Indlela yokucacisa ulawulo lwe-BESS lokungathumeli kumgama kwi-PCC

I-MegSolid icebisa ukuba kucaciswe. Ulawulo lokungeniswa kwe-BESS njengomjikelo wolawulo olulinganisiweyo kwindawo yokudibanisa efanayo (PCC), hayi njengendawo nje yokukhetha kuluhlu lwe-inverter. Ikhontrakthi ye-EPC kufuneka ichaze apho amandla alinganiswa khona, yeyiphi idivayisi enokutshintsha umveliso we-PV nebhetri, kwenzeka ntoni xa isignali isilele, kwaye isiphumo siza kungqinwa njani ngedatha yasesizeni. Ngaphandle kwala mida, inkqubo inokubonakala isebenza ngesiqhelo ngelixa isasenza amandla abuyela umva ngexesha lomthwalo okanye utshintsho lwelanga.

Ulawulo lwe-MegSolid BESS lokungathumeli ngaphandle kwi-PCC yamandla elanga orhwebo kunye nokugcinwa kwebhetri

Impendulo eNgena Ngqo: Lawula Amandla oMnatha kwi-PCC

I-EMS kufuneka ilawule amandla asebenzayo alinganisiweyo kwi-PCC evunyiweyo ngokwe-target enye esayiniweyo. Phantsi kwesivumelwano esingumzekelo sokungenisa okunempumelelo, Ukungeniso lwe-PCC = umthwalo wesiza − isiphumo se-PV − ukukhupha i-BESS + ukutshaja i-BESS. Iprojekthi isenokusebenzisa enye indlela yokumela iimpawu, kodwa imitha, i-EMS, i-PCS, i-SCADA kunye nengxelo yovavanyo kufuneka zonke zisebenzise enye efanayo.

Indawo yezichasiseloKufuneka isigqibo phambi kwekowuteshini.Ubungqina buyafuneka ekunikezeleni
Indawo yokujongaUmda ochanekileyo we-PCC, wendawo yokujonga okanye wemitha yenkonzoI-SLD evunyiweyo, indawo ye-CT kunye nesazisi semitha
Ukuphumeza ukuthunyelwaZiro, ixabiso lokuthunyelwa ngaphandle elilinganiselweyo okanye ukuthand' ukungenisa okuvunywe yiprojekthiIshedyuli yezicwangciso kunye nentshayelelo elawulwayo esayiniweyo
I-asethi ezilawulwayoI-BESS PCS, i-PV inverter okanye isilawuli somzi-mveliso, kunye nayo nayiphi na imithwalo elawulekayoUmqulu wobunini bemiyalelo nonxibelelwano
Indlela yokuziphatha enentshukumoUkwenza isampulu, ukuhluza, i-deadband, i-ramp, ixesha lokuphelelwa, nokuchachaIifayile zokuhamba kwe-FAT ne-SAT ezine-stampu yexesha
Imeko ekhuselekileyoImpendulo evunyiweyo kumlinganiselo ongavumelekanga okanye kunxibelelwano olulahlekileyoIsilumkiso, umyalelo wokubuyela umva kunye nerekhodi yokubuyisela

Musa ukudibanisa ixabiso lesikrini nokusebenza okusemqathini wesivumelwano. Izikhokelo zolawulo lwe-export zahlula inkqubo engathumeliyo ngaphandle kwelizwe kwinkqubo ethumela ngaphandle ngokulinganiselweyo, kwaye iphatha ukuthunyelwa ngaphandle okungacetywanga ngexesha lotshintsho olukhawulezayo njengokuziphatha okwahlukileyo okumele kuvavanywe. I- Isakhelo esilinganiselweyo nesingalawuliyo sokuthunyelwa kweebhetri kumazwe angaphandle sisalathiso esiluncedo, kodwa amaxwebhu asebenzayo enkonzo kunye nokudibanisa kufuneka asathe gqala le projekthi.

Chaza imida yokuthumela ngaphandle engaphezulu, ethi yona ibe nomda, kunye nemida yokungenisa ngokwahlukeneyo.

Ezi zinto zisetyenziswayo zihlala zixutywe kunye kwi-RFQs nangona zisombulula iingxaki ezahlukeneyo. Umthengi obhala nje “akukho mandla abuyayo” ushiya umthengisi uqikelele ixabiso elivumelekileyo elizinzileyo, umda wethutyana, ixesha elithile kunye nendlela yokusabela ekulahlekelweni ngumlinganiselo.

Imfuneko yokusebenzaInto elawulwa yi-EMSImpazamo eqhelekileyo kuthengo
Akukho nto ithunyelwa ngaphandleIthintela ukuthunyelwa ngabom kwamandla asebenzayo kwindawo ekubekiswe isibonelelo kuyo.Ukuthatha ukuba unomathotholo kuthetha ukuba akukho ukuphambuka kwangoko phantsi kwesiganeko ngasinye.
Uthunyelwa ngaphandle olulinganiselweyoIgcina ukuthunyelwa kumda ophumeleleyo ongaphantsi okanye olingana nenani elivunyiweyo elingenguye zero.Ukusishiya isilinganisi, isithuba esiqhelekileyo okanye ukunyamezelwa kungachazwanga
Umda wokungenisa wegridiAmandla e-caps power angeniswa liziko evela kwinethiwekhi.Ukuthatha ulawulo lokungenisa njengomsebenzi ofanayo nokuthintela ukuthunyelwa ngaphandle
Ukusebenza okuzimeleyoIlawula i-microgrid eyahlulwe ngombane emva kokuba isivuli segridi sivulekile.Ukulindela umjikelo onganiki mandla ngaphandle oxhumene kwigridi ukuba uchaze i-islanding kunye nokudlulisa

Ukulandelelana kokusebenza kufuneka nako kucace gca. Ulawulo lokungathumeli ngaphandle luyimfuneko engu-PCC, ngelixa ugcino-mbuyekezo, ukunciphisa ixesha eliphezulu kunye nokutshaja ngelanga zizinto ezikhuphisanayo ngaphakathi komda webhetri oseleyo. Sebenzisa ezahlukeneyo Isakhiwo sonxibelelwano se-BMS ne-EMS ubunini besignali, kunye ne Isikhokelo se-solar ne-BESS enokulawulwa yempahla, amandla kunye neefestile zokuhambisa.

Beka iMitha Apho Inokubona Sonke Isiza

Umsinga ongathumeli kumgama uphelele kuphela kangangoko umda walo wokulinganisa uphelele. Ukuba umbhobho wokufaka i-PV osele ukho, umbhobho omtsha wokufaka i-BESS okanye inxalenye yomthwalo womzi-mveliso ukwimeko engaphandle kwemitha yokulawula, i-EMS inokulawula ixabiso elingachanekanga ngelixa imitha yombane isebenzayo irekhoda ukuthunyelwa kumgama. Kungoko i-SLD kufuneka ibonise yonke imithombo kunye nomthwalo ngokunxulumene nee-PCC CTs.

Isakhiwo sokulawula esingenamkhupho seMegSolid esidibanisa i-PCC meter, i-EMS, i-PV inverter kunye ne-BESS PCS

Umgaqo ofanayo womda uvela kwiMegSolid's Isikhokelo seBESS sezikhululo zokutshaja izithuthi zombane, apho i-PCC meter, i-site EMS, i-PCS/BMS kunye nomlawuli wezichaji zineemisebenzi eyahlukileyo. Iphepha elitsha le-zero-export linemfuneko yokuthumela umbane kwisixokelelwano esivaliweyo endaweni yokulinganisa ubungakanani bezichaji.

Bhala ibalana loLawulo oluValelweyo phambi kokuba ufake ikhowudi.

Ingxelo yokulawula kufuneka ichaze umjikelo omnye opheleleyo wokuskena nokusabela ngolwimi olucacileyo lobunjineli. Oku kuba sisiseko solungiselelo lwesoftware, uvavanyo lwe-interface kunye nokwamkelwa okusemthethweni. Ikwathintela usonkontileka we-PV, umthengisi we-BESS kunye nomdibanisi we-EMS ekucingeni ukuba elinye iqela liyingumnini weziphumo zokugqibela ze-PCC.

Ukuthambekela okuncinci kokungenisa okusemgangathweni weprojekthi kunokunciphisa ukudlula okuphindaphindiweyo kube phantse zibe zisi-zero, kodwa ayisosixa esisebenza kuyo yonke indawo. Imfuneko yombane, ukuchaneka kwemitha, ukuguquguquka komthwalo wendawo, impendulo yomlawuli kunye nefuthe lezorhwebo zizimisela isethingi yokugqibela. Okufanayo kuyasebenza kwixesha lokusabela kunye nokuthunyelwa okungacetywanga okuvunyelweyo: bhala amaxabiso amkelweyo kumaxwebhu eprojekthi endaweni yokukopa inani eliqhelekileyo kwesinye isithuba.

Apho ijeneretha yedizili isebenzisana nebhasi ye-AC nenkqubo yebhetri, i-EMS kufuneka ikwathintele i-PCS ekubuyiseleni amandla asebenzayo kwijeneretha. Jonga eyethu Isikhokelo solawulo segenerator yedizili i-BESS kulawulo lobunini, ukhuselo lomthwalo omncinci, i-fail-safe logic kunye novavanyo lokuphazamiseka kombane obuyela umva.

Chaza indlela yokuziphatha ekhuselekileyo kuyo yonke isignali eyonakeleyo.

Umjikelo ongathumeli ngaphandle nto ongagqibelelanga usebenza kuphela xa yonke iphakheji ye-Ethernet isempilweni. I-RFQ kufuneka ichaze ukufunyanwa kwedatha egugileyo, ukuphelelwa kwexesha lomyalo, ukubuyela emva kwengingqi kunye nokuchacha kulo lonke unxibelelwano lolawulo. Eyona mpendulo ikhuselekileyo ixhomekeke kwiprojekthi kuba ezinye izityalo zikwazi ukunciphisa i-PV kwingingqi ngelixa ezinye zixhomekeke kumlawuli ophakathi.

Imeko engaqhelekangaUmda wemigqaliselo efunekayoUbungqina bokwamkelwa
I-PCC meter ayisebenzi okanye iphelelwe lixeshaYeka ukusebenzisa ixabiso lokugqibela kwaye ungenele kwimeko ekhuselekileyo evunyiweyo yokungathunyelwa kumazwe angaphandle.Umgangatho we-flag, i-timeout, i-alarm kunye nendlela ye-PCC ephumayo
Uqhagamshelwano lwe-EMS ukuya kwi-BESS lulahlekileChaza ukubuyela umva kwendawo kwe-PCS nokuba ukukhutshwa kuthintelwe okanye kunqunyelweUkuphumla komyalelo, imowudi yasekhaya kunye namandla ebhetri okwenene
Ulawulo lwe-EMS-to-PV lulahlekileChaza umda oseleyo wokufunxa we-BESS kunye nokubuyela umva okuzimeleyo kwe-PV.Imeko yomyalo we-PV, umda ophezulu we-BESS kunye nesiphumo se-PCC
Ibhetri ikwisimo sokushaja esiphezulu okanye umda wokushaja ufikelelweYehlisa i-actuator yokutshaja uze ulandele ulandelelwano oluvunyiweyo lokunciphisa i-PV.Umda we-BMS, ulwabiwo lwe-EMS, impendulo ye-PV kunye ne-alam
Ukuqaliswa ngokutsha komlawuli okanye ilahleko yokulungelelaniswa kwexeshaSebenzisa ukuqaliswa okulawulwayo phambi kokubuyisela ukuthunyelwa okuzenzekelayo.Imeko yokuqalisa, izitampu zexesha ezihambelanisiweyo kunye nomkhwa wokuchacha ngokutyibilikayo

Musa ukusebenzisa “qhubeka nomyalelo wokugqibela” njengokhetho olungachazwanga oluzenzekelayo. Umyalelo wokukhupha owakudala unokukhokelela kumthumelo ngaphandle emva kokuba umthwalo wesiza unyamalele. Oku kupapashwe yi-EPRI Isishwankathelo sovavanyo lolawulo lwe-backfeed lwe-ESS iquka amanyathelo okulayisha nokuvelisa kunye novavanyo lwezaziso zesivamvo ezingaqhelekanga, ibonisa isizathu sokuba ukusebenza okuqhelekileyo kuphela kungobungqina obaneleyo.

Guqula i-Turn Zero-Export Control ibe ngoviwo be-FAT ne-SAT zokuphumelela/zokusilela

Inyathelo lasefektri kufuneka liqinisekise ulwahlulo oluvunyiweyo ngokusebenzisa imithombo efanisiweyo, imithwalo, iimeko ze-SOC kunye nokusilela kwezignali. Inyathelo laselayithi kufuneka liphinde iimeko ezibalulekileyo ngokusebenzisa i-PCC meter efakiweyo, i-CT wiring yokwenyani, inethiwekhi yokwenyani kunye nezixhobo ze-PV/BESS ezifakwe esebenzayo. Umfanekiso we-dashboard awuyondlelo yokudlula.

MegSolid BESS zero-export FAT ne SAT iimvavanyo ze-load steps, i-PV steps kunye nokulahleka kwemitha ye-PCC

Sebenzisa iMegSolid's Isikhokelo sovavanyo lokwamkelwa kwemveliso yefektri yeBESS ukuchaza umda wangaphambi kokuthunyelwa oqinisekisiweyo. Ishedyuli yokuthumela engaphandle enezinga elingaphantsi kufuneka ke yongeze iziganeko ezikhethekileyo ze-PCC, umda wokwamkeleka, ixesha lovavanyo, ukuchaneka kwezixhobo zokulinganisa, umqinisekisi onoxanduva kunye noxanduva lokuphinda kuvavanywe.

Lungelelanisa i-Control Boundary ne-MegSolid ESSA Platform

I- Iqonga leMegSolid ESSA langaphandle le-C&I BESS Yintsapho yemveliso ethe ngqo yesi sisetyenziso. Idatha yayo elawulwayo yemveliso ibalisa iimodeli ze-AC ezinamandla angama-30–100 kW, iinkqubo zamandla ezilinganisiweyo eziyi-55.296–215.04 kWh, unxibelelwano lwe-RS485 ne-TCP-IP, imisebenzi ye-EMS edityanisiweyo, uqikelelo lwamandla kunye nexesha lokukhupha umbane, kunye nokufikelela ngaxeshanye kumthwalo, ibhetri, igridi, ijeneretha yedizili kunye ne-PV.

Iitheyibhile zoluntu ze-ESSA zichonga iiseli ze-LFP, ngelixa i-MegSolid inokuvavanya a Inketho yeseli yebhetri ye-solid-state eyenzelwe iprojekthi ngokukodwa. Abathengi kufuneka basebenzise i Isishwankathelo senkqubo yokugcina amandla yeMegSolid yokugcina i-solid-state kwaye kufuneke i-quotation, i-datasheet esayiniweyo kunye ne-BOM ukuchonga imodeli yeseli enikiweyo, ikhemistri yekathode, uyilo lwe-electrolyte kunye nomda ubungqina. Uyilo lwe-solid-state oluxhaswayo lunokunciphisa iingozi ezithile, kodwa akufunekanga luhlalutywe njengokuphelisa i-thermal runaway okanye ukuthatha indawo ye-BMS, i-PCS, ulawulo lobushushu, izilawuli zomlilo kunye nokuqaliswa kokusebenza.

Faka la maPharamitha angathumelwa kumazwe angaphandle kwi-EPC RFQ.

Thumela wonke umnikezeli-nkonzo ishedyuli yokulawula efanayo. Oku kuguqula “akukho thumelo ngaphandle lufunekayo” kube sisicwangciso esifanayo sezixhobo, isoftware kunye nokuqaliswa kokusebenza, kwaye kuchaza uxanduva olusileleyo phambi kokuba kube yeyalelo lotshintsho.

Sebenzisa i Isikhokelo sekhefu ledatha yocothelo lwexabiso le-BESS yaseMzantsi Afrika ukulungiselela isishwankathelo seprojekthi esibanzi, kunye ne Isakhelo seemfuno zofaneleko zabanikezeli be-BESS yorhwebo ukunikezela uxanduva lokudibanisa novavanyo. Ukuba lo msebenzi unokungena kwikhabhathi ye-100 kW / 215 kWh, qhubeka nge- ESSA0100B-0215 isikhokelo sokukhetha ngaphandle kokuthatha ngokuba amandla ayo avavanyiweyo alingana nokuhanjiswa kwe-AC okusebenzisekayo kweprojekthi.

Yintoni ekufuneka ithunyelwe kwi-MegSolid ukuze kwenziwe uphononongo lokungathunyelwa kwamanye amazwe

Uphando oluluncedo kufuneka luchaze umda wogunyathiso nolawulo, hayi nje i-kWh yebhetri. I-MegSolid ingakwazi ke ukubuyisa isakhiwo sokuqala, ichonge idatha engekho kwaye yohlukanise imisebenzi eqhelekileyo yezixhobo kubunjineli be-EMS obukhethekileyo beprojekthi.

Eli nqaku libonelela ngesakhelo semigangatho esisiseko sokungathumeli ngaphandle. Ukuze ufumane i-Excel PCC Control Narrative epheleleyo—equka imida yemitha enokulungiswa, uphango lwe-actuator, iimeko zokusilela konxibelelwano, iimeko zovavanyo lwe-FAT/SAT kunye neendawo zoxanduva lwe-RFQ—thumela i-imeyile. [email protected]. Bandakanya ilizwe leprojekthi, i-SLD, indawo ye-PCC, umthwalo kunye nedatha ye-PV, iimfuno zokuthumela ngaphandle, amandla kunye namandla e-BESS afunekayo, kunye neshedyuli yokuhambisa.

Imibuzo Ebuzwa Rhoqo

Kufuneka ichaze indawo yokujonga ye-PCC, umgaqo wophawu lwamandla, isilwanyana ekujoliswe kuso, ukuthambekela okanye umda wokunyamezela wokungenisa, umda wethutyana ovumelekileyo, i-asethi ezilawulwayo, umgangatho wokulinganisa, indlela yokusabela, imeko yokhuseleko lokusilela kunye nobungqina be-FAT/SAT.

Kufuneka balinganise amandla amanethi kwindawo yokudibanisa ye-PCC esemqathini kwaye bafake lonke umthwalo ofanelekileyo, i-inverter ye-PV kunye nomthombo wokondla we-BESS. I-SLD evunyiweyo kufuneka ibonise umlinganiselo we-CT, i-polarity, umzila we-phase kunye nobunini bemitha.

Iprojekthi kufuneka ivume iodolo ye-actuator. Ukutshaja kunokugcina ixabiso lamandla elanga xa isithuba sebhetri kunye nemida yewaranti ivumela; ukuncitshiswa kwe-PV kuyafuneka xa ibhetri ingakwazi ukufunxa amandla aneleyo okanye indlela yayo yokulawula ayifumaneki.

Akukho xabiso lufanayo kuyo yonke indawo. Useto luxhomekeke kwimfuno yokusebenza, ukuchaneka kwemitha, ukuguquguquka komthwalo wendawo, iindlela zokusebenza zesilawuli kunye nefuthe kwezorhwebo. Faka ixabiso nendlela ekuvunyelwene ngayo kwishedyuli yocwangciso-seto.

I-EMS kufuneka iqonde umda wokutshaja we-BMS okhoyo ize itshintshele kwesinye isisombululo esivunyiweyo, ngokuqhelekileyo inciphise ukuphuma kwamandla ebhetri ukuba isebenza, inciphise i-PV okanye ilawule omnye umthwalo osiqinisekisiweyo. Imfuneko ye-PCC ihlala isebenza.

Umlawuli kufuneka alahle idatha ephelelwe lixesha, enze isilumkiso ngokusilela, aze angene kwimeko ekhuselekileyo yokungathumeli ngaphandle evunyiweyo yeprojekthi. I-RFQ kufuneka ichaze amaxesha okuphelelwa kwexesha, indlela yokuziphatha kwendawo ye-PV/BESS, isaziso somsebenzisi kunye nokubuyiselwa okulawulwayo.

Ewe, kodwa ulawulo lokuthumela umbane kwigridi kunye nokusebenza njengesizinda esizimeleyo ziimeko zokusebenza ezahlukileyo. Imo yombhaki, ulwahlulo lokutshintsha, uxanduva lokwakha igridi kunye nolandelelwano lokubuyela kwi-grid kufuneka zithintele umjikelo wolawulo ongachanekanga ukuba uqhubeke usebenza.

I-FAT kufuneka iqinisekise icala lemitha, umthwalo kunye namanqanaba e-PV, imida ye-actuator, i-SOC ephezulu nephantsi, yonke ukusilela konxibelelwano, ukuqaliswa ngokutsha kwesilawuli, ukurekhodwa kwe-alam kunye nokubuyiselwa, kusetyenziswa ingxelo yolawulo evunyiweyo.

Bandakanya amandla e-PCC alungelelanisiweyo, umthwalo, amandla e-PV, amandla ebhetri, i-SOC, imida ye-BMS/PCS, usukelo lwe-EMS, iiyalelo ezikhutshiweyo, iimpendulo zokwenene, ii-alam, iiflegi zomgangatho wedatha kunye notshintsho kwimeko yokusebenza.

Iqonga le-ESSA lipapasha imisebenzi edityanisiweyo ye-EMS, unxibelelwano lwe-RS485/TCP-IP kunye nokufikelela kumthwalo, ibhetri, igridi, ijeneretha kunye ne-PV. Imitha yokwenene yokungathumeli mandla ngaphandle, ilojikhi, impendulo, imephu yobhaliso kunye nemida yokwamkelwa zihlala zixhomekeke kwiprojekthi nganye kwaye kufuneka ziqinisekiswe kumaxwebhu a-odolweyo.

Ulawulo lwe-BESS lokuthintela ukuthunyelwa ngaphandle kwamandla luphucumo oluvalekileyo olulinganisa amandla asebenzayo aqingqiweyo kwindawo yereferensi yegridi evunyiweyo, kwaye lulungelelanisa ibhetri, amandla elanga okanye ezinye i-asethi ezinokulawulwa ukuthintela ukuthunyelwa ngaphandle kwamandla ngenjongo.

I-PCC meter ithumela amandla ahlanzekileyo kwi-EMS. I-EMS iyawuthelekisa nesilindelo esivunyiweyo, isebenzise imida yebhetri nezixhobo, ize iyalele ukutshajwa kwe-BESS, ukuncitshiswa kokukhupha okanye ukunqunyulwa kwe-PV, ize iqinisekise impendulo elinganisiweyo.

Thumela i-SLD, i-PCC kunye nendawo ye-CT, umthwalo wamaxesha othile kunye nedatha ye-PV, iinkcukacha ze-inverter, iimfuno zokuthumela umbane ngaphandle, i-BESS efunekayo nge-kW ne-kWh, ivoltheji yegridi, i-interface zolawulo, iimfuno ze-FAT/SAT kunye neshedyuli yeprojekthi.

IMegSolid (Hong Kong) Limited igxile kuphando nophuhliso, uyilo kunye nokubonelela ngeenkqubo zokugcina amandla ezikumgangatho ophezulu. Ngalo mava obuchwepheshe esinawo emva kweminyaka elishumi, sinikezela nge-ESS yekhabhathi yangaphandle eyenziwe ngokweemfuno zomthengi, ii-inverters zasekhaya kunye nezisombululo zamandla eziphathwayo kubathengi behlabathi jikelele.
WhatsApp/Wechat: +852 59811073

Fumana isisombululo sakho seMegSolid sokugcina amandla kwiiyure ezingama-24.

Ngqo kumvelisi weebhetri ze-solid-state. Fumana isiphakamiso se-ESS esenziwe ngokweemfuno zakho, uhlalutyo lwe-ROI, kunye nesindululo senkqubo kwiqela lethu lobunjineli.

Into Oza Kuyifumana

Ityelelwe ehlabathini lonke:

UL, IEC, UN38.3, China Classification Society, GB36276-2023, RoHS

Iimodeli ezishushu:

Izicelo:

Iifektri · Iifama zelanga · Ezemigodi · IiZiqithi · Iziko leDatha

Sixelele ngeprojekthi yakho — siza kukuyilela inkqubo.