Laai Tegniese Spesifikasies PDF af

MegSolid MG-ESS-500W-230-resensie: 500W / 1004,8Wh draagbare hibriede vaste-toestandkrag

Die MegSolid MG-ESS-500W-230 is 'n 500W draagbare kragstasie met 'n beoordeelde energie van 1004,8Wh en 'n netto gewig van 10 kg. Hierdie artikel beantwoord drie vrae van kopers direk: watter laste val binne die 500W-limiet, hoe lank die battery hulle kan laat werk, en watter tegniese dokumente en markweergawedetails voor bestelling bevestig moet word.

MegSolid MG-ESS-500W-230 500W 1004,8Wh draagbare hibriede vaste-toestand kragstasie

Begin met die las: Is 500W genoeg?

Die Amptelike MG-ESS-500W-230 produkbladsy Spesifiseer 500 W volbelastingkrag, 230 VAC-uitset en 'n suiwer sinusgolf. Voeg die deurlopende wattage van elke toestel by wat terselfdertyd sal werk. As die totaal bo 500 W is, is hierdie model nie die korrekte keuse nie.

MegSolid MG-ESS-500W load fit and theoretical runtime decision infographic

Teoretiese maksimum uitvoertydperk = 1004,8 Wh ÷ belastingkrag. Dit is nie 'n gelewerde-uitvoer-tydgarantie nie. Inverterverlies, stilstandverbruik, temperatuur, batteryleeftyd en die werklike lasprofiel verminder die werklike bedryfstyd.

Voorbeeld deurlopende lasTeoretiese boonste grensKoperinterpretasie
60WOngeveer 16,7 uurDie werklike bedryfstyd sal na omskakeling en wagtydverliese laer wees.
120WOngeveer 8,4 uurGebruik dit as 'n maksimum, nie as 'n belofte van 8–10 uur nie.
300WOngeveer 3,3 uurBevestig temperatuur, omvormerdoeltreffendheid en reserwevereiste.
Bogenoemde 500WNie van toepassing nieKies 'n model met 'n hoër krag.

Wat die gepubliseerde spesifikasie bevestig

AankooppuntGepubliseerde spesifikasieWat die Koper moet verifieer
Gegradueerde energie1004,8 WhBenodigde reserwe en verwagte bruikbare AC-energie
Wisselstroomuitset500W, 230Vac, suiwer sinusgolfSokkeltipe, frekwensie en bestemmingsmarkweergawe
Netto gewig / afmetings10kg / 276 × 185 × 199mmGewig, bykomstighede en versendingskarton
Soninset10–55 V gelykstroom, 10 A, 300 W maksimumPaneel-VOC, huidige waarde, connector en koue-weer-VOC
UPS-skakeling≤20msOf die gekonnekteerde toestel daardie interval kan deurkom.
LewensiklusTot 8 000 siklusseDOD, temperatuur, C-koers, einde-van-leeftyd-drempel en toetsverslag
WaarborgGepubliseer as 5 jaarStreekvoorwaardes, uitsluitings, eisproses en logistiek

Vir tekeninge, toetsrekords en huidige dokumentweergawes, gebruik die MegSolid tegniese hulpbron-sentrum en versoek die model-spesifieke pakket eerder as om op 'n algemene produkfamilie-verklaring staat te maak.

Hibriede vaste-toestand-veiligheid: Stel die voordeel presies

MegSolid beskryf die eenheid as een wat hibriede vaste-toestandbatterijtegnologie gebruik. Die beoogde voordeel is 'n verminderde vloeibare-elektrolietinhoud en verbeterde termiese stabiliteit in vergelyking met 'n konvensionele vloeibare-elektrolietontwerp. Die Oorsig van hibriede vaste-toestand-veiligheid verduidelik die materiaalvlakmeganisme.

Hierdie voordeel moet nie herskryf word as “nul risiko” of “termiese ontsnapping is onmoontlik” nie. Veilige ontplooiing hang steeds af van die BMS, omhulsel, laaier, bedryfstemperatuur, vervoertoestand en korrekte gebruik. Aankoopbesluite moet gebaseer wees op modelspesifieke veiligheidsverslae en sertifikate.

1004,8 Wh by 10 kg: Draagbaar, maar die bedryfstyd hang steeds af van die las

Die gepubliseerde netto gewig van 10 kg en die afmetings 276 × 185 × 199 mm maak die eenheid geskik vir vervoer deur een persoon. Dit beteken nie dat elke 1 kWh-mededinger swaarder is nie, dus vermy die artikel onondersteunde markwye gewigsbereike en vergelyk die eenheid slegs met die koper se eie hanteringslimiet.

MegSolid publiseer ook 'n MG-ESS-500W prestasietoets oorsig dek soninset, volbelastingbedryf, temperatuurtoetse en bewerings oor sikuslewe. Kopers moet die onderliggende, modelspesifieke toetsdokumente versoek wanneer daardie bewerings 'n tender of verspreidingsooreenkoms beïnvloed.

Sonlaai en UPS-gebruik vereis versoenbaarheidsondersoeke

Koperverifikasielys

MegSolid MG-ESS-500W buyer checklist for output, solar input, UPS, cycles, warranty and documents

Oorsien die wyer MegSolid-energiebergingsprodukportefeulje as die vereiste deurlopende krag bo 500 W is. Vir verskafferagtergrond en vervaardigingsomvang, sien Oor MegSolid.

Wie behoort hierdie model te kies?

Sien MegSolid-toepassingsgevalle for other storage use cases. For a model-specific quotation, plug configuration and document checklist, contact the MegSolid team.

VGV

The published rated energy is 1004.8Wh. Usable AC energy will be lower because of inverter loss, standby consumption, temperature, battery age and reserve settings.

Not automatically. The combined continuous load must stay within 500W, and motor or compressor loads also require a startup-surge check.

Use 1004.8Wh divided by the continuous load in watts as a theoretical upper bound, then reduce the result for conversion loss, standby consumption, temperature, aging and reserve.

The official product page publishes a 10kg net weight and dimensions of 276 × 185 × 199mm. Confirm packed weight and included accessories for shipping.

MegSolid describes the battery as a hybrid solid-state design intended to reduce liquid-electrolyte content and improve thermal stability. It should not be marketed as risk-free.

No. Ask for the DOD, temperature, C-rate, end-of-life capacity threshold and applicable test report because cycle life depends on test and operating conditions.

The published input range is 10–55Vdc, 10A maximum and 300W MPPT maximum. Confirm panel Voc, cold-weather Voc, current and connector compatibility.

No. It is a published switching-time specification. The connected device must be able to ride through that interval, so critical loads require an actual transfer test.

The official page lists two national-standard five-hole AC sockets, three USB ports and 5V/12V DC output. Confirm the exact socket version on the quotation for your destination market.

The product page publishes a five-year warranty. Request the regional warranty document, exclusions, claim process and freight responsibility before ordering.

The product page lists −10°C to 50°C for operation and −15°C to 60°C for storage. Confirm any charging or output derating conditions in the current datasheet.

Do not assume so from the pure-sine-wave or switching-time specification. Medical use requires device-specific approval, risk assessment and applicable certification.

Request the current datasheet, product revision, plug and label version, cycle-test conditions, warranty terms, transport documents, destination-market certificates, packaging data and sample-acceptance plan.

Moenie direkte versoenbaarheid aanvaar nie. Bevestig voor aankoop die uitset spanning, frekwensie, sokkonfigurasie en die presiese Noord-Amerikaanse nakomingsdokumente.

Die gepubliseerde uitset is 230Vac, maar kopers moet steeds die soktype, frekwensie, toestelkrag, opstartstoot en nakoming met die bestemmingsmark bevestig.

Bevestig voor bestelling die AU/NZ-prop- en etiketweergawe, die uitgangsfrekwensie, die vervoerdokumente, die toepaslike elektriese goedkeurings, die waarborgdekking en enige invoerderverpligtinge.

Prodუქtreferensie: Official MegSolid MG-ESS-500W-230 product page, checked 14 August 2026: 1004.8Wh rated energy, 500W pure-sine output, 10kg net weight, 276 × 185 × 199mm dimensions, 10–55Vdc / 300W MPPT solar input, published ≤20ms switching time, up to 8,000 cycles and a published five-year warranty.

Vrywaring: Published specifications are screening inputs, not a project guarantee. Actual runtime and service life depend on load, temperature, charge/discharge conditions, battery age and operating reserve. Always use the latest model-specific datasheet, test records, warranty terms and destination-market requirements for procurement.

MegSolid (Hong Kong) Limited fokus op navorsing en ontwikkeling, ontwerp en verskaffing van hoëpresterende energiestoorstelsels. Met tien jaar se tegniese opbou bied ons pasgemaakte buite-kaste ESS, residensiële omvormers en draagbare kragoplossings vir wêreldwye kliënte.
WhatsApp/Wechat: +852 59811073

Kry jou MegSolid-energiebergingsoplossing binne 24 uur

Direk van 'n Vastestaat-batteryvervaardiger. Ontvang 'n pasgemaakte ESS-voorstel, ROI-ontleding en stelselaanbeveling van ons ingenieurspan.

Wat jy sal ontvang

Wêreldwyd Vertrou

UL, IEC, UN38.3, China Klassifikasiesamesetting, GB36276-2023, RoHS

Hot Modelle:

Toepassings:

Fabrieke · Sonplase · Mynbou · Eilande · Datasentrums

Vertel ons van jou projek — ons ontwerp die stelsel vir jou.