{"id":7977,"date":"2026-11-05T13:47:50","date_gmt":"2026-11-05T05:47:50","guid":{"rendered":"https:\/\/www.solidess.com\/?p=7977"},"modified":"2026-11-05T13:47:50","modified_gmt":"2026-11-05T05:47:50","slug":"guide-sur-la-profondeur-de-decharge-des-batteries-dod","status":"publish","type":"post","link":"https:\/\/www.solidess.com\/fr\/depth-of-discharge-dod-battery-guide\/","title":{"rendered":"Guide sur la profondeur de d\u00e9charge (DoD) et les batteries \u00e0 d\u00e9charge profonde : dur\u00e9e de vie, protection par le BMS et \u00e9nergie utilisable dans les syst\u00e8mes de stockage d'\u00e9nergie par batterie au lithium (BESS)"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"7977\" class=\"elementor elementor-7977\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-bf4793c e-con-full auto-article-root e-flex e-con e-parent\" data-id=\"bf4793c\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-80cffa60 auto-p elementor-widget elementor-widget-heading\" data-id=\"80cffa60\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Lors du dimensionnement ou de l'exploitation d'une batterie fixe \u00e0 d\u00e9charge profonde, la profondeur de d\u00e9charge (DoD) indique la part de la capacit\u00e9 de r\u00e9f\u00e9rence ou de l'\u00e9nergie de la batterie qui est effectivement d\u00e9charg\u00e9e au cours d'un cycle. En termes techniques simples : DoD (%) = \u00e9nergie d\u00e9charg\u00e9e \u00f7 capacit\u00e9 \u00e9nerg\u00e9tique de r\u00e9f\u00e9rence \u00d7 100 %. Ce param\u00e8tre est essentiel, car la dur\u00e9e de vie, l\u2019\u00e9nergie utilisable, la dur\u00e9e d\u2019autonomie et le retour sur investissement s\u2019effondrent lorsque les acheteurs comparent les kWh nominaux sans v\u00e9rifier la base d\u2019essai approuv\u00e9e pour la DoD.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-572d7bbd auto-p elementor-widget elementor-widget-heading\" data-id=\"572d7bbd\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Dans l'ensemble du portefeuille publi\u00e9 par MegSolid, le <strong><a href=\"https:\/\/www.solidess.com\/fr\/product\/batterie-de-stockage-denergie-solide-megsold\/\" target=\"_blank\" style=\"color:#61ce70\">MEG-Solid-512314FL1<\/a><\/strong> La batterie hybride \u00e0 semi-conducteurs destin\u00e9e \u00e0 un usage r\u00e9sidentiel pr\u00e9sente les caract\u00e9ristiques suivantes : 51,2 V \/ 314 Ah \/ 16,07 kWh et 8 000 cycles \u00e0 80 % de profondeur de d\u00e9charge (DoD), la <strong><a href=\"https:\/\/www.solidess.com\/fr\/product\/bloc-batterie-au-lithium-amovible\/\" target=\"_blank\" style=\"color:#61ce70\">MG 512314<\/a><\/strong> L'unit\u00e9 mobile de 51,2 V \/ 314 Ah \/ 16,076 kWh est certifi\u00e9e pour \u2265 6 000 cycles \u00e0 25 \u00b0C et 80 % de capacit\u00e9 r\u00e9siduelle, et la <strong><a href=\"https:\/\/www.solidess.com\/fr\/product\/systeme-de-stockage-denergie-en-armoire-exterieure\/\" target=\"_blank\" style=\"color:#61ce70\">ESSA0100B-0215<\/a><\/strong> L'armoire C&amp;I pour usage ext\u00e9rieur a une puissance nominale de 100 kW \/ 215,04 kWh et une dur\u00e9e de vie de \u2265 5 000 cycles. Si vous examinez <strong><a href=\"https:\/\/www.solidess.com\/fr\/piles\/stockage-denergie-residentiel\/\" target=\"_blank\" style=\"color:#61ce70\">Syst\u00e8mes de stockage d'\u00e9nergie \u00e0 usage r\u00e9sidentiel<\/a><\/strong>, <strong><a href=\"https:\/\/www.solidess.com\/fr\/piles\/stockage-denergie-ci\/\" target=\"_blank\" style=\"color:#61ce70\">Syst\u00e8mes de stockage d'\u00e9nergie C&amp;I<\/a><\/strong> ou <strong><a href=\"https:\/\/www.solidess.com\/fr\/systemes-de-stockage-denergie-a-letat-solide\/\" target=\"_blank\" style=\"color:#61ce70\">Syst\u00e8mes de stockage d'\u00e9nergie \u00e0 l'\u00e9tat solide<\/a><\/strong>, ce guide fait la distinction entre un fonctionnement courant en cycle profond et une d\u00e9charge excessive dangereuse en dessous des limites de coupure.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-407047e5 auto-image elementor-widget elementor-widget-image\" data-id=\"407047e5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"1536\" height=\"864\" src=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/depth-of-discharge-key-points-overview-1536x864.webp\" class=\"attachment-1536x1536 size-1536x1536 wp-image-7974\" alt=\"Infographie sur la profondeur de d\u00e9charge expliquant la signification de la DoD, la DoD combin\u00e9e au SoC, la conception pour cycles profonds, les limites des batteries au plomb, et pourquoi un SoC affich\u00e9 \u00e0 0 % ne signifie pas n\u00e9cessairement que la batterie est endommag\u00e9e\" srcset=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/depth-of-discharge-key-points-overview-1536x864.webp 1536w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/depth-of-discharge-key-points-overview-300x169.webp 300w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/depth-of-discharge-key-points-overview-1024x576.webp 1024w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/depth-of-discharge-key-points-overview-768x432.webp 768w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/depth-of-discharge-key-points-overview-18x10.webp 18w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/depth-of-discharge-key-points-overview-600x338.webp 600w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/depth-of-discharge-key-points-overview.webp 2048w\" sizes=\"(max-width: 1536px) 100vw, 1536px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ec4c28fa auto-h2 elementor-widget elementor-widget-heading\" data-id=\"ec4c28fa\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Qu'est-ce qu'une batterie \u00e0 d\u00e9charge profonde ? Explications sur la d\u00e9charge profonde (DoD) et l'\u00e9tat de charge (SoC)<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a0068cd1 auto-p elementor-widget elementor-widget-heading\" data-id=\"a0068cd1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Lorsque les ing\u00e9nieurs recherchent la d\u00e9finition d'une \u00ab batterie \u00e0 d\u00e9charge profonde \u00bb, deux significations diff\u00e9rentes apparaissent. Confondre ces deux significations conduit \u00e0 des sp\u00e9cifications erron\u00e9es, \u00e0 des comparaisons de garantie inexactes et \u00e0 des r\u00e9glages de fonctionnement inadapt\u00e9s.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2044c962 auto-h3 elementor-widget elementor-widget-heading\" data-id=\"2044c962\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Deux significations techniques de l'expression \u201c d\u00e9charge profonde \u201d<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-94951945 elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"94951945\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>1. Capacit\u00e9 de conception pour les cycles de d\u00e9charge profonde :<\/strong> Dans le cadre de l'autoconsommation solaire, de l'alimentation de secours et de la r\u00e9duction des pics de consommation, une batterie \u00e0 d\u00e9charge profonde est une batterie con\u00e7ue pour effectuer des cycles sur une large plage d'utilisation, par exemple jusqu'\u00e0 80 % de profondeur de d\u00e9charge (DoD), sur plusieurs milliers de cycles.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>2. D\u00e9charge excessive abusive inf\u00e9rieure \u00e0 la limite inf\u00e9rieure autoris\u00e9e :<\/strong> Dans le cadre de l'analyse des d\u00e9faillances, on entend par \u00ab d\u00e9charge profonde \u00bb d'une batterie le fait de faire descendre la tension des cellules en dessous de la tension de coupure autoris\u00e9e par le fabricant, par exemple en dessous de la tension de coupure de 43,2 V indiqu\u00e9e pour le mod\u00e8le MEG-Solid-512314FL1 ou en dessous de la limite inf\u00e9rieure de fonctionnement de 40,0 V indiqu\u00e9e pour le mod\u00e8le MG 512314.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-27dcb55a auto-h3 elementor-widget elementor-widget-heading\" data-id=\"27dcb55a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Formule de base : profondeur de d\u00e9charge (DoD) et \u00e9tat de charge (SoC)<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-45737f37 auto-p elementor-widget elementor-widget-heading\" data-id=\"45737f37\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Sur une base \u00e9nerg\u00e9tique constante, le DoD (%) est calcul\u00e9 comme suit : \u00e9nergie d\u00e9charg\u00e9e \u00f7 capacit\u00e9 \u00e9nerg\u00e9tique de r\u00e9f\u00e9rence \u00d7 100 %. Selon la m\u00eame r\u00e9f\u00e9rence \u00e9talonn\u00e9e, la relation id\u00e9ale est la suivante : DoD (%) + SoC (%) = 100 %.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-84a2e253 elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"84a2e253\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>Exemple illustratif :<\/strong> Si une batterie dont l'\u00e9nergie de r\u00e9f\u00e9rence en courant continu est de 10,24 kWh fournit 9,20 kWh sur la m\u00eame base en courant continu, le taux de d\u00e9charge (DoD) est \u00e9gal \u00e0 9,20 \u00f7 10,24 \u00d7 100 % = 89,84 %, soit environ 90 % de DoD.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>N'utilisez qu'une seule base de capacit\u00e9 :<\/strong> Ne divisez jamais directement la puissance mesur\u00e9e en courant alternatif par la puissance nominale en courant continu indiqu\u00e9e sur la plaque signal\u00e9tique sans tenir compte de l'onduleur ou <strong><a href=\"https:\/\/www.solidess.com\/fr\/piles\/onduleur-de-stockage-denergie\/\" target=\"_blank\" style=\"color:#61ce70\">Pertes li\u00e9es \u00e0 la conversion du PCS<\/a><\/strong>, les chutes de tension et les charges auxiliaires.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>Le SoC affich\u00e9 est une estimation :<\/strong> Le SoC du BMS n'est pas une identit\u00e9 purement physique ; il s'agit d'une estimation algorithmique fond\u00e9e sur le comptage coulombique, la consultation des valeurs de tension, la temp\u00e9rature et l'\u00e9talonnage.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-11c2c910 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"11c2c910\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Comment le niveau de d\u00e9charge d'une batterie influe sur sa dur\u00e9e de vie en cycles et son rendement \u00e9nerg\u00e9tique global<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d0cbda45 auto-p elementor-widget elementor-widget-heading\" data-id=\"d0cbda45\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Lorsque les acheteurs comparent les offres de batteries en se basant uniquement sur le co\u00fbt initial en dollars par kWh, ils n\u00e9gligent g\u00e9n\u00e9ralement le chiffre qui d\u00e9termine r\u00e9ellement la rentabilit\u00e9 du stockage : la quantit\u00e9 d'\u00e9nergie que le syst\u00e8me peut fournir pendant toute la dur\u00e9e de d\u00e9charge (DoD) autoris\u00e9e avant d'atteindre l'\u00e9tat de fin de vie sp\u00e9cifi\u00e9.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7d89b776 auto-h3 elementor-widget elementor-widget-heading\" data-id=\"7d89b776\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Formule du d\u00e9bit sur la dur\u00e9e de vie et limites de comparabilit\u00e9<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f8626ef5 auto-p elementor-widget elementor-widget-heading\" data-id=\"f8626ef5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Pour un mod\u00e8le de batterie donn\u00e9, test\u00e9 \u00e0 un niveau de d\u00e9charge (DoD) sp\u00e9cifi\u00e9 et avec un nombre de cycles nominal, le d\u00e9bit \u00e9nerg\u00e9tique th\u00e9orique sur toute la dur\u00e9e de vie peut s'exprimer comme suit : E_dur\u00e9e_de_vie = N_cycles \u00d7 E_par_cycle.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4b5ce1b9 elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"4b5ce1b9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>Il n'existe pas de coefficient multiplicateur universel valable pour toutes les compositions chimiques ou tous les mod\u00e8les :<\/strong> Il est impossible de convertir en toute s\u00e9curit\u00e9 8 000 cycles \u00e0 80 % de profondeur de d\u00e9charge (DoD) en un nombre garanti \u00e0 90 % ou 95 % de DoD sans disposer de courbes d'essai sp\u00e9cifiques au mod\u00e8le.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>Ne pas extrapoler au-del\u00e0 des cotes publi\u00e9es :<\/strong> Le mod\u00e8le MEG-Solid-512314FL1 est officiellement certifi\u00e9 pour 8 000 cycles \u00e0 80 % de profondeur de d\u00e9charge (DoD). Cela n'autorise toutefois pas \u00e0 affirmer qu'il offre entre 8 000 et plus de 10 000 cycles \u00e0 95 % de profondeur de d\u00e9charge (DoD) ou plus de 11 000 cycles en cas de cycles peu profonds.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>La variation de la capacit\u00e9 influe sur l'\u00e9nergie par cycle :<\/strong> Un simple calcul de multiplication permet d'obtenir une estimation maximale de la dur\u00e9e de vie initiale. \u00c0 mesure que la dur\u00e9e de vie initiale (SOH) diminue pour atteindre le seuil de fin de vie, l'\u00e9nergie fournie par cycle diminue \u00e9galement.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>Les batteries au plomb-acide font l'objet de pratiques diff\u00e9rentes tout au long de leur cycle de vie :<\/strong> La recommandation d'une profondeur de d\u00e9charge (DoD) de 50 % pour les batteries au plomb-acide rel\u00e8ve d'une strat\u00e9gie de durabilit\u00e9, et non d'un seuil magique de destruction. Les batteries au plomb-acide \u00e0 d\u00e9charge profonde peuvent \u00eatre d\u00e9charg\u00e9es davantage, mais leur dur\u00e9e de vie diminue alors rapidement.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-fc921c8a auto-table elementor-widget elementor-widget-text-editor\" data-id=\"fc921c8a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"cea-table-wrap\"><table><thead><tr><th>Mod\u00e8le MegSolid<\/th><th>Tension, capacit\u00e9 et \u00e9nergie confirm\u00e9es<\/th><th>Sp\u00e9cifications techniques confirm\u00e9es concernant les cellules et la gestion thermique<\/th><th>Sp\u00e9cifications publi\u00e9es concernant la dur\u00e9e de vie et le taux de d\u00e9charge (DoD)<\/th><th>Note relative au d\u00e9bit et au dimensionnement techniques<\/th><\/tr><\/thead><tbody><tr><td>MEG-Solid-512314FL1 (usage r\u00e9sidentiel)<\/td><td>51,2 V \/ 314 Ah \/ 16,07 kWh (plage de fonctionnement : 43,2\u201357,6 V ; coupure de d\u00e9charge \u00e0 43,2 V)<\/td><td>LiFePO4 hybride \u00e0 l'\u00e9tat solide, 314 Ah<\/td><td>8 000 cycles \u00e0 80 % de profondeur de d\u00e9charge (DoD)<\/td><td>\u00c0 80 % de profondeur de d\u00e9charge (DoD), 12,856 kWh CC en charge initiale (BOL) par cycle ; produit maximal en charge initiale (BOL) = 102,85 MWh CC avant la d\u00e9gradation de l'\u00e9tat de sant\u00e9 (SOH) et les pertes de l'onduleur<\/td><\/tr><tr><td>MG 512314 (Logement mobile)<\/td><td>51,2 V \/ 314 Ah \/ 16,076 kWh (plage de fonctionnement : 40,0\u201358,4 V)<\/td><td>Batterie de 314 Ah : la page produit indique une capacit\u00e9 \u2265 314 Ah \u00e0 0,2 C<\/td><td>\u2265 6 000 cycles \u00e0 25 \u00b0C, 80 % de la dur\u00e9e de vie utile (EOL)<\/td><td>V\u00e9rifier le pourcentage de DoD indiqu\u00e9 dans la documentation de contr\u00f4le avant de calculer le nombre de MWh sur la dur\u00e9e de vie<\/td><\/tr><tr><td>ESSA0100B-0215 (C&amp;I Armoire d'ext\u00e9rieur)<\/td><td>768 V, 100 kW CA, 215,04 kWh, 672\u2013850 V CC<\/td><td>280 Ah LFP, 0,5 C, refroidissement par air intelligent<\/td><td>\u2265 5 000 cycles<\/td><td>Composition chimique LFP standard de 280 Ah ; v\u00e9rifier les limites de profondeur de d\u00e9charge (DoD) et de fin de vie (EOL) conform\u00e9ment au contrat<\/td><\/tr><tr><td>Energon 261 (Armoire C&amp;I \u00e0 refroidissement liquide)<\/td><td>832 V, 125 kVA CA, 261,24 kWh, 676\u2013936 V CC<\/td><td>314 Ah LFP, refroidissement intelligent par liquide<\/td><td>V\u00e9rifier la dur\u00e9e de vie, la fen\u00eatre de d\u00e9charge (DoD) et la courbe d'\u00e9tat de sant\u00e9 (SOH) sp\u00e9cifiques au projet dans la documentation contr\u00f4l\u00e9e<\/td><td>V\u00e9rifier le facteur de puissance, les conditions d'essai et la marge de charge auxiliaire<\/td><\/tr><tr><td>5000INTL (conteneur polyvalent de 20 pieds)<\/td><td>1 331,2 V, 2 700 kW CA, 5 015,9 kWh, 1 123,2\u20131 497,6 V CC<\/td><td>Code produit SHS180-314 ; refroidissement liquide intelligent<\/td><td>V\u00e9rifier la dur\u00e9e de vie, le degr\u00e9 de d\u00e9charge (DoD) et la cat\u00e9gorie d'\u00e9lectrolyte au niveau de chaque conteneur \u00e0 l'aide d'une documentation contr\u00f4l\u00e9e<\/td><td>Ne d\u00e9duisez pas le type d'\u00e9lectrolyte uniquement \u00e0 partir du code de la cellule.<\/td><\/tr><\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-dc72735c auto-image elementor-widget elementor-widget-image\" data-id=\"dc72735c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"1536\" height=\"864\" src=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/lifetime-energy-throughput-80-percent-dod-8000-cycles-1536x864.webp\" class=\"attachment-1536x1536 size-1536x1536 wp-image-7975\" alt=\"Infographie sur le d\u00e9bit cumul\u00e9 sur toute la dur\u00e9e de vie indiquant une puissance nominale de 16,07 kilowattheures, une profondeur de d\u00e9charge (DoD) de 80 %, 8 000 cycles et un d\u00e9bit cumul\u00e9 en courant continu de 102,85 m\u00e9gawattheures\" srcset=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/lifetime-energy-throughput-80-percent-dod-8000-cycles-1536x864.webp 1536w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/lifetime-energy-throughput-80-percent-dod-8000-cycles-300x169.webp 300w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/lifetime-energy-throughput-80-percent-dod-8000-cycles-1024x576.webp 1024w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/lifetime-energy-throughput-80-percent-dod-8000-cycles-768x432.webp 768w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/lifetime-energy-throughput-80-percent-dod-8000-cycles-18x10.webp 18w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/lifetime-energy-throughput-80-percent-dod-8000-cycles-600x338.webp 600w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/lifetime-energy-throughput-80-percent-dod-8000-cycles.webp 2048w\" sizes=\"(max-width: 1536px) 100vw, 1536px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b86ce3f4 auto-h3 elementor-widget elementor-widget-heading\" data-id=\"b86ce3f4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Comment analyser les fiches techniques et les conditions de garantie des syst\u00e8mes de stockage d'\u00e9nergie par batterie (BESS) : comparaison entre les exigences du minist\u00e8re am\u00e9ricain de la D\u00e9fense (DoD) et la dur\u00e9e de vie utile<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9541a04d elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"9541a04d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>1. V\u00e9rifiez la vitesse d'essai et la temp\u00e9rature :<\/strong> La dur\u00e9e de vie en cycles n'est comparable que lorsque le taux de charge\/d\u00e9charge sous-jacent et la temp\u00e9rature ambiante sont tous deux clairement indiqu\u00e9s.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>2. V\u00e9rifiez le crit\u00e8re de fin de vie :<\/strong> V\u00e9rifiez si le comptage cyclique s'arr\u00eate \u00e0 80 %, 70 % ou 60 % de SOH. Un chiffre plus \u00e9lev\u00e9 associ\u00e9 \u00e0 une d\u00e9finition plus souple de la fin de vie (EOL) ne signifie pas que la batterie est de meilleure qualit\u00e9.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>3. V\u00e9rifiez la position de la fen\u00eatre PSoC :<\/strong> Deux profils peuvent pr\u00e9senter la m\u00eame plage de profondeur de gravure (DoD), mais des contraintes tr\u00e8s diff\u00e9rentes si l'un d'eux se situe pr\u00e8s du point d'inflexion sup\u00e9rieur de la tension.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>4. Distinguer les donn\u00e9es cellulaires des donn\u00e9es relatives \u00e0 l'ensemble du syst\u00e8me :<\/strong> Le r\u00e9sultat d'un test de cellule ne correspond pas \u00e0 la puissance nominale totale d'une armoire ou d'un conteneur, o\u00f9 les gradients thermiques, la dispersion des cellules et le rendement du syst\u00e8me PCS sont les principaux facteurs qui d\u00e9terminent la puissance CA utile.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1ecfb4ed elementor-tablet-align-center elementor-align-center auto-cta elementor-widget elementor-widget-button\" data-id=\"1ecfb4ed\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"#elementor-action%3Aaction%3Dpopup%3Aopen%26settings%3DeyJpZCI6Ijk0OCIsInRvZ2dsZSI6ZmFsc2V9\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Contactez-nous pour une analyse du DoD et du dimensionnement en fonction de la dur\u00e9e de vie<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-55846d43 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"55846d43\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Risques li\u00e9s \u00e0 une d\u00e9charge excessive : que se passe-t-il lors d'une d\u00e9charge profonde d'une batterie au-del\u00e0 des limites de coupure ?<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0f06d044 auto-p elementor-widget elementor-widget-heading\" data-id=\"0f06d044\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Le fait d'atteindre un niveau de charge (SoC) affich\u00e9 de 0 % au cours d'un cycle de d\u00e9charge normal ne signifie pas automatiquement que la batterie est endommag\u00e9e. En fonctionnement normal, l'onduleur et le BMS interrompent la d\u00e9charge \u00e0 la limite inf\u00e9rieure de fonctionnement autoris\u00e9e, tandis qu'une charge de protection subsiste dans les cellules. Une d\u00e9charge excessive dangereuse ne commence que lorsque le pack est pouss\u00e9 en dessous de son seuil minimum autoris\u00e9, souvent parce que des charges restent connect\u00e9es apr\u00e8s la coupure ou qu\u2019une batterie d\u00e9charg\u00e9e reste trop longtemps sans \u00eatre recharg\u00e9e.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-55872aae auto-h3 elementor-widget elementor-widget-heading\" data-id=\"55872aae\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">M\u00e9canisme \u00e9lectrochimique de la d\u00e9charge excessive grave<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-968a1979 elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"968a1979\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>Augmentation du potentiel de l'anode :<\/strong> Dans une cellule lithium-ion, l'\u00e9lectrode n\u00e9gative est d\u00e9pos\u00e9e sur une feuille de cuivre. En cas de d\u00e9charge excessive, le potentiel de l'\u00e9lectrode n\u00e9gative peut augmenter au point de pr\u00e9senter un risque de dissolution du cuivre.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>Il n'existe pas de tension de d\u00e9clenchement universelle unique :<\/strong> Il n'existe pas de valeur fixe par cellule qui marque syst\u00e9matiquement le d\u00e9but des dommages, quelle que soit la composition chimique ou la temp\u00e9rature. Le risque d\u00e9pend de la composition chimique de la cellule, de la temp\u00e9rature, de la dur\u00e9e et de l'intensit\u00e9 de la d\u00e9charge excessive.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>Risque li\u00e9 \u00e0 la recharge :<\/strong> Si le cuivre dissous se red\u00e9pose par la suite lors de la recharge, cela peut entra\u00eener un risque d'autod\u00e9charge, de perte de capacit\u00e9 ou de court-circuit interne. Une batterie ayant subi une d\u00e9charge excessive doit faire l'objet d'une \u00e9valuation par un professionnel et ne doit pas \u00eatre recharg\u00e9e de force.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5e781116 auto-h3 elementor-widget elementor-widget-heading\" data-id=\"5e781116\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Trois fonctions de protection \u00e0 v\u00e9rifier lors de la conception technique d'un syst\u00e8me de stockage d'\u00e9nergie par batterie (BESS)<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a5b0063d auto-p elementor-widget elementor-widget-heading\" data-id=\"a5b0063d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">\u00c9tant donn\u00e9 que les plages de tension de fonctionnement publi\u00e9es ne correspondent pas \u00e0 la logique de protection interne du mat\u00e9riel, les ing\u00e9nieurs doivent v\u00e9rifier s\u00e9par\u00e9ment les r\u00e9glages de r\u00e9serve de l'onduleur, la protection contre les sous-tensions du BMS et le protocole de reprise apr\u00e8s un d\u00e9faut de sous-tension grave.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6c16310a auto-table elementor-widget elementor-widget-text-editor\" data-id=\"6c16310a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"cea-table-wrap\"><table><thead><tr><th>Cat\u00e9gorie de fonction de protection<\/th><th>Objectif technique<\/th><th>Param\u00e8tres cl\u00e9s \u00e0 v\u00e9rifier conform\u00e9ment \u00e0 la documentation du mod\u00e8le<\/th><th>Protocole op\u00e9rationnel et de reprise des activit\u00e9s<\/th><\/tr><\/thead><tbody><tr><td>1. R\u00e9serve de SoC op\u00e9rationnelle du syst\u00e8me EMS \/ onduleur hybride<\/td><td>Emp\u00eache les d\u00e9charges quotidiennes courantes en courant alternatif tout en conservant une marge utile au-dessus de la limite inf\u00e9rieure de tension de la batterie<\/td><td>R\u00e9serve minimale de SoC programmable par l'utilisateur, r\u00e9glage du seuil de coupure en cas de sous-tension de l'onduleur et communication BMS via CAN ou RS485<\/td><td>L'onduleur interrompt l'alimentation de la charge CA au niveau de la r\u00e9serve configur\u00e9e, tout en laissant les circuits photovolta\u00efques et de charge disponibles pour un retour \u00e0 la normale.<\/td><\/tr><tr><td>2. Protection contre les sous-tensions du syst\u00e8me de gestion de batterie (BMS) au niveau du pack ou du rack<\/td><td>Coupure ou blocage de la d\u00e9charge si la tension du bloc ou de la cellule atteint le seuil de protection du BMS<\/td><td>Plage de tension de fonctionnement publi\u00e9e, ainsi que les sp\u00e9cifications relatives au d\u00e9clenchement et \u00e0 la reprise du BMS en cas de tension inf\u00e9rieure au seuil minimal (UVP)<\/td><td>Ne partez pas du principe que le r\u00e9veil est automatique ; v\u00e9rifiez la logique exacte de r\u00e9initialisation et de reprise du BMS dans le manuel sp\u00e9cifique au mod\u00e8le.<\/td><\/tr><tr><td>3. Verrouillage en cas de d\u00e9faut de sous-tension grave et mise en attente de diagnostic<\/td><td>Emp\u00eache toute recharge dangereuse si la tension des cellules est inf\u00e9rieure au seuil minimal de r\u00e9cup\u00e9ration autoris\u00e9 par le fabricant<\/td><td>Seuil de coupure totale au niveau de la cellule, courant de repos du BMS et taux d'autod\u00e9charge<\/td><td>N'essayez jamais de proc\u00e9der \u00e0 une charge forc\u00e9e ou \u00e0 un d\u00e9marrage \u00e0 l'aide de c\u00e2bles de d\u00e9marrage par vos propres moyens ; d\u00e9branchez toutes les charges et faites inspecter le bloc-batterie par MegSolid ou par un technicien qualifi\u00e9.<\/td><\/tr><\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e20feaa0 auto-image elementor-widget elementor-widget-image\" data-id=\"e20feaa0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"1536\" height=\"864\" src=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/three-layers-low-voltage-protection-bms-uvp-1536x864.webp\" class=\"attachment-1536x1536 size-1536x1536 wp-image-7976\" alt=\"Infographie sur la protection contre les basses tensions illustrant la r\u00e9serve de l&#039;onduleur, la protection contre les sous-tensions du BMS et le verrouillage en cas de d\u00e9faut pour les syst\u00e8mes de batteries au lithium\" srcset=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/three-layers-low-voltage-protection-bms-uvp-1536x864.webp 1536w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/three-layers-low-voltage-protection-bms-uvp-300x169.webp 300w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/three-layers-low-voltage-protection-bms-uvp-1024x576.webp 1024w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/three-layers-low-voltage-protection-bms-uvp-768x432.webp 768w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/three-layers-low-voltage-protection-bms-uvp-18x10.webp 18w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/three-layers-low-voltage-protection-bms-uvp-600x338.webp 600w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/three-layers-low-voltage-protection-bms-uvp.webp 2048w\" sizes=\"(max-width: 1536px) 100vw, 1536px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-80705cbf auto-h2 elementor-widget elementor-widget-heading\" data-id=\"80705cbf\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Exemples de sc\u00e9narios pour la configuration des r\u00e9serves op\u00e9rationnelles du minist\u00e8re de la D\u00e9fense et du SoC<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9dfcc374 elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"9dfcc374\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>Autoconsommation solaire raccord\u00e9e au r\u00e9seau et arbitrage tarifaire en fonction des heures de consommation :<\/strong> Une r\u00e9serve quotidienne de 20 % de SoC, \u00e9quivalente \u00e0 une profondeur de d\u00e9charge (DoD) op\u00e9rationnelle de 80 %, correspond aux crit\u00e8res de test publi\u00e9s, \u00e0 savoir 8 000 cycles \u00e0 une DoD de 80 %, selon <strong><a href=\"https:\/\/www.solidess.com\/fr\/product\/batterie-de-stockage-denergie-solide-megsold\/\" target=\"_blank\" style=\"color:#61ce70\">MEG-Solid-512314FL1<\/a><\/strong> tout en conservant une marge sup\u00e9rieure au seuil de coupure de d\u00e9charge de 43,2 V.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>Pannes fr\u00e9quentes du r\u00e9seau \u00e9lectrique et priorit\u00e9s en mati\u00e8re d'alimentation de secours :<\/strong> Dans les r\u00e9gions o\u00f9 les coupures de courant sont fr\u00e9quentes, les op\u00e9rateurs peuvent interrompre le cycle \u00e9conomique quotidien \u00e0 un niveau de charge de 30 % \u00e0 40 %, afin que la plage inf\u00e9rieure reste r\u00e9serv\u00e9e aux charges d'urgence associ\u00e9es \u00e0 un syst\u00e8me compatible <strong><a href=\"https:\/\/www.solidess.com\/fr\/piles\/onduleur-de-stockage-denergie\/\" target=\"_blank\" style=\"color:#61ce70\">onduleur hybride<\/a><\/strong>.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>Syst\u00e8me solaire hors r\u00e9seau associ\u00e9 \u00e0 un groupe \u00e9lectrog\u00e8ne de secours :<\/strong> Programmez le d\u00e9clenchement du d\u00e9marrage automatique du groupe \u00e9lectrog\u00e8ne \u00e0 un niveau sup\u00e9rieur au seuil de coupure de l'onduleur en cas de batterie faible, afin que le groupe \u00e9lectrog\u00e8ne puisse d\u00e9marrer, se stabiliser et prendre en charge la charge de recharge avant que la batterie n'atteigne sa limite inf\u00e9rieure de d\u00e9charge.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-343e1634 auto-p elementor-widget elementor-widget-heading\" data-id=\"343e1634\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Pour les \u00e9quipes de projet qui comparent des produits, la bonne question n\u2019est pas \u201c Quelle est l\u2019autonomie maximale de la batterie ? \u201d. La v\u00e9ritable question est : \u201c \u00c0 quel degr\u00e9 de d\u00e9charge (DoD), dans quelles conditions d\u2019essai, jusqu\u2019\u00e0 quelle limite de fin de vie, et avec quelle logique de protection ? \u201d. C\u2019est ainsi que l\u2019on pr\u00e9serve la rentabilit\u00e9 sur l\u2019ensemble du cycle de vie, plut\u00f4t que de se contenter d\u2019un chiffre accrocheur, rassurant mais d\u00e9nu\u00e9 de sens.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-979cf3fa auto-p elementor-widget elementor-widget-heading\" data-id=\"979cf3fa\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Si votre installation n\u00e9cessite une coordination v\u00e9rifi\u00e9e entre la batterie et l'onduleur, comparez les <strong><a href=\"https:\/\/www.solidess.com\/fr\/product\/batterie-de-stockage-denergie-solide-megsold\/\" target=\"_blank\" style=\"color:#61ce70\">MEG-Solid-512314FL1<\/a><\/strong>, <strong><a href=\"https:\/\/www.solidess.com\/fr\/product\/bloc-batterie-au-lithium-amovible\/\" target=\"_blank\" style=\"color:#61ce70\">MG 512314<\/a><\/strong>, <strong><a href=\"https:\/\/www.solidess.com\/fr\/product\/systeme-de-stockage-denergie-en-armoire-exterieure\/\" target=\"_blank\" style=\"color:#61ce70\">gamme d'armoires ext\u00e9rieures ESSA<\/a><\/strong>, <strong><a href=\"https:\/\/www.solidess.com\/fr\/product\/stockage-denergie-solide-liquide-megasolide\/\" target=\"_blank\" style=\"color:#61ce70\">ESS Energon 261 \u00e0 refroidissement par liquide<\/a><\/strong> et <strong><a href=\"https:\/\/www.solidess.com\/fr\/product\/systeme-de-stockage-denergie-conteneurise-megasolid-5000intl\/\" target=\"_blank\" style=\"color:#61ce70\">5 000 conteneurs de stockage INTL<\/a><\/strong> en les comparant les uns aux autres sur la base des m\u00eames sp\u00e9cifications techniques avant de signer un contrat d'achat.<\/p>\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-90c21b40 auto-faq e-flex e-con-boxed e-con e-child\" data-id=\"90c21b40\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-7d5cadd0 elementor-widget elementor-widget-heading\" data-id=\"7d5cadd0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">FAQ<\/h2>\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-92224b23 e-con-full e-flex e-con e-child\" data-id=\"92224b23\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-fd1ccaf5 elementor-widget elementor-widget-n-accordion\" data-id=\"fd1ccaf5\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;default_state&quot;:&quot;all_collapsed&quot;,&quot;max_items_expended&quot;:&quot;one&quot;,&quot;n_accordion_animation_duration&quot;:{&quot;unit&quot;:&quot;ms&quot;,&quot;size&quot;:400,&quot;sizes&quot;:[]}}\" data-widget_type=\"nested-accordion.default\">\n\t\t\t\t\t\t\t<div class=\"e-n-accordion\" aria-label=\"Accord\u00e9on. Ouvrez les liens \u00e0 l&#039;aide de la touche Entr\u00e9e ou de la barre d&#039;espace, fermez-les avec la touche \u00c9chap et naviguez \u00e0 l&#039;aide des touches fl\u00e9ch\u00e9es.\">\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-4240\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"1\" tabindex=\"0\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-4240\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Que signifie \u00ab profondeur de d\u00e9charge \u00bb (DoD) dans un syst\u00e8me de stockage d'\u00e9nergie par batterie ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-4240\" class=\"elementor-element elementor-element-ea880300 e-con-full e-flex e-con e-child\" data-id=\"ea880300\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-4240\" class=\"elementor-element elementor-element-90cb0b29 e-con-full e-flex e-con e-child\" data-id=\"90cb0b29\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c77b6284 elementor-widget elementor-widget-heading\" data-id=\"c77b6284\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">La profondeur de d\u00e9charge correspond au pourcentage de la capacit\u00e9 de r\u00e9f\u00e9rence ou de l'\u00e9nergie d'une batterie qui a \u00e9t\u00e9 d\u00e9charg\u00e9e au cours d'un cycle. Si une batterie de r\u00e9f\u00e9rence de 10,24 kWh fournit 9,20 kWh sur la m\u00eame base en courant continu, la profondeur de d\u00e9charge est d'environ 90 %. Les acheteurs doivent v\u00e9rifier si la base de r\u00e9f\u00e9rence est l'\u00e9nergie en courant continu (CC), l'\u00e9nergie en courant alternatif (CA) ou les Ah, et s'assurer que le num\u00e9rateur et le d\u00e9nominateur sont exprim\u00e9s sur la m\u00eame base.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-4241\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"2\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-4241\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Un DoD de 80 % correspond-il \u00e0 un SoC de 20 % ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-4241\" class=\"elementor-element elementor-element-00f0c5a1 e-con-full e-flex e-con e-child\" data-id=\"00f0c5a1\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-4241\" class=\"elementor-element elementor-element-547d94b5 e-con-full e-flex e-con e-child\" data-id=\"547d94b5\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-6e937dd0 elementor-widget elementor-widget-heading\" data-id=\"6e937dd0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Si l'on se base sur la m\u00eame r\u00e9f\u00e9rence calibr\u00e9e, oui : la somme du DoD et du SoC est \u00e9gale \u00e0 100 %. Dans la pratique, le SoC affich\u00e9 est une estimation du BMS influenc\u00e9e par le comptage de coulombs, la consultation des valeurs de tension, la temp\u00e9rature et l'\u00e9talonnage ; il ne faut donc pas le consid\u00e9rer comme une identit\u00e9 physique parfaite \u00e0 chaque instant.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-4242\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"3\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-4242\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Un niveau de charge (SoC) affich\u00e9 \u00e0 0 % signifie-t-il que la batterie a \u00e9t\u00e9 endommag\u00e9e par une d\u00e9charge profonde ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-4242\" class=\"elementor-element elementor-element-3020e5c4 e-con-full e-flex e-con e-child\" data-id=\"3020e5c4\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-4242\" class=\"elementor-element elementor-element-93df469b e-con-full e-flex e-con e-child\" data-id=\"93df469b\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c3ad56f3 elementor-widget elementor-widget-heading\" data-id=\"c3ad56f3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Non. Dans un syst\u00e8me correctement configur\u00e9, l'onduleur ou le BMS interrompt la d\u00e9charge \u00e0 la limite inf\u00e9rieure d'utilisation autoris\u00e9e, alors qu'il reste encore une charge de protection dans les cellules. Le risque de dommages augmente lorsque le pack reste d\u00e9charg\u00e9 pendant une longue p\u00e9riode ou est pouss\u00e9 en dessous de la tension de coupure minimale indiqu\u00e9e par le fabricant.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-4243\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"4\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-4243\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Quelles sont la dur\u00e9e de vie et le taux de d\u00e9charge (DoD) officiellement indiqu\u00e9s pour le MEG-Solid-512314FL1 ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-4243\" class=\"elementor-element elementor-element-8a183c0e e-con-full e-flex e-con e-child\" data-id=\"8a183c0e\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-4243\" class=\"elementor-element elementor-element-22b2073e e-con-full e-flex e-con e-child\" data-id=\"22b2073e\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-b3f69684 elementor-widget elementor-widget-heading\" data-id=\"b3f69684\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">La fiche technique publi\u00e9e du mod\u00e8le MEG-Solid-512314FL1 indique les caract\u00e9ristiques suivantes : 51,2 V, 314 Ah, 16,07 kWh, une plage de fonctionnement de 43,2 V \u00e0 57,6 V, une coupure de d\u00e9charge \u00e0 43,2 V et 8 000 cycles \u00e0 80 % de profondeur de d\u00e9charge (DoD). Ces chiffres s\u2019appliquent uniquement \u00e0 ce mod\u00e8le et aux conditions d\u2019essai indiqu\u00e9es.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-4244\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"5\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-4244\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Quel est le d\u00e9bit \u00e9nerg\u00e9tique th\u00e9orique sur toute la dur\u00e9e de vie du MEG-Solid-512314FL1 \u00e0 un taux de d\u00e9charge (DoD) de 80 % ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-4244\" class=\"elementor-element elementor-element-77e573b8 e-con-full e-flex e-con e-child\" data-id=\"77e573b8\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-4244\" class=\"elementor-element elementor-element-44a6c036 e-con-full e-flex e-con e-child\" data-id=\"44a6c036\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-4ad659b2 elementor-widget elementor-widget-heading\" data-id=\"4ad659b2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">\u00c0 80 % de profondeur de d\u00e9charge (DoD), un cycle correspond \u00e0 12,856 kWh d'\u00e9nergie en courant continu (CC) en d\u00e9but de vie. En multipliant ce chiffre par 8 000 cycles, on obtient un d\u00e9bit th\u00e9orique maximal sur la dur\u00e9e de vie de 102,85 MWh en courant continu (CC), avant la d\u00e9gradation de l'\u00e9tat de sant\u00e9 (SOH), les pertes de conversion de l'onduleur et la consommation des syst\u00e8mes auxiliaires.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-4245\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"6\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-4245\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Les acheteurs peuvent-ils extrapoler les 8 000 cycles \u00e0 80 % de profondeur de d\u00e9charge (DoD) pour en d\u00e9duire des performances garanties \u00e0 90 % ou 95 % de profondeur de d\u00e9charge (DoD) ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-4245\" class=\"elementor-element elementor-element-876de4f8 e-con-full e-flex e-con e-child\" data-id=\"876de4f8\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-4245\" class=\"elementor-element elementor-element-bb71d938 e-con-full e-flex e-con e-child\" data-id=\"bb71d938\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-74508174 elementor-widget elementor-widget-heading\" data-id=\"74508174\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Non. Il n'existe pas de coefficient de conversion universel permettant de convertir en toute s\u00e9curit\u00e9 la dur\u00e9e de vie cyclique entre diff\u00e9rentes plages de profondeur de d\u00e9charge (DoD) pour des compositions chimiques et des produits diff\u00e9rents. Toute affirmation concernant un fonctionnement \u00e0 une profondeur de d\u00e9charge (DoD) plus \u00e9lev\u00e9e ou plus faible doit s'appuyer sur des donn\u00e9es d'essai sp\u00e9cifiques au mod\u00e8le et sur les conditions de garantie, et non sur des extrapolations commerciales.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-4246\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"7\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-4246\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> En quoi le mod\u00e8le MG 512314 diff\u00e8re-t-il du mod\u00e8le MEG-Solid-512314FL1 ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-4246\" class=\"elementor-element elementor-element-c2db5a5d e-con-full e-flex e-con e-child\" data-id=\"c2db5a5d\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-4246\" class=\"elementor-element elementor-element-cb7dea58 e-con-full e-flex e-con e-child\" data-id=\"cb7dea58\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ee340046 elementor-widget elementor-widget-heading\" data-id=\"ee340046\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Ces deux produits appartiennent \u00e0 la cat\u00e9gorie 51,2 V 314 Ah, mais leurs plages de fonctionnement et leurs caract\u00e9ristiques de cycles indiqu\u00e9es diff\u00e8rent. Le mod\u00e8le MEG-Solid-512314FL1 indique 16,07 kWh, une tension comprise entre 43,2 V et 57,6 V, et 8 000 cycles \u00e0 80 % de profondeur de d\u00e9charge (DoD), tandis que le mod\u00e8le MG 512314 indique 16,076 kWh, une tension comprise entre 40,0 V et 58,4 V, et \u2265 6 000 cycles \u00e0 25 \u00b0C et 80 % de la capacit\u00e9 r\u00e9siduelle (EOL). Ils ne doivent pas \u00eatre consid\u00e9r\u00e9s comme interchangeables sans v\u00e9rifier l'application sp\u00e9cifique et la compatibilit\u00e9 avec l'onduleur.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-4247\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"8\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-4247\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Pourquoi ne peut-on pas diviser directement les kWh mesur\u00e9s c\u00f4t\u00e9 courant alternatif par les kWh indiqu\u00e9s sur la plaque signal\u00e9tique c\u00f4t\u00e9 courant continu lors du calcul du taux de d\u00e9charge (DoD) ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-4247\" class=\"elementor-element elementor-element-ba306120 e-con-full e-flex e-con e-child\" data-id=\"ba306120\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-4247\" class=\"elementor-element elementor-element-ccab6072 e-con-full e-flex e-con e-child\" data-id=\"ccab6072\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-9beb3722 elementor-widget elementor-widget-heading\" data-id=\"9beb3722\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">En effet, la puissance de sortie en courant alternatif tient d\u00e9j\u00e0 compte des pertes de conversion de l'onduleur ou du PCS et peut \u00e9galement inclure les charges auxiliaires et les effets de chute de tension. Les calculs de profondeur de d\u00e9charge (DoD) doivent reposer sur une base coh\u00e9rente. Le fait de m\u00e9langer l'\u00e9nergie fournie en courant alternatif avec l'\u00e9nergie nominale indiqu\u00e9e sur la plaque signal\u00e9tique en courant continu donne un r\u00e9sultat fauss\u00e9 et peut conduire \u00e0 des conclusions erron\u00e9es concernant l'utilisation de la batterie.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-4248\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"9\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-4248\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Quelles protections contre les basses tensions les ing\u00e9nieurs doivent-ils v\u00e9rifier sur un syst\u00e8me de stockage d'\u00e9nergie par batterie au lithium (BESS) ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-4248\" class=\"elementor-element elementor-element-68d74570 e-con-full e-flex e-con e-child\" data-id=\"68d74570\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-4248\" class=\"elementor-element elementor-element-ea91586e e-con-full e-flex e-con e-child\" data-id=\"ea91586e\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-97fdeb4d elementor-widget elementor-widget-heading\" data-id=\"97fdeb4d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">V\u00e9rifiez ces trois niveaux s\u00e9par\u00e9ment : la r\u00e9serve de SoC op\u00e9rationnelle de l'onduleur ou du syst\u00e8me de gestion de l'\u00e9nergie (EMS), la logique de protection contre les sous-tensions et de r\u00e9tablissement du syst\u00e8me de gestion de la batterie (BMS), ainsi que la proc\u00e9dure de verrouillage en cas de d\u00e9faut de sous-tension grave. Ces trois niveaux ont des fonctions distinctes et ne doivent pas \u00eatre confondus les uns avec les autres.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-4249\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"10\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-4249\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Que doivent faire les op\u00e9rateurs si une batterie cesse de fonctionner en raison d'une tension insuffisante ou d'une suspicion de d\u00e9charge excessive ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-4249\" class=\"elementor-element elementor-element-d656fd9d e-con-full e-flex e-con e-child\" data-id=\"d656fd9d\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-4249\" class=\"elementor-element elementor-element-911e57fc e-con-full e-flex e-con e-child\" data-id=\"911e57fc\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-d0a1d3e2 elementor-widget elementor-widget-heading\" data-id=\"d0a1d3e2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Isolez imm\u00e9diatement toutes les charges externes, consultez la documentation sp\u00e9cifique au mod\u00e8le et d\u00e9terminez si l'appareil a simplement atteint sa limite normale de fonctionnement ou s'il est entr\u00e9 dans un \u00e9tat de d\u00e9faillance plus grave du BMS. Ne contournez pas le BMS et n'effectuez pas de charge forc\u00e9e. Un bloc de batteries fortement d\u00e9charg\u00e9 doit \u00eatre examin\u00e9 par MegSolid ou par un technicien qualifi\u00e9, conform\u00e9ment \u00e0 la proc\u00e9dure de r\u00e9cup\u00e9ration approuv\u00e9e.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-42410\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"11\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-42410\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Que doivent v\u00e9rifier les acheteurs am\u00e9ricains avant d'acheter une batterie \u00e0 d\u00e9charge profonde \u00e0 usage r\u00e9sidentiel ou C&amp;I ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-42410\" class=\"elementor-element elementor-element-197a23f9 e-con-full e-flex e-con e-child\" data-id=\"197a23f9\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-42410\" class=\"elementor-element elementor-element-d8832975 e-con-full e-flex e-con e-child\" data-id=\"d8832975\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-4cfc79c3 elementor-widget elementor-widget-heading\" data-id=\"4cfc79c3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Les acheteurs am\u00e9ricains doivent v\u00e9rifier les crit\u00e8res de test pr\u00e9cis du minist\u00e8re am\u00e9ricain de la D\u00e9fense (DoD), la dur\u00e9e de vie nominale indiqu\u00e9e, l'\u00e9nergie CA utilisable apr\u00e8s d\u00e9ductions li\u00e9es aux pertes de l'onduleur, le syst\u00e8me de protection contre les basses tensions propre \u00e0 chaque mod\u00e8le, ainsi que la compatibilit\u00e9 avec l'onduleur ou le syst\u00e8me de conversion de puissance (PCS). Les offres de batteries doivent \u00eatre compar\u00e9es sur la base des m\u00eames crit\u00e8res techniques, plut\u00f4t que sur la seule capacit\u00e9 nominale en kWh.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-42411\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"12\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-42411\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Que doivent v\u00e9rifier les EPC et les installateurs europ\u00e9ens dans une fiche technique relative \u00e0 la dur\u00e9e de vie utile (DoD) ou au cycle de vie ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-42411\" class=\"elementor-element elementor-element-a26c100f e-con-full e-flex e-con e-child\" data-id=\"a26c100f\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-42411\" class=\"elementor-element elementor-element-5d40ec43 e-con-full e-flex e-con e-child\" data-id=\"5d40ec43\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-0a196c88 elementor-widget elementor-widget-heading\" data-id=\"0a196c88\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Les certificats EPC europ\u00e9ens doivent confirmer la plage de tension d\u00e9clar\u00e9e, les valeurs en Ah et en kWh, le taux C ou le taux P ainsi que la temp\u00e9rature utilis\u00e9e lors de l'essai cyclique, le crit\u00e8re de fin de vie, et pr\u00e9ciser si la valeur publi\u00e9e correspond \u00e0 une cellule isol\u00e9e ou \u00e0 un syst\u00e8me complet. Ils doivent \u00e9galement v\u00e9rifier la communication avec l'onduleur et les param\u00e8tres de r\u00e9cup\u00e9ration en basse tension avant la mise en service.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-42412\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"13\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-42412\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Que doivent v\u00e9rifier les \u00e9tablissements commerciaux sud-africains avant de choisir une strat\u00e9gie de profondeur de d\u00e9charge (DoD) pour leurs batteries ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-42412\" class=\"elementor-element elementor-element-baeedece e-con-full e-flex e-con e-child\" data-id=\"baeedece\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-42412\" class=\"elementor-element elementor-element-99e37378 e-con-full e-flex e-con e-child\" data-id=\"99e37378\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-03eb30a2 elementor-widget elementor-widget-heading\" data-id=\"03eb30a2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Les acheteurs sud-africains C&amp;I doivent adapter la strat\u00e9gie de profondeur de cycle (DoD) aux plages tarifaires, au risque de coupure, \u00e0 la temp\u00e9rature ambiante et \u00e0 la r\u00e9serve de secours requise sur le site. Ils doivent v\u00e9rifier la r\u00e9serve quotidienne de niveau de charge (SoC) approuv\u00e9e, la plage de tension du syst\u00e8me de gestion de batterie (BMS) et la quantit\u00e9 r\u00e9elle de kWh CA utilisables apr\u00e8s prise en compte des pertes de conversion, plut\u00f4t que de se fier \u00e0 une simple valeur nominale isol\u00e9e.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-97f050b8 auto-p elementor-widget elementor-widget-heading\" data-id=\"97f050b8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Communiquez-nous le profil de charge de votre site, vos exigences en mati\u00e8re de coupures de courant ou la plage horaire quotidienne cible pour les cycles de charge\/d\u00e9charge, et notre \u00e9quipe d'ing\u00e9nieurs adaptera la batterie, l'onduleur et les param\u00e8tres de protection \u00e0 votre projet.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b8d09fb4 elementor-tablet-align-center elementor-align-center auto-cta elementor-widget elementor-widget-button\" data-id=\"b8d09fb4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"#elementor-action%3Aaction%3Dpopup%3Aopen%26settings%3DeyJpZCI6Ijk0OCIsInRvZ2dsZSI6ZmFsc2V9\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Contactez-nous pour une v\u00e9rification de la protection basse tension et de la compatibilit\u00e9 de l'onduleur<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Comprendre le taux de d\u00e9charge (DoD), les risques li\u00e9s \u00e0 une d\u00e9charge profonde, la dur\u00e9e de vie, la protection contre les sous-tensions du syst\u00e8me de gestion de batterie (BMS) et le dimensionnement de l'\u00e9nergie utilisable sur l'ensemble des plateformes BESS r\u00e9sidentielles et commerciales de MegSolid.<\/p>","protected":false},"author":4,"featured_media":7973,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"_joinchat":[],"footnotes":""},"categories":[1,712],"tags":[951,954,294,953,948,952,949,950,36,955],"class_list":["post-7977","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-bess","category-bess-product-comparisons","tag-battery-deep-discharge","tag-bms-low-voltage-protection","tag-commercial-bess","tag-cycle-life","tag-deep-discharge-battery","tag-deep-discharge-of-battery","tag-depth-of-discharge","tag-dod-battery","tag-MegSolid","tag-residential-energy-storage"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/posts\/7977","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/comments?post=7977"}],"version-history":[{"count":4,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/posts\/7977\/revisions"}],"predecessor-version":[{"id":7981,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/posts\/7977\/revisions\/7981"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/media\/7973"}],"wp:attachment":[{"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/media?parent=7977"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/categories?post=7977"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/tags?post=7977"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}