Khuphela iPDF yezichazi zobuchwepheshe

Indlela yokudibanisa i-C&I BESS kwi-switchboard ye-400V esele ikho

A Uqhagamshelo lwe-400V BESS Kufuneka kuqalwe nge-switchboard esele ikhona, hayi ngexabiso lekhabhathi yebhetri. Umthengi kufuneka angqine ukuba ibhodi iyakwazi ukuthwala umbane ohamba macala omabini, ukunqamla umbane weempazamo okhoyo, ukugcina ukukhetha kokhuseleko kunye nokuxhasa indlela yokusebenza efunekayo. Esi sikhokelo sinika abanini bezibonelelo, abacebisi kunye namaqela e-EPC indlela esebenzisekayo ukusuka kwidatha yendawo ukuya kwishediyathi yomgca omnye (i-SLD) ekulungeleyo isigqibo kunye ne-RFQ.

Injineli yombane ikhangela iswitshibhodi ye-400 V esele ikhona phambi kokuba iqhagamshele i-MegSolid C&I BESS.

Okufuneka Kungqinwe Phambi Kwenxibelelwano ye-400V BESS

I-PCS elinganiselwe kwi-400V isenokuba lukhetho olufanelekileyo kweso siza, kodwa ivoltheji yodwa ayingqini ngokuba iyahambelana. Qinisekisa imvamisa, i-phase kunye nolungelelwaniso lwe-neutral, uluhlu lwe-voltage oluvumelekileyo, indlela yokwahlula, inkqubo yokufaka umhlaba, imisebenzi yokhuseleko kunye nendlela yokusebenza. I-MegSolid ipapasha ii-interface ezininzi ze-400V, kodwa usapho ngalunye lusebenzela umda owahlukileyo wamandla, amandla-gcina kunye nokudityaniswa.

Iqonga leMegSolidUjongano lwe-AC olusemthethweni loluntuSebenzisa oku kuphela njengomboniso wokuqala.
Ikhabhathi yangaphandle ye-ESSA400V; 320–460 V; 3W + N + PE; 30–100 kW kunye ne-55.296–215.04 kWhI-transformer yokwahlula edityanisiweyo; ukupholisa ngomoya okubalulekileyo; ukhetho lwe-solid-state cell olulungiselelwe iprojekthi kufuneka luchazwe kwikowuteshini nakwi-BOM.
Meg-Solid Energon 261.24 kWh480 V / 400V ±15%; 125 kVA314 Ah LFP kunye nokupholisa okungamanzi; iphepha likawonke-wonke alichazi le modeli njenge-hybrid solid-state.
I-MEGA TS PCS400V; 320–460 V; 3W + N + PE; 30–500 kWImilinganiselo yeetransformer zokwahlula ezidibeneyo iyahluka ngokwemodeli; ibhetri, iswitshi-gear kunye nobubanzi besistim zihlala zixhomekeke kwiprojekthi.
PMA PCS eyimodyuli400V ±15%; 80, 105 okanye 125 kW; umphumo ongaxhunyaniswanga 230/400VI-PCS yomgangatho-moduli; ukudityaniswa kwe-transformer nenkqubo epheleleyo kuxhomekeke kwiprojekthi.
iBESS ye-ESSC efakwe kwikhonteyina400V; 320–460 V; 3W + N + PE; 500 okanye 1,000 kW1.0752 okanye 2.1504 MWh; i-LFP enenkqubo yokupholisa umoya ekrelekrele elawulwa ngobushushu
I-5000 yangaphakathi690 V; 2.7 MW kunye ne-5.0159 MWhMusa ukuqikelela unxibelelwano oluthe ngqo lwe-400V; kufuneka isixhobo sovoltheji esiyilweyo kunye noyilo lwendawo.

Sebenzisa i Isikhokelo sokukhetha i-BESS yangaphandle ye-100 kW / 215 kWh ukwahlula amandla kumandla, kunye ne Isikhokelo se-RFQ senkqubo epholisiweyo ngokuyi-liquid engama-261 kWh xa loo klasi yekhabhathi iyangqamana nomsebenzi. Kummiso wemida we-PCS eyimodyuli, thelekisa Isikhokelo sokuthenga i-inverter yokugcina amandla engama-105 kW. Akukho nanye kwezi maphepha ethatha indawo yophononongo lwe-switchboard.

Chaza indlela yokusebenza phambi kokuba utsale isixhobo sokufaka.

Umlinganiselo wamandla ofanayo we-BESS unokuvelisa iidizayini zeswitshibhodi ezahluke kakhulu. Isixhobo sokuhambisa umbane esihamba ecaleni esisetyenziselwa ukunciphisa umthwalo ophezulu siqhele ukuhlala sixhumene nogridi. Inkonzo yenkxaso-mthwalo isenokufuna ibhasi eyahlukileyo yomthwalo obalulekileyo, amalungiselelo otshintshelo kunye nengqiqo ecacileyo yokwahlula imithombo. Ukuzenzela kwesiza sonke kongeza ukucinywa komthwalo, ulungelelwaniso lweejenereyitha, ulawulo lwefrikhwensi nolovoltiji, kunye nokulandelelaniswa kokubuyiselwa.

Isiphumo esifunekayoInkcazelo yento enxulumeneyoUmbuzo ekufuneka i-RFQ iphendule wona
Ukunciphisa incopho okanye ukutshintsha iitarifhiIsondli esisebenza macala omabini kwibhasi ebukhali ye-400VLoluphi uxinzelelo lokutshaja nokukhupha olunokwamkelwa yitransformer, ibhodi kunye nemida yerhafu?
Akukho nto ithunyelwa ngaphandleI-PCC meter okanye ii-CTs kufuneka zivalise umjikelo wolawulo lwe-EMS.Yeyiphi idivayisi elinganisa amandla aselayo, yeyiphi esebenzayo, kwaye yeyiphi imeko yokhuseleko ekuhlulekeni?
Ukugcina okukhethiweyoImithwalo ebalulekileyo idinga ibhasi yokuxhasa ecacisiweyo kunye nemida yokutshintshela.Zeziphi iilodi ezihlala zinamandla, ixesha elingakanani, kwaye imithombo ithintelwa njani ekusebenzeni ngokunxuseneyo okungakhuselekanga?
I-microgrid eyaziqhelanisileyoImisebenzi yokwakha igridi nolawulo lomthwalo kufuneka yabelwe.Ngubani ongumnini we-black start, i-synchronization yejenereyitha, i-load shedding kunye ne-return-to-grid logic?

Ukuze ube ngumnini wesignali, sebenzisa iMegSolid's. Isakhiwo sonxibelelwano se-BMS ne-EMS.Ukuba amandla abuyayo athintelwe, isivumelwano kufuneka sichaze umlinganiselo we-PCC, ukubekwa phambili kwe-actuator, imeko yokhuseleko xa kukho isiphoso kunye novavanyo lokwamkelwa kusetyenziswa iMegSolid's. Ulawulo lwe-BESS lokungathumeli ngaphandle kwi-PCC isakhelo.

Bala uMbane weFeeder Phambi kokuBhukisha iNdlela eyongezelelweyo

Ukuze ufumane isibalo esilungeleleneyo sokuhlola sezigaba ezithathu, sebenzisa Amandla = Uxinzelelo liphahlazwe ngesiqulatho se-√3 esiphindwe ngevolyumIiliza × PF). Umzekelo wokudluliselwa kwama-100 kW ku-400V kunye ne-power factor enye umalunga ne-144A. Oku asikokukhetha i-breaker okanye intambo: i-injiniyere kufuneka isacinge ngamandla abonakalayo, umthwalo wamandla asabayo, imigaqo yokulayisha eqhubekayo, ubushushu bengqongileyo, iimeko zokhuselo, ukwahlulwa ngamaqela, ubude bentambo, ii-harmonics, ukumelana neempazamo kunye neemfuno zaloo ndawo.

Ukuba iprojekthi ijolise ekulibaziseni ukwandiswa kombane, thelekisa umthwalo olinganisiweyo kunye nomqobo we-transformer ne Indlela yokuhlola uhlaziyo lwe-transformer ye-BESS. Ibhetri ingakwazi ukulawula umphakamo oxhomekeke kwixesha; ayinakukwazi ukulungisa amanqanaba eempazamo angonelanga, iswitshi-gear esonakeleyo okanye itopoloji yokudibanisa engafanelekanga.

Ukuqinisekiswa kokwenzeka okunezinto ezintlanu kokudibanisa i-C&I BESS kwi-switchboard ye-400 V esele ikho

Qinisekisa ulungelelwaniso lomthwalo wetyala nokhuseleko

Ukongeza i-PCS ehamba macala omabini kuyitshintsha inethiwekhi ebonwa yiswitshibhodi. Uphononongo kufuneka luqinisekise umsinga womjikelo omfutshane oqikelelwayo kwindawo yokudibanisa ecetywayo, igalelo le-PCS nobude bexesha bayo, umthamo wokuvula nokunqanda webreyikha, ukumelana nexesha elifutshane kwe-busbar, imisebenzi yereleyi nokwahlula kwizixhobo ezingaphezulu nezingezantsi. Isiphumo kufuneka siquke zonke iimeko ezithembekileyo zokudityaniswa kwigridi, zokugcina amandla, kunye nezozilungiso.

ye-ABB Uyilo olusisiseko lwe-BESS yovoltiji ephantsi ibonisa ukuba izixhobo zokutshintsha zombane nokhuseleko kufuneka zilungelelaniswe nesakhiwo esikhethiweyo. ISebe lezaMandla lase-U.S. likwabonelela nge Uluhlu lokujonga lokufunwa kweempahla lwe-BESS Kwimibuzo yokuqala yeprojekthi. Sebenzisa imigangatho, imithetho yeenkonzo, kunye neemfuno zonyanzeliso lwe-injiniyere enelayisensi ezilawula indawo kanye.

Qinisekisa iTopoloji eNgathathi Nxaxheba, yokuGxumeka eMhlabeni kunye neyokuLungiselela iMeko eMbi

Ixabiso le-400V alichazi ukuba ingaba indawo isebenzisa inkqubo yokuhambisa iintambo ezintathu okanye ezine, apho i-neutral idalwa khona, okanye indlela i-protective earth ne-neutral ezidityaniswe ngayo. Ezi nkcukacha ziba yinto ebaluleke kakhulu xa inkqubo ikwazi ukunika amandla imithwalo ngelixa umthombo wamandla ushenxile. I-SLD evunyiweyo kufuneka ibonise ulungiselelo lokusongwa kwe-transformer, umqhubi we-neutral, iindawo zokubethelela emhlabeni, utshintsho lomthombo kunye nendlela ekuphathwa ngayo imithwalo ye-single-phase.

Beka ii-CTs neeMitha kwimida yokwenene yolawulo.

I-EMS ayinakukwazi ukulawula into eyibona ngemitha yayo. I-CT efakwe kuphela kwi-BESS feeder entsha ilinganisa amandla ebhetri, hayi ukungeniswa okanye ukuthunyelwa kwendawo. Ukuze kulawulwe ixesha eliphezulu okanye kube sekukhutshweni okungekho nto, imitha yereferensi kufuneka ibe kumda osemthethweni wokusebenzisana kwaye ibandakanye lonke umthwalo kunye nemithombo efanelekileyo yendawo. Uluhlu lwe-SLD ne-I/O kufuneka lusebenzise amagama ezixhobo afanayo kunye nesimemezelo sesalathisi esifanayo.

BESS AC protection EMS metering and critical-load connection boundary at a 400 V main board

Khetha iNdawo yoNxibelelwano ngobungqina, hayi ngokulula.

Indawo yokunxibelelana nomgqatswaXa kunokwenzekaYintoni enokuyala
Indlela yokuphuma eyongezelelweyo kwibhodi engundoqo ekhoyoIsixhobo sokufaka esincinci okanye esiphakathi esinendawo eqinisekisiweyo, umthamo webhasi kunye nokhuselekoIsithuba esingonelanga phakathi kwe-busbar nentloko, umgangatho wempazamo, indawo ye-breaker, ufikelelo lwekhebula okanye ukukhetha
Icandelo elitsha le-switchboard okanye ibhodi edityaniswe ngeebhasiIbhodi ekhoyo ingakwazi ukuxhasa ukwandiswa kodwa ayinayo indawo efanelekileyo yokufaka izinto ezincinci.Umgangatho we-coupler ongqiniswanga, ingqiqo yokwahlula-hlula okanye uxanduva lwenguqu
Ibhodi ye-BESS ye-400V enikezelweyo kufutshane netransformer.Kufuneka abaphathi abaninzi be-BESS okanye ukwahlulwa ngokucacileyo kwezixhobo ezintsha nezindala.Umda wetranformer, umthwalo wokungena, indawo, indlela yekhebula okanye ukubalwa kwe-PCC akusombululwanga.
Uqhagamshelo lwe-voltage eyahlukileyo okanye oluphakathiI-power level yenza umbane we-voltage ephantsi kunye nenani lwekhebula zingasebenzi.Kufuna itransformer entsha, ingcamango yokhuseleko, isifundo sokudibanisa kunye nomda weprojekthi owahlukileyo.

Isigqibo sokudibanisa sifanele sibe kwi-SLD, hayi kwisivakalisi se-imeyile esifana nesithi “qhagamshela kwi-MDB.” Phambi kokukhutshwa kwesixhobo, lungelelanisa umda wombane kunye ne- Isakhiwo sokuguqula amandla se-PCS kwaye ukuqinisekisa i-interface ze-PCS ne-bhetri usebenzisa i- Uphononongo lwendibaniso ye-PCS ne-BMS.

Thumela le phakheji yedatha phambi kokuba ucele ikowuteshini.

I-quote eluncedo idinga ubungqina obaneleyo bokwahlula unikezelo lweMegSolid kwizibophelelo ze-EPC, zesiza kunye neenkonzo eziluncedo. Phawula amaxabiso angaziwayo njenge “aza kuqinisekiswa” endaweni yokucela ababoneleli ukuba baqashele. Iphakheji yophando elincinci kufuneka ibe nezi zinto zilandelayo:

IMegSolid ibonelela ngezixhobo zokugcina amandla, ii-inverters kunye ne-PCS ngaphakathi kwemida yeprojekthi ekuvunyelwene ngayo. IMegSolid ayibeki iimodyuli zelanga, iiraki ze-PV okanye ulwakhiwo lwe-PV lwasekuhlaleni njengenxalenye yesi sipho; apho i-PV sele ikho okanye icwangcisiwe, umthengi kufuneka ayifumane kwindawo yakhe aze anikezele ngedatha yayo yokudibanisa. Ukuqinisekiswa komthengisi kungalandela ke Uluhlu lokujonga lwe-RFQ yomthengisi we-BESS yorhwebo, kunye novavanyo lokuthunyelwa oluhambelanayo Isikhokelo sovavanyo lokwamkelwa kwemveliso yefektri yeBESS.

Phatha uCwangciso lwe-Solid-State kunye noKhuseleko lweQondo lobushushu njengezigqibo ezahlukileyo.

Kubathengi abafuna ugcino-amandla olungamanzi oluqinileyo, iqonga langaphandle le-ESSA C&I lakwa-MegSolid linokulungiselelwa ngeeseli zebhetri eziqinileyo ukuze kuhlangatyezwane neemfuno ezithile zeprojekthi. Olo khetho kufuneka lubhalwe kwikowuteshini, kwiphepha ledatha elisayiniweyo nakwi-BOM; akufuneki luqikelelwe ngokwegama losapho. Ukhuseleko lobushushu ngumba wonke-inkqubo obandakanya iseli, i-BMS, i-PCS, ukupholisa, isingxobo, ukufumanisa, ukucinezela, imida yokusebenza kunye noyilo lwendawo.

Sebenzisa i Ukuqinisekiswa kokuvunywa kokuphuma kobushushu okugqithisileyo kwebhetri ye-solid-state ukuqinisekisa ubungqina ngaphandle kokuphinda intengiso engaxhaswanga ethi “akukho kukhula kobushushu obungenakunqandwa”.

Into efunekayo ukuze i-MegSolid iphonononge i-400V SLD yakho

Thumela ezona zihlaziyiweyo ze-as-built SLD, iishedyuli zeetransformer neeswitshibhodi, idatha yemthwalo, iindlela zokusebenza ezifunekayo, indawo ecetywayo yokudibanisa kunye nexesha lokuhanjiswa ku [email protected]. Emva koko i-MegSolid ingakhetha usapho lweemveliso ze-400V ezifanelekileyo, ichonge iindawo zokusebenzisana ezingasonjululwanga ize ibuyise imibuzo yobuchwepheshe efunekayo kwisiphakamiso esikhethekileyo seprojekthi. Utshintsho lokugqibela lwebhodi yokutshintsha, useto lokhuseleko kunye nemvume yegunya lolawulo ziya kuhlala zixhomekeke kwiimfuno ze-EPC echongiweyo, i-injiniyela yombane kunye namagunya.

Eli nqaku libonelela ngesiseko somgaqo-nkqubo wokudibanisa i-400V BESS. Ukuze ufumane uluhlu lokujonga oluhlaziyekayo lophononongo lwe-switchboard kunye neshiti yesicelo sedatha ye-SLD, thumela i-imeyile. [email protected] kunye nelizwe leprojekthi, isicelo, amandla kunye namandla e-BESS afunekayo, idatha ye-transformer, isilinganiso sebhodi kunye nendlela yokusebenza ejongelweyo.

Imibuzo Ebuzwa Rhoqo

Ayikho kwimilinganiselo yevoltheji kuphela. Injineli yeprojekthi kufuneka iqinisekise umthamo we-busbar nowe-feeder, umthwalo wephutha, amanqanaba e-breaker, ukukhetha kokhuseleko, itopoloji ye-neutral neyomhlaba, iimitha, indlela yokusebenza kunye neemfuno zemvume yasekuhlaleni phambi kokuqhagamshela.

Thumela i-as-built SLD, iprofayile yemithwalo yamabanga, isilinganiso kunye ne-impedance ye-transformer, iishedyuli ze-switchboard kunye nee-breaker, idatha yeempazamo ekhoyo, useto lokhuseleko, uluhlu lwemithwalo ebalulekileyo, iinkcukacha ze-CT kunye nemitha, iimfuno zeendlela zokusebenza, iimeko zendawo kunye nomda wokuhanjiswa.

Ukuze ufumane isibalo esilungeleleneyo sokukhusela, sebenzisa i-I = P ihlelwe ngemveliso ye-square root yesi-3, ivoltage ukusuka kumgca ukuya komnye kunye ne-power factor. Ukukhetha i-breaker nechebile kusafuna amandla abonakalayo, i-duty cycle, i-derating, ii-harmonics, indlela yechebile kunye nezifundo zeempazamo.

IBESS idla ngokufuna indlela ecacileyo yokwahlula kunye nokhuseleko olukhethekileyo kwindawo yokudibana kwayo. Injineli echongiweyo kufuneka ikhethe imisebenzi ye-breaker neye-relay isuka kuphononongo lwangoku, lwempazamo, lokukhetha, kunye nolwemo yokusebenza.

Kuphela emva kokuba i-compartment yayo, i-busbar, i-breaker, ukugqitywa kwekhebula, umthamo wobushushu, i-fault rating kunye nokulungelelaniswa kokhuseleko ziqinisekisiwe. Indawo ebonakalayo yodwa ayisosibonakaliso sokuba le ndlela ifanelekile kumsebenzi we-BESS ehamba macala omabini.

Akukho mpendulo isebenzayo kuyo yonke indawo. Isigqibo sixhomekeke kwi-interface ye-PCS, ukubethwa komhlaba kwendawo, ukungqinelana kwe-voltage, imfuneko yokwahlulwa nge-galvanic, isifundo seempazamo kunye nendlela yokusebenza. Ezinye iiplatfomu zeMegSolid zidwelisa iitransformer zokwahlula ezidityanisiweyo, ngelixa ukudityaniswa kwenkqubo ye-PMA kuxhomekeke kwiprojekthi nganye.

I-SLD kufuneka ichaze ibhasi yomthwalo obalulekileyo, amalungiselelo omthombo-ukwahlula okanye ukudlulisa, indlela yokuziphatha engathathi cala nokubethelela emhlabeni, ukucinywa komthwalo, intsebenziswano yejenereyitha, ulandelelwano lokubuyisela kunye novavanyo lokwamkelwa. Isixhobo sokunciphisa umthwalo ophezulu esihamba ngokuhambelanayo negridi asiboneleli ngenkonzo yokuxhasa ngokuzenzekelayo.

Nika indawo yesixhobo, umlinganiselo we-CT kunye necala, imephu yamanqanaba, ukuchaneka, uluhlu lomlinganiselo, umgaqo weempawu, iprotocol yonxibelelwano, ireyithi yohlaziyo, ukulungelelaniswa kwexesha, iiflegi zomgangatho wedatha kunye nendlela esabela ngayo kumlinganiselo omdala okanye ophosakeleyo.

Hayi. Umda ofanelekileyo weMegSolid ziixhobo zokugcina amandla, ii-inverters kunye ne-PCS ngaphakathi kwemida yeprojekthi ekuvunyelwene ngayo. Iimodyuli zelanga, iinkqubo zokufaka kunye nokwakhiwa kwe-PV kwasekhaya kufuneka zifunyanwe kwingingqi; nikezela ngedatha yodibaniso lwe-PV ukuba i-BESS EMS kufuneka ilungelelanise nenkqubo ye-PV esele ikho okanye ecetywayo.

Ewe, iqonga le-ESSA elingaphandle le-C&I linokulungiselelwa ngeeseli zebhetri ze-solid-state ukuze kuhlangatyezwane neemfuno ezithile zeprojekthi. I-quotation, idatasheet esayiniweyo kunye ne-BOM kufuneka zichaze iseli enikiweyo kunye nolungiselelo; olu khetho aluyi bungqina bokuba yonke iyunithi ye-ESSA yi-solid-state.

Kufuneka ikhuphe iinkcukacha ezilandelayo: indawo yeprojekthi, indlela yokusebenza, i-kW okanye i-kVA efunekayo, i-kWh efunekayo kunye nexesha elithathwayo, ivoltage yegridi kunye nefrikhwensi, idatha ye-transformer, amanqanaba e-switchboard kunye ne-fault, indawo yokuqhagamshela, umda we-CT, imithwalo ebalulekileyo, iimeko zendawo, umda wokuthotyelwa kwemigaqo, i-Incoterm kunye nomhla wokuhanjiswa.

Kuqala, lungelelanisa ivoltage, uze uqinisekise umthamo wangoku, umthwalo weempazamo, ukukhetha kokhuseleko, i-neutral nokufakelwa emhlabeni, iimitha, indlela yokusebenza kunye nemida yoxanduva lwe-SLD phambi kokuba u-odole i-BESS okanye wenze utshintsho kwiswitshibhodi.

Cela uphononongo lokwenzeka kwe-SLD kunye neswitshi-bhodi elikhethekileyo kwiprojekthi. Uxwebhu olulandelayo oluluncedo asibrochure iqhelekileyo; yigrafu yemida enophawu kunye noluhlu lwezithuba zedatha olunxulumene netransformer yomthengi, ibhodi engundoqo, iprofayili yomthwalo kunye nomsebenzi wokusebenza.

IMegSolid (Hong Kong) Limited igxile kuphando nophuhliso, uyilo kunye nokubonelela ngeenkqubo zokugcina amandla ezikumgangatho ophezulu. Ngalo mava obuchwepheshe esinawo emva kweminyaka elishumi, sinikezela nge-ESS yekhabhathi yangaphandle eyenziwe ngokweemfuno zomthengi, ii-inverters zasekhaya kunye nezisombululo zamandla eziphathwayo kubathengi behlabathi jikelele.
WhatsApp/Wechat: +852 59811073

Fumana isisombululo sakho seMegSolid sokugcina amandla kwiiyure ezingama-24.

Ngqo kumvelisi weebhetri ze-solid-state. Fumana isiphakamiso se-ESS esenziwe ngokweemfuno zakho, uhlalutyo lwe-ROI, kunye nesindululo senkqubo kwiqela lethu lobunjineli.

Into Oza Kuyifumana

Ityelelwe ehlabathini lonke:

UL, IEC, UN38.3, China Classification Society, GB36276-2023, RoHS

Iimodeli ezishushu:

Izicelo:

Iifektri · Iifama zelanga · Ezemigodi · IiZiqithi · Iziko leDatha

Sixelele ngeprojekthi yakho — siza kukuyilela inkqubo.