{"id":8489,"date":"2026-11-16T09:49:21","date_gmt":"2026-11-16T01:49:21","guid":{"rendered":"https:\/\/www.solidess.com\/?p=8489"},"modified":"2026-11-16T09:49:21","modified_gmt":"2026-11-16T01:49:21","slug":"sungrow-central-inverters-sc5000ud-vs-modular-bess-pcs","status":"publish","type":"post","link":"https:\/\/www.solidess.com\/fr\/sungrow-central-inverters-sc5000ud-vs-modular-bess-pcs\/","title":{"rendered":"Onduleurs centraux Sungrow vs PCS modulaires BESS"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"8489\" class=\"elementor elementor-8489\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-bf4793c e-con-full auto-article-root e-flex e-con e-parent\" data-id=\"bf4793c\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-78c080e5 auto-p elementor-widget elementor-widget-heading\" data-id=\"78c080e5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Choisissez le PCS \u00e0 grande \u00e9chelle en fonction de la plage de tension continue de la batterie, de la tension alternative du convertisseur et du transformateur requis au point de raccordement au r\u00e9seau. Le MegSolid 5000INTL int\u00e8gre un PCS 690 Vac pour le stockage \u00e0 grande \u00e9chelle, tandis que les PMA et MEGA-TS desservent diff\u00e9rents sites en 400 Vac. La gamme Sungrow 1+X est destin\u00e9e au PV ; comparez le SC5000UD-MV lorsque vous avez besoin d'une conversion bidirectionnelle de batterie.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-55388bb8 elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"55388bb8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Distinguez les onduleurs photovolta\u00efques des PCS bidirectionnels.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">V\u00e9rifiez la fen\u00eatre compl\u00e8te de tension continue de la batterie et la conception de l'isolation.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Comparez le courant AC, la puissance MVA du transformateur et les options de service.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-61f7d296 auto-image elementor-widget elementor-widget-image\" data-id=\"61f7d296\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"1536\" height=\"864\" src=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/central-vs-modular-pcs-key-points-overview-1536x864.webp\" class=\"attachment-1536x1536 size-1536x1536 wp-image-8486\" alt=\"Six points de v\u00e9rification pour les PCS central et modulaire, notamment la compatibilit\u00e9 en courant continu, le courant alternatif et la capacit\u00e9 du transformateur\" srcset=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/central-vs-modular-pcs-key-points-overview-1536x864.webp 1536w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/central-vs-modular-pcs-key-points-overview-300x169.webp 300w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/central-vs-modular-pcs-key-points-overview-1024x576.webp 1024w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/central-vs-modular-pcs-key-points-overview-768x432.webp 768w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/central-vs-modular-pcs-key-points-overview-2048x1152.webp 2048w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/central-vs-modular-pcs-key-points-overview-18x10.webp 18w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/central-vs-modular-pcs-key-points-overview-600x338.webp 600w\" sizes=\"(max-width: 1536px) 100vw, 1536px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-48e42da5 auto-p elementor-widget elementor-widget-heading\" data-id=\"48e42da5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Dans la gamme utility de Sungrow, les SG3300UD, SG3500UD-MV, 1+X (1,1 MW \u00e0 8,8 MW) et 1+X 2.0 (800 kW \u00e0 9,6 MW) sont des onduleurs photovolta\u00efques, tandis que les SC2750UD-MV (2 750 kVA) et SC5000UD-MV (5 000 kVA \u00e0 40 \u00b0C) sont des PCS BESS bidirectionnels.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-13288374 auto-p elementor-widget elementor-widget-heading\" data-id=\"13288374\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Selon la topologie des branches de circuit, la s\u00e9lectivit\u00e9 de protection et la logique des contacteurs du BMS, le raccordement de plusieurs cha\u00eenes de batteries sur les entr\u00e9es CC partag\u00e9es d'un PCS central peut introduire un d\u00e9s\u00e9quilibre d'imp\u00e9dance entre les cha\u00eenes et des contraintes sur la fen\u00eatre de tension, tout en n\u00e9cessitant des tranch\u00e9es pour les c\u00e2bles CC pos\u00e9s sur site entre les conteneurs et les skids.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-093b468f auto-p elementor-widget elementor-widget-heading\" data-id=\"093b468f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">S'appuyant sur notre <strong><a href=\"https:\/\/www.solidess.com\/fr\/guide-de-selection-des-onduleurs-de-stockage-denergie-integres-avec-transformateur-par-rapport-aux-onduleurs-modulaires-pour-pcs\/\" target=\"_blank\" style=\"color:#61ce70\">Onduleurs de stockage d'\u00e9nergie \u00e0 transformateur int\u00e9gr\u00e9 ou modulaires : guide de s\u00e9lection d'un PCS C&amp;I<\/a><\/strong>, ce guide compare les PCS centralis\u00e9s aux MegSolid 5000INTL (2 700 kW \/ 5 015,9 kWh, 450 kW \u00d7 6), MEGA-TS (30\u2013500 kW) et PMA080\u2013PMA0125 (80\u2013125 kW) modulaires.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1f0332cc auto-h2 elementor-widget elementor-widget-heading\" data-id=\"1f0332cc\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">SC5000UD-MV vs PCS modulaires<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f6582070 auto-p elementor-widget elementor-widget-heading\" data-id=\"f6582070\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\"><strong>\u00c0 retenir :<\/strong> Adapter le mat\u00e9riel PCS \u00e0 la tension de raccordement au r\u00e9seau permet d'abord de distinguer les centrales 690 Vac \/ MV (o\u00f9 les conteneurs int\u00e9gr\u00e9s \u00e9liminent les tranch\u00e9es CC entre les cha\u00eenes) des installations C&amp;I en 400 Vac (o\u00f9 les armoires modulaires en rack ou int\u00e9gr\u00e9es au transformateur s'installent directement dans les locaux \u00e9lectriques existants).<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8362e1e6 auto-p elementor-widget elementor-widget-heading\" data-id=\"8362e1e6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Toutes les sp\u00e9cifications MegSolid des tableaux 1a et 1b refl\u00e8tent les valeurs publi\u00e9es des fiches techniques pour <strong><a href=\"https:\/\/www.solidess.com\/fr\/product\/systeme-de-stockage-denergie-conteneurise-megasolid-5000intl\/\" target=\"_blank\" style=\"color:#61ce70\">BESS conteneuris\u00e9 MegSolid 5000INTL 2,7 MW \/ 5 MWh<\/a><\/strong>, <strong><a href=\"https:\/\/www.solidess.com\/fr\/product\/systeme-de-conversion-denergie-megsolid\/\" target=\"_blank\" style=\"color:#61ce70\">Syst\u00e8mes de conversion de puissance MegSolid MEGA-TS<\/a><\/strong>, et <strong><a href=\"https:\/\/www.solidess.com\/fr\/product\/onduleur-de-stockage-denergie-megasolid\/\" target=\"_blank\" style=\"color:#61ce70\">Onduleurs de stockage d'\u00e9nergie modulaires MegSolid PMA<\/a><\/strong> dans une comparaison entre le Sungrow SC5000UD-MV et les PCS modulaires.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a1184ebb auto-h3 elementor-widget elementor-widget-heading\" data-id=\"a1184ebb\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">PCS utility et onduleurs PV<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-183b6610 auto-table elementor-widget elementor-widget-text-editor\" data-id=\"183b6610\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"cea-table-wrap\"><table><thead><tr><th>Caract\u00e9ristique<\/th><th>SC5000UD-MV V15<\/th><th>5000INTL<\/th><\/tr><\/thead><tbody><tr><td>\u00c9quipement<\/td><td>PCS central + skid MT<\/td><td>BESS int\u00e9gr\u00e9<\/td><\/tr><tr><td>Puissance nominale<\/td><td>5 000 kVA \u00e0 40 \u00b0C<\/td><td>2 700 kW<\/td><\/tr><tr><td>Fen\u00eatre CC (V)<\/td><td>1 300\u20131 500<\/td><td>1 123,2\u20131 497,6<\/td><\/tr><tr><td>Port CA du convertisseur<\/td><td>900 V CA<\/td><td>690 V CA<\/td><\/tr><tr><td>Conversion<\/td><td>2 entr\u00e9es CC \/ branches<\/td><td>6 \u00e9tages de 450 kW<\/td><\/tr><\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-503eef8d auto-p elementor-widget elementor-widget-heading\" data-id=\"503eef8d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Le SC5000UD-MV V15 affiche 5 500 kVA \u00e0 30 \u00b0C ; le SC2750UD-MV est \u00e9valu\u00e9 \u00e0 2 750 kVA. Les 1+X et 1+X 2.0 de Sungrow sont des onduleurs PV avec une entr\u00e9e PV jusqu'\u00e0 1 500 Vdc, distincts de la comparaison avec les PCS bidirectionnels.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7441abf3 auto-h3 elementor-widget elementor-widget-heading\" data-id=\"7441abf3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">PCS 400 Vac pour le C&amp;I<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a0833e4d auto-table elementor-widget elementor-widget-text-editor\" data-id=\"a0833e4d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"cea-table-wrap\"><table><thead><tr><th>Mod\u00e8le<\/th><th>CA nominale<\/th><th>Courant CA nominal \/ max<\/th><th>CC max kW \/ A<\/th><\/tr><\/thead><tbody><tr><td>PMA080<\/td><td>80 kW<\/td><td>115 \/ 138 A<\/td><td>96 kW \/ \u00b1150 A<\/td><\/tr><tr><td>PMA0105<\/td><td>105 kW<\/td><td>150 \/ 180 A<\/td><td>126 kW \/ \u00b1195 A<\/td><\/tr><tr><td>PMA0125<\/td><td>125 kW<\/td><td>180 \/ 216 A<\/td><td>150 kW \/ \u00b1230 A<\/td><\/tr><\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-20af10a6 auto-p elementor-widget elementor-widget-heading\" data-id=\"20af10a6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\"><strong>PMA:<\/strong> V\u00e9rifiez la fen\u00eatre de tension continue propre au c\u00e2blage : 615\u2013950 Vdc pour 3W+PE ou 650\u2013950 Vdc pour 3W+N+PE. Les modules 19 pouces mesurent 483 \u00d7 680 mm, avec une hauteur de 174 mm (4U) ou 220 mm (5U).<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-271aae16 auto-p elementor-widget elementor-widget-heading\" data-id=\"271aae16\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\"><strong>MEGA-TS:<\/strong> Armoires int\u00e9gr\u00e9es au transformateur de 30, 50, 100, 150, 250 et 500 kW. Le 500TS affiche 550 kVA maximum et jusqu'\u00e0 97,5 % d'efficacit\u00e9 ; confirmez la puissance CC et le courant maximum par code de commande.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-dfc0dfc7 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"dfc0dfc7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Fen\u00eatres CC et dimensionnement des \u00e9tages<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ccf75589 auto-p elementor-widget elementor-widget-heading\" data-id=\"ccf75589\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\"><strong>\u00c0 retenir :<\/strong> Lors de l'\u00e9valuation des PCS centralis\u00e9s par rapport aux PCS en rack pour les BESS \u00e0 grande \u00e9chelle, la colocalisation de six \u00e9tages de conversion de 450 kW avec un seul banc de batteries 5000INTL 12P416S dans un seul conteneur 5000INTL \u00e9limine les tranch\u00e9es CC externes entre les skids tout en adaptant le convertisseur directement \u00e0 la fen\u00eatre de tension de la batterie de 1 123,2\u20131 497,6 V CC.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-41de4537 auto-h3 elementor-widget elementor-widget-heading\" data-id=\"41de4537\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">V\u00e9rifiez le bus CC commun<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5e5be234 auto-p elementor-widget elementor-widget-heading\" data-id=\"5e5be234\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Douze cha\u00eenes de batteries 416S1P compos\u00e9es de cellules 3,2 V \/ 314 Ah donnent \u00e0 chaque cha\u00eene <strong>416 \u00d7 3.2 V = 1,331.2 V<\/strong> de tension nominale et une capacit\u00e9 de 417,9968 kWh (5 015,96 kWh au total).<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-788e3cb4 auto-p elementor-widget elementor-widget-heading\" data-id=\"788e3cb4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Lorsque plusieurs cha\u00eenes sont connect\u00e9es en parall\u00e8le sur une branche d'entr\u00e9e CC commune, toutes les cha\u00eenes parall\u00e8les sur ce bus partagent la m\u00eame tension aux bornes Vbus :<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0011c9d7 elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"0011c9d7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>V\u00e9rification de la compatibilit\u00e9 de la fen\u00eatre de tension :<\/strong> Le SC5000UD-MV V15 n\u00e9cessite 1 300\u20131 500 V CC (port 900 Vac), tandis que le banc 12P416S du 5000INTL fonctionne \u00e0 1 123,2\u20131 497,6 V CC (690 Vac) ; les associer sur toute la fen\u00eatre n\u00e9cessite une conversion CC\/CC, un redimensionnement des cha\u00eenes ou des limites de fen\u00eatre.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>Formule du courant circulant entre cha\u00eenes :<\/strong> Pour deux cha\u00eenes parall\u00e8les avec des tensions en circuit ouvert Vocv1 et Vocv2 et des r\u00e9sistances CC internes R1 et R2, le courant transitoire de repos est <strong>Icirculating = (Vocv1 \u2212 Vocv2) \u00f7 (R1 + R2 + Rbus)<\/strong>.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>DCIR th\u00e9orique de la cha\u00eene :<\/strong> En utilisant le DCIR nominal de cellule de 0,4 mOhm des cellules SHS180-314 dans <strong><a href=\"https:\/\/www.solidess.com\/fr\/systemes-de-stockage-denergie-a-letat-solide\/\" target=\"_blank\" style=\"color:#61ce70\">Syst\u00e8mes de stockage d'\u00e9nergie \u00e0 l'\u00e9tat solide MegSolid<\/a><\/strong>, une cha\u00eene 416S a un DCIR th\u00e9orique des seules cellules de <strong>416 \u00d7 0.4 m\u03a9 = 166.4 m\u03a9<\/strong>.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>Calcul illustratif du courant de boucle :<\/strong> En supposant un \u00e9cart de tension en circuit ouvert ind\u00e9pendant de 6,0 V sur une boucle \u00e0 deux cha\u00eenes (r\u00e9sistance de 200 mOhm par cha\u00eene, 0,4 Ohm au total), le courant d'\u00e9galisation initial est <strong>6.0 V \u00f7 0.4 \u03a9 = 15.0 A<\/strong>.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>Logique de contr\u00f4le de coupure :<\/strong> Lorsque la cha\u00eene la plus faible approche de sa limite de tension, le fait que le syst\u00e8me r\u00e9duise sa puissance, ouvre les contacteurs de branche ou s'arr\u00eate d\u00e9pend de la strat\u00e9gie de contr\u00f4le du BMS et du PCS (en distinguant les fen\u00eatres CC du syst\u00e8me des coupures franches des cellules).<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>Base de la capacit\u00e9 inaccessible :<\/strong> Si la logique de contr\u00f4le arr\u00eate la d\u00e9charge du banc lorsqu'une cha\u00eene atteint la coupure alors que les 11 autres cha\u00eenes (417,9968 kWh chacune) d\u00e9tiennent une \u00e9nergie illustrative de 5 %\u20138 %, 229,90\u2013367,84 kWh restent inutilis\u00e9s jusqu'au r\u00e9\u00e9quilibrage.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-717d4b3a auto-image elementor-widget elementor-widget-image\" data-id=\"717d4b3a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"1536\" height=\"864\" src=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/shared-dc-bus-window-mismatch-circulating-current-1536x864.webp\" class=\"attachment-1536x1536 size-1536x1536 wp-image-8487\" alt=\"Calcul illustratif des cha\u00eenes, fen\u00eatres de tension CC, courant d&#039;\u00e9galisation et \u00e9nergie bloqu\u00e9e sur un bus CC commun\" srcset=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/shared-dc-bus-window-mismatch-circulating-current-1536x864.webp 1536w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/shared-dc-bus-window-mismatch-circulating-current-300x169.webp 300w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/shared-dc-bus-window-mismatch-circulating-current-1024x576.webp 1024w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/shared-dc-bus-window-mismatch-circulating-current-768x432.webp 768w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/shared-dc-bus-window-mismatch-circulating-current-18x10.webp 18w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/shared-dc-bus-window-mismatch-circulating-current-600x338.webp 600w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/shared-dc-bus-window-mismatch-circulating-current.webp 2048w\" sizes=\"(max-width: 1536px) 100vw, 1536px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ba701ad0 auto-h3 elementor-widget elementor-widget-heading\" data-id=\"ba701ad0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Comment les six \u00e9tages du PCS s'int\u00e8grent<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ccc0bcec auto-p elementor-widget elementor-widget-heading\" data-id=\"ccc0bcec\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Le conteneur 5000INTL de MegSolid pr\u00e9-int\u00e8gre son banc de batteries refroidi par liquide 12P416S (5 015,9 kWh, code de type de batterie SHS180-314) et 2 700 kW de conversion CA dans une seule enceinte IP55 de 20 pieds (6 058 \u00d7 2 438 \u00d7 2 896 mm), \u00e9liminant les passages de c\u00e2bles d'alimentation CC pos\u00e9s sur site entre les skids de batteries et d'onduleurs s\u00e9par\u00e9s :<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-13f1b16c elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"13f1b16c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>Six \u00e9tages de conversion de 450 kW :<\/strong> Plut\u00f4t que de s'appuyer sur un seul \u00e9tage de conversion, le 5000INTL r\u00e9partit sa puissance CA nominale de 2 700 kW sur six \u00e9tages de conversion de 450 kW (<strong>450 kW \u00d7 6 = 2,700 kW<\/strong>) \u00e0 690 Vac.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>D\u00e9faut d'\u00e9tage et maintenance s\u00e9lective :<\/strong> Cinq \u00e9tages actifs au total <strong>de capacit\u00e9 nominale de 2 250 kW<\/strong>. La poursuite de l'exploitation apr\u00e8s un d\u00e9faut d'\u00e9tage d\u00e9pend de la conception approuv\u00e9e d'isolation et de contr\u00f4le. Lors de la mise en service, MegSolid configure la topologie d'isolation CC\/CA, la s\u00e9lectivit\u00e9 de protection des branches, le routage de l'alimentation auxiliaire et la logique de contr\u00f4le EMS en fonction des objectifs de disponibilit\u00e9 du projet, afin que les \u00e9quipes de service puissent isoler proprement un \u00e9tage affect\u00e9 tout en maintenant une exploitation coordonn\u00e9e du site.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>Coordination du SLD personnalis\u00e9 et des contacteurs :<\/strong> Parce que le 5000INTL associe 12 cha\u00eenes (12P416S) \u00e0 six \u00e9tages de 450 kW, les ing\u00e9nieurs d'application MegSolid fournissent des sch\u00e9mas unifilaires contr\u00f4l\u00e9s (SLD) pendant la conception du projet afin que les EPC puissent v\u00e9rifier le regroupement des barres omnibus de cha\u00eene \u00e0 \u00e9tage et la s\u00e9lectivit\u00e9 des contacteurs de branche.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>Option PMA d\u00e9di\u00e9e 400 Vac 1 cha\u00eene\u20131 PCS :<\/strong> Pour les projets commerciaux et industriels en 400 Vac con\u00e7us autour de racks de batteries d\u00e9di\u00e9s 615\u2013950 Vdc (3W+PE) ou 650\u2013950 Vdc (3W+N+PE), les modules sans transformateur PMA080, PMA0105 et PMA0125 attribuent un canal PCS ind\u00e9pendant par cha\u00eene pour \u00e9liminer la mise en parall\u00e8le du bus CC partag\u00e9, et s'associent facilement \u00e0 un transformateur d'isolation externe ou \u00e0 une armoire MEGA-TS chaque fois qu'une isolation galvanique est sp\u00e9cifi\u00e9e.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>Marge de puissance active et r\u00e9active :<\/strong> Fournir 2,50 MW de puissance active plus 1,00 MVAr de soutien r\u00e9actif au r\u00e9seau n\u00e9cessite <strong>S = \u221a(2.50\u00b2 + 1.00\u00b2) = 2.693 MVA<\/strong> (PF = 0,928) ; notre \u00e9quipe d'ing\u00e9nierie fournit des courbes de capacit\u00e9 P-Q de projet pour v\u00e9rifier la puissance continue en kVA sur les temp\u00e9ratures ambiantes du site.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-101c3a97 auto-p elementor-widget elementor-widget-heading\" data-id=\"101c3a97\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Besoin de courbes de capacit\u00e9 P-Q, de sch\u00e9mas de c\u00e2blage de cha\u00eene \u00e0 PCS ou de tarifs d'usine pour votre projet de stockage \u00e0 grande \u00e9chelle ou C&amp;I ? Parlez directement \u00e0 nos ing\u00e9nieurs en \u00e9lectronique de puissance.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-339e22a3 elementor-tablet-align-center elementor-align-center auto-cta elementor-widget elementor-widget-button\" data-id=\"339e22a3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"#elementor-action%3Aaction%3Dpopup%3Aopen%26settings%3DeyJpZCI6Ijk0OCIsInRvZ2dsZSI6ZmFsc2V9\" target=\"_blank\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Demander les sch\u00e9mas unifilaires du PCS<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-75a4a631 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"75a4a631\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">O\u00f9 le 1+X s'int\u00e8gre dans un projet BESS<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ae8a0f9d auto-p elementor-widget elementor-widget-heading\" data-id=\"ae8a0f9d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\"><strong>\u00c0 retenir :<\/strong> Les EPC solaires qui recherchent une alternative \u00e0 un onduleur modulaire Sungrow 1+x lors de leur expansion dans le stockage par batterie peuvent \u00e9viter la maintenance lourde des grues et les skids de transformateurs externes en s\u00e9lectionnant des modules PMA mont\u00e9s en rack de 48\u201350 kg ou des armoires MEGA-TS int\u00e9gr\u00e9es au transformateur pour les sites en 400 Vac.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-353f6cf0 auto-h3 elementor-widget elementor-widget-heading\" data-id=\"353f6cf0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Onduleurs PV et PCS de batterie<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e9e6ac2c auto-p elementor-widget elementor-widget-heading\" data-id=\"e9e6ac2c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Les 1+X de Sungrow (unit\u00e9s de 1,1 MW jusqu'\u00e0 8,8 MW) et 1+X 2.0 (unit\u00e9s de 800 kW jusqu'\u00e0 9,6 MW) sont des onduleurs solaires PV, tandis que les SC2750UD-MV et SC5000UD-MV V15 (2 entr\u00e9es CC \/ 2 branches) sont des plateformes PCS BESS :<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7f3ca0e0 elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"7f3ca0e0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>R\u00f4le de l'\u00e9quipement et granularit\u00e9 :<\/strong> La premi\u00e8re g\u00e9n\u00e9ration de 1+X utilise des blocs PV de 1,1 MW et le 1+X 2.0 utilise des blocs PV de 800 kW, tandis que la conversion BESS n\u00e9cessite des \u00e9tages PCS de batterie bidirectionnels adapt\u00e9s \u00e0 la tension de la cha\u00eene de batteries et au taux C (C-rate).<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>Tranch\u00e9es CC sur les skids PCS externes :<\/strong> L'association de conteneurs de batteries externes \u00e0 un skid PCS central s\u00e9par\u00e9 n\u00e9cessite de creuser des tranch\u00e9es souterraines pour les c\u00e2bles d'alimentation CC pos\u00e9s sur site et les faisceaux de communication entre l'enceinte de la batterie et le skid PCS.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>Port du convertisseur basse tension vs tableaux de distribution \u00e0 quatre fils 400 Vac :<\/strong> Le SC5000UD-MV V15 prend en charge des charges d\u00e9s\u00e9quilibr\u00e9es hors r\u00e9seau \u00e0 100 %. Son interface c\u00f4t\u00e9 convertisseur triphas\u00e9e 900 Vac se connecte \u00e0 l'enroulement basse tension d'un transformateur \u00e9l\u00e9vateur MT, plut\u00f4t que directement \u00e0 un tableau de distribution industriel \u00e0 quatre fils 400 Vac.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-55c6ad58 auto-h3 elementor-widget elementor-widget-heading\" data-id=\"55c6ad58\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Options PCS MegSolid<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6bf41181 auto-p elementor-widget elementor-widget-heading\" data-id=\"6bf41181\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Pour le stockage de batteries bidirectionnel, MegSolid propose une conversion modulaire sur trois niveaux distincts de tension, de poids et d'enceinte :<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f42df32a elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"f42df32a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>Niveau 1 (modules en rack PMA080\u2013PMA0125, 80\u2013125 kW) :<\/strong> Pesant seulement 48 kg (c\u00e2blage arri\u00e8re) ou 50 kg (c\u00e2blage avant) dans un ch\u00e2ssis 19 pouces 4U (483 x 680 x 174 mm) ou 5U (483 x 680 x 220 mm) (puissance IP20 \/ commande IP6X), chaque module se glisse dans des racks int\u00e9rieurs standard sans grue, avec une efficacit\u00e9 maximale de 98,7 % et une commutation charge\/d\u00e9charge &lt; 20 ms.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>Fen\u00eatre de c\u00e2blage PMA et limites de courant :<\/strong> La plage de fonctionnement CC est de 615\u2013950 Vdc (3W+PE) ou 650\u2013950 Vdc (3W+N+PE) ; les courants CC max \/ CA max sont de \u00b1150 A \/ 138 A (PMA080), \u00b1195 A \/ 180 A (PMA0105) et \u00b1230 A \/ 216 A (PMA0125).<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>Niveau 2 (armoires int\u00e9gr\u00e9es au transformateur MEGA-TS, 30\u2013500 kW) :<\/strong> Les armoires int\u00e9rieures IP21 (-30 \u00b0C \u00e0 +55 \u00b0C) int\u00e8grent un transformateur d'isolement basse fr\u00e9quence pour un raccordement direct en 400 Vac (3W+N+PE) sur un tableau de distribution industriel, sans armoire de transformateur externe, avec des plages CC de 250\u2013850 V (30 kW), 320\u2013850 V (50 kW), 420\u2013850 V (100\u2013250 kW) et 500\u2013850 V (500 kW \/ 550 kVA max).<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>Niveau 3 (armoires et conteneurs tout-en-un pour l'ext\u00e9rieur) :<\/strong> Pour un d\u00e9ploiement ext\u00e9rieur plug-and-play sans local PCS int\u00e9rieur, les EPC peuvent sp\u00e9cifier des syst\u00e8mes IP54\/IP55, notamment <strong><a href=\"https:\/\/www.solidess.com\/fr\/product\/stockage-denergie-solide-liquide-megasolide\/\" target=\"_blank\" style=\"color:#61ce70\">BESS C&amp;I MegSolid Energon 261 \u00e0 refroidissement liquide<\/a><\/strong>, <strong><a href=\"https:\/\/www.solidess.com\/fr\/product\/systeme-de-stockage-denergie-en-armoire-exterieure\/\" target=\"_blank\" style=\"color:#61ce70\">BESS en armoire ext\u00e9rieure MegSolid ESSA0100B-0215<\/a><\/strong>, ou <strong><a href=\"https:\/\/www.solidess.com\/fr\/product\/systeme-de-stockage-denergie-conteneurise\/\" target=\"_blank\" style=\"color:#61ce70\">Conteneurs MegSolid ESSC0500B-1075 et ESSC1000B-2150<\/a><\/strong>.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5e1312a9 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"5e1312a9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">690 Vac vs 400 Vac<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-54380727 auto-p elementor-widget elementor-widget-heading\" data-id=\"54380727\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\"><strong>\u00c0 retenir :<\/strong> \u00c9lever la sortie CA du conteneur jusqu'\u00e0 690 Vac dans le 5000INTL de 2,7 MW r\u00e9duit le courant de ligne CA triphas\u00e9 de 42,03 % par rapport \u00e0 un bus de 400 Vac, ce qui simplifie le cheminement des barres omnibus basse tension vers les transformateurs \u00e9l\u00e9vateurs moyenne tension de 10\u201335 kV (\u00e0 noter que le SC5000UD-MV V15 exploite son port CA de convertisseur \u00e0 900 Vac).<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f5ab7f76 auto-p elementor-widget elementor-widget-heading\" data-id=\"f5ab7f76\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Pour les comparaisons de d\u00e9ploiement de conteneurs \u00e0 l'\u00e9chelle utility avec des skids refroidis par liquide de 5 MWh, voir <strong><a href=\"https:\/\/www.solidess.com\/fr\/sungrow-st5015kwh-2500kw-2h-powertitan-alternative-5000intl\/\" target=\"_blank\" style=\"color:#61ce70\">Sungrow PowerTitan ST5015kWh-2500kW-2h vs MegSolid 5000INTL<\/a><\/strong>.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f8cd883b auto-h3 elementor-widget elementor-widget-heading\" data-id=\"f8cd883b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Courant et pertes \u00e0 2,7 MW<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-33a28b9f auto-p elementor-widget elementor-widget-heading\" data-id=\"33a28b9f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">En supposant 2 700 kW de puissance active triphas\u00e9e \u00e0 facteur de puissance unitaire (cos phi = 1,0) :<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e2e895b8 elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"e2e895b8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>Courant \u00e0 pleine charge \u00e0 400 Vac :<\/strong> <strong>I\u2084\u2080\u2080 = 2,700,000 W \u00f7 (\u221a3 \u00d7 400 V) = 3,897.11 A<\/strong> (environ 3 897 A).<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>Courant \u00e0 pleine charge \u00e0 690 Vac :<\/strong> <strong>I\u2086\u2089\u2080 = 2,700,000 W \u00f7 (\u221a3 \u00d7 690 V) = 2,259.20 A<\/strong> (environ 2 259 A).<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>R\u00e9duction du courant de ligne :<\/strong> L'exploitation \u00e0 690 Vac r\u00e9duit le courant de ligne CA de <strong>1 \u2212 (400 \u00f7 690) = 42.03%<\/strong> par rapport \u00e0 un bus de 400 Vac.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>Pertes ohmiques (r\u00e9sistance R constante uniquement) :<\/strong> Puisque <strong>Ploss = 3 \u00d7 I\u00b2 \u00d7 R<\/strong>, le maintien de la r\u00e9sistance R du conducteur constante r\u00e9duit les pertes I\u00b2R de 66,39 % (<strong>(400 \u00f7 690)\u00b2 = 0.3361<\/strong>); la r\u00e9duction de la section du conducteur modifie R et change ce ratio.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-46f9e140 auto-table elementor-widget elementor-widget-text-editor\" data-id=\"46f9e140\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"cea-table-wrap\"><table><thead><tr><th>\u00c0 2 700 kW<\/th><th>400 Vac<\/th><th>690 V CA<\/th><\/tr><\/thead><tbody><tr><td>Courant de ligne \u00e0 PF 1,0<\/td><td>3,897.1 A<\/td><td>2,259.2 A<\/td><\/tr><tr><td>Pertes I\u00b2R \u00e0 R \u00e9gal<\/td><td>100.0%<\/td><td>33.61%<\/td><\/tr><\/tbody><\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-fa2484ba auto-image elementor-widget elementor-widget-image\" data-id=\"fa2484ba\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"1536\" height=\"864\" src=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/2700kw-690vac-vs-400vac-current-loss-transformer-1536x864.webp\" class=\"attachment-1536x1536 size-1536x1536 wp-image-8488\" alt=\"Courant triphas\u00e9 \u00e0 2 700 kW sur des bus de 400 V et 690 V, avec la puissance apparente pour deux unit\u00e9s 5000INTL\" srcset=\"https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/2700kw-690vac-vs-400vac-current-loss-transformer-1536x864.webp 1536w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/2700kw-690vac-vs-400vac-current-loss-transformer-300x169.webp 300w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/2700kw-690vac-vs-400vac-current-loss-transformer-1024x576.webp 1024w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/2700kw-690vac-vs-400vac-current-loss-transformer-768x432.webp 768w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/2700kw-690vac-vs-400vac-current-loss-transformer-18x10.webp 18w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/2700kw-690vac-vs-400vac-current-loss-transformer-600x338.webp 600w, https:\/\/www.solidess.com\/wp-content\/uploads\/2026\/11\/2700kw-690vac-vs-400vac-current-loss-transformer.webp 2048w\" sizes=\"(max-width: 1536px) 100vw, 1536px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9cdd1513 auto-p elementor-widget elementor-widget-heading\" data-id=\"9cdd1513\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Pour deux unit\u00e9s de 2,7 MW, le besoin en puissance apparente \u00e0 5,4 MW est de <strong>5,40 MVA \u00e0 PF 1,0, 5,68 MVA \u00e0 PF 0,95 ou 6,00 MVA \u00e0 PF 0,90<\/strong>. Choisissez le transformateur apr\u00e8s avoir v\u00e9rifi\u00e9 chaque enroulement, l'enveloppe P\u2013Q du site et les conditions d'exploitation.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-30807bb1 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"30807bb1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Adapter le PCS au site<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c6f2a84f auto-p elementor-widget elementor-widget-heading\" data-id=\"c6f2a84f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\"><strong>\u00c0 retenir :<\/strong> Utilisez la matrice de s\u00e9lection rapide ci-dessous pour associer le point de couplage commun de votre installation (local int\u00e9rieur 400 Vac, plateforme ext\u00e9rieure 400 Vac ou poste MT 690 Vac) au mod\u00e8le exact de PCS MegSolid ou de BESS int\u00e9gr\u00e9 avant de demander les plans d'appel d'offres.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-cd9bfc73 elementor-widget-mobile__width-inherit auto-list elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"cd9bfc73\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>Racks int\u00e9rieurs 400 Vac :<\/strong> PMA080, PMA0105 ou PMA0125 (80\u2013125 kW par module ; jusqu'\u00e0 1,25 MW dans l'exemple multi-unit\u00e9s de la source). Confirmez les limites de parall\u00e9lisme et la tension CC selon le mode de c\u00e2blage.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>400 Vac avec isolation :<\/strong> MEGA0030TS \u00e0 MEGA0500TS (30\u2013500 kW). Confirmez la plage CC et les configurations parall\u00e8les approuv\u00e9es du mod\u00e8le s\u00e9lectionn\u00e9 ; la source indique jusqu'\u00e0 quatre unit\u00e9s pour le MEGA0500TS.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>Armoires ext\u00e9rieures 400 Vac :<\/strong> ESSA0100B-0215 (100 kW \/ 215,04 kWh, 3 900 kg) ou Energon 261 (125 kVA \/ 261,24 kWh). V\u00e9rifiez l'agencement et la puissance totale pour les projets multi-armoires de 100 kW \u00e0 1 MW.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>Conteneurs 400 Vac :<\/strong> ESSC0500B-1075 (500 kW, 722 A) ou ESSC1000B-2150 (1 000 kW, 1 445 A). Les deux utilisent un PCS int\u00e9gr\u00e9 et des transformateurs d'isolement.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-circle\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><strong>690 Vac vers MT :<\/strong> 5000INTL (2 700 kW \/ 5 015,9 kWh), avec six \u00e9tages de 450 kW et un conteneur IP55 refroidi par liquide. Dimensionnez le transformateur \u00e9l\u00e9vateur MT selon le service P\u2013Q du projet.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3f6231b6 auto-h2 elementor-widget elementor-widget-heading\" data-id=\"3f6231b6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">V\u00e9rifications avant de demander un devis<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7ea75ee2 auto-p elementor-widget elementor-widget-heading\" data-id=\"7ea75ee2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">\u00c9valuer les onduleurs centraux Sungrow aux c\u00f4t\u00e9s des PCS modulaires BESS alternatifs exige de v\u00e9rifier les fen\u00eatres de tension CC (par exemple 1 123,2\u20131 497,6 V contre 1 300\u20131 500 V ou 615\u2013950 V), la s\u00e9lectivit\u00e9 de la protection des branches et le dimensionnement en MVA du transformateur MT selon le facteur de puissance.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0b0610ae auto-p elementor-widget elementor-widget-heading\" data-id=\"0b0610ae\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Pour le dimensionnement du transformateur moyenne tension, le choix du groupe de couplage et la coordination de la protection, consultez <strong><a href=\"https:\/\/www.solidess.com\/fr\/integration-des-transformateurs-bess-synchronisation-du-reseau\/\" target=\"_blank\" style=\"color:#61ce70\">Int\u00e9gration des transformateurs BESS et synchronisation au r\u00e9seau<\/a><\/strong>.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b65bde37 auto-p elementor-widget elementor-widget-heading\" data-id=\"b65bde37\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Demandez les fiches techniques officielles, les courbes de capacit\u00e9 P-Q et les offres de prix pour les solutions PCS MegSolid 5000INTL (2,7 MW \/ 5 015,9 kWh), MEGA-TS (30\u2013500 kW) et PMA080\u2013PMA0125 (80\u2013125 kW).<\/p>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1cc3faaf elementor-tablet-align-center elementor-align-center auto-cta elementor-widget elementor-widget-button\" data-id=\"1cc3faaf\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"#elementor-action%3Aaction%3Dpopup%3Aopen%26settings%3DeyJpZCI6Ijk0OCIsInRvZ2dsZSI6ZmFsc2V9\" target=\"_blank\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Obtenir les fiches techniques et les tarifs du projet<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-ede49b9a auto-faq e-flex e-con-boxed e-con e-child\" data-id=\"ede49b9a\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-910b9876 elementor-widget elementor-widget-heading\" data-id=\"910b9876\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">FAQ<\/h2>\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-80a20e65 e-con-full e-flex e-con e-child\" data-id=\"80a20e65\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-f7dac8b8 elementor-widget elementor-widget-n-accordion\" data-id=\"f7dac8b8\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;default_state&quot;:&quot;all_collapsed&quot;,&quot;max_items_expended&quot;:&quot;one&quot;,&quot;n_accordion_animation_duration&quot;:{&quot;unit&quot;:&quot;ms&quot;,&quot;size&quot;:400,&quot;sizes&quot;:[]}}\" data-widget_type=\"nested-accordion.default\">\n\t\t\t\t\t\t\t<div class=\"e-n-accordion\" aria-label=\"Accord\u00e9on. Ouvrez les liens \u00e0 l&#039;aide de la touche Entr\u00e9e ou de la barre d&#039;espace, fermez-les avec la touche \u00c9chap et naviguez \u00e0 l&#039;aide des touches fl\u00e9ch\u00e9es.\">\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-4150\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"1\" tabindex=\"0\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-4150\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Comment le 5000INTL fournit-il 2 700 kW ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-4150\" class=\"elementor-element elementor-element-b012312d e-con-full e-flex e-con e-child\" data-id=\"b012312d\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-4150\" class=\"elementor-element elementor-element-2d899bc3 e-con-full e-flex e-con e-child\" data-id=\"2d899bc3\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-decf0afb elementor-widget elementor-widget-heading\" data-id=\"decf0afb\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Selon la sp\u00e9cification officielle du 5000INTL, le conteneur IP55 de 20 pieds (6 058 x 2 438 x 2 896 mm ; plage de temp\u00e9rature ambiante de fonctionnement de -30 \u00b0C \u00e0 +55 \u00b0C) fournit 2 700 kW de puissance CA nominale via six \u00e9tages de 450 kW (<strong>450 kW \u00d7 6<\/strong>) \u00e0 690 Vac. Son banc de batteries intelligent refroidi par liquide abrite une configuration 12P416S (code de type de batterie SHS180-314) totalisant 5 015,9 kWh \u00e0 1 331,2 V CC nominal (1 123,2 V \u00e0 1 497,6 V CC).<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-4151\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"2\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-4151\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Comment les six \u00e9tages sont-ils reli\u00e9s aux cha\u00eenes ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-4151\" class=\"elementor-element elementor-element-4ce04790 e-con-full e-flex e-con e-child\" data-id=\"4ce04790\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-4151\" class=\"elementor-element elementor-element-22c53ed4 e-con-full e-flex e-con e-child\" data-id=\"22c53ed4\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-3f8ea470 elementor-widget elementor-widget-heading\" data-id=\"3f8ea470\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Le 5000INTL fournit 2 700 kW de puissance CA nominale gr\u00e2ce \u00e0 six \u00e9tages de conversion de 450 kW associ\u00e9s \u00e0 son banc de batteries 12P416S (416S par cha\u00eene \u00e0 1 331,2 V nominal). Cinq \u00e9tages actifs de 450 kW assurent 2 250 kW de capacit\u00e9 nominale combin\u00e9e. Lors de l'ing\u00e9nierie du projet, MegSolid d\u00e9finit le regroupement exact des barres omnibus cha\u00eene-\u00e9tage, la s\u00e9lectivit\u00e9 de la protection des contacteurs de branche, l'alimentation auxiliaire et la logique d'isolement des d\u00e9fauts de l'EMS dans des sch\u00e9mas unifilaires contr\u00f4l\u00e9s adapt\u00e9s aux objectifs de disponibilit\u00e9 du site.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-4152\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"3\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-4152\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Quelles sont les plages de tension CC du MEGA-TS ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-4152\" class=\"elementor-element elementor-element-2aa83e16 e-con-full e-flex e-con e-child\" data-id=\"2aa83e16\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-4152\" class=\"elementor-element elementor-element-ef6b95e1 e-con-full e-flex e-con e-child\" data-id=\"ef6b95e1\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a2fdc550 elementor-widget elementor-widget-heading\" data-id=\"a2fdc550\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">La s\u00e9rie MEGA-TS de MegSolid, des PCS en armoire C&amp;I pos\u00e9s au sol, int\u00e8gre un transformateur d'isolement basse fr\u00e9quence (400 Vac, 3W+N+PE), une enceinte int\u00e9rieure IP21 et une plage de temp\u00e9rature de fonctionnement de -30 \u00b0C \u00e0 +55 \u00b0C. Les plages d'entr\u00e9e CC publi\u00e9es sont de 250\u2013850 V CC pour le MEGA0030TS (30 kW), de 320\u2013850 V CC pour le MEGA0050TS (50 kW) et de 420\u2013850 V CC pour les MEGA0100TS (100 kW), MEGA0150TS (150 kW) et MEGA0250TS (250 kW). Le MEGA0500TS (500 kW CA nominal \/ 550 kVA max en puissance apparente) fonctionne sur 500\u2013850 V CC avec une efficacit\u00e9 maximale de 97,5 %.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-4153\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"4\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-4153\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Quelles sont les caract\u00e9ristiques et dimensions du PMA ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-4153\" class=\"elementor-element elementor-element-ff0894bd e-con-full e-flex e-con e-child\" data-id=\"ff0894bd\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-4153\" class=\"elementor-element elementor-element-9880646e e-con-full e-flex e-con e-child\" data-id=\"9880646e\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-3e9de5f8 elementor-widget elementor-widget-heading\" data-id=\"3e9de5f8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Selon la fiche technique officielle du PMA, la plage de fonctionnement CC de la batterie est de 615\u2013950 Vdc (3W+PE) et de 650\u2013950 Vdc (3W+N+PE), avec une efficacit\u00e9 maximale de 98,7 % et une protection IP20 pour le compartiment de puissance \/ IP6X pour le compartiment de commande. Les dimensions sont de 483 x 680 x 174 mm (19 pouces, 4U) ou 483 x 680 x 220 mm (19 pouces, 5U), pour un poids de 48 kg (c\u00e2blage arri\u00e8re) ou 50 kg (c\u00e2blage avant). Les caract\u00e9ristiques sont de 96 kW CC max, \u00b1150 A CC max, 115 A CA nominal et 138 A CA max (PMA080) ; 126 kW, \u00b1195 A, 150 A et 180 A (PMA0105) ; et 150 kW, \u00b1230 A, 180 A et 216 A (PMA0125).<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-4154\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"5\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-4154\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Quand le 690 Vac r\u00e9duit-il les pertes I\u00b2R de 66,39 % ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-4154\" class=\"elementor-element elementor-element-0459c9ee e-con-full e-flex e-con e-child\" data-id=\"0459c9ee\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-4154\" class=\"elementor-element elementor-element-1a15c2a7 e-con-full e-flex e-con e-child\" data-id=\"1a15c2a7\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-abc35ca2 elementor-widget elementor-widget-heading\" data-id=\"abc35ca2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">\u00c0 2 700 kW et \u00e0 facteur de puissance unitaire, \u00e9lever la tension nominale de 400 Vac \u00e0 690 Vac r\u00e9duit le courant CA triphas\u00e9 de 3 897,1 A \u00e0 2 259,2 A (soit une r\u00e9duction de courant de 42,03 %). Avec la r\u00e9sistance R du conducteur (section de c\u00e2ble et longueur de parcours identiques) maintenue constante, les pertes ohmiques triphas\u00e9es varient avec le carr\u00e9 du courant, ce qui donne une r\u00e9duction des pertes de 66,39 % (<strong>(400 \u00f7 690)\u00b2 = 0.3361<\/strong>). Cette comparaison ne couvre que les pertes dans les conducteurs. \u00c0 titre de r\u00e9f\u00e9rence, le SC5000UD-MV V15 de Sungrow \u00e9l\u00e8ve la tension de son port CA de convertisseur de 900 Vac vers le transformateur MT.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-4155\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"6\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-4155\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> En quoi les chiffres d'efficacit\u00e9 publi\u00e9s diff\u00e8rent-ils ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-4155\" class=\"elementor-element elementor-element-20f78eff e-con-full e-flex e-con e-child\" data-id=\"20f78eff\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-4155\" class=\"elementor-element elementor-element-647645e0 e-con-full e-flex e-con e-child\" data-id=\"647645e0\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-5ae43f75 elementor-widget elementor-widget-heading\" data-id=\"5ae43f75\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Selon les fiches techniques publi\u00e9es de MegSolid, les modules rack PMA080 \/ PMA0105 \/ PMA0125 sans transformateur atteignent jusqu'\u00e0 98,7 % d'efficacit\u00e9 PCS maximale, et l'armoire MEGA0500TS int\u00e9gr\u00e9e au transformateur atteint jusqu'\u00e0 97,5 % d'efficacit\u00e9 PCS maximale. Au niveau du conteneur cl\u00e9 en main, la fiche technique du 5000INTL publie une sp\u00e9cification d'efficacit\u00e9 maximale de 87,5 %. V\u00e9rifiez les limites de test avant de la comparer \u00e0 l'efficacit\u00e9 PCS maximale. Mod\u00e9lisez s\u00e9par\u00e9ment les charges de refroidissement auxiliaires et le dispatch du site.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-4156\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"7\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-4156\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Le temps de commutation du PCS est-il le m\u00eame que le temps de transfert ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-4156\" class=\"elementor-element elementor-element-8c6c4990 e-con-full e-flex e-con e-child\" data-id=\"8c6c4990\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-4156\" class=\"elementor-element elementor-element-e0b85537 e-con-full e-flex e-con e-child\" data-id=\"e0b85537\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-972f44a5 elementor-widget elementor-widget-heading\" data-id=\"972f44a5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Les modules PMA080, PMA0105 et PMA0125 sans transformateur publient un temps de commutation charge\/d\u00e9charge inf\u00e9rieur \u00e0 20 ms, permettant une inversion rapide du sens de la puissance entre les commandes de charge et de d\u00e9charge. Lors de la conception de micro-r\u00e9seaux industriels ou de s\u00e9quences de transfert black-start avec des modules PMA ou des armoires MEGA-TS, les ing\u00e9nieurs d'application MegSolid coordonnent les commandes du PCS, les commutateurs STS\/transfert externes, les relais de protection et les s\u00e9quences de commande du micro-r\u00e9seau pour atteindre les objectifs de temps de transfert propres au projet.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-4157\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"8\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-4157\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Comment le courant circulant et l'\u00e9nergie inutilis\u00e9e sont-ils estim\u00e9s ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-4157\" class=\"elementor-element elementor-element-8d7beea3 e-con-full e-flex e-con e-child\" data-id=\"8d7beea3\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-4157\" class=\"elementor-element elementor-element-bc2c377c e-con-full e-flex e-con e-child\" data-id=\"bc2c377c\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-b8a52c0d elementor-widget elementor-widget-heading\" data-id=\"b8a52c0d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Les deux chiffres servent de calculs d'ing\u00e9nierie de r\u00e9f\u00e9rence reproductibles fond\u00e9s sur des hypoth\u00e8ses explicites d'imp\u00e9dance de boucle et d'\u00e9tat de charge. L'utilisation d'une DCIR de cellule autonome de 0,4 mOhm donne une r\u00e9sistance s\u00e9rie th\u00e9orique de 166,4 mOhm pour les seules cellules 416S, et la mod\u00e9lisation d'un delta ind\u00e9pendant de 6,0 V en circuit ouvert sur une boucle \u00e0 deux cha\u00eenes de 0,4 Ohm donne <strong>6.0 V \u00f7 0.4 \u03a9 = 15.0 A<\/strong>. Dans un banc de 12 cha\u00eenes o\u00f9 11 cha\u00eenes parall\u00e8les (417,9968 kWh chacune) conservent une r\u00e9serve mod\u00e9lis\u00e9e de 5 %\u20138 % non pr\u00e9lev\u00e9e lorsqu'une cha\u00eene atteint le seuil de coupure, 229,90\u2013367,84 kWh restent temporairement indisponibles en fin de cycle.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-4158\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"9\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-4158\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Quand un conteneur ESSC 400 Vac est-il le meilleur choix ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-4158\" class=\"elementor-element elementor-element-7c113433 e-con-full e-flex e-con e-child\" data-id=\"7c113433\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-4158\" class=\"elementor-element elementor-element-67b89944 e-con-full e-flex e-con e-child\" data-id=\"67b89944\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-f196690c elementor-widget elementor-widget-heading\" data-id=\"f196690c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Sp\u00e9cifiez le 5000INTL (2 700 kW \/ 5 015,9 kWh, 690 Vac, IP55 refroidi par liquide) pour les projets utility multi-m\u00e9gawatts et industriels lourds se raccordant via des transformateurs \u00e9l\u00e9vateurs 690 V vers MT. Pour les sites de 500\u20131 000 kW se raccordant directement \u00e0 un tableau de distribution 400 Vac (3W+N+PE) sans skid MT, sp\u00e9cifiez l'ESSC0500B-1075 (500 kW \/ 1 075,20 kWh, 722 A) ou l'ESSC1000B-2150 (1 000 kW \/ 2 150,40 kWh, 1 445 A) IP54 refroidis par air.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-4159\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"10\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-4159\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Quelles options PCS sont con\u00e7ues pour l'ext\u00e9rieur ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-4159\" class=\"elementor-element elementor-element-fbab0341 e-con-full e-flex e-con e-child\" data-id=\"fbab0341\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-4159\" class=\"elementor-element elementor-element-46b4f46e e-con-full e-flex e-con e-child\" data-id=\"46b4f46e\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-b098587e elementor-widget elementor-widget-heading\" data-id=\"b098587e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Les modules PMA080, PMA0105 et PMA0125 pr\u00e9sentent un compartiment de puissance IP20 et un compartiment de commande IP6X, et les armoires MEGA0030TS\u2013MEGA0500TS portent une protection IP21 adapt\u00e9e aux locaux \u00e9lectriques int\u00e9rieurs ou \u00e0 l'int\u00e9gration dans des enceintes \u00e9tanches. Pour les d\u00e9ploiements ext\u00e9rieurs sans b\u00e2timent PCS d\u00e9di\u00e9, les EPC sp\u00e9cifient des armoires tout-en-un IP54 scell\u00e9es en usine (ESSA0100B-0215 ou Energon 261), des conteneurs ESSC IP54 ou le conteneur IP55 5000INTL.<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Compare Sungrow central PCS with MegSolid 5000INTL, MEGA-TS and PMA by battery voltage window, 400 or 690 Vac interface, and transformer sizing.<\/p>","protected":false},"author":4,"featured_media":8485,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"_joinchat":[],"footnotes":""},"categories":[1,712],"tags":[516,462,296,1031,1030],"class_list":["post-8489","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-bess","category-bess-product-comparisons","tag-mega-ts","tag-megsolid-5000intl","tag-modular-pcs","tag-pma","tag-sungrow-sc5000ud-mv"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/posts\/8489","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/comments?post=8489"}],"version-history":[{"count":4,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/posts\/8489\/revisions"}],"predecessor-version":[{"id":8493,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/posts\/8489\/revisions\/8493"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/media\/8485"}],"wp:attachment":[{"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/media?parent=8489"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/categories?post=8489"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.solidess.com\/fr\/wp-json\/wp\/v2\/tags?post=8489"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}