Energy Storage Inverters & Bidirectional PCS (3–500kW)
MegSolid manufactures three inverter and PCS families: R-series hybrid inverters — G2S-C 3–6kW residential and R30KH3–R50KH3 30–50kW three-phase 4-MPPT commercial hybrids; PMA modular rack PCS — 80–125kW, up to 98.7% efficiency; and MEGA TS isolated PCS — transformer-integrated MEGA0150TS for turnkey C&I BESS deployment.
Hybrid Solid-State Full Lineup
16–96kWh 51.2V Home Backup
215kWh–5MWh Cabinets & Containers
3–500kW Hybrid & Modular PCS
Why Choose SolidESS Energy Storage Inverters & PCS
- R-series hybrid inverters (G2S-C 3–6kW and R30KH3–R50KH3 30–50kW) and 30–500kW bidirectional PCS (PMA modular and MEGA TS isolated)
- Up to 98.7% max efficiency (PMA modular PCS) with transformerless and isolated PCS configurations
- Seamless on/off-grid backup switching, PCC zero-export control, and grid support
- Pre-configured CAN, RS485, and Modbus protocols for solid-state and LFP battery BMS
- Model-specific technical datasheets, grid-compliance certificates, and OEM/ODM support
Discuss Your Inverter & PCS Requirements
Share your grid voltage, single/three-phase setup, required power (kW), and battery voltage so our engineers can match the right hybrid inverter or PCS for you.
Parcourir nos produits de stockage d'énergie
Parcourez les systèmes de batteries et équipements de conversion disponibles. Ouvrez une fiche produit pour les spécifications du modèle, les détails de configuration et les demandes techniques.
Indice de protection contre la pénétration
IP65
Poids (kg)
73kg
Compteur
RS485
Tension nominale (V)
400
Rendement maximal
98.7%
Précision de tension
±1%
Tension nominale (V)
400
Plage de tension (V)
320~460
THDi
<3%
Indice de protection contre la pénétration
IP65
Affichage
LCD
THDi
<3%
Capacité
1 kWh
Cycles
8000
Garantie
5 ans
Indice de protection contre la pénétration
IP65
Poids (kg)
73kg
Compteur
RS485
Indice de protection contre la pénétration
IP65
Affichage
LCD
THDi
<3%
Tension nominale (V)
400
Rendement maximal
98.7%
Précision de tension
±1%
Tension nominale (V)
400
Plage de tension (V)
320~460
THDi
<3%
MegSolid Energy Storage Inverter & Bidirectional PCS Selection Matrix
As a specialized battery storage converter manufacturer, MegSolid engineers high-efficiency solid-state inverters and transformerless / isolated bidirectional power conversion systems (PCS) that maximize BESS round-trip efficiency (RTE) and grid stability.
| Series / Model | Puissance nominale en courant alternatif | DC Battery Voltage Window | Topology & Key Specs | Primary Application |
|---|---|---|---|---|
| G2S-C Series (R3KL1DA–R6KL1DA-G2S-C) | 3kW – 6kW (Single-Phase) | 40V – 58V DC (48V / 51.2V) | IP65 / < 20 ms Transfer / ≥150% Surge | Residential & Light C&I Hybrid Storage |
| R30KH3 – R50KH3 Series | 30kW – 50kW (Three-Phase) | 150V – 800V DC (Dual 80A Ports) | 4 MPPT (150–850V PV) / < 10 ms Transfer | Commercial Solar-Plus-Storage & Multi-Roof Backup |
| PMA080 / PMA0105 / PMA0125 | 80kW – 125kW (Modular Rack PCS) | 615V – 950V DC (3W+PE) | 98.7% Max Efficiency / 100% Unbalanced 400V | C&I BESS Cabinets & Unbalanced Microgrid Loads |
| MEGA0150TS / MEGA PCS Series | 150kW (165kVA Floor-Standing) | 420V – 850V DC (MEGA0150TS) | Built-In Low-Frequency Isolation Transformer / IP21 | Heavy Industrial Motors, CHP & Container BESS |
INVERTER & PCS QUESTIONS
Choose the Right Inverter or PCS
1. Quelle est la différence entre un onduleur hybride et un PCS bidirectionnel ?
Hybrid inverters typically combine solar PV inputs and battery control in one unit, while a bidirectional energy storage PCS controls power flow between the battery and AC system, with solar conversion equipment specified separately where required.
2. Which inverter and PCS power ratings does MegSolid offer?
Published rated AC outputs are 3–6 kW for REVO G2S-C, 30–50 kW for R30KH3–R50KH3, 80/105/125 kW for PCS modulaires PMA and 30–500 kW for MEGA PCS, with selection based on your load, battery voltage and required operating mode.
3. Should I choose a single-phase or three-phase hybrid inverter?
Choose a single-phase hybrid inverter or a three-phase model according to your supply voltage, load distribution and backup-circuit design, checking phase-imbalance and parallel-operation limits for the exact configuration.
4. Can these inverters and PCS work with my existing battery?
Confirm the battery's operating voltage, current limits, BMS protocol and firmware pairing using our guide de compatibilité batterie–onduleur, since matching CAN or RS485 interfaces alone does not confirm that the equipment will work together.
5. What should I check before connecting solar panels?
Check PV voltage, MPPT operating range, string current and maximum array power against the selected three-phase hybrid inverter specifications, keeping maximum PV input separate from rated AC output and confirming the solar connection design for any PCS without built-in PV inputs.
6. Can the inverter or PCS supply backup power during a grid outage?
Backup operation depends on the exact inverter or PCS model, battery and switching arrangement, so confirm critical-load power, starting demand, transfer time, grid isolation and protection requirements before specifying off-grid or emergency supply.
7. Which datasheets and certifications should I request before ordering?
Request the model-specific datasheet, applicable grid-connection certificates, battery compatibility record and warranty terms, then agree the protection and commissioning checks described in our guide technique du PCS.
8. How can I request an inverter or PCS quotation?
Share your project country, application, AC voltage and phase arrangement, required output or load list, battery specifications and any solar or backup requirements to request an inverter or PCS quotation.
9. How do I verify BMS-to-PCS communication protocol compatibility?
CAN 2.0B, RS485 and Modbus TCP are the communication protocols used across the MegSolid inverter and PCS range for closed-loop battery management system (BMS) integration. Confirm which protocols your exact inverter or PCS model and battery BMS support — including firmware, voltage window and pinout — in the model datasheet before ordering. For detailed pinouts and charge voltage matching, review our BMS-to-PCS voltage window and protocol matching guide.
10. Should I choose a transformerless PCS system or an isolated PCS for industrial motor starting?
A transformerless PCS system — such as the PMA080, PMA0105 and PMA0125 modular PCS — delivers up to 98.7% conversion efficiency for standard C&I peak shaving, whereas heavy inductive loads (pumps, compressors, and stamping presses) require high surge overload capacity. See our motor-starting PCS sizing and demand interval guide et PCC zero-export control specification guide.
DE LA SÉLECTION À LA LIVRAISON
Plan Your Inverter & PCS Configuration
01 / DÉFINIR
Share Your Electrical Requirements
Project location, supply voltage, phase arrangement, connected loads and operating modes.
02 / CHOISIR
Confirm Battery and Solar Inputs
Battery voltage, current limits, BMS protocol and PV string details where applicable.
03 / VÉRIFIER
Review Compatibility and Approvals
Model and firmware pairing, grid requirements, protection settings and acceptance tests.
04 / CONFIRMER
Confirm Supply and Support
Product model, required accessories, delivery schedule, commissioning scope and warranty terms.
Les six avantages des systèmes de stockage d'énergie à batterie à l'état solide MegSolid
Rapports d'essai des batteries et documentation de sécurité
Consultez les rapports d'essai, évaluations de transport et documents de sécurité. Notre équipe confirme les fichiers applicables à votre modèle et à votre marché de destination.
Évaluation technologique 2024 : « Leader international »
Reconnu lors d'une évaluation technologique 2024 organisée par la China Battery Industry Association.
① Quatre innovations technologiques clés :solidification in situ de l'électrolyte, membranes conductrices d'ions, revêtements de cathode ultrafins et prélithiation avec couche protectrice d'électrolyte solide.
② Performances de batterie de premier plan :densité d'énergie élevée et résultats remarquables aux essais de pénétration, de chauffe et de cyclage.
③ Brevets, recherche et validation :84 brevets d'invention délivrés · 86 publications SCI/EI · 9 normes 13 rapports d'essai tiers · 2 rapports de recherche de nouveauté · 9 références d'application
Rapport d'essai UN 38.3
Résultats des essais de sécurité au transport de la batterie du modèle couvert par le rapport.
Rapport de classification de transport
Classification de transport et conditions d'expédition du modèle de batterie concerné.






Projets de stockage d'énergie et retours d'expérience
Parcourez des exemples de projets par application, configuration et périmètre de fourniture. Partez d'exigences comparables pour lancer la discussion sur votre site.
Projet de stockage par batteries pour une usine de roulements
Renhe Machinery Bearings. Lieu : Shaoxing. Configuration : 900 kW / 1 940 kWh. Objectif : décalage des pointes de charge et secours d'urgence.
Projet de stockage par batteries pour une usine électrique
Yongyao Electric. Lieu : Xuancheng. Configuration : 200 kW / 450 kWh. Objectif : réduire les coûts de pointe et soutenir une alimentation de production stable.
Projet de stockage par batteries pour galvanoplastie
Northgate Electroplating. Lieu : Ningbo. Configuration : 200 kW / 430 kWh. Objectif : réduire les coûts de pointe et stabiliser la tension au démarrage des équipements.
Projet de stockage par batteries pour une usine de galvanoplastie
Beilun Electroplating. Lieu : Ningbo. Configuration : 500 kW / 1 140 kWh. Objectif : gérer les charges de production soudaines, réduire les coûts de pointe et limiter les arrêts dus aux fluctuations du réseau.
Projet de stockage par batteries côté usine
Newroute Intelligence. Lieu : Ningbo. Configuration : 200 kW / 430 kWh. Stockage côté usine avec armoires en parallèle.
Projet de stockage par batteries côté réseau
Longquan Phase I. Lieu : Longquan, Lishui, Zhejiang. Configuration : 100 MW / 200 MWh. Objectif : régulation de fréquence, écrêtage et intégration des énergies renouvelables.