A Ukusilela kuvavanyo lomthamo lwe-BESS Ukuba akukho alamu isebenzayo akungqini ngokuzenzekelayo ukuba ibhetri inesiphene. I-MegSolid iqala ngokuhlanganisa ingcaciso yamandla asetyenzisiweyo, iimeko zokuqalisa nokumisa, uvavanyo lwamandla, imithwalo eyongezelelweyo, indawo yemitha kunye nezixhobo ezingafumanekiyo kunye nedatha efakwe kwi-BMS, PCS kunye nemitha yengeniso.
I-alamu iqinisekisa ukuba umda ocwangcisiweyo okanye umthetho wokhuseleko uwephiwe. Ayiqinisekisi ukuba inkqubo ilahle i-AC energy eqinisekisiweyo. Ngenxa yoko, i-HMI ekhangeleka iphilile ingakho ukubakho kunye novavanyo lokwamkelwa kwendawo olungaphumelelanga xa imida yovavanyo esivumelwaneni kunye neemeko zokusebenza zingahambelaniyo.
Kwesi sikhokelo, uza kufunda: indlela yokuchaza umda we-kWh ovavanyiweyo, ukuxilonga izizathu ezisixhenxe zokusilela okungakhange kubangele i-alam, ukugcina ubungqina obufunekayo kuvavanyo oluphindweyo olukhuselekileyo, kunye nokuguqula indlela yokwamkelwa ibe ngamaqela afanayo e-EPC RFQ.
Impendulo Ngqo: Ukungabikho Kwe-alam Akuthethi Ukuba Indawo Izele
Uvavanyo lunokuphoswa yinjongo yalo yamandla naxa onke amacandelo esahleli ngaphakathi kwemida yawo yokusebenza yasekuhlaleni. Umthamo sisiphumo esidibeneyo esijikeleza ixesha; ii-alam zihlala zichaza iimeko zangoko. Umahluko omncinci phakathi kwe-SOC-endpoint, imfuno eqhubekayo ye-HVAC okanye umda wokulinganisa okwicala elingelilo le-transformer unokudibana ube yintsilelo yezinto eziphathekayo ngaphandle kokubangela impazamo enye.
- 🎯 Iindawo zokuphelela ze-SOC: Uvavanyo aluqalanga kwimeko ephezulu evunyiweyo okanye luyeke kwimeko esezantsi ekuvunyelwene ngayo.
- ⚡ Umda wokulinganisa: Amandla e-nameplate e-DC athelekiswa namandla e-AC asemva kwesixhobo sokulungisa amandla (PCS), i-transformer okanye imitha ye-PCC.
- 🌡️ Iimeko zokusebenza: Iqondo lobushushu, inqanaba lamandla, imida yevoltheji okanye ukuncitshiswa kwamandla kwindawo zinciphise ixesha elifumanekayo.
- 🌀 Imfuno yocingo oluncedisayo: Izinto zokupholisa, iimpompo, izilawuli, iinkqubo zomlilo kunye neetransfoma zisebenzise amandla ngaphakathi kwemida yovavanyo.
- 🔌 Ukufumaneka kwezixhobo: I-string, i-rack, i-PCS block okanye i-auxiliary subsystem ibikho ngokwaneleyo ukuphepha uhambo kodwa ibingekafumaneki ngokupheleleyo kuvavanyo.
- ⏱️ Ukunyakaziswa kwedatha: Ukulungelelaniswa kwemitha, isivumelwano seempawu, isithuba sokuthatha iisampulu okanye ukulungelelaniswa kwexesha zonyuse isiphumo esidibeneyo.
- 🧪 Ukulungiselela uviwo: Ukulinganisa, ukuzinza kobushushu, ixesha lokuphumla okanye ukutshaja ngokupheleleyo azizange zifezekiswe phambi kokukhupha.
Ukuqinisekiswa kokusebenza kufuneka kuqinisekise kwaye kubhale phantsi ukuba inkqubo efakiweyo iyayifezekisa iinjongo ezichaziweyo, hayi nje ukuqinisekisa ukuba iyakwazi ukuvula. Olo mgaqo luyangqinelana ne Isikhokelo sokumiselwa seNcwadi yeDOE yokugcinwa kwamandla, eliphethe ukucwangcisa njengenkqubo yobungqina enamasango edityaniswe neemfuno zeprojekthi.
Chaza ukuba isivumelwano sivavanya yeyiphi ikhono.
Igama elithi umthamo alicacanga ngokwaneleyo ukuba lisetyenziswe kwisigwebo sokuphumelela/sokusilela. I-EPC kufuneka ichaze umda wombane, icala lamandla, isithuba sexesha, iindawo ezivunyelweyo ze-SOC okanye ze-voltage ekupheleni, unyango oluncedisayo kunye neemeko zokusingqongileyo. Kuvavanyo lokuhanjiswa kwe-AC, amandla alinganisiweyo yi-integral yexesha yamandla okwenene kwimitha ekhankanyiweyo; imitha kunye nesivumelwano sesalathiso kufuneka zichazwe phambi kovavanyo.
| Umda womthamo | Into eyimelayo | Kutheni ixabiso litshintsha |
|---|---|---|
| Amandla e-DC eselula okanye erakhini | Amandla ngaphakathi kwemida yebhetri | Akubandakanyi i-PCS, itransformer kunye nezinye iilahleko zokuncedisa. |
| Ii-terminals ze-PCS AC | Amandla aguqulwe yi-PCS | Iquka ibhetri kunye nokuziphatha kwe-PCS kodwa isenokungabandakanyi itransformer kunye nezixhobo zokuncedisa zasiza. |
| Imitha ye-transformer yohlobo lwe-BESS | Amandla emva kuguqulo kunye neziphumo zetransformer | Utshintsho ngelahleko ye-transformer kunye nendawo yokudibanisa encedisayo |
| Indawo yokudibanisa efanayo | Amandla aseleyo ahanjiswe kwisiza okanye kumda wegridi. | Isenokubandakanya umthwalo wesiza, i-PV, izixhobo zokuncedisa kunye nezinye izixhobo ngaphandle kokuba zahlulwe. |
| Amandla epleyiti yegama | Ixabiso lokugcina elipapashiweyo elisemthethweni okanye elilinganisiweyo | Akuthethi ukuba iya kusebenza ngokuzenzekelayo okanye ukuba i-AC iya kufakwa ngokuqinisekileyo. |
Phambi kokuba uthelekise izithembiso, sebenzisa i- Isikhokelo sokufumana indawo yokugcina amandla orhwebo Ukunyanzela wonke umnikezeli-tender ukuba abe kwimida efanayo yamandla, umbane noxanduva. Uthelekiso lwamaxabiso alusebenzi xa omnye umthengisi enika i-DC energy enesibizo kwaye omnye esamkela i-AC delivery enesiphumo kwi-PCC.
Izizathu Ezisixhenxe Zokusilela Komthamo we-BESS
Iindawo zokugqibela ze-SOC bezingalingani
I-SOC ebonisiweyo ye-100% luqikelelo olulawulwa yi-algorithm ye-BMS kunye nemida yokusebenza evunyiweyo; ayisosibonakaliso sokuba yonke i-string ifikelele kwimeko efanayo ye-electrochemical. Ngokufanayo, ukukhupha umbane kunokuma kuba enye i-string ifikelele kumda wayo wovoltage okanye wobushushu phambi kokuba isibonisi sendawo sifikelele kwi-SOC esezantsi esiqhelekileyo. Thelekisa iivoltage zepakethe neze-string, i-SOC, imeko yokugqitywa kokutshaja, imeko yokulungelelanisa kunye nomda wokuqala osebenzayo kwiziphelo zombini.
2. Imithwalo Yoncedo Yayibalwa Ngokwahlukileyo
I-Air conditioning, iimpompo zokupholisa ngokwengelosi, amandla okulawula, izifudumezi, imithwalo yenkqubo yomlilo kunye nokulahleka kwe-transformer xa ingenamthwalo zinokuba ngaphakathi okanye ngaphandle komda wemitha ekhethiweyo. Isiphumo somthamo kufuneka siveze ukuba kwamkelwa isiphumo esipheleleyo se-BESS okanye amandla anetiwekhi ahanjisiweyo. Rekhoda i-auxiliary kW kuyo yonke uvavanyo endaweni yokusebenzisa ipesenti engqinisekiswanga kamva.
3. Uvavanyo lwamandla lutshintshe amandla akhoyo
Uvavanyo lomthamo kwinqanaba elinye lamandla alunakuthathwa njengokumela wonke umsebenzi wokuthunyelwa. Umbane onamandla angaphezulu unokunyusa iilahleko zoguqulo nezokuchasa, ngelixa uvavanyo lwamandla aphantsi kakhulu lunokwandisa ixesha lokuchanabeka kwezixhobo ezincedisayo ezimileyo. Chaza iprofayili yamandla angaguqukiyo, ibhendi yokunyamezela, indlela yokuphatha ukunyuka kancinci, kunye nendlela ekuphathwa ngayo amaxesha angaphandle kwebhendi.
4. Ukulawulwa kweqondo lobushushu okanye kwezokufudumeza kuncitshisiwe iFastha
Inkqubo isenokunciphisa okanye iqinise imida yokutshaja nokukhupha umbane phambi kokuba ubushushu bube bukhulu ngokwaneleyo ukubangela ukuba ikhuphe isilumkiso. Bhala phantsi ubushushu obungqongileyo, ubushushu obumelweyo be-cell kunye nobushushu be-coolant okanye bekhabhathi, imeko yenkqubo yobushushu kunye nemida yamandla ye-BMS/PCS. Uvavanyo oluqalisiweyo phambi kokuba inkqubo ifikelele kwiimeko ezizinzileyo kunzima ukuluphinda okanye ukuluthethelela.
5. Intambo okanye iBhloko yamandla ibingafumaneki ngokuyinxenye
Intambo eqhawukileyo, imeko yekontaktha, ukukhutshwa kunxibelelwano okanye ukutsibela ngaphandle kolungiso lunokunciphisa amandla akhoyo ngaphandle kokucima lonke iziko. Irekhodi lokwamkelwa kufuneka lihambelanise ucwangciso olufakelweyo nolucwangciso olusebenzayo ekuqaleni, ngexesha lesiganeko esibekayo kunye nasekupheleni kokukhupha.
6. Ukulungelelanisa umgama okanye ixesha bekungachanekanga
Ukuphenduka kwesalathisi, impazamo yokulinganisa phakathi kwe-kW ne-W, umlinganiselo we-CT ongahambelaniyo, isikhewu sedatha okanye ukungahambelani kwe-clock zingenza ukuba ukukhupha umthwalo okusemthethweni kubonakale ngathi yimpazamo. Thelekisa imitha yengeniso kunye neetrendi ze-PCS ne-EMS kwisalathisi sexesha esifanayo. Isikhokelo somngqina sovavanyo lokwamkelwa kwemveliso yefektri ye-BESS Inceda ukuhambisa i-scaling, uphawu kunye nokujongwa kwe-data-chain phambi kovavanyo lwasesayithi.
7. Ulungiselelo lwangaphambili kunye nolandelelwano lovavanyo bezingaphelelanga
Inkqubo evunyiweyo kufuneka ichaze indlela yokutshaja, imigqaliselo yokugqiba, ithuba lokulungelelanisa, ixesha lokuphumla, ukuzinza kobushushu kunye nomsebenzi ongaphambili. Ukuba inkqubo ifika kuvavanyo emva kokuthunyelwa okungalawulwanga okanye ukutshaja okungaphelelanga, isiphumo asinakuthelekiswa ngqo nemeko esetyenziswe kwisivumelwano.
Sebenzisa Ubungqina Ukuwahlula Impazamo Yovavanyo Kwisithintelo Senkqubo
Musa ukuqala ngokutshintsha imida ye-SOC, ukuseta ngokutsha ii-alamu okanye ukutshintsha iimodyuli. Gcina iifayile zantlandlolo kwaye uchonge isiganeko sokuqala esatshintsha amandla, ukufumaneka okanye i-window yamandla. Idatha encinci efunekayo yile: amandla e-AC aceliweyo namlinganisweyo, imitha yesivumelwano, i-SOC ye-BESS, ivoltage kunye ne-current yebhetri, ukufumaneka kwe-string, imida yokutshaja/yokukhupha i-BMS, imida ye-PCS, amaqondo obushushu ameleyo, amandla oncedo kunye neelog zeziganeko ezihambelanisiweyo.
| Ipatheni eqatshiweyo | Ubungqina bokujonga kuqala | Isigqibo esinokwenzeka |
|---|---|---|
| Amandla azinzileyo, ukunqandwa kokukhutshelwa kwangoko | Umda wovoltage womtya wokuqala, isiphelo se-SOC, imitya engafumanekiyo | Qinisekisa ukuba iwindow kunye nestring zisebenziseka phambi kokuphinda uvavanye. |
| Amandla e-PCS ngokubanzi ayaphumelela; amandla e-PCC ayasilela. | Ukulahleka kwe-transformer, i-auxiliary meter kunye nomthwalo we-site ngaxeshanye | Ukucombulula umda wokulinganisa kunye nesibhambathiso sokuhanjiswa okucacileyo |
| Amandla ayancipha kancinci kancinci. | Ukusasazeka kweqondo lobushushu lweeseli, imeko yokupholisa okanye yokuhamba komoya, imida ye-BMS/PCS | Lungisa imeko yobushushu kwaye uphinde phantsi kwemeko evunyiweyo. |
| Isixa-mali se-mitha asihambelani nendlela ye-EMS. | Umlinganiselo we-CT, uphawu, ummandla wexesha, izikhewu zokuthatha isampulu kunye nokulinganiswa kwemitha | Qinisekisa izixhobo zokulinganisa phambi kokuba ubhengeze ukusilela kwebhetri. |
| Iimvavanyo eziphindaphindiweyo ziyahluka emva kwezibophelelo ezahlukeneyo zangaphambili. | Ulungiselelo lwangaphambili, ixesha lokuphumla, ukugqitywa kokutshaja kunye nemeko yokulinganisa | Misa umgangatho kulandelelwano kwaye useke isiseko esinokuphindaphindwa. |
Idatha yovavanyo-lomsebenzi kufuneka ichonge amandla atshintshiselwana nawo negridi, amandla aceliweyo kunye ne-SOC; ukulinganisa okongezelelweyo kwe-AC/DC, ukusetyenziswa kwesincedisi kunye nedatha yobushushu kuphucula ukusombulula imbangela engundoqo. Ezi ndidi zobungqina zikwabonakaliswa kwi Isikhokelo sovavanyo-sokusebenza se-NRECA BESS.
Bhala uVavanyo lweMpahla kwi-RFQ Phambi kokuNikezelwa kweSivumelwano
Iqela lezothengo linamandla angakumbi phambi kwesicelo sokuthenga kunasemva kwe-SAT ekuphikisanwe ngayo. Qhoboshela ishedyuli yovavanyo lwamandla kwi-RFQ kwaye ufune ukuba umnikezeli-tender ngamnye aphawule izinto ezibandakanyiweyo, ukuphambuka kunye neengqikelelo. Uluhlu lokujonga lokufunyanwa kwe-C&I BESS Ingasetyenziselwa uphononongo olubanzi lwezorhwebo, ngelixa ishedyuli yovavanyo inalo eli thungelwano lothotho lokwamkelwa.
- 📍 Indawo yokulinganisa: Igama lomitha, indawo ye-SLD, udidi lobuchaneko, umlinganiselo we-CT/PT, ukulinganisa kunye nesimiso seempawu.
- 🔋 Isiseko samandla: I-DC esemgangathweni, i-DC esetyenziswayo, amandla e-AC apheleleyo okanye amandla e-AC aselweyo ahanjisiweyo; imeko yokuqala yokuphila komatshini okanye enye imeko echazwe.
- ⬆️ Imeko yokuqala: Ukugqitywa kokutshaja, i-SOC ephezulu okanye iimfuno zovoltage, ukulungelelanisa, ukuzinza kunye nexesha lokuphumla elivumelekileyo.
- ⬇️ Imeko yokumisa: Imigangatho ye-SOC okanye yevoltheji ephantsi, isiganeko sokuqala sokuthintela, umda wokhuseleko kunye nendlela yokuphatha ukuphazanyiswa ngesandla.
- Izixhobo Iprofayile yamandla: I-kW elawulwayo, umda wokunyamezela, iirampu, izikhewu zokunqumama, imeko yamandla asabela kunye nezikhewu ezikhutshiweyo.
- 🌡️ Imeko-bume Uluhlu lobushushu bengqongileyo nebhetri, ukuphakama, imeko ye-HVAC kunye nemigaqo evunyiweyo yokunciphisa amandla.
- 🌀 Abancedisi: Imithwalo ebandakanyiweyo, imitha eyahlukileyo, ubalo lwe-gross/net kunye nendlela yokuphathwa kokuma.
- 📊 Iphakheji yedatha: Ifayile yomitha ekrwada, iitrendi ze-BMS/PCS/EMS, ilog yeziganeko, ireyithi yokuthatha isampulu, izitampu zexesha kunye netemplate yengxelo.
- ✅ Umgaqo wamkelo: Ijelo elijoliswe kulo, ukunyamezelwa, indlela yokulungisa, amalungelo okuvavanya kwakhona, iqela elinoxanduva kunye nesilungiso sesikhewu.
Faka i-Test Boundary kwiiModeli zeMegSolid C&I BESS
Amanqanaba emveliso yeMegSolid anika isiseko seqonga; awathathi ndawo yesiqinisekiso samandla asetyenziswayo esiphathelele kwiprojekthi ethile. Ikhotheshini e-odoliweyo, iphepha ledatha elisayiniweyo, i-BOM, i-SLD, inkcazelo yolawulo, iwaranti kunye nesicwangciso sokwamkelwa kufuneka zivumelane ngokuchanekileyo ngolungelelwaniso kunye neemeko zovavanyo.
| Isalathiso seMegSolid | Idatha eqinisekisiweyo epapashiweyo | Intshukumo yovavanyo lomthamo lwe-RFQ |
|---|---|---|
| ESSA0100B-0215 ikhabhathi yangaphandle | Amandla e-AC aqikelelwe kwi-100 kW; Umthamo oqikelelweyo we-215.04 kWh; I-0.5C kwi-25°C; Uhlobo lweseli ye-LFP | Musa ukuthembisa i-215.04 kWh kwi-PCC; chaza i-window ye-SOC esetyenziswayo, izixhobo zokuncedisa, amandla ovavanyo kunye nemida yomlinganiselo we-AC. |
| 261.24 kWh inkqubo epholisiweyo ngamanzi | Amandla aqikelelweyo angama-261.24 kWh; amandla e-AC aqikelelweyo angama-125 kVA; i-hybrid solid-state LFP-314Ah; ukusebenza kakuhle okuphezulu kwe-system yi-90% | Musa ukuphinda ubize ukusebenza kakuhle kakhulu kwenkqubo njenge-RTE eqinisekisiweyo; cela ixabiso neemeko zokwamkelwa kweprojekthi. |
| ESSA0050B-0100 ikhabhathi yangaphandle | Amandla e-AC aqikelelwe kwi-50 kW; Umthamo oqikelelweyo we-100.352 kWh; 0.5C kwi-25°C; Uhlobo lweseli ye-LFP | Sebenzisa umlinganiselo ofanayo kunye nomda oncedisayo xa uthelekisa iklasi eqhelekileyo yezihlandlo ezibini neyona ifunekayo yokuhanjiswa kwindawo. |
Kwiqonga langaphandle, phonononga i Iinkcukacha zekhabhathi yeMegSolid ESSA kunye ne Isikhokelo sokukhetha i-BESS ye-100 kW / 215 kWh. Kwenye indlela epholisiweyo ngamanzi, i 261.24 kWh i-BESS efudunyezwa ngamanzi, isikhokelo se-RFQ Igcina iingqikelelo zokusebenza kakuhle kwenkqubo, amandla kunye nokwamkeleka zohlukene.
Apho iprojekthi ifuna isicwangciso esiqinisekisiweyo se-hybrid solid-state, iMegSolid ingaphonononga ubungqina obufunekayo be-cell ne-system. Ulwakhiwo lwe-hybrid solid-state lunokunciphisa ukuchanabeka kwizinto ezilulwelo ezinokutsha kwaye luphucule ukumelana nezinye iindlela zokunwenwa kweziphene zangaphakathi xa luxhaswe bubungqina bovavanyo lwalo lwakhiwo lulungelelanisiweyo. Oku akwenza i-BESS ingatshi okanye akususi imfuneko yemiqathango ye-BMS, ulawulo lobushushu, ukufunyanwa, ukucinywa kunye neenkqubo zikaxakeka. Phonononga i MegSolid iinkqubo zokugcina amandla ezingaguqukiyo kunye ne Ii-12 zokujonga ukuqinisekisa ukuphuma elawulweni kokushisa ngaphandle kokudlulisela izimangalo ze-solid-state kwiimodeli eziqhelekileyo ze-LFP.
Thumela ubungqina obufanelekileyo kuvavanyo oluphindweyo olukhuselekileyo.
Thumela kuMegSolid icandelo elisayinwe lomthamo, i-SLD, indawo yemitha, imodeli e-odoliweyo kunye ne-BOM, isicwangciso sokumisa, i-raw meter export, iitrendi ze-BMS/PCS/EMS, iilogi ze-alam kunye neziganeko, idatha yamandla oncedo, amaqondo obushushu angqongileyo nawebhetri, iimeko zokuqala nokumisa, i-kW eliyalelweyo, ukunqongophala okubonweyo kunye nembali yokuvavanywa kwangaphambili. Oku kuvumela uphononongo lobunjineli ukuba lwahlule ukungangqinelani kwesivumelwano, ingxaki yezixhobo zokulinganisa, imeko yendawo kunye nemida yezixhobo phambi kokuba kucetyiswe umsebenzi wokulungisa.
Eli nqaku libonelela ngesakhelo esisiseko sokuxilonga nokufumana. Ukuze ufumane i-BESS Capacity Test Acceptance Workbook enokulungiswa—equka ishedyuli yemida yokulinganisa, iinkalo zokudityaniswa kwamandla, uluhlu lokujonga idatha elungelelanisiweyo, irekhodi lokuphinda uvavanye kunye ne-matrix yoxanduva lwe-RFQ—thumela i-imeyile. [email protected]. Bandakanya ilizwe leprojekthi, amandla kunye namandla e-BESS, imodeli ekhethiweyo, indawo yomitha yesivumelwano kunye nomhla olindelekileyo wokuhanjiswa.
Imibuzo Ebuzwa Rhoqo
Isivumelwano sovavanyo lomthamo lwe-BESS kufuneka sichaze ntoni?
Chaza isiseko samandla, imitha kunye nendawo ye-SLD, iimeko zokuqala nezokumisa, iprofayili yamandla angaguqukiyo, uluhlu lobushushu, unyango oluncedisayo, iifayile zedatha, umda wokudlula, indlela yokulungisa, amalungelo okuvavanya kwakhona kunye nesisombululo sorhwebo.
Ingaba i-BESS ingasilela kuvavanyo lwayo lomthamo ngaphandle kwesilumkiso esisebenzayo?
Ewe. Iindawo zokuphelela ze-SOC, ukusetyenziswa okongezelelweyo kwe-net, indawo yemitha, ukuncitshiswa kwamandla, imicu engasebenziyo, ukulinganisa okanye ukulungiselela okungaphelelanga kunokunciphisa amandla alinganisiweyo ngaphandle kokugqitha umda wempazamo ocwangcisiweyo.
Ingaba umthamo kufuneka ulinganiswe kwicala le-DC okanye kwicala le-AC?
Sebenzisa umda obizwe kwikhontrakthi. Iwaranti yokuhanjiswa kwisiza idla ngokufuna imitha ye-AC echongiweyo, ngelixa uvavanyo lokuxilonga lunokusebenzisa nemilinganiselo yebhetri ye-DC kunye ne-PCS ukwahlula iilahleko nemida.
Ingaba amandla oncedo e-BESS kufuneka achithwe kumandla anikezelweyo?
Ngokomda opheleleyo okanye ococekileyo ovunyiweyo kuphela. Chaza ukuba yeyiphi imithwalo yezixhobo zokupholisa, zokulawula, zomlilo, zokufudumeza, yepompo kunye netransformer ekubalweni, kwaye uzilinganise ngeemitha ngexesha lovavanyo apho kunokwenzeka khona.
Ingaba i-SOC ebonisiweyo yanele ukungqina iindawo zokuphela kovavanyo lomthamo?
Hayi. Rekhoda i-SOC kunye ne-voltage yepakethe neyomtya, i-current, imeko yokugqiba ukutshaja, imeko yokuqala yokubeka umda, isimo sokulinganisa kunye nemida esebenzayo ye-BMS okanye ye-PCS kwiziphelo zombini.
Yeyiphi idatha ekufuneka igcinwe emva kovavanyo lomthamo olungaphumelelanga?
Gcina umphumo ongaguqulwanga wemitha yesivumelwano yokuthumela ngaphandle, amandla aceliweyo nalawelweyo, imida ye-BMS ne-PCS, i-SOC, ivoltage yebhetri kunye ne-current, ukufumaneka kwe-string, amaqondo obushushu, amandla oncedo, ii-alam, iziganeko kunye neesitampu zexesha ezihambelanayo.
I-EPC kufuneka iphinde nini uvavanyo lomthamo lwe-BESS?
Phinda uyenze emva kokuba isizathu sesiphumo esingasebenziyo okanye esingaphumelelanga sibhalwe phantsi, amanyathelo okulungisa egqityiwe, izixhobo zokulinganisa ziqinisekisiwe, kwaye iimfuno ezivunyiweyo zokulungiselela kwangaphambili nezokusingqongileyo zinokuphinda zenziwe.
Ingaba i-kWh engunyazi ilingana namandla e-AC anokusetyenziswa?
Hayi. Amandla ebhetri aqhelekileyo awazibandakanyi ngokuzenzekelayo i-window ye-SOC evunyiweyo, iziphumo zoguqulo ne-transformer, izixhobo zokuncedisa, isipaji, iimeko zokushisa, ukufumaneka okanye imfuneko yokuphelelwa lixesha.
Ingaba i-ESSA0100B-0215 iqinisekisa i-215.04 kWh kwi-PCC?
Hayi. Ixabiso elipapashiweyo le-215.04 kWh yimthamo oqikelelweyo. Nayiphi na impahla ye-PCC eqinisekisiweyo kufuneka ichazwe ngokwahlukileyo kunye nomda wemitha, i-SOC window, amandla ovavanyo, unyango oluncedisayo, iimeko kunye nokunyamezela.
Umthengi kufuneka athumele ntoni kuMegSolid ukuze kwenziwe uphononongo lokunqongophala komthamo?
Thumela isivakalisi sovavanyo esisayiniweyo, i-SLD, imodeli elandelweyo kunye ne-BOM, iinkcukacha zemitha, iitrendi zedatha ekrwada, idatha encedisayo, amaqondo obushushu, iirekhodi zokuqala nezokuyeka, amandla ayalelweyo, amandla aqwalaselweyo kunye nembali yokuphinda uvavanye.
Yintoni ukusilela kuvavanyo lomthamo lwe-BESS?
Ukusilela kuvavanyo lomthamo we-BESS kwenzeka xa amandla alinganisiweyo phantsi kwenkqubo nemida evunyiweyo engafikeleli kwinjongo yesivumelwano okanye umda wokunyamezela, nokuba inkqubo isaqhuba kwaye ayibonisi lwelo lwengxaki.
Kutheni isixa samandla e-BESS esinokusetyenziswa sinokuba ngaphantsi komthamo oshicilelweyo?
Amandla asebenzisekayo anokuba ngaphantsi ngenxa yokuba umthamo oshicilelweyo uncitshiswe lifestile ye-SOC evunyiweyo, iziphumo zoguqulo neetransformer, ukusetyenziswa kwezixhobo zokuncedisa, iimfuno zomthamo ogciniweyo, imida yobushushu, izixhobo ezingafumanekiyo kunye nemida yekhoyili ekhethiweyo.
IMegSolid iyaphanda njani ukunqongophala komthamo we-BESS?
I-MegSolid iyanyanisa ikhontrakthi kunye ne-SLD kunye nedatha ehambelanayo yemitha, i-BMS, i-PCS, i-EMS, ubushushu, iinkonzo ezincedisayo kunye nokufumaneka, ichonga isiganeko sokuqala esibangela umda, kwaye ichaza ubungqina obufunekayo ukuze kuthathwe amanyathelo okulungisa okanye kuvavanywe kwakhona ngokulawulwayo.