Iifektri zaseYurophu ezihlawula iintlawulo eziphezulu zomthamo kunye namaxabiso amandla atshintshashintshayo ziyaqhubeka zibuza lo mbuzo unye: ibhetri ye-C&I ibuyisa imali engakanani na xa sele kuthathelwe ingqalelo isiphelo se-SOC, ixesha lokusabela kunye nomthamo onokusetyenziswa? Amanani okuthengisa anqabileyo ukuba ahlale xa edibana neprofayili yokulayisha yokwenene yemizuzu eli-15. Le nqaku ke ngoko iqala kwiimveliso ezimbini eziphathekayo — the ESSA0100B-0215 Ikhabhathi yangaphandle (100 kW / 215.04 kWh) kunye ne Ikhabhathi ye-Hybrid Solid-State epholisiweyo ngokuyi-liquid (125 kVA / 261.24 kWh) — kwaye ibonisa indlela imiqathango epapashiweyo eguqulela ngayo kwimbuyekezo yonyaka, apho izibalo zihlala zisilela khona, nokuba oko kusilela kubiza malini.
Iindlela Ezintathu Zexabiso Ezibalulekileyo Ngokwenene
Emva kokujonga amashumi eeprojekthi zeefektri zaseYurophu, kukho iinkalo ezintathu ezisoloko zinqumla isiphumo:
- Ukucheba incopho – yeyona lala inokuthenjwa kakhulu. Iyona ifaka isifundo se-kW esiphezulu esimisela intlawulo yomthamo.
- Arbitrage yencopho nentlambo – Incedo eluncedo, kodwa kuphela ukuba ibhetri isenamandla xa kuvela isasazo.
- Impendulo yomthamo / ukuguquguquka – ingeniso eyongezelelweyo enokubakho, kodwa kufuna ukuba inkqubo ibekhona kwaye iphendule kanye ngomzuzu xa i-aggregator ifowuna.
Ukunqanda umthamo ophezulu kuhlawula kuqala. I-Arbitrage kunye nempendulo yemfuno zongeza ixabiso kuphela xa ibhetri sele ikhusele ixesha elibalulekileyo lomthamo ophezulu kwaye igcine isipaji se-SOC esisebenzisekayo. Yiba lixa ungayihoyanga loo landelelwano, inzuzo yespredishithi ayisoze ivele kwi-invoyisi.
Iiparamitha zeMveliso ezinokusetyenziswa kuBalo lokwenene
Onke amanani angezantsi athathwe kwiinkcukacha ezisemthethweni zemveliso.
ESSA0100B-0215 Ikhabhathi yangaphandle
- Amandla aqikelelweyo: 215.04 kWh
- Amandla ombane we-AC amiselweyo: 100 kW
- Ukhuseleko: IP54
- Ukupholisa: ukupholisa komoya okukrelekrele
- Ubomi besayikili: ≥ iisayikili ezi-5,000
Iinkcukacha: Iinkcukacha ze-ESS yeKhabhathi yangaphandle
Ikhabhathi ye-Hybrid ye-Solid-State ePholisiweyo ngeLwelo
- Amandla alinganisiweyo: 261.24 kWh
- Amandla ombane we-AC alinganisiweyo: 125 kVA
- Ukhuseleko: IP54
- Ukupholisa: ukupholisa okubalulekileyo ngokwengqiqo okusebenzisa ulwelo (umahluko wobushushu lweeseli ugcinwa ungadlulanga i-±5 °C)
- Umthamo wokwenza ngokunxuseneyo: iiyunithi ezili-10
- Ukusebenza kakuhle okuphezulu kwenkqubo: 90 %
Iinombolo Zokusebenza: Oko Kwenziwa Ngokwenene NgamaKhabhinethi Amabini
Thatha umzi-mveliso waseYurophu ongumaphakathi onezindleko zomrhumo wemfuno ze-€12 / kW / ngenyanga, umahluko ophakathi kwe-€0.12 / kWh phakathi kwexesha elixakekileyo nelingaxakekanga, kunye nesidingo sokugcina isipaji se-15–20 % SOC sokulungiselela ixesha elixakekileyo elilandelayo okanye isiganeko sokuphendula kwimfuno.
215.04 kWh Ikhabhathi yangaphandle (100 kW)
Emva kokusebenza kakuhle kunye nesipaji, amandla asetyenziswayo ngesiphindaphindo ngasinye aba phakathi kwe-160–175 kWh. Ukunciphisa incopho ngama-80–100 kW ngexesha elifanelekileyo kudla ngokonga i-€10,000–€14,000 ngonyaka kwiintlawulo zokufuna. I-Arbitrage kumandla aseleyo yongeza enye i-€11,000–€12,500. Isixa esidityanisiweyo esilula sonyaka phambi kwe-O&M: €21,000–€26,000.
261.24 kWh Ikhabhathi ePholisiweyo ngeLulwelo (125 kVA)
Amandla ombane aphezulu ashiya ithuba elingakumbi emva kwesipaji esifanayo. Amandla asebenzisekayo ngomjikelo ngamnye ngokuqhelekileyo afikelela kwi-195–215 kWh. Phantsi kweemeko ezifanayo zetarif, ixabiso elidibeneyo lokunciphisa umthamo ophezulu kunye ne-arbitrage lihamba liye kuluhlu lwe-€26,000–€32,000, ukuba i-EMS ibeka phambili iziganeko ezinexabiso eliphezulu kakhulu.
La ngamanqanaba okusebenza okwenyani, hayi la manani aphezulu okuthengisa. Isiphumo sokwenyani sixhomekeke kwindlela ifektri elayisha ngayo kunye nokuba i-EMS ilungiswe ngokungqongqo kangakanani na.
Into Eyilahlekelwa Yifektri Xa Ukukhetha Ubungakanani Okanye Umthengisi Kungachanekanga
- Umthamo uphela phambi kwefestile ebalulekileyo yokufikelela encotsheni. — Ibhetri iyaphela xa kufika iiyure ezibiza kakhulu okanye incopho yomrhumo. Ifektri isahlawula umrhumo opheleleyo wemfuno kwaye ilahlekelwa yinzuzo yokuthatha umahluko.
- Isilinganiso samandla asinakukwazi ukumelana nokunyuka okukhawulezileyo kwamanqanaba ombane xa kuqaliswa imoto. — Imigca yemveliso idala iincopho ezimfutshane, ezinamandla aphezulu e-kW. Ukuba i-PCS ayikwazi ukuhambisa amandla afunekayo, incopho iyancitshiswa kancinci kuphela kwaye intlawulo yomthamo osetyenzisiweyo ihlala iphezulu.
- Akukho nkxaso yobunjineli emva kokuqaliswa kokusebenza — Xa inkqubo ifuna ukulungiswa kwakhona ngenxa yetarifu entsha okanye isivumelwano somdibanisi, inkampani yorhwebo esele ihlawulwe isoloko ingafumaneki. Ibhetri iyaqhubeka isebenza ngaphantsi komgangatho kwaye inzuzo ebaliweyo ayikhe ifezeke.
Enyanisweni, umahluko phakathi kwenkqubo yomenzi wokuqala exhaswa kakuhle kunye neyunithi ethengisiweyo engaxhaswayo, ngumahluko phakathi kweenani ezingentla kunye nenkqubo esebenza kakubi ngokuthe cwaka iminyaka.
Kutheni uMvelisi Wokuqala ebalulekile kwiziBuyiso ezi
MegSolid iyila kwaye ivelise zombini iikhabhathi. Kwiiprojekthi zeefektri zaseYurophu loo mahluko ubonakala kwiindawo ezine ezithile:
- Iiparamitha ezipapashiweyo ezinokusetyenziswa ngokuthe ngqo kubalo (215.04 kWh, 261.24 kWh, 100 kW, 125 kVA, IP54, ubomi bomjikelo, ukusebenza kakuhle)
- Ulawulo lobushushu olulungiselelwe ukusetyenziswa ngaphandle olugcina inkqubo ingaphakathi kwifestile yayo ebekiweyo kwimozulu yaseYurophu.
- Amandla okusebenza ngokunxuseneyo kwikhabhathi ye-Liquid-Cooled xa iyunithi enye ingasanelanga
- Inkxaso yobunjineli eyaqhubeka ifumaneka emva kofakelo lokulungiswa kwe-EMS notshintsho lwamaxabiso.
Ezinye iinketho: Uluhlu olupheleleyo lweemveliso ze-C&I ze-Solid-State Imvelaphi yenkampani: Malunga neMegSolid
Uluhlu lokujonga lwezigqibo olusetyenziswa ngabaphathi bamandla abanamava kumaziko emveliso
- Fumana irekhodi yokwenene yebango lomthamo lwemizuzu eyi-15 okanye eyi-30 kunye netarif yentlawulo yebango elichanekileyo.
- Chonga iifestile eziphakamileyo ngokuxabiseka kunye nomahluko wamaxabiso onokufunyanwa ngokwenene.
- Lungisa isipaji se-SOC ekufuneka sigcinelwe isiganeko esilandelayo.
- Thelekisa amandla kunye ne-enerji efunekayo phakathi kwe-Outdoor Cabinet eyi-100 kW / 215.04 kWh kunye ne-cabinet eyi-Liquid-Cooled eyi-125 kVA / 261.24 kWh.
- Qinisekisa ukuba inkxaso yobunjineli iza kuba ikhona nasemva kokuqaliswa kokusebenza.
- Kuphela ngoko ke cela ikowuteshini ebandakanya i-EMS control logic.
Ukuvala
I-Peak-valley arbitrage kunye ne-demand response zihlawula kuphela xa ubalo luqala kumandla asetyenziswayo, amandla afunekayo kunye negcini ye-SOC ekufuneka ikhuselwe. I-ESSAs0100B-0215 Outdoor Cabinet kunye ne-261.24 kWh Liquid-Cooled Hybrid Solid-State cabinet zinika amanani akhokelayo afunekayo kuloo mbalelo. Ukukhetha umthamo ongachanekanga, isilinganiso samandla esingachanekanga okanye umthengisi oshiyayo emva kokuhanjiswa kwenza iprojekthi enethemba ibe yimpahla engasebenzi kakuhle iminyaka.
Imibuzo Ebuzwa Rhoqo
Zeziphi iimveliso ezimbini zeMegSolid ezisetyenziselwa ukubalwa kwe-European peak-valley kunye ne-demand-response?
Ikhabhathi yangaphandle i-ESSA0100B-0215 enomlinganiselo we-100 kW / 215.04 kWh kunye nekhabhathi ye-Liquid-Cooled Hybrid Solid-State enomlinganiselo we-125 kVA / 261.24 kWh.
Yeyiphi eyona ndlela yexabiso ethembekileyo kwiiprojekthi ze-BESS kumaziko aseYurophu?
Ukunqamla umphakamo kudla ngokuba yeyona ndlela inenzuzo kakhulu kuba kunciphisa ngqo olona nani luphezulu lwe-kW olumisela intlawulo yomthamo.
Kusele malini yamandla asebenzisekayo kwi-215.04 kWh ye-Outdoor Cabinet emva kokusebenza kakuhle kunye negcini ye-SOC?
Emva kokusebenza kakuhle kunye negcina eliqhelekileyo le-15–20 % SOC, amandla asetyenziswayo ngesiphindaphindo ngamanye amaxesha akwizinga eliphakathi kwe-160–175 kWh.
Yeyiphi uluhlu lwexabiso lonyaka olunokuhanjiswa yi-215.04 kWh Outdoor Cabinet phantsi kwetarifa engumzekelo?
Phantsi kweentlawulo zomrhumo zokufuna ezingaphantsi kwe-€12/kW/ngenyanga kunye nokusasazwa kwe-€0.12/kWh, ixabiso elidibeneyo lokunciphisa umthamo ophezulu kunye ne-arbitrage lidla ngokuba yi-€21,000–€26,000 ngonyaka phambi kwe-O&M.
Yeyiphi uluhlu lwexabiso lonyaka olunokuhanjiswa yikhabhathi ye-261.24 kWh epholisiweyo ngokuyi-liquid phantsi kweemeko ezifanayo?
Ngemva kwesipaji esifanayo, xa kusetyenziswa amandla aphezulu, ixabiso elidibeneyo lokunciphisa ixesha eliphezulu kunye ne-arbitrage lidla ngokufikelela kwi-€26,000–€32,000 ngonyaka xa i-EMS ibeka phambili iziganeko ezinexabiso eliphezulu kakhulu.
Kwenzeka ntoni ukuba amandla ebhetri aphele phambi kwefestile ebalulekileyo yokufikelela encotsheni?
Ifektri isahlawula intlawulo epheleleyo yombane ofunwayo kwaye ilahlekelwa yinzuzo yokuthengisa ngokwahlukeneyo kwiiyure ezinexabiso eliphezulu.
Kutheni isilinganiso samandla sibalulekile ekunciphiseni umthwalo oxhaphakileyo?
Imigca yemveliso idala ukunyuka okufutshane kwamandla aphezulu e-kW. Ukuba i-PCS ayikwazi ukuhambisa amandla afunekayo, incopho iyancitshiswa kancinci kuphela kwaye intlawulo yomthamo osetyenzisiweyo ihlala iphezulu.
Yintoni ingozi yokukhetha inkampani yorhwebo endaweni yomenzi wokuqala?
Xa i-EMS idinga ukulungiswa kwakhona ngenxa yesivumelwano esitsha semali-tariye okanye se-aggregator, inkampani yorhwebo esele ihlawulwe isoloko ingafumaneki, nto leyo eshiya inkqubo isebenza ngaphantsi komgangatho ophezulu iminyaka.
Zeziphi izinga lokhuseleko zombini iikhabhathi ezicetyiswayo?
Zombini i-Outdoor Cabinet kunye ne-Liquid-Cooled Hybrid Solid-State cabinet zinomgangatho we-IP54.
Zingaphi iikhabhathi ze-Liquid-Cooled Hybrid Solid-State ezinokudityaniswa zisebenze ngaxeshanye?
Kuya kutsho kwiiyunithi ezili-10 zekhabhathi ye-261.24 kWh epholisiweyo ngokululwelo ezinokudityaniswa zisebenze ngokunxuseneyo.
Ubomi besayikile elipapashiweyo lwe-ESSA0100B-0215 Outdoor Cabinet bungakanani?
Ubomi obupapashiweyo bemijikelo bubungama-5,000 okanye ngaphezulu kwemijikelo.
Yeyiphi eyona mpumelelo iphezulu yesistim yekhabhathi ye-261.24 kWh epholisiweyo ngokwamanzi?
Eyona nkqubo isebenza kakuhle ipapashiweyo yi-90 %.
Ngowuphi umgangatho ekufuneka kubekwe ngayo ezi ntsinga zixabiso zithathu?
Kuqala ukunciphisa umthamo ophezulu, kulandele i-arbitrage, kulandele impendulo yemfuno. I-arbitrage kunye nempendulo yemfuno zongeza ixabiso kuphela emva kwefestile yomthamo ophezulu obalulekileyo xa isipaji se-SOC kunye nendawo egciniweyo zikhuselwe.
Amaphepha asemthethweni emveliso yee-khabhinethi ezimbini anokufunyanwa phi?
Ikhabhathi yangaphandle: https://www.solidess.com/product/outdoor-cabinet-energy-storage-system/ I-Hybrid Solid-State epholisiweyo ngokwamanzi: https://www.solidess.com/product/megsolid-solid-liquid-energy-storage/
Ifektri yaseYurophu ingacela njani uphononongo lobuchwepheshe lokulinganisa?
Qhagamshelana neqela lobunjineli laseMegSolid ku-https://www.solidess.com/contact-megsolid/ kwaye unikeze irekhodi lokwenene lomthwalo wemizuzu eli-15 okanye engama-30 kunye netarif yentlawulo yomthwalo echanekileyo.
Yeyiphi itekhnoloji engundoqo esetyenziswayo kwikhabhathi epholisiweyo ngamanzi enomthamo we-261.24 kWh?
Ikhabhathi isebenzisa iiseli zeHybrid Solid-State (eziziimixube eziqinileyo) ezineenkqubo zokupholisa ulwelo ezikrelekrele ezigcina umahluko wamaqondo obushushu eeseli ungagqithi kwi-±5 °C.