تحميل ملف المواصفات التقنية (PDF)

This G2S-C single-phase energy storage inverter is part of the REVO residential energy storage inverter series. It supports on-grid/off-grid AC coupling, three-phase connection and parallel operation of multiple units. Equipped with intelligent load management and remote BMS upgrade functions, it is available in multiple versions including models without color screen, with color screen and with generator input. With a power range from 4.5kW to 9kW, it is well-suited for household energy storage applications.

IP65

حماية الدخول

LCD

Display

<3%

THDi

Rated grid voltage (V)

230

Grid voltage range (V)

176~270

Grid input voltage (V)

230

Rated grid frequency (Hz)

PV input data

قيمنا الأساسية

PV input data

نموذج

R3KL1DA-G2S-C | R3K6L1DA-G2S-C | R4KL1DA-G2S-C | R4K6L1DA-G2S-C | R5KL1DA-G2S-C | R6KL1DA-G2S-C

أقصى قدرة إدخال للطاقة الكهروضوئية (كيلوواط)

4.5 | 5.4 | 6 | 6.9 | 7.5 | 9

Max. PV input voltage (V)

550

جهد البدء (فولت)

100

نطاق جهد تتبع نقطة القدرة القصوى (فولت)

100~430

Rated PV input voltage (V)

360

عدد أجهزة التتبع MPPT

2

No. of strings per MPPT tracker

1/1

الحد الأقصى لتيار الدخل لكل وحدة MPPT (أمبير)

16/16

Max. short-circuit current per MPPT (A)

24/24

Battery input data

نوع البطارية

Lithium-ion / Lead-acid

Max. charge / discharge power (kW)

3 | 3.68 | 4 | 4.6 | 5 | 6

نطاق جهد البطارية (فولت)

40~58

Rated battery voltage (V)

48

Max. charging / discharging current (A)

60/60 | 72/72 | 80/80 | 92/92 | 100/100 | 120/120

Rated charge / discharge current (A)

60/60 | 72/72 | 80/80 | 92/92 | 100/100 | 120/120

Battery charging strategy

Self-adaption to BMS

BMS communication

CAN

AC output data (grid side)

Rated output power (kW)

3 | 3.68 | 4 | 4.6 | 5 | 6

Max. apparent output power (kVA)

3.3 | 3.68 | 4.4 | 4.6 | 5 | 6.6

Max. apparent input power(kVA)

3.3 | 3.68 | 4.4 | 4.6 | 5 | 6.6

Grid frequency range(Hz)

47~61

Rated output current (A)

13 | 16 | 17.4 | 20 | 21.7 | 26.1

الحد الأقصى لتيار الإخراج المتردد (أمبير)

14.3 | 16 | 19.1 | 20 | 21.7 | 28.7

Max. apparent input current (A)

14.3 | 16 | 19.1 | 20 | 21.7 | 28.7

Power factor

>1 (0.8 leading ~ 0.8 lagging)

Max. grid passthrough current(A)

19.56 | 24 | 26.08 | 30 | 32.6 | 39.1

Grid type

L+N+PE

AC output data (back-up)

Rated output power (kW)

3 | 3.68 | 4 | 4.6 | 5 | 6

Max. apparent output power (kVA)

3.3 | 3.68 | 4.4 | 4.6 | 5 | 6.6

Rated output voltage (V)

230

Rated output frequency (Hz)

50/60

Rated output current (A)

13 | 16 | 17.4 | 20 | 21.7 | 26.1

الحد الأقصى لتيار الإخراج المتردد (أمبير)

14.3 | 16 | 19.1 | 20 | 21.7 | 28.7

Peak output power

≥110%, 10mins; ≥120%, 1min; ≥130%, 1s; ≥150%, 100ms

Back-up switch time (ms)

<20

THDu

<3%

احصل على حل تخزين الطاقة MegSolid الخاص بك خلال 24 ساعة

مباشرةً من شركة مصنعة لبطاريات الحالة الصلبة. احصل على عرض مخصص لنظام تخزين الطاقة (ESS)، وتحليل العائد على الاستثمار، وتوصيات بشأن النظام من فريقنا الهندسي.

ما ستحصل عليه

موثوق بها في جميع أنحاء العالم:

UL، IEC، UN38.3، جمعية تصنيف السفن الصينية (CCS)، GB36276-2023، RoHS

عارضات أزياء مثيرات:

التطبيقات:

مصانع · مزارع شمسية · تعدين · جزر · مراكز بيانات

أخبرنا عن مشروعك لنقوم بتصميم النظام لك.

Seraphinite AcceleratorOptimized by Seraphinite Accelerator
Turns on site high speed to be attractive for people and search engines.