Khuphela iPDF yezichazi zobuchwepheshe

Ingaba ibhetri ye-100 kWh yanele ihotele eseNigeria?

Ingcamango yobungakanani bokugcinwa kwebhetri yehotele yeMegSolid 100 kWh yehotele yaseNigeria enezixhobo zokuvavanya ilanga (solar PV), umnatha wogesi kunye nejeneretha.

A Ibhetri ye-100 kWh yehotele eseNigeria isenokwanela kwimithwalo ekhethiweyo ebalulekileyo, kodwa ayinakuvunywa ngenani lamagumbi okanye umthamo webhetri kuphela. I-MegSolid kuqala yahlula iinkonzo eziyimfuneko zehotele kwizinto ezikhululekisayo nemithwalo enokulindelwa, emva koko ibala amandla e-PCS, amandla ahanjisiweyo, i-SOC yogcino kunye nokukwazi ukutshaja kwakhona.

Eli nqaku lisekelwe kwipateni yophando engachazanga magama apho ihotele yaseNigeria icele malunga ne-100 kWh yokugcina ukuze inciphise iindleko zokusebenza, kodwa ayizange inikeze iprofayile yayo yokusetyenziswa kombane, idatha yejenereyitha, imo yegridi okanye iimeko zofakelo. Ngumgaqo-nkqubo wokufumana iimpahla, hayi ufakelo olugqityiweyo lweMegSolid kwaye asiyotho lwamaxabiso.

Impendulo eto: I-100 kWh ayisiqinisekiso sexesha lokusebenza

Amandla ebhetri nexesha lokuxhasa zinxulumene, kodwa azinakutshintshiselana. Umthengi kufuneka acacise ukuba i-100 kWh ithetha amandla e-DC aqhelekileyo, amandla e-DC asetyenziswayo okanye amandla e-AC aqinisekisiweyo kumda wokusasazwa wehotele. Iisetingi zokugcinwa ngumthengisi, ilahleko yoguqulo, ukusetyenziswa kwezincedisi, ubushushu nokwaluphala konke kuyichaphazela into efikelela kwimithwalo.

Ingxelo yomthengiKutheni ingaphelelangaKufuneka ingcaciso
Sidinga i-100 kWh.Amandla awachazi amandla okwangoko.I-kW/kVA yomthwalo ophezulu nowongxamisekileyo
Ihotele inamagumbi angamashumi amathathu.Inani lamagumbi alityhili imfuno ye-AC, yokufudumeza amanzi, okanye yekhitshi.Ishedyuli yomthwalo kunye nepateni yokuzala kwinqanaba lefeeder
Sidinga i-backup ubusuku bonkeUbude bobusuku abufani nomthwalo oqhubekayo.Iprofayile yomthwalo obalulekileyo elandelelaniswe ngokwexesha
Ilanga liza kulitshaja kwakhonaIsiphumo se-PV siyatshintsha ngokwemozulu, ubungakanani besigcawu sophahla kunye nemfuno yehotele emini.Ingeniso ye-PV ngeyure kunye nesalala sokutshaja esiseleyo
Ijenereyitha sele ifakiweIreyithingi yayo ayichazi ukulibaziseka kokuqalisa, umthwalo omncinci, okanye umda wokutshaja.Umlawuli, isilinganiselo, imida yokusebenza kunye nendlela yokulungelelanisa

Inkqubo ephakhejiweyo ekhutshwayo yelungiselelwe inani elithile lamagumbi isenokungachaneki xa ihotele ine-air-conditioning esembindini, isifudumezi-manzi sombane, iilifti, indawo yokuhlamba iimpahla, amagumbi abandayo okanye iimpompo ezinkulu. Sebenzisa i- Isikhokelo sokukhetha i-BESS yangaphandle ye-100 kW / 215 kWh ukubona isizathu sokuba amandla kunye ne-energy kufuneka kuhlolwe ngokuzimeleyo.

Yakha iMephu yoPhambili lweMithwalo yeeHotele phambi kokulinganisa iBESS

Umnini wehotele kufuneka enze isigqibo sokuba iindwendwe nabasebenzi kufuneka bafumane ntoni ngexesha lokunqamka kombane. Ukugcina i-reception, ukhuseleko, izixhobo zenethiwekhi kunye nezixhobo zokupholisa zisebenza sisithembiso senkonzo esahlukileyo kunokusebenzisa zonke izixhobo zokupholisa umoya kumagumbi eendwendwe, izifudumezi zamanzi, iilifti kunye nezixhobo zasekhitshini.

Imephu yezibonelelo zokuthwela iihotele yokuvavanya ukuba i-BESS eyi-100 kWh yanele na eNigeria
Iqela lokulayishaIinkcukacha ze-RFQ zokuqokelelwaYintoni etshintsha uyilo
Ukupholisa umoyaIyunithi ye-kW, isixa, uhlobo lwe-compressor kunye neshedyuli yokusebenzaUmgaqo-nkqubo wemfuno efanayo, umbane wokuqalisa kunye nolawulo lwegumbi
Ukupompa amanziI-motor kW/kVA, isiqalisi okanye i-VFD, ishedyuli yokuhamba kunye nomthamo wetankiUmsebenzi wokuqala kunye nokuba ingaba ukutsalwa kwe-milk kunokutshintshelwa
UkubandisaIdatha yomcompressor, imida yobushushu kunye nolandelelwano lokuqalisa kwakhonaUlungelelwaniso oluqhubekayo lwamandla nokunyuka
IzinyusiUhlobo lokuqhuba, amandla avavanyelweyo, indlela yokuvuselela amandla kunye nemo yongxamisekoIincopho ezimfutshane, iihamoniki kunye nokufumaneka okulawulwayo
Ikhitshi nendawo yokuhlamba impahlaUluhlu lwezixhobo kunye neshedyuli yokusebenzaImithwalo emikhulu enenkcaso nokungqubana okunokuphetshwa

Imephu yokuqwalasela umthwalo ikwadalisa imfuneko yokuqala yolawulo lwe-EMS: yonke i-feeder ekhuselweyo idinga imeko enokulinganiswa, igunya lokutshintsha kunye nempendulo echaziweyo xa i-SOC yomthombo osisigxina iphantsi. Isikhokelo sesakhiwo sonxibelelwano se-BMS ne-EMS Ichaza isizathu sokuba imiyalelo, ingxelo kunye neemeko zokubuyela umva kufuneke zibe noqiniseko.

Ubungakanani bePCS Amandla Phambi Kokubala Ifestile Yokugcina

Amandla e-PCS aqhutywa yeyona mthwalo mkhulu uvunyiweyo osebenza ngaxeshanye, hayi yi-kWh yebhetri. Iiprojekthi zehotele kufuneka zikwajonge amandla asabela, ulungelelwaniso lwe-phase, ukuqaliswa kwe-compressor nepompo, imida ye-transformer kunye notshintsho phakathi kwegridi, i-BESS kunye nejeneretha.

Kumthwalo wehotele omncinci we-three-phase, thelekisa iireyithingi eziqinisekisiweyo nemida yobunxibelelwano bebhetri kwi Isikhokelo se-inverter ye-hybrid yamaphase amathathu eyi-30 kW, 40 kW ne-50 kW. Musa ukukhetha i-inverter ngenxa nje yokuba i-kW yayo iyangqamana nomthwalo oqikelelweyo.

Bala Amandla kwiFastha yeNkonzo

Yenza ishedyuli yomthwalo elandelelaniswe ngokwamaxesha yokunqunyanyiswa kombane okufunekayo. Kwinqanaba ngalinye lexesha, yongeza imithwalo evunyiweyo, phinda-phinda amandla ngexesha lokusebenza, uze usebenzise umda wokuhanjiswa kwe-AC ochaziweyo weprojekthi, i-SOC egciniweyo, umthwalo oncedisayo kunye neemfuno zokwaluphala. Cela ababizibidelo ukuba babonise ezo xabiso ngokwahlukeneyo kunokuba bazifihle ngaphakathi kwisibonelelo esinye esikhulu kakhulu.

Injongo yenkonzoIngeniso yamandlaIngeniso yamandlaUbungqina bokwamkelwa
Ibhulorho yokuqalisa ijenerethaIinyathelo zomthwalo obalulekileyo neziganeko zemotoIxesha elilinganisiweyo lokuqala nelokufanelekaUvavanyo oluzenzekelayo lotshintsho
Imithwalo ekhethiweyo yobusuku bonkeUmthwalo ophezulu ovunyelweyo okwenzeka ngaxeshanyeIshedyuli yemithwalo yeyureUkufakwa kwamandla e-AC kwimitha evunyelwene ngayo.
Ukusetyenziswa kwelanga ngokwakhoImida yokutshaja nokukhupha i-PCSInzuzo ye-PV yeyure nganye kunye nemfuno yangokuhlwaIprofayili yokuthunyelwa ngokweemitha
Ulawulo oluphezuluUmda ophezulu wokungenisaUbude nexesha lokuphindaphinda kweziganeko eziphezuluUhlobo lwempembelelo ye-PCC nokuchacha kwe-SOC

Ukulungelelanisa iGridi, iSolar, iBESS kunye neJenereyitha nge-EMS

Ihotele yaseNigeria isoloko idinga iindlela ezininzi zokusebenza kunokuba ibe yinkqubo enye engaguqukiyo. Ingxelo yolawulo kufuneka icacise ukubaluleka kwemithombo, igunya lokuqalisa nokumisa ijenereyitha, imida yokutshaja ye-BESS, i-SOC yomthamo ogciniweyo, ukucinywa kombane kunye nokubuyisela imeko esemgangathweni emva kokusilela konxibelelwano.

Imephu yezibonelelo zokuthwela iihotele yokuvavanya ukuba i-BESS eyi-100 kWh yanele na eNigeria

I- Isikhokelo se-microgrid yaseNigeria esine-PV, idizili, ne-BESS ibonelela ngolwakhiwo olubanzi oluxubeneyo. Eli phepha lehotele longeza izigqibo zokuzala, zenkonzo yeendwendwe kunye nezokuphathwa komthwalo, ezingasonjululwa yoyilo oluqhelekileyo lwe-microgrid.

Yeyiphi i-MegSolid System ekufuneka ihotele iyivavanye?

I-MegSolid akufanelanga iguqule isicelo se-100 kWh ibe lukhetho lwemveliso oluzenzekelayo. Ikhathalogu yangoku inika iikhandidethi ezininzi ezingqinisisiweyo ze-C&I, kodwa isifundo somthwalo wehotele kufuneka kuqala siqinisekise amandla, amandla aveliswayo, ukupholisa, ivoltheji, imeko yofakelo kunye nomda wesatifikethi.

Imodeli okanye usapho olungqiniweyoUluhlu olupapashiweyoAmagama okupholisa nekhemistriUmda wovavanyo
ESSA0050B-010050 kW / 100.352 kWhUkupholisa umoya okubalulekileyo; LFPUmgqatswa uya kuba ngumntu kuphela emva kokuba i-kW ephezulu, i-window yamandla asetyenziswayo kunye nomthwalo womatshini ziqinisekisiwe.
ESSA0100B-0215100 kW / 215.04 kWhUkupholisa umoya okubalulekileyo; LFPVavanya xa zombini amandla ombane we-AC kunye namandla afunekayo edlula imida yekhabhathi encinci.
Inkqubo yeMeg-Solid Energon C&I125 kVA / 261.24 kWhUkupholisa ngamanzi; 314 Ah LFPHlola ivoltheji, imeko yobushushu, umthwalo wamandla anikezelweyo kunye namaxwebhu awenzelwe imodeli ethile.

Iqonga le-ESSA lixhasa uqhagamshelwano olulodwa kwi-load, ibhetri, i-grid, ijenereyitha yedizili kunye ne-PV, kunye nemisebenzi ye-EMS edityanisiweyo. Itheyibhile yemodeli yalo yangoku ikwaludwelisa i-400 V AC, inkxaso ye-on-grid/off-grid, kunye nonxibelelwano lwe-RS485 ne-TCP-IP. Phonononga i- Iinkcukacha zekhabhathi yangaphandle yeMegSolid ESSA kwaye ucele idatasheet yangoku elawulwayo phambi kokuba uyilo lwamkelwe.

Kwiiprojekthi ezicinga ngokupholisa okukumandla aphezulu nokupholisa okungamanzi, sebenzisa i- 261 kWh i-liquid-cooled C&I isikhokelo se-RFQ. Ixabiso elipapashiweyo le-90% lale modeli yeyona nkqubo isebenza kakuhle, hayi ukusebenza kakuhle okuchaziweyo kuhambo olubuyayo.

Thatha i-Solid-State Configuration njengeNketho yeProjekthi, hayi njengesiBango esiqhelekileyo.

Itheyibhile yemodeli ye-ESSA esemgangathweni ichonga iiseli ze-LFP. I-MegSolid iqinisekisa ukuba iqonga le-ESSA lingalungiselelwa ukuba libe neeseli zebhetri ze-solid-state ukuhlangabezana neemfuno ezithile zeprojekthi, kodwa loo nkqubela akufuneki ibhalwe ngokutsha njengombango wokuba yonke ikhabhathi ye-ESSA yi-hybrid solid-state. I-quotation, idatasheet esayiniweyo kunye ne-BOM kufuneka zichonge uyilo lweeseli kunye ne-electrolyte ebonelelweyo.

Ulwakhiwo lwe-solid-state lunokuphucula iimpawu ezithile zomngcipheko wobushushu xa luxhaswe bubungqina obuchanekileyo bovavanyo, kodwa akukho bheyatri ifanele ichazwe njengeyongazokutsha okanye njengeyisusa ukuphuma kobushushu okungalawulekiyo. Thelekisa ubungqina beprojekthi kwi Uluhlu lokujonga lokuvunywa kwe-battery ye-solid-state ekubalekeni kobushushu kwaye uphonononge okubanzi MegSolid iinkqubo zokugcina amandla ezingaguqukiyo iphepha.

Yongeza iimfuno zokuhlolwa nokungeniswa zaseNigeria kwi-RFQ.

Ukukhethwa kwezixhobo akuthathi indawo yemvume yombane yasekuhlaleni. INEMSA ithi ufakelo lombane kunye neenkqubo zombane kwiindawo zokusebenza zaseNigeria zifanele ukuhlolwa ngobuchwepheshe, kuvavanywe kwaye ziqinisekiswe, kwaye abasebenzi bofakelo kufuneka babe nezatifikethi ezifanelekileyo. Qinisekisa indlela yeprojekthi yangoku kunye neengcali zaseNigeria ezinoxanduva kunye ne Umyalelo wokuhlolwa nokuqinisekiswa kwe-NEMSA.

Kwiimveliso ezingeniswayo ezilawulwayo, i-Standards Organisation of Nigeria ichaza i-SONCAP njenginkqubo yangaphandle neyangaphambi kokuthunyelwa yokuvavanya ukuthotyelwa kwemigaqo. Umngenisi kunye ne-EPC kufuneka baqinisekise ukuba ingaba icandelo ngalinye elibonelelweyo lilawulwa, zeziphi iimbhalo ezisebenzayo kwaye ngubani onoxanduva lokukhulula phantsi kwe Ingcaciso esemthethweni ye-SONCAP.

Phambi kokuba ukhethe umthengisi, sebenzisa i- Isikhokelo sokuvavanya ababoneleli bokusonga amandla ebhetri baseNigeria. Bandakanya uvavanyo olubonwe ngumngqina kusetyenziswa i- Uluhlu lokujonga lwevavanyo lokwamkelwa kwemveliso yefektri yeBESS kunokuba kwamkelwe isatifikethi sovavanyo lwefektri esiqhelekileyo.

Uluhlu lokujonga lwe-RFQ yeHotele i-BESS

Ucaphulo oluluncedo luqala ngedatha yendawo elinganisiweyo. Thumela olu lwazi lulandelayo ukuze iMegSolid ikwazi ukwahlula iimbopheleleko zebhetri, iPCS, iEMS, iPV, ijeneretha kunye ne-EPC endaweni yokubeka ixabiso kwiphakheji engachazwanga ye-100 kWh.

Eli nqaku libonelela ngesikhokelo esisisiseko sokulinganisa ubungakanani be-BESS yehotele. Ukuze ufumane i-Hotel Load Schedule enokulungiswa kunye noluhlu lokujonga lwe-EPC RFQ, thumela i-imeyile. [email protected]. Bandakanya indawo yehotele, iprofayili yemithwalo, idatha yejenereyitha ne-PV, i-backup window efunekayo, ivoltheji yegridi, imeko yofakelo kunye nomhla ekujoliswe kuwo wokuhanjiswa.

Imibuzo Ebuzwa Rhoqo

Isenokwanela kwimithwalo ekhethiweyo ebalulekileyo, kodwa umthamo webhetri uwodwa awunakungqina ukufaneleka. Qinisekisa i-kW/kVA ngaxeshanye, iprofayile yomthwalo elandelelanayo ngokwexesha, ixesha elifunekayo lenkxaso, i-SOC yomthamo ogciniweyo, umda woguqulo kunye nobuchule bokutshaja kwakhona.

Inani lamagumbi alithembekanga njengomlinganiselo wokulinganisa ubungakanani. Iihotele ezimbini ezinamanani amagumbi afanayo zinokuba nemithwalo eyahluke kakhulu yokupholisa umoya, amanzi ashushu, iilifti, ikhitshi, indawo yokuhlamba iimpahla, izikhenkcezisi kunye nokumpompa.

Sebenzisa zontathu apho kufanelekileyo. I-kW ichaza amandla asebenzayo, i-kVA ibamba umthwalo wamandla abonakalayo kunye ne-power factor, kwaye i-kWh ichaza amandla agciniweyo ngokuhamba kwexesha. I-RFQ kufuneka ichaze umda wokulinganisa kunye newaranti kwesinye nesinye.

Kuphela xa i-PCS, ibhetri, inkqubo yokuhambisa kunye neshedyuli yokusebenza zenzelwe loo msebenzi. Uninzi lwabathengi kufuneka kuqala bachaze ukuba ngawaphi amagumbi okanye iindawo zikawonke-wonke ezisele zikhona nokuba i-air-conditioning ilungiselelwa njani ngexesha lokunqamka kombane.

Chaza igunya lokuqalisa ijeneretha, ixesha lokufaneleka, umthwalo omncinci, ukulungelelanisa, imida yokutshaja, iimeko zokumisa kunye nokubuyela emva kokusilela. I-EMS kufuneka ithintele ibhetri nejeneretha ekusabeleni kwisiganeko esinye ngaphandle kwemida elungelelanisiweyo.

Ayisuka kumandla e-PV kuphela. Bala imveliso ye-PV ngeyure, imfuno yehotele emini, imida yokutshaja, utshintsho lwemozulu kunye ne-SOC efunekayo phambi kokuphazamiseka okulandelayo. Sebenzisa kuphela intsalela efumanekayo emva kwemithwalo ephilayo kunye nemiqathango yokusebenza.

Iinjineli zehotele nezeprojekthi kufuneka zivume uluhlu lwezinga. Iqela eliqhelekileyo liquka iinkqubo zomthetho okanye zokhuseleko lobomi, indawo yokwamkela iindwendwe nokhuseleko, unxibelelwano, izixhobo zokupholisa, iimpompo zamanzi, imithwalo ethile yokunethezeka kunye neenkonzo ezinokulindelwa.

Umlinganiselo opapashiweyo we-ESSA0050B-0100 yi-50 kW / 100.352 kWh kunye nokupholisa umoya okubalulekileyo kunye neeseli ze-LFP. Lo ngumgqatswa nje kuphela; qinisekisa amandla aphezulu ehotele, umthwalo wamandla asebenzisekayo, ukuqalisa kwemoto, ivoltage kunye neemeko zofakelo phambi kokukhetha.

Iqonga le-ESSA lingalungiselelwa ngeeseli zebhetri ze-solid-state ukuze kuhlangatyezwane neemfuno ezithile zeeprojekthi. Ikhowuteshini, idatasheet esayiniweyo kunye ne-BOM kufuneka zichaze ngqo iseli kunye nesakhiwo se-electrolyte esihanjisiweyo; musa ukuqikelela ukuba yonke ikhabhathi ye-ESSA yi-solid-state.

Bona iimvavanyo ezivunyiweyo zokusebenza zokhuseleko, ii-alamu, unxibelelwano lwe-BMS/PCS/EMS, ulawulo lokutshaja nokukhupha umbane, uqhagamshelwano lwejenereyitha kunye nogridi, ulandelelwano lokucima umbane, ukuchaneka kwemitha, iziqhoboshi zongxamiseko kunye nesicwangciso sokubuyela emva xa ulahlekelwe luyungelelwano.

INEMSA ithi inyanzelisa imigangatho yobuchwepheshe kwaye iqhuba uphicotho, uvavanyo kunye nokuqinisekisa ufakelo lwezixhobo zombane neenkqubo zamandla kwiindawo zokusebenza zaseNigeria. Qinisekisa inkqubo yeprojekthi yangoku kunye neengcali zaseNigeria ezifanelekileyo kunye ngegosa elifanelekileyo.

I-SON ichaza i-SONCAP njenginkqubo yokuvavanya ukuthotyelwa kwemigaqo kwiimveliso ezingeniswa elizweni ezilawulwayo. Umngenisi kunye ne-EPC kufuneka baqinisekise udidi kunye namaxwebhu afunekayo kwicandelo ngalinye phambi kokuthunyelwa, kunokuba bathathe ngokuba isatifikethi esinye siyayigubungela yonke inkqubo.

Thumela i-imeyile [email protected] unikezela ngeendawo zehotele, idatha yemithwalo yexesha elithile, uluhlu lomthwalo obalulekileyo, iinkcukacha zejenereyitha neze-PV, ixesha elifunekayo lokuxhaswa, iimeko zofakelo, ivoltheji yegridi kunye nomhla ekujoliswe kuwo wokuhanjiswa.

IMegSolid (Hong Kong) Limited igxile kuphando nophuhliso, uyilo kunye nokubonelela ngeenkqubo zokugcina amandla ezikumgangatho ophezulu. Ngalo mava obuchwepheshe esinawo emva kweminyaka elishumi, sinikezela nge-ESS yekhabhathi yangaphandle eyenziwe ngokweemfuno zomthengi, ii-inverters zasekhaya kunye nezisombululo zamandla eziphathwayo kubathengi behlabathi jikelele.
WhatsApp/Wechat: +852 59811073

Fumana isisombululo sakho seMegSolid sokugcina amandla kwiiyure ezingama-24.

Ngqo kumvelisi weebhetri ze-solid-state. Fumana isiphakamiso se-ESS esenziwe ngokweemfuno zakho, uhlalutyo lwe-ROI, kunye nesindululo senkqubo kwiqela lethu lobunjineli.

Into Oza Kuyifumana

Ityelelwe ehlabathini lonke:

UL, IEC, UN38.3, China Classification Society, GB36276-2023, RoHS

Iimodeli ezishushu:

Izicelo:

Iifektri · Iifama zelanga · Ezemigodi · IiZiqithi · Iziko leDatha