This G2S-C single-phase energy storage inverter is part of the REVO residential energy storage inverter series. It supports on-grid/off-grid AC coupling, three-phase connection and parallel operation of multiple units. Equipped with intelligent load management and remote BMS upgrade functions, it is available in multiple versions including models without color screen, with color screen and with generator input. With a power range from 4.5kW to 9kW, it is well-suited for household energy storage applications.

IP65

Indringersbeskerming

LCD

Display

<3%

THDi

Rated grid voltage (V)

230

Grid voltage range (V)

176~270

Grid input voltage (V)

230

Rated grid frequency (Hz)

PV input data

Ons Kernwaardes

PV input data

Model

R3KL1DA-G2S-C | R3K6L1DA-G2S-C | R4KL1DA-G2S-C | R4K6L1DA-G2S-C | R5KL1DA-G2S-C | R6KL1DA-G2S-C

Maks. PV-insetkrag (kW)

4.5 | 5.4 | 6 | 6.9 | 7.5 | 9

Max. PV-ingangsspanning (V)

550

Aanskakelspanning (V)

100

MPPT-spanningsbereik (V)

100~430

Rated PV input voltage (V)

360

Aantal MPPT-opspoorders

2

No. of strings per MPPT tracker

1/1

Maks. insetstroom per MPPT (A)

16/16

Max. short-circuit current per MPPT (A)

24/24

Battery input data

Battery tipe

Lithium-ion / Lead-acid

Max. charge / discharge power (kW)

3 | 3.68 | 4 | 4.6 | 5 | 6

Batterijspanningsbereik (V)

40~58

Rated battery voltage (V)

48

Max. charging / discharging current (A)

60/60 | 72/72 | 80/80 | 92/92 | 100/100 | 120/120

Rated charge / discharge current (A)

60/60 | 72/72 | 80/80 | 92/92 | 100/100 | 120/120

Battery charging strategy

Self-adaption to BMS

BMS communication

CAN

AC output data (grid side)

Rated output power (kW)

3 | 3.68 | 4 | 4.6 | 5 | 6

Max. apparent output power (kVA)

3.3 | 3.68 | 4.4 | 4.6 | 5 | 6.6

Max. apparent input power(kVA)

3.3 | 3.68 | 4.4 | 4.6 | 5 | 6.6

Grid frequency range(Hz)

47~61

Rated output current (A)

13 | 16 | 17.4 | 20 | 21.7 | 26.1

Max. AC output current (A)

14.3 | 16 | 19.1 | 20 | 21.7 | 28.7

Max. apparent input current (A)

14.3 | 16 | 19.1 | 20 | 21.7 | 28.7

Kragfaktor

>1 (0.8 leading ~ 0.8 lagging)

Max. grid passthrough current(A)

19.56 | 24 | 26.08 | 30 | 32.6 | 39.1

Grid type

L+N+PE

AC output data (back-up)

Rated output power (kW)

3 | 3.68 | 4 | 4.6 | 5 | 6

Max. apparent output power (kVA)

3.3 | 3.68 | 4.4 | 4.6 | 5 | 6.6

Rated output voltage (V)

230

Rated output frequency (Hz)

50/60

Rated output current (A)

13 | 16 | 17.4 | 20 | 21.7 | 26.1

Max. AC output current (A)

14.3 | 16 | 19.1 | 20 | 21.7 | 28.7

Peak output power

≥110%, 10mins; ≥120%, 1min; ≥130%, 1s; ≥150%, 100ms

Back-up switch time (ms)

<20

THDu

<3%

Kry jou MegSolid-energiebergingsoplossing binne 24 uur

Direk van 'n Vastestaat-batteryvervaardiger. Ontvang 'n pasgemaakte ESS-voorstel, ROI-ontleding en stelselaanbeveling van ons ingenieurspan.

Wat jy sal ontvang

Wêreldwyd Vertrou

UL, IEC, UN38.3, China Klassifikasiesamesetting, GB36276-2023, RoHS