Khuphela iPDF yezichazi zobuchwepheshe

Indlela yokulinganisa i-Solar + BESS kwizibhedlele zaseMzantsi Afrika: Umzekelo wemithwalo ebalulekileyo ye-170kW

Isibhedlele sasePhondo saseMafikeng eMzantsi Afrika sinika umzekelo oluncedo woluntu wokuyilwa kwe-microgrid yezempilo.

Le projekthi idibanisa inkqubo yelanga ye-AC PV eyi-200kW, isitoreji sebhetri esiyi-400kWh kunye nomthwalo obalulekileyo oxhaswa yi-170kW eqikelelweyo kwiindawo ezibandakanya i-ICU, amagumbi ototyo kunye neSebe leZigulana eziNgxamisekileyo. La ngamanani eprojekthi abhengezwe esidlangalaleni, hayi iinkcukacha zemveliso yeMegSolid.

Nangona kunjalo, la manani mathathu akamiseli ixesha eliqinisekisiweyo lokusebenza kwebhetri yesipili, umgangatho we-PCS, amandla asebenzisekayo ebhetri okanye ixesha lokutshajwa ngelanga.

NjengoMlawuli wezoMveliso noThungelwano loNikezelo kwaMegSolid, ndine-15 leminyaka yamava ekwenzeni iibhetri nasekunikezeleni i-ESS, ndicebisa ukuba ubungakanani benkqubo yesibhedlele bumiselwe ngolu landelelwano:

Ukwahlulwa komthwalo wezonyango → Amandla e-AC asebenzayo ngaxeshanye → Amandla e-AC aqinisekisiweyo nasebenzisekayo → Ixesha lokugcina i-bheki → Ukutshajwa ngelanga → Ulungelelwaniso lwejenereyitha

I- Ipotifoliyo yeMegSolid yokugcina amandla kwe-hybrid solid-state inokuxhasa ubunjineli obukhethekileyo beprojekthi yebhetri, i-PCS kunye nemicrogrid emva kokuba ezi mfuno zokusebenza zichazwe.

Qala ngoDidi lweMithwalo yezoNyango

Inani elibonisiweyo le-170kW kufuneka lithathwe njengomda oqikelelweyo womthwalo obalulekileyo—kungekhona njengobungqina bokuba yonke isekethe edityanisiweyo ifuna umbane ongenazihibe ixesha elifanayo.

Ii-EPC zezibhedlele kufuneka zahlule ishedyuli yemithwalo ebalulekileyo ngokweziphumo zeklinikhi kunye nokunyamezela ukuphazanyiswa.

Udidi lomthwalo wezonyangoIisekethe eziqhelekileyoIsigqibo soyilo esifunekayo
Imithwalo yezifundo zonyango engenaphawoIzixhobo ezikhethiweyo ze-ICU, iisekethi zethiyetha, izilawuli zonyango, izibane zikaxakeka kunye ne-IT yezonyangoIngaba nakuphi na ukuphazamiseka kothutho kuyamkeleka?
Imithwalo yenkxaso ebalulekileyoUkukhethwa kwezinto ezifana nokungeniswa komoya, iilabhoratri, izikhenkcisi zamachiza, amanzi nonxibelelwanoUmjikelo kufuneka uchache ngokukhawuleza kangakanani?
Imithwalo elawulwayo enokulahliwaIindlela zokuxhasa ezingakhawuleziyo ezivunyiweyo sisibhedleleKweyiphi i-SOC apho i-EMS inokuthi ibaqhawule?

Ukwahlulwa okuchanekileyo kufuneka kuvunywe ziqela zesibhedlele zezonyango, zombane, kunye neezibonelelo.

Akufunekanga kunikwe klasi nganye ipesenti efanayo ngaphandle kolinganiso olusetyenziselwayo.

Imigaqo-nkqubo yezikhungo zempilo zaseMzantsi Afrika kunye nesikhokelo seziseko zophuhliso zibeka phantsi ukubaluleka kweenkonzo zobunjineli ezithembekileyo kunye nokubonelelwa ngombane okungapheliyo kwizibonelelo zempilo.

Ibhanela yesikhokelo sokulinganisa i-BESS sokujikelezisa umbane saseMegSolid South Africa, echaza indlela yokulinganisa enamanqanaba ama-4, iifomula zokubalwa kwesikhewu sombane, kunye noluhlu lokujonga lwe-RFQ yobunjineli lwabathengi bezorhwebo.

Ubungakanani PCS Amandla Phambi Kobungakanani bebhetri

Ibhetri ye-400kWh ayinakuxhasa isibhedlele ukuba i-PCS ayikwazi ukuthwala umthwalo obalulekileyo ngexesha elinye.

Kumthwalo owaziwayo we-170kW, i-PCS elinganiselwe ngaphantsi kwe-170kW ayinakukwazi ukunika umthwalo opheleleyo noqhubekayo yodwa.

I-EPC kufuneka ke yongeze iitsheki ezikhethekileyo zeprojekthi ze:

Uluhlu lweenkcukacha zemveliso ezilawulwayo zeMegSolid lubandakanya iimodeli zeMEGA PCS ezinamandla aveliswayo avavanyelweyo angama-150kW, 250kW kunye nama-500kW.

I-MEGA0250TS ibonelela:

IpharamithaIxabiso elikuluhlu lwe-LLMS
Amandla omveliso alinganisiweyo250kW
Amandla aphezulu emveliso275kVA
Uluhlu lwe-voltage ye-DC420–850V
Ukusebenza kakuhle okugqithisileyo97.3%
Ulungiselelo lwe-AC3W+N+PE
Iindlela zokusebenzaOkuxhumekileyo nokuzimeleyo
UkutshintshaUkutshintshela ngokuzenzekelayo phakathi kwegridi nangaphandle kwayo
UkubandisaUmoya oqhutywayo

Olu luhlu lweemveliso lukwaquka itransformer yokwahlula eyakhelweyo kwaye luxhasa ukusebenza ngokunxuseneyo kweeyunithi ezine.

Kumthwalo wesibhedlele we-170kW, i-250kW PCS sisikhokelo sokuhlola sokuqala, hayi imvume yokugqibela yoyilo.

I-EPC kufuneka iqinisekise imfuneko yokwenene ye-kVA, umgca wokugqithisa umthwalo, indlela yokuziphatha kwe-short-circuit, ulungelelwaniso lokhuseleko kunye nefilosofi yokuphindaphinda.

Phonononga Uluhlu lwePCS zokugcina amandla zeMegSolid phambi kokulungisa umzobo wesibhedlele womgca omnye.

Musa Ukuthembisa Iiyure ezi-2.35 ukusuka kwi-400kWh

Olona balo lweplanga yegama lulula lolu:

400kWh / 170kW = iiyure ezi-2.35

Lo ngumlinganiselo nje nje wamandla nomthwalo.

Akubonisi ukuba isibhedlele siza kufumana i-170kW kangangeeyure ezi-2.35 kwibhodi yokutshintsha yomthwalo obalulekileyo.

Ixesha lokwenene lokusebenza kufuneka balwe ngolu hlobo:

Ixesha lokusebenza kwesipele = Amandla e-AC aqinisekisiweyo nasebenzisekayo kwindawo yokuhanjelwa ekuvunyelwene ngayo / Umthwalo oxhaswayo

Ukuze kumiselwe amandla e-AC aqinisekisiweyo nasebenzisekayo, isicatshulwa kufuneka sichaze:

Akukho kwaziso yesibhedlele sikarhulumente okanye kwiifayile zeMegSolid LLMS ezinika la maxabiso achaphazele le projekthi ye-Mafikeng.

Ngenxa yoko, inqaku akufuneki lipapashe ixesha elichanekileyo elinokusetyenziswa ngaphaya komlinganiselo wokubukelwa we-2.35-hour.

I- Isikhokelo sobunjineli sokugcinwa kwamandla se-C&I Icacisa isizathu sokuba umthamo we-DC oqikelelweyo kunye namandla e-AC ahanjisiweyo kufuneka zichazwe ngokwahlukeneyo.

Sebenzisa i-Load Shedding ukulondoloza ixesha lokusebenza lekliniki.

Ukwahlulwa komthwalo wezonyango kuvumela i-EMS ukuba itshintshe umthwalo oxhaswayo njengoko ukuphazamiseka kuqhubeka.

Ulandelelwano olusebenzisekayo lunokuba:

Ukuphucuka kwexesha lokusebenza akunakubalwa de isibhedlele sinikeze i-kW elinganisiweyo yodidi ngalunye lomthwalo.

Umzekelo, ukunciphisa umthwalo oxhaswayo ukusuka kwi-170kW ukuya kwixabiso eliphantsi elilinganisiweyo le-Tier 1 kuya kwandisa ixesha lokusebenza, kodwa inqaku akufuneki liyile elo xabiso liphantsi.

I-EPC yesibhedlele kufuneka ifune ukuba inkcazelo yomsebenzi we-EMS ichaze:

I- Isikhokelo sesakhiwo sonxibelelwano se-BMS ne-EMS Inika isakhelo solawulo se-SOC, ubushushu, ii-alam kunye nemiyalelo yamandla.

Bala ukuvuselelwa kwamandla elanga okuvela kwimveliso egqithisileyo ye-PV.

Iprojekthi yoluntu idibanisa i-200kW AC yamandla elanga (PV) kunye nomthwalo obalulekileyo oqikelelwa kwi-170kW.

Ngethuba elinye elifanelekileyo, xa inkqubo ye-PV ivelisa i-200kW yayo epheleleyo kwaye umthwalo obalulekileyo wesibhedlele uhlala kwi-170kW, intsalela ngokwethiyori yile:

200kW − 170kW = 30kW

Oku akuthethi ukuba ibhetri iyaqhubeka isityala nge-30kW.

Imveliso ye-PV iyatshintsha imini yonke, kwaye umthwalo wesibhedlele usenokwahluka.

Ubalo oluchanekileyo lolu:

Amandla afumanekayo okutshaja ibhetri = Isixa-sixa sombane oveliswe yi-PV ngaphezulu komthwalo wesibhedlele ovela ngaxeshanye ngexesha lokutshajwa kwakhona

Imodeli yelanga yesibhedlele kufuneka ibandakanye:

I-array ye-200kW isenokuxhasa ikakhulu imithwalo yezibhedlele ngexesha lokunqamka kombane, ngaloo ndlela icothise ukuphela kwebhetri endaweni yokuyitshaja ngokukhawuleza.

I- Isikhokelo soyilo lwezakhiwo ezixubeneyo zokugcina amandla elanga Ichaza indlela amandla e-PV, ebhetri, omnatha kunye nejeneretha afanele ukulungelelaniswa ngayo.

Into eBuyiswa yiMegSolid emva koHlolo lokuQala

Emva kokufumana idatha yomthwalo neyombane, iMegSolid ingalungiselela:

Ulungelelaniso lwee-UPS, ii-BESS kunye neeJenereyitha zeDizili

I-BESS yesibhedlele akufuneki itshintshe ngokuzenzekelayo i-UPS ekhoyo okanye ijeneretha yedizili.

Inkqubo nganye inoxanduva olwahlukileyo.

Indlela yombane engaphazamisekiyo

I-UPS ikhusela izixhobo ezingenakunyamezela utshintsho lweemvulophu phakathi kwegridi, i-BESS kunye nejeneretha.

Ixesha elifunekayo lokusebenza kunye nokusebenza kokudlulisela kufuneka zivele kwizixhobo zonyango ezidityanisiweyo nakwimfuneko yombane yesibhedlele.

Inkqubo yokugcina amandla ebhetri

I-BESS ibonelela ngenkxaso yamandla kwangoko, amandla umzuzu ukuya kwiyure, utshintsho lwamandla elanga kunye nozinzo lwe-microgrid.

Ikwazi nokudibanisa ulandelelwano lokuqalisa ijeneretha kwaye inciphise ukuqaliswa okungeyomfuneko ngexesha lokuphazamiseka okufutshane.

Ijenereyitha yedizili

Ijenereyitha ibonelela ngamandla ixesha elide xa ukuvaleka kombane kudlula amandla agciniweyo ebhetri okanye imveliso yelanga inganelanga.

Uyilo kufuneka luchaze:

Ukuthenga i-UPS, i-BESS kunye nejeneretha njengeenkqubo ezingahambelaniyo kudlulisa umngcipheko wolungelelwaniso kumsebenzisi wesibhedlele.

Yeyiphi ubungqina bebetri ekufuneka ifunwe yi-EPC yesibhedlele?

Ukukhetha ibhetri yesibhedlele akufanelanga kuxhomekeke kwileyibhile yekhemistri yodwa.

I-EPC kufuneka icele ubungqina bemodeli kanye ecetywayo kunye nemida yenkqubo.

Ubungqina obufunekayo buquka:

IMegSolid iphuhlisa iibhetri ze-hybrid ze-solid-state kunye nezisombululo ze-ESS ezenziwe ngokukodwa, kodwa ayinguye yonke imveliso yeMegSolid esebenzisa ikhemistri ye-hybrid ye-solid-state. I-database yobuchwepheshe yangoku ifuna ukuba yonke inkcazelo yekhemistri ihlale ijonge kwimodeli ethile.

Iifayile ze-LLMS eziphononongiweyo azidwelisi imveliso yesibhedlele esiqhelekileyo se-hybrid solid-state esiyi-400kWh.

Ngoko ke, imfuno ye-400kWh kufuneka iphathwe njengoyilo olulungiselelweyo de i-MegSolid ikhuphe uqwalaselo lwebhetri olukhethekileyo lweprojekthi kunye nedatasheet elawulwayo.

I- Iprofayile yokuvelisa ye-hybrid ye-solid-state yeMegSolid inikezela ngeteknoloji kunye nemvelaphi yefektri yolo vavanyo.

Uqwalaselo Lwokuqala LweProjekthi YeMegSolid

MegSolid South Africa BESS pre-procurement approval document checklist and single-line diagram, detailing NERSA licensing, Eskom grid boundary, and FAT SAT readiness.

Ngokusekelwe kuphela kumanani eprojekthi abhengeziweyo angama-170kW nama-400kWh, indlela yokuqala yeMegSolid yile:

ImfunekoUkhokelo lwangaphambili
Umthwalo ophezulu obalulekileyo ochazweyoVavanya i-PCS yodidi lwe-250kW
Imfuneko yamandla abonakalayoQinisekisa ngokusekelwe kwi-kVA elinganisiweyo kunye ne-power factor.
Iphleyiti yegama lebhetri ekujoliswe kuyoImfuno yeprojekthi malunga ne-400kWh
Isakhiwo sebhetriKufuneka isiphakamiso esenziwe ngokukodwa ngokwemodeli.
Ingeniso yelangaImodeli evela kwigrafu yokuveliswa kwe-AC PV ye-200kW
Iisekethe ezingaphazamisekiyoLungelelanisa ne-UPS esele ikhona okanye ecetywayo.
Ukuphazamiseka okwandisiweyoDibanisa ijeneretha yedizili
UlawuloI-EMS yomthwalo-ngokwezigaba yesibhedlele kunye nomlawuli wemikrogrid

I-MEGA0250TS idweliswe njenge-250kW yomthamo wokuphuma oqhelekileyo kunye ne-275kVA yomthamo wokuphuma ophezulu, kodwa ulwakhiwo lwebhetri, ukulungelelaniswa kwevoltheji ye-DC kunye neqinisekiso elipheleleyo lesixokelelwano zifuna ubunjineli beprojekthi.

yeMegSolid Inkonzo ye-BESS ye-OEM ne-ODM Yeyona ndlela ifanelekileyo xa iprojekthi ifuna umthamo webhetri ongengowesiqhelo, isingxobo esenziwe ngokukodwa, i-EMS logic eyenzelwe yona, okanye uvavanyo lwafektri olwenziwe ngokukodwa kwisibhedlele.

Into Ekufuneka i-EPC Yesibhedlele Iyingenise

Uphando lokuqala kufuneka lubandakanye:

Without these inputs, a supplier can quote 400kWh of equipment but cannot establish a measurable hospital-runtime obligation.

Define Hospital FAT and SAT Scenarios

The hospital should approve the operating scenarios before equipment production.

How to choose a South African energy storage company by residential, C&I, mining, utility or OEM project type

The FAT and SAT programme should include:

A simple battery charge-and-discharge test does not prove hospital resilience.

Sebenzisa i MegSolid BESS Factory Acceptance Test guide to translate the hospital operating sequence into measurable acceptance criteria.

Final Sizing Decision

The South African reference demonstrates that a 200kW AC solar array and 400kWh BESS can be combined to support an estimated 170kW hospital critical load.

It does not prove a universal 2.35-hour hospital backup guarantee.

2026 top 10 residential energy storage brands comparison South Africa including Tesla, BYD, and MegSolid

The EPC must still establish:

The correct procurement output is not simply “one 400kWh battery.”

It is a coordinated hospital microgrid specification covering the battery, PCS, UPS, solar system, generator, EMS, switchgear and acceptance tests.

Imibuzo Ebuzwa Rhoqo

Umlinganiselo oqhelekileyo umalunga neeyure ezi-2.35. Ixesha lokwenyani eliqinisekisiweyo lokusebenza lidinga amandla e-AC asebenzisekayo kwindawo yokuhanjiswa ekuvunyelwene ngayo.

Kuxhomekeke kwi-SOC eqikelelweyo, ukusebenza kakuhle kunye neempawu zokuphelelwa kobomi ezingazange zinikezelwe kwiifayile zeMegSolid LLMS okanye kwidatha yeprojekthi kawonke-wonke.

Hayi, akunjalo xa yonke i-170kW kufuneka ibonelelwe ngaxeshanye yile PCS. Kufuneka uyilo olunamandla aphezulu.

Hayi. Lo ngumyalelo wokuhlolwa kwangaphambili. Ukuvunywa kokugqibela kufuna isiqinisekiso se-kVA, umthwalo ogqithisileyo, ivoltheji, ukhuseleko, i-harmonic kunye nokuphindaphindwa.

Kholisa ukuba njalo. I-UPS ikhusela izixhobo zonyango ezingapheliyo, ngelixa i-BESS ibonelela ngamandla ahlala ixesha elide kwaye ilungelelanisa ukusebenza kwelanga nejeneretha.

Hayi. Ixabiso le-30kW lenzeka kuphela xa umphumo we-PV uyi-200kW kwaye umthwalo obalulekileyo ngexesha elinye kanye iyi-170kW.

Imodeli esemgangathweni ye-400kWh ayichazwanga kwi-data ye-LLMS ephononongiweyo. Le projekthi ifuna isiphakamiso esenziwe ngokukodwa semodeli.

Ukwahlulwa komthwalo kugcina amandla agciniweyo kwiisekethe ezinokuphumo olukhulu kwezonyango ngexesha lokunqamka kombane okude.

  • Guaranteed usable AC energy
  • Supported load
  • Reserve SOC
  • Ukusetyenziswa okongezelelweyo
  • Temperature conditions
  • Amandla okuphela kobomi
  • Measurement boundary

Ukulahleka kwegridi yovavanyo, ukusilela kwejenereta, ukucinywa kombane, ukhuselo lwe-SOC ephantsi, ukusilela konxibelelwano, ukuqalisa ngaphandle kombane, ukubuyiselwa kunye namandla e-AC asetyenzisiweyo alinganisiweyo.

Yahlula imithwalo yonyango, linganisa amandla ePCS esuka kwisiganeko esiphezulu esenzeka ngaxeshanye, chaza amandla e-AC aqinisekisiweyo anokusetyenziswa kwaye uzenzele umzekelo wokutshajwa kwe-PV usebenzisa idatha yoluhlu lwexesha.

Iyakwazi ukuxhasa umthwalo ixesha elilinganiselweyo. Umlinganiselo oqhelekileyo ziiyure ezi-2.35, kodwa ixesha lokusebenza eliqinisekisiweyo lixhomekeke kumandla e-AC asetyenziswayo kunye nemida yokusebenza yeprojekthi.

Thumela idatha yemithwalo yexesha eliphakathi, iindidi zemithwalo yezonyango, umzobo womgca omnye, iinkcukacha ze-UPS negenerator, isilinganiso se-PV, idatha ye-transformer kunye nexesha elifunekayo lokuxhasa.

IMegSolid (Hong Kong) Limited igxile kuphando nophuhliso, uyilo kunye nokubonelela ngeenkqubo zokugcina amandla ezikumgangatho ophezulu. Ngalo mava obuchwepheshe esinawo emva kweminyaka elishumi, sinikezela nge-ESS yekhabhathi yangaphandle eyenziwe ngokweemfuno zomthengi, ii-inverters zasekhaya kunye nezisombululo zamandla eziphathwayo kubathengi behlabathi jikelele.
WhatsApp/Wechat: +852 59811073

Fumana isisombululo sakho seMegSolid sokugcina amandla kwiiyure ezingama-24.

Ngqo kumvelisi weebhetri ze-solid-state. Fumana isiphakamiso se-ESS esenziwe ngokweemfuno zakho, uhlalutyo lwe-ROI, kunye nesindululo senkqubo kwiqela lethu lobunjineli.

Into Oza Kuyifumana

Ityelelwe ehlabathini lonke:

UL, IEC, UN38.3, China Classification Society, GB36276-2023, RoHS

Iimodeli ezishushu:

Izicelo:

Iifektri · Iifama zelanga · Ezemigodi · IiZiqithi · Iziko leDatha

Sixelele ngeprojekthi yakho — siza kukuyilela inkqubo.