Khuphela iPDF yezichazi zobuchwepheshe

Yeka Ukuhlawula Izohlwayo Zokugcina: Indawo Yokugcina Iibhetri ze-C&I yooMatshini boMbumbelo wePlastiki

Ugcino lwebhetri yeMegSolid C&I lweematshini zokubumba iplastiki nge-injection, olunciphisa incopho yemfuno ye-PCC ukusuka kwi-680 kW ukuya kumda wekhontrakthi we-500 kW kunye neemfuno zokukhupha i-180 kW ze-BESS.

Iifektri zokubumba iplastiki ngokuqhuzwa zinokufikelela kumda wamandla ombane kudala phambi kokuba ziphelelwe yindawo yokuvelisa. Oomatshini abaninzi bokubumba, iimpompo ze-hydraulic, izifudumezi zebharali, izipholisi, oomatshini bokomisa, kunye neekompressor zinokusebenza ngaxeshanye ngexesha elinye lokuvelisa, nto leyo etyhala imfuno ye-PCC ngaphezulu kwamandla akwintshayelelo yesivumelwano, nokuba ukusetyenziswa kombane ngokomyinge kusengaphantsi kolawulo. Oku kunokubangela izohlwayo zokugqitha umthamo, iintlawulo eziphezulu zomthamo ophezulu ofunwayo, okanye uxinzelelo lokuphucula i-transformer kunye nentambo yombane ukuze kuhlangatyezwane nemithamo ephezulu emalunga nexesha elithile loshifthi.

Ugcino lwebhetri lweMegSolid C&I lunika amandla kweso sikhewu sexeshana esingemva kwemitha.

Bala umsantsa wemthamo kwi-PCC

Ukuba ifektri ifikelela kwi-680kW xa umda osemqathini we-500kW, iba Ingxaki yokugqitha umthamo we-180kW:

680kW − 500kW = 180kW imfuneko yokukhupha kwe-BESS

Lungelelanisa udidi lwemveliso yeMegSolid nesiqwenga esilinganisiweyo: ESSA0100B-0215 ukufikelela kweyona nciphiso iphezulu ye-100kW, I-Energon 261 yamandla akumgangatho ophezulu wekhabhinethi, Iipcs ezinkulu yemisebenzi eyi-150–500kW, kwaye iBESS ye-ESSC efakwe kwikhonteyina kwiipiki zomzi-mveliso wonke eziphakathi kwe-500kW ne-1MW.

Iifayini zomthamo ziqala ngemithwalo yokuvelisa ehambelanayo

Oomatshini bokubumba ngokutofa abasebenzisi mandla angaguqukiyo kumjikelo ngamnye wemveliso. Ukuhamba kwe-clamp, ukutofa, uxinzelelo lokubamba, ukubuyiselwa kweskrufu, ukufudumeza ibharile, iimpompo ze-hydraulic, iinkqubo ze-servo, izipholisi, oomomisi, kunye neekompressor zidala iincopho eziphindaphindwayo. Iindleko zokwenene zivela xa iincopho ezininzi kuzo zidibana kwaye zityhalela imfuno iyonke yefektri ngaphezulu komda we-PCC.

Linganisa iProfayile yamandla yomjikelo wokubumba ngokutofa.

Ubunzima bomatshini bodwa abonelanga ukulinganisa i-BESS. Iimatshini ze-hydraulic, ze-servo-hydraulic, kunye nezo zikagesi kuphela zinokuba neeprofayili zombane ezahlukeneyo, nokuba zinesona sixa samandla sokubamba esifanayo.

Ulandelelwano lobungakanani: umjikelo womatshini → umthwalo odityanisiweyo wesityalo → incopho ye-PCC → umsantsa wemthamo osayinwe isivumelwano → amandla e-BESS afunekayo.

Ukuba isikhululo sombane sinyuka ukusuka kwi-450kW ukuya kwi-610kW ngokuchasene nomda we-500kW, i-BESS kufuneka isuse malunga ne-110kW. Idatha enesisombululo esiphezulu inokubonisa ukuba zeziphi oomatshini okanye izixhobo zokuncedisa ezenze lo mgangatho uphezulu.

Yahlula i-Transients Zokuqalisa I-motor Kwiirhafu Zofuno Nolungiselelo

Iintlawulo zamandla zilandela i-kWh, ngelixa iintlawulo zomthamo zilandela elona nani liphezulu le-kW okanye i-kVA elilinganisiweyo kwisithuba sokuhlawulisa senkonzo. Iintlawulo zokugqitha umthamo zisebenza kuphela apho itarifu okanye isivumelwano sokudibanisa sihlawulisa umthamo ongaphezulu komda osivunyelweneyo.

Ukungena okukhawulezileyo kwe-motor akusoloko kuthetha isiganeko sesidingo semizuzu eli-15. Ingxaki yorhwebo lulwelo oluphezulu oluzinzileyo okanye oluphindaphindiweyo. Ukuba isikhululo samandla siyafikelela kwi-620kW ngokuchasene nomda we-500kW, i-BESS kufuneka ibonelele malunga ne-120kW.

MegSolid Ulawulo lokunciphisa iincopho ze-PCC Ijolisa kulo mahluko kanye endaweni yokukhupha amandla angaguqukiyo angacwangciswanga.

Sebenzisa i-C&I Battery Storage ukugcina i-PCC Import ingaphantsi komda osetyenzwe ngokwezivumelwano.

Isigqibo sendlela yemveliso yeMegSolid yeefektri zokubumba ngokufaka, kuthelekiswa i-ESSA0100B-0215, i-Energon 261, i-MEGA PCS kunye ne-ESSC BESS ekwiikhontheyina, ngokwe-peak reduction elinganisiweyo, i-kVA duty, ixesha lesiganeko kunye ne-recharge window.

I-BESS ihlala ngasemva kwemitha kwaye ibonelela ngenxalenye yomrhumo wasemafaktri engaphezulu komda okhethiweyo wokungenisa umbane kwinethiwekhi. Oko kudlula umda ke kuba yithagethi yamandla elawulwayo kwi-PCC.

Ulawulo lokuNciphisa iNtsholo kwi-PCC

Uchungechunge lolawulo: I-PCC meter → EMS → PCS → ukukhupha ibhetri → ukungenisa kwinethiwekhi engaphantsi.

Xa imfuno isondela kumda ophezulu, i-PCS iyonyusa ukukhupha; xa imfuno iyehla, imveliso iyancipha. Ukutshaja kwakhona kufuneka kuhlale kungaphakathi kwesithuba esifumanekayo segridi.

Amandla e-PCS angama-100kW akanakususa ukugqitha okuzinzileyo okungama-170kW. Amandla e-MegSolid MEGA PCS kufuneka ahambelane nokunqongophala kwangempela kwefektri, ngelixa Ingqiqo yezinto eziphambili kwi-EMS Ilungelelanisa i-peak shaving, ukutshaja, i-SOC, kunye neminye imida yokusebenza.

Sebenzisa i-BESS njengendawo yokugcina amandla okwethutyana phambi kokuphuculwa kwegridi.

Masithi umzi-mveliso okhoyo ufinyelela kwi-720kW, unomda osivumelweneyo we-800kW, kwaye umatshini omtsha wokubumba wongeza i-160kW ngexesha elibalulekileyo lemveliso.

720kW + 160kW = 880kW

Isikhewu somthamo esivelisayo: 880kW − 800kW = Amashumi asibhozo eekhilowathi.

Ukukhululwa kwe-BESS obonelela nge-80kW kunokugcina ukungeniswa kwe-PCC kufutshane ne-800kW ngexesha lomsitho kwaye kulibazise uphuculo kwicala lenkonzo yombane.

I-BESS inciphisa ukungeniswa kumraro wogesi. Iintambo zangaphakathi, iibhaskithi, izitshixi, kunye neetransfoma kufuneka zisekwele umthwalo wokwenene wasefektri.

Ubungakanani bePCS, Amandla (kVA) kunye noMbane weBhetri ovela eFektri, uMthwalo

Qala nge-AC Duty phambi kwe-Battery kWh

Qala ngeenputs ezine: i-kW efunekayo, i-kVA efunekayo, ixesha lokuphakama, kunye nefestile yokutshaja kwakhona. I-kWh ekwipleyiti yebhetri ilandela ezo xabiso.

yaseMegSolid Ipotifoliyo yokugcinwa kwamandla ye-C&I Iquka amanqanaba amandla ekhabhinethi, e-PCS, nakwizikhongozeli kwezi ndima zahlukeneyo.

Yahlula amandla okunciphisa incopho kumandla esiganeko

Amandla achaza ukuba i-BESS ingayisusa kangakanani incopho; amandla kwezamandla achaza ukuba ingakugcina ixesha elingakanani olo nciphiso.

Ukuncitshiswa kwesona sixa siphezulu nge-90kW kangangemizuzu engama-20 kufuna malunga ne-30kWh phambi komda; ukuncitshiswa okufanayo nge-90kW kangangeeyure ezimbini kufuna malunga ne-180kWh.

IkhabhathiAmandla/amandla ombane apapashiweyoIbhetri / ukupholisaInqaku lokukhetha
ESSA0100B-0215100kW / 215.04kWh280Ah LFP, 768V DC eqhelekileyo, 0.5C kwi-25°C, ukupholisa ngomoya, IP54Uklasi lwekhabhathi oluthe ngqo lwemisebenzi ukuya kutsho kwi-100kW xa amandla asetyenzisiweyo ephumelele uvavanyo lwe-event
I-Energon 261125kVA / 261.24kWh314Ah LFP, 832V DC eqhelekileyo, ukupholisa ngokwamanzi, IP54I-125kVA akufuneki iphathwe njenge-output engaguqukiyo ye-125kW.

Ubungakanani bePCS, i-kW ne-kVA kwimithwalo yeemoto

Iifektri zokubumba ngokuqhuzwa ziquka iimoto, iimpompo, izipholisi, kunye neekompressor, ngoko ke ubungakanani bePCS kufuneka buqwalasele zombini i-kW kunye ne-kVA.

Ii-MEGA PCS zikhusela 30–500kW, enejongi ye-400V AC, ulawulo lwamandla asebenzayo/asabela, i-transformer yokwahlula eyakhelwe ngaphakathi, kunye ne-THDi kwi-on-grid engaphantsi kwe-3%.

Ii-plant ezifuna i-180kW yokunciphisa okuphezulu okuqhubekayo zidlula kwi-PCS ye-100kW ziye kwinqanaba lamandla elikhulu eliyilweyo. I-kWh yebhetri ayinakuhlengahlengisa ukunqaba kwamandla e-PCS okanye i-kVA.

Lungelelanisa i-Thermal Management kunye ne-Safety Architecture neMveliso ekhethiweyo.

I-ESSA0100B-0215 isebenzisa ukupholisa ngomoya, i-Energon 261 isebenzisa ukupholisa ngoketshezi, kwaye iinkqubo ze-ESSC ezikwizikhongozeli zisebenzisa ukupholisa ngomoya okulawulwa ubushushu.

ESSC0500B-1075 ibonelela 500kW / 1.0752MWh, ngelixa i-ESSC1000B-2150 inikezela 1MW / 2.1504MWh.

Ukhuseleko lweprojekthi lunokujonga i-IEC 62619, i-UL 9540, i-UL 9540A, kunye ne-NFPA 855 apho kusebenzayo kwimarike ekujoliswe kuyo nakugunya elilawulayo.

Yakha isizathu esisekelwe kwimali ngokusebenzisa iTariff yokwenyani neendleko zokuphucula.

Imbono yezemali kufuneka iqale ngexabiso eliphezulu elihlawulwayo kunye nexabiso lokwenene.

Bala iZaphulelo zeNtlawulo yeMfuno ukusuka kwiPiki ekwiMitha

Ukuba isityalo sinciphisa incopho yokubiza engama-500kW nge-300kW kwinqanaba lemfuno elingu-$20/kW, isiphumo esisebenzayo sithi:

Inani eliyi-$72,000 ligubungela ukuncitshiswa kwentlawulo yomrhumo kuphela. Yongeza iintlawulo zokugqitha umthamo okanye umsebenzi wenethiwekhi othotywe emva kwesikhathi ngokwahlukileyo apho zisebenzayo khona, usebenzisa iitarifu zokwenyani kunye nexesha lokubhala ityala.

Sebenzisa izikhuthazi emva kokuba inkqubo yombane ilinganisiwe.

Iiprojekthi zase-U.S. ezifanelekileyo zinokubandakanya iKhredithi yoTyalo-mali kuMbane oCocekileyo phantsi kweCandelo 48E kunye nokwehla kwexabiso elikhawuleziswe kwimodeli yezemali.

Ulandelelwano lwezemali: ingxaki yomthamo → amandla e-PCS → amandla ebhetri → iindleko zofakelo → ukonga ekusebenzeni → izikhuthazi.

Lo myalelo uthintela imodeli yezemali ekukhokeleleni umzi-mveliso kwibhetri enkulu kakhulu.

Sebenzisa iiNkonzo eziSekondari Kuphela emva kokuba i-SOC ekhuselekileyo ithenwe.

Ukunciphisa incopho kuseyiyo owona msebenzi uphambili. I-backup kunye ne-solar kufuneka ziyincede, hayi ukusebenzisa amandla okanye i-SOC efunekayo ukulawula umda womthamo.

Umgangatho Wombane Nokhuselo KokuPhelelwa Kombane Okuncinci

Ukuphazamiseka okufutshane kunokuphazamisa ii-PLCs, iimpompo, ukupholisa, ukuphathwa kwezinto, kunye nolawulo lwenkqubo, kudale ixesha lokungasebenzi elide kakhulu kunokuphazamiseka ngokwako.

Ukwenza ibackup kufuna ukwahlulwa kwegrid ngabom, izixhobo zokutshintshela, ibhasi yemithwalo ekhuselweyo, ukusebenza kwePCS okufanelekileyo, i-kVA eyaneleyo, kunye ne-SOC egciniweyo.

Ukuvikela ulawulo, ukupholisa, kunye nemithwalo yokucima elawulwayo kunokuba luncedo ngakumbi kunokwenza i-backup kuyo yonke imatshini yokubumba. I-MegSolid's Isikhokelo sokunqamka kombane kwi-BESS edityaniswe nogridi Ichaza lo mda.

Intsebenziswano neRoofutop Solar

I-PV yophahla inokunciphisa ukungeniswa kombane kwinethiwekhi emini, ngelixa i-BESS igcina umbane ogqithisileyo ovelisweyo okanye igcine amandla ngexesha lokusetyenziswa okukhulu.

Ukutshaja ngelanga akufanelanga kuphoselele i-PCC ngaphezulu komda osivumelweneyo, kwaye ubungakanani be-BESS kufuneka busalandela ukunqongophala komthamo wokwenene. Ulawulo lwe-PCC lokungathumeli ngaphandle Iyakwazi ukulungelelanisa ukusebenza kwe-PV nebhetri apho ukuthumela kumandla angaphandle kunqandwe.

Lungelelanisa i-MegSolid Platform neSikhewu seMpahla esiLinganisiweyo.

Ubungqina bobunjineli bokucheba iincopho kwi-injection molding obubonisa ulandelelwano lokulinganisa, ulawulo lwe-PCC, ikhonkco lolawulo lokucheba iincopho, amandla xa ethelekiswa namandla esiganeko kunye nomzekelo we-buffer yomthamo wethutyana we-80 kW

Iifektri zokubumba iplastiki ngokuzenzekelayo akufuneki zihlale zihlawula izohlwayo zokugcina amandla okanye zibambe ukwandisa oomatshini ngenxa yokuba ixesha elifutshane lokuphumelisa imveliso liphezulu kunomda wothungelwano lombane.

Indlela yokulinganisa: linganisa i-PCC → chonga umda osetyenzisiweyo → balisa i-kW/kVA egqithisileyo → linganisa ixesha → qinisekisa ukutshajwa kwakhona → khetha inkqubo ye-MegSolid.

Umda Wemveliso NgokweNciphiso Elilinganisiweyo Lencopho

Qhagamshelana neMegSolid ngeDatha yoMthwalo weFektri

Thumela idatha yemthwalo wexesha, umthamo osayinwe isivumelwano, incopho ye-PCC, ifaktha yamandla, amanqanaba okusebenza oomatshini, ishedyuli yemveliso, izongezo ezicwangcisiweyo, kunye nomyili womgca omnye ukuchaza amandla e-PCS, amandla ebhetri, ukutshajwa kwakhona, kunye nendlela yemveliso.

Imibuzo Ebuzwa Rhoqo

Ewe. Ukusebenza kwe-BESS elawulwa yi-PCC kunokugcina ukungeniswa kwegridi kungaphantsi komda osivumelweneyo xa inkqubo ilungiselelwe ukugubungela umsantsa wokugqitha okumlinganiswe.

Ewe, xa ukuncitshiswa kwesitshangatshanga esifunekayo kuhlala kungaphakathi kwi-100kW kwaye amandla ebhetri asetyenziswayo anokuxhasa eso siganeko.

Sebenzisa i-ESSA0100B-0215 ukufumana ukuncitshiswa okufikelela kwi-100kW peak. Sebenzisa i-Energon 261 xa kufuneka amandla amaninzi akumgangatho wekhabhathi, i-125kVA AC output, kunye nokupholisa ngolwelo.

Ewe, xa ingxaki ingumphakamo we-PCC oxhathisayo endaweni yokunqongophala okuqhubekayo komthamo wombane.

Thumela idatha yemithwalo yexesha elithile, i-kW okanye i-kVA eqinisekisiweyo, eyona mfuno iphezulu ye-PCC, ifactor yamandla, amanqanaba oomatshini abaphambili, ishedyuli yokuvelisa, uphandlo olucetyiweyo, kunye nedayagram yombane yomgca omnye.

IMegSolid (Hong Kong) Limited igxile kuphando nophuhliso, uyilo kunye nokubonelela ngeenkqubo zokugcina amandla ezikumgangatho ophezulu. Ngalo mava obuchwepheshe esinawo emva kweminyaka elishumi, sinikezela nge-ESS yekhabhathi yangaphandle eyenziwe ngokweemfuno zomthengi, ii-inverters zasekhaya kunye nezisombululo zamandla eziphathwayo kubathengi behlabathi jikelele.
WhatsApp/Wechat: +852 59811073

Fumana isisombululo sakho seMegSolid sokugcina amandla kwiiyure ezingama-24.

Ngqo kumvelisi weebhetri ze-solid-state. Fumana isiphakamiso se-ESS esenziwe ngokweemfuno zakho, uhlalutyo lwe-ROI, kunye nesindululo senkqubo kwiqela lethu lobunjineli.

Into Oza Kuyifumana

Ityelelwe ehlabathini lonke:

UL, IEC, UN38.3, China Classification Society, GB36276-2023, RoHS

Iimodeli ezishushu:

Izicelo:

Iifektri · Iifama zelanga · Ezemigodi · IiZiqithi · Iziko leDatha

Sixelele ngeprojekthi yakho — siza kukuyilela inkqubo.

Seraphinite AcceleratorOptimized by Seraphinite Accelerator
Turns on site high speed to be attractive for people and search engines.