Ii-inverters ze-hybrid ze-three-phase i-MegSolid R30KH3–R50KH3 zibonelela ngemveliso ye-AC elinganisiweyo ye-30 kW, 40 kW kunye ne-50 kW kwiiprojekthi zelanga zorhwebo + zokugcina amandla, amandla okuxhasa kunye ne-microgrid. Ii-R30KH3, R40KH3 kunye ne-R50KH3 zixhasa amandla aphezulu angenayo e-PV angange-45 kW, 60 kW kunye ne-75 kW ngokulandelelanayo, kunye namandla aphezulu okutshaja/okukhupha angange-33 kW, 44 kW kunye ne-55 kW. Le series ixhasa uluhlu lwe-voltage yebhetri oluphakathi kwe-150–800 V kwaye iyahambelana neebhetri ze-MegSolid hybrid solid-state kunye neebhetri eziqhelekileyo ze-lithium-ion. Isebenzisa ujongano lwegridi lwe-380/400 V, 3W+N+PE, inika utshintsho lwebheki olungaphantsi kwe-10-ms, ukhuseleko lwe-IP65, kunye nomlinganiselo wobushushu bokusebenza oqala kwi-35°C engaphantsi ukuya kwi-60°C engaphezulu. Kwiiprojekthi ezifuna iitshaneli ezine ze-MPPT okanye i-output yomthwalo ongabalulekanga ye-100%, khetha imodeli ye-R50KH3.
IP65
Ukhuselo lwengeno
73kg
Ubunzima (kg)
RS485
Meter
HM
APP; touch panel
BMS
RS485,CAN
Iinkonzo zonyango ezingxamisekileyo
RS485
Supported communication interface
Battery data and General data
Iinqobo zethu ezingundoqo
Battery data and General data
Model
R30KH3 | R40KH3 | R50KH3
Max. charging / discharging power (kW)
33kW | 44kW | 55kW
Battery voltage range (V)
150–800V
Max. charging / discharging current(A)
80*2
No. of battery input
2
Battery type
Lithium-ion
Operating altitude (m)
4,000(>2,000 power derating)
Ukubandisa
Forced air cooling
Noise emission (dB)
≤65
Installation
Wall mounted type
DC input data
Max. PV input power (kW)
45kW | 60kW | 75kW
Max. PV voltage (V)
1000
MPPT voltage range (V)
150–850V
Start-up voltage (V)
180
Max. input current per MPPT (A)
40 / 40 / 40 / 40
Max. short-circuit current (A)
60 / 60 / 60 / 60
No. of MPPT trackers
4
No. of PV strings per MPPT
2
Rated input voltage (V)
600
AC output data (on-grid)
Rated AC output active power (kW)
30kW | 40kW | 50kW
Max. AC output apparent power (kVA)
33 | 44 | 55
Rated AC output current (A)
45.6A | 60.8A | 76A
Max. AC output current (A)
50.1A | 66.9A | 83.6A
Max. continuous AC pass-through(grid to load) (A)
200
Rated grid voltage (V)
380 / 400
Power factor
>0.99 (0.8 Leading ~ 0.8 Lagging)
Grid type
3W+N+PE
Rated grid frequency (Hz)
50/60
THDi
<3%
AC output data (off-grid) and General data
Rated output power (kW)
30 | 40 | 50
Max. apparent power (kVA)
33 | 44 | 55
Rated output voltage (V)
380 / 400, 0.85Un-1.1Un
Back-up switch time (ms)
<10ms
Grid type
3W+N+PE
THDu
<2%
Dimensions W*D*H (mm)
530×280×850mm
Operating temperature range (℃)
-35°C–60°C
Inverter topology
Non-isolated
Relative humidity
0~100%