Energy Storage Inverters & Bidirectional PCS (3–500kW)
MegSolid manufactures three inverter and PCS families: R-series hybrid inverters — G2S-C 3–6kW residential and R30KH3–R50KH3 30–50kW three-phase 4-MPPT commercial hybrids; PMA modular rack PCS — 80–125kW, up to 98.7% efficiency; and MEGA TS isolated PCS — transformer-integrated MEGA0150TS for turnkey C&I BESS deployment.
Hybrid Solid-State Full Lineup
16–96kWh 51.2V Home Backup
215kWh–5MWh Cabinets & Containers
3–500kW Hybrid & Modular PCS
Why Choose SolidESS Energy Storage Inverters & PCS
- R-series hybrid inverters (G2S-C 3–6kW and R30KH3–R50KH3 30–50kW) and 30–500kW bidirectional PCS (PMA modular and MEGA TS isolated)
- Up to 98.7% max efficiency (PMA modular PCS) with transformerless and isolated PCS configurations
- Seamless on/off-grid backup switching, PCC zero-export control, and grid support
- Pre-configured CAN, RS485, and Modbus protocols for solid-state and LFP battery BMS
- Model-specific technical datasheets, grid-compliance certificates, and OEM/ODM support
Discuss Your Inverter & PCS Requirements
Share your grid voltage, single/three-phase setup, required power (kW), and battery voltage so our engineers can match the right hybrid inverter or PCS for you.
تصفّح منتجات تخزين الطاقة لدينا
استعرض أنظمة البطاريات ومعدات تحويل القدرة المتاحة. افتح صفحة المنتج لمواصفات الطراز وتفاصيل التكوين والاستفسارات الفنية.
الحماية من دخول الأجسام الصلبة والسوائل
IP65
الوزن (كجم)
٧٣ كجم
عداد
RS485
الجهد المقنن (فولت)
400
الكفاءة القصوى
98.7%
دقة الجهد الكهربائي
±1%
الجهد المقنن (فولت)
400
نطاق الجهد (فولت)
320~460
THDi
<3%
الحماية من دخول الأجسام الصلبة والسوائل
IP65
العرض
شاشة LCD
THDi
<3%
السعة
1 كيلوواط/ساعة
الدورات
8000
الضمان
5 سنوات
الحماية من دخول الأجسام الصلبة والسوائل
IP65
الوزن (كجم)
٧٣ كجم
عداد
RS485
الحماية من دخول الأجسام الصلبة والسوائل
IP65
العرض
شاشة LCD
THDi
<3%
الجهد المقنن (فولت)
400
الكفاءة القصوى
98.7%
دقة الجهد الكهربائي
±1%
الجهد المقنن (فولت)
400
نطاق الجهد (فولت)
320~460
THDi
<3%
MegSolid Energy Storage Inverter & Bidirectional PCS Selection Matrix
As a specialized battery storage converter manufacturer, MegSolid engineers high-efficiency solid-state inverters and transformerless / isolated bidirectional power conversion systems (PCS) that maximize BESS round-trip efficiency (RTE) and grid stability.
| Series / Model | القدرة المقدرة للتيار المتردد | DC Battery Voltage Window | Topology & Key Specs | التطبيق الأساسي |
|---|---|---|---|---|
| G2S-C Series (R3KL1DA–R6KL1DA-G2S-C) | 3kW – 6kW (Single-Phase) | 40V – 58V DC (48V / 51.2V) | IP65 / < 20 ms Transfer / ≥150% Surge | Residential & Light C&I Hybrid Storage |
| R30KH3 – R50KH3 Series | 30kW – 50kW (Three-Phase) | 150V – 800V DC (Dual 80A Ports) | 4 MPPT (150–850V PV) / < 10 ms Transfer | Commercial Solar-Plus-Storage & Multi-Roof Backup |
| PMA080 / PMA0105 / PMA0125 | 80kW – 125kW (Modular Rack PCS) | 615V – 950V DC (3W+PE) | 98.7% Max Efficiency / 100% Unbalanced 400V | C&I BESS Cabinets & Unbalanced Microgrid Loads |
| MEGA0150TS / MEGA PCS Series | 150kW (165kVA Floor-Standing) | 420V – 850V DC (MEGA0150TS) | Built-In Low-Frequency Isolation Transformer / IP21 | Heavy Industrial Motors, CHP & Container BESS |
INVERTER & PCS QUESTIONS
Choose the Right Inverter or PCS
1. What is the difference between a hybrid inverter and a bidirectional PCS?
Hybrid inverters typically combine solar PV inputs and battery control in one unit, while a bidirectional energy storage PCS controls power flow between the battery and AC system, with solar conversion equipment specified separately where required.
2. Which inverter and PCS power ratings does MegSolid offer?
Published rated AC outputs are 3–6 kW for REVO G2S-C, 30–50 kW for R30KH3–R50KH3, 80/105/125 kW for نظام تحويل القدرة (PCS) المعياري من PMA and 30–500 kW for MEGA PCS, with selection based on your load, battery voltage and required operating mode.
3. Should I choose a single-phase or three-phase hybrid inverter?
Choose a single-phase hybrid inverter or a three-phase model according to your supply voltage, load distribution and backup-circuit design, checking phase-imbalance and parallel-operation limits for the exact configuration.
4. Can these inverters and PCS work with my existing battery?
Confirm the battery's operating voltage, current limits, BMS protocol and firmware pairing using our دليل توافق البطارية والعاكس, since matching CAN or RS485 interfaces alone does not confirm that the equipment will work together.
5. What should I check before connecting solar panels?
Check PV voltage, MPPT operating range, string current and maximum array power against the selected three-phase hybrid inverter specifications, keeping maximum PV input separate from rated AC output and confirming the solar connection design for any PCS without built-in PV inputs.
6. Can the inverter or PCS supply backup power during a grid outage?
Backup operation depends on the exact inverter or PCS model, battery and switching arrangement, so confirm critical-load power, starting demand, transfer time, grid isolation and protection requirements before specifying off-grid or emergency supply.
7. Which datasheets and certifications should I request before ordering?
Request the model-specific datasheet, applicable grid-connection certificates, battery compatibility record and warranty terms, then agree the protection and commissioning checks described in our دليل الهندسة الخاص بنظام PCS.
8. How can I request an inverter or PCS quotation?
Share your project country, application, AC voltage and phase arrangement, required output or load list, battery specifications and any solar or backup requirements to request an inverter or PCS quotation.
9. How do I verify BMS-to-PCS communication protocol compatibility?
CAN 2.0B, RS485 and Modbus TCP are the communication protocols used across the MegSolid inverter and PCS range for closed-loop battery management system (BMS) integration. Confirm which protocols your exact inverter or PCS model and battery BMS support — including firmware, voltage window and pinout — in the model datasheet before ordering. For detailed pinouts and charge voltage matching, review our BMS-to-PCS voltage window and protocol matching guide.
10. Should I choose a transformerless PCS system or an isolated PCS for industrial motor starting?
A transformerless PCS system — such as the PMA080, PMA0105 and PMA0125 modular PCS — delivers up to 98.7% conversion efficiency for standard C&I peak shaving, whereas heavy inductive loads (pumps, compressors, and stamping presses) require high surge overload capacity. See our motor-starting PCS sizing and demand interval guide و PCC zero-export control specification guide.
من الاختيار إلى التسليم
Plan Your Inverter & PCS Configuration
01 / التحديد
Share Your Electrical Requirements
Project location, supply voltage, phase arrangement, connected loads and operating modes.
02 / الاختيار
Confirm Battery and Solar Inputs
Battery voltage, current limits, BMS protocol and PV string details where applicable.
03 / المراجعة
Review Compatibility and Approvals
Model and firmware pairing, grid requirements, protection settings and acceptance tests.
04 / التأكيد
Confirm Supply and Support
Product model, required accessories, delivery schedule, commissioning scope and warranty terms.
ست مزايا لأنظمة تخزين الطاقة بالبطاريات الصلبة من MegSolid
تقارير اختبار البطاريات ووثائق السلامة
راجع تقارير اختبار البطاريات وتقييمات النقل ووثائق السلامة. يمكن لفريقنا تأكيد الملفات المنطبقة على طرازك المختار وسوق الوجهة.
تقييم تقني 2024: «رائد دوليًا»
حاز اعترافًا في تقييم تقني عام 2024 نظّمته رابطة صناعة البطاريات الصينية.
① أربعة ابتكارات تقنية أساسية:تصلّب الإلكتروليت في الموقع وأغشية موصلة للأيونات وطلاءات كاثود فائقة الرقة وإعادة الليثة المسبقة بطبقة إلكتروليت صلبة واقية.
② أداء بطارية رائد:كثافة طاقة عالية ونتائج متقدمة في اختبارات الاختراق بالمسمار والتسخين ودورات الشحن.
③ براءات اختراع وأبحاث وتحقق:84 براءة اختراع ممنوحة · 86 منشورًا في SCI/EI · 9 معايير 13 تقرير اختبار من جهات خارجية · 2 من تقارير البحث عن الحداثة · 9 مراجع تطبيقية






مشاريع تخزين الطاقة وخبرة التطبيقات
استعرض أمثلة المشاريع بحسب التطبيق وتكوين النظام ونطاق التوريد. استخدم متطلبات مماثلة لبدء النقاش حول موقعك.
مشروع تخزين بطاريات لمصنع محامل
Renhe Machinery Bearings. الموقع: شاوشينغ. التكوين: 900 kW / 1,940 kWh. الهدف: نقل حمل الذروة والاحتياط الطارئ.
مشروع تخزين بطاريات لمصنع كهربائي
Yongyao Electric. الموقع: شوانتشنغ. التكوين: 200 kW / 450 kWh. الهدف: خفض تكاليف الكهرباء في الذروة ودعم استقرار طاقة الإنتاج.
مشروع تخزين بطاريات للطلاء الكهربائي
Northgate Electroplating. الموقع: نينغبو. التكوين: 200 kW / 430 kWh. الهدف: خفض تكاليف الكهرباء في الذروة وتثبيت الجهد عند بدء تشغيل المعدات.
مشروع تخزين بطاريات لمصنع طلاء كهربائي
Beilun Electroplating. الموقع: نينغبو. التكوين: 500 kW / 1,140 kWh. الهدف: إدارة أحمال الإنتاج المفاجئة وخفض تكاليف الكهرباء في الذروة وتقليل التوقف الناتج عن تذبذب الشبكة.
مشروع تخزين بطاريات على جانب المصنع
Newroute Intelligence. الموقع: نينغبو. التكوين: 200 kW / 430 kWh. تخزين طاقة على جانب المصنع بوحدات خزائن متوازية.
مشروع تخزين بطاريات على جانب الشبكة
Longquan Phase I. الموقع: لونغتشيوان، ليشوي، تشجيانغ. التكوين: 100 MW / 200 MWh. الهدف: ضبط التردد وخفض الذروة ودمج الطاقة المتجددة.