This G2S-C single-phase energy storage inverter is part of the REVO residential energy storage inverter series. It supports on-grid/off-grid AC coupling, three-phase connection and parallel operation of multiple units. Equipped with intelligent load management and remote BMS upgrade functions, it is available in multiple versions including models without color screen, with color screen and with generator input. With a power range from 4.5kW to 9kW, it is well-suited for household energy storage applications.
IP65
Ingress protection
LCD
Display
<3%
THDi
Rated grid voltage (V)
230
Grid voltage range (V)
176~270
Grid input voltage (V)
230
Rated grid frequency (Hz)
PV input data
Our Core Values
PV input data
Model
R3KL1DA-G2S-C | R3K6L1DA-G2S-C | R4KL1DA-G2S-C | R4K6L1DA-G2S-C | R5KL1DA-G2S-C | R6KL1DA-G2S-C
Max. PV input power (kW)
4.5 | 5.4 | 6 | 6.9 | 7.5 | 9
Max. PV input voltage (V)
550
Start-up voltage (V)
100
MPPT voltage range (V)
100~430
Rated PV input voltage (V)
360
No. of MPPT trackers
2
No. of strings per MPPT tracker
1/1
Max. input current per MPPT (A)
16/16
Max. short-circuit current per MPPT (A)
24/24
Battery input data
Battery type
Lithium-ion / Lead-acid
Max. charge / discharge power (kW)
40~58
Battery voltage range (V)
40~58
Rated battery voltage (V)
48
Max. charging / discharging current (A)
60/60 | 72/72 | 80/80 | 92/92 | 100/100 | 120/120
Rated charge / discharge current (A)
60/60 | 72/72 | 80/80 | 92/92 | 100/100 | 120/120
Battery charging strategy
Self-adaption to BMS
BMS communication
CAN
AC output data (grid side)
Rated output power (kW)
3 | 3.68 | 4 | 4.6 | 5 | 6
Max. apparent output power (kVA)
3.3 | 3.68 | 4.4 | 4.6 | 5 | 6.6
Max. apparent input power(kVA)
3.3 | 3.68 | 4.4 | 4.6 | 5 | 6.6
Grid frequency range(Hz)
47~61
Rated output current (A)
13 | 16 | 17.4 | 20 | 21.7 | 26.1
Max. AC output current (A)
14.3 | 16 | 19.1 | 20 | 21.7 | 28.7
Max. apparent input current (A)
14.3 | 16 | 19.1 | 20 | 21.7 | 28.7
Power factor
>1 (0.8 leading ~ 0.8 lagging)
Max. grid passthrough current(A)
19.56 | 24 | 26.08 | 30 | 32.6 | 39.1
Grid type
L+N+PE
AC output data (back-up)
Rated output power (kW)
3 | 3.68 | 4 | 4.6 | 5 | 6
Max. apparent output power (kVA)
3.3 | 3.68 | 4.4 | 4.6 | 5 | 6.6
Rated output voltage (V)
230
Rated output frequency (Hz)
50/60
Rated output current (A)
13 | 16 | 17.4 | 20 | 21.7 | 26.1
Max. AC output current (A)
14.3 | 16 | 19.1 | 20 | 21.7 | 28.7
Peak output power
≥110%, 10mins; ≥120%, 1min; ≥130%, 1s; ≥150%, 100ms
Back-up switch time (ms)
<20
THDu