Uvavanyo lokuNcitshiswa koMthamo lwe-Riyadh BESS: Ngaba yi-ESSA yokuPholisa ngomoya okanye yi-Energon yokuPholisa ngokweliqi?

Kwiyadi yeemizi-mveliso eRiyadh, iyeyona lixa inzima xa ubushushu bongaphandle, ilanga elikwikhabhathi kunye nomthwalo wefektri, zonke zidibana ngaxeshanye. MegSolid Inika iindawo ezimbini zokuqala zekhabhathi: ESSA0100B-0215 kwi 100 kW / 215.04 kWh ngokupholisa komoya okukrelekrele, kunye I-Energon 261 kwi 125 kVA / 261.24 kWh ngokupholisa okungulwelo.

Ukuthenga kuxhomekeke kwqondo lobushushu onokululinganisa. ESSA ipapasha Ukusuka kumaqanda angama-0 ukuya kuma-45°C. I-Energon ipapasha −20–55°C, kunye Ukuncipha kwamandla ngaphezulu kwe-45°C. I-envelope ye-55°C ixela kwi-EPC ukuba umatshini unokuhlala uvuliwe. Kusafuneka ube namandla afumanekayo kwindawo nganye yokusebenza ekumgangatho ophezulu wobushushu.

Thumela uMegSolid i uyilo lwendawo olungqongileyo, Iqondo lobushushu lokungenisa kwezixhobo kwaye iiyure zomthwalo opheleleyo ezingapheliyo. Iphasi yokuqala inokufaka umsebenzi kwi-ESSA window, kwi-Energon window, okanye kuvavanyo lobushushu beprojekthi.

Ikhabhathi yesiphelo-mveliso esisemthethweni i-ESSA0100B-0215 kunye nekhabhathi ye-Energon 261 enikiweyo zithelekiswa kwiyadi yoshishino eRiyadh.

I-ESSA ne-Energon ziyavavanywa ngokuthelekisa nobushushu obulinganisiweyo bokungenisa, umsebenzi oqhubekayo, kunye nomda wokunciphisa amandla obhengeziweyo.

Isiphumo sokukhetha ngokuskena okukhawulezayo

Imeko yeprojekthiESSA0100B-0215 uphononongoUphononongo lwe-Energon 261Inyathelo lesithembiso
Iqondo lobushushu lwezixhobo alidluli i-40°C.Umgqatswa wokuqala oqinileyoSebenzisa xa ezinye iimfuno zitsala ngaloo ndlela.Qinisekisa ikhava yamandla alinganisiweyo kunye nexesha lokuhluza
I-Intake ifikelela kuma-40–45°C xa ikhupha umoya ixesha elide.Kuxhomekeke kuhambo lomoya, uthuli nobungqina bomsebenzi onzima.Umgqatswa oqinileyo wolawulo lobushushuBona umthwalo obhengeziweyo kufutshane nobushushu obuphezulu
Utyando olucetyiweyo ngaphezulu kwe-45°CNgaphandle kwesigaba se-ESSA esipapashiweyoNgaphakathi kwesilinganiselo esipapashiweyo, ngokunciphisa amandlaNcamathelisa umgca wokunciphisa amandla we-Energon kunye neshedyuli yamandla asebenzayo.
Luthuli oluninzi, izihluzo ziyacocwa ngokwenene.Ukupholisa ngomoya kunokusebenza emva kokuphononongwa kokuhla koxinzelelo.Umjikelo olulwelo uthembele kancinci kumoya wekhabhathi ekupholiseni iseli.Bhala ukuhlolwa, ukucocwa, nokutshintshwa kwisivumelwano.
Inkonzo yokupholisa yasekuhlaleni elulaIndlela yemihla ngemihla elulaKufuneka ipompo, i-coolant kunye nokulungiswa kokuvuza.Ixabiso lezixhobo, iinxalenye ezitshintshwayo, uqeqesho kunye nexesha lokusabela
Umthwalo unikezelwe kuphela kwi-kWI-100 kW AC isikrini esicocekileyoI-125 kVA idinga isiqinisekiso se-power-factor.Rekhoda i-kW, i-kVA, i-power factor kunye ne-reactive duty ngokwahlukeneyo.

Thatha itheyibhile njengomgangatho wokuqala wokuhluza. Ukhetho lokugqibela lulandela iprofayili yomthwalo esayiniweyo, amandla asebenzisekayo, ulwakhiwo, ilanga, ukuphakama, isifundo sokhuseleko kunye nenguqulelo yemveliso elawulwayo.

Kubathengi abakumgangatho ophezulu baseSaudi: Iphepha lokufumana i-C&I BESS yaseSaudi yobushushu obuphezulu. Eli phepha limxinwa: indlela i-EPC eguqula iqondo lobushushu lasehlotyeni libe yifowuni yokunciphisa amandla engqinisisiweyo.

Qala ngokuthelekisa imida yemveliso emibini epapashiweyo.

Into epapashiweyoESSA0100B-0215I-Energon 261Inkcazelo yokufunwa kweempahla
Ixabiso le-AC elilinganisiweyoI-100 kW125 kVAI-Energon active kW ilandela iikhowudi ezivunyiweyo zofaktha wamandla kunye neethamali.
Amandla alinganisiweyo215.04 kWh261.24 kWhZombini zi-energy yegama; i-energy ye-AC esetyenziswayo ihlala ingeyeprojekthi ethile.
Ikhemestri yeeseliLFP314 Ah LFPQinisekisa uhlaziyo lwe-BOM kunye nedatasheet ezisiweyo.
UkubandisaUkupholisa umoya okubukrelekreleUkupholisa okuthe tyiwaUyilo lwezakhiwo lutshintsha ulondolozo nobungqina
IsingxoboIpasi-5, i-4Ipasi-5, i-4I-IP ikhusela ukungena kwamanzi; ukuphuma kobushushu kufuna ubungqina bawo.
Iqondo lobushushu lokusebenzaUkusuka kumaqanda angama-0 ukuya kuma-45°C−20–55°CI-Energon ithi amandla ayancipha xa iqhuba ngaphezu kwe-45°C.
Into ephambili yenkonzo yasemva kwesidloIndlela yomoya, isihluzo, iifeniUmjikelo wokupholisa, impompo, impendulo yokuvuza, ukulahla ubushushuFaka umsebenzi ngamnye kwishedyuli ye-O&M.

Ukuphuculwa kwe-ESSA kunye noqhagamshelwano: ESSA0100B-0215 iphepha lokukhetha imveliso ye-100 kW / 215.04 kWh.

Idatha ye-Energon: 261.24 kWh / 125 kVA iphepha lemveliso epholisiweyo ngamanzi. Ukusebenza okuphezulu kwe-system okudwelisiweyo yi 90%. Gcina elo nani lingabandakanywa kuyo nayiphi na iwaranti yokubuyiselwa kweprojekthi.

Sebenzisa iqondo lobushushu lokungenisa elixhobeni njengomlinganiselo wolawulo.

Umoya wezikhululo zemozulu uchaza le mmandla. Ikhabhathi ibona umoya kwiindawo zayo zokungenisa umoya nakwiindawo zokukhulula ubushushu.

Ingeniso ingatshisa ngenxa yokuba:

Bhala amaqondo obushushu amathathu kwi-tender:

Igama eliphathelene nobushushuInkcazelo yesicelo sesithembisoUbungqina obufunekayo
Uyilo lwendawo olujikelezileyoI-dry-bulb yangaphandle isetyenziselwe uyilo.Isiseko semozulu esivunyiweyo nendawo yomzekelo
Iqondo lobushushu lokungenisa kwizixhoboUmoya kwindawo yokungenisa umoya echazwe ngumenziUmzobo wendawo yesensor kunye nentsingiselo ye-SAT
Iqondo lobushushu lolawulo lwangaphakathiIxabiso leseli, imodyuli, isipholisi okanye ikhabhathi elisetyenziswa yi-BMS/EMSUluhlu lwamanqaku, imida ye-alam, ilog yeziganeko

Iziko leSizwe leMeteorology laseSaudi Arabia liye laqaphela amaqondo obushushu asehlotyeni asehlabathini angaphezulu kwe-50°C, kuquka 51.3°C e-Al-Ahsa ngoJulayi 2024, ngokwe Isishwankathelo se-Arhente yeeNdaba yaseSaudi. Oko kumisela imeko yengingqi. Umsebenzi ngamnye waseRiyadh usafuna ixabiso layo luyilo, indawo yokulinganisa kunye neengqikelelo zokuchanabeka.

Into eyinyaniso echazwa luluhlu lokusebenza lwe-55°C

I-Energon ingahlala ngaphakathi kweyapapashweyo yayo. −20–55°C uluhlu. Loo mpapashe inye ithi Ukuncipha kwamandla ngaphezulu kwe-45°C. Inani elifaneleyo kwitenderi yigrafu egobileyo: i-kW okanye i-kVA ekhoyo xa kuthelekiswa nobushushu.

Cela la manqaku okusebenza:

Iinkcukacha ezipapashiweyo ezivela kwa-SolaX nakwa-CLOU zibonisa indlela ababoneleli abahlula ngayo imida yobushushu bokusebenza kumandla apheleleyo. I-SolaX ichaza iqonga elifanayo elipholiswa ngamanzi elisebenza kude kube kuma-55°C kwaye linciphisa amandla xa iqingqiwe ngaphezu kwama-45°C.. I-CLOU ithengisa iindlela zokugcina ezilungele iintlango, ezisebenza kumaqondo obushushu angama-55°C kwaye zikhusela luthuli.. Sebenzisa la manani njengezikhokelo zentengo, ngelixa ugcina isilinganiso ngasinye sinxulumene neemeko zayo zemveliso novavanyo.

Into eyenzelwa yikhabhathi epholisiweyo ngomoya kukufakwa kwefiltha.

Ukupholisa ngomoya kuhambisa ubushushu kwindlela yokuhamba komoya elawulwayo. Uthuli lwenza ukumelana kuloo ndlela.

Indlela yomoya enothuli idla ngokuvela ngolu landelelwano:

Imida ingeyemodeli ehambisiweyo kunye nohlaziyo lwesoftware. Qhoboshela nayiphi na ibango elithi “dust ready” kumoya oqhubekayo, kumaqondo obushushu, nakwimpendulo zolawulo ezilinganisiweyo.

Iinjineli zivavanya indlela yomoya enothuli zisebenzisa ubungqina bokucofa komoya, obushushu, kunye nobhalo lweziganeko.

Uvavanyo lokuhamba komoya olulinganiselweyo ludibanisa imeko yesihluzo, ukuhla koxinzelelo, ukuhamba komoya, ubushushu bangaphakathi kunye nendlela esabela ngayo isilawuli kwisizinda sexesha esinye.

Ubungqina bokupholisa ngomoya bonyakanyelwe

Ezika-ESSA Ipasi-5, i-4 Ireyithingi isenendima ekungeneni kwezinto ngaphakathi. Ingcaciso ye-IEC ngamanqanaba okhuseleko lwe-IP ibonisa i-IEC 60529 echaza ukhuseleko kwizinto eziqinileyo nakwizinto ezingamanzi. Amandla angapheliyo kuma-45°C, ubomi besihluzo kuthuli lwaseRiyadh kunye nexesha lenkonzo yendawo zidinga ubungqina bazo.

Ukupholisa ngamanzi kuyayitshintsha uluhlu lokugcinwa.

I-Energon ihambisa isipholisi kwindlela yokuhamba kobushushu yebhetri. Ukudluliselwa kobushushu kwicala leseli kulawulwa ngakumbi, kwaye ipakethe ayixhomekekanga kangako kumoya wekhabhathi enkulu.

Isixhobo sisakhupha ubushushu esityeni. Jonga i-heat exchanger, i-radiator okanye i-chiller kulungiso olucetywayo, kunye neefeni kunye nayo nayiphi na indawo eqokelela uthuli.

Ubungqina bokupholisa ngamanzi bucelwe

Qala ngeprofayile yomthwalo, uze ujonge iipleyiti zegama zebhetri.

Ukupholisa kuxhomekeke kumthwalo osisebenzisayo ngokwenene.

Qokelela eyona datha igqwesileyo yemithwalo yamandla onayo uze uphawule iiyure apho iqondo lobushushu lasehlotyeni kunye nemveliso ye-BESS zidibana khona. Indawo yokugcina impahla etshaya imizuzu engama-20 ngexesha lokutshona kwelanga yimeko yobushushu eyahlukileyo kunesityalo esigcina imveliso epheleleyo iiyure ezine emva kwemini.

Ingeniso yomthwaloIsizathu sokuba itshintshe isigqibo sokupholisa
Amandla ombane afunekayo kwi-kWImisela umthwalo wombane ovelisa ubushushu
Amandla abonakalayo kwi-kVAIbamba i-power-factor kunye ne-headroom ye-reactive-current
Ixesha lokuqhubeka komthwalo opheleleyoYahlula umthwalo wobushushu oqhubekayo kwisiganeko esifutshane senkxaso.
Hlawula umrhumo phambi kokuba ukhutshwe.Yongeza ubushushu phambi kwefestile ebalulekileyo
I-SOC eqalayoUtshintsho olufumanekayo kumandla kunye nendlela yombane weseli
Ubuncinane be-SOC ebugciniweyoIkhusela xa kukho ukunqamka kombane okanye isipaji sokuqalisa ijeneretha
Iqondo lobushushu eliphezulu lokungenisaIkhetha imida yobushushu yemveliso
Ixesha lokuvezwa lilanga ngqoYongeza ubushushu bekhabhathi nobephedi ngexesha lomsebenzi.
Imeko yothuliItshintsha ukuhamba komoya kunye nokusebenza kokukhupha ubushushu

Bhala umda wokunciphisa amandla kwisibhengezo sesithembiso.

Sebenzisa ishedyuli enamagama achazekileyo nobungqina.

Inkcukacha yesiceloImfuneko ecetyiswayoUbungqina bokwamkelwa
Uyilo lwendawoChaza ixabiso lomboniso kunye nomthomboIsiseko soyilo esivunyiweyo
Indawo yokulinganisa yokungenisaChaza indawo nokhuseloUmzobo wendawo yesensor
Ukuchanabeka kwelangaIlanga elipheleleyo, umthunzi okanye indawo evalekileyoUcwangciso neziqikelelo zokushisa
Umphumo olinganisiweyoYahlula i-kW, i-kVA kunye ne-power factorIphepha ledatha elawulwayo kunye nekhwafu
Isiphumo sobushushu obuphezuluAmandla afunekayo kunye nexesha elifunekayo kwithemperetha nganyeIshedyuli yokunciphisa amandla yomenzi
Imeko yothuliUkuhlolwa kokucoca i-filter kunye nemeko yenkonzoUxinzelelo, ukuhamba komoya okanye irekhodi yolondolozo
Ukusetyenziswa okongezelelweyoIifeni, iimpompo nezixhobo zokushisaUhlobo lwe-FAT/SAT olulinganisiweyo
Ukusilela kokupholisaUkulumkisa, ukuthintela kunye nolandelelwano lokuvalaIrekhodi lovavanyo lwezizathu neziphumo
UkuchachaIngqiqo yokuqalisa ngokutsha nokubuyisela amandlaIlogi yomsitho kunye nokuqhuba okubonwe ngamehlo
UxanduvaIifilitha, isipholisi, iinxalenye ezitshintshwayo, inkonzoUmzila woxanduva wesivumelwano

Chaza ukuba isiphumo esifunekayo silinganiswa na kwiiziphelo ze-PCS, kwisiphumo se-AC sekhabhathi okanye kwindawo yokudibanisa. Umda ngamnye unelahleko eyahlukileyo ye-auxiliary neye-transformer.

Yakha i-FAT yobushushu obuphezulu ejikeleze umsebenzi obhengeziweyo.

I-FAT idinga ukuqalisa okuzinzileyo kunye nexesha elimisiweyo. Ukuvuselelwa kwamandla kwekhabhathi okufutshane akumeli ukuphuma kwamandla kweentsuku ezininzi zasehlotyeni.

Ulandelelwano lwe-FAT oluncinci

Irekhodi lovavanyo lwe-BESS FAT ne-SAT lwamaqondo obushushu aphezulu kwindawo yomsebenzi yamaqondo obushushu angama-45 eCelsius

Irekhodi elibonelweyo libandakanya umveliso wombane, i-SOC, umahluko wamaqondo obushushu amaseli, izixhobo zokuncedisa, izilumkiso, ukuncitshiswa komthamo kunye nokuchacha.

Umgca wamkelo kufuneka ucaphule umda wokunyamezela obhengeziweyo ngumthengisi. Ukuba itenderi ifuna isiphumo esipheleleyo kwi-45°C, umgca osayiniweyo kunye nomsebenzi obungqinisiweyo kufuneka uquke loo meko. Ukuba uceba ukusebenza ngaphezu kwe-45°C, isiphumo se-Energon esamkelweyo silandela ishedyuli yokunciphisa amandla yeprojekthi.

Ukulinganisa i-BOM evavanyiweyo, ilojiki yokhuseleko kunye neengxelo: Uluhlu lokujonga lwe-BESS lokuthelekisa izibango nobungqina bezokhuseleko.

Yisa ubungqina obufanayo kwi-SAT.

Iinkcukacha zasefektri zibeka umgangatho osisiseko womveliso. I-SAT iqinisekisa indlela efakelweyo yokukhupha ubushushu, izikhewu, iisensa, izilawuli kunye nokufikeleleka kolungiso.

Irekhodi ngexesha lokuqhutywa kwesiza:

Idatha yentsingiselo kwisiseko sexesha esinye kuyo yonke i-BMS, i-PCS, i-EMS kunye nemitha yengeniso. Iiwotshi ezingahambelaniyo ziqala iingxabano kamva.

Xa i-ESSA ilingcono njengendawo yokuqalela

Jonga i-ESSA0100B-0215 xa isixhobo esibhengeziweyo singena sihlala ngaphakathi. Ukusuka kumaqanda angama-0 ukuya kuma-45°C, i-AC output efunekayo iyangena I-100 kW, kwaye indawo iyakwazi ukugcina indlela yokuhamba komoya icocekile.

Sebenzisa i-ESSA xa ubungqina beprojekthi buqinisekisa:

Ufumana icacile 100 kW / 215.04 kWh Ikhabhathi yangaphandle enenkqubo yokupholisa umoya ekrelekrele kunye ne-IP54. Umsebenzi oqhelekileyo uba lula apho iqela lasekuhlaleni sele lisebenzisa inkqubo yokungenisa umoya yoshishino.

Xa i-Energon ileyona ndawo ingcono yokuqalela

Jonga i-Energon 261 xa umyinge wokungenisa uyasondela okanye uyidlula. Amashumi amane anesihlanu eedigri celsius, xa umthwalo uhlala ixesha elide, okanye indlela yokupholisa ibhetri ifuna ukupholiswa ngelaphu.

Sebenzisa i-Energon xa ubungqina beprojekthi buqinisekisa:

I-Energon ibonelela 261.24 kWh, 125 kVA, iiseli ze-LFP eziyi-314 Ah, ukupholisa okukwi-liquid kunye ne-IP54. Gcina iyunithi ye-kVA kwitheyibhile yobuchwepheshe nganye de kuvunywe umthwalo wamandla asebenzayo kunye ne-power factor.

I-MegSolid ingathelekisa iindlela zokwakha iikhabhathi ezimbini xa umthwalo womsebenzi ofanayo ulinganisiwe. Khetha ukupholisa ngomoya xa iqondo lobushushu lokungenisa, inkonzo yothuli kunye nemveliso eqhubekayo zihlala ngaphakathi kwemida ye-ESSA. Khetha ukupholisa ngoketshe xa umthwalo-msebenzi ufuna uluhlu olubanzi lokusebenza lwe-Energon kwaye isiza sinokugcina inkqubo yaso yokupholisa. Uphononongo lobuchwepheshe kufuneka luhambelane nokukhethwa kwekhabhathi, idatha ye-EMS, ubungqina bokunciphisa umthwalo kunye nerekhodi yokwamkelwa.

Usapho olupheleleyo lwekhabhathi: Iphepha lemveliso yokugcina amandla i-MegSolid C&I.

Thumela ezi ngingqinelwano ukuze ufumane isindululo sekhabhathi.

Inkcazelo efunekayoIfomathi ekhethwayo
Indawo yeprojekthiIsixeko, ummandla woshishino kunye nekoordinethi
Uyilo lwendawoElona qondo lobushushu liphezulu le-dry-bulb kunye nomthombo
Ukwamkelwa kwezixhoboIxabiso elilinganisiweyo okanye imodeli yokuqala yobushushu
Ukuchanabeka kwelangaIlanga elipheleleyo, umthunzi okanye igumbi lezixhobo
Umthwalo womsebenziUthotho lwexesha lwe-kW ne-kVA
Ixesha lokuthwala umthwalo opheleleyoImizuzu okanye iiyure ngesiganeko ngasinye
Umlinganiselo wamandlaElona nani lincinci nelijolisweyo
Irhafu yamandlaI-AC kWh efunekayo enokusetyenziswa
Imeko yothuliInkcazelo yendawo kunye nexesha elicetywayo lenkonzo
Umthamo wokugcinaIsihluzo, isipholisi, impompo kunye nokukwazi ukusabela ekuvuzeni
Ujongano lwegridiI-voltage, i-frequency kunye nomsebenzi wokuxhunywa kwi-grid/okanye ukuzimela
Ukuphumeza umgomoIqondo lobushushu elifunekayo, isiphumo, ixesha lokuqhubeka kunye nendawo yokulinganisa

Impendulo yokuqala kufuneka ichaze ikhabhathi yokuqala, ubungqina bamaqondo obushushu obusafunyanwanga, kunye nemisebenzi yolungiso ephantsi kwekhontrakthi.

Imibuzo Ebuzwa Rhoqo

Sebenzisa iqondo lobushushu elingena kwisixhobo njengoko limiselwe ngumenzi. Xhasa oku ngemeko yendawo, ukuchanabeka kwelanga, umgama phakathi kweekhabhathi, imithombo yobushushu ekufutshane kunye novavanyo lokujikeleziswa kwakhona komoya.

Hayi. Umda uchaza imida yokusebenza evumelekileyo. Ngenxa yokuba i-Energon ithi mandla ayancitshiswa ngaphezulu kwe-45°C, isicelo sisadinga i-kW okanye i-kVA ekhoyo kwi-50°C nakwi-55°C.

Ukwehla koxinzelelo lwesihluzo kuyenyuka kwaye ukuhamba komoya kunokuhla. Iifeni zinokutsala amandla ongezelelweyo ngelixa ubushushu bangaphakathi bunyuka, nto leyo ekhokelela kwisilumkiso, ukuncitshiswa kwamandla okanye ukuvalwa phantsi kwelogiki yokulawula evunyiweyo.

Umjikelo wamanzi ulawula ubushushu kwicala lebhetri, ngelixa inkqubo isala ubushushu emoyeni. Hlola kwaye ucoce i-heat exchanger, i-radiator, iifeni kunye neendawo ezivelileyo ezikhupha ubushushu.

I-125 kVA ngamandla abonakalayo. I-kW esebenzayo efumanekayo ixhomekeke kwifactor yamandla, kumthwalo we-reactive, kubushushu, nakwikhava yomthamo evunyiweyo ye-PCS.

Cela amandla okutshaja nokukhupha umbane kumaqondo obushushu angama-25°C, 40°C, 45°C, 50°C kunye ne-55°C. Dibanisa onke amanqaku nexesha lokuqhubeka, ifaktori yamandla, ukusetyenziswa kwenkxaso-mandla, imida yokulinganisa kunye nelojiki yokuchacha.

I-AC i-kW, i-kVA, i-power factor, i-DC current, i-SOC, imida kunye nokusasazeka kweqondo lobushushu lwe-cell, imeko yokupholisa, amandla oncedo, ii-alamu, iziganeko zokunciphisa umthwalo kunye neelogi zantlandlolo ezine-timestamp.

I-SAT iqinisekisa imeko efakiweyo: ubushushu bokwenene obungena, imeko yelanga, isithuba esikhululekileyo sekhabhathi, imithombo yobushushu ekufutshane, imeko yesihluzo, ukusebenza kokukhupha ubushushu kunye nedatha yomlinganiselo wasekhaya.

Qala nge-ESSA xa ubushushu obungenayo busaphakathi kwe-0–45°C, umthwalo ulingana ne-100 kW AC kwaye umsebenzisi unokugcina iifiltha, iifeni kunye nendlela yokuhamba komoya zilungeleka lula.

Hlola i-Energon xa ubushushu bayo bungena okanye budlula i-45°C, xa umthwalo usebenza ixesha elide, okanye xa indlela yokupholisa i-battery ngobushushu idinga ukupholiswa ngelaphu. Yamkela umphumo wayo ngokwe-curve yokunciphisa amandla esayinwe kunye nerekhodi yovavanyo olucetyiweyo.

I-Energon 261 yeyona MegSolid isisiseko sokuqala ifanelekileyo kuba uluhlu lwayo lokusebenza olupapashiweyo lufikelela kwi-55°C, kunye nokuncitshiswa kwamandla ngaphezulu kwe-45°C. Ukukhetha kokugqibela kusekelwe kwinto efunekayo ekuphumezeni, ixesha elithathwayo kunye nobushushu obulinganisiweyo bokungenisa kwizixhobo.

Thelekisa iinkqubo zombini kumazinga obushushu okufaka afanayo, umsebenzi oqhubekayo, ifactoramandla kunye neemeko zenkonzo yothuli. Funa iigrafu zemveliso xa kuthelekiswa nobushushu, idatha yenkxaso yokupholisa, ulwahlulo lwe-alam, imisebenzi yolungiso kunye neerekhodi ze-FAT/SAT ezingqinisiweyo.

Thumela indawo yeprojekthi, imeko yoyilo lwendalo engqongileyo, iqondo lobushushu elingeneyo elilinganisiweyo okanye elimodelweyo, ukuchanabeka kwelanga, iprofayili yomthwalo we-kW ne-kVA, ixesha lokusebenza ngomthwalo opheleleyo, ifaktha yamandla, usukelo lwamandla asebenzisekayo, imeko yothuli kunye nobuchule bokugcina.

I-ESSA0100B-0215 ipapasha uluhlu lobushushu bokusebenza olusuka kwi-0 ukuya kwi-45°C. Ukuphononongwa kweprojekthi kufuneka kwakhona kuqinisekise ubushushu obungenayo kwizixhobo, umphumo oqhubekayo, ukuhamba komoya kunye neemeko zenkonzo yesihluzo.

I-Energon 261 ipapasha ukusebenza phakathi kwe -20–55°C kwaye ichaza ukuncitshiswa kwamandla ngaphezulu kwe 45°C. Isiphumo seprojekthi esamkelweyo kufuneka silandele ikhwathi lobushushu ekhutshwe ngumenzi.

Hayi. Iidilesi ze-IP54 zikhusela isingxobo kwizinto eziqinileyo namanzi ngokwe-IEC 60529. Ukuphuma okupheleleyo, ukuncitshiswa kwamandla ngenxa yobushushu, ukuxinana luthuli kunye nokugcinwa ukupholisa kufuna ubungqina obahlukileyo bemveliso kunye neprojekthi.

IMegSolid (Hong Kong) Limited igxile kuphando nophuhliso, uyilo kunye nokubonelela ngeenkqubo zokugcina amandla ezikumgangatho ophezulu. Ngalo mava obuchwepheshe esinawo emva kweminyaka elishumi, sinikezela nge-ESS yekhabhathi yangaphandle eyenziwe ngokweemfuno zomthengi, ii-inverters zasekhaya kunye nezisombululo zamandla eziphathwayo kubathengi behlabathi jikelele.
WhatsApp/Wechat: +852 59811073

Fumana isisombululo sakho seMegSolid sokugcina amandla kwiiyure ezingama-24.

Ngqo kumvelisi weebhetri ze-solid-state. Fumana isiphakamiso se-ESS esenziwe ngokweemfuno zakho, uhlalutyo lwe-ROI, kunye nesindululo senkqubo kwiqela lethu lobunjineli.

Into Oza Kuyifumana

Ityelelwe ehlabathini lonke:

UL, IEC, UN38.3, China Classification Society, GB36276-2023, RoHS