Khuphela iPDF yezichazi zobuchwepheshe

Uluhlu lweeNqaku zeBESS SCADA: Into Ekufuneka i-EMS Yakho Ithumele

Injineli yakwa-MegSolid ejonga uluhlu lweendawo ze-BESS SCADA lwe-EPC RFQ kunye nokwamkelwa kwe-FAT

I-MegSolid icebisa ukuba uluhlu lweepoyinti ze-BESS SCADA luthathwe njengento ekufuneka ihanjiswe ngokwesivumelwano, hayi njengokuthunyelwa kwerejista okuceliweyo ngexesha lokuqaliswa kokusebenza. Ukuba i-RFQ ayizichazi iimetriki ezifunekayo, iimeko, izilumkiso, imiyalelo kunye ne-metadata, i-EPC isenokufumana amakhulu e-tags kodwa isenokungabi nazo iisignali ezimbalwa ezifunekayo ukuze isebenze, ihlole kwaye yamkele isityalo.

Impendulo ethe ngqo kukuba kuvunywe uluhlu lwamanqaku olulodwa phambi kwe-FAT oludibanisa ithegi nganye kwisixhobo sayo somthombo, intsingiselo yobunjineli, uhlobo lwedatha, iiyunithi, isikali, iflegi yomgangatho, umgaqo-nkqubo wohlaziyo, imvume yokufikelela, indlela yokusingatha i-alam kunye novavanyo lokwamkelwa. Le ndlela inika injineli ye-SCADA ujongano olunokwakhiwa kwaye inika isebe lezothengo uxanduva lomthengisi olunokulinganiswa.

Impendulo eto ngqo: Yenza uluhlu lwezinto ezibalulekileyo lube sisivumelwano sesikhokelo.

Uluhlu oluluncedo lweendawo ze-BESS SCADA luyinto engaphezulu koluhlu lweedilesi ze-Modbus. Ichaza into enokubonwa ngumqhubi, into enokuyalelwa yi-EMS, into esaphantsi kwegunya lokukhusela le-BMS okanye i-PCS, kunye nobungqina obuya kungqina ukuba ujongano ngalunye lusebenza. I- Isikhokelo sesakhiwo sonxibelelwano se-BMS ne-EMS Ichaza iileya zenkqubo; eli phepha linombuzo owahlukileyo wokufunyanwa kwezinto malunga nokuba yintoni kanye ekufuneka ihanjiswe phakathi kwazo.

Le ndlela yokwakha isalathiso ibonakalisa indlela yokwenene yokufunyanwa kweenkonzo eziluncedo. Umda we-Xcel Energy BESS EMS izicelo zeeluhlu lwamanqaku ze-EMS ne-RTAC, imizobo yonxibelelwano, izicwangciso ze-FAT ne-commissioning. Isifundo sokufumana iimpahla silula: uluhlu lwamanqaku lufanele lube kwiphakheji yoyilo, hayi kuluhlu lokugqibela lweziphoso lwe-commissioning.

Umyalelo wesignali ye-BESS-to-SCADA obonisa i-telemetry, igunya lokuyalela le-EMS kunye nezilawuli zokhuseleko zasekuhlaleni

Qala ngeeQela leeNqaku eziThandathu, hayi ngoKuthunyelwa kweRejista okungacwangciswanga.

Iqela elincinci lamanqaku kufuneka lilungelelaniswe ngokwesigqibo esixhaswa liqela ngalinye ledatha. Imephu yeregistrha ekrwada isenokubonisa amawaka exabiso, kodwa ayixeleli i-EPC ukuba zeziphi iindawo ezifanele zibekwe kwi-HMI yomsebenzisi, kwi-historian, kwingxelo yokusebenza okanye kwi-control loop. Sebenzisa la maqela alandelayo njengesiseko se-RFQ, uze wongeze iimfuno ezikhethekileyo zeprojekthi zegridi, tarifi kunye nabathengi.

Iqela le-pointImizekelo esisisekoIsigqibo sixhaswe
I-PCC kunye nokulinganisa kwesizaUkungenisa/ukuthumela ngaphandle kwe-kW, kvar, ivoltheji, i-current, i-frequency, i-power factor, i-kWh engenisiweyo/ethunyelwe ngaphandle, umgangatho wemithaQinisekisa utshintshiselwano lwegridi, umda wokuhlawulelana kunye nempendulo ye-EMS
Isishwankathelo somzi-mveliso we-BESSIzibali zamandla okutshaja/okukhupha, amandla okwenene, i-SOC, i-SOH, imowudi yokusebenza, ukufumaneka kunye nontlawulo yamandla iyonkeYazi ukuba isityalo sinokunika ntoni ngoku nokuba kutheni sinokuba nemida.
Ujongano lwe-PCS ne-ACI-voltage ne-current ye-AC/DC, i-kW, i-kvar, i-frequency, i-power factor, imeko yokusebenza, imeko yempazamo, isetpoint kunye ne-feedbackQinisekisa impendulo yokuguqulwa kunye nemeko yokusebenza kombane
Ibhetri kunye ne-BMSSOC, SOH, ivoltage/i-current ye-DC, imida yokutshaja/yokukhupha, amaqondo obushushu aphezulu/ezantsi, imeko ye-insulation kunye nee-alam ezisebenzayoHlonipha imida yebhetri kwaye uhlolisise ukuncitshiswa kwamandla.
Abancedisi nokhuselekoImeko yokupholisa, iqondo lobushushu lekhabhathi, isishwankathelo sephaneli yomlilo, imeko yomsi/yegesi apho ifakiweyo, umqobo kaxakeka kunye nempilo yomthombo oncedisayoChaza iimeko ezinokunciphisa amandla okanye zime isixokelelwano.
Umlawuli kunye nenethiwekhiImowudi ye-EMS, isilwanyana ekujoliswe kuso, umthombo womyalo, imeko yasekuhlaleni/ekude, unxibelelwano lwesixhobo, ukulungelelaniswa kwexesha, iflegi yedatha endala kunye nempilo yomlawuliNgqina ukuba nguwuphi umlawuli onegunya nokuba ingaba iingeno zawo zisemthethweni na.

Musa ukukopa yonke ingongoma yomgangatho weseli kwi-site SCADA ngaphandle kwesizathu sokusetyenziswa. Gcina isishwankathelo somgangatho womqhubi kusetyenziso oluqhelekileyo kwaye uchaze indlela yokuxilonga eyahlukileyo yomodyuli okanye yophando lweseli xa isixhobo sikuxhasa oko. Le Iimodeli zokugcina amandla zeSunSpec Yibonise indlela iinkcukacha zebhanki, zomtya kunye nemodyuli ezinokubekwa ngokwamaleko kunokuba zidityaniswe kuluhlu olunye olungalawulwayo.

Nika i-SCADA Tag nganye iMetadata efunekayo ukuze isetyenziswe.

Igama le-tag elifana ne-Battery_Power alicacanga de umda walo kunye nemigaqo yophawu zicacisiwe. Ingaba ilinganiswa kwi-DC bus, kwii-terminals ze-PCS AC, kwi-LV board okanye kwi-PCC? Ingaba ixabiso elihle lithetha ukutshaja okanye ukukhupha i-charge? Ingaba ilinganiswa, ibalwa okanye iyalelwa? Ezo mibuzo kufuneka zisonjululwe kumgca ofanayo woluhlu lwamanqaku oluvunyiweyo.

Kwiiprojekthi ezinemiqathango yokuthunyelwa kumazwe angaphandle, uluhlu lwee-SCADA points kufuneka luxhase iimfuno zemitha, umyalelo, imeko, ixesha lokuphelelwa kunye ne-alam ezichaziweyo kwi Isakhelo solawulo lwe-EMS sokungathumeli ngaphandle.

Inkcukacha efunekayoIsizathu sokuba kubalulekeIsigqibo somzekelo
Isixhobo esikhethekileyo nesomthomboIthintela amagama aphindaphindiweyo kwaye ichaza umnini wedatha.I-PCC meter kW ayifani ne-PCS kW.
Idilesi, iprotocol kunye nohlobo lwedathaYivumela i-integrator ukuba yakhe kwaye ivavanye imephu.Isigcini-regista, iregista yokufaka, ibithi, i-float okanye inani elipheleleyo
Iiyunithi, isikali kunye nophawuIthintela iimpazamo eziphindwe ngokuphindwe kalishumi kunye neempazamo zendlela ephambukileyo.i-kW xa ithelekiswa ne-W; ukukhupha umbane omhle xa kuthelekiswa nokutshaja ngombane omhle
Uluhlu nexabiso elingasebenziyoIxhasa ukuqinisekiswa kwaye iyakwala idatha eyonakeleyo.Umlinganiselo wobunjineli ovunyiweyo nekhowudi yedatha engenakufumaneka
Uhlaziyo, isiqingatha esingasebenziyo kunye nesitampu sexeshaIlungelelanisa ulawulo, i-HMI kunye nokusebenza kwe-historianUhlaziyo oluqhutywa sisiganeko okanye oluqhelekileyo olunempawu yexesha yomthombo
Ugunyazi lokufunda nokubhalaIthintela iindawo zokubeka iliso ukuba zingajiki zibe yimiyalelo engalawulekiyoFunda kuphela, umsebenzisi ubhale okanye ilawulwe yi-EMS
Ukuphathwa kwezilumkiso ngokwezinga nokubambelelaYenza ii-alam zibe luncedo endaweni yokuba zibe nengxolo nje.Isilumkiso, ingozi, imeko kaxakeka; ukuzicima okanye ukusetwa ngesandla
Isalathiso se-FAT/SATIdibanisa umgca wedatha nobungqina bokwamkelwa ngenjongo.Inyathelo lovavanyo, isiphumo esilindelekileyo kunye nendlela ehamba ngayo
Itemplate yoluhlu lweepoyinti ze-BESS SCADA enamathegi, imithombo, umgangatho wedatha, iialarm kunye neendawo zovavanyo lwe-FAT.

Uhlukaniso lokuBeka iliso, iMyalelo kunye neGunya loKhuseleko

Uluhlu lweepoyinti ze-SCADA kufuneka lubonise ukuba zeziphi iinqobo ezingolwazi, zeziphi iiyalelo ezinokubhalwa, nokuba zeziphi izigqibo zokukhusela ezihlala zikwindawo kwi-BMS, i-PCS, inkqubo yomlilo okanye isekethe edityaniswe ngokungqindilili. I-tag enokubhalwa ayisiyongqeqesho yokuyilawula ngokuzenzekelayo. Ingxelo yolawulo, i-interlock matrix kunye noyilo lokufikelela komsebenzisi kufuneka zihambelane noluhlu lweepoyinti.

Musa ukuqikelela ukuba iprotocol enye yenza izixhobo zisebenzisane. I-Modbus ingamisa umgangatho wokuthuthwa, ngelixa iprojekthi isadinga imodeli yedatha evunyelweneyo, ukukhulisa, igunya lolawulo kunye nendlela yokuphatha iziganeko ezingaqhelekanga. Phambi kokukhetha izixhobo, sebenzisa iMegSolid's Isikhokelo sokufumana indawo yokugcina amandla orhwebo kwaye Uluhlu lokujonga olufanelekileyo lwababoneleli be-BESS Ukugcina amaxwebhu onxibelelwano ngaphakathi kothelekiso lwexabiso.

Sebenzisa iLuhlu loHlolo kwii-Interfaces zeMegSolid Product.

IMegSolid ipapasha izidibanisi zonxibelelwano ezizodwa kwimodeli ezinokusetyenziswa ukuseka imida ye-RFQ. Ezi zinto azithathi ndawo yomephu yerhjisitha eyalwayo, uhlaziyo lwe-firmware kunye novavanyo lokudityaniswa. Umthengi kufuneka acele ezo zixwebhu zilawulwayo zemodeli echanekileyo kunye nophuhliso lweprojekthi.

Usapho lweMegSolidIi-interface ezipapashiweyoIsenzo se-RFQ
ESSA yangaphandle uthotho lwe-C&IRS485 ne-TCP-IP; i-EMS edityanisiweyo; i-LCD ephathekayo neqonga le-cloud; ukufikelela ngaxeshanye kumthwalo, ibhetri, ingridi, ijeneretha yedizili kunye ne-PVCela uluhlu lwezinto ezilandelelanisiweyo ze-EMS, imephu yesixhobo somthombo, imiyalelo enokubhalwa, uluhlu lwe-alam kunye nenkqubo ye-FAT.
MEGA0030TS–MEGA0500TS PCSBMS nge-RS485/CAN; EMS nge-RS485/TCP-IPChaza umda wobunini be-PCS/BMS/EMS kwaye uqinisekise imephu yombhalisi yomgangatho wemodeli.
PMA080–PMA0125 PCS yemodyuliRS485, CAN ne-Ethernet; izixhumi ze-BMS ne-EMSQinisekisa ukwabiwa kweprotocol, umda wegateway kunye neembopheleleko zokudityaniswa kwe-transformer/necandelo.
I-inverter ehlanganisiweyo ye-R30KH3–R50KH3I-Mitha RS485; i-BMS RS485/CAN; i-EMS RS485Yahlula idatha yomlinganiselo womzila, ibhetri kunye nomlawuli wendawo, kwaye uvume igunya lomyalo

Kwisicelo se-C&I sangaphandle se-30–100 kW, 55.296–215.04 kWh, jonga uphononongo lwe- Iqonga langaphandle leMegSolid ESSA lokugcina amandla kunye ne Isikhokelo sokukhetha i-BESS ye-100 kW / 215 kWh. Kwiimida ezinkulu ze-PCS, thelekisa i I-MEGA TS PCS enetransformer yokwahlula kunye ne Uluhlu lwePCS zePMA ezimoduli.

Iqonga le-ESSA lingalungiselelwa ngeeseli zebhetri ze-solid-state ukuhlangabezana neemfuno ezithile zeprojekthi, kodwa olu khetho kufuneka luqinisekiswe kwikowuteshini, kwiphepha ledatha elisayiniweyo nakwi-BOM. Xa ixhaswe bubungqina bovavanyo lwekhontrakthi, ulungelelwaniso olungqiniweyo lwe-solid-state hybrid lunokuvavanywa ukuze kuphuculwe uzinzo lobushushu okanye kuncitshiswe iingozi ezithile; ayisusiyo ingxaki yokuphuma kobushushu (thermal runaway) kwaye akufuneki inciphise ubushushu obufunekayo, umda we-BMS, ukufunyanwa komlilo, ukuvalwa kunye nokubeka iliso kunxibelelwano. Jonga i Iinketho zokugcina amandla zeMegSolid ezingaguqukiyo kunye ne Isikhokelo sokuqinisekisa ukuphuma kobushushu obugqithisileyo kwibhetri ye-solid-state yomda wokhuseleko olungileyo kwinqanaba lenkqubo.

Yila iDatha ye-Alarm nezeSiganeko ukuze kusetyenziswe amanyathelo, hayi ivolyum.

Uluhlu lwezilumkiso oludlulisela sonke isiganeko sesixhobo ngokwaluhlu olunye lwezinto eziphambili luza kubatyhafisa abasebenzi kwaye lufihle isiganeko esibalulekileyo. I-RFQ kufuneka ifune ifilosofi yezilumkiso enika ubunzima, unobangela, isenzo somsebenzisi, ukubambelela, isiqinisekiso, igunya lokuseta kwakhona kunye nemigaqo yokucinezela. Isilumkiso ngasinye esiphambili kufuneka sikwabonise imeko yokusebenza ehambelanayo kunye nasiphi na isimo sokuphendula esizenzekelayo.

Iimfuno zokuhamba komkhwa kufuneka zicaciswe ngokufanayo. Chaza ukuba zeziphi iindawo ezifuna iimvuthuluka zexesha zomthombo, iirekhodi zokucombulula iziganeko, ukufunxa kwexesha elifutshane okunokucacisa okuphezulu kunye nogcino lwexesha elide lwembali. Iimfuno ze-AES Indiana SCADA Nika umzekelo oluncedo wokufumana idatha ngokucela igama lephoyinti, idilesi, inkcazelo, ubude, iiyunithi, i-offset kunye nohlobo lwedatha endaweni yokwamkela idumpi yerhijista engenaziphawu.

Yenza i-FAT ne-SAT zingqine lonke uthotho lweenkcukacha

Ukuvunywa koluhlu lwezinto akungqini ukudityaniswa. I-FAT kufuneka ikhuthaze okanye yenze umfanekiso wexabiso lomthombo, iqinisekise imephu ye-EMS kwaye ibonise isiphumo esichanekileyo se-SCADA. I-SAT kufuneka iphinde iimvavanyo ezibalulekileyo kuyo yonke inethiwekhi efakiweyo, iimitha zokugqibela, iimvume zabasebenzisi kunye nolawulo lwesiza olulandelelanayo. Sebenzisa i- Isikhokelo sovavanyo lokwamkelwa kwemveliso yefektri yeBESS Ukudibanisa imigca yoluhlu lwamanqaku nobungqina obungqiniweyo.

Uvavanyo lokwamkelwaUbungqina obufunekayoUkusilela okuqhelekileyo kufunyenwe
Idilesi nobuniIsixhobo somthombo, irejista kunye nethegi ye-SCADA ziyangqinelana noluhlu oluvunyiweyo.Isixhobo esingachanekanga okanye ithegi ephindwe kabini
Isikali nophawuIxabiso elifakweyo elaziwayo liyavela kunye neeyunithi ezichanekileyo kunye nendlela.Impazamo yokukhulisa ephindwe ka-10 okanye uphawu lokutshaja olujikisiweyo
Idatha esemgangathweni nephungileyoUkunqamka konxibelelwano kuyatshintsha umgangatho, kuphakamisa isilumkiso esivunyiweyo kwaye kuthintela ukusetyenziswa kolawulo olungekho mthethweni.Ixabiso eliqandisiweyo liboniswa njengelilungileyo
Umyalelo nempenduloIsicelo esigunyazisiweyo siqwalaselwa ukuba sikwizinga elivumelekileyo, siqinisekiswe, kwaye sithelekiswe nempendulo yokwenene.Umyalelo wamkelwe kwiscreen kodwa awunanzwanga sisixhobo.
Ulandelelwano lwe-alamI-Timestamp, i-priority, i-first-out, i-acknowledgement, i-clear kunye ne-reset zisebenza njengoko kuchaziwe.Inkxalabo: Kwisikhukula okanye kusilele isiganeko esiqalisayo
Ukufunyanwa kombhali-mbaliIirekhodi zentsingiselo neziganeko zingathunyelwa ngaphandle ngexesha lovavanyo oluvunyelweneyo.Idatha iyabonakala ngqo kodwa ayifumaneki njengobungqina bokwamkelwa
Igunya nokufikelelaImeko yasekuhlaleni/ekude kunye nendima yomsebenzisi zivumela kuphela ukubhala okuvunyiweyo.Abalawuli abangquzulayo okanye iimvume zomsebenzisi ezigqithisileyo

Faka ezi zinto ze-SCADA kwi-EPC RFQ.

Ixabiso elinikiweyo kufuneka lichaze kungekuphela nje isikhululo sonxibelelwano, kodwa kwanezo zoncwadi zobunjineli kunye nemisebenzi yokudibanisa ebandakanyiweyo kwixabiso. Oku kuthintela umthengisi webhetri, umthengisi we-PCS, umdibanisi we-EMS kunye nosonkontileka we-site-SCADA ekubekeni elinye iqonga elingekhoyo omnye komnye emva kokuba izixhobo zifikile.

Ukuze ufumane i-Template ye-MegSolid BESS SCADA Point-List enokulungiswa, thumela i-imeyile. [email protected]. Bandakanya ilizwe leprojekthi, i-SLD, amandla kunye namandla e-BESS afunekayo, imodeli ekhethiweyo okanye ecetywayo, ivoltheji ye-PCC, iqonga le-SCADA/PLC, iprotocol ekhethwayo, iinkcukacha zemitha ekhoyo kunye nezilawuli zasiza, iindlela zokusebenza ezifunekayo, ifilosofi ye-alam, umda we-FAT/SAT kunye neshedyuli yokuhanjiswa. IMegSolid ingakwazi ke ukuhlola umda wendawo yokudibana phambi kokuba ikowuteshini ibe yingxaki yokuqalisa ukusebenza.

Imibuzo Ebuzwa Rhoqo

Kufuneka iqulathe imilinganiselo, iimeko, izilumkiso kunye nemiyalelo evunyiweyo, kunye nesixhobo somthombo, idilesi, uhlobo lwedatha, iiyunithi, isikali, isivumelwano sesalathisi, uluhlu, umgaqo womgangatho, indlela yokuhlaziya, igunya lokufikelela, unyango lwezilumkiso kunye nesalathiso se-FAT/SAT kuyo yonke inqaku.

Umthengisi ngamnye wezixhobo kufuneka abonelele ngemephu yayo yombhalisi elawulwayo kunye nee-alamu. Umdibanisi we-EMS okanye we-SCADA kufuneka adibanise ezo zixhobo zokufumana ulwazi zibe kuluhlu olunye lweendawo zokufumanisa ulwazi kwinqanaba lesiza, ngelixa i-EPC okanye umnini-ndawo evuma iimfuno zokuthiywa kwezinto, igunya, umgcini-mbali kunye nokwamkelwa.

Akukho nani lulodwa elisebenzayo kuyo yonke indawo. Inani elifunekayo lixhomekeke kubukhulu besixokelelwano, inani lezixhobo, inqanaba lokunika ingxelo, ubunzulu bokuxilonga, iindlela zokusebenza kunye nezibophelelo zekhontrakthi. Chaza kuqala izigqibo ezifunekayo, uze emva koko ukhethe iindawo ezizixhasayo.

Kufuneka kubhalwe kuphela imiyalelo evunyiweyo kwibali lolawulo. Ngamnye ufuna uluhlu olusebenzayo, igunya lomsebenzisi, umgangatho womthombo, izitshixo-zokunxibelelana, isiqinisekiso, ingxelo yempendulo yokwenene kunye nokuziphatha okucacisiweyo xa isicelo asamkelwanga okanye unxibelelwano luyasilela.

Akusoloko kunjalo. Imisebenzi eqhelekileyo isenokufuna izishwankathelo zebhanki okanye zomtya, ngelixa idatha ekumgangatho weseli isenokugcinelwa ukuhlolwa kwezifo. Chaza umbono womsebenzisi, iimfuno zomgcini-mbali kunye nokufikelela kwenkonzo ngokwahlukeneyo ukuphepha ubungakanani obungeyomfuneko beethagi.

Imephu yobhaliso ichaza idatha eveliswe sisixhobo. Uluhlu lwamanqaku e-SCADA lukhetha amanqaku afunekayo kwiprojekthi kwaye longeza intsingiselo yobunjineli, amagama, iimvume, indlela yokusebenza kwe-alam, imigaqo yokuhlaziya, ubunini kunye nemiqathango yokwamkelwa.

Yahlula ii-alam ngokweziphumo zokusebenza kunye nentshukumo efunekayo, uze uchaze ukubambelela, isiqinisekiso, ukusetwa ngokutsha kunye nokucinezelwa. Iziganeko zokuqhuma okanye ezingxamisekileyo, ukuncitshiswa komthamo okukhulu, izilumkiso kunye neengcebiso akufuneki zabelane ngolona luhlu lwezinto eziphambili olunye olungahlukanga.

Vuma uluhlu lwamanqaku, isakhiwo sesixhobo nenethiwekhi, iimephu zokubhalisa, uluhlu lwe-alam, ingxelo yolawulo, uluhlu lwamanyathelo olawulo, indlela yokulungelelanisa ixesha, iimfuno zomgcini-mbali, iindima zabasebenzisi kunye nenkqubo ye-FAT phambi kokuba kuqalwe uvavanyo olubonwe ngamangqina.

Faka okanye wenze umfanekiso wexabiso elaziwayo lomthombo, ulilandele kwi-gateway okanye kwi-EMS, uqinisekise i-SCADA tag, iiyunithi, isikali, uphawu, umgangatho kunye ne-timestamp, uze urekhode isiphumo kwilayini yeluhlu lwamanqaku evunyiweyo.

I-ESSA series ipapasha i-RS485 kunye ne-TCP-IP; i-MEGA TS ipapasha i-BMS RS485/CAN kunye ne-EMS RS485/TCP-IP; i-PMA ipapasha i-RS485, i-CAN kunye ne-Ethernet; I-R30KH3–R50KH3 ipapasha ii-interface ezahlukileyo zemitha, i-BMS kunye ne-EMS. Cela imephu enembileyo yorejista yemodeli phambi kokuyila.

Uluhlu lwezinto ze-BESS SCADA luludwe oluvunyiweyo lwemilinganiselo yokugcinwa kwebhetri, iimeko, izilumkiso kunye nemiyalelo etshintshiselwana phakathi kwesixhobo sasentsimini, i-EMS kunye ne-SCADA yendawo, kuquka i-metadata efunekayo ukutolika nokuvavanya into nganye.

I-EMS iqokelela idatha evunyiweyo kwimitha, i-BMS, i-PCS kunye neenkqubo zokuncedisa, isebenzise imodeli yedatha yeprojekthi kwaye idlulise amaxabiso akhethiweyo, iimeko kunye nee-alam ngenkqubo yoshishino evunyelweneyo. Ii-odolo zibuya kuphela ngendlela egunyazisiweyo yokugunya.

Thumela i-SLD, i-BESS kW ne-kWh, imodeli ecetywayo, i-voltage ye-PCC, iqonga le-SCADA okanye le-PLC, iprotocol ekhethwayo, iinkcukacha zemitha nesilawuli, iindlela zokusebenza, iindawo ezifunekayo, ifilosofi ye-alam, umda we-FAT/SAT kunye neshedyuli yokuhanjiswa.

IMegSolid (Hong Kong) Limited igxile kuphando nophuhliso, uyilo kunye nokubonelela ngeenkqubo zokugcina amandla ezikumgangatho ophezulu. Ngalo mava obuchwepheshe esinawo emva kweminyaka elishumi, sinikezela nge-ESS yekhabhathi yangaphandle eyenziwe ngokweemfuno zomthengi, ii-inverters zasekhaya kunye nezisombululo zamandla eziphathwayo kubathengi behlabathi jikelele.
WhatsApp/Wechat: +852 59811073

Fumana isisombululo sakho seMegSolid sokugcina amandla kwiiyure ezingama-24.

Ngqo kumvelisi weebhetri ze-solid-state. Fumana isiphakamiso se-ESS esenziwe ngokweemfuno zakho, uhlalutyo lwe-ROI, kunye nesindululo senkqubo kwiqela lethu lobunjineli.

Into Oza Kuyifumana

Ityelelwe ehlabathini lonke:

UL, IEC, UN38.3, China Classification Society, GB36276-2023, RoHS

Iimodeli ezishushu:

Izicelo:

Iifektri · Iifama zelanga · Ezemigodi · IiZiqithi · Iziko leDatha