This G2S-C single-phase energy storage inverter is part of the REVO residential energy storage inverter series. It supports on-grid/off-grid AC coupling, three-phase connection and parallel operation of multiple units. Equipped with intelligent load management and remote BMS upgrade functions, it is available in multiple versions including models without color screen, with color screen and with generator input. With a power range from 4.5kW to 9kW, it is well-suited for household energy storage applications.
IP65
حماية الدخول
LCD
Display
<3%
THDi
Rated grid voltage (V)
230
Grid voltage range (V)
176~270
Grid input voltage (V)
230
Rated grid frequency (Hz)
PV input data
قيمنا الأساسية
PV input data
نموذج
R3KL1DA-G2S-C | R3K6L1DA-G2S-C | R4KL1DA-G2S-C | R4K6L1DA-G2S-C | R5KL1DA-G2S-C | R6KL1DA-G2S-C
أقصى قدرة إدخال للطاقة الكهروضوئية (كيلوواط)
4.5 | 5.4 | 6 | 6.9 | 7.5 | 9
Max. PV input voltage (V)
550
جهد البدء (فولت)
100
نطاق جهد تتبع نقطة القدرة القصوى (فولت)
100~430
Rated PV input voltage (V)
360
عدد أجهزة التتبع MPPT
2
No. of strings per MPPT tracker
1/1
الحد الأقصى لتيار الدخل لكل وحدة MPPT (أمبير)
16/16
Max. short-circuit current per MPPT (A)
24/24
Battery input data
نوع البطارية
Lithium-ion / Lead-acid
Max. charge / discharge power (kW)
3 | 3.68 | 4 | 4.6 | 5 | 6
نطاق جهد البطارية (فولت)
40~58
Rated battery voltage (V)
48
Max. charging / discharging current (A)
60/60 | 72/72 | 80/80 | 92/92 | 100/100 | 120/120
Rated charge / discharge current (A)
60/60 | 72/72 | 80/80 | 92/92 | 100/100 | 120/120
Battery charging strategy
Self-adaption to BMS
BMS communication
CAN
AC output data (grid side)
Rated output power (kW)
3 | 3.68 | 4 | 4.6 | 5 | 6
Max. apparent output power (kVA)
3.3 | 3.68 | 4.4 | 4.6 | 5 | 6.6
Max. apparent input power(kVA)
3.3 | 3.68 | 4.4 | 4.6 | 5 | 6.6
Grid frequency range(Hz)
47~61
Rated output current (A)
13 | 16 | 17.4 | 20 | 21.7 | 26.1
الحد الأقصى لتيار الإخراج المتردد (أمبير)
14.3 | 16 | 19.1 | 20 | 21.7 | 28.7
Max. apparent input current (A)
14.3 | 16 | 19.1 | 20 | 21.7 | 28.7
Power factor
>1 (0.8 leading ~ 0.8 lagging)
Max. grid passthrough current(A)
19.56 | 24 | 26.08 | 30 | 32.6 | 39.1
Grid type
L+N+PE
AC output data (back-up)
Rated output power (kW)
3 | 3.68 | 4 | 4.6 | 5 | 6
Max. apparent output power (kVA)
3.3 | 3.68 | 4.4 | 4.6 | 5 | 6.6
Rated output voltage (V)
230
Rated output frequency (Hz)
50/60
Rated output current (A)
13 | 16 | 17.4 | 20 | 21.7 | 26.1
الحد الأقصى لتيار الإخراج المتردد (أمبير)
14.3 | 16 | 19.1 | 20 | 21.7 | 28.7
Peak output power
≥110%, 10mins; ≥120%, 1min; ≥130%, 1s; ≥150%, 100ms
Back-up switch time (ms)
<20
THDu
<3%