{"id":8426,"date":"2026-11-13T16:06:09","date_gmt":"2026-11-13T08:06:09","guid":{"rendered":"https:\/\/www.solidess.com\/?p=8426"},"modified":"2026-11-13T16:06:09","modified_gmt":"2026-11-13T08:06:09","slug":"sungrow-powerstack-200cs-st225kwh-110kw-2h-alternative","status":"publish","type":"post","link":"https:\/\/www.solidess.com\/fr\/sungrow-powerstack-200cs-st225kwh-110kw-2h-alternative\/","title":{"rendered":"Sungrow PowerStack 200CS vs MegSolid ESSA0100B-0215 : comparaison de BESS C&amp;I de 215 kWh"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"8426\" class=\"elementor elementor-8426\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-bf4793c e-con-full auto-article-root e-flex e-con e-parent\" data-id=\"bf4793c\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-caa9b14f auto-p elementor-widget elementor-widget-heading\" data-id=\"caa9b14f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Les EPC commerciaux qui \u00e9valuent le Sungrow PowerStack 200CS (code mod\u00e8le ST225kWh-110kW-2h) comparent souvent des armoires ext\u00e9rieures de 200 kWh lorsqu'ils dimensionnent des installations industrielles d'\u00e9cr\u00eatement de pointe et de secours.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2ff874b1 auto-p elementor-widget elementor-widget-heading\" data-id=\"2ff874b1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Cette analyse s'appuie sur notre liste de contr\u00f4le de dimensionnement du site dans <strong><a href=\"https:\/\/www.solidess.com\/fr\/comment-selectionner-un-systeme-de-stockage-denergie-par-batterie-bess-exterieur-de-100-kw-215-kwh-pour-un-site-commercial-et-industriel-ci\/\" target=\"_blank\" style=\"color:#61ce70\">Comment choisir un syst\u00e8me de stockage d'\u00e9nergie par batterie (BESS) ext\u00e9rieur de 100 kW \/ 215 kWh pour un site C&amp;I<\/a><\/strong>.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2677ca0c auto-p elementor-widget elementor-widget-heading\" data-id=\"2677ca0c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">En compl\u00e9ment de notre guide sur les plus grandes capacit\u00e9s dans <strong><a href=\"https:\/\/www.solidess.com\/fr\/alternatives-au-sungrow-powerstack-systeme-de-stockage-par-batterie-de-257-a-261-kwh-ci\/\" target=\"_blank\" style=\"color:#61ce70\">Alternatives au Sungrow PowerStack : comparaison des syst\u00e8mes de stockage C&amp;I de 257 \u00e0 261 kWh<\/a><\/strong>, nous comparons le ST225kWh-110kW-2h (110 kW \/ 229 kWh) au MegSolid ESSA0100B-0215 (100 kW \/ 215,04 kWh).<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0f1b38c5 auto-p elementor-widget elementor-widget-heading\" data-id=\"0f1b38c5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Lorsque les entrepreneurs recherchent une alternative au Sungrow PowerStack 200CS ou un BESS refroidi par air de 215 kWh, ils doivent comparer la topologie de refroidissement, l'isolement galvanique, les entr\u00e9es MPPT solaires et les limites de courant \u00e0 basse tension.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-541ac7f0 auto-p elementor-widget elementor-widget-heading\" data-id=\"541ac7f0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Dans notre <strong><a href=\"https:\/\/www.solidess.com\/fr\/piles\/stockage-denergie-ci\/\" target=\"_blank\" style=\"color:#61ce70\">Syst\u00e8mes de stockage d'\u00e9nergie commerciaux et industriels MegSolid<\/a><\/strong> gamme, trois mod\u00e8les couvrent le segment commercial de 100 kW \u00e0 500 kW :<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4ec395cf elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"4ec395cf\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">ESSA0100B-0215 (BESS ext\u00e9rieur de 100 kW \/ 215 kWh) : 100 kW CA \/ 215,04 kWh nominaux (1P240S 3,2 V \/ 280 Ah LFP standard, 672 V \u00e0 850 V CC), refroidissement intelligent par air, transformateur d'isolation int\u00e9gr\u00e9, entr\u00e9e MPPT photovolta\u00efque, \u2265 5 000 cycles (configuration LFP standard de 280 Ah)<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Energon 261 (armoire C&amp;I refroidie par liquide) : 125 kVA CA \/ 261,24 kWh nominaux (1P260S 3,2 V \/ 314 Ah LFP, 832 V nominaux, 676 V \u00e0 936 V CC), refroidissement liquide (de -20 \u00b0C \u00e0 +55 \u00b0C), 1 300 \u00d7 1 350 \u00d7 2 200 mm (base de 1,76 m\u00b2)<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">ESSC0500B-1075 (conteneur de 500 kW \/ 1,0752 MWh) : conteneur refroidi par air de 20 pieds int\u00e9gr\u00e9 en usine, correspondant \u00e0 la capacit\u00e9 de 500 kW \/ 1 075,20 kWh de cinq armoires ESSA0100B-0215<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-bf843b7e auto-image elementor-widget elementor-widget-image\" data-id=\"bf843b7e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"1536\" height=\"864\" src=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/powerstack-200cs-vs-essa-key-points-overview-1536x864.webp\" class=\"attachment-1536x1536 size-1536x1536 wp-image-8423\" alt=\"Six points de comparaison couvrant l&#039;\u00e9nergie nominale de la batterie, l&#039;isolement du transformateur, les options MPPT solaires, la limite de courant continu \u00e0 672 V, la puissance nominale CA et l&#039;empreinte au sol de l&#039;armoire.\" srcset=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/powerstack-200cs-vs-essa-key-points-overview-1536x864.webp 1536w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/powerstack-200cs-vs-essa-key-points-overview-300x169.webp 300w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/powerstack-200cs-vs-essa-key-points-overview-1024x576.webp 1024w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/powerstack-200cs-vs-essa-key-points-overview-768x432.webp 768w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/powerstack-200cs-vs-essa-key-points-overview-18x10.webp 18w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/powerstack-200cs-vs-essa-key-points-overview-600x338.webp 600w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/powerstack-200cs-vs-essa-key-points-overview.webp 2048w\" sizes=\"(max-width: 1536px) 100vw, 1536px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-16a4dd1f auto-h2 elementor-widget elementor-widget-heading\" data-id=\"16a4dd1f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Comparaison des fiches techniques : Sungrow PowerStack 200CS (ST225kWh-110kW-2h) vs MegSolid ESSA0100B-0215<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ad35baf9 auto-p elementor-widget elementor-widget-heading\" data-id=\"ad35baf9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">L'\u00e9valuation d'une alternative au ST225kWh-110kW-2h commence par la v\u00e9rification c\u00f4te \u00e0 c\u00f4te des param\u00e8tres \u00e9lectriques, thermiques, de protection incendie et m\u00e9caniques publi\u00e9s.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f5f0f256 auto-p elementor-widget elementor-widget-heading\" data-id=\"f5f0f256\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Selon la fiche technique officielle du ST225kWh-110kW-2h de Sungrow, l'\u00e9nergie nominale de la batterie est de 229 kWh, issue d'une cha\u00eene 256S1P de cellules LFP de 3,2 V \/ 280 Ah (256 \u00d7 3,2 V \u00d7 280 Ah = 229,38 kWh), tandis que 225 kWh d\u00e9signe la classe du mod\u00e8le.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-627dc798 auto-p elementor-widget elementor-widget-heading\" data-id=\"627dc798\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">En revanche, le <strong><a href=\"https:\/\/www.solidess.com\/fr\/product\/systeme-de-stockage-denergie-en-armoire-exterieure\/\" target=\"_blank\" style=\"color:#61ce70\">Syst\u00e8me de stockage d'\u00e9nergie en armoire ext\u00e9rieure MegSolid ESSA0100B-0215<\/a><\/strong> associe une cha\u00eene 1P240S de cellules LFP de 3,2 V \/ 280 Ah (240 \u00d7 3,2 V \u00d7 280 Ah = 215,04 kWh) \u00e0 un PCS de 100 kW, un transformateur d'isolation et des entr\u00e9es MPPT.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-984f2ed3 auto-table elementor-widget elementor-widget-text-editor\" data-id=\"984f2ed3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"cea-table-wrap\"><table><thead><tr><th>Param\u00e8tre de sp\u00e9cification<\/th><th>Sungrow PowerStack 200CS (fiche technique ST225kWh-110kW-2h)<\/th><th>MegSolid ESSA0100B-0215 (100 kW \/ 215,04 kWh)<\/th><th>Notes d'ing\u00e9nierie et d'int\u00e9gration<\/th><\/tr><\/thead><tbody><tr><td>Code mod\u00e8le du syst\u00e8me<\/td><td>ST225kWh-110kW-2h (PowerStack 200CS)<\/td><td>ESSA0100B-0215<\/td><td>Les deux conviennent \u00e0 l'\u00e9cr\u00eatement de pointe commercial et \u00e0 l'alimentation de secours d'environ 2 heures<\/td><\/tr><tr><td>\u00c9nergie nominale \/ assign\u00e9e<\/td><td>229 kWh nominaux (d\u00e9signation de mod\u00e8le 225 kWh)<\/td><td>215,04 kWh nominaux<\/td><td>256S1P (229,38 kWh) vs 1P240S (215,04 kWh) : calcul de la cha\u00eene<\/td><\/tr><tr><td>Puissance de sortie CA assign\u00e9e<\/td><td>110 kW<\/td><td>100 kW<\/td><td>Une puissance active de 100 kW simplifie le dimensionnement \u00e0 100 kW \/ 500 kW<\/td><\/tr><tr><td>Rapport puissance\/\u00e9nergie nominal<\/td><td>110 \/ 229 = 0,480 kW\/kWh (~2,08 h nominaux)<\/td><td>100 \/ 215,04 = 0,465 kW\/kWh (2,15 h nominaux)<\/td><td>Taux de batterie officiel de l'ESSA0100B-0215 : 0,5C \u00e0 25 \u00b0C<\/td><\/tr><tr><td>RTE du syst\u00e8me<\/td><td>90 % (publi\u00e9 sur la fiche technique Sungrow)<\/td><td>Non confirm\u00e9 \u00e0 une limite CA-CA identique sur la fiche publique ; \u00e0 confirmer par projet<\/td><td>Ne pas substituer le rendement de cr\u00eate du PCS ou le rendement maximal du syst\u00e8me au RTE CA-CA<\/td><\/tr><tr><td>Rendement maximal du PCS<\/td><td>98.5%<\/td><td>\u00c0 confirmer \u00e0 partir de la sp\u00e9cification contr\u00f4l\u00e9e du syst\u00e8me complet<\/td><td>V\u00e9rifier les courbes de conversion \u00e0 pleine charge et \u00e0 charge partielle pendant la conception<\/td><\/tr><tr><td>Type et configuration des cellules<\/td><td>3,2 V \/ 280 Ah LFP, 256S1P<\/td><td>Configuration standard : 3,2 V \/ 280 Ah LFP, 1P240S<\/td><td>L'int\u00e9gration de batteries \u00e0 l'\u00e9tat solide sp\u00e9cifique au projet n\u00e9cessite une nomenclature approuv\u00e9e<\/td><\/tr><tr><td>Fen\u00eatre de tension en courant continu<\/td><td>691,2 V \u00e0 934,4 V CC (819,2 V nominal)<\/td><td>672,0 V \u00e0 850,0 V CC (768,0 V nominal)<\/td><td>Une cha\u00eene unique en s\u00e9rie (1P) \u00e9limine les courants de cha\u00eenes parall\u00e8les \u00e0 l'int\u00e9rieur de l'armoire<\/td><\/tr><tr><td>Tension du r\u00e9seau CA et isolement<\/td><td>400 Vca (340 V \u00e0 440 V), 50\/60 Hz<\/td><td>400 Vca (320 V \u00e0 460 V), 3W+N+PE, transformateur d'isolation int\u00e9gr\u00e9<\/td><td>L'ESSA0100B-0215 assure l'isolement galvanique \u00e0 l'int\u00e9rieur de l'armoire<\/td><\/tr><tr><td>Entr\u00e9e MPPT solaire int\u00e9gr\u00e9e<\/td><td>Couplage CA via des onduleurs photovolta\u00efques externes<\/td><td>Entr\u00e9e MPPT photovolta\u00efque int\u00e9gr\u00e9e (jusqu'\u00e0 1 000 V CC ; options de s\u00e9rie 120 \/ 180 \/ 240 kW)<\/td><td>Confirmer l'option de puissance MPPT photovolta\u00efque s\u00e9lectionn\u00e9e sur le bon de commande<\/td><\/tr><tr><td>Gestion thermique et plage de temp\u00e9rature ambiante<\/td><td>Refroidissement liquide intelligent, de -30 \u00b0C \u00e0 +50 \u00b0C (d\u00e9classement au-dessus de 45 \u00b0C), diff\u00e9rence de temp\u00e9rature des cellules \u2264 2,5 \u00b0C<\/td><td>Refroidissement par air intelligent \u00e0 temp\u00e9rature contr\u00f4l\u00e9e, de 0 \u00b0C \u00e0 +45 \u00b0C<\/td><td>Choisir l'Energon 261 (de -20 \u00b0C \u00e0 +55 \u00b0C) si le refroidissement liquide est n\u00e9cessaire<\/td><\/tr><tr><td>Dur\u00e9e de vie en cycles publi\u00e9e<\/td><td>Se r\u00e9f\u00e9rer aux conditions de garantie du projet<\/td><td>\u2265 5 000 cycles (configuration LFP standard de 280 Ah)<\/td><td>Demander les courbes garanties de r\u00e9tention du SoH pour la mod\u00e9lisation du LCOS du projet<\/td><\/tr><tr><td>Protection incendie<\/td><td>D\u00e9tecteur de gaz combustible, d\u00e9tecteur de fum\u00e9e, d\u00e9tecteur de chaleur\/temp\u00e9rature, alarme sonore et visuelle, suppression d'incendie par a\u00e9rosol, syst\u00e8me de sprinklers\/d\u00e9luge \u00e0 eau et FK-5-1-12 en option<\/td><td>A\u00e9rosols \/ Novec 1230 (FK-5-1-12)<\/td><td>V\u00e9rifier la configuration de suppression et les r\u00e8gles locales du code incendie de l'AHJ<\/td><\/tr><tr><td>Enveloppe, protection et corrosion<\/td><td>IP55, anticorrosion C5 par d\u00e9faut (C3 en option)<\/td><td>IP54<\/td><td>V\u00e9rifier la classe de corrosion c\u00f4ti\u00e8re ou industrielle avant l'installation<\/td><\/tr><tr><td>Dimensions et poids<\/td><td>1 150 \u00d7 2 450 \u00d7 1 610 mm (L \u00d7 H \u00d7 P) \/ 1 150 \u00d7 1 610 \u00d7 2 450 mm (L \u00d7 P \u00d7 H), 3 100 kg<\/td><td>2 450 \u00d7 1 550 \u00d7 2 400 mm (L \u00d7 P \u00d7 H), 2 800 kg<\/td><td>Surface au sol de l'\u00e9quipement : 1,85 m\u00b2 contre 3,80 m\u00b2 (voir les notes d'implantation ci-dessous)<\/td><\/tr><tr><td>Altitude maximale et communication<\/td><td>\u2264 3 000 m ; Ethernet, Modbus TCP, iSolarCloud<\/td><td>\u2264 3 000 m ; RS485, TCP\/IP<\/td><td>Confirmer les tableaux de protocoles et les cartes de registres EMS avant la mise en service<\/td><\/tr><\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-74c1703b auto-image elementor-widget elementor-widget-image\" data-id=\"74c1703b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"1536\" height=\"864\" src=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/st225-vs-essa0100b-0215-datasheet-comparison-1536x864.webp\" class=\"attachment-1536x1536 size-1536x1536 wp-image-8424\" alt=\"Sp\u00e9cifications des fiches techniques Sungrow ST225 et MegSolid ESSA c\u00f4te \u00e0 c\u00f4te, montrant la puissance CA assign\u00e9e, l&#039;\u00e9nergie de la batterie, les plages de tension CC, le refroidissement et la protection contre les infiltrations.\" srcset=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/st225-vs-essa0100b-0215-datasheet-comparison-1536x864.webp 1536w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/st225-vs-essa0100b-0215-datasheet-comparison-300x169.webp 300w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/st225-vs-essa0100b-0215-datasheet-comparison-1024x576.webp 1024w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/st225-vs-essa0100b-0215-datasheet-comparison-768x432.webp 768w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/st225-vs-essa0100b-0215-datasheet-comparison-18x10.webp 18w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/st225-vs-essa0100b-0215-datasheet-comparison-600x338.webp 600w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/st225-vs-essa0100b-0215-datasheet-comparison.webp 2048w\" sizes=\"(max-width: 1536px) 100vw, 1536px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8d5d6353 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"8d5d6353\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">BESS de 100 kW vs 110 kW : limites de puissance active, contr\u00f4le d'exportation et raccordement au r\u00e9seau<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-99bb10b7 auto-p elementor-widget elementor-widget-heading\" data-id=\"99bb10b7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Comparer le ST225kWh-110kW-2h (110 kW) \u00e0 l'ESSA0100B-0215 (100 kW) exige de distinguer les normes techniques du r\u00e9seau, les limites d'exportation au point de connexion commun (PCC) impos\u00e9es par le gestionnaire de r\u00e9seau de distribution (DNO) et la capacit\u00e9 du transformateur d'usine.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-59ee4d04 auto-h3 elementor-widget elementor-widget-heading\" data-id=\"59ee4d04\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">1. Distinguer les normes du r\u00e9seau des plafonds d'exportation au PCC<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0d6264ac auto-p elementor-widget elementor-widget-heading\" data-id=\"0d6264ac\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Ni 100 kW ni 500 kW ne constituent un seuil universel d'approbation acc\u00e9l\u00e9r\u00e9e dans toutes les juridictions :<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-723b52af elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"723b52af\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Allemagne (VDE-AR-N 4105:2026-03) : s'applique au stockage raccord\u00e9 en parall\u00e8le au r\u00e9seau basse tension m\u00eame sans exportation, couvrant les r\u00e8gles g\u00e9n\u00e9rales en dessous de 135 kW de puissance install\u00e9e cumul\u00e9e et les cas sp\u00e9cifiques de 135 kW \u00e0 500 kW avec une injection convenue \u2264 270 kW.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Royaume-Uni (EREC G98\/G99) : les armoires de stockage commerciales triphas\u00e9es de 100 kW ou 110 kW rel\u00e8vent de l'EREC G99 plut\u00f4t que du G98, et la limitation des exportations G100 exige une protection contre les d\u00e9fauts ainsi que l'acceptation du DNO.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Plafonds de 100 kW et 500 kW propres au site : lorsqu'un tarif du r\u00e9seau ou un accord sur le d\u00e9part (feeder) limite la puissance active \u00e0 100 kW (1 unit\u00e9) ou \u00e0 500 kW (5 unit\u00e9s), une unit\u00e9 de 110 kW (550 kW pour 5 unit\u00e9s) n\u00e9cessite une limitation logicielle, alors que l'ESSA0100B-0215 s'y conforme naturellement.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Contr\u00f4le au niveau du PCC pour les groupes de 500 kW : m\u00eame avec cinq armoires de 100 kW (5 \u00d7 100 kW = 500 kW), l'application d'un plafond d'exportation de 500 kW au PCC n\u00e9cessite un contr\u00f4le de la puissance au niveau du PCC plut\u00f4t que de s'appuyer uniquement sur les valeurs de la plaque signal\u00e9tique de l'onduleur.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Dimensionnement du transformateur 630 kVA (500 \/ 0,90 = 555,56 kVA \u00e0 un FP de 0,90) : un transformateur de 630 kVA peut convenir pour un raccordement BESS de 500 kW, sous r\u00e9serve de la charge de l'installation existante, du facteur de puissance, des besoins en puissance r\u00e9active, de la charge thermique et de l'\u00e9valuation de la puissance inverse.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d605b3a1 auto-h3 elementor-widget elementor-widget-heading\" data-id=\"d605b3a1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">2. Fen\u00eatre de tension CC (672 V \u00e0 850 V) et contraintes de courant \u00e0 0,5C<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-28cb4e27 auto-p elementor-widget elementor-widget-heading\" data-id=\"28cb4e27\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">\u00c0 100 kW CA et 215,04 kWh d'\u00e9nergie nominale CC, l'ESSA0100B-0215 pr\u00e9sente un rapport de 0,465 kW\/kWh, tandis que la cha\u00eene de batterie 1P240S de 280 Ah est sp\u00e9cifi\u00e9e \u00e0 un taux de 0,5C (140,0 A) \u00e0 25 \u00b0C.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2e4abb41 auto-table elementor-widget elementor-widget-text-editor\" data-id=\"2e4abb41\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"cea-table-wrap\"><table><thead><tr><th>Point de fonctionnement CC<\/th><th>Tension de la cha\u00eene de batterie<\/th><th>Courant CC pour une charge CC de 100 kW (avant les pertes du PCS)<\/th><th>Taux de C \u00e9quivalent (base 280 Ah)<\/th><th>\u00c9valuation technique par rapport \u00e0 la limite de 0,5C (140 A)<\/th><\/tr><\/thead><tbody><tr><td>Fen\u00eatre CC sup\u00e9rieure<\/td><td>850,0 V<\/td><td>100 000 \/ 850,0 = 117,6 A<\/td><td>0,420C<\/td><td>Dans la limite de 140,0 A (0,5C) de la batterie<\/td><\/tr><tr><td>Tension nominale en courant continu<\/td><td>768,0 V<\/td><td>100 000 \/ 768,0 = 130,2 A<\/td><td>0,465C<\/td><td>Dans la limite de 140,0 A (0,5C) de la batterie avant les pertes du PCS<\/td><\/tr><tr><td>Coupure CC inf\u00e9rieure<\/td><td>672,0 V<\/td><td>100 000 \/ 672,0 = 148,8 A<\/td><td>0,531C<\/td><td>D\u00e9passe 140,0 A (0,5C) ; 672 V \u00d7 140 A = 94,08 kW de puissance CC maximale<\/td><\/tr><\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0bdb8bd7 auto-p elementor-widget elementor-widget-heading\" data-id=\"0bdb8bd7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">\u00c0 la limite inf\u00e9rieure de tension CC de 672,0 V et \u00e0 140,0 A (0,5C), la puissance CC maximale de la batterie est de 672,0 V \u00d7 140,0 A = 94,08 kW avant les pertes du PCS et la conversion du transformateur.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-cc1ab319 auto-p elementor-widget elementor-widget-heading\" data-id=\"cc1ab319\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">La puissance totale de 100 kW CA sur l'ensemble de la fen\u00eatre de tension CC doit \u00eatre v\u00e9rifi\u00e9e par rapport \u00e0 la limite de courant de la batterie, au rendement du PCS et \u00e0 la courbe de d\u00e9classement en basse tension.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-90e3475a auto-p elementor-widget elementor-widget-heading\" data-id=\"90e3475a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">La puissance nominale de 100 kW CA ne garantit pas une puissance constante \u00e0 pleine charge \u00e0 672 V CC.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b5f2fcef auto-p elementor-widget elementor-widget-heading\" data-id=\"b5f2fcef\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Demandez la fiche de sp\u00e9cifications contr\u00f4l\u00e9e, la courbe de capacit\u00e9 PQ et le sch\u00e9ma unifilaire pour l'ESSA0100B-0215 de 100 kW \/ 215,04 kWh.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8b34b19c elementor-tablet-align-center elementor-align-center auto-cta elementor-widget elementor-widget-button\" data-id=\"8b34b19c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"#elementor-action%3Aaction%3Dpopup%3Aopen%26settings%3DeyJpZCI6Ijk0OCIsInRvZ2dsZSI6ZmFsc2V9\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Obtenir la fiche technique de l'ESSA, la courbe PQ et le sch\u00e9ma unifilaire<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c0b087a4 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"c0b087a4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Chimie des cellules, isolation int\u00e9gr\u00e9e du transformateur et architecture solaire MPPT<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ead20a4f auto-p elementor-widget elementor-widget-heading\" data-id=\"ead20a4f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Les \u00e9quipes achats qui comparent le Sungrow PowerStack 200CS \u00e0 l'ESSA0100B-0215 doivent v\u00e9rifier quatre points essentiels avant la signature du contrat.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5f74c6ae auto-h3 elementor-widget elementor-widget-heading\" data-id=\"5f74c6ae\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">1. Configuration standard 280 Ah LFP vs options de batteries \u00e0 l'\u00e9tat solide sp\u00e9cifiques au projet<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c733a221 auto-p elementor-widget elementor-widget-heading\" data-id=\"c733a221\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Configuration standard : cellules LFP de 280 Ah. L'int\u00e9gration de batteries \u00e0 l'\u00e9tat solide sp\u00e9cifique au projet peut \u00eatre disponible sous r\u00e9serve d'une nomenclature (BOM) approuv\u00e9e, d'une fiche technique de cellule contr\u00f4l\u00e9e et de sp\u00e9cifications syst\u00e8me r\u00e9vis\u00e9es.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-468ec073 elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"468ec073\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Topologie \u00e0 cha\u00eene unique intra-armoire : les ST225kWh-110kW-2h (256S1P) et ESSA0100B-0215 (1P240S) utilisent tous deux une seule cha\u00eene s\u00e9rie (1P), ce qui \u00e9limine les courants de circulation entre cha\u00eenes de batterie parall\u00e8les \u00e0 l'int\u00e9rieur de l'armoire.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Fonctionnement en parall\u00e8le de plusieurs armoires : lorsque plusieurs armoires fonctionnent en parall\u00e8le au niveau de l'installation, les ing\u00e9nieurs doivent toujours dimensionner le partage du courant c\u00f4t\u00e9 CA, l'\u00e9quilibrage des imp\u00e9dances du d\u00e9part (feeder), la coordination des protections et le contr\u00f4le EMS.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Limite de dur\u00e9e de vie en cycles : la note de \u2265 5 000 cycles s'applique uniquement \u00e0 la configuration standard 280 Ah LFP ; les options personnalis\u00e9es dans le cadre de notre programme <strong><a href=\"https:\/\/www.solidess.com\/fr\/systemes-de-stockage-denergie-a-letat-solide\/\" target=\"_blank\" style=\"color:#61ce70\">Syst\u00e8mes de stockage d'\u00e9nergie hybrides \u00e0 l'\u00e9tat solide MegSolid<\/a><\/strong> n\u00e9cessitent une dur\u00e9e de vie et une confirmation de garantie distinctes.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-066e621d auto-h3 elementor-widget elementor-widget-heading\" data-id=\"066e621d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">2. Transformateur d'isolation int\u00e9gr\u00e9 et options solaires MPPT de 120 \/ 180 \/ 240 kW<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d103579a auto-p elementor-widget elementor-widget-heading\" data-id=\"d103579a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Contrairement aux armoires de stockage \u00e0 courant alternatif qui n\u00e9cessitent des onduleurs photovolta\u00efques externes et des transformateurs externes lorsque l'isolation galvanique ou le couplage solaire en courant continu est sp\u00e9cifi\u00e9, l'ESSA0100B-0215 int\u00e8gre les deux \u00e9tages \u00e0 l'int\u00e9rieur de son armoire de 2 450 x 1 550 x 2 400 mm :<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8024e2af elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"8024e2af\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Transformateur d'isolation int\u00e9gr\u00e9 : il assure l'isolation galvanique dans l'architecture int\u00e9gr\u00e9e de conversion de puissance entre le syst\u00e8me de conversion c\u00f4t\u00e9 batterie et l'interface de distribution de l'installation en 400 V CA. Les performances de commutation doivent \u00eatre confirm\u00e9es \u00e0 partir de la sp\u00e9cification contr\u00f4l\u00e9e du syst\u00e8me complet.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Entr\u00e9e solaire MPPT int\u00e9gr\u00e9e : accepte les cha\u00eenes photovolta\u00efques de toiture jusqu'\u00e0 1 000 V CC, avec des options de puissance PV s\u00e9lectionnables de 120 kW, 180 kW ou 240 kW (options de configuration \u00e0 la commande, et non des valeurs cumulables).<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Empreinte au sol vs am\u00e9nagement du site : l'int\u00e9gration du transformateur et de l'\u00e9tage MPPT donne \u00e0 l'ESSA0100B-0215 une surface au sol de 3,80 m\u00b2 (contre 1,85 m\u00b2 pour le ST225kWh-110kW-2h, soit +105 %), bien que la surface totale de la dalle d\u00e9pende \u00e9galement des all\u00e9es de maintenance, du d\u00e9battement de la porte, de l'acc\u00e8s \u00e0 la grue et de l'espacement coupe-feu.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7d9b1708 auto-h3 elementor-widget elementor-widget-heading\" data-id=\"7d9b1708\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">3. Interfaces de communication RS485 et TCP\/IP<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9ed3b1ea auto-p elementor-widget elementor-widget-heading\" data-id=\"9ed3b1ea\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">L'ESSA0100B-0215 fournit des interfaces de communication RS485 et TCP\/IP. Confirmez les protocoles pris en charge, les tables de registres, les autorisations de contr\u00f4le et les exigences d'int\u00e9gration du syst\u00e8me EMS avant la mise en service.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-dfd1fd99 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"dfd1fd99\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Quand sp\u00e9cifier l'Energon 261 (\u00e0 refroidissement liquide) ou l'ESSC0500B-1075 (conteneur de 1 MWh)<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7bf20dc6 auto-p elementor-widget elementor-widget-heading\" data-id=\"7bf20dc6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Pour les projets n\u00e9cessitant un refroidissement liquide (de -20 \u00b0C \u00e0 +55 \u00b0C), une capacit\u00e9 de cellule de 314 Ah ou une surface au sol de 1,76 m\u00b2 au lieu d'un BESS refroidi par air de 215 kWh, voir <strong><a href=\"https:\/\/www.solidess.com\/fr\/comment-choisir-entre-un-stockage-par-batterie-commercial-bess-de-215-kwh-et-de-261-kwh\/\" target=\"_blank\" style=\"color:#61ce70\">Comment choisir un stockage de batteries commercial : BESS de 215 kWh ou 261 kWh<\/a><\/strong>.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1b484e19 auto-table elementor-widget elementor-widget-text-editor\" data-id=\"1b484e19\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"cea-table-wrap\"><table><thead><tr><th>Option d'installation de 1 MWh<\/th><th>Nombre d'unit\u00e9s et mod\u00e8le<\/th><th>Puissance CA totale (kW vs kVA)<\/th><th>\u00c9nergie nominale \/ assign\u00e9e<\/th><th>Refroidissement et notes d'architecture<\/th><\/tr><\/thead><tbody><tr><td>Groupe de 5 armoires refroidies par air<\/td><td>5 x ESSA0100B-0215<\/td><td>500 kW de puissance active<\/td><td>1 075,20 kWh<\/td><td>Refroidi par air (0 \u00b0C \u00e0 +45 \u00b0C), transformateur d'isolation int\u00e9gr\u00e9 + MPPT<\/td><\/tr><tr><td>Groupe de 4 armoires \u00e0 refroidissement liquide<\/td><td>4 x <strong><a href=\"https:\/\/www.solidess.com\/fr\/product\/stockage-denergie-solide-liquide-megasolide\/\" target=\"_blank\" style=\"color:#61ce70\">Energon 261 (BESS C&amp;I \u00e0 refroidissement liquide)<\/a><\/strong><\/td><td>500 kVA de puissance apparente (450 kW \u00e0 un FP de 0,9 ; 500 kW \u00e0 un FP de 1,0)<\/td><td>1 044,96 kWh<\/td><td>Refroidissement liquide (de -20 \u00b0C \u00e0 +55 \u00b0C), capacit\u00e9 de cellule de 314 Ah, protection incendie \u00e0 eau<\/td><\/tr><tr><td>Conteneur unique de 20 pieds<\/td><td>1 x <strong><a href=\"https:\/\/www.solidess.com\/fr\/product\/systeme-de-stockage-denergie-conteneurise\/\" target=\"_blank\" style=\"color:#61ce70\">MegSolid ESSC0500B-1075 (BESS en conteneur)<\/a><\/strong><\/td><td>500 kW de puissance active<\/td><td>1 075,20 kWh<\/td><td>Conteneur ISO de 20 pieds (6 058 x 2 438 x 2 896 mm, 21 000 kg), transformateur int\u00e9gr\u00e9<\/td><\/tr><\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d18d9bda auto-image elementor-widget elementor-widget-image\" data-id=\"d18d9bda\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"1536\" height=\"864\" src=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/three-ways-to-1mwh-essa-energon-container-1536x864.webp\" class=\"attachment-1536x1536 size-1536x1536 wp-image-8425\" alt=\"Trois configurations MegSolid de 1 MWh comparant cinq armoires ESSA de 500 kW, quatre armoires Energon 261 de 500 kVA et un conteneur ESSC0500B-1075 de 500 kW.\" srcset=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/three-ways-to-1mwh-essa-energon-container-1536x864.webp 1536w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/three-ways-to-1mwh-essa-energon-container-300x169.webp 300w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/three-ways-to-1mwh-essa-energon-container-1024x576.webp 1024w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/three-ways-to-1mwh-essa-energon-container-768x432.webp 768w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/three-ways-to-1mwh-essa-energon-container-18x10.webp 18w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/three-ways-to-1mwh-essa-energon-container-600x338.webp 600w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/three-ways-to-1mwh-essa-energon-container.webp 2048w\" sizes=\"(max-width: 1536px) 100vw, 1536px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-191d3a7d auto-h2 elementor-widget elementor-widget-heading\" data-id=\"191d3a7d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Conclusion : concentrez votre projet C&amp;I de la classe 200 kWh sur les sp\u00e9cifications v\u00e9rifi\u00e9es de l'armoire<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8775251d auto-p elementor-widget elementor-widget-heading\" data-id=\"8775251d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Le choix entre le Sungrow PowerStack 200CS (ST225kWh-110kW-2h), le MegSolid ESSA0100B-0215 refroidi par air (100 kW \/ 215,04 kWh) et l'Energon 261 \u00e0 refroidissement liquide (125 kVA \/ 261,24 kWh) d\u00e9pend de la temp\u00e9rature ambiante, de l'isolation galvanique, du couplage photovolta\u00efque et des limites de puissance au PCC.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2a746a45 auto-p elementor-widget elementor-widget-heading\" data-id=\"2a746a45\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Si vous comparez \u00e9galement d'autres syst\u00e8mes commerciaux de la classe 215 kWh, consultez notre analyse technique dans <strong><a href=\"https:\/\/www.solidess.com\/fr\/luna2000-215-alternatives-au-2s10-huawei-vs-megsolid\/\" target=\"_blank\" style=\"color:#61ce70\">Huawei LUNA2000-215-2S10 Alternatives : comparaison des architectures de BESS C&amp;I<\/a><\/strong>.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f6582b1d auto-p elementor-widget elementor-widget-heading\" data-id=\"f6582b1d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Contactez notre \u00e9quipe d'ing\u00e9nierie commerciale pour les sp\u00e9cifications contr\u00f4l\u00e9es des ESSA0100B-0215, Energon 261 et ESSC0500B-1075, les courbes de d\u00e9classement en basse tension et un devis de projet.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d623cef6 elementor-tablet-align-center elementor-align-center auto-cta elementor-widget elementor-widget-button\" data-id=\"d623cef6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"#elementor-action%3Aaction%3Dpopup%3Aopen%26settings%3DeyJpZCI6Ijk0OCIsInRvZ2dsZSI6ZmFsc2V9\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Obtenir les sp\u00e9cifications contr\u00f4l\u00e9es, les tables de registres et un devis de projet<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-8050c2c9 auto-faq e-flex e-con-boxed e-con e-child\" data-id=\"8050c2c9\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-2c94c2e0 elementor-widget elementor-widget-heading\" data-id=\"2c94c2e0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">FAQ<\/h2>\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-9c198135 e-con-full e-flex e-con e-child\" data-id=\"9c198135\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-8ce29277 elementor-widget elementor-widget-n-accordion\" data-id=\"8ce29277\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;default_state&quot;:&quot;all_collapsed&quot;,&quot;max_items_expended&quot;:&quot;one&quot;,&quot;n_accordion_animation_duration&quot;:{&quot;unit&quot;:&quot;ms&quot;,&quot;size&quot;:400,&quot;sizes&quot;:[]}}\" data-widget_type=\"nested-accordion.default\">\n\t\t\t\t\t\t\t<div class=\"e-n-accordion\" aria-label=\"Accord\u00e9on. Ouvrez les liens \u00e0 l&#039;aide de la touche Entr\u00e9e ou de la barre d&#039;espace, fermez-les avec la touche \u00c9chap et naviguez \u00e0 l&#039;aide des touches fl\u00e9ch\u00e9es.\">\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2360\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"1\" tabindex=\"0\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2360\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> La version standard de l'ESSA0100B-0215 est-elle livr\u00e9e avec des cellules LFP de 280 Ah ou des cellules \u00e0 l'\u00e9tat solide ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2360\" class=\"elementor-element elementor-element-d911efff e-con-full e-flex e-con e-child\" data-id=\"d911efff\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2360\" class=\"elementor-element elementor-element-76109b44 e-con-full e-flex e-con e-child\" data-id=\"76109b44\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-972355bd elementor-widget elementor-widget-heading\" data-id=\"972355bd\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Configuration standard : cellules LFP de 280 Ah. L'int\u00e9gration de batteries \u00e0 l'\u00e9tat solide sp\u00e9cifique au projet peut \u00eatre disponible sous r\u00e9serve d'une nomenclature (BOM) approuv\u00e9e, d'une fiche technique de cellule contr\u00f4l\u00e9e et de sp\u00e9cifications syst\u00e8me r\u00e9vis\u00e9es.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2361\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"2\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2361\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Une topologie \u00e0 cha\u00eene unique 1P240S \u00e9limine-t-elle tous les courants de circulation dans une installation \u00e0 plusieurs armoires ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2361\" class=\"elementor-element elementor-element-0e3e0f2e e-con-full e-flex e-con e-child\" data-id=\"0e3e0f2e\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2361\" class=\"elementor-element elementor-element-4babb125 e-con-full e-flex e-con e-child\" data-id=\"4babb125\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ff37ba5e elementor-widget elementor-widget-heading\" data-id=\"ff37ba5e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Non ; si la topologie 1P240S \u00e9limine les courants de circulation entre cha\u00eenes de batterie parall\u00e8les \u00e0 l'int\u00e9rieur de chaque armoire, la mise en parall\u00e8le de plusieurs armoires sur un bus 400 V CA n\u00e9cessite toujours un contr\u00f4le du partage du courant c\u00f4t\u00e9 CA, un \u00e9quilibrage des imp\u00e9dances et une protection coordonn\u00e9e.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2362\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"3\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2362\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Quelles sont les options de puissance d'entr\u00e9e PV MPPT s\u00e9lectionnables sur l'ESSA0100B-0215 ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2362\" class=\"elementor-element elementor-element-a5f12678 e-con-full e-flex e-con e-child\" data-id=\"a5f12678\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2362\" class=\"elementor-element elementor-element-e9020cfe e-con-full e-flex e-con e-child\" data-id=\"e9020cfe\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-dbe0be74 elementor-widget elementor-widget-heading\" data-id=\"dbe0be74\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">La fiche technique de la s\u00e9rie ESSA0100B-0215 \u00e9num\u00e8re les options de puissance d'entr\u00e9e PV MPPT s\u00e9lectionnables de 120 kW, 180 kW et 240 kW (jusqu'\u00e0 1 000 V CC maximum) ; les acheteurs doivent sp\u00e9cifier l'option choisie lors de la commande.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2363\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"4\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2363\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Quel r\u00f4le joue le transformateur d'isolation int\u00e9gr\u00e9 dans l'ESSA0100B-0215 ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2363\" class=\"elementor-element elementor-element-92b00234 e-con-full e-flex e-con e-child\" data-id=\"92b00234\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2363\" class=\"elementor-element elementor-element-0ef49902 e-con-full e-flex e-con e-child\" data-id=\"0ef49902\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c2430b71 elementor-widget elementor-widget-heading\" data-id=\"c2430b71\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Transformateur d'isolation int\u00e9gr\u00e9 : il assure l'isolation galvanique dans l'architecture int\u00e9gr\u00e9e de conversion de puissance entre le syst\u00e8me de conversion c\u00f4t\u00e9 batterie et l'interface de distribution de l'installation en 400 V CA. Les performances de commutation doivent \u00eatre confirm\u00e9es \u00e0 partir de la sp\u00e9cification contr\u00f4l\u00e9e du syst\u00e8me complet.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2364\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"5\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2364\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Comment les syst\u00e8mes de protection contre les incendies du Sungrow PowerStack 200CS et de l'ESSA0100B-0215 se comparent-ils ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2364\" class=\"elementor-element elementor-element-2b76da46 e-con-full e-flex e-con e-child\" data-id=\"2b76da46\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2364\" class=\"elementor-element elementor-element-ff4e8fdd e-con-full e-flex e-con e-child\" data-id=\"ff4e8fdd\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c635fa46 elementor-widget elementor-widget-heading\" data-id=\"c635fa46\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">La fiche technique du ST225kWh-110kW-2h de Sungrow sp\u00e9cifie des d\u00e9tecteurs de gaz combustibles, de fum\u00e9e et de chaleur, des alarmes sonores et visuelles, la suppression par a\u00e9rosols, l'arrosage par eau \/ d\u00e9luge et la configuration optionnelle FK-5-1-12 ; l'ESSA0100B-0215 sp\u00e9cifie l'a\u00e9rosol ou le Novec 1230 (FK-5-1-12) \u00e0 la commande.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2365\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"6\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2365\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Si mon site n\u00e9cessite un refroidissement liquide (de -20 \u00b0C \u00e0 +55 \u00b0C) et une capacit\u00e9 de cellule de 314 Ah, quelle armoire MegSolid dois-je choisir ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2365\" class=\"elementor-element elementor-element-4bc992f2 e-con-full e-flex e-con e-child\" data-id=\"4bc992f2\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2365\" class=\"elementor-element elementor-element-c50e82a2 e-con-full e-flex e-con e-child\" data-id=\"c50e82a2\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-25bda88c elementor-widget elementor-widget-heading\" data-id=\"25bda88c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Choisissez l'Energon 261 \u00e0 refroidissement liquide (125 kVA \/ 261,24 kWh, 1P260S 314 Ah LFP, emprise au sol de 1,76 m\u00b2, protection incendie \u00e0 eau et agent propre Novec 1230). Quatre unit\u00e9s Energon 261 fournissent une puissance apparente de 500 kVA (450 kW de puissance active \u00e0 un FP de 0,9, ou 500 kW \u00e0 un FP de 1,0), tandis que cinq unit\u00e9s ESSA0100B-0215 fournissent une puissance active de 500 kW.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2366\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"7\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2366\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> En quoi les exigences relatives \u00e0 la surface au sol de l'\u00e9quipement et \u00e0 la dalle en b\u00e9ton diff\u00e8rent-elles entre les deux mod\u00e8les ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2366\" class=\"elementor-element elementor-element-02136aea e-con-full e-flex e-con e-child\" data-id=\"02136aea\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2366\" class=\"elementor-element elementor-element-e0ee4058 e-con-full e-flex e-con e-child\" data-id=\"e0ee4058\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-27dcef7d elementor-widget elementor-widget-heading\" data-id=\"27dcef7d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">L'int\u00e9gration du transformateur d'isolation et de l'\u00e9tage MPPT donne \u00e0 l'ESSA0100B-0215 une surface au sol de 3,80 m\u00b2 contre 1,85 m\u00b2 pour le ST225kWh-110kW-2h, bien que la surface totale de la dalle en b\u00e9ton d\u00e9pende \u00e9galement du d\u00e9battement des portes, des all\u00e9es de maintenance et de l'espacement coupe-feu.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2367\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"8\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2367\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Comment la norme allemande VDE-AR-N 4105:2026-03 s'applique-t-elle lors du choix d'un BESS de 100 kW ou de 110 kW ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2367\" class=\"elementor-element elementor-element-0bbcc25f e-con-full e-flex e-con e-child\" data-id=\"0bbcc25f\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2367\" class=\"elementor-element elementor-element-e97aabe2 e-con-full e-flex e-con e-child\" data-id=\"e97aabe2\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c41efc2f elementor-widget elementor-widget-heading\" data-id=\"c41efc2f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">La norme VDE-AR-N 4105:2026-03 r\u00e9git le stockage raccord\u00e9 en parall\u00e8le au r\u00e9seau basse tension en Allemagne (m\u00eame sans exportation), couvrant les seuils g\u00e9n\u00e9raux en dessous de 135 kW de puissance install\u00e9e cumul\u00e9e et les r\u00e8gles sp\u00e9cifiques de 135 kW \u00e0 500 kW lorsque l'injection convenue est \u2264 270 kW.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2368\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"9\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2368\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Le choix d'une armoire de 100 kW dispense-t-il un projet C&amp;I britannique des \u00e9tudes de r\u00e9seau EREC G99 ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2368\" class=\"elementor-element elementor-element-1f2c8a68 e-con-full e-flex e-con e-child\" data-id=\"1f2c8a68\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2368\" class=\"elementor-element elementor-element-1f70b22c e-con-full e-flex e-con e-child\" data-id=\"1f70b22c\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-7a8a93ff elementor-widget elementor-widget-heading\" data-id=\"7a8a93ff\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Non ; les unit\u00e9s BESS commerciales triphas\u00e9es de 100 kW ou 110 kW rel\u00e8vent de l'EREC G99, et tout dispositif de limitation des exportations actif G100 au PCC exige une protection contre les d\u00e9fauts et l'acceptation formelle du DNO.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2369\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"10\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2369\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Quelle armoire convient aux d\u00e9parts commerciaux \u00e0 haute temp\u00e9rature ambiante en Australie, en Afrique du Sud ou au Moyen-Orient ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2369\" class=\"elementor-element elementor-element-eba8f2ca e-con-full e-flex e-con e-child\" data-id=\"eba8f2ca\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2369\" class=\"elementor-element elementor-element-217a09f0 e-con-full e-flex e-con e-child\" data-id=\"217a09f0\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-d7523d86 elementor-widget elementor-widget-heading\" data-id=\"d7523d86\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Pour les zones temp\u00e9r\u00e9es (0 \u00b0C \u00e0 +45 \u00b0C) n\u00e9cessitant un couplage direct en courant continu du photovolta\u00efque et une isolation par transformateur, choisissez l'ESSA0100B-0215. Pour les temp\u00e9ratures ambiantes sup\u00e9rieures \u00e0 45 \u00b0C (jusqu'\u00e0 +55 \u00b0C avec d\u00e9classement au-dessus de 45 \u00b0C) ou les environnements difficiles, sp\u00e9cifiez l'Energon 261.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Comparez le Sungrow PowerStack 200CS (110 kW \/ 229 kWh) au MegSolid ESSA0100B-0215 (100 kW \/ 215,04 kWh), y compris les sp\u00e9cifications des cellules LFP, le refroidissement, l'int\u00e9gration photovolta\u00efque et les exigences de raccordement au r\u00e9seau.<\/p>","protected":false},"author":4,"featured_media":8422,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"_joinchat":[],"footnotes":""},"categories":[1,712],"tags":[639,1024,184,1025,1023,1026],"class_list":["post-8426","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-bess","category-bess-product-comparisons","tag-100kw-215kwh-outdoor-bess","tag-215kwh-air-cooled-bess","tag-essa0100b-0215","tag-st225kwh-110kw-2h-alternative","tag-sungrow-powerstack-200cs","tag-sungrow-powerstack-200cs-alternative"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/posts\/8426","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/comments?post=8426"}],"version-history":[{"count":7,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/posts\/8426\/revisions"}],"predecessor-version":[{"id":8450,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/posts\/8426\/revisions\/8450"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/media\/8422"}],"wp:attachment":[{"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/media?parent=8426"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/categories?post=8426"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/tags?post=8426"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}