Khuphela iPDF yezichazi zobuchwepheshe

Ii-inverters ze-hybrid ze-three-phase i-MegSolid R30KH3–R50KH3 zibonelela ngemveliso ye-AC elinganisiweyo ye-30 kW, 40 kW kunye ne-50 kW kwiiprojekthi zelanga zorhwebo + zokugcina amandla, amandla okuxhasa kunye ne-microgrid. Ii-R30KH3, R40KH3 kunye ne-R50KH3 zixhasa amandla aphezulu angenayo e-PV angange-45 kW, 60 kW kunye ne-75 kW ngokulandelelanayo, kunye namandla aphezulu okutshaja/okukhupha angange-33 kW, 44 kW kunye ne-55 kW. Le series ixhasa uluhlu lwe-voltage yebhetri oluphakathi kwe-150–800 V kwaye iyahambelana neebhetri ze-MegSolid hybrid solid-state kunye neebhetri eziqhelekileyo ze-lithium-ion. Isebenzisa ujongano lwegridi lwe-380/400 V, 3W+N+PE, inika utshintsho lwebheki olungaphantsi kwe-10-ms, ukhuseleko lwe-IP65, kunye nomlinganiselo wobushushu bokusebenza oqala kwi-35°C engaphantsi ukuya kwi-60°C engaphezulu. Kwiiprojekthi ezifuna iitshaneli ezine ze-MPPT okanye i-output yomthwalo ongabalulekanga ye-100%, khetha imodeli ye-R50KH3.

IP65

Ukhuselo lwengeno

73kg

Ubunzima (kg)

RS485

Meter

HM

APP; touch panel

BMS

RS485,CAN

Iinkonzo zonyango ezingxamisekileyo

RS485

Supported communication interface

Battery data and General data

Iinqobo zethu ezingundoqo

Battery data and General data

Model

R30KH3 | R40KH3 | R50KH3

Max. charging / discharging power (kW)

33kW | 44kW | 55kW

Battery voltage range (V)

150–800V

Max. charging / discharging current(A)

80*2

No. of battery input

2

Battery type

Lithium-ion

Operating altitude (m)

4,000(>2,000 power derating)

Ukubandisa

Forced air cooling

Noise emission (dB)

≤65

Installation

Wall mounted type

DC input data

Max. PV input power (kW)

45kW | 60kW | 75kW

Max. PV voltage (V)

1000

MPPT voltage range (V)

150–850V

Start-up voltage (V)

180

Max. input current per MPPT (A)

40 / 40 / 40 / 40

Max. short-circuit current (A)

60 / 60 / 60 / 60

No. of MPPT trackers

4

No. of PV strings per MPPT

2

Rated input voltage (V)

600

AC output data (on-grid)

Rated AC output active power (kW)

30kW | 40kW | 50kW

Max. AC output apparent power (kVA)

33 | 44 | 55

Rated AC output current (A)

45.6A | 60.8A | 76A

Max. AC output current (A)

50.1A | 66.9A | 83.6A

Max. continuous AC pass-through(grid to load) (A)

200

Rated grid voltage (V)

380 / 400

Power factor

>0.99 (0.8 Leading ~ 0.8 Lagging)

Grid type

3W+N+PE

Rated grid frequency (Hz)

50/60

THDi

<3%

AC output data (off-grid) and General data

Rated output power (kW)

30 | 40 | 50

Max. apparent power (kVA)

33 | 44 | 55

Rated output voltage (V)

380 / 400, 0.85Un-1.1Un

Back-up switch time (ms)

<10ms

Grid type

3W+N+PE

THDu

<2%

Dimensions W*D*H (mm)

530×280×850mm

Operating temperature range (℃)

-35°C–60°C

Inverter topology

Non-isolated

Relative humidity

0~100%

Fumana isisombululo sakho seMegSolid sokugcina amandla kwiiyure ezingama-24.

Ngqo kumvelisi weebhetri ze-solid-state. Fumana isiphakamiso se-ESS esenziwe ngokweemfuno zakho, uhlalutyo lwe-ROI, kunye nesindululo senkqubo kwiqela lethu lobunjineli.

Into Oza Kuyifumana

Ityelelwe ehlabathini lonke:

UL, IEC, UN38.3, China Classification Society, GB36276-2023, RoHS