9terminer la taille d'une cellule ou d'une batterie. \u2022 La capacit\u00e9 nominale (Ah) est la capacit\u00e9 d\u00e9clar\u00e9e par le fabricant comme pouvant \u00eatre fournie dans des conditions sp\u00e9cifi\u00e9es de temp\u00e9rature, de taux de charge\/d\u00e9charge et de tension de coupure. \u2022 L\u2019\u00e9nergie nominale (Wh \/ kWh) est l\u2019\u00e9nergie de r\u00e9f\u00e9rence calcul\u00e9e \u00e0 partir de la tension et de la capacit\u00e9 nominales (par exemple : 260 \u00d7 3,2 V \u00d7 314 Ah = 261,248 kWh, indiqu\u00e9e comme 261,24 kWh sur la fiche technique Energon), tandis que l\u2019\u00e9nergie de d\u00e9charge mesur\u00e9e (Wh \/ kWh) correspond \u00e0 l\u2019\u00e9nergie r\u00e9elle int\u00e9gr\u00e9e dans le temps (\u222b V(t)I(t) dt) fournie au cours d\u2019un essai de d\u00e9charge normalis\u00e9.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-3411\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"2\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-3411\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Pourquoi la puissance active disponible est-elle inf\u00e9rieure \u00e0 la puissance nominale dans un syst\u00e8me de stockage d'\u00e9nergie par batterie (BESS) \u00e0 usage commercial ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3411\" class=\"elementor-element elementor-element-13748533 e-con-full e-flex e-con e-child\" data-id=\"13748533\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3411\" class=\"elementor-element elementor-element-11c3d712 e-con-full e-flex e-con e-child\" data-id=\"11c3d712\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-fab2de5b elementor-widget elementor-widget-heading\" data-id=\"fab2de5b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">L'\u00e9nergie CA utilisable au point de couplage est inf\u00e9rieure \u00e0 l'\u00e9nergie CC indiqu\u00e9e sur la plaque signal\u00e9tique en raison de trois facteurs : \u2022 Plage de fonctionnement SOC \/ DoD : le BMS fonctionne dans une plage d\u00e9finie de tension du syst\u00e8me et d\u2019\u00e9tat de charge (g\u00e9n\u00e9ralement entre 80 % et 90 % de DoD, par exemple de 676 V \u00e0 936 V sur Energon ou de 43,2 V \u00e0 57,6 V sur MEG-Solid-512314FL1) afin d\u2019\u00e9viter toute surcharge et d\u00e9charge excessive. \u2022 Pertes li\u00e9es \u00e0 la conversion de puissance et aux transformateurs : la conversion bidirectionnelle CC-CA dans le PCS et les transformateurs d\u2019isolation\/\u00e9l\u00e9vateurs entra\u00eene des pertes d\u2019\u00e9nergie. \u2022 Consommation parasite auxiliaire : les refroidisseurs \u00e0 liquide, les pompes, les ventilateurs d\u2019armoire, les contr\u00f4leurs BMS et les panneaux de protection incendie consomment de l\u2019\u00e9nergie auxiliaire pendant leur fonctionnement.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-3412\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"3\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-3412\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Le fait de d\u00e9charger un syst\u00e8me de stockage d'\u00e9nergie par batterie (BESS) de 314 Ah \u00e0 1P au lieu de 0,5P r\u00e9duit-il son \u00e9nergie disponible par cycle ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3412\" class=\"elementor-element elementor-element-4e30add3 e-con-full e-flex e-con e-child\" data-id=\"4e30add3\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3412\" class=\"elementor-element elementor-element-a5e595a7 e-con-full e-flex e-con e-child\" data-id=\"a5e595a7\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c664a473 elementor-widget elementor-widget-heading\" data-id=\"c664a473\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Oui. Une d\u00e9charge \u00e0 1P (d\u00e9bit de puissance constant sur 1 heure) fait environ doubler le courant continu par rapport \u00e0 un d\u00e9bit de 0,5P (d\u00e9bit sur 2 heures). Un courant plus \u00e9lev\u00e9 augmente les pertes r\u00e9sistives internes (I\u00b2 R_DC) et la polarisation de tension (I \u00d7 R_DC), ce qui fait que la tension aux bornes atteint plus t\u00f4t la limite inf\u00e9rieure de coupure du BMS au cours du cycle de d\u00e9charge. Les ing\u00e9nieurs charg\u00e9s de dimensionner une armoire 1C (telle que l\u2019ESSA0050B-0055 de 50 kW \/ 55,296 kWh) ou d\u2019\u00e9valuer la capacit\u00e9 de r\u00e9gulation de fr\u00e9quence en mode 1P doivent toujours demander la courbe de d\u00e9charge 1C \/ 1P sp\u00e9cifique au mod\u00e8le.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-3413\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"4\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-3413\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Qu'est-ce qui est pr\u00e9f\u00e9rable : une batterie au lithium ou une batterie plomb-acide de grande capacit\u00e9 pour une alimentation de secours solaire ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3413\" class=\"elementor-element elementor-element-fbfaef4f e-con-full e-flex e-con e-child\" data-id=\"fbfaef4f\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3413\" class=\"elementor-element elementor-element-4e2c07f5 e-con-full e-flex e-con e-child\" data-id=\"4e2c07f5\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-92994c6c elementor-widget elementor-widget-heading\" data-id=\"92994c6c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Les syst\u00e8mes de stockage au lithium (tels que le LiFePO\u2084 ou les batteries hybrides LFP \u00e0 l'\u00e9tat solide) offrent une densit\u00e9 \u00e9nerg\u00e9tique utile plus \u00e9lev\u00e9e et une dur\u00e9e de vie plus longue que les batteries plomb-acide \u00e0 d\u00e9charge profonde traditionnelles de m\u00eame capacit\u00e9 nominale en Ah. Les batteries au plomb-acide sont g\u00e9n\u00e9ralement limit\u00e9es \u00e0 environ 50 % de profondeur de d\u00e9charge (DoD) pour pr\u00e9server leur dur\u00e9e de vie (400 \u00e0 800 cycles) et subissent une r\u00e9duction de capacit\u00e9 plus marqu\u00e9e sous des charges \u00e0 taux C \u00e9lev\u00e9 en raison de l\u2019effet Peukert. Les unit\u00e9s au lithium modernes de 51,2 V et 314 Ah (MEG-Solid-512314FL1 \u00e0 16,07 kWh et MG 512314 \u00e0 16 076 Wh) offrent \u00e0 la fois une capacit\u00e9 en Ah \u00e9lev\u00e9e et une profondeur de d\u00e9charge (DoD) de 80 % lors de cycles quotidiens sur une dur\u00e9e de 6 000 \u00e0 8 000 cycles.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-3414\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"5\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-3414\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Est-ce que toutes les armoires et tous les conteneurs MegSolid C&amp;I utilisent la m\u00eame cellule de 314 Ah ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3414\" class=\"elementor-element elementor-element-3d3f0e95 e-con-full e-flex e-con e-child\" data-id=\"3d3f0e95\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3414\" class=\"elementor-element elementor-element-96f8bc45 e-con-full e-flex e-con e-child\" data-id=\"96f8bc45\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-619ff31a elementor-widget elementor-widget-heading\" data-id=\"619ff31a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Non. La capacit\u00e9 et la composition chimique des cellules d\u00e9pendent du mod\u00e8le exact du syst\u00e8me : \u2022 ESSA0100B-0215 (100 kW \/ 215,04 kWh) : utilise des cellules LFP standard de 280 Ah (avec, en option, des configurations de cellules \u00e0 semi-conducteurs sp\u00e9cifiques au projet, confirm\u00e9es par contrat). \u2022 Energon (125 kVA \/ 261,24 kWh) : utilise des cellules LFP standard de 314 Ah dans une cha\u00eene 1P260S \u00e0 refroidissement liquide. \u2022 5000INTL (2 700 kW \/ 5 015,9 kWh) : fait r\u00e9f\u00e9rence au code de type de batterie SHS180-314 sur sa fiche technique ; les acheteurs doivent v\u00e9rifier la fiche technique exacte des cellules et la configuration de l\u2019\u00e9lectrolyte attribu\u00e9es \u00e0 leur contrat de projet.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-3415\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"6\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-3415\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Comment les EPC peuvent-ils v\u00e9rifier les d\u00e9clarations d'un fournisseur de batteries concernant la capacit\u00e9 nominale de ses produits ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3415\" class=\"elementor-element elementor-element-05b170b5 e-con-full e-flex e-con e-child\" data-id=\"05b170b5\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3415\" class=\"elementor-element elementor-element-3774594f e-con-full e-flex e-con e-child\" data-id=\"3774594f\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-6a27c505 elementor-widget elementor-widget-heading\" data-id=\"6a27c505\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Demandez la fiche technique pr\u00e9cise du mod\u00e8le de cellule ou de bloc-batterie, la valeur en Ah d\u00e9clar\u00e9e, le courant de d\u00e9charge, la temp\u00e9rature d'essai, la tension de fin de d\u00e9charge et les r\u00e9sultats des tests FAT. V\u00e9rifiez s'il s'agit d'une valeur nominale de r\u00e9f\u00e9rence, d'une capacit\u00e9 nominale d\u00e9clar\u00e9e par le fabricant, d'un r\u00e9sultat de d\u00e9charge en courant continu mesur\u00e9 ou de l'\u00e9nergie en courant alternatif utilisable au point de raccordement sur site.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-3416\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"7\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-3416\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Pourquoi deux batteries ayant la m\u00eame capacit\u00e9 en Ah peuvent-elles fournir des quantit\u00e9s diff\u00e9rentes en kWh ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3416\" class=\"elementor-element elementor-element-112fbb84 e-con-full e-flex e-con e-child\" data-id=\"112fbb84\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3416\" class=\"elementor-element elementor-element-2086ea16 e-con-full e-flex e-con e-child\" data-id=\"2086ea16\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-1cc4ca5b elementor-widget elementor-widget-heading\" data-id=\"1cc4ca5b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Les amp\u00e8res-heures (Ah) indiquent la capacit\u00e9 de charge, tandis que l'\u00e9nergie d\u00e9pend \u00e9galement du profil de tension pendant la d\u00e9charge. Des tensions nominales diff\u00e9rentes, des seuils de coupure plus bas, des d\u00e9bits de d\u00e9charge, des temp\u00e9ratures et des r\u00e9sistances internes variables peuvent entra\u00eener des valeurs mesur\u00e9es en Wh diff\u00e9rentes pour des batteries pr\u00e9sentant la m\u00eame valeur nominale en Ah.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-3417\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"8\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-3417\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Comment calculer la puissance en CA utilisable pour une armoire Energon 261 ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3417\" class=\"elementor-element elementor-element-79faa5fb e-con-full e-flex e-con e-child\" data-id=\"79faa5fb\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3417\" class=\"elementor-element elementor-element-54a923da e-con-full e-flex e-con e-child\" data-id=\"54a923da\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-2f28ab34 elementor-widget elementor-widget-heading\" data-id=\"2f28ab34\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Commencez par la puissance nominale de 261,24 kWh, appliquez la plage de profondeur de d\u00e9charge (DoD) pr\u00e9vue et le rendement de sortie CA v\u00e9rifi\u00e9 s\u00e9par\u00e9ment, puis tenez compte des charges auxiliaires et de l'\u00e9tat de sant\u00e9 (SOH) en fin de vie. \u00c0 titre d\u2019exemple, un taux de d\u00e9charge (DoD) de 80 % et un rendement de sortie suppos\u00e9 de 90 % donnent 188,09 kWh ; il s\u2019agit d\u2019un exemple de dimensionnement, et non d\u2019une puissance de sortie garantie.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-3418\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"9\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-3418\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Quels sont les changements lorsque un syst\u00e8me de stockage d'\u00e9nergie par batterie (BESS) se d\u00e9charge \u00e0 1P au lieu de 0,5P ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3418\" class=\"elementor-element elementor-element-756a8851 e-con-full e-flex e-con e-child\" data-id=\"756a8851\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3418\" class=\"elementor-element elementor-element-34bde78c e-con-full e-flex e-con e-child\" data-id=\"34bde78c\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-b668207b elementor-widget elementor-widget-heading\" data-id=\"b668207b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">\u00c0 des d\u00e9bits de d\u00e9charge constants plus \u00e9lev\u00e9s, le courant continu et les pertes r\u00e9sistives augmentent ; la tension aux bornes peut atteindre le seuil de coupure du BMS plus t\u00f4t et l'\u00e9nergie fournie mesur\u00e9e peut diminuer. V\u00e9rifiez les courbes de d\u00e9charge exactes des cellules, les conditions de temp\u00e9rature et les limites de puissance de l'ensemble du syst\u00e8me avant de dimensionner le PCS ou de d\u00e9terminer l'autonomie pr\u00e9vue.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-3419\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"10\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-3419\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Quelles informations sont n\u00e9cessaires pour garantir l'autonomie d'une batterie en fin de vie ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3419\" class=\"elementor-element elementor-element-26a92fb1 e-con-full e-flex e-con e-child\" data-id=\"26a92fb1\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3419\" class=\"elementor-element elementor-element-627e9d4f e-con-full e-flex e-con e-child\" data-id=\"627e9d4f\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-2824340a elementor-widget elementor-widget-heading\" data-id=\"2824340a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Pr\u00e9cisez la charge CA nette et la dur\u00e9e requise, le taux de d\u00e9charge (DoD) de conception, les pertes de conversion et auxiliaires v\u00e9rifi\u00e9es, l'\u00e9tat de sant\u00e9 (SOH) minimal en fin de vie (EOL), le taux de charge (C-rate) maximal en fonctionnement, la plage de temp\u00e9rature et les conditions de coupure du BMS. Les indices de cyclage des mod\u00e8les SHS180 et SHS165 utilisent des seuils de SOH diff\u00e9rents (80 % et 70 %) et ne peuvent donc pas \u00eatre compar\u00e9s directement.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4e477980 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"4e477980\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Concevez votre projet gr\u00e2ce aux donn\u00e9es de capacit\u00e9 v\u00e9rifi\u00e9es de MegSolid<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d60f3637 auto-p elementor-widget elementor-widget-heading\" data-id=\"d60f3637\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Pour dimensionner un syst\u00e8me solaire commercial destin\u00e9 \u00e0 l'\u00e9cr\u00eatement des pics de consommation ou un syst\u00e8me solaire r\u00e9sidentiel de secours, il faut distinguer les valeurs nominales en Ah et en kWh indiqu\u00e9es sur les \u00e9tiquettes de l'\u00e9nergie CA r\u00e9ellement fournie et v\u00e9rifi\u00e9e. Que votre projet n\u00e9cessite une armoire ext\u00e9rieure ESSA d'une capacit\u00e9 comprise entre 55,296 kWh et 215,04 kWh, d'une armoire Energon LFP refroidie par liquide de 261,24 kWh, d'un conteneur industriel 5000INTL de 5 015,9 kWh ou d'une unit\u00e9 de stockage r\u00e9sidentielle de 51,2 V et 314 Ah, MegSolid fournit une documentation technique sp\u00e9cifique \u00e0 chaque mod\u00e8le ainsi qu'une assistance technique.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9b4ef820 auto-p elementor-widget elementor-widget-heading\" data-id=\"9b4ef820\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Contactez notre \u00e9quipe d'ing\u00e9nieurs pour examiner les fiches techniques des modules et des syst\u00e8mes et calculer la production en kWh adapt\u00e9e au profil de charge de votre site :<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2c9ae9c2 elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"2c9ae9c2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Pour les usines, les micro-r\u00e9seaux et la gestion des pics de consommation dans le secteur commercial (de 55 kWh \u00e0 plus de 5 MWh) : d\u00e9couvrez l'ensemble des caract\u00e9ristiques techniques et demandez une \u00e9valuation de capacit\u00e9 adapt\u00e9e \u00e0 votre projet sur notre <strong>Stockage d'\u00e9nergie \u00e0 usage commercial et industriel (C&amp;I)<\/strong> page.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Pour une alimentation solaire d'appoint \u00e0 domicile de 51,2 V et un mode de vie hors r\u00e9seau (de 16,07 kWh \u00e0 96,46 kWh) : comparez nos syst\u00e8mes de stockage domestiques hybrides \u00e0 semi-conducteurs et mobiles de 314 Ah sur notre <strong>Syst\u00e8mes de stockage d'\u00e9nergie \u00e0 usage r\u00e9sidentiel<\/strong> page.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-59a94326 elementor-tablet-align-center elementor-align-center auto-cta elementor-widget elementor-widget-button\" data-id=\"59a94326\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"#elementor-action%3Aaction%3Dpopup%3Aopen%26settings%3DeyJpZCI6Ijk0OCIsInRvZ2dsZSI6ZmFsc2V9\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Contactez-nous pour obtenir une \u00e9valuation pratique du dimensionnement de votre climatisation en kWh<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>D\u00e9couvrez les notions d'Ah nominal, de capacit\u00e9 nominale de la batterie et de kWh CA utilisables gr\u00e2ce aux exemples d'ing\u00e9nierie portant sur les syst\u00e8mes MegSolid 51,2 V, les armoires ESSA de 215,04 kWh et les syst\u00e8mes Energon de 261,24 kWh.<\/p>","protected":false},"author":4,"featured_media":7946,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"_joinchat":[],"footnotes":""},"categories":[27,1,713],"tags":[930,931,932,321,469,184,36,928,929,238],"class_list":["post-7950","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-news","category-bess","category-bess-procurement-economics","tag-battery-capacity-ah","tag-battery-nameplate-kwh","tag-battery-state-of-health","tag-bess-sizing","tag-energon-261","tag-essa0100b-0215","tag-MegSolid","tag-nominal-capacity","tag-rated-capacity","tag-usable-ac-energy"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/posts\/7950","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/comments?post=7950"}],"version-history":[{"count":3,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/posts\/7950\/revisions"}],"predecessor-version":[{"id":7953,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/posts\/7950\/revisions\/7953"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/media\/7946"}],"wp:attachment":[{"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/media?parent=7950"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/categories?post=7950"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/tags?post=7950"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}