{"id":8238,"date":"2026-11-12T18:30:49","date_gmt":"2026-11-12T10:30:49","guid":{"rendered":"https:\/\/www.solidess.com\/?p=8238"},"modified":"2026-11-12T18:30:49","modified_gmt":"2026-11-12T10:30:49","slug":"sungrow-st5015kwh-2500kw-2h-powertitan-alternative-5000intl","status":"publish","type":"post","link":"https:\/\/www.solidess.com\/fr\/sungrow-st5015kwh-2500kw-2h-powertitan-alternative-5000intl\/","title":{"rendered":"Sungrow ST5015kWh-2500kW-2h (PowerTitan 2.0) Alternatives: Comparing MegSolid 5000INTL (2.7MW \/ 5.0159MWh)"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"8238\" class=\"elementor elementor-8238\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-bf4793c e-con-full auto-article-root e-flex e-con e-parent\" data-id=\"bf4793c\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-67813496 auto-p elementor-widget elementor-widget-heading\" data-id=\"67813496\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Utility-scale engineering contractors specifying a 20-foot 5mwh 2500kw 2h bess benchmark the st5015kwh-2500kw-2h (ST5015UX-2H), positioned by Sungrow as the 2.5 MW \/ 5 MWh sungrow powertitan 2.0 5mwh liquid-cooled energy storage system.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f7ccd796 auto-p elementor-widget elementor-widget-heading\" data-id=\"f7ccd796\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">While the ST5015kWh-2500kW-2h pairs 5,015 kWh of nominal DC capacity with a 2,500 kW rated AC active power output at 690 Vac, independent power producers (IPPs) and EPCs evaluate a second-source powertitan 2.0 alternative to diversify procurement or match higher active power dispatch targets.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4493f614 auto-p elementor-widget elementor-widget-heading\" data-id=\"4493f614\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Building on our commercial cabinet benchmark in <strong><a href=\"https:\/\/www.solidess.com\/fr\/alternatives-au-sungrow-powerstack-systeme-de-stockage-par-batterie-de-257-a-261-kwh-ci\/\" target=\"_blank\" style=\"color:#61ce70\">Alternatives au Sungrow PowerStack : comparaison des syst\u00e8mes de stockage C&amp;I de 257 \u00e0 261 kWh<\/a><\/strong>, this guide compares utility-scale 5 MWh container specifications side by side.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6607be63 auto-p elementor-widget elementor-widget-heading\" data-id=\"6607be63\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">For grid-scale and industrial substation tenders, the <strong><a href=\"https:\/\/www.solidess.com\/fr\/product\/systeme-de-stockage-denergie-conteneurise-megasolid-5000intl\/\" target=\"_blank\" style=\"color:#61ce70\">syst\u00e8me de stockage d'\u00e9nergie en conteneur MegSolid 5000INTL<\/a><\/strong> delivers 5,015.9 kWh of rated energy and 2,700 kW (450 kW x 6) of rated AC output at 690 Vac inside a 20-foot ISO container.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-81d0603b auto-p elementor-widget elementor-widget-heading\" data-id=\"81d0603b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Presented within our <strong><a href=\"https:\/\/www.solidess.com\/fr\/systemes-de-stockage-denergie-a-letat-solide\/\" target=\"_blank\" style=\"color:#61ce70\">MegSolid Solid-State Energy Storage Systems<\/a><\/strong> portfolio, the MegSolid 5000INTL uses a published SHS180-314 battery type code in a 12P416S configuration; its exact cell chemistry and electrolyte architecture should be confirmed against the supplied project BOM and controlled cell specification:<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b3ba1270 elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"b3ba1270\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">MegSolid 5000INTL (Utility Liquid-Cooled 20-ft Container): 2,700 kW (450 kW x 6 at 690 Vac, 50\/60 Hz) \/ 5,015.9 kWh rated energy, 1,331.2V DC rated (12P416S, SHS180-314 battery type code), 87.5% maximum efficiency, IP55, 6,058 x 2,438 x 2,896 mm<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">MegSolid ESSC0500B-1075 &amp; ESSC1000B-2150 (Air-Cooled Containers): 500 kW \/ 1.0752 MWh (20-ft) and 1,000 kW \/ 2.1504 MWh (40-ft) 3.2V \/ 280 Ah LFP containerized systems for medium-scale industrial feeders<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9191f2e3 auto-image elementor-widget elementor-widget-image\" data-id=\"9191f2e3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"1536\" height=\"864\" src=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/st5015-vs-5000intl-key-points-overview-1536x864.webp\" class=\"attachment-1536x1536 size-1536x1536 wp-image-8232\" alt=\"Key engineering differences between Sungrow ST5015 and MegSolid 5000INTL including active power, PCS kVA, cell count, 690 V output and delivered AC energy\" srcset=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/st5015-vs-5000intl-key-points-overview-1536x864.webp 1536w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/st5015-vs-5000intl-key-points-overview-300x169.webp 300w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/st5015-vs-5000intl-key-points-overview-1024x576.webp 1024w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/st5015-vs-5000intl-key-points-overview-768x432.webp 768w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/st5015-vs-5000intl-key-points-overview-2048x1152.webp 2048w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/st5015-vs-5000intl-key-points-overview-18x10.webp 18w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/st5015-vs-5000intl-key-points-overview-600x338.webp 600w\" sizes=\"(max-width: 1536px) 100vw, 1536px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-74824d10 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"74824d10\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Datasheet Comparison: Sungrow ST5015kWh-2500kW-2h (IEC Reference) vs. MegSolid 5000INTL<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-dd64ae04 auto-p elementor-widget elementor-widget-heading\" data-id=\"dd64ae04\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Evaluating a utility containerized bess requires comparing published electrical, thermal, and mechanical parameters across defined regional datasheet versions.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-91866363 auto-p elementor-widget elementor-widget-heading\" data-id=\"91866363\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Note that Sungrow publishes distinct regional specifications for the PowerTitan 2.0 (ST5015kWh-2500kW-2h \/ ST5015UX-2H) across Global\/IEC and North American (US) markets, which differ in maximum altitude ratings (4,000 m vs. 4,500 m on select regional sheets), fire protection options, enclosure classifications (IP55 vs. Type 3S), and grid frequency settings.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d1652767 auto-p elementor-widget elementor-widget-heading\" data-id=\"d1652767\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">The table below references the Sungrow Global\/IEC ST5015kWh-2500kW-2h (ST5015UX-2H) specification alongside published parameters for the MegSolid 5000INTL.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e08d86e9 auto-table elementor-widget elementor-widget-text-editor\" data-id=\"e08d86e9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"cea-table-wrap\"><table><thead><tr><th>Specification Parameter<\/th><th>Sungrow PowerTitan 2.0 (ST5015kWh-2500kW-2h IEC Sheet)<\/th><th>MegSolid 5000INTL Utility Container<\/th><th>Engineering &amp; Sizing Notes<\/th><\/tr><\/thead><tbody><tr><td>System Model Designation<\/td><td>ST5015kWh-2500kW-2h (ST5015UX-2H 2.5MW\/5MWh)<\/td><td>5000INTL<\/td><td>Both target 5 MWh-class 20-foot utility deployments<\/td><\/tr><tr><td>Nominal \/ Rated Energy Capacity<\/td><td>5,015 kWh nominal DC capacity<\/td><td>5,015.9 kWh rated energy<\/td><td>String math: 12 \u00d7 416 \u00d7 3.2V \u00d7 314Ah = 5,015.96 kWh<\/td><\/tr><tr><td>System Rated AC Active Power<\/td><td>2,500 kW<\/td><td>2,700 kW (450 kW x 6)<\/td><td>5000INTL provides +200 kW (+8.0%) higher rated AC active power<\/td><\/tr><tr><td>PCS Apparent \/ Module Rating<\/td><td>210 kVA x 12 = 2,520 kVA total apparent power<\/td><td>450 kW x 6 multi-modular PCS<\/td><td>Distinguish system active power (kW) from PCS apparent power (kVA)<\/td><\/tr><tr><td>Nominal AC Voltage &amp; Frequency<\/td><td>690 Vac (621V to 759V IEC range), 50 Hz (60 Hz on US variant)<\/td><td>690 V CA, 50\/60 Hz<\/td><td>Both connect to the 690 Vac low-voltage winding of an MV transformer<\/td><\/tr><tr><td>Published Cell Type \/ Code<\/td><td>3.2V \/ 314 Ah LFP<\/td><td>SHS180-314 published battery type code (derived 314 Ah at 1,331.2V \/ 12P416S)<\/td><td>Confirm 5000INTL cell BOM and electrolyte spec per project<\/td><\/tr><tr><td>Battery String Architecture<\/td><td>416S12P (12 strings of 416S)<\/td><td>12P416S (12 strings of 416S)<\/td><td>Identical series-parallel cell count (4,992 cells per container)<\/td><\/tr><tr><td>DC Voltage Window<\/td><td>1,123.2V to 1,497.6V DC (1,331.2V nominal)<\/td><td>1,331.2V DC rated (illustrative 416S window: 1,123.2V\u20131,497.6V at 2.7\u20133.6V\/cell)<\/td><td>Maximum DC operating voltage approaches 1,500V DC<\/td><\/tr><tr><td>Published System Efficiency<\/td><td>Not stated as a single fixed figure on base sheet<\/td><td>Rendement maximal de 87,51 TP5T<\/td><td>Align efficiency boundaries and auxiliary loads in LCOS models<\/td><\/tr><tr><td>Gestion thermique<\/td><td>Refroidissement par liquide intelligent<\/td><td>Refroidissement par liquide intelligent<\/td><td>Liquid coolant loops regulate 416S battery strings<\/td><\/tr><tr><td>Enclosure Dimensions (W x D x H)<\/td><td>6,058 x 2,438 x 2,896 mm<\/td><td>6,058 x 2,438 x 2,896 mm<\/td><td>Standard 20-foot ISO High-Cube footprint (14.77 m\u00b2 base area)<\/td><\/tr><tr><td>System Weight<\/td><td>~42,500 kg (published on Sungrow datasheet)<\/td><td>Confirm via controlled project GA drawing<\/td><td>Size pads using controlled net weight, operating weight, and CoG drawings<\/td><\/tr><tr><td>Ingress Protection &amp; Max Altitude<\/td><td>IP55, &lt;= 4,000 m (up to 4,500 m on select regional sheets)<\/td><td>IP55, &lt;= 4,000 m<\/td><td>Verify regional datasheet version for high-altitude sites<\/td><\/tr><tr><td>Interfaces de communication<\/td><td>Ethernet<\/td><td>Confirm SCADA\/EMS interface per project specification<\/td><td>Verify communication port and register map before integration<\/td><\/tr><\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9fbc157d auto-image elementor-widget elementor-widget-image\" data-id=\"9fbc157d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"1536\" height=\"864\" src=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/st5015-vs-5000intl-datasheet-comparison-1536x864.webp\" class=\"attachment-1536x1536 size-1536x1536 wp-image-8233\" alt=\"IEC datasheet comparison of Sungrow ST5015 5,015 kWh and 2,500 kW with MegSolid 5000INTL 5,015.9 kWh and 2,700 kW at 690 Vac\" srcset=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/st5015-vs-5000intl-datasheet-comparison-1536x864.webp 1536w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/st5015-vs-5000intl-datasheet-comparison-300x169.webp 300w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/st5015-vs-5000intl-datasheet-comparison-1024x576.webp 1024w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/st5015-vs-5000intl-datasheet-comparison-768x432.webp 768w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/st5015-vs-5000intl-datasheet-comparison-18x10.webp 18w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/st5015-vs-5000intl-datasheet-comparison-600x338.webp 600w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/st5015-vs-5000intl-datasheet-comparison.webp 2048w\" sizes=\"(max-width: 1536px) 100vw, 1536px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7a40ffaf auto-h2 elementor-widget elementor-widget-heading\" data-id=\"7a40ffaf\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Key Architectural Differences: Power Ratings, Cell Configuration, and Delivered Energy<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a97a4612 auto-p elementor-widget elementor-widget-heading\" data-id=\"a97a4612\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">While both containers share an identical 6,058 x 2,438 x 2,896 mm envelope and a 4,992-cell (12 x 416S) layout, engineering teams must evaluate three technical distinctions during tender review.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-15de532b auto-h3 elementor-widget elementor-widget-heading\" data-id=\"15de532b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">1. System Active Power (kW) vs. PCS Apparent Power (kVA): 2,700 kW vs. 2,500 kW<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-865fea10 auto-p elementor-widget elementor-widget-heading\" data-id=\"865fea10\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">On Sungrow's official specification sheet for the st5015kwh-2500kw-2h, system rated active power is 2,500 kW, while the twelve modular converters are rated in apparent power at 210 kVA \u00d7 12 = 2,520 kVA.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8464a3f2 auto-p elementor-widget elementor-widget-heading\" data-id=\"8464a3f2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Engineers must keep active power (kW) and apparent power (kVA) distinct when modeling reactive power capability.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-338001f1 auto-p elementor-widget elementor-widget-heading\" data-id=\"338001f1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">By comparison, the MegSolid 5000intl specifies six 450 kW power conversion units (450 kW x 6), delivering a combined rated AC active power of 2,700 kW at 690 Vac:<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c9743cc2 auto-p elementor-widget elementor-widget-heading\" data-id=\"c9743cc2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">P_AC (5000INTL) = 6 \u00d7 450 kW = 2,700 kW (+200 kW, or +8.0% vs. 2,500 kW).<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a376051d auto-p elementor-widget elementor-widget-heading\" data-id=\"a376051d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Note that nominal duration ratios such as 2.0 hours (5,015 kWh \/ 2,500 kW at a nominal 0.5P ratio) or ~1.86 hours (5,015.9 kWh \/ 2,700 kW) reflect the ratio of rated DC energy to rated AC power, and do not represent guaranteed point-of-interconnection (POI) AC discharge duration.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d4d874e2 auto-p elementor-widget elementor-widget-heading\" data-id=\"d4d874e2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Whether the 5000INTL can sustain 2,500 kW or 2,700 kW at the POI for a contracted duration depends on usable depth of discharge (DoD), conversion efficiency, auxiliary cooling power, and cell degradation curves.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6a451d65 auto-p elementor-widget elementor-widget-heading\" data-id=\"6a451d65\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">The additional 200 kW of rated active power may provide higher dispatch headroom, subject to the PCS overload curve, ramp-rate capability, battery current limits, grid-code requirements, and operating SoC.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4a8f0587 auto-p elementor-widget elementor-widget-heading\" data-id=\"4a8f0587\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Because the 5000INTL pairs 12 battery strings (12P416S) with six 450 kW PCS units (without public datasheet confirmation of whether two strings share a PCS DC bus or use separate DC\/DC stages), electrical engineers must verify DC-side string grouping and fuse protection philosophy against factory single-line diagrams.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1a01cbbd auto-h3 elementor-widget elementor-widget-heading\" data-id=\"1a01cbbd\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">2. Cell Architecture: Sungrow Liquid LFP vs. MegSolid SHS180-314 Battery Configuration<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-89a86b10 auto-p elementor-widget elementor-widget-heading\" data-id=\"89a86b10\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">The Sungrow ST5015kWh-2500kW-2h datasheet specifies 3.2V \/ 314 Ah liquid LFP cells arranged in a 416S12P configuration.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-35236855 auto-p elementor-widget elementor-widget-heading\" data-id=\"35236855\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">For the MegSolid 5000INTL, the official container specification confirms a 12P416S configuration using the SHS180-314 battery type code at 1,331.2V DC rated voltage and 5,015.9 kWh rated energy, paired with smart liquid cooling, AI early warning, and a three-dimensional protection system.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0e942c56 auto-p elementor-widget elementor-widget-heading\" data-id=\"0e942c56\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">While MegSolid separately publishes a cell specification brief for the <strong><a href=\"https:\/\/www.solidess.com\/fr\/batterie-a-letat-solide-hybride-megsolid-314ah\/\" target=\"_blank\" style=\"color:#61ce70\">MegSolid 314Ah Hybrid Solid-State Battery<\/a><\/strong> (SHS180-314Ah, listing 3.2V \/ 314 Ah, 180 Wh\/kg, 390 Wh\/L, ACIR 0.18 +\/- 0.03 milliohms, DCIR 0.4 +\/- 0.1 milliohms, and &gt;= 94.5% cell efficiency at 0.5P), the 5000INTL container page does not independently detail the complete electrolyte composition.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-60f1eed4 auto-p elementor-widget elementor-widget-heading\" data-id=\"60f1eed4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Therefore, procurement engineers should not automatically transfer all standalone cell brief metrics onto the container without confirming the exact cell chemistry, electrolyte architecture, and safety test reports against the supplied project BOM.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b94cac40 auto-h3 elementor-widget elementor-widget-heading\" data-id=\"b94cac40\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">3. Distinguishing Rated DC Energy from Net Delivered AC Energy<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-bc9a863c auto-p elementor-widget elementor-widget-heading\" data-id=\"bc9a863c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Both the ST5015kWh-2500kW-2h (5,015 kWh) and the 5000INTL (5,015.9 kWh) express nameplate capacity as rated DC cell energy (12 \u00d7 416 \u00d7 3.2V \u00d7 314Ah = 5,015.96 kWh).<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-da4946b8 auto-p elementor-widget elementor-widget-heading\" data-id=\"da4946b8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">MegSolid publishes an 87.5% Maximum Efficiency figure for the 5000INTL, which does not specify whether the measurement boundary covers full-cycle AC-to-AC round-trip efficiency or includes auxiliary chiller power.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8a676304 auto-p elementor-widget elementor-widget-heading\" data-id=\"8a676304\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">For illustration only, if 87.5% were assumed to represent the applicable DC-to-AC conversion efficiency, a 90% usable DoD would yield approximately 3,950 kWh before accounting for auxiliary consumption:<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6209c051 auto-p elementor-widget elementor-widget-heading\" data-id=\"6209c051\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Illustrative delivered energy = 5,015.9 kWh \u00d7 90% DoD \u00d7 87.5% assumed efficiency \u2248 3,950.0 kWh (before auxiliary loads).<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-29ca85d9 auto-p elementor-widget elementor-widget-heading\" data-id=\"29ca85d9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">This is not a guaranteed AC-to-AC round-trip energy rating; actual project sizing must use verified efficiency curves across operating C-rates and deduct site-specific liquid-cooling auxiliary loads.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6fc7b3d1 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"6fc7b3d1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Balance-of-Plant (BoP) Engineering: 690V AC Step-Up Transformer Integration<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8189ec3e auto-p elementor-widget elementor-widget-heading\" data-id=\"8189ec3e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Evaluating a powertitan 2.0 alternative requires checking how the container interfaces with medium-voltage (MV) collector substations.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3e0ee58c auto-h3 elementor-widget elementor-widget-heading\" data-id=\"3e0ee58c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Connecting to the 690V Low-Voltage Winding of an MV Step-Up Transformer<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8bbc0ee0 auto-p elementor-widget elementor-widget-heading\" data-id=\"8bbc0ee0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Both systems provide 690 Vac three-phase output for connection to the low-voltage winding of a suitably rated medium-voltage step-up transformer (where the medium-voltage primary winding steps up to 10 kV, 20 kV, 33 kV, or 34.5 kV).<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7b6e883e auto-p elementor-widget elementor-widget-heading\" data-id=\"7b6e883e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">In an illustrative substation topology where two containers feed a dual-split-winding step-up transformer skid:<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-61d62864 elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"61d62864\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Two Sungrow ST5015kWh-2500kW-2h Units: 2 \u00d7 2,500 kW = 5,000 kW rated active power (2 \u00d7 2,520 kVA = 5,040 kVA PCS apparent rating)<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Two MegSolid 5000INTL Units: 2 \u00d7 2,700 kW = 5,400 kW rated active power at 690 Vac<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c07a2c6e auto-p elementor-widget elementor-widget-heading\" data-id=\"c07a2c6e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Matching the 690 Vac nominal voltage does not mean an EPC can swap containers without re-verifying the transformer and low-voltage switchgear.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b462bc62 auto-p elementor-widget elementor-widget-heading\" data-id=\"b462bc62\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Engineers must check five electrical and mechanical interface parameters:<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-63a4b2af elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"63a4b2af\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Transformer MVA Capacity and Power Factor Range: Verify that the step-up transformer has sufficient MVA rating for 2 \u00d7 2,700 kW = 5.4 MW plus required reactive power (kVAr), or cap container dispatch at 2,500 kW via EMS control.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Short-Circuit Impedance, Winding Vector Group, and Protection: Confirm transformer percentage impedance (Z%), winding connection group (such as Dyn11 or YNd11), fault current contribution, and relay coordination.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">PCS Grid-Code Control and Harmonics: Verify PCS harmonic distortion limits (such as THDi &lt; 3% on Sungrow&#039;s sheet), anti-islanding protection, and SCADA\/EMS communication register maps.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Low-Voltage Breaker and Cable Sizing: At 690 Vac and unity power factor (PF = 1.0), theoretical three-phase line current (I = P \/ (\u221a3 \u00d7 690V \u00d7 PF)) is 2,092 A for 2,500 kW and 2,259 A for 2,700 kW; however, actual breaker and cable selection must be sized for rated power factor, maximum continuous current, temperature rise, ambient derating, and continuous load factors.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Foundation Loads and Center-of-Gravity Drawings: While both containers share identical 6,058 x 2,438 x 2,896 mm outer dimensions (14.77 m\u00b2 footprint) and Sungrow specifies ~42,500 kg, civil engineers must calculate pad bearing loads using controlled net weight, operating weight, and center-of-gravity (CoG) drawings for the exact supplied model.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d6b96705 auto-image elementor-widget elementor-widget-image\" data-id=\"d6b96705\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"1536\" height=\"864\" src=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/extra-200kw-substation-impact-5000intl-1536x864.webp\" class=\"attachment-1536x1536 size-1536x1536 wp-image-8234\" alt=\"Illustrative two-container substation comparison showing 5,400 kW MegSolid 5000INTL versus 5,000 kW Sungrow ST5015 output and theoretical 690 Vac line currents\" srcset=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/extra-200kw-substation-impact-5000intl-1536x864.webp 1536w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/extra-200kw-substation-impact-5000intl-300x169.webp 300w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/extra-200kw-substation-impact-5000intl-1024x576.webp 1024w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/extra-200kw-substation-impact-5000intl-768x432.webp 768w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/extra-200kw-substation-impact-5000intl-18x10.webp 18w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/extra-200kw-substation-impact-5000intl-600x338.webp 600w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/extra-200kw-substation-impact-5000intl.webp 2048w\" sizes=\"(max-width: 1536px) 100vw, 1536px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b05898b6 elementor-tablet-align-center elementor-align-center auto-cta elementor-widget elementor-widget-button\" data-id=\"b05898b6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"#elementor-action%3Aaction%3Dpopup%3Aopen%26settings%3DeyJpZCI6Ijk0OCIsInRvZ2dsZSI6ZmFsc2V9\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Contact Us for a 690 V Transformer, Switchgear and Breaker Compatibility Review<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-06371ded auto-h2 elementor-widget elementor-widget-heading\" data-id=\"06371ded\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Evaluating 1 MWh to 2 MWh Industrial Feeders: Air-Cooled Container Options<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6afd35ef auto-p elementor-widget elementor-widget-heading\" data-id=\"6afd35ef\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">For industrial feeders that do not require a 5 MWh liquid-cooled block, MegSolid manufactures the <strong><a href=\"https:\/\/www.solidess.com\/fr\/product\/systeme-de-stockage-denergie-conteneurise\/\" target=\"_blank\" style=\"color:#61ce70\">MegSolid Containerized Energy Storage System<\/a><\/strong> (ESSC series) using 3.2V \/ 280 Ah LFP cells (&gt;= 5,000 cycles) and intelligent temperature-controlled air cooling (IP54).<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1a177359 auto-p elementor-widget elementor-widget-heading\" data-id=\"1a177359\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Across the ESSC product specification, maximum PV input power is published at the series level as selectable configuration options (600 \/ 660 \/ 720 \/ 1,200 \/ 1,320 \/ 1,440 kW, confirmed per model and MPPT order configuration):<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-54c9c9c1 elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"54c9c9c1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">ESSC0500B-1075 (20-Foot Container): 500 kW rated AC power \/ 1.0752 MWh nominal energy, 6,058 x 2,438 x 2,896 mm, 21,000 kg (confirm selected PV input configuration option from series table)<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">ESSC1000B-2150 (40-Foot Container): 1,000 kW rated AC power \/ 2.1504 MWh nominal energy, 12,192 x 2,438 x 2,896 mm, 38,000 kg (confirm selected PV input configuration option from series table)<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-91c6d44f auto-h2 elementor-widget elementor-widget-heading\" data-id=\"91c6d44f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">How EPCs Model 20-Year Lifecycle Cost (LCOS) and Procurement Risk<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9438a269 auto-p elementor-widget elementor-widget-heading\" data-id=\"9438a269\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">When comparing the sungrow powertitan 2.0 5mwh against the MegSolid 5000intl for a multi-year Power Purchase Agreement (PPA), procurement teams must evaluate contracted testing protocols and verified financial model inputs.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6d68ef18 auto-h3 elementor-widget elementor-widget-heading\" data-id=\"6d68ef18\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Supply Chain Scheduling and Contractual FAT Protocols<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1e748072 auto-p elementor-widget elementor-widget-heading\" data-id=\"1e748072\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">On utility and industrial tenders, production slot allocation and shipping schedules directly impact Commercial Operation Date (COD) milestones.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b8c5d8ac auto-p elementor-widget elementor-widget-heading\" data-id=\"b8c5d8ac\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">EPCs procuring the 5000INTL can coordinate delivery schedules, SCADA protocol mapping, factory burn-in testing scope, and customer witness Factory Acceptance Testing (FAT) procedures according to the terms defined in the project supply contract and approved FAT plan.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e98d5515 auto-h3 elementor-widget elementor-widget-heading\" data-id=\"e98d5515\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Five Required Inputs for a Rigorous 20-Year Container LCOS Model<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-31f54c4c auto-p elementor-widget elementor-widget-heading\" data-id=\"31f54c4c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Building a bankable 20-year Levelized Cost of Storage (LCOS) comparison between two 5 MWh containers requires five project-specific inputs:<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ffdc99df elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"ffdc99df\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Turnkey Equipment and BoP CAPEX: Confirmed container FOB\/CIF pricing, MV transformer skids, civil foundations, and grid interconnection costs<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Full-Cycle AC Efficiency and Auxiliary Load Curves: Verified AC-to-AC round-trip efficiency curves at the project's C-rate and ambient temperature profile, minus liquid-cooling chiller consumption<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Warranted Cycle Life and Degradation Curves: Controlled annual State of Health (SoH) retention tables under the contracted cycling regime<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Augmentation Evaluation Variables: Modeling whether (and in which specific year) supplemental capacity or repowering is required to maintain contracted POI megawatt-hours<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Discount Rate and Delivered AC Energy Normalization: 20-year cumulative Net Present Value (NPV) of all CAPEX and OPEX divided by discounted net AC megawatt-hours delivered to the grid<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-f1cc8c39 auto-faq e-flex e-con-boxed e-con e-child\" data-id=\"f1cc8c39\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-cffc5278 elementor-widget elementor-widget-heading\" data-id=\"cffc5278\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">FAQ<\/h2>\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-38720b50 e-con-full e-flex e-con e-child\" data-id=\"38720b50\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-3cf9830a elementor-widget elementor-widget-n-accordion\" data-id=\"3cf9830a\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;default_state&quot;:&quot;all_collapsed&quot;,&quot;max_items_expended&quot;:&quot;one&quot;,&quot;n_accordion_animation_duration&quot;:{&quot;unit&quot;:&quot;ms&quot;,&quot;size&quot;:400,&quot;sizes&quot;:[]}}\" data-widget_type=\"nested-accordion.default\">\n\t\t\t\t\t\t\t<div class=\"e-n-accordion\" aria-label=\"Accord\u00e9on. Ouvrez les liens \u00e0 l&#039;aide de la touche Entr\u00e9e ou de la barre d&#039;espace, fermez-les avec la touche \u00c9chap et naviguez \u00e0 l&#039;aide des touches fl\u00e9ch\u00e9es.\">\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-1020\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"1\" tabindex=\"0\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-1020\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> What are the confirmed specification differences between Sungrow ST5015kWh-2500kW-2h and MegSolid 5000INTL? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-1020\" class=\"elementor-element elementor-element-57192144 e-con-full e-flex e-con e-child\" data-id=\"57192144\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-1020\" class=\"elementor-element elementor-element-f12e24a5 e-con-full e-flex e-con e-child\" data-id=\"f12e24a5\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-5957cb53 elementor-widget elementor-widget-heading\" data-id=\"5957cb53\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Both systems are 20-foot ISO High-Cube liquid-cooled containers (6,058 x 2,438 x 2,896 mm, IP55) storing approximately 5.015 MWh (5,015 kWh nominal for Sungrow vs. 5,015.9 kWh rated for MegSolid) across 4,992 cells (12 x 416S) with a 690 Vac three-phase output. The primary confirmed datasheet difference is rated AC active power: the MegSolid 5000INTL is rated at 2,700 kW (450 kW x 6), which is 200 kW (+8.0%) higher than the Sungrow ST5015kWh-2500kW-2h active power rating of 2,500 kW (2,520 kVA apparent power across 210 kVA x 12).<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-1021\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"2\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-1021\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Why is the MegSolid 5000INTL rated at 5,015.9 kWh, and how is its cell type defined? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-1021\" class=\"elementor-element elementor-element-939aa548 e-con-full e-flex e-con e-child\" data-id=\"939aa548\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-1021\" class=\"elementor-element elementor-element-6466d392 e-con-full e-flex e-con e-child\" data-id=\"6466d392\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-4b3675dd elementor-widget elementor-widget-heading\" data-id=\"4b3675dd\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">The 5000INTL uses a 12P416S configuration with a published SHS180-314 battery type code and a rated DC voltage of 416 \u00d7 3.2V = 1,331.2 Vdc, yielding 12 \u00d7 1,331.2V \u00d7 314Ah = 5,015.96 kWh (listed as 5,015.9 kWh rated energy). Its exact cell chemistry and electrolyte architecture should be confirmed against the supplied project BOM and controlled cell specification.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-1022\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"3\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-1022\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Does a 5,015.9 kWh rated container deliver 5 MWh of net AC energy to the grid? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-1022\" class=\"elementor-element elementor-element-844457f3 e-con-full e-flex e-con e-child\" data-id=\"844457f3\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-1022\" class=\"elementor-element elementor-element-762a756f e-con-full e-flex e-con e-child\" data-id=\"762a756f\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a42b9bb1 elementor-widget elementor-widget-heading\" data-id=\"a42b9bb1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">No, 5,015.9 kWh is the rated DC capacity rather than net delivered AC energy at the point of interconnection. For illustration only, if 87.5% were assumed to represent the applicable DC-to-AC conversion efficiency, a 90% usable DoD would yield approximately 3,950 kWh before accounting for auxiliary consumption; this is not a guaranteed AC-to-AC round-trip energy rating.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-1023\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"4\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-1023\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Can the MegSolid 5000INTL connect to a 690V medium-voltage step-up transformer? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-1023\" class=\"elementor-element elementor-element-f4722a49 e-con-full e-flex e-con e-child\" data-id=\"f4722a49\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-1023\" class=\"elementor-element elementor-element-8c60a06d e-con-full e-flex e-con e-child\" data-id=\"8c60a06d\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-bea32087 elementor-widget elementor-widget-heading\" data-id=\"bea32087\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Both systems provide 690 Vac three-phase output for connection to the low-voltage winding of a suitably rated medium-voltage step-up transformer. However, replacing a 2,500 kW unit with a 2,700 kW unit requires verifying transformer MVA capacity, power factor and reactive power range, short-circuit impedance, winding connection group, protection coordination, and low-voltage breaker\/cable sizing.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-1024\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"5\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-1024\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> How do the PCS ratings differ between the 5000INTL and PowerTitan 2.0? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-1024\" class=\"elementor-element elementor-element-98805c18 e-con-full e-flex e-con e-child\" data-id=\"98805c18\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-1024\" class=\"elementor-element elementor-element-628d52a4 e-con-full e-flex e-con e-child\" data-id=\"628d52a4\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-3b7b7f0e elementor-widget elementor-widget-heading\" data-id=\"3b7b7f0e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">The Sungrow ST5015kWh-2500kW-2h datasheet specifies a 2,500 kW system active power rating and twelve 210 kVA modular PCS units (2,520 kVA total apparent power). The MegSolid 5000INTL specifies six 450 kW power conversion units (450 kW x 6) for 2,700 kW total rated AC active power, and engineers should confirm the internal DC string-to-PCS grouping against factory drawings.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-1025\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"6\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-1025\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> How does the standalone SHS180-314Ah cell brief relate to the 5000INTL container? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-1025\" class=\"elementor-element elementor-element-4f1ef5cd e-con-full e-flex e-con e-child\" data-id=\"4f1ef5cd\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-1025\" class=\"elementor-element elementor-element-5df5523c e-con-full e-flex e-con e-child\" data-id=\"5df5523c\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-04f0d23c elementor-widget elementor-widget-heading\" data-id=\"04f0d23c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">MegSolid publishes a standalone cell technical brief for the SHS180-314Ah hybrid solid-state LFP cell (3.2V \/ 314 Ah, 180 Wh\/kg, 390 Wh\/L, ACIR 0.18 +\/- 0.03 milliohms, DCIR 0.4 +\/- 0.1 milliohms, &gt;= 94.5% cell efficiency at 0.5P). Because the 5000INTL container page lists the SHS180-314 type code without detailing full electrolyte parameters, EPCs should verify the controlled cell specification in their project BOM.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-1026\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"7\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-1026\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> What are the dimensions, weight, and altitude considerations for both containers? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-1026\" class=\"elementor-element elementor-element-6f405ec8 e-con-full e-flex e-con e-child\" data-id=\"6f405ec8\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-1026\" class=\"elementor-element elementor-element-5613b55a e-con-full e-flex e-con e-child\" data-id=\"5613b55a\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-63b12e30 elementor-widget elementor-widget-heading\" data-id=\"63b12e30\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Both containers share a 20-foot High-Cube footprint of 6,058 x 2,438 x 2,896 mm (14.77 m\u00b2 base area) and an IP55 rating, with max altitude listed up to 4,000 m on standard IEC sheets (and 4,500 m on select Sungrow regional sheets). While Sungrow's datasheet lists a weight of ~42,500 kg, foundation and crane calculations for the 5000INTL must be based on MegSolid's controlled net weight, operating weight, and center-of-gravity drawings.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-1027\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"8\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-1027\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> How should EPCs treat the 87.5% maximum efficiency figure on the 5000INTL? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-1027\" class=\"elementor-element elementor-element-62275c58 e-con-full e-flex e-con e-child\" data-id=\"62275c58\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-1027\" class=\"elementor-element elementor-element-49205416 e-con-full e-flex e-con e-child\" data-id=\"49205416\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-65652e67 elementor-widget elementor-widget-heading\" data-id=\"65652e67\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">MegSolid lists 87.5% as a Maximum Efficiency parameter on the 5000INTL specification sheet without defining full-cycle AC-to-AC round-trip boundaries. Financial models should request full-cycle AC-to-AC round-trip efficiency curves and auxiliary thermal load tables across project C-rates and ambient temperatures.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-1028\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"9\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-1028\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> How should EPCs verify SCADA and EMS communication interfaces for the 5000INTL? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-1028\" class=\"elementor-element elementor-element-d1b6ad20 e-con-full e-flex e-con e-child\" data-id=\"d1b6ad20\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-1028\" class=\"elementor-element elementor-element-1245cd3f e-con-full e-flex e-con e-child\" data-id=\"1245cd3f\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-448421ee elementor-widget elementor-widget-heading\" data-id=\"448421ee\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">While Sungrow's ST5015kWh-2500kW-2h datasheet specifies Ethernet communication, MegSolid's base web summary for the 5000INTL does not list specific communication port protocols. EPC automation engineers should confirm the physical communication interface, protocol standard (such as Modbus TCP\/RTU or IEC 61850), and SCADA register map in the project technical specification.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-1029\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"10\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-1029\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Does MegSolid offer smaller containerized BESS options for 1 MWh to 2 MWh projects? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-1029\" class=\"elementor-element elementor-element-29826983 e-con-full e-flex e-con e-child\" data-id=\"29826983\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-1029\" class=\"elementor-element elementor-element-05650135 e-con-full e-flex e-con e-child\" data-id=\"05650135\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-657ee16d elementor-widget elementor-widget-heading\" data-id=\"657ee16d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Yes, MegSolid offers the air-cooled ESSC0500B-1075 (500 kW \/ 1.0752 MWh in a 20-foot container) and ESSC1000B-2150 (1,000 kW \/ 2.1504 MWh in a 40-foot container), with selectable series PV input options (600 \/ 660 \/ 720 \/ 1,200 \/ 1,320 \/ 1,440 kW) confirmed per order configuration.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ba28be74 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"ba28be74\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Conclusion: Engineering a Reliable 5 MWh Utility Storage Deployment<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8d509307 auto-p elementor-widget elementor-widget-heading\" data-id=\"8d509307\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Evaluating a sungrow powertitan 2.0 5mwh system against a powertitan 2.0 alternative requires verifying active vs. apparent PCS power ratings, 690 Vac low-voltage transformer winding compatibility, controlled BOM cell specifications, and net delivered AC energy.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-bffe9297 auto-p elementor-widget elementor-widget-heading\" data-id=\"bffe9297\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">For commercial and utility engineering comparisons across our product lineup, review <strong><a href=\"https:\/\/www.solidess.com\/fr\/alternatives-au-sungrow-powerstack-systeme-de-stockage-par-batterie-de-257-a-261-kwh-ci\/\" target=\"_blank\" style=\"color:#61ce70\">Alternatives au Sungrow PowerStack : comparaison des syst\u00e8mes de stockage C&amp;I de 257 \u00e0 261 kWh<\/a><\/strong>.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6523b2ea auto-p elementor-widget elementor-widget-heading\" data-id=\"6523b2ea\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Explore full technical documentation for the <strong><a href=\"https:\/\/www.solidess.com\/fr\/product\/systeme-de-stockage-denergie-conteneurise-megasolid-5000intl\/\" target=\"_blank\" style=\"color:#61ce70\">syst\u00e8me de stockage d'\u00e9nergie en conteneur MegSolid 5000INTL<\/a><\/strong> and our complete range of <strong><a href=\"https:\/\/www.solidess.com\/fr\/systemes-de-stockage-denergie-a-letat-solide\/\" target=\"_blank\" style=\"color:#61ce70\">MegSolid Solid-State Energy Storage Systems<\/a><\/strong>.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-cab474c6 elementor-tablet-align-center elementor-align-center auto-cta elementor-widget elementor-widget-button\" data-id=\"cab474c6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"#elementor-action%3Aaction%3Dpopup%3Aopen%26settings%3DeyJpZCI6Ijk0OCIsInRvZ2dsZSI6ZmFsc2V9\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Contact Us to Receive Controlled GA Drawings, BMS\/EMS Protocol Tables and a Project-Specific 5000INTL Quotation<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Compare Sungrow\u2019s ST5015 5 MWh PowerTitan 2.0 container with MegSolid 5000INTL across rated AC power, DC energy, 690 Vac transformer integration, cell configuration, efficiency boundaries and EPC procurement checks.<\/p>","protected":false},"author":4,"featured_media":8231,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"_joinchat":[],"footnotes":""},"categories":[1,712],"tags":[1014,1017,611,462,1015,1012,1013,1016],"class_list":["post-8238","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-bess","category-bess-product-comparisons","tag-5mwh-2500kw-2h-bess","tag-5mwh-battery-energy-storage","tag-690v-bess","tag-megsolid-5000intl","tag-powertitan-2-0-alternative","tag-st5015kwh-2500kw-2h","tag-sungrow-powertitan-2-0","tag-utility-containerized-bess"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/posts\/8238","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/comments?post=8238"}],"version-history":[{"count":4,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/posts\/8238\/revisions"}],"predecessor-version":[{"id":8242,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/posts\/8238\/revisions\/8242"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/media\/8231"}],"wp:attachment":[{"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/media?parent=8238"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/categories?post=8238"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/tags?post=8238"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}