Le inverter yokugcina amandla yohlobo lwe-G2S-C enesigaba esinye yinxalenye yothotho lwee-inverter zokugcina amandla zasekhaya ze-REVO. Ixhasa ukuqhagamshelwa kwe-AC okungekho phantsi kwegridi/okukho phantsi kwegridi, uqhagamshelo lwezigaba ezithathu kunye nokusebenza ngokunxuseneyo kwee-yunithi ezininzi. Ifakwe ulawulo lobuxhobo olukrelekrele kunye nemisebenzi yokuphucula i-BMS ukude, ifumaneka ngeentlobo ezininzi eziquka iimodeli ezingenayo isikrini esinemibala, ezinesikrini esinemibala kunye nezo zingenayo ingeniso yejenereyitha. Inomlinganiselo wamandla oqala kwi-4.5kW ukuya kwi-9kW, ilungele kakhulu ukusetyenziswa ekugcineni amandla asekhaya.
Ipasi 65
Ukhuselo lwengeno
LCD
Ukubonisa
<3%
I-THDi
Rated grid voltage (V)
230
Grid voltage range (V)
176~270
Grid input voltage (V)
230
Rated grid frequency (Hz)
PV input data
Iinkcukacha zobuchwepheshe
PV input data
Umzekelo
R3KL1DA-G2S-C | R3K6L1DA-G2S-C | R4KL1DA-G2S-C | R4K6L1DA-G2S-C | R5KL1DA-G2S-C | R6KL1DA-G2S-C
Max. PV input power (kW)
4.5 | 5.4 | 6 | 6.9 | 7.5 | 9
Max. PV input voltage (V)
550
Start-up voltage (V)
100
MPPT voltage range (V)
100~430
Rated PV input voltage (V)
360
No. of MPPT trackers
2
No. of strings per MPPT tracker
1/1
Max. input current per MPPT (A)
16/16
Max. short-circuit current per MPPT (A)
24/24
Battery input data
Battery type
Lithium-ion / Lead-acid
Max. charge / discharge power (kW)
3 | 3.68 | 4 | 4.6 | 5 | 6
Battery voltage range (V)
40~58
Rated battery voltage (V)
48
Max. charging / discharging current (A)
60/60 | 72/72 | 80/80 | 92/92 | 100/100 | 120/120
Rated charge / discharge current (A)
60/60 | 72/72 | 80/80 | 92/92 | 100/100 | 120/120
Battery charging strategy
Self-adaption to BMS
Unxibelelwano lwe-BMS
CAN
AC output data (grid side)
Amandla omveliso alinganisiweyo (kW)
3 | 3.68 | 4 | 4.6 | 5 | 6
Max. apparent output power (kVA)
3.3 | 3.68 | 4.4 | 4.6 | 5 | 6.6
Max. apparent input power(kVA)
3.3 | 3.68 | 4.4 | 4.6 | 5 | 6.6
Grid frequency range(Hz)
47~61
Rated output current (A)
13 | 16 | 17.4 | 20 | 21.7 | 26.1
Max. AC output current (A)
14.3 | 16 | 19.1 | 20 | 21.7 | 28.7
Max. apparent input current (A)
14.3 | 16 | 19.1 | 20 | 21.7 | 28.7
Umlinganiselo wamandla
>1 (0.8 leading ~ 0.8 lagging)
Max. grid passthrough current(A)
19.56 | 24 | 26.08 | 30 | 32.6 | 39.1
Grid type
L+N+PE
AC output data (back-up)
Amandla omveliso alinganisiweyo (kW)
3 | 3.68 | 4 | 4.6 | 5 | 6
Max. apparent output power (kVA)
3.3 | 3.68 | 4.4 | 4.6 | 5 | 6.6
Rated output voltage (V)
230
Rated output frequency (Hz)
50/60
Rated output current (A)
13 | 16 | 17.4 | 20 | 21.7 | 26.1
Max. AC output current (A)
14.3 | 16 | 19.1 | 20 | 21.7 | 28.7
Peak output power
≥110%, 10mins; ≥120%, 1min; ≥130%, 1s; ≥150%, 100ms
Back-up switch time (ms)
<20
I-THDu
Ngaphantsi kwe-3%