Khuphela iPDF yezichazi zobuchwepheshe

Indlela yokuQinisekisa iBhetri ye-Solid-State: Iimpawu ezi-7 ezilumkisayo zabaThengisi

Battery suppliers use solid-state, semi-solid, quasi-solid and solid-liquid labels for different electrolyte architectures. Before paying a technology premium, ask the supplier to define the electrolyte, disclose any liquid content and connect each performance claim to the exact cell and system model.

Check the stated cycle-life conditions, safety-test results, energy density and complete BESS specification. MegSolid describes its products as I-Hybrid ye-Solid-State, meaning the cells combine solid electrolyte materials with liquid components rather than claiming an all-solid-state design.

7 Checks for Verifying a Solid-State Battery

Isigqubuthelo sokuqinisekisa sebhetri ye-hybrid ye-solid-state iMegSolid esibonisa izikali ezine zemveliso yeMegSolid yeli nqaku.

1. Isilumkiso: Umvelisi Akayichazi Ngokucacileyo Ibhetri

Umbuzo wokuqala kufuneka ube lula:

Yeyintoni kanye kanye le bhetri?

Ukuba umthengisi utshintshatshintsha phakathi kwe "all-solid-state," "semi-solid" kunye ne "hybrid solid-state" ngaphandle kokuchaza isakhiwo, awunakuthelekisa iimveliso ngokulinganayo.

Isemi-solid asikokuba yinyani ngokuzenzekelayo. I-hybrid ayizizo zonke zi-solid. I-cell esenengxube enguketshelo isenokuzisa inzuzo yokwenene.

Okubalulekileyo kukuba umenzi uthi na ukuba yintoni ayithengisayo.

Amaxwebhu kaMegSolid achaza itekhnoloji njenge I-Hybrid ye-Solid-State — i-electrolyte eqinileyo kunye namacandelo angamanzi. Ibhetri yokugcina amandla eyi-51.2 V / 314 Ah, umzekelo, ichongwa njenge I-Hybrid ye-Solid-State ye-LiFePO4.

Loo nto ikunika imveliso ecacileyo, hayi ileyibhile yentengiso etshintshayo.

2. Isilumkiso: Umthengisi uthi "Phantse akukho lwelo" kodwa akabonisi mpimo

Kulapho ukufunwa kweempahla kuba yingxaki khona ukuba awulumkanga.

Akukho nasinye sezixwebhu zobuchwepheshe zeMegSolid LLMS esinika inani. ipesenti ye-electrolyte elulwelo kwiibhetri zeMegSolid. Ngoko ke eli nqaku aliyenzi enye.

Kungalunganga ukubhala:

"IMegSolid iqulathe i-X% electrolyte elulwelo."

ngaphandle kokuba ingxelo esemthethweni yovavanyo lweMegSolid okanye uxwebhu lobuchwepheshe oluhlaziyiweyo ichaza elo nani.

Umthetho ofanayo uyasebenza kwiziphumo zokulahlekelwa kobunzima.

I-T/CSAE 434-2025 yaseTshayina sisalathiso somcimbi kumashishini. Ukuqinisekiswa kwebhetri yokutsala yohlobo oluludaka ngokupheleleyo. Indlela epapashiweyo isebenzisa ukufudumeza nge-vacuum; phantsi kwale ndlela isampuli kufuneka ingabonisi lulwelo olubonakalayo kwaye ireyithi yokulahleka kobunzima ibe ngaphantsi kwe-1% ukuze kufikelelwe kwesi sigqibo.

Loo nani ngu Asiyiyo ipharamitha yemveliso yeMegSolid kwaye akufuneki iboniswe njengento enye. Kananjalo ayisosondelo sokwamkelwa ngokubanzi se-BESS ezimileyo.

Yintoni ekufuneka uyibuzwe

UmbuzoUbungqina obulungileyo
Yintoni isakhiwo se-electrolyte?Isibhengezo sobuchwepheshe
Ingaba ulwelo lukhona?Ingxelo ecacileyo yomenzi
Ingaba kubandakanywa ipesenti?Isiphumo sovavanyo nendlela
Ngaba kuthiwa yi-“all-solid-state”?Ubungqina bokuhlela obusebenzayo

Umthetho: Akukho nani luqinisekisiweyo, akukho nani luqanjweyo.

3. Isilumkiso: Ubomi be-Cycle buncitshiswe ngaphandle kwemodeli echanekileyo.

Kulapho idatha eyodwa yemodeli isigqibezela isingxabano.

MegSolid iyenza hayi Papasha inani elinye lobomi-jikelezo kwimveliso nganye.

MegSolid 51.2V / 314Ah Ibhetri yokugcina amandla eqinileyo

IpharamithaIxabiso eliqinisekisiweyo
ItekhnolojiI-Hybrid ye-Solid-State ye-LiFePO4
Umthamo314 Ah / 16.07 kWh
I-voltage enikwe igama51.2 Volt
Ivayenti yokusebenza43.2–57.6 V
Ubomi beSithuthuthuAmajikelezo angama-8000
Imeko yesithuthuthu ichaziwe80% DoD

MegSolid MB 512314

IpharamithaIxabiso eliqinisekisiweyo
Uhlobo lwebhetriI-LFP eNziwe ngokuDityanisiweyo kwi-Solid-State
Umthamo16,076 Wh / 314 Ah
Ubomi beSithuthuthuIijikelezo ezingama-6000 nangaphezulu
Vavanya iqondo lobushushu25°C
Isiphelo sobomi bemveliso80%
IwarantiIminyaka emihlanu

Loo mahluko yiyo kanye ingongoma:

Ungaze ukope ubomi benkqubo bemveliso enye yeMegSolid kwesinye.

Buza "Yeyiphi imodeli?" phambi kokuba ubuze "Zingaphi iisayikili?"

Uthelekiso lobomi-jikelezo lweMegSolid lwe-MEGA-512314FL1 ne-MEGA-512314 Mobile, kusetyenziswa iimeko zovavanyo ezipapashiweyo ezizodwa kwimodeli nganye.

4. Isilumkiso Esicacileyo: "Okukhuselekileyo" Kuthathwa NjengeNkcazelo Epheleleyo

Ukhuseleko lufuna isidima esifanayo.

Isiseko solwazi seMegSolid sichaza ukhuseleko lwangaphakathi kunye nomngcipheko oncitshisiweyo wokuphuma kweqondo lobushushu njengeenzuzo ezingundoqo zeHybrid Solid-State. Kunjalo. hayi Nika isiphumo esinye esiqhelekileyo esingumanani sokunyuka kobushushu obungenakunqandwa, esibandakanya yonke imveliso.

Ngoko ke, musani ukuqamba imigca efana nale:

"Iibhetri zeMegSolid azinathuba lokuphuma emkhawulweni wobushushu."

okanye

"IMegSolid ikhuseleke ngokuphindwe i-X kune-LFP elulwelo."

La manani akukho kwiifayile.

Sebenzisa iinkcukacha zokhuseleko ezidweliswe ngokwenene kwinkqubo nganye.

Kwabantu abathile 261.24 kWh yeNkqubo yokuGcina uMbane iHybrid yeSolid-State, isiseko solwazi sidwelisa:

Ezo ziinkcukacha ezicacileyo zesistim. Zidlula "ipesenti yokhuseleko" eyinqambi ngalo lonke ixesha.

5. Isilumkiso Esibomvu: Itekhnoloji Yeeseli Isetyenziselwa Ukufihla Idatha Yesixokelelwano Ebuthathaka

Iprojekthi yokugcina ayakhiwa ngolwimi lwentengiso.

Yakhiwe nge:

amandla + ivoltheji + amandla ombane + ukupholisa + ukhuseleko + ulawulo + ukudityaniswa okwenyama.

Kulapho MegSolid inokubonisa ngaphezu kwelebheli yekhemistri.

Inkqubo yayo ye-Hybrid Solid-State C&I ineeparamitha zenqanaba lenkqubo ezibhalwe phantsi:

IpharamithaMegSolid 261.24kWh C&I ESS
Amandla Alinganisiweyo261.24 kWh
IseliI-Hybrid Solid-State LFP-314Ah
Uqwalaselo1P260S
Uluhlu lweVoltage ye-DC676–936 Vdc
Ivoltheji ye-DC enikwe igama832 Vdc
Amandla ombane we-AC amiselweyo125 kVA
Ukusebenza kakuhle okuphezulu kweNkqubo90%
UkubandisaUkupholisa okubukrelekrele okwamanzi
UkhuseloIpasi-5, i-4

Oko kusisiseko esomeleleyo sokugweba ngemveliso yokugcina yorhwebo kunomgca:

"Iseli yethu ikwimeko eqinileyo."

6. Isilumkiso Esicacileyo: Imveliso eyi-5 MWh ithelekiswa nebhetri encinci kusetyenziswa iparamitha enye eqhelekileyo

Isikali sibaluleke njengokwakheka.

MegSolid documents the 5000INTL separately from its smaller battery and C&I energy-storage systems.


IpharamithaI-5000 yangaphakathi
Amandla Alinganisiweyo5015.9 kWh
Uhlobo lwebhetriSHS180-314
Uhlobo lwebhetriSHS180-314
I-volteji elinganisiweyo1331.2 Volt zedijithali
Amandla ombane we-AC amiselweyo450 × 6 kW
I-voltage ye-AC690 Volt eziguquguqukayo
Ukusebenza ngokugqibeleleyo87.5%
UkhuseloIpasi-5, i-5
Ukuphakama okuphezulu≤4000 m
Uqwalaselo12P416S

Ukwethenjwa kuxhomekeke Uchannelo lwe-model-to-parameter.

Musa ukuthatha:

kwaye uziqhube njengeenani zeMegSolid ezipheleleyo.

Oko kudala idatha engeyonyani, nokuba onke amanani nganye akhona ndaweni ithile kwisiseko solwazi.

Uthelekiso lwenkqubo olupheleleyo phakathi kwe-261.24 kWh Energon C&I ESS kunye ne-5000INTL 5015.9 kWh BESS.

7. Red Flag: Chemistry and Electrolyte Type Are Treated as the Same Thing

La mazwi adinga unonophelo.

Isiseko solwazi sikaMegSolid sichonga iimveliso ezininzi njenge I-LFP eNziwe ngokuDityanisiweyo kwi-Solid-State.

Ngoko ke ibinzana:

"Isimo esiqinileyo vs LFP"

Ingaba yimpazamo ngokobuchwepheshe.

I-LFP yikhemistri yekathodi. I-hybrid solid-state yisakhiwo se-electrolyte.

Ibhetri ingaba zombini:

LFP + I-Hybrid ye-Solid-State.

Uthelekiso olucocekileyo ludla ngokuba:

I-Hybrid Solid-State LFP xa ithelekiswa ne-LFP yesiqhelo ene-electrolyte elulwelo

Oko kuyangqinelana nendlela idatha yemveliso yeMegSolid ebhalwe ngayo.

Itheyibhile yamagama angundoqo ekhawulezayo

IsigamaIbalasele Kakhulu Kwi
LFPIkhemistri yekathodi
I-Hybrid ye-Solid-StateIsakhiwo se-electrolyte / iseli
Okuphakathi kokuba lulwelo nobutyoboUlwakhiwo lwe-electrolyte oluxubekileyo
I-LFP elulweloI-LFP enesakhiwo se-electrolyte elulwelo esiqhelekileyo
I-LFP eNziwe ngokuDityanisiweyo kwi-Solid-StateIkhemistri ye-LFP enesakhiwo se-electrolyte esidityanisiweyo esiqinileyo neselulwelo

Yintoni eyenza iMegSolid ifanele ukuqwalaselwa?

Eyona ngqondo yomeleleyo yeMegSolid kukuba ingayibaxisi ikhemistri.

Kukubonisa ukuba iimveliso zeHybrid Solid-State sele zibhalwe phantsi kumaxabiso ahlukeneyo eenkqubo.

Isiseko solwazi lobuchwepheshe siquka:

Oko kunika abathengi into ephathekayo abanokuyijonga:

imveliso → imodeli → ipharamitha → isicelo

Endaweni ka:

Intetho edumileyo → ibango elingenaxhaso.

KwaMegSolid, yiyo loo ntshayelelo inamandla ngakumbi.

China’s Solid-State Battery Standards: Current Status

China published GB/T 48093.1-2026, Electric Vehicle Solid-State Batteries—Part 1: Terms and Classification, on August 28, 2026. The standard takes effect on January 1, 2028. Its scope covers solid-state batteries used in electric-vehicle research, development and testing.

The China Society of Automotive Engineers has also published T/CSAE 434-2025, Determination Methods for All-Solid-State Batteries. This group standard defines an all-solid-state battery and provides a method for testing liquid content.

These documents address vehicle batteries and all-solid-state classification. Stationary energy-storage projects must still apply the standards and acceptance requirements relevant to electrical energy storage. GB/T 36276-2023 remains the current Chinese national standard for lithium-ion batteries used in electrical energy storage.

UxwebhuCurrent statusUmda
T/CSAE 434-2025Published group standardAll-solid-state battery determination and liquid-content testing
GB/T 48093.1-2026Published; effective January 1, 2028EV solid-state battery terms and classification
GB/T 36276-2023Current; effective July 1, 2024Lithium-ion batteries for electrical energy storage

 

Ukuqinisekisa kwemizuzwana engama-60

Ukuba uMthengisi uthi…Buza…
“Isimo esiqinileyo”Ingaba yihibridi, isiqingatha-sibambeneyo okanye yinto eqinileyo ngokupheleleyo?
“Phantse akukho lulwelo”Yeyiphi ixabiso elilinganisiweyo elingqina oko?
“Ubomi obude bomjikelo”Yeyiphi imodeli neemeko zovavanyo?
“Ikhuselekile kakhulu”Yeyiphi ingxelo yokhuseleko eyixhasayo?
“Ukusebenza okuphezulu”Yeyiphi inkqubo/imodeli?
“Ngcono kune-LFP”I-Hybrid LFP okanye i-LFP elulwelo eqhelekileyo?
“Iwaranti ende”Yeyiphi kanye imveliso neemeko zokusebenza?

Require Model-Specific Evidence Before Paying More

Umthetho olawulayo ulula:

Ukuba ifayile yemveliso ayiniki inombolo, ungayipapashi inombolo.

Ngokwe MegSolid, sele kukho idatha yobuchwepheshe eyaneleyo eqinisekisiweyo yokwenza ingxoxo enamandla ngaphandle kokuyila iinkcukacha ezichaziweyo.

Sebenzisa imodeli yokwenene.
Sebenzisa umthamo wokwenene.
Sebenzisa imeko yokwenene yomjikelo xa kucacisiwe.
Sebenzisa ivoltheji yokwenene.
Sebenzisa isakhiwo senkqubo sangempela.

Xa ipesenti ye-electrolyte, ixabiso lokulahleka kobunzima, isiphumo sokuthelekisa sokuphuma kobushushu okanye enye iparamitha Ayinikezelwanga, musani ukuthetha nantoni na enamanani de kubekho umthombo oqinisekisiweyo.

Oku kugcina umxholo uthembekile kubathengi kwaye ukhuseleke ngakumbi xa kuqhutywa uphicotho lobuchwepheshe kamva.

Imibuzo Ebuzwa Rhoqo

Ibhetri ye-solid-state edityanisiweyo idibanisa Izinto ze-electrolyte eziqinileyo ezinamacandelo alulwelo. Ayisusi ulwelo ngokupheleleyo.

Kwisizinda solwazi seMegSolid, I-Hybrid ye-Solid-State, i-Semi-Solid kunye ne-Solid-Liquid Zibhekisele kumgca ofanayo weemveliso ezixutyiweyo.

Amagama angundoqo: Ibhetri eNgqindilili eNxubekileyo, Ibhetri eSiqingatha-Ngqindilili, Ibhetri eNgqindilili neLikweli

Hayi.

Ibhetri ye-hybrid ye-solid-state isenamazinga alulwelo. Uyilo lwe-all-solid-state lujolise ekuthembeleni kwi-electrolyte eqinileyo ukuhambisa ii-ayoni.

Jonga i Ulwakhiwo lokwenene lwe-electrolyte. Musa ukucinga ukuba yonke imveliso ethengiswa negama elithi "solid-state" yenziwe ngobutyobo kuphela.

Amagama angundoqo: Ibhetri eyi-All-Solid-State, Ibhetri eyi-Hybrid Solid-State, Uyilo lwe-Electrolyte

Qala ngemibuzo emine:

• Kusetyenziswa yeyiphi kanye indlela yokwakha?
• Ingaba umenzi uchaza itekhnoloji ngokucacileyo?
• Ingaba amabango obomi-bhayisikile adityaniswe nemodeli ethile kunye neemeko zovavanyo?
• Ingaba iiparamitha zokhuseleko nezesistim zixhaswe ngamaxwebhu obuchwepheshe?

Igama letekhnoloji asibobungqina.

MegSolid ichaza itekhnoloji yayo ehybrid njengee-electrolytes eziqinileyo kunye namacandelo angamanzi — hayi njenge-all-solid-state ngokungagqibekanga.

Iifayile ezimbini zobuchwepheshe zeMegSolid LLMS eziphononongwe kweli nqaku Musa ukunika ipesenti ye-liquid-electrolyte ngenani..

Eli nqaku alibeki kwaye alilinganisi.

Ukuba iprojekthi idinga inani lomxholo wolwelo, lithathe kwingxelo yobuchwepheshe eqinisekisiweyo yeMegSolid okanye kuxwebhu lovavanyo — hayi ekucingeleni.

Amagama angundoqo: Umxholo we-Electrolyte Elulwelo, Ukuqinisekiswa kweBhetri, Ibhetri Ezingileyo

Kukho Akukho nani libodwa lobomi-jikelezo kwimveliso nganye yeMegSolid..

I- 51.2V / 314Ah ibhetri ye-Hybrid Solid-State ye-LiFePO4 ichazwe kwi Iisayikili eziyi-8000 ku-80% DoD.

I- MB 512314 ipakethe ye-LFP eyi-hybrid ye-solid-state ichazwe ngokwahlukileyo ku Iijikelezo ezingama-6000 nangaphezulu kwi-25°C kunye ne-EOL ye-80%, newaranti yeminyaka emi-5.

Ngenisa umfanekiso wesithuthuthu kwimodeli echanekileyo.

Kuba ubomi besayikili sisiphumo sovavanyo, hayi isiqubulo esingenantsingiselo.

Kuxhomekeke:

Ubunzulu bokukhupha (DoD)
• iqondo lobushushu
• Ireyithi ye-C
• Uluhlu lwe-SOC
• umda wokuphela kobomi
• iindlela zokugcina umthamo

Isiphumo se-8000-cycle asinakuthelekiswa nesiphumo se-6000-cycle ukuba iimeko zovavanyo ziyahluka.

Amagama angundoqo: Ubomi beSijikelo seBhetri, i-DoD, i-EOL, ukugcinwa komthamo

Ewe — kodwa la magama achaza iingqwabaza ezahlukeneyo zeseli.

LFP Ikakhulu yikhemistri yekathodi.

I-Hybrid ye-Solid-State yisakhiwo se-electrolyte / iseli.

Ibhetri ingaba zombini. LFP kunye ne-Hybrid Solid-State.

Idathabheyisi kaMegSolid idwelisa iimveliso ezininzi njenge I-LFP eNziwe ngokuDityanisiweyo kwi-Solid-State.

Uthelekiso oluchanekileyo ludla ngokuba:

I-Hybrid Solid-State LFP xa ithelekiswa ne-LFP yesiqhelo ene-electrolyte elulwelo.

IMegSolid (Hong Kong) Limited igxile kuphando nophuhliso, uyilo kunye nokubonelela ngeenkqubo zokugcina amandla ezikumgangatho ophezulu. Ngalo mava obuchwepheshe esinawo emva kweminyaka elishumi, sinikezela nge-ESS yekhabhathi yangaphandle eyenziwe ngokweemfuno zomthengi, ii-inverters zasekhaya kunye nezisombululo zamandla eziphathwayo kubathengi behlabathi jikelele.
WhatsApp/Wechat: +852 59811073

Fumana isisombululo sakho seMegSolid sokugcina amandla kwiiyure ezingama-24.

Ngqo kumvelisi weebhetri ze-solid-state. Fumana isiphakamiso se-ESS esenziwe ngokweemfuno zakho, uhlalutyo lwe-ROI, kunye nesindululo senkqubo kwiqela lethu lobunjineli.

Into Oza Kuyifumana

Ityelelwe ehlabathini lonke:

UL, IEC, UN38.3, China Classification Society, GB36276-2023, RoHS

Iimodeli ezishushu:

Izicelo:

Iifektri · Iifama zelanga · Ezemigodi · IiZiqithi · Iziko leDatha

Sixelele ngeprojekthi yakho — siza kukuyilela inkqubo.