Energy Storage Inverters & Bidirectional PCS (3–500kW)

MegSolid manufactures three inverter and PCS families: R-series hybrid inverters — G2S-C 3–6kW residential and R30KH3–R50KH3 30–50kW three-phase 4-MPPT commercial hybrids; PMA modular rack PCS — 80–125kW, up to 98.7% efficiency; and MEGA TS isolated PCS — transformer-integrated MEGA0150TS for turnkey C&I BESS deployment.

Why Choose SolidESS Energy Storage Inverters & PCS

Discuss Your Inverter & PCS Requirements

Share your grid voltage, single/three-phase setup, required power (kW), and battery voltage so our engineers can match the right hybrid inverter or PCS for you.

تصفّح منتجات تخزين الطاقة لدينا

استعرض أنظمة البطاريات ومعدات تحويل القدرة المتاحة. افتح صفحة المنتج لمواصفات الطراز وتفاصيل التكوين والاستفسارات الفنية.

توفر عواكس MegSolid R30KH3–R50KH3 قدرة 30–50kW ودخل PV حتى 75kW وأربعة MPPT وتبديلًا احتياطيًا خلال أقل من 10ms.

الحماية من دخول الأجسام الصلبة والسوائل

IP65

الوزن (كجم)

٧٣ كجم

عداد

RS485

عاكس تخزين الطاقة
يوفر PCS MegSolid المعياري كفاءة تصل إلى 98.7% وتحويلًا ثنائي الاتجاه وتبديلًا أقل من 20ms وتكامل BMS وEMS.

الجهد المقنن (فولت)

400

الكفاءة القصوى

98.7%

دقة الجهد الكهربائي

±1%

تتميز سلسلة أنظمة التحكم في الطاقة (PCS) لتخزين الطاقة «MegSolid» بقدرة تتراوح بين 30 و500 كيلوواط بمحول عزل مدمج، ونطاق واسع لجهد البطارية، وكفاءة قصوى تصل إلى 97.5%. كما أنها تدعم التشغيل داخل الشبكة وخارجها، وتعديل الطاقة النشطة والردفية، والتشغيل البارد خارج الشبكة، والتوصيل المتوازي لما يصل إلى أربع وحدات.

الجهد المقنن (فولت)

400

نطاق الجهد (فولت)

320~460

THDi

<3%

G2S-C: محول تخزين الطاقة أحادي الطور
يُعد هذا العاكس أحادي الطور لتخزين الطاقة من طراز G2S-C جزءًا من سلسلة عواكس REVO المخصصة لتخزين الطاقة في المنازل. وهو يدعم التوصيل بالتيار المتردد سواء داخل الشبكة أو خارجها، والتوصيل ثلاثي الأطوار، والتشغيل المتوازي لعدة وحدات، كما أنه مزود بوظائف ذكية لإدارة الأحمال وترقية نظام إدارة البطارية (BMS) عن بُعد.

الحماية من دخول الأجسام الصلبة والسوائل

IP65

العرض

شاشة LCD

THDi

<3%

آلة متكاملة محمولة لتخزين الطاقة بين الحالة الصلبة والسائلة باستخدام محول التيار المتردد
محطة MegSolid المحمولة 500W/1kWh توفر سعة 1004.8Wh وموجة جيبية نقية وشحنًا شمسيًا MPPT بقدرة 300W و8000 دورة.

السعة

1 كيلوواط/ساعة

الدورات

8000

الضمان

5 سنوات

توفر عواكس MegSolid R30KH3–R50KH3 قدرة 30–50kW ودخل PV حتى 75kW وأربعة MPPT وتبديلًا احتياطيًا خلال أقل من 10ms.

الحماية من دخول الأجسام الصلبة والسوائل

IP65

الوزن (كجم)

٧٣ كجم

عداد

RS485

G2S-C: محول تخزين الطاقة أحادي الطور
يُعد هذا العاكس أحادي الطور لتخزين الطاقة من طراز G2S-C جزءًا من سلسلة عواكس REVO المخصصة لتخزين الطاقة في المنازل. وهو يدعم التوصيل بالتيار المتردد سواء داخل الشبكة أو خارجها، والتوصيل ثلاثي الأطوار، والتشغيل المتوازي لعدة وحدات، كما أنه مزود بوظائف ذكية لإدارة الأحمال وترقية نظام إدارة البطارية (BMS) عن بُعد.

الحماية من دخول الأجسام الصلبة والسوائل

IP65

العرض

شاشة LCD

THDi

<3%

عاكس تخزين الطاقة
يوفر PCS MegSolid المعياري كفاءة تصل إلى 98.7% وتحويلًا ثنائي الاتجاه وتبديلًا أقل من 20ms وتكامل BMS وEMS.

الجهد المقنن (فولت)

400

الكفاءة القصوى

98.7%

دقة الجهد الكهربائي

±1%

تتميز سلسلة أنظمة التحكم في الطاقة (PCS) لتخزين الطاقة «MegSolid» بقدرة تتراوح بين 30 و500 كيلوواط بمحول عزل مدمج، ونطاق واسع لجهد البطارية، وكفاءة قصوى تصل إلى 97.5%. كما أنها تدعم التشغيل داخل الشبكة وخارجها، وتعديل الطاقة النشطة والردفية، والتشغيل البارد خارج الشبكة، والتوصيل المتوازي لما يصل إلى أربع وحدات.

الجهد المقنن (فولت)

400

نطاق الجهد (فولت)

320~460

THDi

<3%

MegSolid Energy Storage Inverter & Bidirectional PCS Selection Matrix

As a specialized battery storage converter manufacturer, MegSolid engineers high-efficiency solid-state inverters and transformerless / isolated bidirectional power conversion systems (PCS) that maximize BESS round-trip efficiency (RTE) and grid stability.

Series / Model القدرة المقدرة للتيار المتردد DC Battery Voltage Window Topology & Key Specs التطبيق الأساسي
G2S-C Series (R3KL1DA–R6KL1DA-G2S-C) 3kW – 6kW (Single-Phase) 40V – 58V DC (48V / 51.2V) IP65 / < 20 ms Transfer / ≥150% Surge Residential & Light C&I Hybrid Storage
R30KH3 – R50KH3 Series 30kW – 50kW (Three-Phase) 150V – 800V DC (Dual 80A Ports) 4 MPPT (150–850V PV) / < 10 ms Transfer Commercial Solar-Plus-Storage & Multi-Roof Backup
PMA080 / PMA0105 / PMA0125 80kW – 125kW (Modular Rack PCS) 615V – 950V DC (3W+PE) 98.7% Max Efficiency / 100% Unbalanced 400V C&I BESS Cabinets & Unbalanced Microgrid Loads
MEGA0150TS / MEGA PCS Series 150kW (165kVA Floor-Standing) 420V – 850V DC (MEGA0150TS) Built-In Low-Frequency Isolation Transformer / IP21 Heavy Industrial Motors, CHP & Container BESS

INVERTER & PCS QUESTIONS

Choose the Right Inverter or PCS

1. What is the difference between a hybrid inverter and a bidirectional PCS?

Hybrid inverters typically combine solar PV inputs and battery control in one unit, while a bidirectional energy storage PCS controls power flow between the battery and AC system, with solar conversion equipment specified separately where required.

Published rated AC outputs are 3–6 kW for REVO G2S-C, 30–50 kW for R30KH3–R50KH3, 80/105/125 kW for نظام تحويل القدرة (PCS) المعياري من PMA and 30–500 kW for MEGA PCS, with selection based on your load, battery voltage and required operating mode.

Choose a single-phase hybrid inverter or a three-phase model according to your supply voltage, load distribution and backup-circuit design, checking phase-imbalance and parallel-operation limits for the exact configuration.

Confirm the battery's operating voltage, current limits, BMS protocol and firmware pairing using our دليل توافق البطارية والعاكس, since matching CAN or RS485 interfaces alone does not confirm that the equipment will work together.

Check PV voltage, MPPT operating range, string current and maximum array power against the selected three-phase hybrid inverter specifications, keeping maximum PV input separate from rated AC output and confirming the solar connection design for any PCS without built-in PV inputs.

Backup operation depends on the exact inverter or PCS model, battery and switching arrangement, so confirm critical-load power, starting demand, transfer time, grid isolation and protection requirements before specifying off-grid or emergency supply.

Request the model-specific datasheet, applicable grid-connection certificates, battery compatibility record and warranty terms, then agree the protection and commissioning checks described in our دليل الهندسة الخاص بنظام PCS.

Share your project country, application, AC voltage and phase arrangement, required output or load list, battery specifications and any solar or backup requirements to request an inverter or PCS quotation.

CAN 2.0B, RS485 and Modbus TCP are the communication protocols used across the MegSolid inverter and PCS range for closed-loop battery management system (BMS) integration. Confirm which protocols your exact inverter or PCS model and battery BMS support — including firmware, voltage window and pinout — in the model datasheet before ordering. For detailed pinouts and charge voltage matching, review our BMS-to-PCS voltage window and protocol matching guide.

A transformerless PCS system — such as the PMA080, PMA0105 and PMA0125 modular PCS — delivers up to 98.7% conversion efficiency for standard C&I peak shaving, whereas heavy inductive loads (pumps, compressors, and stamping presses) require high surge overload capacity. See our motor-starting PCS sizing and demand interval guide و PCC zero-export control specification guide.

من الاختيار إلى التسليم

Plan Your Inverter & PCS Configuration

01 / التحديد

Share Your Electrical Requirements

Project location, supply voltage, phase arrangement, connected loads and operating modes.

02 / الاختيار

Confirm Battery and Solar Inputs

Battery voltage, current limits, BMS protocol and PV string details where applicable.

03 / المراجعة

Review Compatibility and Approvals

Model and firmware pairing, grid requirements, protection settings and acceptance tests.

04 / التأكيد

Confirm Supply and Support

Product model, required accessories, delivery schedule, commissioning scope and warranty terms.

ست مزايا لأنظمة تخزين الطاقة بالبطاريات الصلبة من MegSolid

تقارير اختبار البطاريات ووثائق السلامة

راجع تقارير اختبار البطاريات وتقييمات النقل ووثائق السلامة. يمكن لفريقنا تأكيد الملفات المنطبقة على طرازك المختار وسوق الوجهة.

شهادة تقدير للإنجازات العلمية والتكنولوجية
تقييم التقنية · الغلاف

تقييم تقني 2024: «رائد دوليًا»

حاز اعترافًا في تقييم تقني عام 2024 نظّمته رابطة صناعة البطاريات الصينية.

① أربعة ابتكارات تقنية أساسية:تصلّب الإلكتروليت في الموقع وأغشية موصلة للأيونات وطلاءات كاثود فائقة الرقة وإعادة الليثة المسبقة بطبقة إلكتروليت صلبة واقية.

② أداء بطارية رائد:كثافة طاقة عالية ونتائج متقدمة في اختبارات الاختراق بالمسمار والتسخين ودورات الشحن.

③ براءات اختراع وأبحاث وتحقق:84 براءة اختراع ممنوحة · 86 منشورًا في SCI/EI · 9 معايير 13 تقرير اختبار من جهات خارجية · 2 من تقارير البحث عن الحداثة · 9 مراجع تطبيقية

تقرير اختبار UN 38.3

نتائج اختبار سلامة نقل البطارية للطراز الذي يغطيه التقرير.

تقرير تصنيف النقل

تصنيف النقل وشروط الشحن لطراز البطارية المحدد.

صحيفة بيانات سلامة المواد (MSDS)

معلومات السلامة لمناولة البطارية وتخزينها ونقلها والاستجابة للطوارئ.

مشاريع تخزين الطاقة وخبرة التطبيقات

استعرض أمثلة المشاريع بحسب التطبيق وتكوين النظام ونطاق التوريد. استخدم متطلبات مماثلة لبدء النقاش حول موقعك.

احصل على حل تخزين الطاقة MegSolid الخاص بك خلال 24 ساعة

مباشرةً من شركة مصنعة لبطاريات الحالة الصلبة. احصل على عرض مخصص لنظام تخزين الطاقة (ESS)، وتحليل العائد على الاستثمار، وتوصيات بشأن النظام من فريقنا الهندسي.

ما ستحصل عليه

موثوق بها في جميع أنحاء العالم:

UL، IEC، UN38.3، جمعية تصنيف السفن الصينية (CCS)، GB36276-2023، RoHS

الطرازات الأكثر رواجًا:

التطبيقات:

مصانع · مزارع شمسية · تعدين · جزر · مراكز بيانات

أخبرنا عن مشروعك لنقوم بتصميم النظام لك.