Khuphela iPDF yezichazi zobuchwepheshe
The MegSolid ESsA0100B-0215 combines 10ekl rated AC power with 215.04kwh of battery storage in an IP54 outdoor cabinet. The system uses intelligent air cooling and supports 40ev, 50/60Hz operation for commercial and industrial energy-storage projects.
The ESSA range covers 30-10okw and 55.296-215.04kth. Select the model from the site load profile, required discharge duration and AC voltage, then confirm usable energy, auxiliary consumption, temperature limits and FAT/SAT acceptance values.

Ipasi-5, i-4

Ukhuselo lwengeno

3,000m

Operating altitude

<75

Noise emission (dB)

I-voltage elinganisiweyo (V)

400

Uluhlu lwe-voltage (iV)

320V-460V

Rated frequency

50/60Hz

Uluhlu lweemvamisa

AC data

Iinkcukacha zobuchwepheshe

AC data

Umzekelo

ESSA0030B-0055 | ESSA0050B-0055 | ESSA0050B-0100 | ESSA0100B-0215

Rated power (kW)

30 | 50 | 50 | 100

Rated current (A)

43 | 72 | 72 | 144

THDi(on-grid)

Ngaphantsi kwe-3%

THDu (off-grid)

≤ 1% linear; ≤ 5% non-linear

Umlinganiselo wamandla

1 (0.8 leading ~ 0.8 laging can be set)

Umthamo woxinzelelo olugqithisileyo

110% Long term

Isiphumo se-AC

3W+N+PE

lsolation trans

100/400 | 200/400 | 200/400 | 270/400

On -grid off-grid switching

Inkxaso

PV data

MPPT operating voltage range (V)

250~850

MPPT full load voltage range (V)

450~850

Max. PV input voltage (V)

1000

Max. PV power (kW)

60/120 | 60/120 | 60/120 | 120/180/240

Buck-boost mode

Inkxaso

Battery data

Cell type

3.2V/120Ah/1C,LFP | 3.2V/120Ah/1C,LFP | 3.2V/280Ah/1C,LFP | 3.2V/280Ah/1C,LFP

Nominal voltage(V)

460.8V,1P144S | 460.8V,1P144S | 358.4V,1P112S | 768V,1P240S

Nominal energy (kWh)

55.296 | 55.296 | 100.352 | 215.04

Working voltage range (V)

403.2~511.2 | 403.2~511.2 | 319.2~397.6 | 672~850

Max. charge and discharge rate

1C@25℃ | 1C@25℃ | 0.5C@25℃ | 0.5C@25℃

Number of Battery Cycles

≥3,800 | ≥3,800 | ≥5,000 | ≥5,000

System data

Dimensions W *D *H (mm)

1,770×1,510×2,270 | 1,770×1,510×2,270 | 1,770×1,510×2,270 | 2,450×1,550×2,400

Net weight (kg)

2,000 | 2,200 | 2,400 | 3,900

Operating temperature (℃)

0 ~ +45

Umswakama oxelanisiweyo

0 ~95%(non-condensing)

Ukubandisa

Ukupholisa umoya okubukrelekrele

fire extinguishing system

Aerosols/NOVEC1230

Ukubonisa

Touch LCD display+cloud platform

Unxibelelwano lwe-EMS

RS485,TCP/IP

Fumana isisombululo sakho seMegSolid sokugcina amandla kwiiyure ezingama-24.

Ngqo kumvelisi weebhetri ze-solid-state. Fumana isiphakamiso se-ESS esenziwe ngokweemfuno zakho, uhlalutyo lwe-ROI, kunye nesindululo senkqubo kwiqela lethu lobunjineli.

Into Oza Kuyifumana

Ityelelwe ehlabathini lonke:

UL, IEC, UN38.3, China Classification Society, GB36276-2023, RoHS

Iimodeli ezishushu:

Izicelo:

Iifektri · Iifama zelanga · Ezemigodi · IiZiqithi · Iziko leDatha